Keygoe_SS7

Post on 06-Sep-2014

113 views 2 download

Tags:

Transcript of Keygoe_SS7

KEYGOE INSTALLATION & CONFIGURATION (SS7)

(Keygoe ver 2.2.0)

Table of contents

1.0 Introduction..................................................................................................................32.0 Keygoe Installation......................................................................................................3

2.1 Installation procedure.............................................................................................33.0 Keygoe SS7 Configuration..........................................................................................9

3.1 SS7 Configuration procedure.................................................................................94.0 Demo Program Configuration..................................................................................57

4.1 Procedure to run Demo program.........................................................................61

1

1.0 Introduction

This document will describe step by step procedure to configure Keygeo for SS7 Enviorment.

2.0 Keygoe Installation2.1 Installation procedure

To install run Keygoe V2.2.0.exe

2

Step 1

Step 2: Click “OK” to continue

Step 3

3

Step 4: Click “Next” to continue.

Step 5: Click “Next” to continue.

4

Step 6: Click “Next” to continue.

Step 7: (No need to select (I need am originally ini files) if Keygoe installed first time)

5

Step 8: Need not to select Setting Local Config.

Step 9

6

Step 10: Set the local machine IP address and click “Set” to continue.

Step 11: Click “OK” to continue.

Step 12: Click “Finish” to restart the machine.

7

3.0 Keygoe SS7 Configuration3.1 SS7 Configuration procedure

Go to C:/DJKeygoe/bin and open “ITPCFGIPSET.exe”.

8

Enable “Local IP” and Set “Config server IP” as a local IP.

Click “OK” to continue.

Go to C:/DJKeygoe/bin and open “Config.bat”, it will run and close automatically.

9

Go to C:/DJKeygoe/bin and open “DJITPConfigServer.exe”, it will run and close automatically.

10

Go to C:/DJKeygoe/bin and open “DJITPInterFaceCM.exe”.

11

Click “Settings” Icon.

Set machine IP address and click “OK” to continue.

12

If “Keygoe system (Machine IP)” is not appears in the screen then click “Refresh” icon button.

Right click “keygoe system (machine IP)” go to “Add unit (R)” and go to “DSP (D)” and choose “search DSP (S)” for adding DSP.

13

Select “Chassis 1” to precede the configuration.

14

Select “Slot1” and select “DSP0” and Set “IP address” in the same subnet of machine IP.

Click “OK” to continue.

Note: Follow the above step for adding all DSP’s.

If DSP has not shown in above “Find DSP module” screen, follow this step: Right click “keygoe system (machine IP)” and go to “Add unit (R)” and go to “DSP (D)” and choose “add directly (D)” for adding DSP directly using MAC ID.

15

Set “MAC ID”( Note down the MAC ID from back side of the E1 card) and Set “IP address” in the same subnet of machine IP.

Click “OK” to continue.

16

If the DSP’s are added correctly then the screen appears like this.

Right click “DSP” and click “Update firmware (G).

17

Click browse button and choose the file from c:\DJKeygoe\Bin.

Choose (c:\DJKeygoe\Bin) “ITP1200C_R000020EL” and click “open” to continue

Choose the file and click “Begin to load”. This screen shows the updating the DSP firmware.

18

Click “OK” to continue

DSP must be reloaded after changing any configuration on DSP module

For DSP reload Right Click on DSP > select Reload DSP.

Right click “keygoe system (machine IP)” go to “Add unit” and click “Flow (F)”.

19

Be sure that both (Keygoe application IP & Flow module IP) are same.

Click “OK” to continue.

20

If Flow module is added correctly the screen appears like this.

Right click “keygoe system (Machine IP)” and go to “Add unit” and click “Media”.

21

Be sure that both (Keygoe application IP & Media module IP) are same.

Click “OK” to continue.

22

Right click “keygoe system (Machine IP)” and go to “Add unit” and click “SS7 (S)”.

23

Be sure that both (Keygoe application IP & SS7 module IP) are same.

Click “OK” to continue.

24

Click “Start all keygoe units” icon for starting all units.

If all units are added correctly the screen appears like this.Click “Stop all keygoe units” icon for stopping the units.

25

Click “Yes” to stop all keygoe units.

This screen shows all the units are stop.

Note: If keygoe units are not come green color, follow this step’s:Go to C:/DJKeygoe/bin and open “Remove server.bat” for stopping the all units.Go to C:/DJKeygoe/bin and open “Start server.bat” for starting the all units.

26

Flow the steps for Associate “Flow, Media & SS7” units with DSP Right click “DSP” and click “Associate unit (R)”.

Add 3 “Associate module type” by Clicking “Create” button for associate the “Flow, Media & SS7”.

27

Expand all the modules.

28

Set Module type “Flow, Media & SS7” and click “Set” to continue.

Click “OK” to continue.

29

Go to “Flow0” and double click the “common Set”.

Expand “CT Bus resource configuration item”.

30

In “CT Bus resource configuration item” expand “0” and modify the “Chassis ID” from 0 to 1 and click “Set” to continue.

Click “OK” to continue.

31

Right click “Media 0” and click “Associate unit (R)”.

Add 1 “Associate module type” by clicking the “Create” button for associate with “Flow”.

32

Change “Module type” as “Flow module”.

Click “OK” to continue.

33

Right click “SS70” and click “Associate unit (R)”.

Add 1 “Associate module type” by clicking the “Create” button for associate with “Flow”.

34

Change “Module type” as “Flow module”.

Click “OK” to continue.

35

Go to C:/DJKeygoe/bin and double click the “Remove server.bat” for stop the Keygoe service.

36

Go to C:/DJKeygoe/bin and double click the “Start server.bat” for start the Keygoe service.

This screen shows all the units are working fine.

37

Expand “DSP” and expand the “Run Config” and double click the “Global Config”.

38

Expand the “Digital interface configuration”.

39

In “Digital interface configuration” expand “0” and set the Digital interface type as “E1-30(1 SS7-ISUP link)” and click “Set” to continue.

Note: Set the timeslot as per MSC configuration.

If signal timeslot is 16, config “SS7 link 1 timeslot” is 16 and “SS7 link 2 timeslot” is 0.In SS7 one link will support 20 E1’s. Make sure with MSC guys for this E1 & link.

40

For second E1, if there is no link has to define, set the Digital interface type as “E1-30(0 SS7-ISUP link)”

Click “OK” to continue.

41

Expand the “SS70” and again expand the “MTP3 parameter” then double-click the “Config mode”.

In SS7X expand the “MTP3 parameter” and double-click the “config mode”.

42

Change the “Configuration mode” from “easy mode” to “standard mode” and click “Set” to continue.

Click “OK” to continue.

Right click “SS7X” click “stop unit (S)” to stop the SS7 unit.

43

Right click “SS7X” click “start unit (S)” to start the SS7 unit.

Expand the “Parameter config” to config the Standard mode parameters.

44

Double click the “SAP parameter”.

Select the “Several source” and click “OK” to continue.

45

Change the “Link type” parameter as “CCITT” and “SPC Length” as “CCITT blue book-14bit” in ISUP parameter.

Click “OK” to continue.

46

Double click the “Route Parameter”.

Select “Several source” and click “OK” to continue.

47

By default “Switch type” is “CHINA”.

Change “Switch type” from “CHINA” to “CCITT”

48

Enable the two routes first for Inbound and Second for out bound, set the vales of DPC and OPC as per Switch then select SET button.

Click “OK” to continue.

Double click the “Link set parameter”.

49

Select “Several source” and click “OK” to continue.

Check whether “DPC” value is set or not and click “Set” to continue.

50

Click “OK” to continue.

Double click the “Link parameter”.

51

Select “Several Source” and click “OK” to continue.

Set the values corresponding to DPC, OPC, LINK type, SLC, SSF.

Then Set these parameters.

52

Right click the “SS7x” and click “stop unit (S)” to stop the SS7 unit.

Right click the “SS7x” and click “start unit (B)” to start the SS7 unit.

53

Expand “DSPx” and expand “State info” and double click the “E1port state”.

Select “several source” and click “OK” to continue.

54

Check alarm state, if “alarm” means E1 is not up. If “non-alarm” means E1 is up.“Receive signal voltage” “0dB” means E1 is up and “-12dB” means E1 is not up.

Double click the “MTP2 link state”.

55

Select “Several source” and click “OK” to continue.

Check “Link status”, it should be in “In_Service”.

If “Link status” is “Out_of_Service” or “Initial_Alignment” means link is not up.

56

For checking the link status, go to “Status & statistic” and click the “Link status” it will show the status “Link is working”.

4.0 Demo Program Configuration4.1 Procedure to run Demo program

Go to C:\DJKeygoe\Samples\XMS_Demo and open the XMS_Demo.INI.

57

Change IP address to Keygoe IP and set “Partwork” is 1 and set “PartworkmoduleID” is 1.Partwork = 0 means DSP is not enable.Partwork = 1 means DSP is enable.

PartworkmoduleID = 1 means DSP0.PartworkmoduleID = 2 means DSP1.PartworkmoduleID = 3 means DSP2.

Run XMS_Demo.exe for testing the Inbound.

58

This screen shows the inbound call is landing.

Go to C:\DJKeygoe\Samples\XMS_Demo and open the XMS_Dial.INI.

59

Change IP address to Keygoe IP and set “Partwork” is 1 and set “PartworkmoduleID” is 1.Partwork = 0 means DSP is not enable.Partwork = 1 means DSP is enable.

PartworkmoduleID = 1 means DSP0.PartworkmoduleID = 2 means DSP1.PartworkmoduleID = 3 means DSP2.

Run XMS_Dial.exe for testing the Outbound.

60

This screen shows the outbound call is landing.

61