Post on 02-Oct-2021
Hybrid SolutionS
The New Generation of Fiber-to-the-Antenna Cabling
Rosenberger Asia Pacific Electronic Co., Ltd.
No.3, Anxiang Street, Block B, Tianzhu Airport Industrial Zone
Beijing, China 101300
Tel : (+86 10) 80481995
Fax : (+86 10) 80497052
Email: sales@RosenbergerAP.com
Rosenberger (Shanghai) Technology Co.,Ltd.
No. 303, Xinke Road, Qingpu Industrial Zone
Shanghai, China 201707
Tel : (+86 21) 69214567
Fax : (+86 21) 69212923
Rosenberger Asia Pacific Electronic Co., Ltd. Shanghai Division
B7, No. 509, Renqing Road, East Zone of Zhangjiang High-Tech Park
Shanghai, China 201201
Tel : (+86 21) 58995997
Fax : (+86 21) 58995594
Rosenberger Asia Pacific Electronic Co., Ltd. Dongguan Division
No.1, 1st Road of Shanglian, Jiaoshe Village, Dongkeng Town
Dongguan, Guangdong Province, China 523443
Tel : (+86 769) 82802098
Fax : (+86 769) 82802099
Rosenberger All rights reserved. 1st Edition, 2013
Please visit our website: www.RosenbergerAP.com
www.RosenbergerAP.com
Introduction01
Rosenberger HQ, Bavaria, Germany
01
A
B
C
D
E
Rosenberger Asia Pacific: A: Beijing − Headquarters, R&D,
and Production
B: Shanghai Zhangjiang − R&D
and Production
C: Shanghai Qingpu − R&D and
Production
D: India − R&D and Production
E: Dongguan − R&D and
Production
Rosenberger Hochfrequenztechnik GmbH&Co. was founded in Germany in 1958 and ranks among the leading manufacturers of high-speed interconnect solutions worldwide. To serve the continuous growth and demand of the global market, Rosenberger Asia Pacific Electronic Co., Ltd. was established in China in 1997. With its long tradition of excellence and providing creative solutions, Rosenberger Asia Pacific has excelled and earned an outstanding reputation in the Asia Pacific region.
Rosenberger Asia Pacific provides products and solutions for Telecommunication, Automotive Electronics, Information Technology, Test & Measurement, Aviation, and Medical & Industries.
A sales network covering the entire Asia Pacific region generates an annual turnover close to 200 million USD. Reliability and competitiveness are the cornerstones of this sustainable growth, resulting in long term partnerships with most of the leading companies in their respective industries.
Rosenberger Asia Pacific maintains 6 modern manufacturing and R&D base locations in Beijing, Shanghai, and Dongguan in China; and New Delhi in India, the largest of its kind in the Asia Pacific Region. Rosenberger Asia Pacific is an ISO 9001 quality system, ISO 14001 environmental system, and ISO/TS16949 automotive industry system certified company. Equipped with advanced machining, electronic plating, assembly and testing centers and staffed by a large group of more then 200 R&D engineers, Rosenberger Asia Pacific has developed first class production assembly lines and exercises stringent product and quality control.
Presently, Rosenberger Asia Pacific maintains a far reaching network of R&D, Production, Sales and Service which extends to the whole Asia Pacific and Middle East area. For over 50 years Rosenberger has established its brand all over the world. In the future, Rosenberger Asia Pacific will continue to provide excellent product solutions and services for its customers in the entire region.
02
Fiber-to-the Antenna (FTTA)02
03
Site Solutions from Rosenberger address your network connectivity needs for today and the future
There is a huge demand for high-speed data transfer in today’s global mobile telecommunication networks. Fiber-fed remote radio technology offers potential savings in both capital expenditure (CapEx) and operating expense (OpEx) reductions compared with traditional coaxial cable-based solutions.
The connectivity performance between the base station and RRU/Antenna is essential to maintaining the quality of service between the network and end-user. There are two methods of implementation: a single hybrid cable assembly (containing multiple fiber and DC power feeds) or utilizing several individual power and fiber cable feeds in parallel. Rosenberger, a professional site solutions provider, offers both to meet a variety of customer applications.
The New Generation of FTTA Cabling − Hybrid Solutions are effective in streamlining operations when replacing traditional base station equipment with RRUs or upgrading a site to support RRUs. A single hybrid cable provides multiple fiber and power conductors. This is advantageous as it consolidates space and can provide room for growth for additional RRUs. Rosenberger pre-terminated hybrid cable assemblies minimize the amount of cables running up the tower. A single hybrid cable provides several fiber and power conductors to support multiple RRUs. The flexible lightweight aluminum corrugated cable allows operators to ground the cabling system. To simplify installation, the hybrid cable outer dimension follows standard feeder dimensions (1/2”, 7/8”, or 1-1/4”) and enables use of standard feeder clamps, grounding kits.
Fiber-to-the Antenna
(FTTA)
04
EasylinkTM Hybrid Solution03
EasylinkTM Hybrid Solution is designed with slim dividers which split multi-fiber and DC cables into individual outdoor cables. The hybrid trunk cables are terminated with IP67-rated connectors. Different types of jumpers are available to allow connection between the hybrid cable and any vendor-specific hardware interface.
EasylinkTM Hybrid Solution is the best choice for operators who lease space on tower cell sites. It reduces annual leasing costs by reducing the space utilized on the tower. Plug-and-Play connections minimize installation time and require no tools.
Features and Benefits:
• Plug-and-play installation • Reduced installation costs• Reduced tower loading and leasing costs• IP67 outdoor waterproof fiber and power connectors • Flexibility to replace or upgrade RRUs by changing Jumpers
05
FTTA JumpersIP67 RDC Connector
Power JumpersIP67 Power Connector
EasylinkTM HybridIP67 Slim Divider
19" Patch Panel(optional)
EasylinkTM Hybrid Cable Assembly
EasylinkTM Hybrid
Solution
• Support three to six RRUs• IP67 compact and slim divider• Easy adjustment of length of breakout point in hybrid cable• Fiber optic cables terminated with RDC plugs; connect to vendor-specific interfaces using FTTA extension jumpers• Power cables terminated with connecters or left open-ended• Color and number coding for easy identification
Features
Specifications
Parts
Side A (RRU)Fiber: RDC plug or RRU connector
Power: open-end or connector
Side B (BTS)Fiber: trunk breakout with LC duplex
Power: open-end
Divider Aluminium, Min. Ф63mm, height 180mm
Breakout Cable Length (RRU)Fiber: Min. 0.6m (customized lengths available)
Power: Min. 0.5m (customized lengths available)
Cable Retention Force (at Divider)
Fiber breakout cable: 200N
Power breakout cable: 500N
Hybrid cable: 1000N
Temperature Range -40°C ~ +70°C
Packing Wood board drum
Hybrid Cable
Outer Diameter Nominal (mm) 27.5 ± 0.5mm (7/8" cross-section), 39 ± 0.8mm (1-1/4" cross-section)
Jacket Material LSZH, resistant to sunlight (UV)
Armored Type Corrugated aluminum
Number of Fibers 6 ~ 48
Fiber Type SM or MM
Copper Cores 4mm2 (12AWG), 6mm2 (10AWG), 10mm2 (8AWG)
Number of Conductors 6 (3 pairs), 8 (4 pairs), 10 (5 pairs), 12 (6 pairs)
Nominal Voltage Uo/U 600/1000V
Flammability IEC 60332-1
2002/95/EC(RoHS) Compliant
06
03
07
Fiber and Power Jumpers
The Rosenberger Fiber Jumpers and Power Jumpers connect RRUs to the hybrid cable assembly at the tower top. Terminated with RDC connectors, these jumpers provide convenient interconnections between the hybrid cable and RRU or other equipment.
RDC Jumpers
Power Jumper
Optical Data
Mechanical Data
Specification
Environmental Data
* Other cable size options are available upon request.
RDC Connector
Insertion Loss Max. 0.5dB
Return Loss Min. 50dB single-mode
LC / SC Connector
Insertion Loss Max. 0.3dB
Return Loss Min. 50dB single-mode
Cable Diameter 4.8mm*
Cable Minimum Bending Radius
Installation 50mm
Operation 30mm
Cable Maximum Tensile Strength
Installation 450N
Operation 300N
Cable Crush Resistance 1KN/100mm
Number of Poles 2
Conductor 4mm2 (12AWG), 6mm2 (10AWG)
Ingress Protection IP67
Jacket Material PVC
Braid Tinned copper
Temperature Range Operation -40°C ~ +85°C
Temperature Range Storage -40°C ~ +70°C
Temperature Range Installation -10°C ~ +65°C
2002/95/EC (RoHS) Compliant
04
RMCTM Hybrid
Solution
08
RMCTM Hybrid Solution
RMCTM Hybrid Solution is terminated with Rosenberger Multi-fiber Connector (RMC) which utilizes standard MPO fiber interface with additional protection to work under harsh environments. Different types of jumpers are available to allow connection between the hybrid cable and any vendor-specific hardware interface.
A single fiber optic cable breakout, located at the hybrid trunk cable divider, enables easier installation when supporting more than three RRUs.
Features and Benefits:
• Plug-and-play installation • Faster installation• Reduced tower loading and leasing costs• IP67 outdoor waterproof fiber and power connectors• No special tools required
FTTA JumpersIP67 RMC Connector
Power JumpersIP67 Power Connector
RMCTM HybridIP67 Slim Divider
19" Patch Panel(optional)
09
04 RMCTM Hybrid Cable Assembly
• Support three to six RRUs• IP67 compact and slim divider • Easy adjustment of length of breakout point in hybrid cable• Standard MPO interface, up to 24 fibers• Fiber optic cables terminated with RDC plugs; connect to vendor-specific interfaces using FTTA extension jumpers• Power cables terminated with connecters or left open-ended• Color and number coding for easy identification
Features
Specifications
Parts
Side A (RRU)Fiber: RMC plug
Power: open-end or connectorized
Side B (BTS)Fiber: trunk breakout with LC duplex
Power: open-end
Divider Aluminium, Min. Ф63mm, height 180mm
Breakout Cable Length (RRU)Fiber: Min. 0.8m (customized lengths available)
Power: Min. 0.5m (customized lengths available)
Cable Retention Force (at divider)
Fiber breakout cable: 200N
Power breakout cable: 500N
Hybrid cable: 1000N
Temperature Range -40°C ~ +70°C
Packing Wood board drum
Hybrid Cable
Outer Diameter Nominal (mm) 27.5 ± 0.5mm (7/8"cross-section), 39 ± 0.8mm (1-1/4"cross-section)
Jacket Material LSZH, resistant to sunlight (UV)
Armored Type Corrugated aluminum
Number of Fibers 6 ~ 48
Fiber Type SM or MM
Copper Cores 4mm2 (12AWG), 6mm2 (10AWG), 10mm2 (8AWG)
Number of Conductors 6 (3 pairs), 8 (4 pairs), 10 (5 pairs), 12 (6 pairs)
Nominal Voltage Uo/U 600/1000V
Flammability IEC 60332-1
2002/95/EC(RoHS) Compliant
RMCTM Hybrid
Solution
10
RMC Fiber and Power Jumpers
The Rosenberger RMC Fiber and Power Jumpers connect RRUs to the RMC hybrid cable assembly at the tower top. Terminated with a RMC connector, the fiber jumper provides quick and convenient interconnections between the RMC hybrid cable and fiber interfaces on multiple RRUs.
RMC Jumpers
Power Jumper
Optical Data
Electrical Data
Environmental Data
RMC Connector
Insertion Loss Max. 0.7dB
Return Loss Min. 50dB single-mode
LC / SC Connector
Insertion Loss Max. 0.3dB
Return Loss Min. 50dB single-mode
Breakout FO Cable Diameter 4.8mm
Cable Minimum Bending Radius
Installation 50mm
Operation 30mm
Cable Maximum Tensile Strength
Installation 450N
Operation 300N
Cable Crush Resistance 1KN/100mm
Temperature Range Operation -40°C ~ +70°C
Temperature Range Storage -40°C ~ +70°C
Temperature Range Installation -10°C ~ +65°C
2002/95/EC (RoHS) Compliant
Mechanical Data
Number of Poles 2
Conductor 4mm2 (12AWG), 6mm2 (10AWG)
Ingress Protection IP67
Jacket Material PVC
Braid Tinned copper
Traditional Hybrid Solution05
Traditional Hybrid Solution is a typical design using a hybrid cable and distribution box. The cable runs from the BBU up the tower to a weatherproof distribution box at the top. The distribution box provides the interconnection point for power and signal between the tower cable and the jumpers leading to the RRUs. The Distribution box can include over-voltage protection (OVP). A secondary distribution box at the bottom is optional.
Towers containing multiple sectors can be a supported by multiple hybrid trunks. For example, 12 RRUs can be supported with only three RRU trunk cables running up the tower.
Features and Benefits:
• Hybrid tail jumpers instead of individual fiber and power jumpers• Flexibility to replace or upgrade RRUs by changing Hybrid tail jumpers• IP67 Hybrid distribution box for fiber and power
11
Hybrid Tails
Hybrid DistributionBox (IP67)
Hybrid TrunkCable
19” Patch Panel
Traditional Hybrid Cable Assembly
Traditional Hybrid
Solution
• Support up to four RRUs• Easily grounded within the distribution box• Easy adjustment of length of breakout point in hybrid cable• Hybrid tail jumpers available to support vendor-specific interfaces• Connects to FO patch panel at base
Features
Specifications
12
Parts
Side A (box)Fiber: LC duplex connector
Power: open-end
Side B (BTS)Fiber: trunk breakout with LC duplex connector
Power: open-end
Breakout Cable Length (BTS)Fiber: 4m (customized lengths available)
Power: 4m (customized lengths available)
Temperature Range -40°C ~ +70°C
Packing Wood board drum
Hybrid Cable
Outer Diameter Nominal (mm) 27.5 ± 0.5mm (7/8" cross-section), 39 ± 0.8mm (1-1/4" cross-section)
Jacket Material LSZH, resistant to sunlight (UV)
Armored Type Corrugated aluminum
Number of Fibers up to 24
Fiber Type SM or MM
Copper Cores 4mm2 (12AWG), 6mm2 (10AWG), 10mm2 (8AWG)
Number of Conductors 8 (4 pair)
Nominal Voltage Uo/U: 600/1000V
Flammability IEC 60332-1
2002/95/EC(RoHS) Compliant
Hybrid Distribution Box05
• Flexibility to upgrade RRUs by changing jumpers, not the entire cabling system.• Designed to handle up to 4RRUs.• Provides waterproof protection to fiber and power connections• One main hybrid trunk cable entry• Four hybrid tail jumper entries• Hinged cover
Used at tower top for fiber and power distribution for RRUs. Can also be utilized at the bottom of the tower for power and fiber integration.
Features
Dimension (L x W x H) 300mm x 300mm x 130mm
Mounting Pole, wall
Material Polycarbonate
Hybrid Trunk Cable 1 (7/8" cross-section)
Hybrid Tail Jumper 4 (1/2" cross-section)
Sealing of Jumpers Multihole cable glands
IP Rating IP67
Operation Temperature -40°C ~ +85°C
Earthing Grounding cable
2002/95/EC(RoHS) Compliant
13
Hybrid Tail Jumper
Traditional Hybrid
Solution
Specifications
Parts
Side A (RRU)Fiber: LC duplex connector or vendor-specific interfaces
Power: open-end
Side B (box)Fiber: LC duplex connector
Power: open-end
Breakout Cable Length (RRU)Fiber: 0.75m (customized lengths available)
Power: 0.75m (customized lengths available)
Breakout Cable Length (box)Fiber: 0.5m
Power: 0.5m
Temperature Range -40°C ~ +70°C
Packing Plastic bag
Hybrid Cable
Outer Diameter Nominal (mm) 15.8 ± 0.5mm (1/2" cross-section)
Jacket Material LSZH, resistant to sunlight (UV)
Armored Type Corrugated aluminum
Number of Fibers 2 ~ 4
Fiber Type SM or MM
Copper Cores 4mm2 (12AWG), 6mm2 (10AWG)
Number of Conductors 2 (1 pair)
Nominal Voltage Uo/U: 600/1000V
Flammability IEC 60332-1
2002/95/EC(RoHS) Compliant
14
NSN Radio
Ericsson Radio
Huawei Radio
ASideTop
BSide
Bottom
ASideTop
BSide
Bottom
ASideTop
BSide
Bottom
Hybrid SolutionS
The New Generation of Fiber-to-the-Antenna Cabling
Rosenberger Asia Pacific Electronic Co., Ltd.
No.3, Anxiang Street, Block B, Tianzhu Airport Industrial Zone
Beijing, China 101300
Tel : (+86 10) 80481995
Fax : (+86 10) 80497052
Email: sales@RosenbergerAP.com
Rosenberger (Shanghai) Technology Co.,Ltd.
No. 303, Xinke Road, Qingpu Industrial Zone
Shanghai, China 201707
Tel : (+86 21) 69214567
Fax : (+86 21) 69212923
Rosenberger Asia Pacific Electronic Co., Ltd. Shanghai Division
B7, No. 509, Renqing Road, East Zone of Zhangjiang High-Tech Park
Shanghai, China 201201
Tel : (+86 21) 58995997
Fax : (+86 21) 58995594
Rosenberger Asia Pacific Electronic Co., Ltd. Dongguan Division
No.1, 1st Road of Shanglian, Jiaoshe Village, Dongkeng Town
Dongguan, Guangdong Province, China 523443
Tel : (+86 769) 82802098
Fax : (+86 769) 82802099
Rosenberger All rights reserved. 1st Edition, 2013
Please visit our website: www.RosenbergerAP.com
www.RosenbergerAP.com