Post on 05-Dec-2021
Mini-wayLS C&S Busduct System
LS C&S B
usduct System M
ini-way
2015 LS Cable & System
, Ltd. All right reserved
Feb. 2015
LS C&S B
usduct System M
ini-way
5
LS Busduct System 136 LS-ro, Dongan-gu, Anyang-si, Gyeonggi-do, 431-831, KoreaTel. 031-428-4147 Fax. 031-428-4281
G r e a t e r V a l u e T o g e t h e r
About LS Cable & System
A New Beginning as a Total Solution Provider for Electric Power and Telecommunications
History was made when LS Cable & System, the de facto holding company of LS Group, transformed into LS Holding Company in July 2008 and started as a new
total-solution provider specialized in electric power and telecommunications. It was the optimized business decision to increase management efficiency of the
constantly expending business segments and to strengthen the responsible management system to foster a new growth engine to drive our business.
By separating investment and business segments, LS Holdings was able to discover a new growth engine to propel the group into a new phase of growth. The new
change of business provided an opportunity to the subsidiary companies to focus on their own operations and to strengthen their respective business expertise,
as well as successfully enhancing the competitiveness in the industry. LS Cable & System, as the holding company, is committed to providing continued support to
the subsidiary companies, while practicing responsible management.LS Cable & System endeavor to focus on our core business while strengthening its business
expertise and competitiveness as a global company.
Since the separation from LG Electronics in 2003, LS Group has specialized in industrial energy, electronic energy, and industrial materials. Thus, LS Group has achieved specialized global competitiveness in these fields. LS Group is a parent company of 40 subsidiary companies,including LS Cable & System, LSIS, LS Nikko Copper, LS Mtron, Gaon Cable, E1 and Yesco. LS Cable & System holds the unrivaled position of the top cable maker in Korea, and it provides total solutions for electronic power and telecommunication industries.
LS Cable & System has strived to become a global leader in the industry by implementing constant innovation since the establishment of the company.
While providing high-quality solutions to help our clients, LS Cable & System is accelerating efforts to be the top player of the global cable industry by securing
the top technologies in submarine cables and superconducting cables, as well as focusing on green business. Under the company vision
’Your No.1 Creative Partner,’ LS Cable & System dedicates its best effort to deliver only the top technology and service to its clients.
Superior Essex
Global CableIncorporated
Pountek LS Global
Power equipment, Power supply & transmission, Industrial IT,Automation equipment, Electric Power Tools, RFID etc.
Components, Machinery
Supply of LPG for residential&commercial, transportation,industrial and petrochemical uses in domestic market. Import & Export of LPG etc.
LNG, CNG
Electrolytic Copper Cathode, Gold, Silver, Chemicals Product etc.
• LS Cable & System• LSIS• LS Nikko Copper• Gaon Cable
• E1• Yesco• Superior Essex
• LG Electronics• LG Chemical
• LG Display• LG Telecom
• GS Caltex• GS Engineering & Construction
• GS Retail• GS Homeshopping
Standing Tall as the Third Largest Cable Maker in the Global Cable Industry
In August 2008, LS Cable & System acquired Super Essex, the largest cable maker in North America, making LS Cable & System the third largest cable maker
in the global cable industry. By incorporating the staple product line of coils and communication wires of Superior Essex to the existing business structure
of power cables, optical fiber cables, and wires of the company, LS Cable & System has built an ideal cable product line. Securing the extensive experience
of production and distribution network of Superior Essex in the markets of North America and Europe has led to LS Cable & System’s emergence as a true
global enterprise.
Superior Essex In 1999, Superior Cable, which back then was a communication cable producer, made an acquisition of Essex Wire, a magnet wire producer,
and the combination formed Superior Essex. The company is the world’s largest maker of magnet wires and the largest maker of communication cables in
North America. The company is headquartered in Atlanta, Georgia, USA, where they manage 24 factories in a total of 9 countries, including the United States,
Canada, Mexico, Germany, the UK, Italy, and China.
Superior Essex
Global CableIncorporated
Pountek LS Global
Power equipment, Power supply & transmission, Industrial IT,Automation equipment, Electric Power Tools, RFID etc.
Components, Machinery
Supply of LPG for residential&commercial, transportation,industrial and petrochemical uses in domestic market. Import & Export of LPG etc.
LNG, CNG
Electrolytic Copper Cathode, Gold, Silver, Chemicals Product etc.
LS Cable & SystemBusduct System Solution
Apartment BuildingsAlthough the demands for more electricity for families are growing, the space for EPS area has reduced. Due to the change, the need for busducts and multi boxes have increased.
HospitalsThe stability of the power supply in the hospitals is perhaps the most vital element, because its failure could threaten the safety of patients. The Busduct system distributes larger capacity of electric power, and provides stability of the loads which make it an ideal choice to satisfy the requirements of systematization of hospital complexes and larger hospital equipments.
Marine & WindThe compact and light weight design of the busduct satisfies the demands of the clients, and comes with an outstanding quack resistance property. The busduct provides stability to the operation of the facilities through a real-time monitoring system using a temperature and power monitoring system. As the needs for renewable energy grows, the demand for our busduct has been increasing teadily.
AirportsIn order to secure the stable power supply of the airport, the busduct system provides the best customized solutions by installing high voltage busducts at the transmission, transformation and power distribution lines, and by installing low voltage busducts at the cargo, the control tower and general commercial buildings.
StadiumsThe needs for a busducts system has been growing for its benefit such as large capacity of power transmission, providing a stable power supply for various loads and an eco friendly property as well as economical quality.
BuildingsThe LS C&S Busbuct system is easy to install, and ensures large capacity of energy transmission while providing space efficiency which makes the bus duct system ideal for high-rise buildings, office buildings, data centers and apartment complexes.
PlantsThe full lineup is consisting of NSPB, CAST RESIN and SIB that can cover up to 27kv, and the lineup thus enables us to provide our clients customized designs. The system is suitable for electrical rooms and power lines, and it features a real time monitoring system using the temperature and power monitoring system.
Data CenterThe flexibility and expandability as well as easy maintenance property of the busduct system provides the best alternative to improve the existing problems of the conventional power cable system of data centers, which requires constant extension, reinstallation and capacity modification of loads.
LS Cable & System Busduct Product Line-up
Plug in Unit
Plug in Unit
Plug in Unit
Switchgear
Switchgear
Transformer
Transformer
Transformer
TR Flanged End Box
TR FlangedEnd Box
Rigid Hanger
Plug-in Box
Plug-in Box
Spring Hanger
Spring Hanger
Spring Hanger
Spring HangerPlug-in Box
Plug-in Box
Rigid Hanger
End Closer
End Closer
Outdoor
Indoor
Riser Part
Horizontal Part
2
1
2
1
3
7
6
5
4
NSPB-LV/MVAir Insulated Type/Insulated conductors separated by phase/AL, STS and Steel Housing (optional)/Indoor Type/Outdoor Type
- NSPB-LV : Designed for low voltage products below AC 1000V,and below 4000A - NSPB-MV: Designed for high voltage products below AC 27kV, and below 4000A - Suitable for plants where high stability is required.
5
Ez/Ex/Ef-waySandwich Type (PET Film, Epoxy Coating, MICA)/AL Extrusion Housing/Standard IP54/Joint Kit
- Designed for low voltage products below AC 1000V, and between 630A to 7500A. - The most widely used conventional model.
Mini-wayAir Insulated Type/AL Extrusion Housing/Standard IP54/Joint Kit
- Designed for low voltage products below AC 1000V, and between 160A and 800A.- Ideal for small distribution system with multi distribution loads (Vertical areas of buildings, data centers, assemble factories)
The LS Cable & System Busducts are available in a wide range of products from low current capacity LT-way (25A~63A) to large current capacity (630A~7500A), and the products enable the supply of proper capacity of power for factories and the distribution system. Our products such as the air insulated bus conducts with enhanced safety property and the cast resin busducts with resistance for high temperature, humidity and dusty environment will satisfy various application needs and provide a customized engineering service.
MS/Wind-wayAir Insulated Type/ Compact NSPB Type / One-Bolting TypeDesigned for low voltage products below AC 1000V, and between 1000A and 5000A
- A Hybrid incorporating NSPB and sandwich type - Ideal for ships, wind towers and chemical plants where stability is required.
LT-wayFlat Wire Type/Copper Conductor with PVC Extruded Insulation/AL Extrusion Housing/Various Plug Types/Joint Brush (It can be installed with a live wire.)
- Designed for low voltage products below AC 690V, and between 25A and 63A - Suitable for Light bulbs, FFU and distribution for small equipments
SIBEpoxy Vacuum impregnated insulation Products/Suitable for phase separation system
- Designed for high voltage products below AC 27kV and below 7500A- Small space , bending area- Suitable for high voltage products.
1
2
3
4
CR-LV/MV- Cast Resin Type/IP 68/Epoxy Molding between Conductors- CR-LV: Designed for low voltage products below AC 1000V, and between 630A and7500A.- CR-MV: Designed for high voltage products below AC 27KV, and below 5000A.- The most safe bus duct suitable for plants where high stability is required.
6
7
Why Busduct?
The compact design of the busduct system provides high space efficiency at up to 50% compared to the cables. While cables require larger space to install multi lines as well as additional space for coiling areas, the busducts use proper fittings to maximize space efficiency.
Compact
BusductCable
Pulling and cable tray installation for cables can be difficult, and requires a longer construction period, therefore increases the cost. On the other hand, the busducts use a simple installation method to connect specific length of products, which requires a shorter installation period, and is economically friendly.
Easy InstallationLabor Hours
0.2 0.6 1.0 1.4 1.8 2.2 2.6 3.0 3.4 3.8
800
1000
1500
2000
2500
3000
4000
Ampere
When supplying power using cables, each load has to be connected individually to cables which waste space, and an additional distribution panel is also required.On the other hand, busducts are separated from a single line at a plug box which simplifies the electric power system. A MCCB can be installed at the plug box to effectively shut off fault current.
• One –to-one correspondence of power supply and loads
• Additional lines are needed in case of a load change
Cable Wiring System Busduct Wiring System
ACB : Air Circuit Breaker, MCCB : Molded Case Circuit Breaker
• One –to-many correspondence of power supply for specific power supply
• Additional lines are not necessary in case of a load change
Easy Distribution of Loads
P-1
MCCBACB ACB
P-2
P-3
P-...
P-x
L-1
L-2
L-3
L-...
L-x
P-1
ACB ACB
P-2
P-3
P-...
P-x
L-1
L-2
L-3
L-...
L-x
P-1
MCCBACB ACB
P-2
P-3
P-...
P-x
L-1
L-2
L-3
L-...
L-x
P-1
ACB ACB
P-2
P-3
P-...
P-x
L-1
L-2
L-3
L-...
L-x
RST
Cable Tray
Cable
The space required reduces
by 50%
The busduct system has a high tolerance for short circuit. Its stability and reliability make it perfect for a high capacity energy transmission system.
Excellent short circuit
Cables are connected directly to electric loads using racks. Its maximum allowable current ampacity limit is 1000A, and requires additional lines for a higher current. Each line of the busduct system can transmit up to 7500A, and provides high current density.
Unlike cables, the busduct system does not require a shield, instead Busduct, the housing itself performs as a shield which enhances the features of EMC and EMI.
High current density
Outstanding features of EMC and EMI
The design of the busduct system makes it easy to detect abnormalities during installations, and ensures easy main-tenance. When humidity or dust causes a malfunction on the system, the easy-to -maintain design allows replacing only the damaged part.
Easy maintenance
The busduct system is a power distribution system and can be applied to various complex routes. The busduct system comes with various fittings such as elbow, off-set and tee, and can transmit high capacity currents without electrical and mechanical loss.
Adaptability to various installation environment with convenience
LS Cable & System has been a long-time leading Busduct provider in korea. With extensive experience and product line com-petitiveness, the company provides total solutions for each application to satisfy the needs of its clients. Using its expertise in the electronic markets of large LCD monitors and semiconductors in Korea, the company has obtained PJT sales records in 50 countries worldwide in Asia, the Middle East, CIS, and America.
Why LS Cable &System Busduct
LS Cable & System is the only global company that provides a full line-up of busducts, from low to high voltage and from low to high capacity, to satisfy every need of its clients and provide an optimized solution for each PJT.
Full Line – up
Global Top Tier
NSPB -LV/MV
SIB (MV)
Mini-way
CR-LV/MV
LT-way
Ez / Ex / Ef-way
MS/Wind-way
Unparalleled Reliability• Provides standardized design, and owns numerous certifications such as UL Certification, Quack Proof Certification, and Impact Resistance Certification• The CS team, a task force for the busduct system, provides efficient after-sale service• Safe use in hazardous zones• Manage the system using a unique temperature monitor sensor • Semi-permanent service life • Used qualified insulation such as epoxy and PET film for efficient insulation
Eco friendly• Fully recyclable• Halogen free • Does not contain RoHS 6 hazardous substance• No toxicity in fire & Fire-Retardant• Non Explosive
Total Engineering Technology• Provide the optimal design by experienced engineers• Design following analysis and inspection of CAE• Unique and exclusive design program for the busduct system• Design based on structure stability inspection • The excellent heat –radiating property of the aluminum housing, which ensures large capacity of power transmission• Low Weight & Low cost• Easy installation• Deployable where access is difficult • Automated epoxy insulation facility• Unique joint kit connections• Reduce electromagnetic• BPMS (Busduct Power Monitoring system)• BTMS (Busduct Temperature Monitoring system)
Technical Excellence
Process
• Once PJT launches, our engineer will participate to guide the clients from the initial period in order to produce the best system for our clients, and to respond quickly when the system is changed.• Our engineers from each department provide full support in design, production, installation and testing at in-bound to satisfy our clients.• We operate the CS Team, a task force for the busduct system, to make sure efficient after-sale service and maintenance service.
Total Solution
• PJT Kick Off
• Production
• Customer Service
• Product test and installation support
• PJT management
• Provide technical support for the clients• Product development
• System design
LS Cable & SystemBusduct
Total Solution
Sa
les
Design and Development Installation/ Quality / CS
Production
The Busduct Power Monitoring System
The Busduct Temperature Monitoring System
The ongoing trends of the busduct system are more than a simple power supplying system. The growing trend is; 1) the stability of the power system, 2) unmanned system,3)cost cutting, and 4)green and smart grid. While the SCADA system monitors and controls the power of the main system, the BMS monitors low loads of the sub system. The frequency of the resent electrical accidents is higher at the sub system than at the main system. Therefore, the preference for the BMS system has been increasing.
(BPMS : Busduct Power Monitoring System)
Ethernet
Smart box
Communication Unit
RS-485Ethernet OpticalCommunication
<Monitor Program>
(BTMS : Busduct Temperature Monitoring System) The busduct is a large capacity power distribution system. The insulation of the duct has to stay stable when the Joule lines occur during a power supply of the conductor. The rated current will be set by the insulation type and the temperature rises. These properties of the busduct make it possible to monitor and manage abnormalities of the system by checking the temperature of specific areas of the system.
The temperature monitoring system uses various temperature sensors such as optical fiber cable, IC electric chips and thermo-graphic cameras. Specific areas like the entire system line, joints, plug-in boxes and cable connection can be monitored at the central monitor room using various methods on request.
Mini- wayLS C&S Busduct System Catalogue
02 of 08
ContentsI. Introduction- Overview 14- Application 15
II. General Data 16
III. Component - Feeder 21- Flanged End 22- Fittings 24- Hanger 26- Plug-In Unit 27- Etc 28
IV. Technical Data - Impedance 29- Voltage Drop 29- Temperature Rise 30
V. Install Information - Joint Connection 31
VI. Certification & Specification 32
06 / 07I. Introduction
LSC&S Mini-way is an air insulation type bare conductor busduct, and designed for low currents at AC 1000V or less or between 160A and 800A. Each conductor is compounded with a class B rating insulating material (thermal class 130 oC) and using a joint kit system at the joint connections provides easy installation of feeders.The Mini-way comes with an IP54 rating and is water proof which reduces malfunction during operation caused by water leakage.
LS C&S Mini-way is suitable for lager modern structures such as apartment complexes, factories, shopping malls, and data center server rooms because of easy load distribution, extension and installation. Our highly experienced and well-trained professionals can design highly efficient products which will harmonize with surroundings and other equipments.
Safe and Efficient Distribution System
Mini-way
The light weight of LS C&S Mini-way enables easy trans-portation and installation, and employing the joint kit system provides easy installation of the feeders.
Easy Installation
LS C&S Mini-way follows the IEC standard, and has designed the cross-section, conductor support and hous-ing shape according to the regulations of temperature. Therefore it has efficient voltage drop and high short circuit strength.
Excellent Performance
Overview
14 Mini-way LS C&S-Busway System
06 / 07
Introduction
Application
• Vertical Busducts can be installed at the EPS room.• Provides better space efficiency than cables• Multi-box can be applied
Apartments and Housing etc.
• Can be applied at the low capacity lines of department stores, supermarkets and shopping malls• Provides better space efficiency than cables
Shopping Centers / Air Port etc
• Supply power to computer equipments at each rack in the server room.• Distribution boards or modular racks are not necessary.• Consist of two lines of general use and emergency use.
Data Center etc.
Mini-way LS C&S-Busway System 15
06 / 07Ⅱ. General Data
The wonderfully light weight of the Mini-way was possible due to aluminum housing, optimizing the cross sectional areas and light weight components.
Weight
The cross sectional areas of the conductor and housing profile are designed to meet the standard permissible operating temperature of IEC 61439-1 and 6. Therefore the temperature rise limit of the housing is within 55K or less of the ambient tem-perature.
Permissible Operating Temperature
Thanks to the optimum design of the conductor shapes, and predestinated space between support insulations, the Mini-way can withstand mechanical and thermal stress when a short circuit occurs.
Short Circuit Strength
• Ambient Temperature : -15 ~ 55 • Relative Humidity : 95% or below(When the service condition of the environmentdoes not meet the requirements listed above, please contact our design team.)
Service Condition
• IEC 61439-1 [(previous standard)IEC 60439-1] Power Switchgear and Controlgear Assemblies• IEC 61439-6 [(previous standard)IEC 60439-2] Busbar Trunking Systems• NSEN 60439 Busways• NEMA BU 1.1 Busways
Standard
The LS C&S Busducts acquired RoHS certification, and only uses components without hazardous substances such as lead, cadmium, mercury, chrome, PBBs and PBDEs.
Eco Friendly
Plug-in Box
Plug-in Hole
Joint Kit
16 Mini-way LS C&S-Busway System
06 / 07
Gem
eral Data
The Mini-way uses either copper conductors with conductivity over 99%, or aluminum conductors with conductivity over 61%. The connection of the conductors is tin-plated in order to reduce contact resistance and to prevent to corrosion of the connection. (A silver plated option is available.)
ConductorsThe Mini-way uses an effective heat – radiating aluminum housing profile which produces an excellent mechanical strength and heat radiation. The aluminum housing can be used as a protective conductor (PE) due to its high level conductivity and cross sectional areas.
Housing
The Mini-way uses the air insulation system. The insulation of thermal rating Class B (130oC) provides high insulation performance between conductors and between conductors and housing. In order to secure the stability of conductor support and high short circuit performance, the design is following CAE (Computer Aided Engineering) instructions.
Insulation Properties Joint KitThe Mini-way uses joint kit to connect the bus ducts. In order to ensure easy maintenance and reliability, double-headed bolts and visible labels (red tags) are used to check the application, and a disc spring allows even connection of the contact surface.(Connecting torque 800~1000kgf.cm)The joint plate of the joint kit is tin plated in order to prevent discoloration and corrosion.(A silver plated option is available.)
Feeder
Joint Kit
Joint Cover
Elbow
Mini-way LS C&S-Busway System 17
06 / 07
*Special capacity such as 4W(200%N)+100%E at [Cu 160~400A] can be produced on request.
Configration
[3W+GE] [4W+GE]
[3W+50%E] [4W+50%E]
[3W+100%E] [4W+100%E]
Ⅱ. General Data
General ConceptLSC&S Mini-way is an air insulation type bare conductor busduct, and it supports each phase with Class B rating insulating material (thermal class 130 oC). It is designed for AC 1000V or less or between 160A and 800A. It also comes with a joint kit system and standard IP54 rating.
18 Mini-way LS C&S-Busway System
06 / 07
Gem
eral Data
Grounding CapacityThe aluminum housing of the Mini-way is designed to perform as a grounding conductor within the rated current. In case 50~100% more grounding capacity is needed, an internal grounding conductor can be added without changing the existing design.
NoteThe aluminum housing itself acts as a grounding conductor and improves heat-radiation of conductors. The light weight of the Mini-way was possible thanks to the innovated design to reduce the weight.
[General Earth]
Housing
Housing
Housing
50% Earth
50% Earth
50% Earth
[50% Earth]
[100% Earth]
Mini-way LS C&S-Busway System 19
06 / 07Ⅱ. General Data
IPSolid Particle Protection Liquid Ingress Protection
1m
15cm min.
1m
No Protection
1
2
3
4
5
6
5
6
7
8
0
1
2
3
4
0
Protection against 50mmdiameter solid particles.(back of a hand)
Protection against dust.
Protection againstfalling drops of water.
Protection againstlow pressure jets of waterfrom all directions.
Protection againststrong jets of waterfrom all directions.
Protection against the effectsof immersion between15.0 centimeters and 1.0 meter.
Protection againstlonger periods of immersionunder pressure.
Protection against falling drops of water with an enclosure tilted at a 15degree angle from a vertical line
Protection againstspray sat a 60degreeangle from a vertical line
Protection againstwater splashed fromall directions.Complete protection
against dust.
Protection against 12mmsolid particles. (fingers)
Protection against 2.4mmsolid particles. (tools or thick wires)
Protection against 1mmsolid particles. (tools or most wires)
No Protection
IP Code (Degree of Protection)IP Code is an international protection degree code provided by IEC 60529(Degree of Protection Provided by Enclosure-IP Code)
NEMA STANDARD: • IP54=NEMA 12, 12K, 13 • IP55=NEMA 3, 3X, 3S, 3SX • IP66=NEMA 4.4X • IP67=NEMA 6
* As the standard differs, it is a similar substitution, nota 1:1 substitution.
The degree of protection against water of the Mini-way is a standard IP54; however, it can be adjusted up to IP65. An additional sealing using high strength silicon is also available at the joint connections between the housing and the connection cover on request.
Plating and CoatingPlatingStandard tin plating is applied at taps, plugs and connections of conductors using an electroplating method to maintain the electrical characteristics and to prevent corrosion. Silver plating is available on request.
CoatingIn order to improve the heat radiation and to prevent corrosion, as well as to fit in with the surroundings, we apply polyester-epoxy (hybrid) power coating after treating the surface. A wide range of color is available to meet the needs of our clients.
20 Mini-way LS C&S-Busway System
06 / 07
Gem
eral Data
Component
Ⅲ. Component
FeederAlthough the standard length of the Mini-way is 3 meters, it can be adjusted to the installation environment on request.
A
t
W H
A
t
W H
[3W] [4W]
Ampere(A)Dimension (mm) Weight (kg/m)
t W A H 3W 4W 4W + 50%E 4W + 100%E
AL
160
6.35
20
165
87 5.3 5.6 5.8 5.9
250 30 87 5.8 6.3 6.5 6.7
400 50 107 6.9 7.7 8.1 8.4
630 70 127 7.9 9.1 9.6 10.1
800 95 152 9.2 10.9 11.5 12.2
CU
160
6.35
20
165
87 5.8 6.3 6.8 7.2
250 30 87 6.8 7.6 8.3 9.1
400 50 107 8.1 9.4 10.6 11.9
630 50 107 12.8 15.6 16.9 18.1
800 70 127 16.2 20.1 21.9 23.7
Mini-way LS C&S-Busway System 21
06 / 07
5015
0 200
5015
0 200
5015
0 200
5015
0 200
2040
12
W
2040
12
W
A
70 A A70 A A A
AA A A
Ⅲ. Component
Flanged EndThe flanged end is connected to either a transformer or a panel. Dimension details are shown below.
[3W+GE] [4W+GE] [side]
[3W+50%E] [4W+50%E] [side]
*t : thickness of a conductor
Ampere(A)
Dimension(mm)
t w A
3W 4W
AL
160
6.35
20
100 100
250 30
400 50
630 70
800 95
CU
160
6.35
20
250 30
400 50
630 50
800 70
22 Mini-way LS C&S-Busway System
06 / 07
Component
D
B
A 50
C
C
Drilling Pattern for Flanged
Flanged End Box
500
L
B A
DC
Ampere(A)Dimension(mm)
A B C D
AL
160 200
340
70
370
250 200 70
400 220 80
630 240 100
800 265 125
Ampere(A)Dimension(mm)
A B C D
CU
160 200
340
70
370
250 200 70
400 220 80
630 220 80
800 240 100
Ampere(A)Dimension(mm)
t W A B C D L
AL
160
6.35
20 190 130
510 450 270
250 30 200 140
400 50 220 160
630 70 240 180
800 95 265 205
CU
160
6.35
20 190 130
510 450 270
250 30 200 140
400 50 220 160
630 50 220 160
800 70 240 180
Mini-way LS C&S-Busway System 23
06 / 07Ⅲ. Component
FittingsMini - way Busduct has a wide range of fittings to satisfy any layout of buildings. Elbow angles other than 90 oC are also available. Fitting designs are shown in the following figures, and they consist of the source-side and the load-side. Offset or combination elbows can be used where standard elbows are not feasible.(Dimensions for each fitting are shown in the following figures. Contact our design team for a minimum dimension.)
Elbow[Vertical] [Horizontal]
Offset[Vertical] [Horizontal]
Y
Z
Y
Y Z
X
X
Y
X
X
X
XX
YY
Z
Z
Z
Y
H
Y
Z
Y
Y Z
X
X
Y
X
X
X
XX
YY
Z
Z
Z
Y
H
Y
Z
Y
Y Z
X
X
Y
X
X
X
XX
YY
Z
Z
Z
Y
H
Y
Z
Y
Y Z
X
X
Y
X
X
X
XX
YY
Z
Z
Z
Y
HAmpere(A)Dimension(mm)
X Y
160 ~ 800 500 500
Ampere(A)Dimension(mm)
X Y Z
160 ~ 800 500 500 500
Ampere(A)Dimension(mm)
X Y Z
160 ~ 800 500 500 500
Ampere(A)Dimension(mm)
X Y
160 ~ 800 500 500
24 Mini-way LS C&S-Busway System
06 / 07
Component
Tee
Combination
[Vertical] [Horizontal]
Y
Z
Y
Y Z
X
X
Y
X
X
X
XX
YY
Z
Z
Z
Y
H
Y
Z
Y
Y Z
X
X
Y
X
X
X
XX
YY
Z
Z
Z
Y
H
Y
Z
Y
Y Z
X
X
Y
X
X
X
XX
YY
Z
Z
Z
Y
H
Ampere(A)Dimension(mm)
X Y Z
160 ~ 800 500 500 500
Ampere(A)Dimension(mm)
X Y Z
160 ~ 800 500 500 500
Ampere(A)Dimension(mm)
X Y Z
160 ~ 800 500 500 500
Ampere(A)Dimension(mm)
X Y Z
160 ~ 800 500 500 500
Ampere(A)Dimension(mm)
H_AL H_CU
160 134 134
250 144 144
400 164 164
630 184 164
800 209 184
Mini-way LS C&S-Busway System 25
06 / 07
Hanger Clamp Hanger Clamp
Hanger Rod 12Ø Hanger Rod 12Ø
Ⅲ. Component
Horizontal Hangers
[Spring Hanger]
Vertical Hangers[Rigid Hanger]
- Front Type -
- Front Type -
- Side Type -
- Side Type -
HangerBusducts installed on the ceilings, floors, walls and beams are usually supported by stud bolts, system channels, angles and channels. Various types of hangers are available depending on the installation condition or environment. (Please contact our design team for further information about hanger types and installation.)
[Flatwise] [Edgewise]
Base Channel
Base Channel
26 Mini-way LS C&S-Busway System
06 / 07
Component
Plug-in UnitThe position of the plug-in distribution location will be decided according to the installation environment and on request. The standard length of the feeders is 3 meters, and a maximum of 8 plug-in holes can be made on a 3 meter feeder. In order to secure the smooth access between the plug-in brushes and feeders, a guide pin has been attached
Attachments such as CT, TD and PT can be installed in a plug-in box to control and to supervise current, voltage and wattage remotely.
Plug-in Box
External handle
Bolt Fastening
Push Button External lever interlock
Outlet
Guide Pin Hole
Guide Pin
Various design of doors for the plug-in box is available to satisfy the demands of our clients. The available types are shown below.
Door Types of the Plug-in Box
Key Lock
Mini-way LS C&S-Busway System 27
06 / 07Ⅲ. Component
The Required Minimum Distances from a Wall for Heat Dissipation
100
100
100
200
100
100
250mm Beam
Joint Point
wall , ceilingwall , ceiling
ceiling
wall
wall
wall
wall
100
100
100
200
100
100
250mm Beam
Joint Point
wall , ceilingwall , ceiling
ceiling
wall
wall
wall
wall
100
100
100
200
100
100
250mm Beam
Joint Point
wall , ceilingwall , ceiling
ceiling
wall
wall
wall
wall
100
100
100
200
100
100
250mm Beam
Joint Point
wall , ceilingwall , ceiling
ceiling
wall
wall
wall
wall
A wall flange is used to seal the gaps produced during installation of Busducts at the walls, ceilings and floors.
Etc.Wall Flange Floor Opening
W+160
Wall Open SizeCut Out
W+60
W+10
H+1
60
H+6
0H
+10
Floor Opening SizeCut Out
W+60W30 30
H+60H
30
30
• W : The width of the product (165mm)• H : The height of the product (It is decided by a rated current.)
• W : The width of the product (165mm)• H : The height of the product (It is decided by a rated current.)
Glass Wool(out of scope)
Wall Flange Fire Foam(out of scope)
Wall,ceiling
28 Mini-way LS C&S-Busway System
06 / 07
Component
Technical Data
Actual voltage Drop = α x Vd x x Rated load currentActual load current
100mActual length of the line (m)
α(Load Constant) α = 1, concentrated load(a place such as an electrical room)
α = 0.5, Distributed load(a place such as a vertical section)
• F : Flanged End (panel connections)• P : Plug-in Unit
F F
F P P P P P
Vd = I x 3(R cosθ + X sinθ)Vd = voltage drop[V] I = rated road amperes[A] R = resistance[Ω] X = reactance[Ω] / cos = power factor / sim = reactive factor
Ⅳ. Technical Data
LS C&S Busduct has been tested under actual short circuit conditions according to IEC 61439-1 and 6 [(previous standard) IEC 60439-1 and 2] at KEMA. The result and the graph are shown below. Phase to Phase Short Circuit Ratings
Short Circuit Strength
Ampere (A) AL(kA) CU(kA)
1 sec. 3 sec. 1 sec. 3 sec. 160 10 6 10 6250 10 6 10 6400 25 15 25 15630 30 17 30 17800 40 23 40 23
Ampere(A) 10-3Ω /100m, 60Hz Voltage Drop(V/100m)
R X Z 0.7 0.8 0.9 1.0
AL
160 66.4 18.1 68.8 8.72 9.15 9.40 8.82250 32 15.1 35.4 9.15 9.42 9.44 8.13400 15.3 13.8 20.6 10.74 10.76 10.42 8.19630 6.7 8.0 10.5 11.38 11.11 10.41 7.32800 5.0 6.5 8.2 11.28 10.95 10.16 6.92
CU
160 82.2 20.9 84.8 9.17 9.56 9.73 8.75250 35.1 17.6 36.3 9.64 9.80 9.68 8.04400 17.6 13.7 22.3 11.24 11.34 11.10 8.96630 5.9 9.8 11.4 12.14 11.56 10.44 6.42800 4.4 8.1 9.2 12.25 11.57 10.33 6.05
Technical DataImpedance and Voltage DropThe formula to measure the voltage drop of a Busduct is shown below. The impedance and voltage drop values for aluminum and copper conductors are shown in the table below.The values listed are measured between the upper and middle lines at 60Hz. For a 50Hz installation, multiply the reactance (X) by 0.83.
Mini-way LS C&S-Busway System 29
06 / 07
The temperature rise limit is an important property which determines the performance of Busducts. The temperature rise limit of the Busduct is designed so that when a busduct is operated with a rated current, the temperature limit values of the housing are within 55K as specified in IEC61439-1 and 6 [(previous standard) IEC 60439-1 and 2].
Temperature Rise
Classification 1 2 3 4 5 6 7 8 9
Censer Location Connection Conductor HousingAmbient
Temperature
Temperature Rise Value 75K 79K 80K 61K 39K 32K 52K 53K 23
Ⅳ. Technical Data
Technical Data
80
70
60
50
40
30
20
10
0 1 2 3 4 5 6 7 8
5
6
7 8
1 2 3 4
Tem
pera
ture
()
Time(hr)
-Joint-
12 3
4
5
6
9
7 8
30 Mini-way LS C&S-Busway System
06 / 07
Technical Data
Intall Inform
ation
Ⅴ. Install Information
Joint Connection
Both parts should be aligned at the top and the bottom and the left and the right as well as horizontally and vertically. (This also applies to the joint connection of the horizontal and vertical ducts.) Make sure that the joint kit is not tilted. (We recommend a jig tool for the installation.)
Once the exposed head and the red tag attached to it have been cut off, they are properly connected.
Before applying the connection cover, check the space between the end block and the holes of the connection cover.
Using a torque wrench, slowly tighten the exposed bolt head of a double headed bolt. The head of the double headed bolt is designed to break off at 800~1000Kgf•cm. Continue tightening the exposed head until it breaks off.
Be sure to check the distance from the housing, and the gaps between the conductors at the kit after the installation.
Perform the last inspection of the connection. (Follow the instruction of the installation manual for additional sealing according to the IP Code)
1
3
5
2
4
6
Mini-way LS C&S-Busway System 31
06 / 07VI. Certification & Specification
Certification & Specification
Fire proof Certification Dust and Water proofCertification
ISO9001 ISO14001
KEMA Certification KEMA Certification KEMA Certification
OHSAS18001
TUV Eco Friendly Certification
32 Mini-way LS C&S-Busway System
06 / 07
Memo
Certification &
Specification
Mini-way LS C&S-Busway System 33
Beijing Office(Beijing)Tel : +86-10-5761-3166 Fax : +86-10-5761-3160
Shenzhen Office(Shenzhen)Tel. +86-755-8275-0470~1 Fax : +86-755-8275-0545
Guangzhou Office(Guangzhou)Tel. +86-20-8767-7632 Fax : +86-20-8767-7957
LS-VINA(Vietnam)Tel. +84-31-354-0141 Fax : +84-31-354-0142Production : Extra-High Voltage Cable, Medium and Low Voltage Cable, ACSR, OPGW, SCR
LSCV(Vietnam)Tel. +84-61-356-9140 Fax : +84-61-356-9148Production : Low Voltage Cable, UTP
LSCM(Malaysia)Tel. +60-4-588-9609 Fax : +60-4-588-9607Production : Magent Wire
LSCI(India)Gurgaon: Marketing & SalesTel. +91-124-428-5800~4 Fax : +91-124-428-5805
BawalTel. +91-128-426-4267Production : RF Feeder Cable, Network Solution, EHV, LV/MV, OPGW
China R&D Center Tel. +86-717-667-7777
LSCA(U.S.A.) : Marketing and SalesTel. +1-770-657-6141
LSCU(U.K.) : Marketing and SalesTel. +44-20-8899-6671 Fax : +44-20-8899-6673
LSCJ(Japan) : Marketing and SalesTel. +81-3-6205-7188 Fax : +81-3-6205-7187
LSCD(India) : Marketing and SalesTel. +91-11-41064242
LSHQ(China)Tel. +86-717-667-7777 Fax : +86-717-667-7618Production : Extra-High Voltage Cable, Medium & Low Voltage Cable,Overhead Transmission Line, Industrial Specialty Cable & System
LSCT(China)Tel : +86-22-2699-7618 Fax : +86-22-2699-7617Production : Magnet Wire
LSCW(China)Tel : +86-510-8811-9000 Fax : +86-510-8534-5341Production : Automotive Wire & Cable, Bus Duct, Electroncic Wire & Cable, Tube, ACF, Accessories for EHV Cable System
Shanghai Sales Head Office(ShangHai)Tel : +86-21-5237-6633 Fax : +86-21-5237-8996
Subsidiaries
HeadquartersTel. +82-2-2189-9114
Anyang PlantTel. +82-31-428-4114Production : Automotive Wire, Tube Components, HV Cable & Connectors, Bus Duct, Flooring System
Gumi PlantTel. +82-54-469-7114Production : Power Cable up to 500kV, OHTL, OPGW, Data Cable, RF Feeder System, Copper Rod, Magnet Wire
Indong PlantTel. +82-54-469-7763Production : Industrial Cable & Module, Optical Cable, Aluminum Materials
Donghae PlantTel. +82-33-820-3114Production : Submarine Cable, Industrial Specialty Cable
R&D CenterTel : +82-31-450-8114
Korea Operations
Abu Dhabi Office(U.A.E.)Tel : +971-2-674-8780 Fax : +971-2-674-8781
Riyadh Office(Saudi Arabia)Tel : +966-11-269-4911
Singapore Office(Singapore)Tel. +65-6342-9162~3 Fax : +65-6342-9165
Sydney Office(Australia)Tel. +61-2-9460-0255 Fax : +61-2-9460-0355
Moscow Office(Russia)Tel : +7-495-258-18-05 Fax : +7-495-258-18-06
Lima Office(Peru)Tel : +51-1-221-9786
Johannesburg Office(South Africa)Tel. +27-71-688-2028 Fax : +27-11-785-8327
Jakarta Office(Indonesia)Tel. +62-21-5795-7609~10 Fax : +62-21-5795-7608
Manila Office(Philippines)Tel: +632-547-1838 Fax : +632-955-6309
Cairo Office(Egypt)Tel. +20-2-2753-0118 Fax : +20-2-2753-0119
Branches
Yichang, China
(Shanghai, China)
(Gurgaon, India)
(New Delhi, India)
(Bawal, India)
LSCA (Atlanta, USA)
(Shenzen, China)
Global Network
s
(Beijing, China)
(Guangzhou, China)
Beijing Office(Beijing)Tel : +86-10-5761-3166 Fax : +86-10-5761-3160
Shenzhen Office(Shenzhen)Tel. +86-755-8275-0470~1 Fax : +86-755-8275-0545
Guangzhou Office(Guangzhou)Tel. +86-20-8767-7632 Fax : +86-20-8767-7957
LS-VINA(Vietnam)Tel. +84-31-354-0141 Fax : +84-31-354-0142Production : Extra-High Voltage Cable, Medium and Low Voltage Cable, ACSR, OPGW, SCR
LSCV(Vietnam)Tel. +84-61-356-9140 Fax : +84-61-356-9148Production : Low Voltage Cable, UTP
LSCM(Malaysia)Tel. +60-4-588-9609 Fax : +60-4-588-9607Production : Magent Wire
LSCI(India)Gurgaon: Marketing & SalesTel. +91-124-428-5800~4 Fax : +91-124-428-5805
BawalTel. +91-128-426-4267Production : RF Feeder Cable, Network Solution, EHV, LV/MV, OPGW
China R&D Center Tel. +86-717-667-7777
LSCA(U.S.A.) : Marketing and SalesTel. +1-770-657-6141
LSCU(U.K.) : Marketing and SalesTel. +44-20-8899-6671 Fax : +44-20-8899-6673
LSCJ(Japan) : Marketing and SalesTel. +81-3-6205-7188 Fax : +81-3-6205-7187
LSCD(India) : Marketing and SalesTel. +91-11-41064242
LSHQ(China)Tel. +86-717-667-7777 Fax : +86-717-667-7618Production : Extra-High Voltage Cable, Medium & Low Voltage Cable,Overhead Transmission Line, Industrial Specialty Cable & System
LSCT(China)Tel : +86-22-2699-7618 Fax : +86-22-2699-7617Production : Magnet Wire
LSCW(China)Tel : +86-510-8811-9000 Fax : +86-510-8534-5341Production : Automotive Wire & Cable, Bus Duct, Electroncic Wire & Cable, Tube, ACF, Accessories for EHV Cable System
Shanghai Sales Head Office(ShangHai)Tel : +86-21-5237-6633 Fax : +86-21-5237-8996
Subsidiaries
HeadquartersTel. +82-2-2189-9114
Anyang PlantTel. +82-31-428-4114Production : Automotive Wire, Tube Components, HV Cable & Connectors, Bus Duct, Flooring System
Gumi PlantTel. +82-54-469-7114Production : Power Cable up to 500kV, OHTL, OPGW, Data Cable, RF Feeder System, Copper Rod, Magnet Wire
Indong PlantTel. +82-54-469-7763Production : Industrial Cable & Module, Optical Cable, Aluminum Materials
Donghae PlantTel. +82-33-820-3114Production : Submarine Cable, Industrial Specialty Cable
R&D CenterTel : +82-31-450-8114
Korea Operations
Abu Dhabi Office(U.A.E.)Tel : +971-2-674-8780 Fax : +971-2-674-8781
Riyadh Office(Saudi Arabia)Tel : +966-11-269-4911
Singapore Office(Singapore)Tel. +65-6342-9162~3 Fax : +65-6342-9165
Sydney Office(Australia)Tel. +61-2-9460-0255 Fax : +61-2-9460-0355
Moscow Office(Russia)Tel : +7-495-258-18-05 Fax : +7-495-258-18-06
Lima Office(Peru)Tel : +51-1-221-9786
Johannesburg Office(South Africa)Tel. +27-71-688-2028 Fax : +27-11-785-8327
Jakarta Office(Indonesia)Tel. +62-21-5795-7609~10 Fax : +62-21-5795-7608
Manila Office(Philippines)Tel: +632-547-1838 Fax : +632-955-6309
Cairo Office(Egypt)Tel. +20-2-2753-0118 Fax : +20-2-2753-0119
Branches
Yichang, China
(Shanghai, China)
(Gurgaon, India)
(New Delhi, India)
(Bawal, India)
LSCA (Atlanta, USA)
(Shenzen, China)
Global Network
s
(Beijing, China)
(Guangzhou, China)
Mini-wayLS C&S Busduct System
LS C&S B
usduct System M
ini-way
2015 LS Cable & System
, Ltd. All right reserved
Feb. 2015
LS C&S B
usduct System M
ini-way
5
LS Busduct System 136 LS-ro, Dongan-gu, Anyang-si, Gyeonggi-do, 431-831, KoreaTel. 031-428-4147 Fax. 031-428-4281
G r e a t e r V a l u e T o g e t h e r