FOR YOUR SAFETY
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, injury, or death.
- Do not store or use gasoline or other flam-mable vapors or liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS: • Donottrytolightanyappliance.• Donottouchanyelectricalswitch;donotuse
any phone in your building. • Immediatelycallyourgassupplierfroma
neighbor’sphone.Followthegassupplier’sinstructions.
• Ifyoucannotreachyourgassupplier,callthefire department.
-Installationandservicemustbeperformedbyaqualifiedinstaller,serviceagency,orthegassupplier.
POOL AND SPA/HOT TUB HEATERSH150FD, H200FD, H250FD, H300FD,
H350FD & H400FD MODELS
OWNER’S MANUAL
FOR YOUR SAFETYThisproductmustbeinstalledandservicedbyauthorizedpersonnel,qualifiedinpool/spaheaterinstallation.Improperinstallationand/oroperationcancreatecarbonmonoxidegasandfluegasesthatcancauseseriousinjury,propertydamage,ordeath.
1301640701 Rev C XXXX
HAYWARD ®
Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
�
Warnings ....................................................................................................3-6
Section I General information ........................................................................7
Section II. Consumer Operation & Maintenance ...........................................8
Using chlorinators and chemical feeders:......................................................9
Lighting & Operating instructions label ........................................................10
Operation: Set point adjustment .................................................................11
Fahrenheit versus Celsius ...........................................................................11
Sequence of operation ...............................................................................11
Failure to Light .............................................................................................12
Loss of flame – recycle ................................................................................12
Adaptive learning routine .............................................................................13
Keypad inputs ..............................................................................................13
Automatic reset time ....................................................................................13
Periodic inspection: .....................................................................................13
Winterization: ...............................................................................................14
Damage by Freezing ...................................................................................14
Spring start-up: ............................................................................................15
Error codes .............................................................................................15-16
Contents
Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
�
Basicsafetyprecautionsshouldalwaysbefollowed,includingthefollowing:Failuretofollowinstructionscancausesevereinjuryand/ordeath.
Thisisthesafety-alertsymbol.Whenyouseethissymbolonyourequipmentorinthismanual,lookforoneofthefollowingsignalwordsandbealerttothepotentialforpersonalinjury.
WARNINGwarnsabouthazardsthatcouldcauseseriouspersonalinjury,deathormajorpropertydam-ageandifignoredpresentsapotentialhazard.
CAUTIONwarnsabouthazardsthatwillorcancauseminorormoderatepersonalinjuryand/orprop-ertydamageandifignoredpresentsapotentialhazard.Itcanalsomakeconsumersawareofactionsthatareunpredictableandunsafe.
ATTENTIONindicatesspecialinstructionsthatareimportantbutnotrelatedtohazards.
ReAD AnD FoLLoW ALL InstRUCtIons In tHIs oWneR’sMAnUAL AnD on eQUIPMent.
IMPoRtAnt sAFetY InstRUCtIonsBefore installing or servicing this electrical equipment, turn power supply oFF.
KeeP sAFetY LABeLs In GooD ConDItIon AnD RePLACe IF MIssInG oR DAMAGeD.
WARNING–Toreduceriskofinjury,donotpermitchildrentouseorclimbontheheater,pumpsorfilters.Closelysupervisechildrenatalltimes.Componentssuchasthefiltrationsystem,pumps,andheatersmustbepositionedtopreventchildrenfromusingthemasameansofaccesstothepool.CAUTION –Thisheaterisintendedforuseonpermanentlyinstalledswimmingpoolsandmayalsobeusedwithspas.DoNOTusewithstorablepools.Apermanentlyinstalledpoolisconstructedinoronthegroundorinabuildingsuchthatitcannotbereadilydisassembledforstorage.Astorablepoolisconstructedsothatitiscapableofbeingreadilydisassembledforstorageandreassembledtoitsoriginalintegrity.
Thoughthisproductisdesignedforoutdooruse,itisstronglyrecommendedtoprotecttheelectricalcomponentsfromtheweather.Selectawelldrainedarea,onethatwillnotfloodwhenitrains.Itrequiresfreecirculationofairforcooling.Donotinstallinadampornon-ventilatedlocation.
WARNING –Itisrequiredthatlicensedelectriciansdoallelectricalwiring.RiskofElectricShock.Hazardousvoltagecanshock,burn,causedeathorseriouspropertydamage.Toreducetheriskofelectricshock,doNOTuseanextensioncordtoconnectunittoelectricsupply.Provideaproperlylocatedoutlet.AllelectricalwiringMUSTbeinconformancewithapplicablelocalandnationalcodesandregulations.Beforework-ingonthisunit,turnoffpowersupplytotheheater.
WARNING –Toreducetheriskofelectricshockreplacedamagedwiringimmediately.Locateconduittopreventabusefromlawnmowers,hedgetrimmersandotherequipment.
WARNING –Failuretobondtopoolstructurewillincreaseriskforelectrocutionandcouldresultininjuryordeath.Toreducetheriskofelectricshock,theelectricianmustcomplywithinstallationin-structionsandmustbondtheheateraccordingly.Inaddition,thelicensedelectricianmustalsoconformtolocalelectricalcodesforbondingrequirements.
sAFetY InFoRMAtIon
Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
�
notes to tHe eLeCtRICIAn:Useasolidcopperconductor,size8orlarger.Runacontinuouswirefromexternalbondinglugtorein-
forcingrodormesh.ConnectaNo.8AWGsolidcopperbondingwiretothegroundinglugprovidedontheheaterandtoallmetalpartsofswimmingpoolorspa,andtoallelectricalequipment,metalpiping(exceptgaspiping),andconduitwithin5ft.(1.5m)ofinsidewallsofswimmingpoolorspa.
IMPORTANT-ReferenceNECcodesforallwiringstandardsincluding,butnotlimitedto,grounding,bondingandothergeneralwiringprocedures.
WARNING – Suction Entrapment Hazard.Suctioninsuctionoutletsand/orsuctionoutletcoverswhicharedamaged,broken,cracked,missing,orunsecuredcancausesevereinjuryand/ordeathduetothefol-lowingentrapmenthazards:
Hair Entrapment-Haircanbecomeentangledinsuctionoutlets.
Limb Entrapment-Alimbinsertedintoanopeningofasuctionoutletorsuctionoutletcoverthatisdamaged,broken,cracked,missing,ornotsecurelyattachedcanresultinamechanicalbindorswellingofthelimb.
Body Suction Entrapment-Adifferentialpressureappliedtoalargeportionofthebodyorlimbscanresultinanentrapment.
Evisceration/ Disembowelment-Avacuumapplieddirectlytotheintestinesthroughanunprotectedsuctionoutletsumporsuctionoutletcoverwhichisdamaged,broken,cracked,missing,orunsecuredcanresultinevisceration(disembowelment).
Mechanical Entrapment-Thereispotentialforjewelry,swimsuit,hairdecorations,finger,toeorknuck-letobecaughtinanopeningofasuctionoutletorsuctionoutletcoverresultinginmechanicalentrap-ment.
WARNING-Toreducetheriskofentrapmenthazards:• Whensuctionoutletsarelessthana18”x23”equivalent,aminimumoftwofunction-ingsuctionoutletsperpumpmustbeinstalled.Suctionoutletsinthesameplane(i.e.floororwall),mustbeinstalledaminimumofthreefeet(3’)[1meter]apart,asmea-suredfromnearpointtonearpoint.
• Dualsuctionoutletsshallbeplacedinsuchlocationsanddistancestoavoid“dualblockage”byauser.
• Dualsuctionfittingsshallnotbelocatedonseatingareasoronthebackrestforsuchseatingareas.
• Themaximumsystemflowrateshallnotexceedtheflowratingofanylisted(percurrentrevisionofASME/ANSIA112.19.8)suctionoutletcoverinstalled.
• NeverusethePoolorSpaifanysuctionoutletcomponentisdamaged,broken,cracked,missing,ornotsecurelyattached.
• Replacedamaged,broken,cracked,missing,ornotsecurelyattachedsuctionoutletcomponentsim-mediately.
• InstalltwoormoresuctionoutletsperpumpinaccordancewithlatestAPSP(formallyNSPI)Stan-dardsandCPSCguidelines.FollowallapplicableNational,State,andLocalcodes.
Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
5
WARNING–Failuretoremovepressuretestplugsand/orplugsusedinwinterizationofthepool/spafromthesuctionoutletscanresultinanincreasepotentialforsuctionentrapmentasdescribedabove.
WARNING–Failuretokeepsuctionoutletcomponentsclearofdebris,suchasleaves,dirt,hair,paperandothermaterialcanresultinanincreasepotentialforsuctionentrapmentasdescribedabove.
WARNING–Suctionoutletcomponentshaveafinitelife,thecover/grateshouldbeinspectedfre-quentlyandreplacedatleasteverytenyearsoriffoundtobedamaged,broken,cracked,missing,ornotsecurelyattached.
WARNING–AllsuctionanddischargevalvesMUSTbeOPENwhenstartingthecirculationsystem.Failuretodosocouldresultinseverepersonalinjuryand/orpropertydamage.AlldrainsandsuctionoutletsMUSThaveproperlyinstalledcovers,securelyattachedusingthescrewssuppliedwiththecov-ers.Ifscrewsarelost,orderreplacementpartsfromyoursupplier.
WARNING – Hazardous Pressure.Poolandspawatercirculationsystemsoperateunderhazardouspressureduringstartup,normaloperation,andafterpumpshutoff.Standclearofcirculationsystemequipmentduringstartup.Failuretofollowsafetyandoperationinstructionscouldresultinviolentseparationofthepumphousingandcoverduetopressureinthesystem,whichcouldcausepropertydamage,severepersonalinjury,ordeath.Beforeservicingpoolandspawatercirculationsystem,allsystemandpumpcontrolsmustbeinoffpositionandfiltermanualairreliefvalvemustbeinopenposition.Beforestartingsystempump,allsystemvalvesmustbesetinapositiontoallowsystemwatertoreturnbacktothepool.Donotchangefiltercontrolvalvepositionwhilesystempumpisrunning.Beforestartingsystempump,fullyopenfiltermanualairreliefvalve.Donotclosefiltermanualairreliefvalveuntilasteadystreamofwater(notairorairandwater)isdischarged.
WARNING – Separation Hazard.Failuretofollowsafetyandoperationinstruc-tionscouldresultinviolentseparationofpumpcomponents.Strainercovermustbeproperlysecuredtopumphousingwithstrainercoverlockring.Beforeservicingpoolandspacirculationsystem,manualairreliefvalvemustbeinopenposition.Donotoperatepoolandspacirculationsystemifasystemcomponentisnotassembledproperly,damaged,ormissing.Donotoperatepoolandspacirculationsystemunlessfilterairreliefvalvebodyisinlockedpositioninfilterupperbody.
WARNING –Neveroperateortestthecirculationsystematmorethan40PSI.
WARNING–Fireandburnhazard.Motorsoperateathightemperaturesandiftheyarenotproperlyisolatedfromanyflammablestructuresorforeigndebristheycancausefires,whichmaycauseseverepersonalinjuryordeath.Itisalsonecessarytoallowthemotortocoolforatleast20minutespriortomaintenancetominimizetheriskofburns.
WARNING–Failuretoinstallaccordingtodefinedinstructionsmayresultinseverepersonalinjuryordeath.
Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
�
WARNING–Thefollowing“SafetyRulesforHotTubs”recommendedbytheU.S.ConsumerProductSafetyCommissionshouldbeobservedwhenusingthespa.
1. Spaorhottubwatertemperaturesshouldneverexceed104°F[40°C].Atemperatureof100°F[38°C]isconsideredsafeforahealthyadult.Specialcautionissuggestedforyoungchildren.Pro-longedimmersioninhotwatercaninducehyperthermia.
2. Drinkingofalcoholicbeveragesbeforeorduringspaorhottubusecancausedrowsiness,whichcouldleadtounconsciousnessandsubsequentlyresultindrowning.
3. Pregnantwomenbeware!Soakinginwaterabove100°F[38°C]cancausefetaldamageduringthefirstthreemonthsofpregnancy(resultinginthebirthofabrain-damagedordeformedchild).Preg-nantwomenshouldadheretothe100°F[38°C]maximumrule.
4. Beforeenteringthespaorhottub,usersshouldcheckthewatertemperaturewithanaccuratether-mometer;spaorhottubthermostatsmayerrinregulatingwatertemperaturesbyasmuchas4°F(2.2°C).
5. Personstakingmedications,whichinducedrowsiness,suchastranquilizers,antihistaminesoranti-coagulants,shouldnotusespasorhottubs.
6. Ifthepool/spaisusedfortherapy,itshouldbedonewiththeadviceofaphysician.Alwaysstirpool/spawaterbeforeenteringthepool/spatomixinanyhotsurfacelayerofwaterthatmightexceedhealthfultemperaturelimitsandcauseinjury.Donottamperwithcontrols,becausescaldingcanresultifsafetycontrolsarenotinproperworkingorder.
7. Personswithamedicalhistoryofheartdisease,circulatoryproblems,diabetesorbloodpressureproblemsshouldobtainaphysiciansadvicebeforeusingspasorhottubs.
8. Hyperthermiaoccurswhentheinternaltemperatureofthebodyreachesalevelseveraldegreesabovenormalbodytemperatureof98.6°F[37°C].ThesymptomsofHyperthermiainclude:drowsi-ness,lethargy,dizziness,fainting,andanincreaseintheinternaltemperatureofthebody.
The effects of Hyperthermia include:1. Unawarenessofimpendingdanger.2. Failuretoperceiveheat.3. Failuretorecognizetheneedtoleavethespa.4. Physicalinabilitytoexitthespa.5. Fetaldamageinpregnantwomen.6. Unconsciousnessresultingindangerofdrowning.
DEFINITIONS:SuctionOutlet– ThetermSuctionOutletisafitting,fittingassembly,cover/grateandrelatedcompo-
nentsthatprovideameansforwatertoexitthepoolandintothepumpcirculatingsystem.
InchesofMercury(inHg)- Aunitformeasuringpressurebelowatmospheric(“suction”or“vacuum”)(1.0inch
Hg=.491PSI)MainDrain– SeeSuctionOutletPSI– Anabbreviationforpoundspersquareinch.
Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
�
IntRoDUCtIon:Thismanualcontainsinstructionsforinstallation,operation,maintenance,troubleshooting,andpartslists
forthesafeuseoftheswimmingpool/spa/hottubheaters.Haywardstronglyrecommendsthattheownerreadthemanualbeforeusingtheswimmingpool/spa/hottubheater.Ifafterreviewingthemanualanyques-tionsremainunanswered,contactthefactoryorlocalrepresentative.
LIMIteD WARRAntY sUMMARY:Wewarrantthepool/spa/hottubheatertobefreefromdefectsinmaterialsandworkmanship,andwe
willwithinoneyearfromdateofinstallationforallusers,fortheoriginalpurchaser,repairor,atouroption,replacewithoutchargeanydefectivepart.Wefurtherwarrantthatiftheheatexchangerorexchangerheaders(water-containingsection)leakwithinoneyearfromdateofsuchinstallationforallusers,duetodefectsinmaterialsandworkmanship,wewillprovideareplacementpart.Costoffreight,installation,fuel,andservicelabor(afteroneyear)isatuser’sexpense.Forfulldetailsofwarrantyagreement,seewarrantycertificateincludedinthismanual.
ATTENTION:Ifthepool/spa/hottubheaterisdamagedordestroyedbyimpropermaintenance,exces-sivewaterhardness,incorrectwaterchemistry,orfreezingitisnotcoveredunderthemanufacturer’swarranty.
seCtIon I. GeneRAL InFoRMAtIon
Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
8 seCtIon II. ConsUMeR oPeRAtIon & MAIntenAnCe
FoR YoUR sAFetY – ReAD BeFoRe oPeRAtInG tHe HeAteR
GENERAL:Watermustbeflowingthroughtheheaterduringoperation.Checkthatthepumpisoperatingandthesys-
temisfilledwithwaterandpurgedofallairpriortostartingtheheater.Inanewpoolitisrecommendedthatthefilterbeoperatedlongenoughtocompletelycleanandclearthepoolwaterandfiltersystem.
Balancethepool/spawaterchemistryandcleanthefilter.Thenfollowtheinstructionsbelow.
POOL/SPA WATER CHEMISTRY:SeeFigure1.Themineralcontentofswimmingpoolwaterincreasesdailyduetoadditionofpoolsanitiz-
ingchemicalsandnaturalevaporation.Excessmineralswilldepositonpoolwalls,inthefiltrationsystem,andintheheatexchangertubesifthemineralcontentistoohigh.
Changingspawaterregularlyandmaintainingcorrectchemicalbalanceinpool/spawillkeepthepool/spasafeandsanitary,andwillprotecttheheateranditswarrantycoverage.PurchaseaPHwatertestkitandcheckthefollowingchemicallevelsfrequently.
CHLORINE OR BROMINE:Recommendedlevelis1to4ppm.Testbeforeuse.pH:Recommendedideallevel7.4to7.6.HIGHreadingsreducesanitizerefficiency.LOWreadingsarecorrosive.
TOTAL ALKALINITY:80–120ppm.Testweeklyduringregularuse.LOWreadingsarecorrosiveandcauserapidpHchangeswhenchemicalsareadded.
CALCIUM HARDNESS:200–400ppm.Testwheneverpool/spaisfilled.
LOWlevelsofhardnesscanbeverycorrosive.Remember,additionofanychemicalscanchangethelevelsofchlorine,pH,andtotalalkalinity.Itisrecommendedthatresidentialspawaterbechangedevery2to3monthstopreventwaterproblems.
Publicspasmayneedtohavethewaterchangedeveryweek,orevendaily,dependingonthebatherload.
Figure1
Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
9
WARNING:Ifyousmellgasintheapplianceareaornearthefloor(PROPANEISHEAVIERTHANAIRANDHENCESETTLESONTHEFLOOR),stopandfollowtheinstructionsonthefrontcoverofthismanual.Sincepropanecanaccumulateincon-finedareas,extracareshouldbetakenwhenlightingpropaneheaters.
ATTENTION:Donotusetheheaterbelow40°F(4°C)temperaturewithoutadequatetemperaturepro-tection.
WARNING:Donotingestalcoholordrugsduringuseorpriortousingpool,spa,orhottub.Ingestionofsuchintoxicantscancausedrowsiness,whichcanleadtounconsciousness,andsubsequentlyresultindrowning.
USING CHLORINATORS AND CHEMICAL FEEDERS:Followtheinstructionsprovidedwithanyautomaticormanualchlorinatorandchemicalfeeder.All
chemicalsmustbeintroducedanddilutedintothepoolorspawaterbeforebeingcirculatedthroughtheheater.Donotplacechlorinetabletsorbrominesticksdirectlyintotheskimmer.Highchemicalconcentra-tionsmayresultwhenthepumpisnotrunning.Highchemicalconcentrationswillcauseveryrapidcorrosionoftheheatexchanger.ThisdamagewillnotbecoveredbytheHaywardwarranty.
HEATER OPERATION:Fulllightingandshutdowninstructionsareincludedonthelighting&operatinginstructionslabelaffixed
totheinsideofthefrontaccesspanel.SeeFigure2forthelocationofthislabelandthekeypad.SeeFigure3forthelabel.
Lighting&shutdownlabelislocatedontheinsideofthefront accesspanel
Removethese(4)screwstoremovethefrontaccesspane
Keypad
Figure2:Keypadandlabellocations
Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
10
Figure3:Lighting&OperatingInstructionslabel
Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
11
KEYPAD INPUTSThecontrolacceptsuserinputsviathekeypadonthefrontpanel.1. Whenchangingthemodefrom“STANDBY”toeither“SPA”or“POOL”theremaybeuptoa10-
seconddelayfortheblowerfantobeginrunning.Thecontrolperformsaninternalself-testandthenverifiesthattheblowervacuumswitchcontactsareopenbeforeenergizingtheblower.
2. Itisnormalfortheheatertodisplaya1-to2-seconddelayinrespondingtoanykeypadinput.3. Itisnormalfortheheatertodisplayuptoa5-seconddelaywhenthekeypadisusedtoresetthecon-
troltoclearanerrorcode.4. Thecontrolwillacceptamodechangeduringlockoutafter5seconds.Thecontrolwillcontinueto
displaytheerrorcodeandremaininlockoutuntilitisreset.Atresetthecontrolwillgotothelastsavedmode.
OPERATION: SET POINT ADjUSTMENT:Thesetpointtemperatureisdisplayedbypressingthe“UP”or“DOWN”buttonswhilein“POOL”or
“SPA”mode.Thesetpointwillblinkwhileitisdisplayed.Furtherpressingofthe“UP”or“DOWN”buttonswilladjustthesetpointtemperatureupordownasdesired.Thesetpointrangeisbetween65°F(18°C)and104°F(40°C).
FAHRENHEIT vERSUS CELSIUS:ThetemperaturecanbedisplayedinFahrenheitorCelsius.TOchangethedisplay,usethe“MODE”but-
tontoplacetheheaterin“STANDBY”.Thenpressandholdthe“UP”and“DOWN”buttonsuntilthedisplayshowsthe°F/°Cselection.Pressthe“DOWN”buttontotogglebetweenselections.Toaccepttheselection,pressthe“MODE”button.Iftheuserdoesnotact,theselectionwillbeautomaticallyacceptedafter60sec-onds.
WINTERIzATION:Inmoderateclimates,theheatercancontinuetooperateduringshort-termcoldspells.Donotusethe
heatertomaintainthewatertemperaturejustabovefreezingorforfreezeprotection.Caremustbetakentoavoidfreeze-upintheheater.Whenitisusedduringfreezingweather,thepumpmustruncontinuously.Theheaterisnotwarrantedagainstfreeze-ups.Inregionswherefreezingtemperaturesareencountered,allwatermustbedrainedfromtheheaterwhenitisoutofservice,topreventdamagetotheheaterandpiping.Drain-ingtheheatexchangerisrecommendedaspartoftheseason’sshutdownprocedures.
Figure4:Keypad KeypadImput
12
SPRING START-UP – CONSULT A PROFESSIONAL:1. Inspectandcleantheheater,beingsuretheheaterisfreeofleavesanddebrispriortostartup.2. Besureinletandoutletpipingareproperlyattachedtotheheaterandthedrainvalveisclosed.3. Turnthefiltrationsystempump“ON”andallowthesystemtorunlongenoughtopurgealltheair
fromthelines.4. Turnthegassupplytotheheater“ON”.5. Setthetemperaturecontrolusingthekeypadto“POOL”or“SPA”andadjustthesetpointtothe
desiredtemperaturesetting.6. Ifoperatingdifficultiesareencountered,contactaqualifiedservicecompanyforassistance.
ERROR CODES: Figure5liststheerrorcodesthatmaybedisplayedontheheaterdisplayboard. Contactaqualifiedservicecompanyforassistance.
Code Description Information
bDInternalfault/power-uperror
Oninitialtrialforignition.Automaticresetisimmediateoncethegasvalverelaycheckresultsareacceptable.
bDGasvalvesensedas“ON”error
Ifvalveisopenwhenitshouldbeclosedtheheaterwillshutdownandgointolockout.Blowerwilloperateuntilerrorconditioniscorrected.Automaticrestart2minutesaftererroriscorrected.
bDGasvalvesensedas“OFF”error
Ifvalveisclosedbutflameissensedtheblowerwillrunfor5sthenstartanewignitionsequence.Iferroroccurs10timesduringacallforheatthecontrolwillgointolockout.Automaticresetis60minutes.
bD Dataretrievalerror Ifcontrolinputdataiscorruptedtheheaterwillshutdownandgointolockout.
HFFlamepresentwithgasvalve“OFF”error
Ifflameissensedwiththegasvalveoffthecontrolwillgointolockout.Theblowerwillrununtilerrorconditioniscorrected.Whencorrected,controlwillrunblowerfor5sthenautomaticallyrestartafter2minutes.
PFElectricalsupplywiringerror
Thiscodewilldisplayif120Vpolarityisreversed,lowvoltageisdetected,orifthegroundpathisnotsufficient.Resetisimmediateaftererroriscorrected.
AOProverswitchopenerror
Iftheblowerproverswitchdoesnotcloseaftertheblowerstartsthecontrolwillstoptheignitiontrialgointolockout.Theblowerwillcontinuetorun.Automat-icresetisimmediateaftertheswitchcloses.
AO
Proverswitchopenwhenexpectedclosederror
Iftheblowerproverswitchopensunexpectedlyduringoperationthecontrolwillshutdownandattempttore-light.Iftheswitchdoesnotcloseaftertheblowerstartsthecontrolwillgointolockoutwiththeblowerrunning.Automaticresetisimmediateaftererroriscorrected.
Figure5:ERROR CODES
Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
13
AOProverswitchopendur-ingpost-purgeerror
Iftheblowerproverswitchopensduringthepost-purgecycle(heaterisnotfir-ing)thecontrolwilldisplaytheerrorcode.Thepost-purgecyclewillbecom-pletedoncetheblowerproverswitchcloses.
ACProverswitchclosedwhenexpectedopenerror
Iftheblowerproverswitchisclosedbeforeblowerstart-upthecontrolwillnotstarttheblower.Automaticresetisimmediatewhentheswitchopens.
IOIgniteropenerror Ifthecontrolisnotinlockoutandsensesthattheignitercircuitisopenwhen
theblowerisrunningthecontrolwillturnofftheblowerandgointolockout.Automaticrestart2min.aftererroriscorrected.
SF
Thermistorerror Anexcessivetemperaturedifferencebetweenthetwothermistors(5°Formore)oran“outofbounds”conditiononbothsensors(lessthan10°Forgreaterthan180°F)willresultintheerrorcode.Automaticrestartis2minutesaftertheerroriscorrected.
HSExcessivewatertemperatureerror
Ifwatertemperatureexceeds105°Ftheheaterwillshutdownandgointolock-out.Automaticrestartis2minutesafterwatertemp.dropsbelow105°F.
HERapidwatertemperaturerise
Ifwatertemperaturerisestoorapidlytheheaterwillshutdownandgointolock-out.Automaticrestartisafter2minutes.Afterthethirdoccurrenceinthesamecallforheattheheaterwilllockout.
SbKeypadbuttonstuckclosederror
Ifoneofthekeypadbuttonsisclosed(orpressed)formorethan30stheerrorcodewillbedisplayedbutthecontrolwillcontinuetofunction.Theerrorcodewillbeclearedwhentheconditioniscorrected.
IFIgnitionfailureerror Ifthecontrolexceedsthemaximumnumberofignitionretriesorrecyclesthe
heaterwillshutdownandgointolockout.Automaticresetis60minutes.
CE
Communicationerror Ifcommunicationbetweentheignitionboardandthedisplayboardisnotestab-lishedwithin3sofpower-upanerrorwillbedisplayed.Aftercommunicationisestablished,ifitislostfor30s,theerrorwillbedisplayed.Theerrorcodewillbecleareduponavaliddataexchangebetweenboards.
LOLimitstringopenerror Ifthelimitstringopenstheheatershutsdownandgoesintolockout.Automatic
restartis2minutesaftertheerrorconditioniscorrectedandthelimitstringcloses.
EE EEPROMerror Anerrorwasdetectedintheignitioncontrolcircuitboard.
Figure5:ERROR CODES(continued)
Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
14 HAYWARD PooL HeAteR CeRtIFICAte oF LIMIteD WARRAntY
Limitedheaterwarranty:TERMSANDCOVERAGE:Wewarrantourpoolheatertobefreefromdefectsinworkmanshipandmateri-alsundernormaluseandservice.PursuanttothiswarrantyandsubjecttotheConditionsandExceptionsindicatedbelow: 1.Wewillreplace(costoffreight,installation,costoffuel,andservicelaboratuser’sexpense)with
theprevailingcomparablemodel,or,atouroption,repairanypool/spaheaterthatleaksundernor-maluseandservicewithinoneyearfromthedateoforiginalinstallationforallusers.
2.Inaddition,wewillreplace(costoffreight,installation,costoffuel,andservicelaboratuser’sexpense)or,atouroption,repairanypartorpartsofthepool/spaheaterwhichmalfunctionsundernormaluseandservicewithinoneyearfromthedateoforiginalinstallationforallusers.
LIMITATION ON IMPLIED WARRANTIES:WEARENOTLIABLEFORANYCONSEQUENTIALDAMAGESFORBREACHOFANYWRITTENORIMPLIEDWARRANTYOFTHISPRODUCT.Im-pliedwarranties,includingtheWARRANTYofMERCHANTABILITYandallotherimpliedwarrantiesthatmayarisefromcourseofdealingorusageoftradeimposedonthesaleofthisheaterunderlawsofthestatearelimitedindurationtothetermofone(1)yearforallusers.Therearenowarrantieswhichextendbeyondthedescriptiononthefacehereof.Weshallnotinanyeventbeheldliableforanyspecial,indirect,orconse-quentialdamages.
eXPense oF DeLIVeRY AnD InstALLAtIon:Eachpoolheaterorreplacementparttobefurnishedunderthiswarrantyshallbefurnishedatournearest
distributioncenter.Weshallnotpay,norberesponsibleforshippingordeliverychargestotheplaceofinstal-lation,norforlaborchargesorothercostsofremovalorinstallation.Everydefectiveheaterorpartreplacedunderthiswarrantyshallbecomeourproperty,andassuch,mustbereturnedtoourdistributioncenterwithtransportationchargespaidbytheuser.Anyreplacementpoolheaterfurnishedunderthiswarrantyshallre-maininwarrantyonlyfortheunexpiredportionofthiswarranty.
ConDItIons AnD eXCePtIons:Thiswarrantyappliesonlytothepool/spaatitsoriginalplaceofinstallationandonlyfortheoriginal
owner.Itdoesnotapplyifthepoolheaterisinstalledinviolationofanyapplicablecodeorordinance,orisnotinstalled,operatedandmaintainedinaccordancewithourinstructions,orismisused,damagedbyac-cident,weather,actofGod,freezing,watervoidand/orexcesspressure,alteredordisconnected.Itdoesnotapplywithrespectto: 1.AheaternotequippedwithCertifiedC.S.A.limitcontrolsorequivalentpressurereliefvalve. 2.Aheateroperatedwithsettingsinexcessof,and/orwithfuelnotconformingtothoseshownonrat-
ingplate; 3.Aheateronwhichtheserialnumbershavebeenaltered,defaced,orremoved. 4.Leaksarisingfromdefectiveinstallation; 5.Productionofnoise,odors,ordiscolored(rusty,etc.)water; 6.Leakagesubstantiallycontributedtobysediment,limeprecipitateand/orhigherthannormaldis-
solvedsolids(pHabove7.8)inthetank,coppertubes,orwaterways; 7.Leakagecausedsubstantiallycontributedtobycorrosiveelementsintheatmosphere(suchasthe
storageofchlorineorotherchemicals); 8.Leakagecausedsubstantiallyorcontributedtobycorrosivepoolwaterinanacidcondition(pH
below7.2); 9.Damagecausedsubstantiallyorcontributedtobyanexternalsourceofenergy; 10.Apool/spaheaterisawatercontainingdevice.Leakageofwaterfromthisdevicecanbeexpected
atsometimeduetomalfunctionorthelimitations
Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
15
oftheservicelifeofvariouscomponents.Donotinstallthisproductwheresuchleakagecancausedamage.MANUFACTURERISNOTRESPONSIBLEORLIABLEFORANYCOSTSINCURREDBYSUCHDAMAGE.
IN NO CASE ARE WE TO BE HELD LIABLE FOR DAMAGETO SURROUNDING AREA OR PROPERTYCAUSED BY LEAKAGE OR MALFUNCTION.
HoW to CLAIM UnDeR tHIs WARRAntY: Theoriginalowner,upondiscoveringthedefect,mustpresenttheattachedcompletedwarrantyclaimcard
withproofofpurchaseeithertothedealerornotifytheCompanyinwritingateitheraddress:
HAYWARD PooL PRoDUCts, InC.620 DIvISIOn St.ELIzAbEth, nJ 07207
oR
HAYWARD PooL PRoDUCts, InC.2875 POMOnA bOULEvArDPOMOnA, CA 91768
Uponreceiptofsuchnotificationweshalldecidewhethertorepairsuchpartsorreplaceanypoolheater,reservingatalltimestherighttoinspectinordertoverifyanyclaimeddefect.Wealsoreservetherighttohaveourrepresentativesmakeanyinspections,repairs,ortofurnishreplacements.ThiswarrantyisintendedasalegallybindingobligationoftheCompany,enforceableinthecourts.Thiswarrantymaygiveyouspe-cificlegalrightswhichmayvaryfromstatetostate.
LIMItAtIon on LIABILItY: Allintendedrepresentationshavebeenexpresslysetforthinthisdocument.Thiswarrantymaynotbe
extendedbyoraloranyotheradditionalrepresentations,writtensalesinformation,drawings,orothermal-function,isstrictlylimitedtorepairorreplacementofthedefectiveheaterorpart,asprovidedhereinandtheCompanyisnotresponsiblehereunderforincidentalorconsequentialorincidentalcostsordamages.Thecompanyneitherassumes,norauthorizesanypersonorfirmtoassumeforus,anyfurtherliabilityorobligationinconnectionwiththesale,installation,use,maintenance,orexistenceoftheheater.SAFETYWARNING:Poolheatersareheatproducingappliancesandtoavoiddamageorinjuryintheeventofpos-sibleoverheatingoftheouterjacket(1)nomaterialsshouldbestoredagainstthejacketand(2)careshouldbetakentoavoidunnecessarycontact(especiallybychildren)withthejacket.Whenlightingagasheater,thelightinginstructionsmustbefollowedexactlytoprevent“flashback”ofexcessgasintheheater.Electronicignitionheatersandelectricheatersmusthavethepowershutoffwhenmakingadjustmentsto,servicing,orcomingintocontactwiththeheater.UNDERNOCIRCUMSTANCESSHOULDFLAMMABLEMATERI-ALS,SUCHASGASOLINEORPAINTTHINNERS,BEUSEDORSTOREDINTHEVICINITYOFTHEHEATERORINANYLOCATIONFROMWHICHFUMESCOULDREACHTHEHEATER.Foryourcomfort,enjoymentandsafety,pleasereadtheenclosedoperatinginstructionscarefully.
Hayward Pool Products, Inc.620 Division St.Elizabeth, nJ 07207
Hayward Pool Products, Inc.2875 Pomona boulevardPomona, CA 91768
Hayward Pool Products, Inc.2880 Plymouth DriveOakville, Ontario L6h 5r4
Hayward S.A.zoming de Jumetb6040 Jumet, belgique