Instrument Toolkit Training

Agenda

Training Objectives

Toolkit Overview

Toolkit Installation

Toolkit Import/Export

Examples

Summary

Training Objectives Skills

Customize the Toolkit Environment

Install the Instrument Toolkit

Utilize the Import/Export Features of the Toolkit

Use the Toolkit to Select Valid Model #’s

Perform Technical Calcs for Customers

Generate Reports for Customers

Knowledge Understand the Functionality of All the Toolkit Modules

How to Access Technical Support

Agenda

Training Objectives

Toolkit Overview

Toolkit Installation

Toolkit Import/Export

Examples

Summary

Rosemount Product Sizing & Selection Engineering Database Connectivity Technology Selection

Instrument Toolkit

Orifice Calculations Results 3051CD2A52A1AB4I5 1195S1T1S0010AA Specification Sheet Calculation Report

Process Application Data: Tag Number Process Fluid Parameters Flow Rates Pressure conditions Temperature Conditions Pipe Size/Connection Materials of Construction etc.

Product Sizing & Selection

Example: DP Transmitter w/ Primary Element

Instrument Toolkit Organization Common look and feel across modules.

Instrum ent Toolkit

P re ss u re

S O A P 2 000

P re ss u reA pp lic a tion

D P F low

S O A P 2 000

V o rtex

M a g m e ter

F lo w W iza rd

F lowA pp lic a tion

T em p era tu re

T em p era tu reA pp lic a tion

P re ss u re

S O A P 2 000

A P E X R ad a r

L ev elA pp lic a tion

T oo lbox

Customizing Toolkit

Technical SupportMarketing Contacts

DP Flow

- Joel Lemke

8605

- John Landsom

8611

- Joe Wing

8607

Vortex

- Nicole Ridder

8633

Magmeter

- Greg Gromek

8601

DP Level

- Trent Soberg

8653

Apex

- Tom Wienke

8615

- Jim Willis

8625

Temperature & Pressure

- Brad Mathiowetz

8613

- Todd Wallace

8629

Tech support for ‘module specific’ questionsAll Phones are 906-

Americas MarketingJim Tweedie 949-5161

Product ManagerSteve Rogers 828-3915

Instrument Toolkit Positioning

• Toolkit is primarily used internally to FR.• Inside & Outside sales functions• Order management

• Externally, it is a unique product that can help win more sales.

• As product matures, focus will shift external• Use it to penetrate new accounts, & win big

projects

Training Objectives Skills

Customize the Toolkit Environment

Install the Instrument Toolkit

Utilize the Import/Export Features of the Toolkit

Use the Toolkit to Select Valid Model #’s

Perform Technical Calcs for Customers

Generate Reports for Customers

Knowledge Understand the Functionality of All the Toolkit Modules

How to Access Technical Support

Agenda

Training Objectives

Toolkit Overview

Toolkit Installation

Toolkit Import/Export

Examples

Summary

Instrument Toolkit Installation Typical Installation :

Requires 90 mB of Free Disk Space Includes ALL Help Files Includes PDS Files & Acrobat Viewer Includes Technical Data Sheets

Instrument Toolkit Installation Compact Installation:

Requires 35 mB of Free Disk Space Allows user to access PDS and TDS

information from the CD-Rom Drive Requires User to possess the Installation

CD.

Agenda

Training Objectives

Toolkit Overview

Toolkit Installation

Toolkit Import/Export

Examples

Summary

Customer Need: Specify instruments from Process Data

Flow Rates Pressure Temperature Process

Tag Number Max Normal Min Max Normal Min Max Normal Min FluidFT-101 100 lbs/hr 50 lbs/hr 5 lbs/hr 1000 psi 500 psi 0 psi 200 F 100 F O F Nitrogen

FT-102 100 lbs/hr 50 lbs/hr 5 lbs/hr 1000 psi 500 psi 0 psi 200 F 100 F O F Nitrogen

FT-103 100 lbs/hr 50 lbs/hr 5 lbs/hr 1000 psi 500 psi 0 psi 200 F 100 F O F Nitrogen

FT-104 100 lbs/hr 50 lbs/hr 5 lbs/hr 1000 psi 500 psi 0 psi 200 F 100 F O F Nitrogen

STEP 1: Import process data

STEP 2: Perform sizing calculations

STEP 3: Generate model numbers & spec. sheets

STEP 4: Export data

Instrument Import/Export

Instrument Import/Export

Tagno ServiceNorm Temp

Design Temp

Temp Unit

Nor Press

Design Pres

Press Unit

Max Flow Rate

Norm Flow Rate

Min Flow Rate

Full Flow Rate

Flow Rate Unit

FT-101 UTILITY WATER 70 C 100 200 psia 3 2 0 3 USGPMFT-201 UTILITY STEAM 350 450 F 300 psig 4000 3500 0 lb/hrLT-101 DIESEL FUEL STORAGE70 C 45 200 psia TT-101 BOILER FEED WATER85 F psig WaterPT-101 UTILITY AIR 80 F 150 200 psig AirFT-SPARE UTILITY WATER 70 C 100 200 psig 3 2 0 3 USGPMFT-201 NATURAL GAS 65 100 F 150 250 psig 5000 3500 500 6000 SCFM

Customer’s Process Data

Instrument Import/Export

tag tag t1 tag tag tag f1 tag tagtagno tagmodule_id t31 temp_max temp_nor temp_min f46 temp_unit amb_temp_maxchar integer char double double double double char double

40 4 255 8 8 8 8 18 8Tagno Instrument Type Service Max Temp Norm TempMin Temp Design TempTemp Unit Max Amb Temp

Toolkit Import Header

Instrument Type

• The instrument type must be filled in manually before importing data into the toolkit.

Instrument Type ID Instrument Description

1 Pressure Transmitter

2 Magnetic Flowmeter

3 Differential Pressure Flowmeter

4 Vortex Flowmeter

5 Temperature Sensor, or Transmitter

6 Remote Seals

7 Apex Radar Level Gage

8 Coriolis Flowmeter

Training Objectives Skills

Customize the Toolkit Environment

Install the Instrument Toolkit

Utilize the Import/Export Features of the Toolkit

Use the Toolkit to Select Valid Model #’s

Perform Technical Calcs for Customers

Generate Reports for Customers

Knowledge Understand the Functionality of All the Toolkit Modules

How to Access Technical Support

Agenda

Training Objectives

Toolkit Overview

Toolkit Installation

Toolkit Import/Export

Examples

Summary

DP Transmitter Example

• Transmitter Info (3051C)– Calibrated 0 - 75 in H20– Integral Mount 3-valve coplanar manifold– Meter, FM Explosion-proof Approval– SST Wetted Matl’s

• Find a Model Number and Price• Customer gets 18% disc. on 3051

• Add a spare sensor module part

DP Transmitter Answer

• 3051CD2A02A1AM5E5S5

$1532 (List) less 18% = $1256

• 0305RC32B11 $275

• 03031-1045-0022 $780

DP Flow Example

• Multivariable Transmitter with Std. ASME Orifice

• Line: 6” sch 40• Flows: 2000 / 20,000 / 25,000 lb/hr• Fluid: Steam• Conditions: 150 psig, 400 °F• Size for 100 ”H2O @ Max Flow• SST Wetted Materials, FM Explosion Proof

– Find Models & Prices– E-mail Calc. Sheet as Excel

DP Flow Example

• 3095MA2CABA13AA000AB $2482• 1495PC060A3SAXXXXXBC $149• 1496WN060A3C $380• To E-mail

– Edit CDS & Calc Sheet– save as Excel 5.0

Vortex Example

• Process Data • Water; 0 - 500 USGPM• 120 psig, 65 °F• 6 inch line, 150# Flange (prefer a flanged meter)

• LCD Meter, CSA Explosion Proof• Need a Pulse output (1 pulse /gal)

• Will a 6” Vortex meter work?

• Find a Model & Price

• E-mail the CDS & Calc Sheet as Excel

Vortex Answers

• Yes

• 8800CF060SA1N1P1E6M5 $4013

• To E-mail – Edit CDS & Calc Sheet– save as Excel 5.0

Temperature Example

• Application Data• Smart Temperature Transmitter & RTD• Head Mount Preferred• Process Temp 32 - 120 °F• Ambient Temp in Northern US• U = 6”, 3” Union Extension• Process Connection is 3/4” NPT• Tapered 316 SST Thermowell

• Find models & Price

Temperature Example

• 0078T21C30A060T26129 $233

• 644HNA129 $512

Level Example

• Process Info• Closed vessel, balanced system• 8 ft. between taps, 10 ft. tank height,

transmitter 1 ft. below bottom tap • Min level 0 ft., max level 7.5 ft.• Fill Fluid: D.C. 200, Process S.G. = 0.85• 3” 150# flanges, SST wetted materials• flush ring with 2, ½” NPT connections

• Find the Calibration

• Model & Price for 3051 w/ FFW seals

Level Answers

• Find the Calibration• 4 mA = -89.66 in H20• 20 mA = -13.16 in H20

• 3051CD2A22A1AS2 $1479

• 1199DDB10AFFW71CAA9 $919 ea.($1838 for both)

Training Objectives Skills

Customize the Toolkit Environment

Install the Instrument Toolkit

Utilize the Import/Export Features of the Toolkit

Use the Toolkit to Select Valid Model #’s

Perform Technical Calcs for Customers

Generate Reports for Customers

Knowledge Understand the Functionality of All the Toolkit Modules

How to Access Technical Support

Agenda

Training Objectives

Toolkit Overview

Toolkit Installation

Toolkit Import/Export

Examples

Summary

Summary

The Toolkit design is solid; we have met the original performance targets.

Requirements for the Toolkit satisfy: Engineering Construction firms (E&Cs) End-Users RMT internal users

User acceptance has been positive: Easy to Use Fast

Summary Your support and feedback is integral to the

success of the Toolkit. Users can assist by documenting any Toolkit

issues and sending a cc:mail to Randy Durick, or RMD-Instrument-Toolkit, Eden Prairie.

Enhancements are dependent on feedback gathered from users. All Toolkit related

feedback should be sent via cc:mail to RMD-Instrument Toolkit, Eden Prairie mailbox

Summary

THANK YOU!!