Instruments Status Usage In layout DB Stops beam?
comments
LI.BCT02
operational
Critical for machine
setup, operation,
MDs
yesYes, through
Linac2 SIS watchdog
located at several
positions along the
Linac + TRIC cards
acquisition system
LI.BCT06LA.BCT07
LT.BCT10LT.BCT20
LT.BCT30
LT.BCT40
LTB.BCT50
LTB.BCT60
BI.BCT10
Beam current transformers: intensity measurements
G Bellodi, BI- BOSS-2 meeting , 10 June 2015
Instruments Status Usage In layout DB Stops beam? comments
LT.BPM10
operational
Critical for machine
setup, operation,
MDs
yes no
During LS1 the pick ups
were replaced with
stripline detectors - compatible with Linac4.
LT.BPM20
LT.BPM30
LT.BPM40
LT.BPM50
LTB.BPM10
LTB.BPM20
LTB.BPM30
BI.BPM00
BI.BPM10
BI.BPM20
BI.BPM30
Pick-ups: Linac2 to PSB trajectory steering
G Bellodi, BI- BOSS-2 meeting , 10 June 2015
Instruments Status Usage In layout DB Stops beam?
comments
BLM1
operational MDs no no
LHC type Moveable
devicesNot in main
control system ,
BLM2
BLM3
BLM4
BLM5
BLM6
BLM7
BLMs
1, 2 low energy, in tanks, strong shielding
G Bellodi, BI- BOSS-2 meeting , 10 June 2015
Measurement Lines – LTE
Measurement Lines – LTL
Name Instrument Status Usage In layout DB Stops beam? comments
LTE.BCT15 TransfoOperational in principle MDs, setup no no
Not heavily used, most often found not working
LTE.MSG10HV?
Semgrid (fixed)
Name Instrument Status Usage In layout DB Stops beam? comments
LTS.BCT12 Transfo
Operational in principle MDs, setup no no
Not heavily used, most often found not working
LTS.BCT14 Transfo
LTS.MSGV10? Semgrid (fixed)
SPEM GM class maintenance needs follow up
G Bellodi, BI- BOSS-2 meeting , 10 June 2015
LBE
Name Instrument status usage In layout DB Stops beam?
LBE.BCT64 transo Operational
MDs, setup, debugging yes no
LBE.BCT65 Transfo Operational
LBE.BCT66 Transfo Ions / not used
LBE.MSGH10 Semgrid Operational
LBE.MSGV10 Semgrid Operational, pneumatic
LBE.MSGHV20 Semgrid Taken out
LBS
Name Instrument Status usage In layout DB Stops beam?
LBS.BCT62 Transfo Operational
MDs, setup, debugging yes no
LBS.BCT63 Transfo Ions/ not used
LBS.MSGV50 semgrid Operational, fixed with rotational
degree
G Bellodi, BI- BOSS-2 meeting , 10 June 2015
Faraday cups Name status Usage In layout DB Stops beam?
ITL.MFC01 Removed
Critical for machine setup, operation, MDs
No By default, and also in case of motor malfunction
ITL.MFC02
operationalITM.MFC01
Instruments Status Usage In layout DB Stops beam?
ITL.BCT05
operationalCritical for
machine setup, operation, MDs
no noITF.BCT15
ITF.BCT25
ITH.BCT41
Transformers
G Bellodi, BI- BOSS-2 meeting , 10 June 2015
Semgrids
Name Status Usage In layout DB Stops beam?
ITL.BSF03HV
operational Machine setup, MDs no
In case of malfunction of the motor system
ITM.BSF04HV
ITF.BSF02HV
ITF.BSG03HV
ITF.BSG04HV
ITF.BSG05HV
ITH.BSG11HV
ITH.BSG15HV
2 pick-ups are installed in the Linac3 inter-tanks: not operational but still installed – could potentially cause a vacuum leak
G Bellodi, BI- BOSS-2 meeting , 10 June 2015
Pepper pot
Pepper Pot
Control Cabinet
BEAM
Pepper pot plateMCP, PHOSPHOR
Mirror
Camera
Instruments Status Usage In layout DB Stops beam? comments
XXX (no official name yet)
Installed in April, under
commissioningmachine setup, operation, MDs no
Yes, by default or in case of malfunction
Standalone controls, to be
integrated
G Bellodi, BI- BOSS-2 meeting , 10 June 2015
LIU plans for LBS upgrade
• replacement of the spectrometer magnet (reuse identical magnets from Linac2)• exchange of the power converter (from Linac4)• controls modifications to power convertors and beam diagnostics in the part of the transfer
line in common with Linac4, to allow simpler line sharing between H- and ions.
G Bellodi, BI- BOSS-2 meeting , 10 June 2015
Layout database: Linac2: LI, LA, LTE, LTL missing from layout database - only LT, LTB, BI, LBS, LBE are present Linac3 not present in the database
Beam off: Equipment failures that could cause a prolonged beam unavailability mainly related to vacuum leaks or malfunction of pneumatic arms for intercepting devices – SIS watchdog can be modified/bypassed in case of BCT failure in order to resume operation
Criticality: Linac3 – very little instrumentation and lack of redundancy what is there is mostly critical for operation
Software: need guaranteed maintenance of BI standalone applications and work towards integration of standalone controls