Lec 8 pile load test

Post on 06-May-2015

299 views 3 download

Tags:

description

12-4-2014

Transcript of Lec 8 pile load test

Auger Boring

Auger Bor ing

Rock Reamer

Cleaning Bucket

Rock Reamer

many tests methods have been used over the years to test the pile

In Tension Pile method a reaction frame is constructed around the test pile

the frame is anchored to reaction(Tension) piles

pile is incrementally loaded with an hydraulic jack

the test load is measured by a Load Gauge

deformation is measured with dial gauges, and surveying instruments

apply load in 10 to 15% increments, maintaining a 30 minute interval

check deformation readings immediately before and after applying load

incrementally increase load until reaching 200% of the design load

remove the load in 4 equal decrements

plot the load-settlement data the point where the load-settlement

curve crosses the failure criterion is the failure load (Qf)

Geotechnical Profile of the Site