THE HIGH PERFORMANCE INSULATIONFOR INDUSTRIAL PROCESSES
• Built in water vapor barrier reduces risk of corrosionunder insulation (CUI)
• Highest system reliability
• IMO Certified• Lloyds and Bureau Veritas approved
Technical Data - AF/Armaflex
Brief description Highly-flexible, closed-cell insulation material with high water vapour diffusion resistance and low thermal conductivity.Material type Elastomeric foam based on synthetic rubber. Factory made flexible elastomeric foam (FEF) according to EN 14304.Colour BlackApplications Thermal insulation / protection of pipes, vessels and ducts (incl. elbows, fittings, flanges etc.) in industrial and process equipment facilities.Special Features Increasing insulation wall thicknesses for tubes ensures that the surface temperature is maintained as the pipe diameter is increased.Assembly The Armaflex Installation manual should be consulted before assembly. Please consult our Customer Service Centre.Remarks EC Certificate of Conformity no. 0543 of Güteschutzgemeinschaft Hartschaum e.V. , Celle
Property Value/Assessment Test*1 Super-vision*2
Special Remark
Temperature RangeTemperature Range max. service temperature + 110 °C (+ 85 °C if sheet is glued to the
object with its whole surface.)○ Tested acc. to
EN 14706,EN 14707 andEN 14304min. service temperature1 -50 °C
Thermal ConductivityThermalConductivity
ϑm +/-0 °C λ= ○/● Declared acc. toEN ISO 13787Tested acc. toEN 12667EN ISO 8497
Tubes(AF-1 toAF-4)
λ ≤ 0.033. W/(m · K) [33 + 0,1· ϑm + 0,0008 · ϑm²]/1000
Tubes(AF-5 toAF-6)
λ ≤ 0.036. W/(m · K) [36 + 0,1· ϑm + 0,0008 · ϑm²]/1000
Sheets(AF-13MMtoAF-32MM)
λ ≤ 0.033. W/(m · K) [33 + 0,1· ϑm + 0,0008 · ϑm²]/1000
Sheets(AF-50MM)
λ ≤ 0.036. W/(m · K) [36 + 0,1· ϑm + 0,0008 · ϑm²]/1000
Water vapour diffusion resistanceWater vapourdiffusion resistance
Sheets (AF-13MM toAF-32MM)
μ ≥ 10,000 ○/● Tested acc. toEN 12086and EN 13469Sheets (AF-50MM) and
Tubes (AF-5 to AF-6)μ ≥ 7,000
Fire performanceReaction to fire2 tubes BL-s3, d0 ○/● Classified acc. to
EN 13501-1Tested acc. toEN 13823EN ISO 11925-2sheets B-s3,d0
Other Fire Class IMO FTP Code, Annex 1 Part 2 & Part 5 ○/● IMO Approved byLloyds and BureauVeritasUL & FM - approved
Acoustic PerformanceReduction ofstructure-bornesound transmission
Insulation effect ≤ 28 dB(A) Tested acc. toEN ISO 3822-1
Weighted soundabsorptioncoefficient αw
≤ 0.45 Tested acc. toEN ISO 354
Other technical featuresDimensions andtolerances
In accordance with EN 14304, table 1 Tested acc. toEN 822,EN 823, EN 13467
Acoustic InsertionLoss
When used as part of a system AF/Armaflex complies to ISO 15665 Classes A to C and Shell DEP31.46.00.31-Gen Class D.
Tested according toISO 3741
1. For temperatures below -50 °C please contact our Customer Service Center to request for the corresponding technical information.
2. The reaction to fire classification is valid on metal or solid, mineral surfaces.
*1 Further documents such as test certificates, approvals and the like can be requested using the registration number given.
*2 ●: Official supervision by independent institutes and /or test authorities ○: Own in-factory quality monitoring
All data and technical information are based on results achieved under typical application conditions. Recipients of this information should, in their own interest and responsibility, clarify with us in due time whether or not the data and informationapply to the intended application area. Installation instructions are available in our Armaflex installation manual. Please consult our Customer Service Center before insulating stainless steels. For outside use, Armaflex should be protected with asuitable outer covering within 3 days of installation. For some refrigerants the discharge temperature may exceed +110 °C, please consult our Customer Service Center for further information.
notes