Post on 13-Jul-2020
ETERNUS JX60
Technical Product Introduction
0 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
Highlights
The ETERNUS JX60 passive
storage subsystem accommodates
up to 240 HDDs
3.5" SAS 2.0 Nearline SAS 7200 rpm,
max. storage capacity 960 TB 1)
One or two 6 Gbit/s SAS interfaces for host server connection
A maximum of two enclosures can be daisy-chained
Can be used as a JBOD or RAID system
RAID functionality provided by the controller in the host server
Certified for Windows 2012 R2 Storage Spaces
1 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
1) At the time of publication using four enclosures fully populated with 4 TB disks
Overview
Disk bays per enclosure 60
Disk technology SAS 2.0
Max. number of enclosures per server 4
When both channels of the HBA/RAID Controller are used
I/O Modules (IOM) 1 or 2
Power Supply Units (PSU) 4
Fan Expander Modules (FEM) 2
Maximum number of host servers 1 (2 in cluster config.)
Height unit standard 4 U
2 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
Technical Overview
Technical Product Introduction ETERNUS JX60 Copyright Fujitsu, Release June 2014 3
Shipment Contents
4 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
ETERNUS JX60
Setup and Installation poster
Rackmount kit
Drive Enclosure
(with front bezel mounted)
4 power cords
2 AC cables 2.5 m
2 AC cables 4.0 m
Safety Manual
Rack installation tool
(two pieces, fitted
underneath the system)
Rack Mount Kit
5 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
Flap Bracket
Cable Management Arm
Screws
Left rail
Right rail
Cable ties
(black/green) Aluminium blocks
Unpacking and Packing
Always retain the original packaging of the storage subsystem for possible
further transport
The storage subsystem should be transported only in its original
packaging or other suitable packaging for protecting it against transport
damage
Please note that the above is also valid for
spare parts, including defective disks
Please observe the acclimatization times
before connecting the system to mains
power
6 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
Temperature
difference °C
Min. acclimatization
time (hours)
5 3
10 5
15 7
20 8
25 9
30 10
Rack Installation
For complete instructions please refer to the Operating Manual and/or to
the Setup and Installation poster supplied with the system
7 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
Rack installation tool
Minimum required rack depth for the
installation of the JX60 is 1050 mm
Removing the rack installation tool
8 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
Place holder for video clip RackInstallation.wmv
Rack Mount
It is strongly recommended to fit an anti-tilt bracket on the rack during the
installation and to use it always when an enclosure is pulled out from the
rack
The supplied Cable Management Arm,
Flap Bracket and cable ties provide
appropriate cable management
9 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
Cabling
Two types of cables available
SAS cables for host connection
• Available in lengths of 3 and 6 meters (ca. 10 and 20 feet)
• Host SAS cables have two different types of connectors
• Mini SAS connector for the host connection (SFF8088)
• Mini SAS HD connector for connecting to the JX60 (SFF8644)
SAS cables for cascading
2.5, 3.5 and 6 meters (ca. 8, 12 and 20 feet)
Both cable ends equipped with the same
connector type
Cables are connected to the JX60 with
the cable tab on the underside
10 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
SFF8088
SFF8644
11 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
Place holder for video clip Cabling.wmv
Installation
For complete step-by-step installation instructions please refer to the
Setup and Installation poster or the Operating Manual
Unpack the storage subsystem
Mount the storage subsystem in the rack
Cabling
Connect the system to mains voltage
• Ensure that at least two PSUs of the JX60 and one PSU of the host server are connected with the
same phase
• For phase redundancy the PSUs of the JX60 must be pairwise connected to two different phases or
rack power circuits
Switch on the host server
• Fitted with a SAS RAID Controller or SAS HBA
• Only released SAS RAID / HBA are supported, please see MatrixEP for reference
• The storage subsystem switches automatically on when SAS signal is detected
12 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
Exterior View Front
13 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
DE ID
Sequential Enclosure number
between 01 and 04
Identify LED
Blinking blue = Locate function activated
using ServerView
Power LED
Green = DC power supply is
in normal status
Fault LED
Amber = The system is in
warning or error status
Disk Status LED
Green or blinking green = Disk is in
normal status
Amber = Disk is in error status
OR
Locate functionality enabled with ServerView Disk Activity Panel Operation Panel
Identify LED
Power LED
Fault LED Disk Status LED
DE ID
14 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
Place holder for video clip ExteriorViewFront.wmv
Exterior View Rear
15 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
FEM#1
PSU#1
PSU#3
IOM#1
FEM#0
PSU#0
PSU#2
IOM#0
SAS IN SAS OUT SAS IN SAS OUT
FEM = Fan Expander Module
IOM = I/O Module
PSU = Power Supply Unit
16 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
Place holder for video clip ExteriorViewRear.wmv
I/O Module (IOM)
Connects the JX60 with the host server
One or two IOMs per enclosure
Supports 6 Gb/s host transfer rate
Hot replaceable
Requires dual IOM configuration
• Always use proper ESD protection (wrist strap) during replacement to avoid causing damage to the
unit
• Before removal it must be ensured that all server data transfer to the failed unit is stopped to avoid
loss of data
• For complete replacement instructions please refer to the Operating Manual or the Service
Supplement
17 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
IOM Exterior View
18 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
In Link
Fault LED
Out Link
Fault LED
In Link LED SAS In Port SAS Out Port Out Link LED Ready LED Fault LED Identify LED
Eject lever
locking latch
Eject lever In Link LED
Green = Link established
In Link Fault LED
Amber = The link between the In Port
and the source is in error status
Out Link LED
Green = Link established
Out Link Fault LED
Amber = The link between the Out Port
and the destination is in error status
Fault LED
Amber = The I/O module is
in error status
Ready LED
Green = The I/O module is
in normal status
Identify LED
Blinking blue = Locate function
activated using
ServerView
Eject lever locking latch
Need to be pushed sideways to
be able to use the eject levers
Eject lever
Pulled outward to remove the module
19 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
Place holder for video clip IOMExteriorView.wmv
Power Supply Unit (PSU)
Four redundant 80 Plus Gold (92%) PSUs as standard
It is recommended to use separate power sources for a pair of PSUs Two phases or two different circuits of the rack installation
Recommended to have at least two of the JX60 PSUs and one of the host server PSUs
connected to the same phase
Hot Plug replaceable Always use proper ESD protection (wrist strap) during replacement to avoid causing
damage to the unit
Do not leave removed for longer than 5 minutes to ensure normal cooling of the system
For complete replacement instructions please refer to the Operating Manual or the
Service Supplement
No power on/off switch, system is switched on and off by detection of the
SAS signal
20 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
PSU Exterior View
21 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
Fault LED Power LED AC Missing LED Fan Fail LED Power cable
locking strap
Fault LED
Amber = DC power is not supplied by the PSU
Power LED
Green = AC power is supplied to the PSU
AC Missing LED
Amber = AC power is not supplied to this PSU but to another PSU
Fan Fail LED
Amber = The PSU or the fan in the PSU is in error status
Power cable locking strap
Can be applied to prevent accidental removal
of power cable
22 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
Place holder for video clip PSUExteriorView.wmv
Fan Expander Module (FEM)
Contains two SAS Expanders that provide the system internal interface
between the IOM and the disks
Two integrated cooling fans
Hot Plug replaceable
Requires dual IOM configuration
• Always use proper ESD protection (wrist strap) during replacement to avoid causing damage to the
unit
• When replacing, do not leave removed for longer than 5 minutes to ensure normal cooling of the
system
• For complete replacement instructions please refer to the Operating Manual or the Service
Supplement
23 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
FEM Exterior View
24 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
Fault LED Ready LED
Fault LED
Amber = The module is in error status
Ready LED
Green = The module is in normal status
Module Overview
25 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
Rear of the system
IOM
(I/O Module)
FEM
(Fan Expander
Module)
Cable Management Arm
PSU
(Power Supply Unit)
Flap Bracket
Hard Disk Drives (1)
Maximum of 60 disks per enclosure
1) Nearline SAS
2.0, 4 TB / 3 TB / 2 TB, 7200 rpm, 3.5"
Different capacities can be mixed in
the same enclosure
Drives of an ETERNUS DX High
Density Drive Enclosure are not
compatible with the disks of the JX60
All disk slots must be fitted either
with a disk or a dummy drive
26 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
1) All capacities at the time of publication
Front
Disk numbering from top left to bottom right
Hard Disk Drives (2)
To access the disks
Release the locking
latches on each side
of the front panel
Pull out the enclosure
Release the green
cover locking latches
and swing the cover
to the left
27 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
Fault LED
Amber = The hard disk is in error status
OR
Locate functionality
enabled with ServerView Hard Disk Frame
Rear
Front Locking lever
Fault LED
Hard Disk Drives (3)
Hot replacement supported if the disk belongs to a faultless and fault-
tolerant RAID Group of the host server RAID controller
Replacement allowed only when the disk is inactive
• Or marked defective in the ServerView RAID Manager
First pull the disk out only to disconnect it, then wait 60 seconds for the Host Bus Adapter
to recognize the removal and to let the disk spin down
• After removing from the disk slot, do not leave a disk removed for longer than 5 minutes to ensure
normal cooling of the system
28 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
29 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
Place holder for video clip ReplaceDisk.wmv
SAS RAID Controller / Host Bus Adapter
LSI MegaRAID SAS9286CV-8e
x8 lane PCIe 3.0, Full Height and Low Profile, 1 GB cache with ECC, 8 external ports with
up to 6.0 Gb/s transfer rate per port
Supported RAID levels
• 0, 1, 10, 5, 50, 6, 60
Supports Dedicated and Global Hot Spare
ServerView RAID Manager for RAID configuration
LSI SAS9200-8e
x8 lane PCIe 2.0, Full Height and Low Profile
6 Gb/s SAS 2.0, 8 external ports
For up-to-date list of qualified PRIMERGY servers, RAID controllers and
SAS HBAs please refer to the MatrixEP tool
30 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
Host Server Connection (1)
Basic RAID controller / HBA configuration
Redundant configuration 1)
31 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
Second shelf optional
1) Not supported for RAID Controller at initial product release, please refer to MatrixEP for up-to-date status
Identification
The system serial number can be found on the
extractable tab in the front of the system and
on the identification label located on the
system cover in the rear of the system
For system identification, the
first five digits of the serial
number are: JWXTD
32 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
Rear
Front
Location of the identification label
33 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
Place holder for video clip Identification.wmv
Management
Fujitsu ServerView support
The Agents from ServerView Suite DVD are required on the connected server
Uses SES1) protocol over in-band SAS for the monitoring features
• Module status
• IOM, PSU, FEM
• Module and system temperatures
• Hard disk status
ServerView RAID Manager
• V5.8.8 or later
34 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
1) SCSI Enclosure Services
35 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
Place holder for video clip Management.wmv
OS Support
Supported Operating Systems 1)
Windows Server • 2012 R2, Server 2012, 2008 SP2, 2008 SP2 (x64), 2008 R2 (x64)
SuSE Linux Enterprise Server • 10 SP4, 10 SP4 EM64T, 11 SP3, 11 SP3 EM64T
RedHat Enterprise Linux • 5 U10, 5 U10 EM64T, 6 U5 x86, 6 U5 x86_64
VMware vSphere • 5.1 Update 2, 5.5 Update 1
For up-to-date list of supported Operating Systems please refer to the MatrixEP
tool
The host server can be booted from the ETERNUS JX60 The boot functionality is PRIMERGY dependent and is limited to certain HBAs and slots, please refer to
the respective PRIMERGY documentation
36 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
1) At the time of publication
Manuals and Support Information
Operating Manual
Features, technical data, troubleshooting, installation/removal of all Hot Plug components
http://support.ts.fujitsu.com/manuals/
or
https://partners.ts.fujitsu.com/com/service/ps/Storage/disc/ETERNUS_JX/JX60/Pages/def
ault.aspx
FTS_ETERNUSJX60OperatingManual_EditionJune2014_1110971.PDF
Service Supplement
Replacing components
https://partners.ts.fujitsu.com/com/service/ps/Storage/disc/ETERNUS_JX/jx60/Pages/defa
ult.aspx
tm-JX60-SS-en.pdf
37 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
Configuration Tool
There are three configurable items for the ETERNUS JX60
IOM
• Single or dual IOM
Hard disks
SAS cable
• Please note that the base configuration does not contain any SAS cables
SystemArchitect
Configuration tool for generating an order number
https://partners.ts.fujitsu.com/com/order-supply/configurators/pc-system-
architect/Pages/default.aspx
38 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
Service and Support
Technical Product Introduction ETERNUS JX60 Copyright Fujitsu, Release June 2014 39
Electrostatic Precautions
Discharge static electricity from your body (for example by touching a grounded
metal object) before handling modules containing electrostatic sensitive
components
The equipment and tools you use must be free of static charge
Remove the power plug before installing or removing modules containing
electrostatic-sensitive components
Only hold modules containing electrostatic-sensitive components by their edges
Do not touch any of the pins or track conductors on a module containing
electrostatic-sensitive components
Use a grounding strap designed for the purpose, to connect you to the system unit
as you install the modules
Place all components on a static-safe base
40 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
CRUs
Customer Replaceable Units
Hot replaceable
• Hard Disk Drive
For detailed replacement instructions refer to the Operating Manual
41 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
FRUs
Field Replaceable Units
Hot replaceable FRUs
• Input/Output Module (IOM)
• Pre-requisites; Two IOMs, Single server connection, Path redundancy
• Fan Expander Module (FEM)
• Pre-requisites; Two IOMs, Single server connection, Path redundancy
• Power Supply Unit (PSU)
• Hard Disk Drive
Not hot replaceable FRUs
• Operating Panel
• Disk Activity Panel
• Mid-plane and Back-plane
• To replace the Mid-plane or Back-plane the complete housing needs to be replaced
For detailed replacement instructions refer to the Service Supplement 42 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
43 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60
Place holder for video clip ReplaceModule.wmv
Support Tools
MatrixEP
Supported servers and RAID controllers
https://partners.ts.fujitsu.com/com/products/servers/primergy/conftools/matrixep/Pages/de
fault.aspx
or
http://ts.fujitsu.com/matrixep
Spare part list ERSIN
https://partners.ts.fujitsu.com/com/service/general/service-
spares/ERSIN/Pages/default.aspx
Product class for the ETERNUS JX60
• PR85-FTS STORAGE GLOBAL