Fujifilm - Thermoscale film

Post on 24-May-2015

195 views 1 download

Tags:

description

A revolutionary new film that enables anyone to measure heat distribution easily by observing the variation in density and hue.

Transcript of Fujifilm - Thermoscale film

1

Heat distribution measurement film

THERMOSCALE 200C

Mr. Bernard GenoudSales CCTV & Industrial Products

FUJIFILM (Switzerland) AG

2

To measure heat distribution easily by observingthe variation in density and hue.

Contact for5 seconds

Cyan → Change density → Plus Magenta →& Change hue

150 160 170 180 190 200 210 ℃

Contact for20 seconds

What is Thermoscale200C?

℃Properties℃

*Above chart is a sample based on the results of a tests performed at Fujifilm.Before using THERMOSCALE, create a similar chart that is based on the actual measurement conditions.

3

℃Structure℃ ℃Specifications℃

0.09mmThickness

5 sheetsSheets

270mm x 200mmSize

150� - 210�(Contact time = 5-20 sec)

Temperature range*

*Actual temperature range depends on conditions of use includingcontact time, Materials, pressure, and air flow.

0.09mmThickness

270mm x 5mSize

150� - 210�(Contact time = 5-20 sec)

Temperature range*

℃Sheet type℃

℃Roll type℃(Coming soon)

4Heat

℃Color-forming materialdissolves

℃Wall of microcapsule becomes permeable.Color-developing material penetrates the capsule

℃Reacting color-forming material,causing an area of color to appear

℃Principle℃

Color-developingmaterial

Microcapsule

Color-formingmaterial

5

Heat Point

Heat Distribution

Contact

heat

Open

heat

℃Positioning℃

Thermocouple

Thermo label

ThermoscaleThermograph

y

6

Problems about ordinary measurement of heat distribution

℃℃To measure heat distribution

℃℃To measure heat value

℃℃Low resolution

7

Problem 1-1To measure heat distribution

Thermocouples

- Several thermocouplesand Power source required

- Need times to preparespecial jig to set upthermocouples

- Contact condition ischanged by thickness ofattached thermocouples

Powersource

8

If use Thermoscale-Easy operationNo power source requiredCut and fit any dimensions

-Time savingNo special jig required

-Similar to contact conditionFlat and thin film

Thermoscale

9

Thermography -Just measure the surfaceof target but not measure thereal heat distribution

℃℃℃℃

Problem 1-2To measure heat distribution

10℃℃℃℃

-RealityMeasure the real heatdistribution of target

Thermoscale

If use Thermoscale

11℃℃℃℃

Point A℃Center℃Point B

℃Corner℃

Time

Temperature

AB

Same ultimate temperatureBut different heat value

Problem 2To measure heat value

12℃℃℃℃

Thermoscale Point A℃Center℃Point B

℃Corner℃

If use Thermoscale

Time

Temperature

AB

-Process controlVisualize heat value

Heat value (A-B)

13℃℃℃℃

Temperature

Heat

Problem 3Low resolution

10µm

Electronic wiring

Heat will be changed according tothe condition of contacted “Work”

Work

-Not measure 10µ℃ widthby thermocouples

-Not measure several tens ofpoints all at once

14℃℃℃℃

℃℃

Thermoscale

-High resolutionVisualize several 10µm

If use Thermoscale

-High performanceMeasure several tens ofpoints all at once

10µm

- Design electronic wiring pattern- Control heat unevenness

Work

15

Application Examples

16

Expected application

Validation of sterilizationCheck the heat sealer for packaging of sealable pouches

NG OK

Thermoscale200C

17

Conclusion

Thermoscale has the following advantages:

• Can be used in a wide range of applications• Gives accurate results• Covers a wide temperature range with different film types• Is simple to handle

The use of Thermoscale Film can accelerate the developmentof products in R&D and increases the productivity.

18

Thank you very much for your attention!

Distributor for Switzerland:FUJIFILM (Switzerland) AGNiederhaslistrasse 128157 DielsdorfTel.: +41 (0) 44 855 50 50industrial@fujifilm.chwww.fujifilm.ch/industrial