Infrastructure Machines Monitoring System. 2 Introduction Description of the monitored...

Post on 21-Jan-2016

218 views 0 download

Tags:

Transcript of Infrastructure Machines Monitoring System. 2 Introduction Description of the monitored...

Infrastructure Machines Monitoring Infrastructure Machines Monitoring SystemSystem

2

IntroductionIntroduction

• Description of the monitored systemsDescription of the monitored systems– Ambient air monitoringAmbient air monitoring– UPS monitoringUPS monitoring

• Main featuresMain features

3

Ambient Air MonitoringAmbient Air Monitoring

• CEB, MC, WAB, NE, WE.CEB, MC, WAB, NE, WE.

• Air treatment units, cold and warm water Air treatment units, cold and warm water production and distribution devices.production and distribution devices.

• 33 Pressure sensors and 37 temperature ones 33 Pressure sensors and 37 temperature ones in water and air pipes, and in the ambient air.in water and air pipes, and in the ambient air.

• CAN CBM Ai4 ADC and Ethercan from ESD.CAN CBM Ai4 ADC and Ethercan from ESD.

• Presently 38 values are collected every 10s and Presently 38 values are collected every 10s and available for forward to the Daq (Prefix Imms)available for forward to the Daq (Prefix Imms)

4

Hardware ArchitectureHardware Architecture

Imms-server1

Ethernet/CA

Ethernet Gateway

CAN BUS

CAN DAC CAN DAC

Sensors

5

Ambient Air Monitoring (CEB)Ambient Air Monitoring (CEB)

6

Ambient Air Monitoring (MC)Ambient Air Monitoring (MC)

7

Ambient Air Monitoring (TEB)Ambient Air Monitoring (TEB)

8

Ambient Air Monitoring (WE and NE)Ambient Air Monitoring (WE and NE)

9

UPS MonitoringUPS Monitoring

CEB

MC

TB

WE

NE

UPS1,UPS2

UPS3

UPS5

UPS4

10

UPS MonitoringUPS Monitoring

• UPS goal : to maintain under constant UPS goal : to maintain under constant voltage/frequency critical devices.voltage/frequency critical devices.

• Interfacing with the ups web server (W3C) every Interfacing with the ups web server (W3C) every 10s :10s :– Presence of the ENEL network (PS)Presence of the ENEL network (PS)– Battery Charge Level (BCL),Battery Charge Level (BCL),– Percentage of charge applied (OLL),Percentage of charge applied (OLL),– Remaining Back up Time (RBT)Remaining Back up Time (RBT)

• All UPS data are collected except TB UPS1All UPS data are collected except TB UPS1

• DAQ : IMMS_Building_UPS_{PS,BCL,OLL,RBT}DAQ : IMMS_Building_UPS_{PS,BCL,OLL,RBT}

11

Main featuresMain features

• Periodical data readout and archivingPeriodical data readout and archiving

• Alarm handling,Alarm handling,

• Web based value and plot display :Web based value and plot display :imms-server1/ImmsData/MenuDisplay.php imms-server1/ImmsData/MenuDisplay.php

• SMS Interfacing to DAQ: Imms prefix.SMS Interfacing to DAQ: Imms prefix.

12

Web DisplayWeb Display

13

PLOT DISPLAYPLOT DISPLAY

14

Alarm HandlerAlarm Handler