MARCUS - ElekNet...VA 50 Primary (Volts) 120 / 240 Secondary (Volts) 12 / 24 Input /Output Amps 0.42...

Post on 20-Aug-2021

5 views 0 download

Transcript of MARCUS - ElekNet...VA 50 Primary (Volts) 120 / 240 Secondary (Volts) 12 / 24 Input /Output Amps 0.42...

VA 50

Primary (Volts) 120 / 240

Secondary (Volts) 12 / 24

Input /Output Amps 0.42 , 0.21 / 4.17 , 2.08

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 50 / 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB50A

Notes:

H1-H4

120

240

INTERCONNECT:

H1-H3 AND H2-H4

H2-H3

VOLTS

12

24

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

H1-H4

X1-X4

CONNECTION DIAGRAM

H4 H1

X1 X3

X2 X4

H2H3

0V

0V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.25

1.05.3 x 15.9

3.753.00

67.3

2.502.25

95.3 63.557.2

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

50

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: Info@marcustransformer.com

VA 50

Primary (Volts) 120 / 240

Secondary (Volts) 120 / 240

Input /Output Amps 0.42 , 0.21 / 0.42 , 0.21

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 50 / 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB50B

Notes:

H1-H4

120

240

INTERCONNECT:

H1-H3 AND H2-H4

H2-H3

VOLTS

120

240

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

H1-H4

X1-X4

CONNECTION DIAGRAM

H4 H1

X1 X3

X2 X4

H2H3

0V

0V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.25

1.05.3 x 15.9

3.753.00

67.3

2.502.25

95.3 63.557.2

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

50

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: Info@marcustransformer.com

VA 50

Primary (Volts) 208 / 416

Secondary (Volts) 12 / 24

Input /Output Amps 0.24 , 0.12 / 4.16 , 2.08

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 50 / 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB50C

Notes:

H1-H4

208

416

INTERCONNECT:

H1-H3 AND H2-H4

H2-H3

VOLTS

12

24

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

H1-H4

X1-X4

CONNECTION DIAGRAM

H4 H1

X1 X3

X2 X4

H2H3

0V

0V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.25

1.05.3 x 15.9

3.753.00

67.3

2.502.25

95.3 63.557.2

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

50

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: Info@marcustransformer.com

VA 50

Primary (Volts) 208 / 416

Secondary (Volts) 120 / 240

Input /Output Amps 0.24 , 0.12 / 0.42 , 0.21

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 50 / 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB50D

Notes:

H1-H4

208

416

INTERCONNECT:

H1-H3 AND H2-H4

H2-H3

VOLTS

120

240

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

H1-H4

X1-X4

CONNECTION DIAGRAM

H4 H1

X1 X3

X2 X4

H2H3

0V

0V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.25

1.05.3 x 15.9

3.753.00

67.3

2.502.25

95.3 63.557.2

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

50

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: Info@marcustransformer.com

VA 50

Primary (Volts) 240 / 480

Secondary (Volts) 120 / 240

Input /Output Amps 0.21, 0.10 / 0.42 , 0.21

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB50E

Notes:

H1-H4240

480

INTERCONNECT:

H1-H3 AND H2-H4

H2-H3

VOLTS

120

240

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

H1-H4

X1-X4

CONNECTION DIAGRAM

H4 H1

X1 X3

X2 X4

H2H3

0V

0V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.25

1.05.3 x 15.9

3.753.00

67.3

2.502.25

95.3 63.557.2

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

50

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: Info@marcustransformer.com

VA 50

Primary (Volts) 480

Secondary (Volts) 12 / 24

Input /Output Amps 0.10 / 4.17 , 2.08

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB50F

Notes:

H1-H2480

VOLTS

12

24

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

X1-X4

12/24 X2-X3 X1-X3-X4

CONNECTION DIAGRAM

H2

H1

X1 X2

0V

0V

X4X3

480 V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.25

1.05.3 x 15.9

3.753.00

67.3

2.502.25

95.3 63.557.2

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

50

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: Info@marcustransformer.com

VA 50

Primary (Volts) 277

Secondary (Volts) 120 / 240

Input /Output Amps 0.18 / 0.42 , 0.21

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB50G

Notes:

H1-H2277

VOLTS

120

240

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

X1-X4

120/240 X2-X3 X1-X3-X4

CONNECTION DIAGRAM

H2

H1

X1 X2

0V

0V

X4X3

277 V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.25

1.05.3 x 15.9

3.753.00

67.3

2.502.25

95.3 63.557.2

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

50

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: Info@marcustransformer.com

VA 50

Primary (Volts) 347 / 380

Secondary (Volts) 120 / 240

Input / Output Amps 0.14 , 0.13 / 0.42 , 0.21

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 50 / 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB50H

Notes:

H1-H2347

380

VOLTS

120

240

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

H1-H3

X1-X4

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.25

1.05.3 x 15.9

3.753.00

67.3

2.502.25

95.3 63.557.2

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

50

Pos.

Volts

CONNECTION DIAGRAM

0V

H2

H3H1

X1X2X3

0V

347 380

X4

0V

H2 H3H1

Primary Tabs

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: Info@marcustransformer.com

VA 50

Primary (Volts) 600

Secondary (Volts) 12 / 24

Input /Output Amps 0.08 / 4.17 , 2.08

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB50I

Notes:

H1-H2600

VOLTS

12

24

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

X1-X4

12/24 X2-X3 X1-X3-X4

CONNECTION DIAGRAM

H2

H1

X1 X2

0V

0V

X4X3

600 V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.25

1.05.3 x 15.9

3.753.00

67.3

2.502.25

95.3 63.557.2

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

50

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: Info@marcustransformer.com

VA 50

Primary (Volts) 600

Secondary (Volts) 120 / 240

Input /Output Amps 0.08 / 0.42 , 0.21

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB50J

Notes:

H1-H2600

VOLTS

120

240

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

X1-X4

120/240 X2-X3 X1-X3-X4

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.25

1.05.3 x 15.9

3.753.00

67.3

2.502.25

95.3 63.557.2

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

50

CONNECTION DIAGRAM

H2

H1

X1 X2

0V

0V

X4X3

600 V

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: Info@marcustransformer.com

VA 50

Primary (Volts) 240 / 480

Secondary (Volts) 12 / 24

Input /Output Amps 0.21 , 0.10 / 4.12 , 2.08

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB50K

Notes:

H1-H4240

480

INTERCONNECT:

H1-H3 AND H2-H4

H2-H3

VOLTS

12

24

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

H1-H4

X1-X4

CONNECTION DIAGRAM

H4 H1

X1 X3

X2 X4

H2

H3

0V

0V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.25

1.05.3 x 15.9

3.753.00

67.3

2.502.25

95.3 63.557.2

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

50

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: Info@marcustransformer.com

VA 50

Primary (Volts) 347 / 380

Secondary (Volts) 12 / 24

Input / Output Amps 0.14 , 0.13 / 4.17 , 2.08

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 50 / 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB50L

Notes:

H1-H2347

380

VOLTS

12

24

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

H1-H3

X1-X4

Pos.

Volts

CONNECTION DIAGRAM

0V

H2

H3H1

X1X2X3

0V

347 380

X4

0V

H2 H3H1

Primary Tabs

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.25

1.05.3 x 15.9

3.753.00

67.3

2.502.25

95.3 63.557.2

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

50

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: Info@marcustransformer.com

VA 50

Primary (Volts) 120

Secondary (Volts) 12

Input /Output Amps 0.42 / 4.17

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB50M

Notes:

H1-H2120

CONNECT LINES TO :

VOLTS

X1-X212

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

120 V

12 V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.25

1.05.3 x 15.9

3.753.00

67.3

2.502.25

95.3 63.557.2

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

50

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: Info@marcustransformer.com

VA 50

Primary (Volts) 120

Secondary (Volts) 24

Input /Output Amps 0.42 / 2.08

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB50N

Notes:

H1-H2120

CONNECT LINES TO :

VOLTS

X1-X224

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

120 V

24 V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.25

1.05.3 x 15.9

3.753.00

67.3

2.502.25

95.3 63.557.2

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

50

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: Info@marcustransformer.com

VA 50

Primary (Volts) 208

Secondary (Volts) 120

Input /Output Amps 0.24 / 0.42

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB50O

Notes:

H1-H2208

CONNECT LINES TO :

VOLTS

X1-X2120

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

208 V

120 V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.25

1.05.3 x 15.9

3.753.00

67.3

2.502.25

95.3 63.557.2

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

50

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: Info@marcustransformer.com

VA 50

Primary (Volts) 240

Secondary (Volts) 24

Input /Output Amps 0.21 / 2.08

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB50P

Notes:

H1-H2240

CONNECT LINES TO :

VOLTS

X1-X224

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

240 V

24 V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.25

1.05.3 x 15.9

3.753.00

67.3

2.502.25

95.3 63.557.2

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

50

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: Info@marcustransformer.com

VA 50

Primary (Volts) 240

Secondary (Volts) 120

Input /Output Amps 0.21 / 0.42

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB50Q

Notes:

H1-H2240

CONNECT LINES TO :

VOLTS

X1-X2120

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

240 V

120 V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.25

1.05.3 x 15.9

3.753.00

67.3

2.502.25

95.3 63.557.2

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

50

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: Info@marcustransformer.com

VA 50

Primary (Volts) 480

Secondary (Volts) 24

Input /Output Amps 0.10 / 2.08

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB50R

Notes:

H1-H2480

CONNECT LINES TO :

VOLTS

X1-X224

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

480 V

24 V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.25

1.05.3 x 15.9

3.753.00

67.3

2.502.25

95.3 63.557.2

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

50

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: Info@marcustransformer.com

VA 50

Primary (Volts) 480

Secondary (Volts) 120

Input /Output Amps 0.10 / 0.42

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB50S

Notes:

H1-H2480

CONNECT LINES TO :

VOLTS

X1-X2120

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

480 V

120 V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.25

1.05.3 x 15.9

3.753.00

67.3

2.502.25

95.3 63.557.2

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

50

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: Info@marcustransformer.com

VA 50

Primary (Volts) 600

Secondary (Volts) 12

Input /Output Amps 0.08 / 4.17

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB50T

Notes:

H1-H2600

CONNECT LINES TO :

VOLTS

X1-X212

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.25

1.05.3 x 15.9

3.753.00

67.3

2.502.25

95.3 63.557.2

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

50

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

600 V

12 V

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: Info@marcustransformer.com

VA 50

Primary (Volts) 600

Secondary (Volts) 24

Input /Output Amps 0.08 / 2.08

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB50U

Notes:

H1-H2600

CONNECT LINES TO :

VOLTS

X1-X224

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

600 V

24 V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.25

1.05.3 x 15.9

3.753.00

67.3

2.502.25

95.3 63.557.2

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

50

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: Info@marcustransformer.com

VA 50

Primary (Volts) 600

Secondary (Volts) 120

Input /Output Amps 0.08 / 0.42

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB50V

Notes:

H1-H2600

CONNECT LINES TO :

VOLTS

X1-X2120

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

600 V

120 V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.25

1.05.3 x 15.9

3.753.00

67.3

2.502.25

95.3 63.557.2

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

50

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: Info@marcustransformer.com

VA 50

Primary (Volts) 600

Secondary (Volts) 240

Input /Output Amps 0.08 / 0.21

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB50W

Notes:

H1-H2600

CONNECT LINES TO :

VOLTS

X1-X2240

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.25

1.05.3 x 15.9

3.753.00

67.3

2.502.25

95.3 63.557.2

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

50

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

600 V

240 V

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: Info@marcustransformer.com

VA 50

Primary (Volts) 120 / 240

Secondary (Volts) 16 / 32

Input /Output Amps 0.42 , 0.21 / 3.13 , 1.56

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 50 / 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB50X

Notes:

H1-H4120

240

INTERCONNECT:

H1-H3 AND H2-H4

H2-H3

VOLTS

16

32

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

H1-H4

X1-X4

CONNECTION DIAGRAM

H4 H1

X1 X3

X2 X4

H2H3

0V

0V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.25

1.05.3 x 15.9

3.753.00

67.3

2.502.25

95.3 63.557.2

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

50

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: Info@marcustransformer.com

VA 50

Primary (Volts) 208

Secondary (Volts) 24

Input /Output Amps 0.24 / 2.08

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB50Y

Notes:

H1-H2208

CONNECT LINES TO :

VOLTS

X1-X224

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

208 V

24 V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.25

1.05.3 x 15.9

3.753.00

67.3

2.502.25

95.3 63.557.2

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

50

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: Info@marcustransformer.com