Post on 28-Jan-2016
description
A Series
EVAK PUMP TECHNOLOGY CORP.
A - Series
Evak Pump Technology Corp.No. 551, Zhongshan Rd., Qingshui Dist.,Taichung City 436, Taiwan.Tel : +886-426-233556Fax: +886-426-235559www.evak-pumps.com
Vertical Multistage Centrifugal in-line Pumps
50 Hz
AVC/AVI/AVS
Vol. PIAV-14011
ISO-9001
Type Key
A-Series
02EVAK PUMP TECHNOLOGY CORP.
AVC/AVI/AVS-Series
Index Vertical Multistage Centrifugal Pump
Pumps & Pumps
C IS
A-series Number of Stages (Impeller)02: 2 stages03: 3 stages04: 4 stages05: 5 stages06: 6 stages ...etc
Delivery (m³ /h)1M : 1 m³ /h3M : 3 m³ /h5M : 5 m³ /h10M : 10 m³ /h15M : 15 m³ /h20M : 20 m³ /h32M : 32 m³ /h45M : 45 m³ /h64M : 64 m³ /h90M : 90 m³ /h120M : 120 m³ /h150M : 150 m³ /h
Pump Type
Pump material
V : Vertical
Cast iron(Discharge & Suction) Stainless steel 304Stainless steel 316
: ::
AVC- 3M02
Index / Type Key---------------------------AVC/I/S General data------------------ConstructionAVC/I/S 1M/3M/5M/10M/15M/20M--AVC/I/S 32M/45M/64M/90M----AVC/I/S 120M/150M-------------------Pump Curve & DimensionsAVC/I/S 1 M ----------------------------------AVC/I/S 3 M ----------------------------------AVC/I/S 5 M ----------------------------------AVC/I/S 10 M --------------------------------
AVC/I/S 15 M ----------------AVC/I/S 20 M ----------------AVC/I/S 32 M ----------------AVC/I/S 45 M -----------------AVC/I/S 64 M -----------------AVC/I/S 90 M -----------------AVC/I/S 120 M ---------------AVC/I/S 150 M ---------------Install Mechanical Seals-Troubleshooting-------------Nameplate-----------------------
23
26
29
32
35
38
41
44
47
48
49
02
03
08
09
10
11
14
17
20
The AVC, AVI and AVS pumps are non-self priming vertical multistage pump of in-line design, flange or with Victaulic coupling with equally sized suction and discharge ports. Stage construction with stainless steel impellers, chambers and pressure casing. Pump stub shaft and motor shaft of the IEC-standards motor are directly close coupled. All pumps are equipped with a cartridge type mechanical seal for easy maintenance.
www.evak-pumps.com 04
A-Series 50HZ Vertical Multistage Centrifugal in-line PumpsAVC / AVI / AVS
AVC AVI
EVAK PUMP TECHNOLOGY CORP.
AVS
AVC/AVI/AVS 50 Hz
1M
3M
5M
10M
15M
20M
32M
45M
64M
90M
120M
150M
Stages
02-36
02-36
02-36
01-1617-2201-1012-1701-1012-17
(01-1)-7(08-2)-14
(01-1)-5(06-2)-11
(12-2)-(13-2)(01-1)-5
(06-2)-(08-1)
(01-1)-4(05-2)-6
01-7
(01-1)-6
Maximum Operating Pressures
25bar
25bar
25bar
16bar25bar16bar25bar16bar25bar16bar30bar
16bar30bar33bar16bar30bar
16bar30bar
30bar
30bar
Stages
02-36
02-2931-3602-1618-3601-6
07-2201-3
04-1701-3
04-17(01-1)-4
(05-2)-10(11-2)-14(01-1)-2(03-2)-5
(06-2)-(13-2)(01-1)-(02-2)(02-1)-(04-2)(04-1)-(08-1)
(01-1)-1(02-1)-(03-2)
03-601-(02-1)02-(05-1)(06-1)-7(01-1)-1
(02-1)-(04-2)(05-2)-6
Maximum Inlet Pressures
10bar
10bar15bar10bar15bar8bar
10bar8bar
10bar8bar
10bar4bar
10bar15bar4bar
10bar15bar4bar
10bar15bar4bar
10bar15bar10bar15bar20bar10bar15bar20bar
Standard Cartridge type mechanical seal made of Silicon Carbide/ Silicon Carbide/EPDM or Viton. Based on the type of application, alternative materials are available for the seal and the elastomers. The cartridge type mechanical seal can be replaced in minutes without special tools and without dismantling the pump.
Mechanical Seals
Rule to follow: The inlet pressure + the pressure against a closed valve < Max. Operating pressure.All technical information is subject to change without notice.
Product Data
Maximum operating and inlet pressures
>Flange standards : Refer to dimensional drawings
Featurein-line design /High Efficiency Reliability/Easy Maintenance/Wide Range
ApplicationIrrigation and agricultureWater supply / Light industryPressure boosting / Water treatmentHeating, ventilation / air-conditioning
AVC / AVI /AVS
Nominal flow (m³/h)Flow range (m³/h)Max. pressure (bar)Fluid temperature (˚C)Motor power (kw) MotorMains connection 1 phase ( V/Hz )Mains connection 3 phase ( V/Hz )Insulation classEnclosure classAmbient temperatureAVC Pipe ConnectionFlange
AVI/S Pipe ConnectionFlange
Victaulic-connections
Mechanical SealsSeals
Range50Hz
220-240 V 50Hz
0.37-7.5 kw 220-240/380-415 V 50Hz From 11kw 380-415 V 50 Hz
F
IP 55
Max. +50 ˚C
-15~+120
SIC/SIC
EPDM:Standard
Viton:Optional
EPDM:0.37kW-45kW
Viton:55kW-75kW
1
0.7-2.4
21.5
0.37-2.2
DN 25/
DN 32
DN 25/
DN32
R 1 1/4
DN32
3
1.2-4.5
23
0.37-3
DN 25/
DN 32
DN 25/
DN32
R 1 1/4
DN32
5
2.5-8.5
24
0.37-5.5
DN 25/
DN 32
DN 25/
DN32
R 1 1/4
DN32
10
5-13
21.5
0.37-7.5
DN 40
DN 40
R 2
DN50
15
8.5-23.5
23
1.1-15
DN 50
DN 50
R 2
DN50
20
10.5-29
24.3
1.1-18.5
DN 50
DN 50
R 2
DN50
32
15-40
27.5
1.5-30
DN 65
DN 65
N/A
45
22-58
33
3-45
DN 80
DN 80
N/A
64
30-85
21.8
4-45
DN 100
DN 100
N/A
90
45-120
20
5.5-45
DN 100
DN 100
N/A
120
60-160
20.4
11-75
DN 125
DN 125
N/A
150
75-180
18.7
11-75
DN 125
DN 125
N/A
1 3 5 10 15 20 32 45 64 90 120 150
Type of Seal
Seal TypeMechanical SealsS:Cartridge seal
QQUUQBUB
SealsEV
••
OptionalOptionalOptional
AVC AVI AVS
••
OptionalOptionalOptional
•Optional
••
OptionalOptionalOptional
•Optional
•Optional
List of Materials
Q:U:B:
Silicon carbideTungsten carbide
Carbon
EPDMViton
E:V:
www.evak-pumps.com 06All technical information is subject to change without notice.
•Squirrel cage in short circuit, aluminum casing up to 22 kw, totally enclosed, fan-cooled, 2-pole standard motor. •Standard supply Evak motors up to 1.1 kw. Other motor brands for higher powers.•Electrical data Enclosure class: IP 55 Insulation class: F Standard voltages: P2: 0.37-7.5 kw 3x220-240/380-415 V P2: From 11kw 3x380-415 V•The motors have efficiency values that fall within the range normally referred to as high efficiency. •Ambient temperature: Max. +50˚C
AVC / AVI / AVS Performance Range
Q (M³/H)
Q (L/M)
50Hz2850rpm
H[m]
400
300
200
100
80
60
40
30
20
10
0.7 1 2 3 4 5 6 8 10 20 30 40 50 60 80 100 200
11 16 33 50 66 83 100 133 166 333 500 666 833 1000 1333 1666 3332
1M 5M 15M 32M 64M 120M
3M 10M 20M 45M 90M 150M
Motor Data
AVC,AVI,AVS-Series 50HZ Vertical Multistage CentrifugalIn-line Pumps
EVAK PUMP TECHNOLOGY CORP.
AVC,AVI,AVS-Series 50HZ Vertical Multistage CentrifugalIn-line Pumps
RecommendedPumped fluid “Fluid Concentration, temperature” EPDMEPDM VitonViton
AVC(I) AVS
Acetic acid anhydride
Alkaline cleaner
Aluminium sulphate
Ammonia water (A. hydroxide)
Ammonia hydrogen carbonate
Benzoic acid
Boric acid
Butanol
Calcium acetate
Calcium hydroxide
Chromic acid
Condensate
Copper sulphate
Deionic (fully desalinated water)
Ethanol
Ehylene glycol/Diethylene glycol
Fixer
Formic acid
25°C
10%,25°C
20%,40°C
10%,40°C
10%,90°C
Unsaturated solution,60°C
60°C
30%,50°C
Saturated solution,50°C
1%,20°C
90°C
Unsaturated solution,60°C
50°C
100%,20°C
40%,70°C
25°C
5%,20°C
Pumped Liquids
AVC/I/S pumps can handle a wide variety of liquids, each with its own characteristic.
AVC/INon-corrosive liquidsFor fluid transfer, circulation and pressure boosting of cold or hot clean water.
AVSIndustrial liquidsLight acidsThe fluids covered in the list are not complete. Data on the application limits of different pump materials when handling any of the listed fluids are considered to be the best choices. However, the table is intended as a general guide only, and cannot replace actual esting of the pumped fluids and pump materials under specific working conditions.When choosing the pump version, sufficient attention should be given to the flow medium, such as density, solidification point, viscosity as well as ex-protection requirement. The limits of applicability of the pumps, based on pressure and temperature must also be considered.
3PH-415V 3PH-660V 3PH-690V3PH-220VHP KW Pole Flange Frame 3PH-240VNominal Current in [A]Motor Type
3PH-380V
0.50.751.01.52.03.04.05.57.5101520253040506075
100
0.370.550.751.11.52.23.04.05.57.51115
18.5223037455575
2222222222222222222
B14B14B14B14B14B14B14B14B5B5B5B5B5B5B5B5B5B5B5
71A71B80A80B90S90L
100L112M132S132S160M160M160L180M200L200L225M250M280S
1.82.63.45.16
9.512.114.9
1.92.73.65.26.210
12.515
11.52
2.93.557
8.612.11621
28.434.741.155.768.387.2101134
1.11.62.13
3.65.87.28.712
15.319.226
31.837.751
62.578.692.5123
79.2
6.98.8
www.evak-pumps.com 08
EVAK PUMP TECHNOLOGY CORP.
AVC-1M,3M,5M,10M,15M,20M
57
82
36
59
37
44
4824
1218
AVI/S-1M,3M,5M,10M,15M,20M
62
Construction
RecommendedPumped fluid “Fluid Concentration, temperature” EPDMEPDM VitonViton
AVC(I) AVS
Fruit juiceGlycerineHeating oil (Light)Hydraulic oilIsopropanolLactic acidLinoleic acidLinseed oilLiqueurMaize oilMaleic acidMethanolMotor oilOil-water-mixtureOxalic acidPeanut oilPhosphoric acidPolyglycolsPolyethylene glycolsPotassium carbonatePotassium hydrogen carbonatepotassium permanganatePotassium sulphateRapeseed oilSilicone oilSodium carbonateSodium hydroxideSodium nitrateSodium phosphateSodium sulphateSulphuric acidWaterSwimming pool waterDeionicDistilled waterDecarbonate waterSoft waterHeating waterBoiler waterPure waterRinsing water
50°C50%, 50°C
100%, 100°C
10%, 20°C100%, 20°C
60°C60°C80°C
50%, 50°C100%, 20°C100%, 80°C
100°C1%, 20°C
100%, 80°C20%, 20°C
90°C40%, 70°C10%, 60°C10%, 60°C5%, 20°C
Unsaturaed solution, 80°C100%, 80°C
100%10%, 60°C25%, 50°C
Unsaturated solution, 80°C5%, 100°C10%, 60°C5%, 25°C
35°C50°C50°C
AVI
AVI
36
37
56
18
12
44
57
4882
59
24
AVC,AVI,AVS-Series 50HZ Vertical Multistage CentrifugalIn-line Pumps
AVC,AVI,AVS-Series 50HZ Vertical Multistage CentrifugalIn-line Pumps
All technical information is subject to change without notice.
Construction
365618374882122459
624457
Pos. Name AVC-1,3,5,10,15,20M
Pump head Pump head coverImpellerShaftOuter SleeveO-ring for outer sleeve
ChamberNeck ringBaseBaseBase plateCouplingMechanical seal
Material
Cast IronStainless steel
Stainless steel
Stainless steel
Stainless steel
EPDMStainless steel
PTFECast IronStainless steel
Cast IronFe-Cu-CCartridge type
ASTM 25BN/AAISI 304AISI 431AISI 304
AISI 304
ASTM 25BN/AN/AMPIF FC0525
EN-GJL-200N/A1.43011.40571.4301
1.4301
EN-GJL-200N/AN/ASINT C11
EuropeStandard
USA
AVI-1,3,5,10,15,20M AVS-1,3,5,10,15,20M
EuropeStandard
USAEN-GJS-450-10
1.43011.43011.40571.4301
1.4301
N/A1.4301EN-GJL-200SINT C11
ASTM 65-45-12
AISI 304AISI 304AISI 431AISI 304
AISI 304
N/AAISI 304ASTM 25BMPIF FC0525
EuropeStandard
USAEN-GJS-450-10
1.44011.44011.44011.4401
1.4401
N/A1.4401EN-GJL-200SINT C11
ASTM 65-45-12
AISI 316AISI 316AISI 316AISI 316
AISI 316
N/AAISI 316ASTM 25BMPIF FC0525
www.evak-pumps.com 10
EVAK PUMP TECHNOLOGY CORP. EVAK PUMP TECHNOLOGY CORP.
Construction
53
36
48
14
37
57
18
12
24
82
42
59
36
53
14
62
48
82
12
57
37
18
59
42
24
AVC-120M,150M AVI/S-120M,150M
Construction
AVC-32M,45M,64M,90M AVI/S-32M,45M,64M,90M
A-Series 50HZ Vertical Multistage Centrifugal in-line Pumps
All technical information is subject to change without notice.
AVC,AVI,AVS-Series 50HZ Vertical Multistage CentrifugalIn-line Pumps
AVC,AVI,AVS-Series 50HZ Vertical Multistage CentrifugalIn-line Pumps
Construction
36
5318374882122459
62571442
Pump head
Motor bracketImpellerShaftOuter sleeveO-ring for outer sleeve
ChamberNeck ringBaseBaseBase plateMechanical sealBearing ringBottom bearing ring
Cast ironStainless steelCast ironStainless steelStainless steelStainless steelEPDMStainless steelCarbon Fiber+POB+PTFE
Cast ironStainless steelCast ironCartridge type
Tungsten carbide
EN-GJL-250
EN-GJL-2501.43011.40571.4301
1.4301
EN-GJL-250N/AN/A
AISI 316ASTM 35BAISI 316AISI 316AISI 316
AISI 316
N/AAISI 316
ASTM 35B
1.4401EN-GJL-250
1.44011.44011.4401
1.4401
N/A1.4401
EN-GJL-250
AISI 304ASTM 35BAISI 304AISI 431AISI 304
AISI 304
N/AAISI 304
ASTM 35B
1.4301EN-GJL-250
1.43011.40571.4301
1.4301
N/A1.4301
EN-GJL-250
ASTM 35B
ASTM 35BAISI 304AISI 431AISI 304
AISI 304
ASTM 35BN/AN/A
Pos. Name AVC-32,45,64,90MMaterial
EuropeStandard
USA
AVI-32,45,64,90M AVS-32,45,64,90M
EuropeStandard
USA EuropeStandard
USA
Bronze POB+Graphite+PTFEBronze
Construction
36
53
1718374882122459
6262A5742
Pump head
Motor bracket (15~60HP)
Motor bracket (75~100HP)
BearingImpellerShaftOuter sleeveO-ring for outer sleeve
ChamberNeck ringBaseBaseBase plateBase plateMechanical sealBottom bearing ring
Cast ironStainless steelCast ironCast ironPTEFStainless steelStainless steelStainless steelEPDMStainless steelPTFECast ironStainless steelCast ironCast ironCartridge typeSIC/SIC
EN-GJL-250N/A
EN-GJL-250EN-GJS-450-10
1.43011.40571.4301
1.4301
EN-GJL-250N/AN/A
EN-GJL-450-10
N/AAISI 316
ASTM 35BASTM 65-45-12
AISI 316AISI 316AISI 316
AISI 316
N/AAISI 316
ASTM 65-45-12
ASTM 65-45-12
N/A1.4401
EN-GJL-250EN-GJS-450-10
1.44011.44011.4401
1.4401
N/A1.4401
EN-GJL-450-10
EN-GJL-450-10
N/AAISI 304
ASTM 35BASTM 65-45-12
AISI 304AISI 431AISI 304
AISI 304
N/AAISI 304
ASTM 65-45-12
ASTM 65-45-12
N/A1.4301
EN-GJL-250EN-GJS-450-10
1.43011.40571.4301
1.4301
N/A1.4301
EN-GJL-450-10
EN-GJL-450-10
ASTM 35BN/A
ASTM 35BASTM 65-45-12
AISI 304AISI 431AISI 304
AISI 304
ASTM 35BN/AN/A
ASTM 65-45-12
Pos. Name AVC-120,150MMaterial
EuropeStandard
USA
AVI-120,150M AVS-120,150M
EuropeStandard
USA EuropeStandard
USA
57
12
17
18
42
82
62A
53
36
37
48
24
59
57
12
17
18
42
82
62A
53
36
37
48
24
59
62
www.evak-pumps.com 12
EVAK PUMP TECHNOLOGY CORP.
Dimensions & Weights AVC-1M
H1
G1/2 G1/2
H2
D1
D2
G1/2
Flange(DIN-ANSI-JIS)PN25/DN25/32
All technical information is subject to change without notice.
AVC-1M02AVC-1M03AVC-1M04AVC-1M05AVC-1M06AVC-1M07AVC-1M08AVC-1M09AVC-1M10AVC-1M11AVC-1M12AVC-1M13AVC-1M15AVC-1M17AVC-1M19AVC-1M21AVC-1M23AVC-1M25AVC-1M27AVC-1M30AVC-1M33AVC-1M36
AVC-1MPump Type Motor Dimension (mm)
P2 DINflange
DIN flangeH1 D1H2 D2
Net weight(kg)
kwHP0.50.50.50.50.50.5
0.750.750.750.75
111
1.51.51.51.522233
115115115115115115115115115115115115115115115115115141141141141141
23.423.423.824.224.524.925.826.126.526.929.429.830.532.333.133.834.644.044.845.949.951.0
141141141141141141141141141141141141141141141141141177177177177177
474474492510528546564582600618682700736772808844880988
1024107811321186
279279297315333351369387405423447465501537573609645697733787841895
0.370.370.370.370.370.370.550.550.550.550.750.750.751.11.11.11.11.51.51.52.22.2
AVC,AVI,AVS-Series 50HZ Vertical Multistage CentrifugalIn-line Pumps
AVC,AVI,AVS-Series 50HZ Vertical Multistage CentrifugalIn-line Pumps
Performance Curve
30
0 0.3 0.6 0.9 1.2
50
0
40
20
1.5 1.8 2.1 2.4
60
90
120
150
180
210
10 15 20 25 30 35 40
2.5 5 7.5 100
0
4
2
0 U.S.GPM
0
020304050607080910111213
15
17
19
21
23
25
27
30
33
36
Eta
NPSH
0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4
0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4
Eta[%]
NPSH[m]
P2[KW]
0.00
0.02
0.04 P2
Q[m³/h]
H[m]
Q[m³/h]
Q[l/min]
AVC/I/S - 1MISO 9906 Annex A
50HZ 2850rpm
Q[m³/h]
www.evak-pumps.com 14
EVAK PUMP TECHNOLOGY CORP.
Performance Curve
AVC,AVI,AVS-Series 50HZ Vertical Multistage CentrifugalIn-line Pumps
AVC,AVI,AVS-Series 50HZ Vertical Multistage CentrifugalIn-line Pumps
All technical information is subject to change without notice.
Eta[%]
NPSH[m]
Q[m³/h]
H[m]
Q[m³/h]
Q[l/min]
AVC/I/S - 3MISO 9906 Annex A
50HZ 2850rpm
Q[m³/h]
04
06
10
21
23
25
29
31
1 2 3 4
1 2 3 4
60
30 40 50 60 70
10 15 20
1
02
P2[KW]
0.00
0.02
0.04
0.06P2
30
0 1 2 3 4
0
0
40
20
60
90
120
150
180
210
10 20
5
0
3
2
0 U.S.GPM
0
Eta
NPSH
0
0
240
111213
15
17
19
33
36
27
08
05
09
03
07
Dimensions & Weights AVI/S-1M
AVI/AVS-1M02AVI/AVS-1M03AVI/AVS-1M04AVI/AVS-1M05AVI/AVS-1M06AVI/AVS-1M07AVI/AVS-1M08AVI/AVS-1M09AVI/AVS-1M10AVI/AVS-1M11AVI/AVS-1M12AVI/AVS-1M13AVI/AVS-1M15AVI/AVS-1M17AVI/AVS-1M19AVI/AVS-1M21AVI/AVS-1M23AVI/AVS-1M25AVI/AVS-1M27AVI/AVS-1M30AVI/AVS-1M33AVI/AVS-1M36
AVI/S-1MPump Type Motor Dimension (mm)
P2 DINflange
VictaulicH1 D1H2 H2 D2
Net weight(kg)
kwDIN flangeH1 VictaulicHP
0.50.50.50.50.50.5
0.750.750.750.75
111
1.51.51.51.522233
19.319.319.720.120.420.821.722.022.422.825.225.626.328.128.829.630.439.840.641.745.646.7
20.220.320.621.021.421.722.623.023.323.726.126.527.229.129.830.631.340.841.542.646.647.7
115115115115115115115115115115115115115115115115115141141141141141
141141141141141141141141141141141141141141141141141177177177177177
477477495513531549567585603621685703739775811847883991
1027108111351189
282282300318336354372390408426450468504540576612648700736790844898
452452470488506524542560578596660678714750786822858966
1002105611101164
257257275293311329347365383401425443479515551587623675711765819873
0.370.370.370.370.370.370.550.550.550.550.750.750.751.11.11.11.11.51.51.52.22.2
H1
H2
D2
G1/2
G1/2 G1/2
Flange(DIN-ANSI-JIS)PN25/DN25/32
D1
Victaulic
www.evak-pumps.com 16
EVAK PUMP TECHNOLOGY CORP.
Dimensions & Weights AVI/S-3M
All technical information is subject to change without notice.
AVI/AVS-3M02AVI/AVS-3M03AVI/AVS-3M04AVI/AVS-3M05AVI/AVS-3M06AVI/AVS-3M07AVI/AVS-3M08AVI/AVS-3M09AVI/AVS-3M10AVI/AVS-3M11AVI/AVS-3M12AVI/AVS-3M13AVI/AVS-3M15AVI/AVS-3M17AVI/AVS-3M19AVI/AVS-3M21AVI/AVS-3M23AVI/AVS-3M25AVI/AVS-3M27AVI/AVS-3M29AVI/AVS-3M31AVI/AVS-3M33AVI/AVS-3M36
AVI/S-3MPump Type Motor Dimension (mm)
P2 DINflange
VictaulicH1 D1H2 H2 D2
Net weight(kg)
kwDIN flangeH1 Victaulic
0.50.50.50.5
0.750.75
111
1.51.51.51.52233333444
477477495513531549613631649667685703739847883919955991
10271063112811641218
20.220.320.621.021.922.224.625.025.426.927.227.628.337.838.542.142.943.644.345.153.053.754.8
19.319.319.720.120.921.323.724.024.425.926.326.727.436.937.641.241.942.643.444.152.052.853.9
115115115115115115115115115115115115115141141141141141141141147147147
141141141141141141141141141141141141141177177177177177177177197197197
282282300318336354378396414432450468504556592628664700736772812848902
452452470488506524588606624642660678714822858894930966
10021038110311391193
257257275293311329353371389407425443479531567603639675711747787823877
0.370.370.370.370.550.550.750.750.751.11.11.11.11.51.52.22.22.22.22.2333
HP
AVC,AVI,AVS-Series 50HZ Vertical Multistage CentrifugalIn-line Pumps
AVC,AVI,AVS-Series 50HZ Vertical Multistage CentrifugalIn-line Pumps
H1
H2
D2
G1/2
G1/2 G1/2
D1Victaulic
Flange(DIN-ANSI-JIS)PN25/DN25/32
Dimensions & Weights AVC-3M
AVC-3M02AVC-3M03AVC-3M04AVC-3M05AVC-3M06AVC-3M07AVC-3M08AVC-3M09AVC-3M10AVC-3M11AVC-3M12AVC-3M13AVC-3M15AVC-3M17AVC-3M19AVC-3M21AVC-3M23AVC-3M25AVC-3M27AVC-3M29AVC-3M31AVC-3M33AVC-3M36
AVC-3MPump Type Motor Dimension (mm)
P2 DINflange
DIN flangeH1 D1H2 D2
Net weight(kg)
kw0.50.50.50.5
0.750.75
111
1.51.51.51.52233333444
141141141141141141141141141141141141141177177177177177177177197197197
23.423.423.824.225.025.427.928.328.730.230.530.931.641.041.845.346.146.847.648.356.657.458.5
115115115115115115115115115115115115141141141141141141141141147147147
474474492510528546610628646664682700736844880916952988
10241060112511611215
279279297315333351375393411429447465501553589625661697733769809845899
0.370.370.370.370.550.550.750.750.751.11.11.11.11.51.52.22.22.22.22.2333
HP
H1
G1/2 G1/2
H2
D1D2
G1/2
Flange(DIN-ANSI-JIS)PN25/DN25/32
www.evak-pumps.com 18
EVAK PUMP TECHNOLOGY CORP.
Dimensions & Weights AVC-5M
AVC,AVI,AVS-Series 50HZ Vertical Multistage CentrifugalIn-line Pumps
AVC,AVI,AVS-Series 50HZ Vertical Multistage CentrifugalIn-line Pumps
All technical information is subject to change without notice.
AVC-5M02AVC-5M03AVC-5M04AVC-5M05AVC-5M06AVC-5M07AVC-5M08AVC-5M09AVC-5M10AVC-5M11AVC-5M12AVC-5M13AVC-5M14AVC-5M15AVC-5M16AVC-5M18AVC-5M20AVC-5M22AVC-5M24AVC-5M26AVC-5M29AVC-5M32AVC-5M36
AVC-5MPump Type Motor Dimension (mm)
P2 DINflange
DIN flangeH1 D1H2 D2
Net weight(kg)
kw D3HP0.5
0.750.75
11.51.51.52233333344
5.55.55.55.57.57.5
279306333366393420447490517544571598625652679737791845899953
103411451253
23.324.224.827.429.129.630.139.339.943.243.744.244.845.245.854.355.559.860.862.764.690.192.6
------------------------------------------
300300
115115115115115115115141141141141141141141141147147161161161161197197
141141141141141141141177177177177177177177177197197220220220220235235
474501528601628655682781808835862889916943970
10531107117112251279136015071615
0.370.550.550.751.11.11.11.51.52.22.22.22.22.22.2334444
5.55.5
H1
G1/2 G1/2
H2
D1
D2
G1/2
D3
Flange(DIN-ANSI-JIS)PN25/DN25/32
Performance Curve U.S.GPM
Eta[%]
NPSH[m]
P2[KW]
Q[m³/h]
H[m]
Q[m³/h]
Q[l/min]
Q[m³/h]
12
15
90
120
210
0.00
0.04
0.08
0.12P2
0 5
0
0
40
20
30
150
10
0
2
1
0
0
Eta
NPSH
240
1 2 3 4 6 7 8 9
0 51 2 3 4 6 7 8 9
0 51 2 3 4 6 7 8 9
60
180
60
3
4020 8060 120100 140
20 30 40
AVC/I/S - 5MISO 9906 Annex A
50HZ 2850rpm
03040506070809
02
1011
1314
16
20
18
22
24
26
29
32
36
www.evak-pumps.com 20
EVAK PUMP TECHNOLOGY CORP.
Performance Curve
AVC,AVI,AVS-Series 50HZ Vertical Multistage CentrifugalIn-line Pumps
AVC,AVI,AVS-Series 50HZ Vertical Multistage CentrifugalIn-line Pumps
All technical information is subject to change without notice.
Eta[%]
NPSH[m]
Q[m³/h]
H[m]
Q[m³/h]
Q[l/min]
Q[m³/h]
P2[KW]
U.S.GPM
30
0 2 4
500
0
40
20
6 8
60
90
120
150
180
210
10
0
4
2
0
0
NPSH
0
0
10 12
240
100 150 200
20 30 40 50 60
60
6
2 4 6 8 10 12
2 4 6 8 10 12
06
10
0.0
0.1
0.2
0.3P2
AVC/I/S - 10MISO 9906 Annex A
50HZ 2850rpm
Dimensions & Weights AVI/S-5M
AVI/AVS-5M02AVI/AVS-5M03AVI/AVS-5M04AVI/AVS-5M05AVI/AVS-5M06AVI/AVS-5M07AVI/AVS-5M08AVI/AVS-5M09AVI/AVS-5M10AVI/AVS-5M11AVI/AVS-5M12AVI/AVS-5M13AVI/AVS-5M14AVI/AVS-5M15AVI/AVS-5M16AVI/AVS-5M18AVI/AVS-5M20AVI/AVS-5M22AVI/AVS-5M24AVI/AVS-5M26AVI/AVS-5M29AVI/AVS-5M32AVI/AVS-5M36
AVI/S-5MPump Type Motor Dimension (mm)
P2 VictaulicNet weight(kg)
DIN flange DINflangeH1 D1H2 H2 D2kw H1 VictaulicD3HP
0.50.750.75
11.51.51.52233333344
5.55.55.55.57.57.5
115115115115115115115141141141141141141141141147147161161161161197197
20.121.221.824.326.026.527.136.436.940.340.841.441.942.543.051.352.556.857.858.960.685.888.1
19.220.320.823.425.125.626.135.436.039.339.940.441.041.542.150.351.655.856.958.059.784.987.1
------------------------------------------
300300
141141141141141141141177177177177177177177177197197220220220220235235
477504531604631658685784811838865892919946973
10561110117412281282136315101618
282309336369396423450493520547574601628655682740794848902956
103711481256
452479506579606633660759786813840867894921948
10311085114912031257133814851593
257284311344371398425468495522549576603630657715769823877931
101211231231
0.370.550.550.751.11.11.11.51.52.22.22.22.22.22.2334444
5.55.5
H1
H2
D1
D2
G1/2
G1/2 G1/2
D3
Victaulic
Flange(DIN-ANSI-JIS)PN25/DN25/32
0102030405
070809
12
14
16
18
20
22
Eta
www.evak-pumps.com 22
EVAK PUMP TECHNOLOGY CORP.
Dimensions & Weights AVI/S-10M
All technical information is subject to change without notice.
Dimensions & Weights AVC-10M
AVC-10M01AVC-10M02AVC-10M03AVC-10M04AVC-10M05AVC-10M06AVC-10M07AVC-10M08AVC-10M09AVC-10M10AVC-10M12AVC-10M14AVC-10M16AVC-10M18AVC-10M20AVC-10M22
AVC-10MPump Type Motor Dimension (mm)
P2 DINflange
DIN flangeH1 D1H2 D2
Net weight(kg)
kw D30.51
1.5233444
5.55.57.57.5101010
----------------------
300300300300300
35.938.240.350.153.955.063.864.965.970.372.4
104.1106.2113.6116.7118.8
115115115141141141147147147161161197197197197197
141141141177177177197197197220220235235235235235
538582612714744774834864894934994
11221182127813381398
343347377423453483518548578608668760820880940
1000
0.370.751.11.52.22.233344
5.55.57.57.57.5
HP
G1/2G1/2
G1/2
H2
H1
D2
D1
D3
Flange(DIN-JIS)PN16-25/DN40
D3
H1
H2
D2
D1
G1/2
G1/2
G1/2
G1/2
Victaulic
Flange(DIN-ANSI-JIS)PN16-25/DN40
AVI/AVS-10M01AVI/AVS-10M02AVI/AVS-10M03AVI/AVS-10M04AVI/AVS-10M05AVI/AVS-10M06AVI/AVS-10M07AVI/AVS-10M08AVI/AVS-10M09AVI/AVS-10M10AVI/AVS-10M12AVI/AVS-10M14AVI/AVS-10M16AVI/AVS-10M18AVI/AVS-10M20AVI/AVS-10M22
AVI/S-10MPump Type Motor Dimension (mm)
P2 DINflange
VictaulicH1 D1H2 H2 D2
Net weight(kg)
kw
DIN flangeH1 VictaulicD3HP
0.51
1.5233444
5.55.57.57.5101010
----------------------
300300300300300
31.434.236.346.049.850.858.960.061.065.467.5
100.3102.4110.8112.8114.9
31.634.336.446.150.051.059.160.161.165.667.6
100.4102.5110.9113.0115.1
115115115141141141147147147161161197197197197197
141141141177177177197197197220220235235235235235
548592622724754784844874904944
100411321192128813481408
353357387433463493528558588618678770830890950
1010
548592622724754784844874904944
100411321192128813481408
353357387433463493528558588618678770830890950
1010
0.370.751.11.52.22.233344
5.55.57.57.57.5
AVC,AVI,AVS-Series 50HZ Vertical Multistage CentrifugalIn-line Pumps
AVC,AVI,AVS-Series 50HZ Vertical Multistage CentrifugalIn-line Pumps
www.evak-pumps.com 48
EVAK PUMP TECHNOLOGY CORP.
Install Mechanical Seals
AVC/AVI/AVS 1M,3M,5M Coupling adjustment
AVC/AVI/AVS 10M,15M,20M Coupling adjustment
AVC/AVI/AVS 32M,45M,64M,90M Coupling adjustment
AVC,AVI,AVS-Series 50HZ Vertical Multistage CentrifugalIn-line Pumps
Troubleshooting
Fault Possible cause1.Pump does not run when the motor starter is activated.
Possible solutionCheck connections or restart the power supply.Reconnect or replace contacts or magnetic coil.
Replace fuses.Clean the obstruction and restart pump.
Replace the motor.Reset the motor or thermal protector. Check the water level in the tank or the water system pressure. If everything is in order, check the protection device and its connection cables.
Set the motor starter correctly.Fasten or replace the cable connection.Replace fuse and try starting again.Check and clean obstruction from system.Replace motor starter contacts.Replace the motor.Check the power supply.
Check the operating conditions of the pump. Protect the control panel from heat sources and from the sun.Check the power supply.
Replace motor bearings.Partially close the on-off valve located discharge side until the delivery rate returns to within the specified limits.Disassemble and clean the pump and piping.
Check the actual power requirements based on the characteristics of the liquid being pumped, and replace the motor accordingly.
Fill the pump with the liquid to be pumped.Clean the pump, suction or discharge pipe.
Replace the foot or check valve.Repair or replace the suction pipe.Remove trapped air from system.Change the direction of rotation of the motor by reversing motor connections.
2.Starter overload trips immediately when the power is switched on.
3.The pump starts but, after a short time, the thermal protec-tor trips out or the fuses blow.4.The pump starts up but, after aperiod of time, the thermal protector trips.protector trips out or the fuses blow.
5.Pump runs but no water delivered.
a. Supply failure or no power supply. b. Main contacts in motor starter are not making contact
or the motor coils are defective c. Pump or auxiliary circuits protection fuses blown. d. Pump or piping system may be obstructed causing a jam. e. Motor may have failed. f. Motor protector or thermal relay has tripped out. g. Tripping of anti-dry running protection.
a. Overload setting is too low. b. The cable connection is loose or faulty. c. One fuse is blown. d. Pump is jammed by an obstruction e. Contacts in overload are faulty. f. The motor winding is defective. g. Low voltage (Especially at peak time).
a. The voltage is not within the motor’s operating limits.b. The control panel is situated in an excessively heated area or is exposed to direct sunlight. c. A phase in the power supply is missing.
a. Worn motor bearings causing motor to overheat. b. The pump’s delivery rate is higher than the specified rate on the pump nameplate.
c. There are obstructions inside the pump or pumping system.d. Less viscous liquids may cause the motor to work too hard and overload the motor, causing the motor to overheat.
a. Pump is not primed with liquid. b. The pump, suction or discharge pipes are blocked by solids in the liquid being pumped. c. The foot or check valve is blocked or has failed. d. The suction pipe leaks. e. The air is in the suction pipe or pump. f. Motor operating in wrong direction (three-phase motor)a. The pump draws in air or the inlet pressure is too low. b. The pump or the suction side of the piping system partly blocked by foreign bodies.
Short circuit.
a. The foot or the check valve has failed. b. Leakage in the suction pipe.
a. Leakage in the foot valve, check valve or system. b. Ruptured membrane or no air pre-charge in surge tank.
a. Cavitation
b. Make sure that pump and motor shafts are properly aligned.c. Worn motor bearings.d. Operation with frequency converter.
e. Check vibration and noise damping devices
6.The pump capacity is not constant.
Improve the suction conditinos.Clean the pump or suction pipe.
Check electrical system.
Check and replace check valve.Repair or replace the suction pipe.
Repair or replace the components. See relevant instructions in surge tank’s manual.
Reduce the required flow or improve the operating conditions of the pump (suction conditions, head, flow resistance, liquid temperature, viscosity … etc.). Adjust the pump and/or motor shafts.
Replace the bearings or the motor. Consult a qualified engineer form the supplier of the frequency converter.Replace vibration & noise dampers, if worn.
7.The system's general protection cuts in.8.The pump rotates in the wrong direction when switched off.9.The frequency of Pump start-up is too high.
10.Vibration and noise
www.evak-pumps.comEvak Pump Technology Corp.
Model :
H :MEI ≥
Hmax :
Pmax/Tmax :
m Q : m³/h
n :
S.No. : Made in Taiwan
m
P2 : F.L.A. :KW HP
Supply : V HZ PHType :
Bar/°C :
m-1
pumps & pumps
www.evak-pumps.com 50
EVAK PUMP TECHNOLOGY CORP.
Nameplate
1.Pump Model2.Pump Type3.Rated Power4.Eletric Current5.Speed6.Maximum Head7.Rated Capacity8.Rated Head9.Maximum Operating Pressure10.Rotating Direction 11.Serial Number12.Voltage13.Minimum Efficiency Index
2
64
109
3
112
8135
11
7
AVC,AVI,AVS-Series 50HZ Vertical Multistage CentrifugalIn-line Pumps
AVC,AVI,AVS-Series 50HZ Vertical Multistage CentrifugalIn-line Pumps