Post on 29-Mar-2016
description
Figure 1
Modified Early Warning Score (MEWS)
> 101.30 95.10 –101.20
< 95.00Temperature(F)
>200101 - 19981 - 10071 - 80< 70Systolic Blood Pressure(mmHg)
> 130111 - 129101 - 11051 - 10041 - 50< 40Heart Rate(Beats/min)
> 3021 - 2915 - 209 - 14< 8Respiratory Rate (breaths/min)
Unrespon-sive
Respond to pain
Drowsy/ Respond to voice or newly confused
AlertConfused or
agitated
Central Nervous System (CNS)-
Level of Consciousness
3210123Score
References: www.ihi.org/NR/rdonlyres/CA50FB2D-9C5E-4937-8A5A-F1740A0CAA24/0/NewI retrieved 4/3/2011Maupin,J.M., Roth, D.J. & Krapes, J.M. “Use of the Modified Early Warning Score Decreases Code Blue Events” (Dec 2009). The Joint Commission Journal on Quality and Patient Safety. Vol 35(12) p. 598-603Rees, R.E. “Early Warning Scores”. (2003) Update in Anesthesia (issue 17; Article 10)Adapted (new material added to CNS-Level of Consciousness line) from Subbe, C.P. et all: (Oct. 2001). Validation of a modified early warning score in medical admissions. QJM. 94: 521-526.