Indoor Pollutants• Carbon monoxide (CO)• Tobacco smoke• Nitrogen oxides, hydrocarbon dust• Volatile organic compounds (VOC)• Radon• Biological Particles (bacteria, , viruses, dust mites,
cockroaches, fungi, mold, raw sewage, rotting wood)• Asbestos and Fiberglass• Lead-based paints• Water vapor
• Lifestyle (pets outside, door mats, no shoes indoors, regular cleaning)
• Careful product purchase decisions (low VOC)• Hard floor surfaces in lieu of carpeting• Sealed combustion appliances (furnace, fireplace)• House pressure balancing (jump ducts, transfer grills)
• Moisture management (humidity control)• Ventilation
– Whole house– Spot (bathrooms, kitchen, crawl spaces for radon)
• Air filtration
Indoor PollutantsHow will you deal with these?
• Air filtration
Indoor PollutantsHow will you deal with these?
• Air filtration
Indoor PollutantsHow will you deal with these?
• Air filtration
Indoor PollutantsHow will you deal with these?
Media air cleaner4” Return grille media filterElectronic air
cleaner
Efficiency at 0.3 Micron Particles100%
75%
50%
25%
0%
72%
electronicair cleaner
15%
4-inchmedia filter
1-inchmedia filter
< 1%
Indoor Pollutants
Moisture
• Moisture is the number one pollutant in homes – Need to be aware of its sources– Basic knowledge of determining moisture levels– Solving moisture problems
Dealing With Moisture
• Keep water out – Roof, plumbing, grading of ground…fix problems
• Understand that moisture will get in– Ventilation is needed
• Make sure moisture can get out– Material selection (vinyl wallpaper is a bad choice)
BPI Analyst Certification – Basic Principles of Energy
Moisture Movement Through Buildings
• Moisture in buildings can be tracked to one or more of the following (in order of importance)– Liquid flow: Roof leaks, plumbing leaks, ground
water…– Capillary seepage: Liquid water being pulled into a
material or assembly– Air movement: Carrying water vapor into or out of a
building and its cavities– Vapor diffusion: Vapor will move through solid
objects depending on the object’s permeance and the vapor pressure
Controlling Moisture …
• 1 inch of rain on 1,000 sq. ft. roof = 623 gallons • High water table• Foundation plants • Leaking water spigot
Moisture Movement
• Vapor pressure: Vapor pressure is created by different amounts of water vapor in two different air masses. Moves from high to low.
• Relative humidity: The percentage of the maximum moisture that air can hold at a given temperature– The higher the temperature of the air, the more
moisture it can hold
BPI Analyst Certification – Basic Principles of Energy
Relative Humidity• Key point: relative humidity (RH) changes as
temperature changes• When cooled enough, air at 50% RH, for
example, will hit 100% RH and the moisture in the air will condense on cool surfaces– In the winter, warm indoor air is forced out of a
building– In the summer, hot humid air is pulled into an air
conditioned space……. under this condition, there is a potential for MOLD.
Moisture Concepts• Vapor pressure: Vapor pressure is created by
different amounts of water vapor in two different air masses. Moves from high to low.
Materials Permeance • The ability of a material to restrict moisture
flow is based on its “perm rating”• Materials with a perm rating of 1 or less are
considered a “vapor retarder”
Conditioned AirU
nco
nd
itio
ned
A
ir
Air Barrier
Thermal Barrier
Structural Design• How a building fits together can give you hints
as to where there may be weaknesses– Shafts and Soffits (covered already)– Slab/Crawlspace/Basement– Framing– Porches/Garages– Bonus Rooms– Stairs– Split Levels
Understand how design features can cause weaknesses vapor barrier
• Main concern – vented crawlspace. If there is a building component (wall, shaft…) that is connected to a vented crawlspace and vented attic, high potential for problems.
Trend to build orretrofit to sealedcrawlspaces.
Slab/crawlspace/basement
Framing
• Balloon framing: Found in older homes, may have stud walls that are two stories high and usually do not have top or bottom plates. This may result in the wall being open to the basements/crawlspaces and the attic.
Framing
• Platform framing, each floor serves as a platform for the next floor. Has top and bottom plates.
Porches/Garage
• Issue with multi-story structures – Is there insulation and an air barrier at the rim joist that is hidden by the porch or garage?
Bonus Rooms
Split-Levels
Moisture Concepts• Diffusion vs. Air Movement
A Primer on Air Flow• For air to flow you need a hole and a pressure.
– No hole, no flow– No pressure, no flow
1 cubic foot 1 cubic foot
• If air is exhausted out of a building, outside air must replace it
• If you pull air into a building, inside air must be forced out
CFM50 Leakage Tests
• Provides information on how leaky the house is. – Remember, how leaky, not how much leakage.
Amount of air movement depends on pressure!• Post air sealing test can give valuable feedback
on the success of your work.• Find where the holes are.• Predictions on the impact of work.
What does a CFM50 value tell you about the house?
• CFM50 is like a 20 mile per hour wind blowing on all sides of the house.– From this value you can estimate the natural leakage
of a home (see appendix E in the BD manual).• The CFM50 value can give you a good indication of the
total size of all the holes in a home.– A tenth (remove the last digit) of the CFM50 number
is about equal to the square inches of holes in the house. 1500 CFM50 = about 150 sq. inches of holes.
Door Closure
• The average pressure that natural forces will put on a house are between 1.5 Pa (low desert) to 3 Pa (high country).
• Pressure created by door closure can be many times higher than natural pressure.
• The higher the pressures, the higher the infiltration rate.
• Room pressure tests will show if there is a problem and help determine the solution.
BPI Analyst Certification – Pressure Diagnostics
1000 CFMreturn flow
1000 CFM supply flow
100º outside
140ºAttic
Close a door and blockthe flow back to the return.
Return side will go negative.
Supply side will go positive
Room Pressure• Room WRT outside, interior door of room you are
testing closed, air handler on.
• Test every room with a door and supply or return register.
6.5
BPI Analyst Certification – Pressure Diagnostics
The following video is a time lapse infrared of a homeunder negative 3 Pa pressure for 40 minutes.
Note starting temperatures.
80.8°
80.0°
82.7°
80.7°
88.9°
87.3°
90.9°
92.5°
Temperatures after 40 minutes.8 to 12 degree increase in surface temperatures.
The pressure is getting to me!
Air Flow
Flex Duct
Air Flow
Main Body of House
Inside Bedroom
Transfer Grill
Jump Duct
House pressure balancing
House pressure balancing
Avoid negative pressuresin hot-humid climates
InfiltrationInfiltration of warm, of warm, humid air:humid air:
• Into walls• Through chases• Into rooms
CondensationCondensation
on cool surfaceson cool surfaces
The The ““Perfect House”Perfect House”
Indoor Pollutants• Water vapor
Shower (excludes towels & spillage) 1.0 pt / 10 minute shower
Clothes drying (vented indoors) 5.0 pt/ load
Combustion (unvented space heater) 7.6 pt/ gallon of kerosene
Cooking dinner (family of four) 1.2 pt(1.6 if gas cooking)
Floor mopping 1.5 pt/ 50 sq. ft.
Respiration (family of four) 0.4 pt/ hour
Desorption of materials: seasonal 6 to 17 pt/ day
New construction 10+ pt/day
Ground moisture migration Up to 100 pt/day
1.0 pint can increase the RH by about 8% in a 1,500 sq. ft. single floor home.
An average family of four can generate over six gallons of moisture per day.
Optimum Indoor Relative Humidity Levels.
• Sensible heat: The basic relationship between energy and temperatureExample: 1 Btu = 1° increase in temperature of 1 lb
of water
Sensible and Latent Heat
• Latent heat: The heat absorbed or released when a material changes phase between a solid and a liquid or between a liquid and a gas
Sensible and Latent Heat
AIR CONDITIONING
• Utilizes the properties of latent heat to move heat through a forced air distribution system– Cooling moves heat out of the house– Removes Latent heat first– Condenses water vapor back into liquid
SIZING• Over-sizing has a negative effect on energy use,
comfort, equipment life, and system costs:• Oversized systems run for a short period and do
not reach steady state efficiency (think of city vs. highway driving). Impacts both cost and life.
• Short run times mean that the air does not get mixed, causing hot spots.
• Short run times will not remove humidity, increasing comfort problems.
• Over sized equipment costs more to install.
STEADY STATE EFFICIENCIES• Mechanical devices take time to go from start
up to their peak, steady state efficiency. Some A/C units will take minutes. (SEER incorporates this start up time)
SEER
TimeStart-up
Steady State
Over sized system replaces steady state with start-up, loweringefficiency.
• Bathrooms, kitchens and utility areas should be vented to the “outside” – never to attic or crawl space.
• Exhaust vents rarely discharge rated cfm
Kitchen & Bath Moisture Control
Exhaust Vent Rules1. Size correctly• 50 cfm bathroom venting standard (*20 cfm)• 100 cfm kitchen venting standard (*25 cfm)
2. Exhaust to outdoor – never into attic3. Shortest vertical distance to outside or direct vent through wall4. Control bathroom exhaust with timer or humidistat5. Use aluminum piping without screws and taped joints
* If venting is continuous
High humidity – Poor/No Ventilation
Is the exhaust fan working properly?
Is the exhaust fan vented to the outside?
Is the fan operating long enough to remove moisture?
Clothes Dryer
Dryer Rules: Always vent to outside With mobiles vent beyond the skirting Do not vent into crawl spaces If possible direct vent to outside using smooth metal piping If elbows are needed, limit to two
Ventilation
• Three basic types of ventilation:– Infiltration– Natural ventilation (opening windows)– Mechanical ventilation
• Whole house• Spot
Infiltration vs. VentilationInfiltration vs. Ventilation
Mechanical Ventilation
• A fan that moves a measured amount of air into a house (supply), out of a house (exhaust) or both (balanced)– Ventilation systems must be selected to reduce
the potential for causing problems (mold) in the building
• Do not create positive (supply) pressures in extremely cold climates
• Do not create negative (exhaust) pressures in hot/humid climates
Do You Need Ventilation in an Existing Home?
Depends:• First, does code apply? If so, follow code.• If not (vast majority of weatherization work)
– What is in the home that needs to be vented (pollution sources)?
– How much ventilation does house already have (fans and leakage)?
Minimum Building Airflow(ASHRAE 62-89)
• American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) Standard 62-89– 0.35 Natural Air Changes Per Hour (NACH)– 15 cfm per person (15 per bedroom + 15 for Master)
* which ever is highest
0.300.25 0.35 0.40 0.45
Less Energy EfficientPoor Indoor Air Quality
Air Changes per Hour (ACH) – The volume of air in a house that is exchanged each hour with air from outside the house (ACH50 = measured at 50 Pa)ACH50 = CFM50 x 60 min/hour ÷ house volumeExample: (single story, 3 bedroom home in Phoenix)
1,500 sq ft home x 8 ft ceilings = 12,000 cu ft
Measured leakage: 1,500 cfm501,500 CFM50 x 60 ÷ 12,000 cu ft = 7.5 ACH50
ACH vs. NACH
Natural Air Changes per Hour (NACH) – A calculation of the “infiltration” rate of a home under “natural” conditions (Home Energy, “Infiltration: Just ACH50 divide by 20)NACH = ACH50 ÷ NExample:
7.5 ACH50 ÷ (1 x 1.0 x 20) = 0.375
N = # stories x shielding x climate factor
Stories = 1 story: 1.0, 1.5 story: 0.89, 2 story: 0.81
Shielding = well shield: 1.2, normal: 1.0, exposed: 0.9
Climate factor for Phoenix = 20
ACH vs. NACH
• 1,500 sf, 8 ft ceiling, single story, 3 bedroom home, Phoenix– Step 1 – 0.35 x volume / 60
• 0.35 x 12,000 / 60 = 70 CFM
– Step 2 - # occupants x 15 CFM/person• # occupants = # bedrooms + 1 = 3 + 1 = 4• 4 x 15CFM = 60 CFM
– Step 3 – choose the largest ventilation number to calculate minimum air flow at 50 Pa
• CFM50 = ventilation target x N*• 70 CFM50 x 22 = 1,540 CFM50
* Phoenix: N for single story = 22, for two story – 22 x 0.81 = 17.8
Minimum Building Airflow(BPI Calculation Method)
Ventilation (whole house)
Ventilation (whole house)
AirCycler
Motorized Damper
Thermostats with internal switch
Ventilation (whole house)
6” supply duct to return delivers about 40 - 60 cfm of ventilation (for 3 ton – 5 ton air handler)
Ventilation (whole house)
Health and Safety• Health and safety should be #1 consideration
when testing and repairing homes!• Never do anything to save energy that has a
negative impact on health and safety.• All (existing and potential) health and safety
issues should be remedied prior to, or in conjunction with, doing work.
Each individual organization needs toestablish its definition of remedied.
REQUIRE IT!