Post on 02-Nov-2014
description
Nokia Siemens Networks GSM/EDGE BSS, rel. RG10(BSS), operating documentation, issue 03
Connector Panels and External Cables in Flexi BSC and TCSM3i
DN70617303
Issue 1-0
2 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804bce7d
The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation.
The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given "as is" and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT.
This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only.
Copyright © Nokia Siemens Networks 2009. All rights reserved
f Important Notice on Product Safety Elevated voltages are inevitably present at specific points in this electrical equipment. Some of the parts may also have elevated operating temperatures.
Non-observance of these conditions and the safety instructions can result in personal injury or in property damage.
Therefore, only trained and qualified personnel may install and maintain the system.
The system complies with the standard EN 60950 / IEC 60950. All equipment connected has to comply with the applicable safety standards.
The same text in German:
Wichtiger Hinweis zur Produktsicherheit
In elektrischen Anlagen stehen zwangsläufig bestimmte Teile der Geräte unter Span-nung. Einige Teile können auch eine hohe Betriebstemperatur aufweisen.
Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Körperverlet-zungen und Sachschäden führen.
Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertes Personal die Anlagen installiert und wartet.
Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Angeschlossene Geräte müssen die zutreffenden Sicherheitsbestimmungen erfüllen.
DN70617303Issue 1-0
3
Connector Panels and External Cables in Flexi BSC and TCSM3i
Id:0900d805804bce7d
Table of ContentsThis document has 111 pages.
Summary of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101.1 Use of product names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101.2 Connector panels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101.3 Related information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111.4 Feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2 Connector panel types in the Flexi BSC . . . . . . . . . . . . . . . . . . . . . . . . 12
3 E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H) . . . 143.1 Connector panels CPETS-G and CPETS-H with RJ45 connectors. . . . 143.2 Flexi BSC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163.2.1 Optional cabling cabinet is not used . . . . . . . . . . . . . . . . . . . . . . . . . . . 163.2.2 Optional cabling cabinet is used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183.3 TCSM3i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 343.3.1 TCSM3i for stand-alone installation option . . . . . . . . . . . . . . . . . . . . . . 343.3.2 TCSM3i for combined BSC/TCSM installation option . . . . . . . . . . . . . . 39
4 E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F) . 404.1 Connector panels CPETS-E and CPETS-F with RJ45 connectors . . . . 404.2 Flexi BSC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 414.2.1 Optional cabling cabinet is not used . . . . . . . . . . . . . . . . . . . . . . . . . . . 424.2.2 Optional cabling cabinet is used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 444.3 TCSM3i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 594.3.1 TCSM3i for stand-alone installation option . . . . . . . . . . . . . . . . . . . . . . 604.3.2 TCSM3i for combined BSC/TCSM installation option . . . . . . . . . . . . . . 65
5 E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F). . 665.1 Connector panels CPETC-E and CPETC-F with D37 connector packs 665.2 Flexi BSC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 675.2.1 Optional cabling cabinet is not used . . . . . . . . . . . . . . . . . . . . . . . . . . . 685.2.2 Optional cabling cabinet is used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 695.3 TCSM3i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 845.3.1 TCSM3i for stand-alone installation option . . . . . . . . . . . . . . . . . . . . . . 845.3.2 TCSM3i for combined BSC/TCSM installation option . . . . . . . . . . . . . . 90
6 Roof panel with LAN, LPT/VDU, and synchronisation and alarm interfaces (CPRJ45-A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
6.1 LAN interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 916.1.1 1 Gbit/s optical uplink LAN cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 926.1.2 10/100 Mbit/s / 1 Gbit/s copper uplink LAN cables . . . . . . . . . . . . . . . . 926.2 External alarm cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 956.3 VDU/LPT peripheral cabling (LPT/VDU interfaces) . . . . . . . . . . . . . . . 1016.4 External synchronisation cabling (EXT SYNC interfaces) . . . . . . . . . . 103
7 Cabling panel with grounding outlets (CPGO) . . . . . . . . . . . . . . . . . . . 105
4 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804bce7d
8 Requirement specifications for external cables of M98 mechanics Flexi BSC and TCSM3i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
8.1 General requirements for connectors and cable materials . . . . . . . . . . 1068.2 Requirements for specified coaxial cable assemblies . . . . . . . . . . . . . 1068.2.1 E1 coaxial unbalanced PCM cable assembly . . . . . . . . . . . . . . . . . . . . 1068.2.2 Unbalanced (coaxial) external synchronisation cable assembly (CKB) 1068.3 Requirements for specified twisted pair cable assemblies . . . . . . . . . . 1078.3.1 10 Base-T /100 Base-TX / 1000Base-T/TX LAN cable assemblies (CNI and
cross-connected LAN cable). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1078.3.2 T1 (E1) balanced PCM cable assembly (CNIS) . . . . . . . . . . . . . . . . . . 1078.3.3 E1 balanced PCM cable assembly (CNIB) . . . . . . . . . . . . . . . . . . . . . . 1078.3.4 E1 balanced PCM cable assembly (CNIA) . . . . . . . . . . . . . . . . . . . . . . 1078.3.5 Current and voltage-controlled alarm cable assembly (CNDC) . . . . . . 1088.3.6 Alarm cable (CNDE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1088.3.7 Alarm cable (CYV) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1088.3.8 Alarm cable (CYR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1088.3.9 Electrical performance requirements for X.25 cable assemblies . . . . . 1088.3.10 Electrical performance requirements for optical LC cable assemblies (mul-
timode cable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1098.3.11 Electrical performance requirements for optical LC cable assemblies (sin-
glemode cable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
DN70617303Issue 1-0
5
Connector Panels and External Cables in Flexi BSC and TCSM3i
Id:0900d805804bce7d
List of FiguresFigure 1 Connector panel CPETS-G and CPSM cable (front view). . . . . . . . . . . 15Figure 2 Connector panel CPETS-H (front view) . . . . . . . . . . . . . . . . . . . . . . . . . 16Figure 3 RJ45 connector cable (CNIB cable type) with four connectors . . . . . . . 17Figure 4 RJ45 connector cable (CNIB cable type) with four connectors . . . . . . . 19Figure 5 RJ45 connector cable (CNIB cable type) with four connectors . . . . . . . 35Figure 6 Connector panel CPETS-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40Figure 7 Connector panel CPETS-F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41Figure 8 Single RJ45 connector cable (CNIS cable type) for T1 trunk cables. . . 43Figure 9 RJ45 connector cable (CNIA cable type) with four connectors . . . . . . . 43Figure 10 Single RJ45 connector cable (CNIS cable type) for T1 trunk cables. . . 45Figure 11 RJ45 connector cable (CNIA cable type) with four connectors . . . . . . . 46Figure 12 Single RJ45 connector cable (CNIS cable type) for T1 trunk cables. . . 61Figure 13 RJ45 connector cable (CNIA cable type) with four connectors . . . . . . . 61Figure 14 CPETC-E panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66Figure 15 CPETC-F panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67Figure 16 CPRD cable assembly (panel end connector mounted) . . . . . . . . . . . . 68Figure 17 CPRD cable assembly (panel end connector mounted) . . . . . . . . . . . . 70Figure 18 CPRD cable assembly (panel end connector mounted) . . . . . . . . . . . . 85Figure 19 D-connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87Figure 20 Panel CPRJ45-A with LAN, alarm, LPT/VDU, and synchronisation interfac-
es - seen from the front of the cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . 91Figure 21 Optical LC connectors, straight type . . . . . . . . . . . . . . . . . . . . . . . . . . . 92Figure 22 Installation of the EXAU-A; mounting on the wall, cabling, and setting the
buzzer jumpers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100Figure 23 Peripheral cables; CNM for VDU and CNP for LPT. . . . . . . . . . . . . . . 102Figure 24 CPGO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105Figure 25 Optical LC connectors, straight type . . . . . . . . . . . . . . . . . . . . . . . . . . 105
6 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804bce7d
List of TablesTable 1 BSC network elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Table 2 TCSM3i product family . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Table 3 Connector panels and the CPGO used in the Flexi BSC . . . . . . . . . . . . 12Table 4 E1 trunk cable connector, pin configuration . . . . . . . . . . . . . . . . . . . . . . 17Table 5 Recommended cable type for E1 trunk cables (CNIB) . . . . . . . . . . . . . 17Table 6 Balanced panel at the BSCC cabinet top in first deliveries . . . . . . . . . . 18Table 7 Balanced panel at the BSCC cabinet top in upgrade deliveries . . . . . . 18Table 8 Balanced connector panels for the BSC3i . . . . . . . . . . . . . . . . . . . . . . . 19Table 9 Recommended cable type for E1 trunk cables (CNIB) . . . . . . . . . . . . . 19Table 10 Balanced panels in first deliveries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Table 11 Balanced panels in upgrade deliveries . . . . . . . . . . . . . . . . . . . . . . . . . 27Table 12 Balanced connector panels for the TCSM3i . . . . . . . . . . . . . . . . . . . . . 35Table 13 Recommended cable type for E1 trunk cables (CNIB) . . . . . . . . . . . . . 35Table 14 CPETS-H balanced panels in the TCSM3i cabling cabinet - A-interface . .
36Table 15 CPETS-H balanced panels in the TCSM3i cabling cabinet - Ater-interface
38Table 16 E1 and T1 trunk cable connector, pin configuration . . . . . . . . . . . . . . . . 42Table 17 Recommended cable type for T1 trunk cables (CNIS) . . . . . . . . . . . . . 42Table 18 Recommended cable type for E1 trunk cables (CNIA) . . . . . . . . . . . . . 43Table 19 Balanced panel at the BSCC cabinet top in first deliveries . . . . . . . . . . 44Table 20 Balanced panel at the BSCC cabinet top in upgrade deliveries . . . . . . 44Table 21 Balanced connector panels in the cabling cabinet . . . . . . . . . . . . . . . . . 45Table 22 Recommended cable type for T1 trunk cables (CNIS) . . . . . . . . . . . . . 45Table 23 Recommended cable type for E1 trunk cables (CNIA) . . . . . . . . . . . . . 46Table 24 Balanced panels in first deliveries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46Table 25 Balanced panels in upgrade deliveries . . . . . . . . . . . . . . . . . . . . . . . . . 52Table 26 Balanced connector panels for the TCSM3i . . . . . . . . . . . . . . . . . . . . . 60Table 27 Recommended cable type for T1 trunk cables (CNIS) . . . . . . . . . . . . . 60Table 28 Recommended cable type for E1 trunk cables (CNIA) . . . . . . . . . . . . . 61Table 29 Balanced panels in the cabling cabinet - A-interface . . . . . . . . . . . . . . . 62Table 30 Balanced panels in the cabling cabinet - Ater-interface . . . . . . . . . . . . . 65Table 31 Unbalanced panel at the BSCC cabinet top in first deliveries . . . . . . . . 68Table 32 Unbalanced panel at the BSCC cabinet top in upgrade deliveries . . . . 69Table 33 Unbalanced connector panels for the Flexi BSC . . . . . . . . . . . . . . . . . . 69Table 34 Recommended cable type for E1 coaxial trunk cables (CPRD) . . . . . . 70Table 35 Unbalanced panels in first deliveries . . . . . . . . . . . . . . . . . . . . . . . . . . . 71Table 36 Unbalanced panels in upgrade deliveries . . . . . . . . . . . . . . . . . . . . . . . 76Table 37 Unbalanced connector panels for the TCSM3i . . . . . . . . . . . . . . . . . . . 85Table 38 Recommended cable type for E1 coaxial trunk cables (CPRD) . . . . . . 85Table 39 Unbalanced panels in cabling cabinet - A-interface . . . . . . . . . . . . . . . . 87Table 40 Unbalanced panels in cabling cabinet - Ater-interface . . . . . . . . . . . . . . 90Table 41 CNIX cable connector, pin configuration in 10/100 Mbit/s use (cross-con-
nected cable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92Table 42 CNIX cable connector, pin configuration in 1 Gbit/s use (cross-connected
cable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
DN70617303Issue 1-0
7
Connector Panels and External Cables in Flexi BSC and TCSM3i
Id:0900d805804bce7d
Table 43 CNI cable connector, pin configuration in 10/100 Mbit/s use (straight-con-nected cable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Table 44 CNI cable connector, pin configuration in 1 Gbit/s use (straight-connected cable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Table 45 Recommended cable types for LAN cables (CNI and CNIX) . . . . . . . . 94Table 46 External alarm cabling connectors in the CPRJ45-A panel . . . . . . . . . 95Table 47 Alarm signals at the CPRJ45-A panel and pin configuration of CNDE cable
with D25 connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95Table 48 Signals on panel connector 21 (Voltage and current-controlled AL inputs,
AEIx) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97Table 49 Signals on panel connector 23 (current-controlled ALS inputs) . . . . . . 98Table 50 General requirements for external alarm cable CNDE . . . . . . . . . . . . . 99Table 51 V.24/V.11 cable connector in the CPRJ45-A panel, pin configuration 101Table 52 Recommended cable types for V.24/V.11 cables (CNI) . . . . . . . . . . . 102Table 53 The pin configuration for connectors 18 and 19 . . . . . . . . . . . . . . . . . 103Table 54 Recommended cable types for synchronisation cables (CNI) . . . . . . 103Table 55 Pin configuration for connectors 20 and 28 . . . . . . . . . . . . . . . . . . . . 104Table 56 Main characteristics of optical singlemode cables and connectors . . 105Table 57 Main characteristics of optical multimode cables and connectors . . . 105
8 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804bce7d
DN70617303Issue 1-0
9
Connector Panels and External Cables in Flexi BSC and TCSM3i
Summary of changes
Id:0900d805804dcc03
Summary of changesChanges between document issues are cumulative. Therefore, the latest document issue contains all changes made to previous issues.
Issue 1-0The first issue of Connector Panels and External Cables in Flexi BSC and TCSM3i, based on Connector Panels and External Cables in BSC3i and TCSM3i. It is included in Flexi BSC first delivery and upgrade delivery documentation and in TCSM3i delivery documentation.
10 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804d3524
Overview
1 OverviewThis is a description of the connector panels and the related external cables used in the first-delivery Flexi BSC and in the upgrade-delivery Flexi BSC and in the TCSM3i.
The cabling connecting the equipment to the environment is treated from the point of view of the Flexi BSC and TCSM3i, indicating how and where the external wiring is con-nected to.
1.1 Use of product namesAcronyms related to Flexi BSC are presented in the following tables.
Acronyms related to TCSM3i are presented in the following table.
1.2 Connector panelsThe following connector panels and their external cabling are discussed in this docu-ment:
BSC = Base Station Controller, a general term for all BSC network elements
General name Product name Explanation
BSCi/BSC2i BSCi High capacity (upgraded) version of the first generation DX 200 BSC (BSCE)
BSC2i High capacity version of the second gener-ation DX 200 BSC2
Flexi BSC product family
BSC3i 660 660 TRX one cabinet configuration, upgradable to Flexi BSC
BSC3i 1000/2000 1000 TRX one-cabinet or 2000 TRX two-cabinet configuration, upgradable to Flexi BSC
Flexi BSC 3000 TRX one-cabinet configuration (S14)
Table 1 BSC network elements
TCSM3i high capacity transcoder submultiplexer, TCSM3i
Installation option Product name Explanation
TCSM3i for stand-alone installation option
TCSM3i high capacity transcoder submultiplexer, American National Standards Institute (ANSI) version of TCSM3i
ET interfaces in ANSI environment
TCSM3i for stand-alone installation option
TCSM3i high capacity transcoder submultiplexer, European Telecom-munications Standards Institute (ETSI) version of TCSM3i
ET interfaces in ETSI environment
TCSM3i for combined BSC/TCSM installation option
TCSM3i for combined BSC/TCSM installation option
STM-1/OC-3 inter-faces in the A-inter-face
Table 2 TCSM3i product family
DN70617303Issue 1-0
11
Connector Panels and External Cables in Flexi BSC and TCSM3i
Overview
Id:0900d805804d3524
• CPETS-G and CPETS-H (E1 balanced) • CPETS-E and CPETS-F (E1/T1 balanced) • CPETC-E and CPETC-F (unbalanced) • CPRJ45-A • CPGO
This document also contains Requirement specification for external cables of Flexi BSC equipment.
1.3 Related informationFor information on power distribution, site requirements, cabling and dimensioning prin-ciples of the Flexi BSC, see Installation Site Requirements for Flexi BSC product Family and TCSM3i, Engineering for Flexi BSC, and Engineering for TCSM3i.
1.4 FeedbackWe are always interested to know whether our manuals provide the information you need. If you have any comments about this document or any other manual, please pass them on to your local sales representative.
12 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804d0c7c
Connector panel types in the Flexi BSC
2 Connector panel types in the Flexi BSCThe site (outgoing external) cables enter the network element system through the con-nector panels. Most of the cables are terminated at the connector panels mounted in the cabling cabinet or at the equipment cabinet top (small CPETx, CPRJ45-A). Only the external STM-1/OC-3 trunk cabling and GigE Ethernet interface cabling is routed through the grounding outlets (CPGO).
The panels are connected by internal cabling through the cartridge back plane to the rear connectors of the Exchange Terminal plug-in unit ET16 (E1, T1, JT1), Clock and Tone Generator unit CL3TG-UA and the Hardware Alarm Terminal HWAT-B/-A or straight to the front connectors of SDH/SONET Exchange Terminal ETS2 and the LAN Switch plug-in units ESB24-A/ESB26.
The small CPETx panels used at the BSCC cabinet top are optional and ordered sepa-rately. The small and the large CPETx panels used in the optional cabling cabinet are delivered with the cabinet. Three cabling cabinet options are available:
• Cabling cabinet 2 PCMs / cable (connector panels CPETS-G and CPETS-H) • Cabling cabinet 1 PCM / cable (connector panels CPETS-E and CPETS-F) • Cabling cabinet coaxial PCMs (connector panels CPETC-E and CPETC-F)
Note that in Flexi BSC first deliveries, there is an additional small CPETx connector panel at the cabling cabinet top.
The panels mounted in the cabling cabinets are listed in the table below.
Panel type
Panel Connectors Description
CPETS-G 48 x E1
C111221
24 x RJ45, balanced, 2 x E1/RJ45
For balanced E1 trunk cables. Two external PCM lines are coupled to each RJ45 plug, which are terminated to the rear connectors of the ET16 Exchange Terminal plug-in units. Capacity 48 PCMs.
CPETS-E 48 x E1, T1, JT1
C109821
48 x RJ45, balanced For balanced E1, T1 or JT1 trunk cables. One external PCM line is coupled to each RJ45 plug, which are terminated to the rear connectors of the ET16 Exchange Terminal plug-in units. Capacity 48 PCMs.
CPETC-E 48 x E1
C109824
12 x 8 D-connector block unbalanced - coaxial 2 x SMD/E1
For unbalanced coaxial E1 trunk cables. One external PCM line is coupled to each pair of (Tx, Rx) SMD plugs, which are terminated to the rear connec-tors of the ET16 Exchange Terminal plug-in units. Capacity 48 PCMs.
Table 3 Connector panels and the CPGO used in the Flexi BSC
DN70617303Issue 1-0
13
Connector Panels and External Cables in Flexi BSC and TCSM3i
Connector panel types in the Flexi BSC
Id:0900d805804d0c7c
The external cables are connected to the connector panels; therefore, extra grounding devices are not needed.
CPETS-H 256 x E1
C111222
128 x RJ45, balanced, 2 x E1/RJ45
For balanced E1 trunk cables. Two external PCM lines are coupled to each RJ45 plug, which are terminated to the rear connectors of the ET16 Exchange Terminal plug-in units. Capacity 256 PCMs.
CPETS-F 256 x E1, T1, JT1
C109822
256 x RJ45, balanced For balanced E1, T1 or JT1 trunk cables. One external PCM line is coupled to each RJ45 plug, which are terminated to the rear connectors of the ET16 Exchange Terminal plug-in units. Capacity 256 PCMs.
CPETC-F 256 x E1
C109823
64 x 8 D-connector block unbalanced - coaxial 2 x SMD/E1
For unbalanced coaxial E1 trunk cables. One external PCM line is coupled to each pair of (Tx, Rx) SMD plugs, which are terminated to the rear connec-tors of the ET16 Exchange Terminal plug-in units. Capacity 256 PCMs.
CPRJ45-A 109825 16 x RJ45
2 x BNC
2 x D25
1 x D9
8 x LC
Interfaces for 100 Mbit/s and 1 Gbit/s LAN uplinks, LPTs and VDUs, incoming external syn-chronisation signals, and inputs and outputs for external alarms.
CPGO C104594
External STM-1/OC-3 trunk cables and GigE Ethernet inter-face cables
Panel type
Panel Connectors Description
Table 3 Connector panels and the CPGO used in the Flexi BSC (Cont.)
14 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804d10f1
E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H)
3 E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H)
3.1 Connector panels CPETS-G and CPETS-H with RJ45 con-nectorsThe small CPETx connector panel (CPETS-G) and the large CPETx connector panel (CPETS-H) are used for reducing site cabling as two external PCM lines are connected from each RJ45 connector. The panels fulfil E1 requirements. They can also be used for T1 interface if ANSI-specific line protection is not required.
The cabling of the CPETS-G panels is described in the cabling lists delivered in the Site Documents binder. The CPETS-G is installed at the BSCC cabinet top (one panel) or in the optional cabling cabinet (a total of four small panels, because there are three small panels in the cabinet and an additional small panel at the cabling cabinet top in first deliveries). The installation of the connector panel at the equipment cabinet top requires the use of Roof adapter (RACP) and the installation of the connector panel at the cabling cabinet top in first deliveries requires the use of Roof adapter 2 (RACP2).
For details of the panel, see figure Connector panel CPETS-G and CPSM cable (front view).
DN70617303Issue 1-0
15
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1 (PCM) balanced trunk cable panels (CPETS-G andCPETS-H)
Id:0900d805804d10f1
Figure 1 Connector panel CPETS-G and CPSM cable (front view)
The cabling of the CPETS-H panels is described in the cabling lists delivered in the Site Documents binder. The CPETS-H is installed in the optional cabling cabinet (two panels).
For details of the panel, see figure Connector panel CPETS-H (front view).
CPETS-G
Front view
Rear view
0
LINEALARMS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
ET16
CPSM
DN70457779
00
02
04
06
08
10
01
03
05
07
09
11
00
01
08
09
16
17
24
25
32
33
40
41
02
03
10
11
18
19
26
27
34
35
42
43
04
05
12
13
20
21
28
29
36
37
44
45
06
07
14
15
22
23
30
31
38
39
46
47
16 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804d10f1
E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H)
Figure 2 Connector panel CPETS-H (front view)
3.2 Flexi BSCDepending on the maximum number ET interfaces, the Flexi BSCi can be used either with or without a cabling cabinet.
3.2.1 Optional cabling cabinet is not usedThe optional cabling cabinet is not needed, if the number ET interfaces needed does not exceed 48.
00
01
08
09
16
17
24
25
32
33
40
41
02
03
10
11
18
19
26
27
34
35
42
43
04
05
12
13
20
21
28
29
36
37
44
45
06
07
14
15
22
23
30
31
38
39
46
4748
49
56
57
64
65
72
73
80
81
88
89
50
51
58
59
66
67
74
75
82
83
90
91
52
53
60
61
68
69
76
77
84
85
92
93
54
55
62
63
70
71
78
79
86
87
94
9596
97
104
105
112
113
120
121
128
129
136
137
98
99
106
107
114
115
122
123
130
131
138
139
100
101
108
109
116
117
124
125
132
133
140
141
102
103
110
111
118
119
126
127
134
135
142
143144
145
152
153
160
161
168
169
176
177
184
185
146
147
154
155
162
163
170
171
178
179
186
187
148
149
156
157
164
165
172
173
180
181
188
189
150
151
158
159
166
167
174
175
182
183
190
191192
193
200
201
208
209
216
217
194
195
202
203
210
211
218
219
196
197
204
205
212
213
220
221
198
199
206
207
214
215
222
223
224
225
232
233
240
241
248
249
226
227
234
235
242
243
250
251
228
229
236
237
244
245
252
253
230
231
238
239
246
247
254
255
CPETS-H
DN70458754
DN70617303Issue 1-0
17
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1 (PCM) balanced trunk cable panels (CPETS-G andCPETS-H)
Id:0900d805804d10f1
The E1 trunk cable connector and configuration is presented in the following table.
Recommended cable type for E1 trunk cables (CNIB) for the CPETS-G and CPETS-H is presented in the following table and figure.
Figure 3 RJ45 connector cable (CNIB cable type) with four connectors
The external trunk cable (from the ET panel) and the connector should meet the require-ments of the UL 1459 standard or the National Electrical Code ANSI/NFPA No.70. The connector should also meet the requirements of the FCC Part 68.
The following table shows the equipping order of the CPETS-G panel at the cabinet top in first deliveries.
Pin Signal Colour Remarks
1 R White/Blue Incoming direction # 1
2 T Blue
3 R White/Green Incoming direction # 2
4 R White/Orange Outgoing direction # 1
5 T Orange
6 T Green Incoming direction # 2
7 R White/Brown Outgoing direction # 2
8 T Brown
Table 4 E1 trunk cable connector, pin configuration
Cable type: 4x(4x2xAWG26/1) 120 Ω , insulated pairs, twisted, double-shielded, cross section 0.4 mm2
Cable connector: RJ45 modular connector plug (8-pole)
Table 5 Recommended cable type for E1 trunk cables (CNIB)
CONNECTOR
DN00206525
1 2 3 4
18 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804d10f1
E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H)
The following table shows the equipping order of the CPETS-G panel at the cabinet top in upgrade deliveries.
3.2.2 Optional cabling cabinet is usedThe cabling cabinet must be used, if more than 48 ET interfaces are needed.
ETC car-tridge
From SGC1C-A connector position
To CPETS-G connector position
Front ports in CPETS-G panel thorough this cable
Corresponding external ET numbers
ETC 0 B 19.1A B 00 00,01,02,03 ET368,ET369,ET370,ET371
ETC 0 B 19.1J B 01 04,05,06,07 ET372,ET373,ET374,ET375
ETC 0 B 19.1R B 02 08,09,10,11 ET376,ET377,ET378,ET379
ETC 0 B 19.1Z B 03 12,13,14,15 ET380,ET381,ET382,ET383
ETC 0 B 20.1A B 04 16,17,18,19 ET256,ET257,ET258,ET259
ETC 0 B 20.1J B 05 20,21,22,23 ET260,ET261,ET262,ET263
ETC 0 B 20.1R B 06 24,25,26,27 ET264,ET265,ET266,ET267
ETC 0 B 20.1Z B 07 28,29,30,31 ET268,ET269,ET270,ET271
ETC 0 B 21.1A B 08 32,33,34,35 ET272,ET273,ET274,ET275
ETC 0 B 21.1J B 09 36,37,38,39 ET276,ET277,ET278,ET279
ETC 0 B 21.1R B 10 40,41,42,43 ET280,ET281,ET282,ET283
ETC 0 B 21.1Z B 11 44,45,46,47 ET284,ET285,ET286,ET287
Table 6 Balanced panel at the BSCC cabinet top in first deliveries
ETC car-tridge
From GT6C-A connector position
To CPETS-G connector position
Front ports in CPETS-G panel through this cable
Corresponding external ET numbers
ETC 0 B 01.1A B 00 00,01,02,03 ET512,ET513,ET514,ET515
ETC 0 B 01.1J B 01 04,05,06,07 ET516,ET517,ET518,ET519
ETC 0 B 01.1R B 02 08,09,10,11 ET520,ET521,ET522,ET523
ETC 0 B 01.1Z B 03 12,13,14,15 ET524,ET525,ET526,ET527
ETC 0 B 02.1A B 04 16,17,18,19 ET528,ET529,ET530,ET531
ETC 0 B 02.1J B 05 20,21,22,23 ET532,ET533,ET534,ET535
ETC 0 B 02.1R B 06 24,25,26,27 ET536,ET537,ET538,ET539
ETC 0 B 02.1Z B 07 28,29,30,31 ET540,ET541,ET542,ET543
ETC 0 B 03.1A B 08 32,33,34,35 ET544,ET545,ET546,ET547
ETC 0 B 03.1J B 09 36,37,38,39 ET548,ET549,ET550,ET551
ETC 0 B 03.1R B 10 40,41,42,43 ET552,ET553,ET554,ET555
ETC 0 B 03.1Z B 11 44,45,46,47 ET556,ET557,ET558,ET559
Table 7 Balanced panel at the BSCC cabinet top in upgrade deliveries
DN70617303Issue 1-0
19
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1 (PCM) balanced trunk cable panels (CPETS-G andCPETS-H)
Id:0900d805804d10f1
E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H)The following table shows the connector panels in the cabling cabinet.
The cables and the connectors should meet the requirements of the UL 1459 standard or the National Electrical Code ANSI/NFPA No.70. The connectors should also meet the requirements of the FCC Part 68.
Recommended cable type for E1 trunk cables (CNIB) is presented in the following table and figure.
Figure 4 RJ45 connector cable (CNIB cable type) with four connectors
Equipping orderThe equipping order of the connector panels in the cabling cabinet in first deliveries is presented in the following table.
Panel number
Connector panel
T00 CPETS-G
0 CPETS-H
1 CPETS-G
2 CPETS-G
3 CPETS-G
4 CPETS-H
Table 8 Balanced connector panels for the BSC3i
Cable type: 4x(4x2xAWG26/1) 120 Ω , insulated pairs, twisted, double-shielded, cross section 0.4 mm2
Cable connector: RJ45 modular connector plug (8-pole)
Table 9 Recommended cable type for E1 trunk cables (CNIB)
CONNECTOR
DN00206525
1 2 3 4
20 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804d10f1
E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H)
ETC/GTIC index
From SGC1C-A connector position
To panel / connector position
Front ports in balanced panel through this cable
Corresponding external ET numbers
ETC 0 B 22.1A Panel 00 / B 00 00,01,02,03 ET256,ET257,ET258,ET259
ETC 0 B 22.1J Panel 00 / B 01 04,05,06,07 ET260,ET261,ET262,ET263
ETC 0 B 22.1R Panel 00 / B 02 08,09,10,11 ET264,ET265,ET266,ET267
ETC 0 B 22.1Z Panel 00 / B 03 12,13,14,15 ET268,ET269,ET270,ET271
ETC 0 B 23.1A Panel 00 / B 04 16,17,18,19 ET304,ET305,ET306,ET307
ETC 0 B 23.1J Panel 00 / B 05 20,21,22,23 ET308,ET309,ET310,ET311
ETC 0 B 23.1R Panel 00 / B 06 24,25,26,27 ET312,ET313,ET314,ET315
ETC 0 B 23.1Z Panel 00 / B 07 28,29,30,31 ET316,ET317,ET318,ET319
ETC 0 B 24.1A Panel 00 / B 08 32,33,34,35 ET320,ET321,ET322,ET323
ETC 0 B 24.1J Panel 00 / B 09 36,37,38,39 ET324,ET325,ET326,ET327
ETC 0 B 24.1R Panel 00 / B 10 40,41,42,43 ET328,ET329,ET330,ET331
ETC 0 B 24.1Z Panel 00 / B 11 44,45,46,47 ET332,ET333,ET334,ET335
ETC 0 B 25.1A Panel 00 / B 12 48,49,50,51 ET336,ET337,ET338,ET339
ETC 0 B 25.1J Panel 00 / B 13 52,53,54,55 ET340,ET341,ET342,ET343
ETC 0 B 25.1R Panel 00 / B 14 56,57,58,59 ET344,ET345,ET346,ET347
ETC 0 B 25.1Z Panel 00 / B 15 60,61,62,63 ET348,ET349,ET350,ET351
ETC 0 B 26.1A Panel 00 / B 16 64,65,66,67 ET352,ET353,ET354,ET355
ETC 0 B 26.1J Panel 00 / B 17 68,69,70,71 ET356,ET357,ET358,ET359
ETC 0 B 26.1R Panel 00 / B 18 72,73,74,75 ET360,ET361,ET362,ET363
ETC 0 B 26.1Z Panel 00 / B 19 76,77,78,79 ET364,ET365,ET366,ET367
ETC 1 B 28.1A Panel 00 / B 20 80,81,82,83 ET640,ET641,ET642,ET643
ETC 1 B 28.1J Panel 00 / B 21 84,85,86,87 ET644,ET645,ET646,ET647
ETC 1 B 28.1R Panel 00 / B 22 88,89,90,91 ET648,ET649,ET650,ET651
ETC 1 B 28.1Z Panel 00 / B 23 92,93,94,95 ET652,ET653,ET654,ET655
ETC 1 B 29.1A Panel 00 / B 24 96,97,98,99 ET624,ET625,ET626,ET627
ETC 1 B 29.1J Panel 00 / B 25 100,101,102,103 ET628,ET629,ET630,ET631
ETC 1 B 29.1R Panel 00 / B 26 104,105,106,107 ET632,ET633,ET634,ET635
ETC 1 B 29.1Z Panel 00 / B 27 108,109,110,111 ET636,ET637,ET638,ET639
ETC 1 B 30.1A Panel 00 / B 28 112,113,114,115 ET512,ET513,ET514,ET515
ETC 1 B 30.1J Panel 00 / B 29 116,117,118,119 ET516,ET517,ET518,ET519
ETC 1 B 30.1R Panel 00 / B 30 120,121,122,123 ET520,ET521,ET522,ET523
ETC 1 B 30.1Z Panel 00 / B 31 124,125,126,127 ET524,ET525,ET526,ET527
ETC 1 B 31.1A Panel 00 / B 32 128,129,130,131 ET528,ET529,ET530,ET531
Table 10 Balanced panels in first deliveries
DN70617303Issue 1-0
21
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1 (PCM) balanced trunk cable panels (CPETS-G andCPETS-H)
Id:0900d805804d10f1
ETC 1 B 31.1J Panel 00 / B 33 132,133,134,135 ET532,ET533,ET534,ET535
ETC 1 B 31.1R Panel 00 / B 34 136,137,138,139 ET536,ET537,ET538,ET539
ETC 1 B 31.1Z Panel 00 / B 35 140,141,142,143 ET540,ET541,ET542,ET543
ETC 1 B 32.1A Panel 00 / B 36 144,145,146,147 ET544,ET545,ET546,ET547
ETC 1 B 32.1J Panel 00 / B 37 148,149,150,151 ET548,ET549,ET550,ET551
ETC 1 B 32.1R Panel 00 / B 38 152,153,154,155 ET552,ET553,ET554,ET555
ETC 1 B 32.1Z Panel 00 / B 39 156,157,158,159 ET556,ET557,ET558,ET559
ETC 1 B 33.1A Panel 00 / B 40 160,161,162,163 ET560,ET561,ET562,ET563
ETC 1 B 33.1J Panel 00 / B 41 164,165,166,167 ET564,ET565,ET566,ET567
ETC 1 B 33.1R Panel 00 / B 42 168,169,170,171 ET568,ET569,ET570,ET571
ETC 1 B 33.1Z Panel 00 / B 43 172,173,174,175 ET572,ET573,ET574,ET575
ETC 1 B 34.1A Panel 00 / B 44 176,177,178,179 ET576,ET577,ET578,ET579
ETC 1 B 34.1J Panel 00 / B 45 180,181,182,183 ET580,ET581,ET582,ET583
ETC 1 B 34.1R Panel 00 / B 46 184,185,186,187 ET584,ET585,ET586,ET587
ETC 1 B 34.1Z Panel 00 / B 47 188,189,190,191 ET588,ET589,ET590,ET591
ETC 1 B 35.1A Panel 00 / B 48 192,193,194,195 ET592,ET593,ET594,ET595
ETC 1 B 35.1J Panel 00 / B 49 196,197,198,199 ET596,ET597,ET598,ET599
ETC 1 B 35.1R Panel 00 / B 50 200,201,202,203 ET600,ET601,ET602,ET603
ETC 1 B 35.1Z Panel 00 / B 51 204,205,206,207 ET604,ET605,ET606,ET607
ETC 1 B 36.1A Panel 00 / B 52 208,209,210,211 ET608,ET609,ET610,ET611
ETC 1 B 36.1J Panel 00 / B 53 212,213,214,215 ET612,ET613,ET614,ET615
ETC 1 B 36.1R Panel 00 / B 54 216,217,218,219 ET616,ET617,ET618,ET619
ETC 1 B 36.1Z Panel 00 / B 55 220,221,222,223 ET620,ET621,ET622,ET623
GTIC 0 B 10.1A Panel 00 / B 56 224,225,226,227ET1392,ET1393,ET1394,ET1395
GTIC 0 B 10.1J Panel 00 / B 57 228,229,230,231ET1396,ET1397,ET1398,ET1399
GTIC 0 B 10.1R Panel 00 / B 58 232,233,234,235ET1400,ET1401,ET1402,ET1403
GTIC 0 B 10.1Z Panel 00 / B 59 236,237,238,239ET1404,ET1405,ET1406,ET1407
GTIC 0 B 11.1A Panel 00 / B 60 240,241,242,243ET1280,ET1281,ET1282,ET1283
GTIC 0 B 11.1J Panel 00 / B 61 244,245,246,247ET1284,ET1285,ET1286,ET1287
ETC/GTIC index
From SGC1C-A connector position
To panel / connector position
Front ports in balanced panel through this cable
Corresponding external ET numbers
Table 10 Balanced panels in first deliveries (Cont.)
22 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804d10f1
E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H)
GTIC 0 B 11.1R Panel 00 / B 62 248,249,250,251ET1288,ET1289,ET1290,ET1291
GTIC 0 B 11.1Z Panel 00 / B 63 252,253,254,255ET1292,ET1293,ET1294,ET1295
GTIC 1 B 10.1A Panel 01 / B 00 00,01,02,03ET1920,ET1921,ET1922,ET1923
GTIC 1 B 10.1J Panel 01 / B 01 04,05,06,07ET1924,ET1925,ET1926,ET1927
GTIC 1 B 10.1R Panel 01 / B 02 08,09,10,11ET1928,ET1929,ET1930,ET1931
GTIC 1 B 10.1Z Panel 01 / B 03 12,13,14,15ET1932,ET1933,ET1934,ET1935
GTIC 1 B 11.1A Panel 01 / B 04 16,17,18,19ET1936,ET1937,ET1938,ET1939
GTIC 1 B 11.1J Panel 01 / B 05 20,21,22,23ET1940,ET1941,ET1942,ET1943
GTIC 1 B 11.1R Panel 01 / B 06 24,25,26,27ET1944,ET1945,ET1946,ET1947
GTIC 1 B 11.1Z Panel 01 / B 07 28,29,30,31ET1948,ET1949,ET1950,ET1951
GTIC 1 B 12.1A Panel 01 / B 08 32,33,34,35ET1952,ET1953,ET1954,ET1955
GTIC 1 B 12.1J Panel 01 / B 09 36,37,38,39ET1956,ET1957,ET1958,ET1959
GTIC 1 B 12.1R Panel 01 / B 10 40,41,42,43ET1960,ET1961,ET1962,ET1963
GTIC 1 B 12.1Z Panel 01 / B 11 44,45,46,47ET1964,ET1965,ET1966,ET1967
GTIC 1 B 13.1A Panel 02 / B 00 00,01,02,03ET1968,ET1969,ET1970,ET1971
GTIC 1 B 13.1J Panel 02 / B 01 04,05,06,07ET1972,ET1973,ET1974,ET1975
GTIC 1 B 13.1R Panel 02 / B 02 08,09,10,11ET1976,ET1977,ET1978,ET1979
GTIC 1 B 13.1Z Panel 02 / B 03 12,13,14,15ET1980,ET1981,ET1982,ET1983
GTIC 1 B 14.1A Panel 02 / B 04 16,17,18,19ET1984,ET1985,ET1986,ET1987
GTIC 1 B 14.1J Panel 02 / B 05 20,21,22,23ET1988,ET1989,ET1990,ET1991
ETC/GTIC index
From SGC1C-A connector position
To panel / connector position
Front ports in balanced panel through this cable
Corresponding external ET numbers
Table 10 Balanced panels in first deliveries (Cont.)
DN70617303Issue 1-0
23
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1 (PCM) balanced trunk cable panels (CPETS-G andCPETS-H)
Id:0900d805804d10f1
GTIC 1 B 14.1R Panel 02 / B 06 24,25,26,27ET1992,ET1993,ET1994,ET1995
GTIC 1 B 14.1Z Panel 02 / B 07 28,29,30,31ET1996,ET1997,ET1998,ET1999
GTIC 1 B 15.1A Panel 02 / B 08 32,33,34,35ET2000,ET2001,ET2002,ET2003
GTIC 1 B 15.1J Panel 02 / B 09 36,37,38,39ET2004,ET2005,ET2006,ET2007
GTIC 1 B 15.1R Panel 02 / B 10 40,41,42,43ET2008,ET2009,ET2010,ET2011
GTIC 1 B 15.1Z Panel 02 / B 11 44,45,46,47ET2012,ET2013,ET2014,ET2015
GTIC 1 B 16.1A Panel 03 / B 00 00,01,02,03ET2016,ET2017,ET2018,ET2019
GTIC 1 B 16.1J Panel 03 / B 01 04,05,06,07ET2020,ET2021,ET2022,ET2023
GTIC 1 B 16.1R Panel 03 / B 02 08,09,10,11ET2024,ET2025,ET2026,ET2027
GTIC 1 B 16.1Z Panel 03 / B 03 12,13,14,15ET2028,ET2029,ET2030,ET2031
GTIC 1 B 17.1A Panel 03 / B 04 16,17,18,19ET2032,ET2033,ET2034,ET2035
GTIC 1 B 17.1J Panel 03 / B 05 20,21,22,23ET2036,ET2037,ET2038,ET2039
GTIC 1 B 17.1R Panel 03 / B 06 24,25,26,27ET2040,ET2041,ET2042,ET2043
GTIC 1 B 17.1Z Panel 03 / B 07 28,29,30,31ET2044,ET2045,ET2046,ET2047
ETC 2 B 19.1A Panel 03 / B 08 32,33,34,35ET1136,ET1137,ET1138,ET1139
ETC 2 B 19.1J Panel 03 / B 09 36,37,38,39ET1140,ET1141,ET1142,ET1143
ETC 2 B 19.1R Panel 03 / B 10 40,41,42,43ET1140,ET1141,ET1142,ET1143
ETC 2 B 19.1Z Panel 03 / B 11 44,45,46,47ET1140,ET1141,ET1142,ET1143
ETC 2 B 20.1A Panel 04 / B 00 00,01,02,03ET1024,ET1025,ET1026,ET1027
ETC/GTIC index
From SGC1C-A connector position
To panel / connector position
Front ports in balanced panel through this cable
Corresponding external ET numbers
Table 10 Balanced panels in first deliveries (Cont.)
24 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804d10f1
E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H)
ETC 2 B 20.1J Panel 04 / B 01 04,05,06,07ET1028,ET1029,ET1030,ET1031
ETC 2 B 20.1R Panel 04 / B 02 08,09,10,11ET1032,ET1033,ET1034,ET1035
ETC 2 B 20.1Z Panel 04 / B 03 12,13,14,15ET1036,ET1037,ET1038,ET1039
ETC 2 B 21.1A Panel 04 / B 04 16,17,18,19ET1040,ET1041,ET1042,ET1043
ETC 2 B 21.1J Panel 04 / B 05 20,21,22,23ET1044,ET1045,ET1046,ET1047
ETC 2 B 21.1R Panel 04 / B 06 24,25,26,27ET1048,ET1049,ET1050,ET1051
ETC 2 B 21.1Z Panel 04 / B 07 28,29,30,31ET1052,ET1053,ET1054,ET1055
ETC 2 B 22.1A Panel 04 / B 08 32,33,34,35ET1056,ET1057,ET1058,ET1059
ETC 2 B 22.1J Panel 04 / B 09 36,37,38,39ET1060,ET1061,ET1062,ET1063
ETC 2 B 22.1R Panel 04 / B 10 40,41,42,43ET1064,ET1065,ET1066,ET1067
ETC 2 B 22.1Z Panel 04 / B 11 44,45,46,47ET1068,ET1069,ET1070,ET1071
ETC 2 B 23.1A Panel 04 / B 12 48,49,50,51ET1072,ET1073,ET1074,ET1075
ETC 2 B 23.1J Panel 04 / B 13 52,53,54,55ET1076,ET1077,ET1078,ET1079
ETC 2 B 23.1R Panel 04 / B 14 56,57,58,59ET1080,ET1081,ET1082,ET1083
ETC 2 B 23.1Z Panel 04 / B 15 60,61,62,63ET1084,ET1085,ET1086,ET1087
ETC 2 B 24.1A Panel 04 / B 16 64,65,66,67ET1088,ET1089,ET1090,ET1091
ETC 2 B 24.1J Panel 04 / B 17 68,69,70,71ET1092,ET1093,ET1094,ET1095
ETC 2 B 24.1R Panel 04 / B 18 72,73,74,75ET1096,ET1097,ET1098,ET1099
ETC 2 B 24.1Z Panel 04 / B 19 76,77,78,79ET1100,ET1101,ET1102,ET1103
ETC 2 B 25.1A Panel 04 / B 20 80,81,82,83ET1104,ET1105,ET1106,ET1107
ETC 2 B 25.1J Panel 04 / B 21 84,85,86,87ET1108,ET1109,ET1110,ET1111
ETC/GTIC index
From SGC1C-A connector position
To panel / connector position
Front ports in balanced panel through this cable
Corresponding external ET numbers
Table 10 Balanced panels in first deliveries (Cont.)
DN70617303Issue 1-0
25
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1 (PCM) balanced trunk cable panels (CPETS-G andCPETS-H)
Id:0900d805804d10f1
ETC 2 B 25.1R Panel 04 / B 22 88,89,90,91ET1112,ET1113,ET1114,ET1115
ETC 2 B 25.1Z Panel 04 / B 23 92,93,94,95ET1116,ET1117,ET1118,ET1119
ETC 2 B 26.1A Panel 04 / B 24 96,97,98,99ET1120,ET1121,ET1122,ET1123
ETC 2 B 26.1J Panel 04 / B 25 100,101,102,103ET1124,ET1125,ET1126,ET1127
ETC 2 B 26.1R Panel 04 / B 26 104,105,106,107ET1128,ET1129,ET1130,ET1131
ETC 2 B 26.1Z Panel 04 / B 27 108,109,110,111ET1132,ET1133,ET1134,ET1135
ETC 3 B 28.1A Panel 04 / B 28 112,113,114,115 ET896,ET897,ET898,ET899
ETC 3 B 28.1J Panel 04 / B 29 116,117,118,119 ET900,ET901,ET902,ET903
ETC 3 B 28.1R Panel 04 / B 30 120,121,122,123 ET904,ET905,ET906,ET907
ETC 3 B 28.1Z Panel 04 / B 31 124,125,126,127 ET908,ET909,ET910,ET911
ETC 3 B 29.1A Panel 04 / B 32 128,129,130,131 ET880,ET881,ET882,ET883
ETC 3 B 29.1J Panel 04 / B 33 132,133,134,135 ET884,ET885,ET886,ET887
ETC 3 B 29.1R Panel 04 / B 34 136,137,138,139 ET888,ET889,ET890,ET891
ETC 3 B 29.1Z Panel 04 / B 35 140,141,142,143 ET892,ET893,ET894,ET895
ETC 3 B 30.1A Panel 04 / B 36 144,145,146,147 ET768,ET769,ET770,ET771
ETC 3 B 30.1J Panel 04 / B 37 148,149,150,151 ET772,ET773,ET774,ET775
ETC 3 B 30.1R Panel 04 / B 38 152,153,154,155 ET776,ET777,ET778,ET779
ETC 3 B 30.1Z Panel 04 / B 39 156,157,158,159 ET780,ET781,ET782,ET783
ETC 3 B 31.1A Panel 04 / B 40 160,161,162,163 ET784,ET785,ET786,ET787
ETC 3 B 31.1J Panel 04 / B 41 164,165,166,167 ET788,ET789,ET790,ET791
ETC 3 B 31.1R Panel 04 / B 42 168,169,170,171 ET792,ET793,ET794,ET795
ETC 3 B 31.1Z Panel 04 / B 43 172,173,174,175 ET796,ET797,ET798,ET799
ETC 3 B 32.1A Panel 04 / B 44 176,177,178,179 ET800,ET801,ET802,ET803
ETC 3 B 32.1J Panel 04 / B 45 180,181,182,183 ET804,ET805,ET806,ET807
ETC 3 B 32.1R Panel 04 / B 46 184,185,186,187 ET808,ET809,ET810,ET811
ETC 3 B 32.1Z Panel 04 / B 47 188,189,190,191 ET812,ET813,ET814,ET815
ETC 3 B 33.1A Panel 04 / B 48 192,193,194,195 ET816,ET817,ET818,ET819
ETC 3 B 33.1J Panel 04 / B 49 196,197,198,199 ET820,ET821,ET822,ET823
ETC 3 B 33.1R Panel 04 / B 50 200,201,202,203 ET824,ET825,ET826,ET827
ETC 3 B 33.1Z Panel 04 / B 51 204,205,206,207 ET828,ET829,ET830,ET831
ETC/GTIC index
From SGC1C-A connector position
To panel / connector position
Front ports in balanced panel through this cable
Corresponding external ET numbers
Table 10 Balanced panels in first deliveries (Cont.)
26 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804d10f1
E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H)
The equipping order of the connector panels in the cabling cabinet in upgrade deliveries is presented in the following table.
ETC 3 B 34.1A Panel 04 / B 52 208,209,210,211 ET832,ET833,ET834,ET835
ETC 3 B 34.1J Panel 04 / B 53 212,213,214,215 ET836,ET837,ET838,ET839
ETC 3 B 34.1R Panel 04 / B 54 216,217,218,219 ET840,ET841,ET842,ET843
ETC 3 B 34.1Z Panel 04 / B 55 220,221,222,223 ET844,ET845,ET846,ET847
ETC 3 B 35.1A Panel 04 / B 56 224,225,226,227 ET848,ET849,ET850,ET851
ETC 3 B 35.1J Panel 04 / B 57 228,229,230,231 ET852,ET853,ET854,ET855
ETC 3 B 35.1R Panel 04 / B 58 232,233,234,235 ET856,ET857,ET858,ET859
ETC 3 B 35.1Z Panel 04 / B 59 236,237,238,239 ET860,ET861,ET862,ET863
ETC 3 B 36.1A Panel 04 / B 60 240,241,242,243 ET864,ET865,ET866,ET867
ETC 3 B 36.1J Panel 04 / B 61 244,245,246,247 ET868,ET869,ET870,ET871
ETC 3 B 36.1R Panel 04 / B 62 248,249,250,251 ET872,ET873,ET874,ET875
ETC 3 B 36.1Z Panel 04 / B 63 252,253,254,255 ET876,ET877,ET878,ET879
GTIC 0 B 12.1A Panel T00 / B 00 00,01,02,03ET1296,ET1297,ET1298,ET1299
GTIC 0 B 12.1J Panel T00 / B 01 04,05,06,07ET1300,ET1301,ET1302,ET1303
GTIC 0 B 12.1R Panel T00 / B 02 08,09,10,11ET1304,ET1305,ET1306,ET1307
GTIC 0 B 12.1Z Panel T00 / B 03 12,13,14,15ET1308,ET1309,ET1310,ET1311
GTIC 0 B 13.1A Panel T00 / B 04 16,17,18,19ET1312,ET1313,ET1314,ET1315
GTIC 0 B 13.1J Panel T00 / B 05 20,21,22,23ET1316,ET1317,ET1318,ET1319
GTIC 0 B 13.1R Panel T00 / B 06 24,25,26,27ET1320,ET1321,ET1322,ET1323
GTIC 0 B 13.1Z Panel T00 / B 07 28,29,30,31ET1324,ET1325,ET1326,ET1327
GTIC 0 B 14.1A Panel T00 / B 08 32,33,34,35ET1328,ET1329,ET1330,ET1331
GTIC 0 B 14.1J Panel T00 / B 09 36,37,38,39ET1332,ET1333,ET1334,ET1335
GTIC 0 B 14.1R Panel T00 / B 10 40,41,42,43ET1336,ET1337,ET1338,ET1339
GTIC 0 B 14.1Z Panel T00 / B 11 44,45,46,47ET1340,ET1341,ET1342,ET1343
ETC/GTIC index
From SGC1C-A connector position
To panel / connector position
Front ports in balanced panel through this cable
Corresponding external ET numbers
Table 10 Balanced panels in first deliveries (Cont.)
DN70617303Issue 1-0
27
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1 (PCM) balanced trunk cable panels (CPETS-G andCPETS-H)
Id:0900d805804d10f1
ETC/GTIC cartridge
From GT4C-A connector position
To panel / connector position
Front ports in balanced panel through this cable
Corresponding external ET numbers
ETC 0 B 04.1A Panel 04 / B 61 244,245,246,247 ET560,ET561,ET562,ET563
ETC 0 B 04.1J Panel 04 / B 62 248,249,250,251 ET564,ET565,ET566,ET567
ETC 0 B 04.1R Panel 04 / B 63 252,253,254,255 ET568,ET569,ET570,ET571
ETC 0 B 04.1Z Panel 04 / B 58 232,233,234,235 ET572,ET573,ET574,ET575
ETC 1 B 01.1A Panel 04 / B 59 236,237,238,239 ET576,ET577,ET578,ET579
ETC 1 B 01.1J Panel 04 / B 60 240,241,242,243 ET580,ET581,ET582,ET583
ETC 1 B 01.1R Panel 04 / B 55 220,221,222,223 ET584,ET585,ET586,ET587
ETC 1 B 01.1Z Panel 04 / B 56 224,225,226,227 ET588,ET589,ET590,ET591
ETC 1 B 02.1A Panel 04 / B 57 228,229,230,231 ET592,ET593,ET594,ET595
ETC 1 B 02.1J Panel 04 / B 52 208,209,210,211 ET596,ET597,ET598,ET599
ETC 1 B 02.1R Panel 04 / B 53 212,213,214,215 ET600,ET601,ET602,ET603
ETC 1 B 02.1Z Panel 04 / B 54 216,217,218,219 ET604,ET605,ET606,ET607
ETC 1 B 03.1A Panel 04 / B 49 196,197,198,199 ET608,ET609,ET610,ET611
ETC 1 B 03.1J Panel 04 / B 50 200,201,202,203 ET612,ET613,ET614,ET615
ETC 1 B 03.1R Panel 04 / B 51 204,205,206,207 ET616,ET617,ET618,ET619
ETC 1 B 03.1Z Panel 04 / B 47 188,189,190,191 ET620,ET621,ET622,ET623
ETC 1 B 04.1A Panel 04 / B 48 192,193,194,195 ET624,ET625,ET626,ET627
ETC 1 B 04.1J Panel 04 / B 44 176,177,178,179 ET628,ET629,ET630,ET631
ETC 1 B 04.1R Panel 04 / B 45 180,181,182,183 ET632,ET633,ET634,ET635
ETC 1 B 04.1Z Panel 04 / B 46 184,185,186,187 ET636,ET637,ET638,ET639
GTIC 0 / ETC 5
B 01.1A (GTIC 0) / B03.1A (ETC 5) Panel 04 / B 41 164,165,166,167 ET904,ET905,ET906,ET907
GTIC 0 / ETC 5
B 01.1J (GTIC 0) / B03.1J (ETC 5) Panel 04 / B 42 168,169,170,171 ET908,ET909,ET910,ET911
GTIC 0 / ETC 5
B 01.1R (GTIC 0) / B03.1R (ETC 5) Panel 04 / B 43 172,173,174,175 ET912,ET913,ET914,ET915
GTIC 0 / ETC 5
B 01.1Z (GTIC 0) / B03.1Z (ETC 5) Panel 04 / B 38 152,153,154,155 ET916,ET917,ET918,ET919
GTIC 0 / ETC 5
B 02.1A (GTIC 0) / B04.1A (ETC 5) Panel 04 / B 39 156,157,158,159 ET920,ET921,ET922,ET923
GTIC 0 / ETC 5
B 02.1J (GTIC 0) / B04.1J (ETC 5) Panel 04 / B 40 160,161,162,163 ET924,ET925,ET926,ET927
GTIC 0 / ETC 5
B 02.1R (GTIC 0) / B04.1R (ETC 5) Panel 04 / B 35 140,141,142,143 ET928,ET929,ET930,ET931
GTIC 0 / ETC 5
B 02.1Z (GTIC 0) / B04.1Z (ETC 5) Panel 04 / B 36 144,145,146,147 ET932,ET933,ET934,ET935
Table 11 Balanced panels in upgrade deliveries
28 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804d10f1
E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H)
GTIC 0 / ETC 5
B 03.1A (GTIC 0) / B05.1A (ETC 5) Panel 04 / B 37 148,149,150,151 ET936,ET937,ET938,ET939
GTIC 0 / ETC 5
B 03.1J (GTIC 0) / B05.1J (ETC 5) Panel 04 / B 32 128,129,130,131 ET940,ET941,ET942,ET943
GTIC 0 / ETC 5
B 03.1R (GTIC 0) / B05.1R (ETC 5) Panel 04 / B 33 132,133,134,135 ET944,ET945,ET946,ET947
GTIC 0 / ETC 5
B 03.1Z (GTIC 0) / B05.1Z (ETC 5) Panel 04 / B 34 136,137,138,139 ET948,ET949,ET950,ET951
GTIC 0 / ETC 5
B 04.1A (GTIC 0) / B06.1A (ETC 5) Panel 04 / B 29 116,117,118,119 ET816,ET817,ET818,ET819
GTIC 0 / ETC 5
B 04.1J (GTIC 0) / B06.1J (ETC 5) Panel 04 / B 30 120,121,122,123 ET820,ET821,ET822,ET823
GTIC 0 / ETC 5
B 04.1R (GTIC 0) / B06.1R (ETC 5) Panel 04 / B 31 124,125,126,127 ET824,ET825,ET826,ET827
GTIC 0 / ETC 5
B 04.1Z (GTIC 0) / B06.1Z (ETC 5) Panel 04 / B 26 104,105,106,107 ET828,ET829,ER830,ET831
GTIC 0 / ETC 5
B 05.1A (GTIC 0) / B07.1A (ETC 5) Panel 04 / B 27 108,109,110,111
ET1072,ET1073,ET1074,ET1075
GTIC 0 / ETC 5
B 05.1J (GTIC 0) / B07.1J (ETC 5) Panel 04 / B 28 112,113,114,115
ET1076,ET1077,ET1078,ET1079
GTIC 0 / ETC 5
B 05.1R (GTIC 0) / B07.1R (ETC 5) Panel 04 / B 23 92,93,94,95
ET1080,ET1081,ET1082,ET1083
GTIC 0 / ETC 5
B 05.1Z (GTIC 0) / B07.1Z (ETC 5) Panel 04 / B 24 96,97,98,99
ET1084,ET1085,ET1086,ET1087
GTIC 0 / ETC 5
B 06.1A (GTIC 0) / B08.1A (ETC 5) Panel 04 / B 25 100,101,102,103
ET1328,ET1329,ET1330,ET1331
GTIC 0 / ETC 5
B 06.1J (GTIC 0) / B08.1J (ETC 5) Panel 04 / B 20 80,81,82,83
ET1332,ET1333,ET1334,ET1335
GTIC 0 / ETC 5
B 06.1R (GTIC 0) / B08.1R (ETC 5) Panel 04 / B 21 84,85,86,87
ET1336,ET1337,ET1338,ET1339
GTIC 0 / ETC 5
B 06.1Z (GTIC 0) / B08.1Z (ETC 5) Panel 04 / B 22 88,89,90,91
ET1340,ET1341,ET1342,ET1343
GTIC 0 B 07.1A Panel 04 / B 17 68,69,70,71ET1792,ET1793,ET1794,ET1795
GTIC 0 B 07.1J Panel 04 / B 18 72,73,74,75ET1796,ET1797,ET1798,ET1799
GTIC 0 B 07.1R Panel 04 / B 19 76,77,78,79ET1800,ET1801,ET1802,ET1803
GTIC 0 B 07.1Z Panel 04 / B 15 60,61,62,63ET1804,ET1805,ET1806,ET1807
GTIC 0 B 08.1A Panel 04 / B 16 64,65,66,67ET1808,ET1809,ET1810,ET1811
ETC/GTIC cartridge
From GT4C-A connector position
To panel / connector position
Front ports in balanced panel through this cable
Corresponding external ET numbers
Table 11 Balanced panels in upgrade deliveries (Cont.)
DN70617303Issue 1-0
29
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1 (PCM) balanced trunk cable panels (CPETS-G andCPETS-H)
Id:0900d805804d10f1
GTIC 0 B 08.1J Panel 04 / B 12 48,49,50,51ET1812,ET1813,ET1814,ET1815
GTIC 0 B 08.1R Panel 04 / B 13 52,53,54,55ET1816,ET1817,ET1818,ET1819
GTIC 0 B 08.1Z Panel 04 / B 14 56,57,58,59ET1820,ET1821,ET1822,ET1823
GTIC 1 B 01.1A Panel 04 / B 09 36,37,38,39ET1408,ET1409,ET1410,ET1411
GTIC 1 B 01.1J Panel 04 / B 10 40,41,42,43ET1412,ET1413,ET1414,ET1415
GTIC 1 B 01.1R Panel 04 / B 11 44,45,46,47ET1416,ET1417,ET1418,ET1419
GTIC 1 B 01.1Z Panel 04 / B 06 24,25,26,27ET1420,ET1421,ET1422,ET1423
GTIC 1 B 02.1A Panel 04 / B 07 28,29,30,31ET1424,ET1425,ET1426,ET1427
GTIC 1 B 02.1J Panel 04 / B 08 32,33,34,35ET1428,ET1429,ET1430,ET1431
GTIC 1 B 02.1R Panel 04 / B 03 12,13,14,15ET1432,ET1433,ET1434,ET1435
GTIC 1 B 02.1Z Panel 04 / B 04 16,17,18,19ET1436,ET1437,ET1438,ET1439
GTIC 1 B 03.1A Panel 04 / B 05 20,21,22,23ET1440,ET1441,ET1442,ET1443
GTIC 1 B 03.1J Panel 04 / B 00 00,01,02,03ET1444,ET1445,ET1446,ET1447
GTIC 1 B 03.1R Panel 04 / B 01 04,05,06,07ET1448,ET1449,ET1450,ET1451
GTIC 1 B 03.1Z Panel 04 / B 02 08,09,10,11ET1452,ET1453,ET1454,ET1455
GTIC 1 B 04.1A Panel 03 / B 09 36,37,38,39ET1456,ET1457,ET1458,ET1459
GTIC 1 B 04.1J Panel 03 / B 10 40,41,42,43ET1460,ET1461,ET1462,ET1463
GTIC 1 B 04.1R Panel 03 / B 11 44,45,46,47ET1464,ET1465,ET1466,ET1467
GTIC 1 B 04.1Z Panel 03 / B 06 24,25,26,27ET1468,ET1469,ET1470,ET1471
GTIC 1 B 05.1A Panel 03 / B 07 28,29,30,31ET1472,ET1473,ET1474,ET1475
ETC/GTIC cartridge
From GT4C-A connector position
To panel / connector position
Front ports in balanced panel through this cable
Corresponding external ET numbers
Table 11 Balanced panels in upgrade deliveries (Cont.)
30 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804d10f1
E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H)
GTIC 1 B 05.1J Panel 03 / B 08 32,33,34,35ET1476,ET1477,ET1478,ET1479
GTIC 1 B 05.1R Panel 03 / B 03 12,13,14,15ET1480,ET1481,ET1482,ET1483
GTIC 1 B 05.1Z Panel 03 / B 04 16,17,18,19ET1484,ET1485,ET1486,ET1487
GTIC 1 B 06.1A Panel 03 / B 05 20,21,22,23ET1488,ET1489,ET1490,ET1491
GTIC 1 B 06.1J Panel 03 / B 00 00,01,02,03ET1492,ET1493,ET1494,ET1495
GTIC 1 B 06.1R Panel 03 / B 01 04,05,06,07ET1496,ET1497,ET1498,ET1499
GTIC 1 B 06.1Z Panel 03 / B 02 08,09,10,11ET1500,ET1501,ET1502,ET1503
GTIC 1 B 07.1A Panel 02 / B 09 36,37,38,39ET1504,ET1505,ET1506,ET1507
GTIC 1 B 07.1J Panel 02 / B 10 40,41,42,43ET1508,ET1509,ET1510,ET1511
GTIC 1 B 07.1R Panel 02 / B 11 44,45,46,47ET1512,ET1513,ET1514,ET1515
GTIC 1 B 07.1Z Panel 02 / B 06 24,25,26,27ET1516,ET1517,ET1518,ET1519
GTIC 1 B 08.1A Panel 02 / B 07 28,29,30,31ET1520,ET1521,ET1522,ET1523
GTIC 1 B 08.1J Panel 02 / B 08 32,33,34,35ET1524,ET1525,ET1526,ET1527
GTIC 1 B 08.1R Panel 02 / B 03 12,13,14,15ET1528,ET1529,ET1530,ET1531
GTIC 1 B 08.1Z Panel 02 / B 04 16,17,18,19ET1532,ET1533,ET1534,ET1535
ETC 2 B 01.1A Panel 02 / B 05 20,21,22,23ET1344,ET1345,ET1346,ET1347
ETC 2 B 01.1J Panel 02 / B 00 00,01,02,03ET1348,ET1349,ET1350,ET1351
ETC 2 B 01.1R Panel 02 / B 01 04,05,06,07ET1352,ET1353,ET1354,ET1355
ETC 2 B 01.1Z Panel 02 / B 02 08,09,10,11ET1356,ET1357,ET1358,ET1359
ETC 2 B 02.1A Panel 01 / B 09 36,37,38,39ET1360,ET1361,ET1362,ET1363
ETC/GTIC cartridge
From GT4C-A connector position
To panel / connector position
Front ports in balanced panel through this cable
Corresponding external ET numbers
Table 11 Balanced panels in upgrade deliveries (Cont.)
DN70617303Issue 1-0
31
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1 (PCM) balanced trunk cable panels (CPETS-G andCPETS-H)
Id:0900d805804d10f1
ETC 2 B 02.1J Panel 01 / B 10 40,41,42,43ET1364,ET1365,ET1366,ET1367
ETC 2 B 02.1R Panel 01 / B 11 44,45,46,47ET1368,ET1369,ET1370,ET1371
ETC 2 B 02.1Z Panel 01 / B 06 24,25,26,27ET1372,ET1373,ET1374,ET1375
ETC 2 B 03.1A Panel 01 / B 07 28,29,30,31ET1376,ET1377,ET1378,ET1379
ETC 2 B 03.1J Panel 01 / B 08 32,33,34,35ET1380,ET1381,ET1382,ET1383
ETC 2 B 03.1R Panel 01 / B 03 12,13,14,15ET1384,ET1385,ET1386,ET1387
ETC 2 B 03.1Z Panel 01 / B 04 16,17,18,19ET1388,ET1389,ET1390,ET1391
ETC 2 B 04.1A Panel 01 / B 05 20,21,22,23ET1392,ET1393,ET1394,ET1395
ETC 2 B 04.1J Panel 01 / B 00 00,01,02,03ET1396,ET1397,ET1398,ET1399
ETC 2 B 04.1R Panel 01 / B 01 04,05,06,07ET1400,ET1401,ET1402,ET1403
ETC 2 B 04.1Z Panel 01 / B 02 08,09,10,11ET1404,ET1405,ET1406,ET1407
ETC 2 B 05.1A Panel 00 / B 61 244,245,246,247ET1600,ET1601,ET1602,ET1603
ETC 2 B 05.1J Panel 00 / B 62 248,249,250,251ET1604,ET1605,ET1606,ET1607
ETC 2 B 05.1R Panel 00 / B 63 252,253,254,255ET1608,ET1609,ET1610,ET1611
ETC 2 B 05.1Z Panel 00 / B 58 232,233,234,235ET1612,ET1613,ET1614,ET1615
ETC 2 B 06.1A Panel 00 / B 59 236,237,238,239ET1616,ET1617,ET1618,ET1619
ETC 2 B 06.1J Panel 00 / B 60 240,241,242,243ET1620,ET1621,ET1622,ET1623
ETC 2 B 06.1R Panel 00 / B 55 220,221,222,223ET1624,ET1625,ET1626,ET1627
ETC 2 B 06.1Z Panel 00 / B 56 224,225,226,227ET1628,ET1629,ET1630,ET1631
ETC 2 B 07.1A Panel 00 / B 57 228,229,230,231ET1632,ET1633,ET1634,ET1635
ETC/GTIC cartridge
From GT4C-A connector position
To panel / connector position
Front ports in balanced panel through this cable
Corresponding external ET numbers
Table 11 Balanced panels in upgrade deliveries (Cont.)
32 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804d10f1
E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H)
ETC 2 B 07.1J Panel 00 / B 52 208,209,210,211ET1636,ET1637,ET1638,ET1639
ETC 2 B 07.1R Panel 00 / B 53 212,213,214,215ET1640,ET1641,ET1642,ET1643
ETC 2 B 07.1Z Panel 00 / B 54 216,217,218,219ET1644,ET1645,ET1646,ET1647
ETC 2 B 08.1A Panel 00 / B 49 196,197,198,199ET1648,ET1649,ET1650,ET1651
ETC 2 B 08.1J Panel 00 / B 50 200,201,202,203ET1652,ET1653,ET1654,ET1655
ETC 2 B 08.1R Panel 00 / B 51 204,205,206,207ET1656,ET1657,ET1658,ET1659
ETC 2 B 08.1Z Panel 00 / B 47 188,189,190,191ET1660,ET1661,ET1662,ET1663
ETC 3 B 01.1A Panel 00 / B 48 192,193,194,195ET1664,ET1665,ET1666,ET1667
ETC 3 B 01.1J Panel 00 / B 44 176,177,178,179ET1668,ET1669,ET1670,ET1671
ETC 3 B 01.1R Panel 00 / B 45 180,181,182,183ET1672,ET1673,ET1674,ET1675
ETC 3 B 01.1Z Panel 00 / B 46 184,185,186,187ET1676,ET1677,ET1678,ET1679
ETC 3 B 02.1A Panel 00 / B 41 164,165,166,167ET1680,ET1681,ET1682,ET1683
ETC 3 B 02.1J Panel 00 / B 42 168,169,170,171ET1684,ET1685,ET1686,ET1687
ETC 3 B 02.1R Panel 00 / B 43 172,173,174,175ET1688,ET1689,ET1690,ET1691
ETC 3 B 02.1Z Panel 00 / B 38 152,153,154,155ET1692,ET1693,ET1694,ET1695
ETC 3 B 03.1A Panel 00 / B 39 156,157,158,159ET1696,ET1697,ET1698,ET1699
ETC 3 B 03.1J Panel 00 / B 40 160,161,162,163ET1700,ET1701,ET1702,ET1703
ETC 3 B 03.1R Panel 00 / B 35 140,141,142,143ET1704,ET1705,ET1706,ET1707
ETC 3 B 03.1Z Panel 00 / B 36 144,145,146,147ET1708,ET1709,ET1710,ET1711
ETC 3 B 04.1A Panel 00 / B 37 148,149,150,151ET1712,ET1713,ET1714,ET1715
ETC 3 B 04.1J Panel 00 / B 32 128,129,130,131ET1716,ET1717,ET1718,ET1719
ETC/GTIC cartridge
From GT4C-A connector position
To panel / connector position
Front ports in balanced panel through this cable
Corresponding external ET numbers
Table 11 Balanced panels in upgrade deliveries (Cont.)
DN70617303Issue 1-0
33
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1 (PCM) balanced trunk cable panels (CPETS-G andCPETS-H)
Id:0900d805804d10f1
ETC 3 B 04.1R Panel 00 / B 33 132,133,134,135ET1720,ET1721,ET1722,ET1723
ETC 3 B 04.1Z Panel 00 / B 34 136,137,138,139ET1724,ET1725,ET1726,ET1727
ETC 3 B 05.1A Panel 00 / B 29 116,117,118,119ET1728,ET1729,ET1730,ET1731
ETC 3 B 05.1J Panel 00 / B 30 120,121,122,123ET1732,ET1733,ET1734,ET1735
ETC 3 B 05.1R Panel 00 / B 31 124,125,126,127ET1736,ET1737,ET1738,ET1739
ETC 3 B 05.1Z Panel 00 / B 26 104,105,106,107ET1740,ET1741,ET1742,ET1743
ETC 3 B 06.1A Panel 00 / B 27 108,109,110,111ET1744,ET1745,ET1746,ET1747
ETC 3 B 06.1J Panel 00 / B 28 112,113,114,115ET1748,ET1749,ET1750,ET1751
ETC 3 B 06.1R Panel 00 / B 23 92,93,94,95ET1752,ET1753,ET1754,ET1755
ETC 3 B 06.1Z Panel 00 / B 24 96,97,98,99ET1756,ET1757,ET1758,ET1759
ETC 3 B 07.1A Panel 00 / B 25 100,101,102,103ET1760,ET1761,ET1762,ET1763
ETC 3 B 07.1J Panel 00 / B 20 80,81,82,83ET1764,ET1765,ET1766,ET1767
ETC 3 B 07.1R Panel 00 / B 21 84,85,86,87ET1768,ET1769,ET1770,ET1771
ETC 3 B 07.1Z Panel 00 / B 22 88,89,90,91ET1772,ET1773,ET1774,ET1775
ETC 3 B 08.1A Panel 00 / B 17 68,69,70,71ET1776,ET1777,ET1778,ET1779
ETC 3 B 08.1J Panel 00 / B 18 72,73,74,75ET1780,ET1781,ET1782,ET1783
ETC 3 B 08.1R Panel 00 / B 19 76,77,78,79ET1784,ET1785,ET1786,ET1787
ETC 3 B 08.1Z Panel 00 / B 15 60,61,62,63ET1788,ET1789,ET1790,ET1791
ETC 4 B 01.1A Panel 00 / B 16 64,65,66,67ET1920,ET1921,ET1922,ET1923
ETC 4 B 01.1J Panel 00 / B 12 48,49,50,51ET1924,ET1925,ET1926,ET1927
ETC 4 B 01.1R Panel 00 / B 13 52,53,54,55ET1928,ET1929,ET1930,ET1931
ETC/GTIC cartridge
From GT4C-A connector position
To panel / connector position
Front ports in balanced panel through this cable
Corresponding external ET numbers
Table 11 Balanced panels in upgrade deliveries (Cont.)
34 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804d10f1
E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H)
3.3 TCSM3iTwo installation options of the third-generation Transcoder Submultiplexer are available: the TCSM3i for stand-alone installation option and the TCSM3i for combined BSC/TCSM installation option. The TCSM3i for stand-alone installation option always has a cabling cabinet, but the TCSM3i for combined BSC/TCSM installation option does not have a cabling cabinet.
3.3.1 TCSM3i for stand-alone installation optionIn the TCSM3i for stand-alone installation option, the cabling cabinet is always mounted to the TCSA cabinet.
E1 (PCM) balanced trunk cable panel (CPETS-H)Two large balanced CPETS-H connector panels are used in the cabling cabinet mounted to the TCSA cabinet.
ETC 4 B 01.1Z Panel 00 / B 14 56,57,58,59ET1932,ET1933,ET1934,ET1935
ETC 4 B 02.1A Panel 00 / B 09 36,37,38,39ET1936,ET1937,ET1938,ET1939
ETC 4 B 02.1J Panel 00 / B 10 40,41,42,43ET1940,ET1941,ET1942,ET1943
ETC 4 B 02.1R Panel 00 / B 11 44,45,46,47ET1944,ET1945,ET1946,ET1947
ETC 4 B 02.1Z Panel 00 / B 06 24,25,26,27ET1948,ET1949,ET1950,ET1951
ETC 4 B 03.1A Panel 00 / B 07 28,29,30,31ET1952,ET1953,ET1954,ET1955
ETC 4 B 03.1J Panel 00 / B 08 32,33,34,35ET1956,ET1957,ET1958,ET1959
ETC 4 B 03.1R Panel 00 / B 03 12,13,14,15ET1960,ET1961,ET1962,ET1963
ETC 4 B 03.1Z Panel 00 / B 04 16,17,18,19ET1964,ET1965,ET1966,ET1967
ETC 4 B 04.1A Panel 00 / B 05 20,21,22,23ET1968,ET1969,ET1970,ET1971
ETC 4 B 04.1J Panel 00 / B 00 00,01,02,03ET1972,ET1973,ET1974,ET1975
ETC 4 B 04.1R Panel 00 / B 01 04,05,06,07ET1976,ET1977,ET1978,ET1979
ETC 4 B 04.1Z Panel 00 / B 02 08,09,10,11ET1980,ET1981,ET1982,ET1983
ETC/GTIC cartridge
From GT4C-A connector position
To panel / connector position
Front ports in balanced panel through this cable
Corresponding external ET numbers
Table 11 Balanced panels in upgrade deliveries (Cont.)
DN70617303Issue 1-0
35
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1 (PCM) balanced trunk cable panels (CPETS-G andCPETS-H)
Id:0900d805804d10f1
The cables and connectors should meet the requirements of the UL 1459 standard or the National Electrical Code ANSI/NFPA No.70. The connectors should also meet the requirements of the FCC Part 68.
Recommended cable type for E1 trunk cables (CNIB) is presented in the following table and figure.
Figure 5 RJ45 connector cable (CNIB cable type) with four connectors
Equipping orderEquipping of ETs proceeds in steps. The equipping order in the cabling cabinet is pre-sented in the following table.
Panel number
Connector panel
0 CPETS-H
1 CPBP
2 CPBP
3 CPBP
4 CPETS-H
Table 12 Balanced connector panels for the TCSM3i
Cable type: 4x(4x2xAWG26/1) 120 Ω , insulated pairs, twisted, double-shielded, cross section 0.4 mm2
Cable connector: RJ45 modular connector plug (8-pole)
Table 13 Recommended cable type for E1 trunk cables (CNIB)
CONNECTOR
DN00206525
1 2 3 4
36 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804d10f1
E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H)
ETC car-tridge
From GT4C-A connector position
To panel / con-nector position
Front ports in CPETS-H panel
Front ports used for TR3 A-interface
ETC 0 B 01.1A Panel 0 / B 00 00, 01, 02, 03 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 01
ETC 0 B 01.1J Panel 0 / B 01 04, 05, 06, 07 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 02
ETC 0 B 01.1R Panel 0 / B 02 08, 09, 10, 11 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 03
ETC 0 B 01.1Z Panel 0 / B 03 12, 13, 14, 15 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 04
ETC 1 B 01.1A Panel 0 / B 04 16, 17, 18, 19 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 05
ETC 1 B 01.1J Panel 0 / B 05 20, 21, 22, 23 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 06
ETC 1 B 01.1R Panel 0 / B 06 24, 25, 26, 27 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 07
ETC 1 B 01.1Z Panel 0 / B 07 28, 29, 30, 31 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 08
ETC 2 B 01.1A Panel 0 / B 08 32, 33, 34, 35 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 09
ETC 2 B 01.1J Panel 0 / B 09 36, 37, 38, 39 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 10
ETC 2 B 01.1R Panel 0 / B 10 40, 41, 42, 43 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 11
ETC 2 B 01.1Z Panel 0 / B 11 44, 45, 46, 47 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 12
ETC 1 B 02.1A Panel 0 / B12 48, 49, 50, 51 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 13
ETC 1 B 02.1J Panel 0 / B13 52, 53, 54, 55 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 14
ETC 1 B 02.1R Panel 0 / B14 56, 57, 58, 59 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 15
ETC 1 B 02.1Z Panel 0 / B15 60, 61, 62, 63 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 16
ETC 0 B 02.1A Panel 0 / B16 64, 65, 66, 67 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 01
ETC 0 B 02.1J Panel 0 / B17 68, 69, 70, 71 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 02
ETC 0 B 02.1R Panel 0 / B18 72, 73, 74, 75 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 03
ETC 0 B 02.1Z Panel 0 / B19 76, 77, 78, 79 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 04
ETC 1 B 03.1A Panel 0 / B20 80, 81, 82, 83 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 05
ETC 1 B 03.1J Panel 0 / B21 84, 85, 86, 87 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 06
ETC 1 B 03.1R Panel 0 / B22 88, 89, 90, 91 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 07
ETC 1 B 03.1Z Panel 0 / B23 92, 93, 94, 95 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 08
ETC 2 B 02.1A Panel 0 / B24 96, 97, 98, 99 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 09
ETC 2 B 02.1J Panel 0 / B25 100, 101, 102, 103 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 10
ETC 2 B 02.1R Panel 0 / B26 104, 105, 106, 107 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 11
ETC 2 B 02.1Z Panel 0 / B27 108, 109, 110, 111 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 12
ETC 1 B 04.1A Panel 0 / B28 112, 113, 114, 115 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 13
ETC 1 B 04.1J Panel 0 / B29 116, 117, 118, 119 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 14
ETC 1 B 04.1R Panel 0 / B30 120, 121, 122, 123 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 15
ETC 1 B 04.1Z Panel 0 / B31 124, 125, 126, 127 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 16
ETC 0 B 03.1A Panel 0 / B32 128, 129, 130, 131 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 01
ETC 0 B 03.1J Panel 0 / B33 132, 133, 134, 135 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 02
Table 14 CPETS-H balanced panels in the TCSM3i cabling cabinet - A-interface
DN70617303Issue 1-0
37
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1 (PCM) balanced trunk cable panels (CPETS-G andCPETS-H)
Id:0900d805804d10f1
ETC 0 B 03.1R Panel 0 / B34 136, 137, 138, 139 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 03
ETC 0 B 03.1Z Panel 0 / B35 140, 141, 142, 143 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 04
ETC 1 B 05.1A Panel 0 / B36 144, 145, 146, 147 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 05
ETC 1 B 05.1J Panel 0 / B37 148, 149, 150, 151 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 06
ETC 1 B 05.1R Panel 0 / B38 152, 153, 154, 155 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 07
ETC 1 B 05.1Z Panel 0 / B39 156, 157, 158, 159 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 08
ETC 2 B 03.1A Panel 0 / B40 160, 161, 162, 163 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 09
ETC 2 B 03.1J Panel 0 / B41 164, 165, 166, 167 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 10
ETC 2 B 03.1R Panel 0 / B42 168, 169, 170, 171 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 11
ETC 2 B 03.1Z Panel 0 / B43 172, 173, 174, 175 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 12
ETC 1 B 06.1A Panel 0 / B44 176, 177, 178, 179 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 13
ETC 1 B 06.1J Panel 0 / B45 180, 181, 182, 183 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 14
ETC 1 B 06.1R Panel 0 / B46 184, 185, 186, 187 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 15
ETC 1 B 06.1Z Panel 0 / B47 188, 189, 190, 191 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 16
ETC 0 B 04.1A Panel 0 / B48 192, 193, 194, 195 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 01
ETC 0 B 04.1J Panel 0 / B49 196, 197, 198, 199 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 02
ETC 0 B 04.1R Panel 0 / B50 200, 201, 202, 203 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 03
ETC 0 B 04.1Z Panel 0 / B51 204, 205, 206, 207 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 04
ETC 1 B 07.1A Panel 0 / B52 208, 209, 210, 211 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 05
ETC 1 B 07.1J Panel 0 / B53 212, 213, 214, 215 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 06
ETC 1 B 07.1R Panel 0 / B54 216, 217, 218, 219 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 07
ETC 1 B 07.1Z Panel 0 / B55 220, 221, 222, 223 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 08
ETC 2 B 04.1A Panel 0 / B56 224, 225, 226, 227 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 09
ETC 2 B 04.1J Panel 0 / B57 228, 229, 230, 231 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 10
ETC 2 B 04.1R Panel 0 / B58 232, 233, 234, 235 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 11
ETC 2 B 04.1Z Panel 0 / B59 236, 237, 238, 239 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 12
ETC 1 B 08.1A Panel 0 / B60 240, 241, 242, 243 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 13
ETC 1 B 08.1J Panel 0 / B61 244, 245, 246, 247 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 14
ETC 1 B 08.1R Panel 0 / B62 248, 249, 250, 251 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 15
ETC 1 B 08.1Z Panel 0 / B63 252, 253, 254, 255 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 16
ETC 0 B 05.1A Panel 4 / B00 00, 01, 02, 03 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 01
ETC 0 B 05.1J Panel 4 / B01 04, 05, 06, 07 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 02
ETC 0 B 05.1R Panel 4 / B02 08, 09, 10, 11 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 03
ETC car-tridge
From GT4C-A connector position
To panel / con-nector position
Front ports in CPETS-H panel
Front ports used for TR3 A-interface
Table 14 CPETS-H balanced panels in the TCSM3i cabling cabinet - A-interface (Cont.)
38 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804d10f1
E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H)
ETC 0 B 05.1Z Panel 4 / B03 12, 13, 14, 15 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 04
ETC 2 B 05.1A Panel 4 / B04 16, 17, 18, 19 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 05
ETC 2 B 05.1J Panel 4 / B05 20, 21, 22, 23 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 06
ETC 2 B 05.1R Panel 4 / B06 24, 25, 26, 27 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 07
ETC 2 B 05.1Z Panel 4 / B07 28, 29, 30, 31 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 08
ETC 0 B 06.1A Panel 4 / B08 32, 33, 34, 35 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 09
ETC 0 B 06.1J Panel 4 / B09 36, 37, 38, 39 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 10
ETC 0 B 06.1R Panel 4 / B10 40, 41, 42, 43 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 11
ETC 0 B 06.1Z Panel 4 / B11 44, 45, 46, 47 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 12
ETC 2 B 06.1A Panel 4 / B12 48, 49, 50, 51 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 13
ETC 2 B 06.1J Panel 4 / B13 52, 53, 54, 55 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 14
ETC 2 B 06.1R Panel 4 / B14 56, 57, 58, 59 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 15
ETC 2 B 06.1Z Panel 4 / B15 60, 61, 62, 63 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 16
ETC 0 B 07.1A Panel 4 / B16 64, 65, 66, 67 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 01
ETC 0 B 07.1J Panel 4 / B17 68, 69, 70, 71 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 02
ETC 0 B 07.1R Panel 4 / B18 72, 73, 74, 75 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 03
ETC 0 B 07.1Z Panel 4 / B19 76, 77, 78, 79 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 04
ETC 2 B 07.1A Panel 4 / B20 80, 81, 82, 83 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 05
ETC 2 B 07.1J Panel 4 / B21 84, 85, 86, 87 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 06
ETC 2 B 07.1R Panel 4 / B22 88, 89, 90, 91 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 07
ETC 2 B 07.1Z Panel 4 / B23 92, 93, 94, 95 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 08
ETC 0 B 08.1A Panel 4 / B24 96, 97, 98, 99 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 09
ETC 0 B 08.1J Panel 4 / B25 100, 101, 102, 103 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 10
ETC 0 B 08.1R Panel 4 / B26 104, 105, 106, 107 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 11
ETC 0 B 08.1Z Panel 4 / B27 108, 109, 110, 111 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 12
ETC 2 B 08.1A Panel 4 / B28 112, 113, 114, 115 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 13
ETC 2 B 08.1J Panel 4 / B29 116, 117, 118, 119 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 14
ETC 2 B 08.1R Panel 4 / B30 120, 121, 122, 123 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 15
ETC 2 B 08.1Z Panel 4 / B31 124, 125, 126, 127 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 16
ETC car-tridge
From GT4C-A connector position
To panel / con-nector position
Front ports in CPETS-H panel
Front ports used for TR3 A-interface
Table 14 CPETS-H balanced panels in the TCSM3i cabling cabinet - A-interface (Cont.)
From car-tridge
TR3 unit slot From ET16 slot and connector position
ET panel / front ports through this cable
TC2C 0 01, 02, 03, 04 B 17.1A Panel 4 / 128, 129, 130, 131
Table 15 CPETS-H balanced panels in the TCSM3i cabling cabinet - Ater-interface
DN70617303Issue 1-0
39
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1 (PCM) balanced trunk cable panels (CPETS-G andCPETS-H)
Id:0900d805804d10f1
3.3.2 TCSM3i for combined BSC/TCSM installation optionThe cabling cabinet is not used with the TCSA cabinet in the TCSM3i for combined BSC/TCSM installation option. Instead, the optical cabling from the front connectors of the ETS2 plug-in units is routed out of the cabinet through the CPGO at the cabinet top.
TC2C 0 05, 06, 07, 08 B 17.1J Panel 4 / 132, 133, 134, 135
TC2C 0 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 136, 137, 138, 139
TC2C 0 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 140, 141, 142, 143
TC2C 1 01, 02, 03, 04 B 17.1A Panel 4 / 144, 145, 146, 147
TC2C 1 05, 06, 07, 08 B 17.1J Panel 4 / 148, 149, 150, 151
TC2C 1 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 152, 153, 154, 155
TC2C 1 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 156, 157, 158, 159
TC2C 2 01, 02, 03, 04 B 17.1A Panel 4 / 160, 161, 162, 163
TC2C 2 05, 06, 07, 08 B 17.1J Panel 4 / 164, 165, 166, 167
TC2C 2 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 168, 169, 170, 171
TC2C 2 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 172, 173, 174, 175
TC2C 3 01, 02, 03, 04 B 17.1A Panel 4 / 176, 177, 178, 179
TC2C 3 05, 06, 07, 08 B 17.1J Panel 4 / 180, 181, 182, 183
TC2C 3 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 184, 185, 186, 187
TC2C 3 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 188, 189, 190, 191
TC2C 4 01, 02, 03, 04 B 17.1A Panel 4 / 192, 193, 194, 195
TC2C 4 05, 06, 07, 08 B 17.1J Panel 4 / 196, 197, 198, 199
TC2C 4 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 200, 201, 202, 203
TC2C 4 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 204, 205, 206, 207
TC2C 5 01, 02, 03, 04 B 17.1A Panel 4 / 208, 209, 210, 211
TC2C 5 05, 06, 07, 08 B 17.1J Panel 4 / 212, 213, 214, 215
TC2C 5 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 216, 217, 218, 219
TC2C 5 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 220, 221, 222, 223
Notes
*) Connector positions B 17.1R and B 17.1Z are default positions when the TC2C car-tridge is used for transcoder connections of one BSC.
Connector positions B 18.1A and B 18.1J are in use when the TC2C cartridge is used for transcoder connections of two BSCs (one half of the TC2C cartridge for one BSC and the other half for the other BSC).
From car-tridge
TR3 unit slot From ET16 slot and connector position
ET panel / front ports through this cable
Table 15 CPETS-H balanced panels in the TCSM3i cabling cabinet - Ater-interface
40 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804ebded
E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F)
4 E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F)
4.1 Connector panels CPETS-E and CPETS-F with RJ45 con-nectorsThe small CPETS-E connector panel and the large CPETS-F connector panels are used for E1/T1 (PCM) balanced trunk cables.
Cabling of the CPETS-E panels is described in the cabling lists delivered in the Site Doc-uments binder. The CPETS-E is installed at the BSCC cabinet top (one panel) or in the optional cabling cabinet (a total of four small panels, because there are three small panels in the cabinet and an additional small panel at the cabling cabinet top in first deliveries). The installation of the connector panel at the equipment cabinet top requires the use of Roof adapter (RACP) and the installation of the connector panel at the cabling cabinet top in first deliveries requires the use of Roof adapter 2 (RACP2).
For details of the panel, see figure Connector panel CPETS-E.
Figure 6 Connector panel CPETS-E
Cabling of the CPETS-F panels is described in the cabling lists delivered in the Site Doc-uments binder. The CPETS-F is installed in the optional cabling cabinet.
For details of the panel, see figure Connector panel CPETS-F.
CPETS-E
00 01 02 03 04 05 06 07 08 09 10 11
12 13 14 15 16 17 18 19 20 21 22 23
24 24 26 27 28 29 30 31 32 33 34 35
36 37 38 39 40 41 42 43 44 45 46 47
DN0626746
DN70617303Issue 1-0
41
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1/T1 (PCM) balanced trunk cable panels (CPETS-Eand CPETS-F)
Id:0900d805804ebded
Figure 7 Connector panel CPETS-F
4.2 Flexi BSCDepending on the maximum number ET interfaces, the BSC3i can be used either with or without a cabling cabinet.
CPETS-F00 01 02 03 04 05 06 07 08 09 10 11
12 13 14 15 16 17 18 19 20 21 22 23
24 25 26 27 28 29 30 31 32 33 34 35
36 37 38 39 40 41 42 43 44 45 46 47
48 49 50 51 52 53 54 55 56 57 58 59
60 61 62 63 64 65 66 67
68 69 70 71 72 73 74 75 76 77 78 79
80 81 82 83 84 85 86 87 88 89 90 91
92 93 94 95 96 97 98 99 100 101 102 103
104 105 106 107 108 109 110 111 112 113 114 115
116 117 118 119 120 121 122 123 124 125 126 127
128 129 130 131 132 133 134 135 136 137 138 139
140 141 142 143 144 145 146 147 148 149 150 151
152 153 154 155 156 157 158 159 160 161 162 163
164 165 166 167 168 169 170 171 172 173 174 175
176 177 178 179 180 181 182 183 184 185 186 187
188 189 190 191 192 193 194 195
196 197 198 199 200 201 202 203 204 205 206 207
208 209 210 211 212 213 214 215 216 217 218 219
220 221 222 223 224 225 226 227 228 229 230 231
232 233 234 235 236 237 238 239 240 241 242 243
244 245 246 247 248 249 250 251 252 253 254 255
DN0626407
42 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804ebded
E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F)
4.2.1 Optional cabling cabinet is not usedThe optional cabling cabinet is not needed, if the number ET interfaces needed does not exceed 48.
The E1 and T1 trunk cable connector and in configuration is presented in the following table.
The external trunk cable (from the ET panel) and the connector should meet the require-ments of the UL 1459 standard or the National Electrical Code ANSI/NFPA No.70. The connector should also meet the requirements of the FCC Part 68
Recommended cable type for T1 trunk cable (CNIS) is presented in the following table and figure.
Pin Signal Colour Remarks
1 R Orange/White Incoming direction
2 T White/Orange
3
4 R Blue/White Outgoing direction
5 T White/Blue
6
7
8
Table 16 E1 and T1 trunk cable connector, pin configuration
Cable type: 4 insulated pairs, twisted, double-shielded, cross section 0.4 mm2 (type: Filotex Milliflex3 SH G26/2x4)
Cable connec-tor:
RJ45 modular connector (8-pole)
Table 17 Recommended cable type for T1 trunk cables (CNIS)
DN70617303Issue 1-0
43
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1/T1 (PCM) balanced trunk cable panels (CPETS-Eand CPETS-F)
Id:0900d805804ebded
Figure 8 Single RJ45 connector cable (CNIS cable type) for T1 trunk cables
Recommended cable type for E1 trunk cables (CNIA) is presented in the following table and figure.
Figure 9 RJ45 connector cable (CNIA cable type) with four connectors
The equipping order of the CPETS-E panel at the cabinet in the first deliveries top is pre-sented in the following table.
Cable type: 4x(2x2) insulated pairs, twisted, double-shielded, cross section 0.4 mm2 (type: Milliflex3 SH G26/4)
Cable connec-tor:
RJ45 modular connector plug (8-pole)
Table 18 Recommended cable type for E1 trunk cables (CNIA)
8
MODULAR CONNECTOR
SLEEVE
CABLE
IDENTIFICATIONSTICKER
DN98339941
CONNECTOR
DN00206525
1 2 3 4
44 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804ebded
E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F)
The equipping order of the CPETS-E panel at the cabinet in the upgrade deliveries top is presented in the following table.
4.2.2 Optional cabling cabinet is usedIf more than 48 ET interfaces are needed, the cabling cabinet must be used.
ETC car-tridge
From SGC1C-A connector position
To CPETS-E connector position
Front ports in CPETS-E panel through this cable
Corresponding external ET numbers
ETC 0 B 19.1A B 00 00,01,02,03 ET368,ET369,ET370,ET371
ETC 0 B 19.1J B 01 04,05,06,07 ET372,ET373,ET374,ET375
ETC 0 B 19.1R B 02 08,09,10,11 ET376,ET377,ET378,ET379
ETC 0 B 19.1Z B 03 12,13,14,15 ET380,ET381,ET382,ET383
ETC 0 B 20.1A B 04 16,17,18,19 ET256,ET257,ET258,ET259
ETC 0 B 20.1J B 05 20,21,22,23 ET260,ET261,ET262,ET263
ETC 0 B 20.1R B 06 24,25,26,27 ET264,ET265,ET266,ET267
ETC 0 B 20.1Z B 07 28,29,30,31 ET268,ET269,ET270,ET271
ETC 0 B 21.1A B 08 32,33,34,35 ET272,ET273,ET274,ET275
ETC 0 B 21.1J B 09 36,37,38,39 ET276,ET277,ET278,ET279
ETC 0 B 21.1R B 10 40,41,42,43 ET280,ET281,ET282,ET283
ETC 0 B 21.1Z B 11 44,45,46,47 ET284,ET285,ET286,ET287
Table 19 Balanced panel at the BSCC cabinet top in first deliveries
ETC car-tridge
From GT6C-A connector position
To CPETS-E connector position
Front ports in CPETS-E panel through this cable
Corresponding external ET numbers
ETC 0 B 01.1A B 00 00,01,02,03 ET512,ET513,ET514,ET515
ETC 0 B 01.1J B 01 04,05,06,07 ET516,ET517,ET518,ET519
ETC 0 B 01.1R B 02 08,09,10,11 ET520,ET521,ET522,ET523
ETC 0 B 01.1Z B 03 12,13,14,15 ET524,ET525,ET526,ET527
ETC 0 B 02.1A B 04 16,17,18,19 ET528,ET529,ET530,ET531
ETC 0 B 02.1J B 05 20,21,22,23 ET532,ET533,ET534,ET535
ETC 0 B 02.1R B 06 24,25,26,27 ET536,ET537,ET538,ET539
ETC 0 B 02.1Z B 07 28,29,30,31 ET540,ET541,ET542,ET543
ETC 0 B 03.1A B 08 32,33,34,35 ET544,ET545,ET546,ET547
ETC 0 B 03.1J B 09 36,37,38,39 ET548,ET549,ET550,ET551
ETC 0 B 03.1R B 10 40,41,42,43 ET552,ET553,ET554,ET555
ETC 0 B 03.1Z B 11 44,45,46,47 ET556,ET557,ET558,ET559
Table 20 Balanced panel at the BSCC cabinet top in upgrade deliveries
DN70617303Issue 1-0
45
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1/T1 (PCM) balanced trunk cable panels (CPETS-Eand CPETS-F)
Id:0900d805804ebded
E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F)The following table shows the connector panels in the cabling cabinet.
The cables and the connectors should meet the requirements of the UL 1459 standard or the National Electrical Code ANSI/NFPA No.70. The connectors should also meet the requirements of the FCC Part 68.
Recommended cable type for T1 trunk cable (CNIS) is presented in the following table and figure.
Figure 10 Single RJ45 connector cable (CNIS cable type) for T1 trunk cables
Recommended cable type for E1 trunk cables (CNIA) is presented in the following table and figure.
Panel number
Connector panel
T00 CPETS-E
0 CPETS-F
1 CPETS-E
2 CPETS-E
3 CPETS-E
4 CPETS-F
Table 21 Balanced connector panels in the cabling cabinet
Cable type: 4 insulated pairs, twisted, double-shielded, cross section 0.4 mm2 (type: Filotex Milliflex3 SH G26/2x4)
Cable connec-tor:
RJ45 modular connector (8-pole)
Table 22 Recommended cable type for T1 trunk cables (CNIS)
8
MODULAR CONNECTOR
SLEEVE
CABLE
IDENTIFICATIONSTICKER
DN98339941
46 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804ebded
E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F)
Figure 11 RJ45 connector cable (CNIA cable type) with four connectors
Equipping orderThe equipping order in the cabling cabinet in the first deliveries presented in the follow-ing table.
Cable type: 4x(2x2) insulated pairs, twisted, double-shielded, cross section 0.4 mm2 (type: Milliflex3 SH G26/4)
Cable connec-tor:
RJ45 modular connector plug (8-pole)
Table 23 Recommended cable type for E1 trunk cables (CNIA)
CONNECTOR
DN00206525
1 2 3 4
ETC/GTIC index
From SGC1C-A connector position
To panel / connector position
Front ports in balanced panel through this cable
Corresponding external ET numbers
ETC 0 B 22.1A Panel 00 / B 00 00,01,02,03 ET256,ET257,ET258,ET259
ETC 0 B 22.1J Panel 00 / B 01 04,05,06,07 ET260,ET261,ET262,ET263
ETC 0 B 22.1R Panel 00 / B 02 08,09,10,11 ET264,ET265,ET266,ET267
ETC 0 B 22.1Z Panel 00 / B 03 12,13,14,15 ET268,ET269,ET270,ET271
ETC 0 B 23.1A Panel 00 / B 04 16,17,18,19 ET304,ET305,ET306,ET307
ETC 0 B 23.1J Panel 00 / B 05 20,21,22,23 ET308,ET309,ET310,ET311
ETC 0 B 23.1R Panel 00 / B 06 24,25,26,27 ET312,ET313,ET314,ET315
ETC 0 B 23.1Z Panel 00 / B 07 28,29,30,31 ET316,ET317,ET318,ET319
ETC 0 B 24.1A Panel 00 / B 08 32,33,34,35 ET320,ET321,ET322,ET323
ETC 0 B 24.1J Panel 00 / B 09 36,37,38,39 ET324,ET325,ET326,ET327
ETC 0 B 24.1R Panel 00 / B 10 40,41,42,43 ET328,ET329,ET330,ET331
ETC 0 B 24.1Z Panel 00 / B 11 44,45,46,47 ET332,ET333,ET334,ET335
ETC 0 B 25.1A Panel 00 / B 12 48,49,50,51 ET336,ET337,ET338,ET339
Table 24 Balanced panels in first deliveries
DN70617303Issue 1-0
47
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1/T1 (PCM) balanced trunk cable panels (CPETS-Eand CPETS-F)
Id:0900d805804ebded
ETC 0 B 25.1J Panel 00 / B 13 52,53,54,55 ET340,ET341,ET342,ET343
ETC 0 B 25.1R Panel 00 / B 14 56,57,58,59 ET344,ET345,ET346,ET347
ETC 0 B 25.1Z Panel 00 / B 15 60,61,62,63 ET348,ET349,ET350,ET351
ETC 0 B 26.1A Panel 00 / B 16 64,65,66,67 ET352,ET353,ET354,ET355
ETC 0 B 26.1J Panel 00 / B 17 68,69,70,71 ET356,ET357,ET358,ET359
ETC 0 B 26.1R Panel 00 / B 18 72,73,74,75 ET360,ET361,ET362,ET363
ETC 0 B 26.1Z Panel 00 / B 19 76,77,78,79 ET364,ET365,ET366,ET367
ETC 1 B 28.1A Panel 00 / B 20 80,81,82,83 ET640,ET641,ET642,ET643
ETC 1 B 28.1J Panel 00 / B 21 84,85,86,87 ET644,ET645,ET646,ET647
ETC 1 B 28.1R Panel 00 / B 22 88,89,90,91 ET648,ET649,ET650,ET651
ETC 1 B 28.1Z Panel 00 / B 23 92,93,94,95 ET652,ET653,ET654,ET655
ETC 1 B 29.1A Panel 00 / B 24 96,97,98,99 ET624,ET625,ET626,ET627
ETC 1 B 29.1J Panel 00 / B 25 100,101,102,103 ET628,ET629,ET630,ET631
ETC 1 B 29.1R Panel 00 / B 26 104,105,106,107 ET632,ET633,ET634,ET635
ETC 1 B 29.1Z Panel 00 / B 27 108,109,110,111 ET636,ET637,ET638,ET639
ETC 1 B 30.1A Panel 00 / B 28 112,113,114,115 ET512,ET513,ET514,ET515
ETC 1 B 30.1J Panel 00 / B 29 116,117,118,119 ET516,ET517,ET518,ET519
ETC 1 B 30.1R Panel 00 / B 30 120,121,122,123 ET520,ET521,ET522,ET523
ETC 1 B 30.1Z Panel 00 / B 31 124,125,126,127 ET524,ET525,ET526,ET527
ETC 1 B 31.1A Panel 00 / B 32 128,129,130,131 ET528,ET529,ET530,ET531
ETC 1 B 31.1J Panel 00 / B 33 132,133,134,135 ET532,ET533,ET534,ET535
ETC 1 B 31.1R Panel 00 / B 34 136,137,138,139 ET536,ET537,ET538,ET539
ETC 1 B 31.1Z Panel 00 / B 35 140,141,142,143 ET540,ET541,ET542,ET543
ETC 1 B 32.1A Panel 00 / B 36 144,145,146,147 ET544,ET545,ET546,ET547
ETC 1 B 32.1J Panel 00 / B 37 148,149,150,151 ET548,ET549,ET550,ET551
ETC 1 B 32.1R Panel 00 / B 38 152,153,154,155 ET552,ET553,ET554,ET555
ETC 1 B 32.1Z Panel 00 / B 39 156,157,158,159 ET556,ET557,ET558,ET559
ETC 1 B 33.1A Panel 00 / B 40 160,161,162,163 ET560,ET561,ET562,ET563
ETC 1 B 33.1J Panel 00 / B 41 164,165,166,167 ET564,ET565,ET566,ET567
ETC 1 B 33.1R Panel 00 / B 42 168,169,170,171 ET568,ET569,ET570,ET571
ETC 1 B 33.1Z Panel 00 / B 43 172,173,174,175 ET572,ET573,ET574,ET575
ETC 1 B 34.1A Panel 00 / B 44 176,177,178,179 ET576,ET577,ET578,ET579
ETC 1 B 34.1J Panel 00 / B 45 180,181,182,183 ET580,ET581,ET582,ET583
ETC/GTIC index
From SGC1C-A connector position
To panel / connector position
Front ports in balanced panel through this cable
Corresponding external ET numbers
Table 24 Balanced panels in first deliveries (Cont.)
48 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804ebded
E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F)
ETC 1 B 34.1R Panel 00 / B 46 184,185,186,187 ET584,ET585,ET586,ET587
ETC 1 B 34.1Z Panel 00 / B 47 188,189,190,191 ET588,ET589,ET590,ET591
ETC 1 B 35.1A Panel 00 / B 48 192,193,194,195 ET592,ET593,ET594,ET595
ETC 1 B 35.1J Panel 00 / B 49 196,197,198,199 ET596,ET597,ET598,ET599
ETC 1 B 35.1R Panel 00 / B 50 200,201,202,203 ET600,ET601,ET602,ET603
ETC 1 B 35.1Z Panel 00 / B 51 204,205,206,207 ET604,ET605,ET606,ET607
ETC 1 B 36.1A Panel 00 / B 52 208,209,210,211 ET608,ET609,ET610,ET611
ETC 1 B 36.1J Panel 00 / B 53 212,213,214,215 ET612,ET613,ET614,ET615
ETC 1 B 36.1R Panel 00 / B 54 216,217,218,219 ET616,ET617,ET618,ET619
ETC 1 B 36.1Z Panel 00 / B 55 220,221,222,223 ET620,ET621,ET622,ET623
GTIC 0 B 10.1A Panel 00 / B 56 224,225,226,227 ET1392,ET1393,ET1394,ET1395
GTIC 0 B 10.1J Panel 00 / B 57 228,229,230,231 ET1396,ET1397,ET1398,ET1399
GTIC 0 B 10.1R Panel 00 / B 58 232,233,234,235 ET1400,ET1401,ET1402,ET1403
GTIC 0 B 10.1Z Panel 00 / B 59 236,237,238,239 ET1404,ET1405,ET1406,ET1407
GTIC 0 B 11.1A Panel 00 / B 60 240,241,242,243 ET1280,ET1281,ET1282,ET1283
GTIC 0 B 11.1J Panel 00 / B 61 244,245,246,247 ET1284,ET1285,ET1286,ET1287
GTIC 0 B 11.1R Panel 00 / B 62 248,249,250,251 ET1288,ET1289,ET1290,ET1291
GTIC 0 B 11.1Z Panel 00 / B 63 252,253,254,255 ET1292,ET1293,ET1294,ET1295
GTIC 1 B 10.1A Panel 01 / B 00 00,01,02,03 ET1920,ET1921,ET1922,ET1923
GTIC 1 B 10.1J Panel 01 / B 01 04,05,06,07 ET1924,ET1925,ET1926,ET1927
GTIC 1 B 10.1R Panel 01 / B 02 08,09,10,11 ET1928,ET1929,ET1930,ET1931
GTIC 1 B 10.1Z Panel 01 / B 03 12,13,14,15 ET1932,ET1933,ET1934,ET1935
GTIC 1 B 11.1A Panel 01 / B 04 16,17,18,19 ET1936,ET1937,ET1938,ET1939
GTIC 1 B 11.1J Panel 01 / B 05 20,21,22,23 ET1940,ET1941,ET1942,ET1943
GTIC 1 B 11.1R Panel 01 / B 06 24,25,26,27 ET1944,ET1945,ET1946,ET1947
GTIC 1 B 11.1Z Panel 01 / B 07 28,29,30,31 ET1948,ET1949,ET1950,ET1951
GTIC 1 B 12.1A Panel 01 / B 08 32,33,34,35 ET1952,ET1953,ET1954,ET1955
GTIC 1 B 12.1J Panel 01 / B 09 36,37,38,39 ET1956,ET1957,ET1958,ET1959
GTIC 1 B 12.1R Panel 01 / B 10 40,41,42,43 ET1960,ET1961,ET1962,ET1963
GTIC 1 B 12.1Z Panel 01 / B 11 44,45,46,47 ET1964,ET1965,ET1966,ET1967
GTIC 1 B 13.1A Panel 02 / B 00 00,01,02,03 ET1968,ET1969,ET1970,ET1971
ETC/GTIC index
From SGC1C-A connector position
To panel / connector position
Front ports in balanced panel through this cable
Corresponding external ET numbers
Table 24 Balanced panels in first deliveries (Cont.)
DN70617303Issue 1-0
49
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1/T1 (PCM) balanced trunk cable panels (CPETS-Eand CPETS-F)
Id:0900d805804ebded
GTIC 1 B 13.1J Panel 02 / B 01 04,05,06,07 ET1972,ET1973,ET1974,ET1975
GTIC 1 B 13.1R Panel 02 / B 02 08,09,10,11 ET1976,ET1977,ET1978,ET1979
GTIC 1 B 13.1Z Panel 02 / B 03 12,13,14,15 ET1980,ET1981,ET1982,ET1983
GTIC 1 B 14.1A Panel 02 / B 04 16,17,18,19 ET1984,ET1985,ET1986,ET1987
GTIC 1 B 14.1J Panel 02 / B 05 20,21,22,23 ET1988,ET1989,ET1990,ET1991
GTIC 1 B 14.1R Panel 02 / B 06 24,25,26,27 ET1992,ET1993,ET1994,ET1995
GTIC 1 B 14.1Z Panel 02 / B 07 28,29,30,31 ET1996,ET1997,ET1998,ET1999
GTIC 1 B 15.1A Panel 02 / B 08 32,33,34,35 ET2000,ET2001,ET2002,ET2003
GTIC 1 B 15.1J Panel 02 / B 09 36,37,38,39 ET2004,ET2005,ET2006,ET2007
GTIC 1 B 15.1R Panel 02 / B 10 40,41,42,43 ET2008,ET2009,ET2010,ET2011
GTIC 1 B 15.1Z Panel 02 / B 11 44,45,46,47 ET2012,ET2013,ET2014,ET2015
GTIC 1 B 16.1A Panel 03 / B 00 00,01,02,03 ET2016,ET2017,ET2018,ET2019
GTIC 1 B 16.1J Panel 03 / B 01 04,05,06,07 ET2020,ET2021,ET2022,ET2023
GTIC 1 B 16.1R Panel 03 / B 02 08,09,10,11 ET2024,ET2025,ET2026,ET2027
GTIC 1 B 16.1Z Panel 03 / B 03 12,13,14,15 ET2028,ET2029,ET2030,ET2031
GTIC 1 B 17.1A Panel 03 / B 04 16,17,18,19 ET2032,ET2033,ET2034,ET2035
GTIC 1 B 17.1J Panel 03 / B 05 20,21,22,23 ET2036,ET2037,ET2038,ET2039
GTIC 1 B 17.1R Panel 03 / B 06 24,25,26,27 ET2040,ET2041,ET2042,ET2043
GTIC 1 B 17.1Z Panel 03 / B 07 28,29,30,31 ET2044,ET2045,ET2046,ET2047
ETC 2 B 19.1A Panel 03 / B 08 32,33,34,35 ET1136,ET1137,ET1138,ET1139
ETC 2 B 19.1J Panel 03 / B 09 36,37,38,39 ET1140,ET1141,ET1142,ET1143
ETC 2 B 19.1R Panel 03 / B 10 40,41,42,43 ET1140,ET1141,ET1142,ET1143
ETC 2 B 19.1Z Panel 03 / B 11 44,45,46,47 ET1140,ET1141,ET1142,ET1143
ETC 2 B 20.1A Panel 04 / B 00 00,01,02,03 ET1024,ET1025,ET1026,ET1027
ETC 2 B 20.1J Panel 04 / B 01 04,05,06,07 ET1028,ET1029,ET1030,ET1031
ETC 2 B 20.1R Panel 04 / B 02 08,09,10,11 ET1032,ET1033,ET1034,ET1035
ETC 2 B 20.1Z Panel 04 / B 03 12,13,14,15 ET1036,ET1037,ET1038,ET1039
ETC 2 B 21.1A Panel 04 / B 04 16,17,18,19 ET1040,ET1041,ET1042,ET1043
ETC 2 B 21.1J Panel 04 / B 05 20,21,22,23 ET1044,ET1045,ET1046,ET1047
ETC 2 B 21.1R Panel 04 / B 06 24,25,26,27 ET1048,ET1049,ET1050,ET1051
ETC 2 B 21.1Z Panel 04 / B 07 28,29,30,31 ET1052,ET1053,ET1054,ET1055
ETC/GTIC index
From SGC1C-A connector position
To panel / connector position
Front ports in balanced panel through this cable
Corresponding external ET numbers
Table 24 Balanced panels in first deliveries (Cont.)
50 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804ebded
E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F)
ETC 2 B 22.1A Panel 04 / B 08 32,33,34,35 ET1056,ET1057,ET1058,ET1059
ETC 2 B 22.1J Panel 04 / B 09 36,37,38,39 ET1060,ET1061,ET1062,ET1063
ETC 2 B 22.1R Panel 04 / B 10 40,41,42,43 ET1064,ET1065,ET1066,ET1067
ETC 2 B 22.1Z Panel 04 / B 11 44,45,46,47 ET1068,ET1069,ET1070,ET1071
ETC 2 B 23.1A Panel 04 / B 12 48,49,50,51 ET1072,ET1073,ET1074,ET1075
ETC 2 B 23.1J Panel 04 / B 13 52,53,54,55 ET1076,ET1077,ET1078,ET1079
ETC 2 B 23.1R Panel 04 / B 14 56,57,58,59 ET1080,ET1081,ET1082,ET1083
ETC 2 B 23.1Z Panel 04 / B 15 60,61,62,63 ET1084,ET1085,ET1086,ET1087
ETC 2 B 24.1A Panel 04 / B 16 64,65,66,67 ET1088,ET1089,ET1090,ET1091
ETC 2 B 24.1J Panel 04 / B 17 68,69,70,71 ET1092,ET1093,ET1094,ET1095
ETC 2 B 24.1R Panel 04 / B 18 72,73,74,75 ET1096,ET1097,ET1098,ET1099
ETC 2 B 24.1Z Panel 04 / B 19 76,77,78,79 ET1100,ET1101,ET1102,ET1103
ETC 2 B 25.1A Panel 04 / B 20 80,81,82,83 ET1104,ET1105,ET1106,ET1107
ETC 2 B 25.1J Panel 04 / B 21 84,85,86,87 ET1108,ET1109,ET1110,ET1111
ETC 2 B 25.1R Panel 04 / B 22 88,89,90,91 ET1112,ET1113,ET1114,ET1115
ETC 2 B 25.1Z Panel 04 / B 23 92,93,94,95 ET1116,ET1117,ET1118,ET1119
ETC 2 B 26.1A Panel 04 / B 24 96,97,98,99 ET1120,ET1121,ET1122,ET1123
ETC 2 B 26.1J Panel 04 / B 25 100,101,102,103 ET1124,ET1125,ET1126,ET1127
ETC 2 B 26.1R Panel 04 / B 26 104,105,106,107 ET1128,ET1129,ET1130,ET1131
ETC 2 B 26.1Z Panel 04 / B 27 108,109,110,111 ET1132,ET1133,ET1134,ET1135
ETC 3 B 28.1A Panel 04 / B 28 112,113,114,115 ET896,ET897,ET898,ET899
ETC 3 B 28.1J Panel 04 / B 29 116,117,118,119 ET900,ET901,ET902,ET903
ETC 3 B 28.1R Panel 04 / B 30 120,121,122,123 ET904,ET905,ET906,ET907
ETC 3 B 28.1Z Panel 04 / B 31 124,125,126,127 ET908,ET909,ET910,ET911
ETC 3 B 29.1A Panel 04 / B 32 128,129,130,131 ET880,ET881,ET882,ET883
ETC 3 B 29.1J Panel 04 / B 33 132,133,134,135 ET884,ET885,ET886,ET887
ETC 3 B 29.1R Panel 04 / B 34 136,137,138,139 ET888,ET889,ET890,ET891
ETC 3 B 29.1Z Panel 04 / B 35 140,141,142,143 ET892,ET893,ET894,ET895
ETC 3 B 30.1A Panel 04 / B 36 144,145,146,147 ET768,ET769,ET770,ET771
ETC 3 B 30.1J Panel 04 / B 37 148,149,150,151 ET772,ET773,ET774,ET775
ETC 3 B 30.1R Panel 04 / B 38 152,153,154,155 ET776,ET777,ET778,ET779
ETC 3 B 30.1Z Panel 04 / B 39 156,157,158,159 ET780,ET781,ET782,ET783
ETC 3 B 31.1A Panel 04 / B 40 160,161,162,163 ET784,ET785,ET786,ET787
ETC/GTIC index
From SGC1C-A connector position
To panel / connector position
Front ports in balanced panel through this cable
Corresponding external ET numbers
Table 24 Balanced panels in first deliveries (Cont.)
DN70617303Issue 1-0
51
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1/T1 (PCM) balanced trunk cable panels (CPETS-Eand CPETS-F)
Id:0900d805804ebded
ETC 3 B 31.1J Panel 04 / B 41 164,165,166,167 ET788,ET789,ET790,ET791
ETC 3 B 31.1R Panel 04 / B 42 168,169,170,171 ET792,ET793,ET794,ET795
ETC 3 B 31.1Z Panel 04 / B 43 172,173,174,175 ET796,ET797,ET798,ET799
ETC 3 B 32.1A Panel 04 / B 44 176,177,178,179 ET800,ET801,ET802,ET803
ETC 3 B 32.1J Panel 04 / B 45 180,181,182,183 ET804,ET805,ET806,ET807
ETC 3 B 32.1R Panel 04 / B 46 184,185,186,187 ET808,ET809,ET810,ET811
ETC 3 B 32.1Z Panel 04 / B 47 188,189,190,191 ET812,ET813,ET814,ET815
ETC 3 B 33.1A Panel 04 / B 48 192,193,194,195 ET816,ET817,ET818,ET819
ETC 3 B 33.1J Panel 04 / B 49 196,197,198,199 ET820,ET821,ET822,ET823
ETC 3 B 33.1R Panel 04 / B 50 200,201,202,203 ET824,ET825,ET826,ET827
ETC 3 B 33.1Z Panel 04 / B 51 204,205,206,207 ET828,ET829,ET830,ET831
ETC 3 B 34.1A Panel 04 / B 52 208,209,210,211 ET832,ET833,ET834,ET835
ETC 3 B 34.1J Panel 04 / B 53 212,213,214,215 ET836,ET837,ET838,ET839
ETC 3 B 34.1R Panel 04 / B 54 216,217,218,219 ET840,ET841,ET842,ET843
ETC 3 B 34.1Z Panel 04 / B 55 220,221,222,223 ET844,ET845,ET846,ET847
ETC 3 B 35.1A Panel 04 / B 56 224,225,226,227 ET848,ET849,ET850,ET851
ETC 3 B 35.1J Panel 04 / B 57 228,229,230,231 ET852,ET853,ET854,ET855
ETC 3 B 35.1R Panel 04 / B 58 232,233,234,235 ET856,ET857,ET858,ET859
ETC 3 B 35.1Z Panel 04 / B 59 236,237,238,239 ET860,ET861,ET862,ET863
ETC 3 B 36.1A Panel 04 / B 60 240,241,242,243 ET864,ET865,ET866,ET867
ETC 3 B 36.1J Panel 04 / B 61 244,245,246,247 ET868,ET869,ET870,ET871
ETC 3 B 36.1R Panel 04 / B 62 248,249,250,251 ET872,ET873,ET874,ET875
ETC 3 B 36.1Z Panel 04 / B 63 252,253,254,255 ET876,ET877,ET878,ET879
GTIC 0 B 12.1A Panel T00 / B 00 00,01,02,03 ET1296,ET1297,ET1298,ET1299
GTIC 0 B 12.1J Panel T00 / B 01 04,05,06,07 ET1300,ET1301,ET1302,ET1303
GTIC 0 B 12.1R Panel T00 / B 02 08,09,10,11 ET1304,ET1305,ET1306,ET1307
GTIC 0 B 12.1Z Panel T00 / B 03 12,13,14,15 ET1308,ET1309,ET1310,ET1311
GTIC 0 B 13.1A Panel T00 / B 04 16,17,18,19 ET1312,ET1313,ET1314,ET1315
GTIC 0 B 13.1J Panel T00 / B 05 20,21,22,23 ET1316,ET1317,ET1318,ET1319
GTIC 0 B 13.1R Panel T00 / B 06 24,25,26,27 ET1320,ET1321,ET1322,ET1323
GTIC 0 B 13.1Z Panel T00 / B 07 28,29,30,31 ET1324,ET1325,ET1326,ET1327
GTIC 0 B 14.1A Panel T00 / B 08 32,33,34,35 ET1328,ET1329,ET1330,ET1331
GTIC 0 B 14.1J Panel T00 / B 09 36,37,38,39 ET1332,ET1333,ET1334,ET1335
ETC/GTIC index
From SGC1C-A connector position
To panel / connector position
Front ports in balanced panel through this cable
Corresponding external ET numbers
Table 24 Balanced panels in first deliveries (Cont.)
52 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804ebded
E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F)
The equipping order of the connector panels in the cabling cabinet in upgrade deliveries is presented in the following table.
GTIC 0 B 14.1R Panel T00 / B 10 40,41,42,43 ET1336,ET1337,ET1338,ET1339
GTIC 0 B 14.1Z Panel T00 / B 11 44,45,46,47 ET1340,ET1341,ET1342,ET1343
ETC/GTIC index
From SGC1C-A connector position
To panel / connector position
Front ports in balanced panel through this cable
Corresponding external ET numbers
Table 24 Balanced panels in first deliveries (Cont.)
ETC/GTIC cartridge
From GT4C-A connector position
To panel / connector position
Front ports in balanced panel through this cable
Corresponding external ET numbers
ETC 0 B 04.1A Panel 04 / B 61 244,245,246,247 ET560,ET561,ET562,ET563
ETC 0 B 04.1J Panel 04 / B 62 248,249,250,251 ET564,ET565,ET566,ET567
ETC 0 B 04.1R Panel 04 / B 63 252,253,254,255 ET568,ET569,ET570,ET571
ETC 0 B 04.1Z Panel 04 / B 58 232,233,234,235 ET572,ET573,ET574,ET575
ETC 1 B 01.1A Panel 04 / B 59 236,237,238,239 ET576,ET577,ET578,ET579
ETC 1 B 01.1J Panel 04 / B 60 240,241,242,243 ET580,ET581,ET582,ET583
ETC 1 B 01.1R Panel 04 / B 55 220,221,222,223 ET584,ET585,ET586,ET587
ETC 1 B 01.1Z Panel 04 / B 56 224,225,226,227 ET588,ET589,ET590,ET591
ETC 1 B 02.1A Panel 04 / B 57 228,229,230,231 ET592,ET593,ET594,ET595
ETC 1 B 02.1J Panel 04 / B 52 208,209,210,211 ET596,ET597,ET598,ET599
ETC 1 B 02.1R Panel 04 / B 53 212,213,214,215 ET600,ET601,ET602,ET603
ETC 1 B 02.1Z Panel 04 / B 54 216,217,218,219 ET604,ET605,ET606,ET607
ETC 1 B 03.1A Panel 04 / B 49 196,197,198,199 ET608,ET609,ET610,ET611
ETC 1 B 03.1J Panel 04 / B 50 200,201,202,203 ET612,ET613,ET614,ET615
ETC 1 B 03.1R Panel 04 / B 51 204,205,206,207 ET616,ET617,ET618,ET619
ETC 1 B 03.1Z Panel 04 / B 47 188,189,190,191 ET620,ET621,ET622,ET623
ETC 1 B 04.1A Panel 04 / B 48 192,193,194,195 ET624,ET625,ET626,ET627
ETC 1 B 04.1J Panel 04 / B 44 176,177,178,179 ET628,ET629,ET630,ET631
ETC 1 B 04.1R Panel 04 / B 45 180,181,182,183 ET632,ET633,ET634,ET635
ETC 1 B 04.1Z Panel 04 / B 46 184,185,186,187 ET636,ET637,ET638,ET639
GTIC 0 / ETC 5
B 01.1A (GTIC 0) / B03.1A (ETC 5) Panel 04 / B 41 164,165,166,167 ET904,ET905,ET906,ET907
GTIC 0 / ETC 5
B 01.1J (GTIC 0) / B03.1J (ETC 5) Panel 04 / B 42 168,169,170,171 ET908,ET909,ET910,ET911
GTIC 0 / ETC 5
B 01.1R (GTIC 0) / B03.1R (ETC 5) Panel 04 / B 43 172,173,174,175 ET912,ET913,ET914,ET915
Table 25 Balanced panels in upgrade deliveries
DN70617303Issue 1-0
53
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1/T1 (PCM) balanced trunk cable panels (CPETS-Eand CPETS-F)
Id:0900d805804ebded
GTIC 0 / ETC 5
B 01.1Z (GTIC 0) / B03.1Z (ETC 5) Panel 04 / B 38 152,153,154,155 ET916,ET917,ET918,ET919
GTIC 0 / ETC 5
B 02.1A (GTIC 0) / B04.1A (ETC 5) Panel 04 / B 39 156,157,158,159 ET920,ET921,ET922,ET923
GTIC 0 / ETC 5
B 02.1J (GTIC 0) / B04.1J (ETC 5) Panel 04 / B 40 160,161,162,163 ET924,ET925,ET926,ET927
GTIC 0 / ETC 5
B 02.1R (GTIC 0) / B04.1R (ETC 5) Panel 04 / B 35 140,141,142,143 ET928,ET929,ET930,ET931
GTIC 0 / ETC 5
B 02.1Z (GTIC 0) / B04.1Z (ETC 5) Panel 04 / B 36 144,145,146,147 ET932,ET933,ET934,ET935
GTIC 0 / ETC 5
B 03.1A (GTIC 0) / B05.1A (ETC 5) Panel 04 / B 37 148,149,150,151 ET936,ET937,ET938,ET939
GTIC 0 / ETC 5
B 03.1J (GTIC 0) / B05.1J (ETC 5) Panel 04 / B 32 128,129,130,131 ET940,ET941,ET942,ET943
GTIC 0 / ETC 5
B 03.1R (GTIC 0) / B05.1R (ETC 5) Panel 04 / B 33 132,133,134,135 ET944,ET945,ET946,ET947
GTIC 0 / ETC 5
B 03.1Z (GTIC 0) / B05.1Z (ETC 5) Panel 04 / B 34 136,137,138,139 ET948,ET949,ET950,ET951
GTIC 0 / ETC 5
B 04.1A (GTIC 0) / B06.1A (ETC 5) Panel 04 / B 29 116,117,118,119 ET816,ET817,ET818,ET819
GTIC 0 / ETC 5
B 04.1J (GTIC 0) / B06.1J (ETC 5) Panel 04 / B 30 120,121,122,123 ET820,ET821,ET822,ET823
GTIC 0 / ETC 5
B 04.1R (GTIC 0) / B06.1R (ETC 5) Panel 04 / B 31 124,125,126,127 ET824,ET825,ET826,ET827
GTIC 0 / ETC 5
B 04.1Z (GTIC 0) / B06.1Z (ETC 5) Panel 04 / B 26 104,105,106,107 ET828,ET829,ER830,ET831
GTIC 0 / ETC 5
B 05.1A (GTIC 0) / B07.1A (ETC 5) Panel 04 / B 27 108,109,110,111
ET1072,ET1073,ET1074,ET1075
GTIC 0 / ETC 5
B 05.1J (GTIC 0) / B07.1J (ETC 5) Panel 04 / B 28 112,113,114,115
ET1076,ET1077,ET1078,ET1079
GTIC 0 / ETC 5
B 05.1R (GTIC 0) / B07.1R (ETC 5) Panel 04 / B 23 92,93,94,95
ET1080,ET1081,ET1082,ET1083
GTIC 0 / ETC 5
B 05.1Z (GTIC 0) / B07.1Z (ETC 5) Panel 04 / B 24 96,97,98,99
ET1084,ET1085,ET1086,ET1087
GTIC 0 / ETC 5
B 06.1A (GTIC 0) / B08.1A (ETC 5) Panel 04 / B 25 100,101,102,103
ET1328,ET1329,ET1330,ET1331
GTIC 0 / ETC 5
B 06.1J (GTIC 0) / B08.1J (ETC 5) Panel 04 / B 20 80,81,82,83
ET1332,ET1333,ET1334,ET1335
GTIC 0 / ETC 5
B 06.1R (GTIC 0) / B08.1R (ETC 5) Panel 04 / B 21 84,85,86,87
ET1336,ET1337,ET1338,ET1339
GTIC 0 / ETC 5
B 06.1Z (GTIC 0) / B08.1Z (ETC 5) Panel 04 / B 22 88,89,90,91
ET1340,ET1341,ET1342,ET1343
ETC/GTIC cartridge
From GT4C-A connector position
To panel / connector position
Front ports in balanced panel through this cable
Corresponding external ET numbers
Table 25 Balanced panels in upgrade deliveries (Cont.)
54 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804ebded
E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F)
GTIC 0 B 07.1A Panel 04 / B 17 68,69,70,71ET1792,ET1793,ET1794,ET1795
GTIC 0 B 07.1J Panel 04 / B 18 72,73,74,75ET1796,ET1797,ET1798,ET1799
GTIC 0 B 07.1R Panel 04 / B 19 76,77,78,79ET1800,ET1801,ET1802,ET1803
GTIC 0 B 07.1Z Panel 04 / B 15 60,61,62,63ET1804,ET1805,ET1806,ET1807
GTIC 0 B 08.1A Panel 04 / B 16 64,65,66,67ET1808,ET1809,ET1810,ET1811
GTIC 0 B 08.1J Panel 04 / B 12 48,49,50,51ET1812,ET1813,ET1814,ET1815
GTIC 0 B 08.1R Panel 04 / B 13 52,53,54,55ET1816,ET1817,ET1818,ET1819
GTIC 0 B 08.1Z Panel 04 / B 14 56,57,58,59ET1820,ET1821,ET1822,ET1823
GTIC 1 B 01.1A Panel 04 / B 09 36,37,38,39ET1408,ET1409,ET1410,ET1411
GTIC 1 B 01.1J Panel 04 / B 10 40,41,42,43ET1412,ET1413,ET1414,ET1415
GTIC 1 B 01.1R Panel 04 / B 11 44,45,46,47ET1416,ET1417,ET1418,ET1419
GTIC 1 B 01.1Z Panel 04 / B 06 24,25,26,27ET1420,ET1421,ET1422,ET1423
GTIC 1 B 02.1A Panel 04 / B 07 28,29,30,31ET1424,ET1425,ET1426,ET1427
GTIC 1 B 02.1J Panel 04 / B 08 32,33,34,35ET1428,ET1429,ET1430,ET1431
GTIC 1 B 02.1R Panel 04 / B 03 12,13,14,15ET1432,ET1433,ET1434,ET1435
GTIC 1 B 02.1Z Panel 04 / B 04 16,17,18,19ET1436,ET1437,ET1438,ET1439
GTIC 1 B 03.1A Panel 04 / B 05 20,21,22,23ET1440,ET1441,ET1442,ET1443
GTIC 1 B 03.1J Panel 04 / B 00 00,01,02,03ET1444,ET1445,ET1446,ET1447
GTIC 1 B 03.1R Panel 04 / B 01 04,05,06,07ET1448,ET1449,ET1450,ET1451
GTIC 1 B 03.1Z Panel 04 / B 02 08,09,10,11ET1452,ET1453,ET1454,ET1455
ETC/GTIC cartridge
From GT4C-A connector position
To panel / connector position
Front ports in balanced panel through this cable
Corresponding external ET numbers
Table 25 Balanced panels in upgrade deliveries (Cont.)
DN70617303Issue 1-0
55
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1/T1 (PCM) balanced trunk cable panels (CPETS-Eand CPETS-F)
Id:0900d805804ebded
GTIC 1 B 04.1A Panel 03 / B 09 36,37,38,39ET1456,ET1457,ET1458,ET1459
GTIC 1 B 04.1J Panel 03 / B 10 40,41,42,43ET1460,ET1461,ET1462,ET1463
GTIC 1 B 04.1R Panel 03 / B 11 44,45,46,47ET1464,ET1465,ET1466,ET1467
GTIC 1 B 04.1Z Panel 03 / B 06 24,25,26,27ET1468,ET1469,ET1470,ET1471
GTIC 1 B 05.1A Panel 03 / B 07 28,29,30,31ET1472,ET1473,ET1474,ET1475
GTIC 1 B 05.1J Panel 03 / B 08 32,33,34,35ET1476,ET1477,ET1478,ET1479
GTIC 1 B 05.1R Panel 03 / B 03 12,13,14,15ET1480,ET1481,ET1482,ET1483
GTIC 1 B 05.1Z Panel 03 / B 04 16,17,18,19ET1484,ET1485,ET1486,ET1487
GTIC 1 B 06.1A Panel 03 / B 05 20,21,22,23ET1488,ET1489,ET1490,ET1491
GTIC 1 B 06.1J Panel 03 / B 00 00,01,02,03ET1492,ET1493,ET1494,ET1495
GTIC 1 B 06.1R Panel 03 / B 01 04,05,06,07ET1496,ET1497,ET1498,ET1499
GTIC 1 B 06.1Z Panel 03 / B 02 08,09,10,11ET1500,ET1501,ET1502,ET1503
GTIC 1 B 07.1A Panel 02 / B 09 36,37,38,39ET1504,ET1505,ET1506,ET1507
GTIC 1 B 07.1J Panel 02 / B 10 40,41,42,43ET1508,ET1509,ET1510,ET1511
GTIC 1 B 07.1R Panel 02 / B 11 44,45,46,47ET1512,ET1513,ET1514,ET1515
GTIC 1 B 07.1Z Panel 02 / B 06 24,25,26,27ET1516,ET1517,ET1518,ET1519
GTIC 1 B 08.1A Panel 02 / B 07 28,29,30,31ET1520,ET1521,ET1522,ET1523
GTIC 1 B 08.1J Panel 02 / B 08 32,33,34,35ET1524,ET1525,ET1526,ET1527
GTIC 1 B 08.1R Panel 02 / B 03 12,13,14,15ET1528,ET1529,ET1530,ET1531
GTIC 1 B 08.1Z Panel 02 / B 04 16,17,18,19ET1532,ET1533,ET1534,ET1535
ETC/GTIC cartridge
From GT4C-A connector position
To panel / connector position
Front ports in balanced panel through this cable
Corresponding external ET numbers
Table 25 Balanced panels in upgrade deliveries (Cont.)
56 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804ebded
E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F)
ETC 2 B 01.1A Panel 02 / B 05 20,21,22,23ET1344,ET1345,ET1346,ET1347
ETC 2 B 01.1J Panel 02 / B 00 00,01,02,03ET1348,ET1349,ET1350,ET1351
ETC 2 B 01.1R Panel 02 / B 01 04,05,06,07ET1352,ET1353,ET1354,ET1355
ETC 2 B 01.1Z Panel 02 / B 02 08,09,10,11ET1356,ET1357,ET1358,ET1359
ETC 2 B 02.1A Panel 01 / B 09 36,37,38,39ET1360,ET1361,ET1362,ET1363
ETC 2 B 02.1J Panel 01 / B 10 40,41,42,43ET1364,ET1365,ET1366,ET1367
ETC 2 B 02.1R Panel 01 / B 11 44,45,46,47ET1368,ET1369,ET1370,ET1371
ETC 2 B 02.1Z Panel 01 / B 06 24,25,26,27ET1372,ET1373,ET1374,ET1375
ETC 2 B 03.1A Panel 01 / B 07 28,29,30,31ET1376,ET1377,ET1378,ET1379
ETC 2 B 03.1J Panel 01 / B 08 32,33,34,35ET1380,ET1381,ET1382,ET1383
ETC 2 B 03.1R Panel 01 / B 03 12,13,14,15ET1384,ET1385,ET1386,ET1387
ETC 2 B 03.1Z Panel 01 / B 04 16,17,18,19ET1388,ET1389,ET1390,ET1391
ETC 2 B 04.1A Panel 01 / B 05 20,21,22,23ET1392,ET1393,ET1394,ET1395
ETC 2 B 04.1J Panel 01 / B 00 00,01,02,03ET1396,ET1397,ET1398,ET1399
ETC 2 B 04.1R Panel 01 / B 01 04,05,06,07ET1400,ET1401,ET1402,ET1403
ETC 2 B 04.1Z Panel 01 / B 02 08,09,10,11ET1404,ET1405,ET1406,ET1407
ETC 2 B 05.1A Panel 00 / B 61 244,245,246,247ET1600,ET1601,ET1602,ET1603
ETC 2 B 05.1J Panel 00 / B 62 248,249,250,251ET1604,ET1605,ET1606,ET1607
ETC 2 B 05.1R Panel 00 / B 63 252,253,254,255ET1608,ET1609,ET1610,ET1611
ETC 2 B 05.1Z Panel 00 / B 58 232,233,234,235ET1612,ET1613,ET1614,ET1615
ETC/GTIC cartridge
From GT4C-A connector position
To panel / connector position
Front ports in balanced panel through this cable
Corresponding external ET numbers
Table 25 Balanced panels in upgrade deliveries (Cont.)
DN70617303Issue 1-0
57
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1/T1 (PCM) balanced trunk cable panels (CPETS-Eand CPETS-F)
Id:0900d805804ebded
ETC 2 B 06.1A Panel 00 / B 59 236,237,238,239ET1616,ET1617,ET1618,ET1619
ETC 2 B 06.1J Panel 00 / B 60 240,241,242,243ET1620,ET1621,ET1622,ET1623
ETC 2 B 06.1R Panel 00 / B 55 220,221,222,223ET1624,ET1625,ET1626,ET1627
ETC 2 B 06.1Z Panel 00 / B 56 224,225,226,227ET1628,ET1629,ET1630,ET1631
ETC 2 B 07.1A Panel 00 / B 57 228,229,230,231ET1632,ET1633,ET1634,ET1635
ETC 2 B 07.1J Panel 00 / B 52 208,209,210,211ET1636,ET1637,ET1638,ET1639
ETC 2 B 07.1R Panel 00 / B 53 212,213,214,215ET1640,ET1641,ET1642,ET1643
ETC 2 B 07.1Z Panel 00 / B 54 216,217,218,219ET1644,ET1645,ET1646,ET1647
ETC 2 B 08.1A Panel 00 / B 49 196,197,198,199ET1648,ET1649,ET1650,ET1651
ETC 2 B 08.1J Panel 00 / B 50 200,201,202,203ET1652,ET1653,ET1654,ET1655
ETC 2 B 08.1R Panel 00 / B 51 204,205,206,207ET1656,ET1657,ET1658,ET1659
ETC 2 B 08.1Z Panel 00 / B 47 188,189,190,191ET1660,ET1661,ET1662,ET1663
ETC 3 B 01.1A Panel 00 / B 48 192,193,194,195ET1664,ET1665,ET1666,ET1667
ETC 3 B 01.1J Panel 00 / B 44 176,177,178,179ET1668,ET1669,ET1670,ET1671
ETC 3 B 01.1R Panel 00 / B 45 180,181,182,183ET1672,ET1673,ET1674,ET1675
ETC 3 B 01.1Z Panel 00 / B 46 184,185,186,187ET1676,ET1677,ET1678,ET1679
ETC 3 B 02.1A Panel 00 / B 41 164,165,166,167ET1680,ET1681,ET1682,ET1683
ETC 3 B 02.1J Panel 00 / B 42 168,169,170,171ET1684,ET1685,ET1686,ET1687
ETC 3 B 02.1R Panel 00 / B 43 172,173,174,175ET1688,ET1689,ET1690,ET1691
ETC 3 B 02.1Z Panel 00 / B 38 152,153,154,155ET1692,ET1693,ET1694,ET1695
ETC 3 B 03.1A Panel 00 / B 39 156,157,158,159ET1696,ET1697,ET1698,ET1699
ETC/GTIC cartridge
From GT4C-A connector position
To panel / connector position
Front ports in balanced panel through this cable
Corresponding external ET numbers
Table 25 Balanced panels in upgrade deliveries (Cont.)
58 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804ebded
E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F)
ETC 3 B 03.1J Panel 00 / B 40 160,161,162,163ET1700,ET1701,ET1702,ET1703
ETC 3 B 03.1R Panel 00 / B 35 140,141,142,143ET1704,ET1705,ET1706,ET1707
ETC 3 B 03.1Z Panel 00 / B 36 144,145,146,147ET1708,ET1709,ET1710,ET1711
ETC 3 B 04.1A Panel 00 / B 37 148,149,150,151ET1712,ET1713,ET1714,ET1715
ETC 3 B 04.1J Panel 00 / B 32 128,129,130,131ET1716,ET1717,ET1718,ET1719
ETC 3 B 04.1R Panel 00 / B 33 132,133,134,135ET1720,ET1721,ET1722,ET1723
ETC 3 B 04.1Z Panel 00 / B 34 136,137,138,139ET1724,ET1725,ET1726,ET1727
ETC 3 B 05.1A Panel 00 / B 29 116,117,118,119ET1728,ET1729,ET1730,ET1731
ETC 3 B 05.1J Panel 00 / B 30 120,121,122,123ET1732,ET1733,ET1734,ET1735
ETC 3 B 05.1R Panel 00 / B 31 124,125,126,127ET1736,ET1737,ET1738,ET1739
ETC 3 B 05.1Z Panel 00 / B 26 104,105,106,107ET1740,ET1741,ET1742,ET1743
ETC 3 B 06.1A Panel 00 / B 27 108,109,110,111ET1744,ET1745,ET1746,ET1747
ETC 3 B 06.1J Panel 00 / B 28 112,113,114,115ET1748,ET1749,ET1750,ET1751
ETC 3 B 06.1R Panel 00 / B 23 92,93,94,95ET1752,ET1753,ET1754,ET1755
ETC 3 B 06.1Z Panel 00 / B 24 96,97,98,99ET1756,ET1757,ET1758,ET1759
ETC 3 B 07.1A Panel 00 / B 25 100,101,102,103ET1760,ET1761,ET1762,ET1763
ETC 3 B 07.1J Panel 00 / B 20 80,81,82,83ET1764,ET1765,ET1766,ET1767
ETC 3 B 07.1R Panel 00 / B 21 84,85,86,87ET1768,ET1769,ET1770,ET1771
ETC 3 B 07.1Z Panel 00 / B 22 88,89,90,91ET1772,ET1773,ET1774,ET1775
ETC 3 B 08.1A Panel 00 / B 17 68,69,70,71ET1776,ET1777,ET1778,ET1779
ETC 3 B 08.1J Panel 00 / B 18 72,73,74,75ET1780,ET1781,ET1782,ET1783
ETC/GTIC cartridge
From GT4C-A connector position
To panel / connector position
Front ports in balanced panel through this cable
Corresponding external ET numbers
Table 25 Balanced panels in upgrade deliveries (Cont.)
DN70617303Issue 1-0
59
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1/T1 (PCM) balanced trunk cable panels (CPETS-Eand CPETS-F)
Id:0900d805804ebded
4.3 TCSM3iTwo installation options of the third-generation Transcoder Submultiplexer are available: the TCSM3i for stand-alone installation option and the TCSM3i for combined BSC/TCSM installation option. The TCSM3i for stand-alone installation option always
ETC 3 B 08.1R Panel 00 / B 19 76,77,78,79ET1784,ET1785,ET1786,ET1787
ETC 3 B 08.1Z Panel 00 / B 15 60,61,62,63ET1788,ET1789,ET1790,ET1791
ETC 4 B 01.1A Panel 00 / B 16 64,65,66,67ET1920,ET1921,ET1922,ET1923
ETC 4 B 01.1J Panel 00 / B 12 48,49,50,51ET1924,ET1925,ET1926,ET1927
ETC 4 B 01.1R Panel 00 / B 13 52,53,54,55ET1928,ET1929,ET1930,ET1931
ETC 4 B 01.1Z Panel 00 / B 14 56,57,58,59ET1932,ET1933,ET1934,ET1935
ETC 4 B 02.1A Panel 00 / B 09 36,37,38,39ET1936,ET1937,ET1938,ET1939
ETC 4 B 02.1J Panel 00 / B 10 40,41,42,43ET1940,ET1941,ET1942,ET1943
ETC 4 B 02.1R Panel 00 / B 11 44,45,46,47ET1944,ET1945,ET1946,ET1947
ETC 4 B 02.1Z Panel 00 / B 06 24,25,26,27ET1948,ET1949,ET1950,ET1951
ETC 4 B 03.1A Panel 00 / B 07 28,29,30,31ET1952,ET1953,ET1954,ET1955
ETC 4 B 03.1J Panel 00 / B 08 32,33,34,35ET1956,ET1957,ET1958,ET1959
ETC 4 B 03.1R Panel 00 / B 03 12,13,14,15ET1960,ET1961,ET1962,ET1963
ETC 4 B 03.1Z Panel 00 / B 04 16,17,18,19ET1964,ET1965,ET1966,ET1967
ETC 4 B 04.1A Panel 00 / B 05 20,21,22,23ET1968,ET1969,ET1970,ET1971
ETC 4 B 04.1J Panel 00 / B 00 00,01,02,03ET1972,ET1973,ET1974,ET1975
ETC 4 B 04.1R Panel 00 / B 01 04,05,06,07ET1976,ET1977,ET1978,ET1979
ETC 4 B 04.1Z Panel 00 / B 02 08,09,10,11ET1980,ET1981,ET1982,ET1983
ETC/GTIC cartridge
From GT4C-A connector position
To panel / connector position
Front ports in balanced panel through this cable
Corresponding external ET numbers
Table 25 Balanced panels in upgrade deliveries (Cont.)
60 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804ebded
E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F)
has a cabling cabinet, but the TCSM3i for combined BSC/TCSM installation option does not have a cabling cabinet.
4.3.1 TCSM3i for stand-alone installation optionIn the TCSM3i for stand-alone installation option, the cabling cabinet is always mounted to the TCSA cabinet. Balanced cabling panel is default, whereas the unbalanced is optional and must be ordered separately.
E1/T1 (PCM) balanced trunk cable panel (CPETS-F)Two large balanced CPETS-F panels are used in the cabling cabinet mounted to the TCSA cabinet.
The cables and connectors should meet the requirements of the UL 1459 standard or the National Electrical Code ANSI/NFPA No.70. The connectors should also meet the requirements of the FCC Part 68.
Recommended cable type for T1 trunk cable (CNIS) is presented in the following table figure.
Panel number
Connector panel
0 CPETS-F
1 CPBP
2 CPBP
3 CPBP
4 CPETS-F
Table 26 Balanced connector panels for the TCSM3i
Cable type: 4 insulated pairs, twisted, double-shielded, cross section 0.4 mm2 (type: Filotex Milliflex3 SH G26/2x4)
Cable connector: RJ45 modular connector (8-pole)
Table 27 Recommended cable type for T1 trunk cables (CNIS)
DN70617303Issue 1-0
61
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1/T1 (PCM) balanced trunk cable panels (CPETS-Eand CPETS-F)
Id:0900d805804ebded
Figure 12 Single RJ45 connector cable (CNIS cable type) for T1 trunk cables
Recommended cable type for E1 trunk cables (CNIA) is presented in the following table and figure.
Figure 13 RJ45 connector cable (CNIA cable type) with four connectors
Equipping orderThe cabling cabinet is always used with the TCSM3i for stand-alone installation option. The cabling cabinet and the balanced ET panels are delivered in an optional cabling cabinet set, because TCSA cabinet is a base for both TCSM3i for stand-alone installa-tion option and for TCSM3i for combined BSC/TCSM installation option.
Cable type: 4x(2x2) insulated pairs, twisted, double-shielded, cross section 0.4 mm2 (type: Milliflex3 SH G26/4)
Cable connector: RJ45 modular connector plug (8-pole)
Table 28 Recommended cable type for E1 trunk cables (CNIA)
8
MODULAR CONNECTOR
SLEEVE
CABLE
IDENTIFICATIONSTICKER
DN98339941
CONNECTOR
DN00206525
1 2 3 4
62 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804ebded
E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F)
Equipping of ETs proceeds in steps. The equipping order in the cabling cabinet is pre-sented in the following table.
ETC car-tridge
From GT4C-A connector position
To panel / con-nector position
Front ports in CPETS-F panel through this cable
Front ports used for TR3 A-interface
ETC 0 B 01.1A Panel 0 / B 00 00, 01, 02, 03 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 01
ETC 0 B 01.1J Panel 0 / B 01 04, 05, 06, 07 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 02
ETC 0 B 01.1R Panel 0 / B 02 08, 09, 10, 11 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 03
ETC 0 B 01.1Z Panel 0 / B 03 12, 13, 14, 15 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 04
ETC 1 B 01.1A Panel 0 / B 04 16, 17, 18, 19 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 05
ETC 1 B 01.1J Panel 0 / B 05 20, 21, 22, 23 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 06
ETC 1 B 01.1R Panel 0 / B 06 24, 25, 26, 27 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 07
ETC 1 B 01.1Z Panel 0 / B 07 28, 29, 30, 31 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 08
ETC 2 B 01.1A Panel 0 / B 08 32, 33, 34, 35 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 09
ETC 2 B 01.1J Panel 0 / B 09 36, 37, 38, 39 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 10
ETC 2 B 01.1R Panel 0 / B 10 40, 41, 42, 43 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 11
ETC 2 B 01.1Z Panel 0 / B 11 44, 45, 46, 47 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 12
ETC 1 B 02.1A Panel 0 / B12 48, 49, 50, 51 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 13
ETC 1 B 02.1J Panel 0 / B13 52, 53, 54, 55 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 14
ETC 1 B 02.1R Panel 0 / B14 56, 57, 58, 59 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 15
ETC 1 B 02.1Z Panel 0 / B15 60, 61, 62, 63 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 16
ETC 0 B 02.1A Panel 0 / B16 64, 65, 66, 67 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 01
ETC 0 B 02.1J Panel 0 / B17 68, 69, 70, 71 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 02
ETC 0 B 02.1R Panel 0 / B18 72, 73, 74, 75 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 03
ETC 0 B 02.1Z Panel 0 / B19 76, 77, 78, 79 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 04
ETC 1 B 03.1A Panel 0 / B20 80, 81, 82, 83 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 05
ETC 1 B 03.1J Panel 0 / B21 84, 85, 86, 87 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 06
ETC 1 B 03.1R Panel 0 / B22 88, 89, 90, 91 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 07
ETC 1 B 03.1Z Panel 0 / B23 92, 93, 94, 95 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 08
ETC 2 B 02.1A Panel 0 / B24 96, 97, 98, 99 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 09
ETC 2 B 02.1J Panel 0 / B25 100, 101, 102, 103 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 10
ETC 2 B 02.1R Panel 0 / B26 104, 105, 106, 107 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 11
ETC 2 B 02.1Z Panel 0 / B27 108, 109, 110, 111 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 12
ETC 1 B 04.1A Panel 0 / B28 112, 113, 114, 115 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 13
ETC 1 B 04.1J Panel 0 / B29 116, 117, 118, 119 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 14
ETC 1 B 04.1R Panel 0 / B30 120, 121, 122, 123 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 15
ETC 1 B 04.1Z Panel 0 / B31 124, 125, 126, 127 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 16
Table 29 Balanced panels in the cabling cabinet - A-interface
DN70617303Issue 1-0
63
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1/T1 (PCM) balanced trunk cable panels (CPETS-Eand CPETS-F)
Id:0900d805804ebded
ETC 0 B 03.1A Panel 0 / B32 128, 129, 130, 131 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 01
ETC 0 B 03.1J Panel 0 / B33 132, 133, 134, 135 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 02
ETC 0 B 03.1R Panel 0 / B34 136, 137, 138, 139 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 03
ETC 0 B 03.1Z Panel 0 / B35 140, 141, 142, 143 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 04
ETC 1 B 05.1A Panel 0 / B36 144, 145, 146, 147 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 05
ETC 1 B 05.1J Panel 0 / B37 148, 149, 150, 151 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 06
ETC 1 B 05.1R Panel 0 / B38 152, 153, 154, 155 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 07
ETC 1 B 05.1Z Panel 0 / B39 156, 157, 158, 159 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 08
ETC 2 B 03.1A Panel 0 / B40 160, 161, 162, 163 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 09
ETC 2 B 03.1J Panel 0 / B41 164, 165, 166, 167 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 10
ETC 2 B 03.1R Panel 0 / B42 168, 169, 170, 171 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 11
ETC 2 B 03.1Z Panel 0 / B43 172, 173, 174, 175 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 12
ETC 1 B 06.1A Panel 0 / B44 176, 177, 178, 179 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 13
ETC 1 B 06.1J Panel 0 / B45 180, 181, 182, 183 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 14
ETC 1 B 06.1R Panel 0 / B46 184, 185, 186, 187 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 15
ETC 1 B 06.1Z Panel 0 / B47 188, 189, 190, 191 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 16
ETC 0 B 04.1A Panel 0 / B48 192, 193, 194, 195 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 01
ETC 0 B 04.1J Panel 0 / B49 196, 197, 198, 199 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 02
ETC 0 B 04.1R Panel 0 / B50 200, 201, 102, 103 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 03
ETC 0 B 04.1Z Panel 0 / B51 204, 205, 206, 207 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 04
ETC 1 B 07.1A Panel 0 / B52 208, 209, 120, 211 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 05
ETC 1 B 07.1J Panel 0 / B53 212, 213, 214, 215 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 06
ETC 1 B 07.1R Panel 0 / B54 216, 217, 218, 219 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 07
ETC 1 B 07.1Z Panel 0 / B55 220, 221, 222, 223 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 08
ETC 2 B 04.1A Panel 0 / B56 224, 225, 226, 227 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 09
ETC 2 B 04.1J Panel 0 / B57 228,229, 230, 231 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 10
ETC 2 B 04.1R Panel 0 / B58 232, 233, 234, 235 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 11
ETC 2 B 04.1Z Panel 0 / B59 236, 237, 238, 239 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 12
ETC 1 B 08.1A Panel 0 / B60 240, 241, 242, 243 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 13
ETC 1 B 08.1J Panel 0 / B61 244, 245, 246, 247 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 14
ETC 1 B 08.1R Panel 0 / B62 248, 249, 250, 251 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 15
ETC 1 B 08.1Z Panel 0 / B63 252, 253, 254, 255 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 16
ETC 0 B 05.1A Panel 4 / B00 00, 01, 02, 03 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 01
ETC car-tridge
From GT4C-A connector position
To panel / con-nector position
Front ports in CPETS-F panel through this cable
Front ports used for TR3 A-interface
Table 29 Balanced panels in the cabling cabinet - A-interface (Cont.)
64 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804ebded
E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F)
ETC 0 B 05.1J Panel 4 / B01 04, 05, 06, 07 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 02
ETC 0 B 05.1R Panel 4 / B02 08, 09, 10, 11 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 03
ETC 0 B 05.1Z Panel 4 / B03 12, 13, 14, 15 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 04
ETC 2 B 05.1A Panel 4 / B04 16, 17, 18, 19 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 05
ETC 2 B 05.1J Panel 4 / B05 20, 21, 22, 23 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 06
ETC 2 B 05.1R Panel 4 / B06 24, 25, 26, 27 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 07
ETC 2 B 05.1Z Panel 4 / B07 28, 29, 30, 31 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 08
ETC 0 B 06.1A Panel 4 / B08 32, 33, 34, 35 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 09
ETC 0 B 06.1J Panel 4 / B09 36, 37, 38, 39 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 10
ETC 0 B 06.1R Panel 4 / B10 40, 41, 42, 43 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 11
ETC 0 B 06.1Z Panel 4 / B11 44, 45, 46, 47 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 12
ETC 2 B 06.1A Panel 4 / B12 48, 49, 50, 51 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 13
ETC 2 B 06.1J Panel 4 / B13 52, 53, 54, 55 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 14
ETC 2 B 06.1R Panel 4 / B14 56, 57, 58, 59 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 15
ETC 2 B 06.1Z Panel 4 / B15 60, 61, 62, 63 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 16
ETC 0 B 07.1A Panel 4 / B16 64, 65, 66, 67 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 01
ETC 0 B 07.1J Panel 4 / B17 68, 69, 70, 71 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 02
ETC 0 B 07.1R Panel 4 / B18 72, 73, 74, 75 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 03
ETC 0 B 07.1Z Panel 4 / B19 76, 77, 78, 79 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 04
ETC 2 B 07.1A Panel 4 / B20 80, 81, 82, 83 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 05
ETC 2 B 07.1J Panel 4 / B21 84, 85, 86, 87 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 06
ETC 2 B 07.1R Panel 4 / B22 88, 89, 90, 91 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 07
ETC 2 B 07.1Z Panel 4 / B23 92, 93, 94, 95 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 08
ETC 0 B 08.1A Panel 4 / B24 96, 97, 98, 99 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 09
ETC 0 B 08.1J Panel 4 / B25 100, 101, 102, 103 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 10
ETC 0 B 08.1R Panel 4 / B26 104, 105, 106, 107 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 11
ETC 0 B 08.1Z Panel 4 / B27 108, 109, 110, 111 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 12
ETC 2 B 08.1A Panel 4 / B28 112, 113, 114, 115 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 13
ETC 2 B 08.1J Panel 4 / B29 116, 117, 118, 119 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 14
ETC 2 B 08.1R Panel 4 / B30 120, 121, 122,123 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 15
ETC 2 B 08.1Z Panel 4 / B31 124, 125, 126, 127 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 16
ETC car-tridge
From GT4C-A connector position
To panel / con-nector position
Front ports in CPETS-F panel through this cable
Front ports used for TR3 A-interface
Table 29 Balanced panels in the cabling cabinet - A-interface (Cont.)
DN70617303Issue 1-0
65
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1/T1 (PCM) balanced trunk cable panels (CPETS-Eand CPETS-F)
Id:0900d805804ebded
4.3.2 TCSM3i for combined BSC/TCSM installation optionThe cabling cabinet is not used with the TCSA cabinet in the TCSM3i for combined BSC/TCSM installation option. Instead, the optical cabling from the front connectors of the ETS2 plug-in units is routed out of the cabinet through the CPGO at the cabinet top.
From car-tridge
TR3 unit slot From ET16 slot and connector position
ET panel / front ports through this cable
TC2C 0 01, 02, 03, 04 B 17.1A Panel 4 / 128, 129, 130, 131
TC2C 0 05, 06, 07, 08 B 17.1J Panel 4 / 132, 133, 134, 135
TC2C 0 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 136, 137, 138, 139
TC2C 0 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 140, 141, 142, 143
TC2C 1 01, 02, 03, 04 B 17.1A Panel 4 / 144, 145, 146, 147
TC2C 1 05, 06, 07, 08 B 17.1J Panel 4 / 148, 149, 150, 151
TC2C 1 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 152, 153, 154, 155
TC2C 1 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 156, 157, 158, 159
TC2C 2 01, 02, 03, 04 B 17.1A Panel 4 / 160, 161, 162, 163
TC2C 2 05, 06, 07, 08 B 17.1J Panel 4 / 164, 165, 166, 167
TC2C 2 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 168, 169, 170, 171
TC2C 2 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 172, 173, 174, 175
TC2C 3 01, 02, 03, 04 B 17.1A Panel 4 / 176, 177, 178, 179
TC2C 3 05, 06, 07, 08 B 17.1J Panel 4 / 180, 181, 182, 183
TC2C 3 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 184, 185, 186, 187
TC2C 3 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 188, 189, 190, 191
TC2C 4 01, 02, 03, 04 B 17.1A Panel 4 / 192, 193, 194, 195
TC2C 4 05, 06, 07, 08 B 17.1J Panel 4 / 196, 197, 198, 199
TC2C 4 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 200, 201, 202, 203
TC2C 4 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 204, 205, 206, 207
TC2C 5 01, 02, 03, 04 B 17.1A Panel 4 / 208, 209, 210, 211
TC2C 5 05, 06, 07, 08 B 17.1J Panel 4 / 212, 213, 214, 215
TC2C 5 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 216, 217, 218, 219
TC2C 5 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 220, 221, 222, 223
Notes
*) Connector positions B 17.1R and B 17.1Z are default positions when the TC2C cartridge is used for transcoder connections of one BSC.
Connector positions B 18.1A and B 18.1J are in use when the TC2C cartridge is used for transcoder connections of two BSCs (one half of the TC2C cartridge for one BSC and the other half for the other BSC).
Table 30 Balanced panels in the cabling cabinet - Ater-interface
66 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d8058049ecb0
E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F)
5 E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F)
5.1 Connector panels CPETC-E and CPETC-F with D37 con-nector packsThe small CPETC-E connector panel and the large CPETC-F connector panels are used for E1 (PCM) unbalanced trunk cables.
Cabling of the CPETC-E panels is described in the cabling lists delivered in the Site Doc-uments binder. The CPETC-E is installed at the BSCC cabinet top (one panel) or in the optional cabling cabinet (a total of four small panels, because there are three small panels in the cabinet and an additional small panel at the cabling cabinet top in first deliveries). The installation of the connector panel at the equipment cabinet top requires the use of Roof adapter (RACP) and the installation of the connector panel at the cabling cabinet top in first deliveries requires the use of Roof adapter 2 (RACP2).
For details of the panel, see figure Connector panel CPETC-E.
Figure 14 CPETC-E panel
Cabling of the CPETC-F panels is described in the cabling lists delivered in the Site Doc-uments binder. The CPETC-F is installed in the optional cabling cabinet (two panels). For more information on the panel, see the following figure.
00
02
04
06
08
10
01
03
05
07
09
11
DN05160363 CPETC-E
RxTx RxTx RxTx RxTx
00
78 56 34 12
01 02 03
DN70617303Issue 1-0
67
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1 (PCM) unbalanced trunk cable panels (CPETC-Eand CPETC-F)
Id:0900d8058049ecb0
Figure 15 CPETC-F panel
5.2 Flexi BSCDepending on the maximum number ET interfaces, the Flexi BSC can be used either with or without an optional cabling cabinet.
CPETC-F
00 01 02 03 04 05 06 07
08 09 10 11 12 13 14 15
16 17 18 19 20 21 22 23
24 25 26 27 28 29 30 31
32 33 34 35 36 37 38 39
48 49 50 51 52 53 54 55
56 57 58 59 60 61 62 63
40 41 42 43 44 45 46 47
DN0626419
68 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d8058049ecb0
E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F)
5.2.1 Optional cabling cabinet is not usedThe optional cabling cabinet is not needed, if the number ET interfaces needed does not exceed 48.
The unbalanced (asymmetrical) PCM trunk circuit interfaces are cabled by using coaxial cable connectors from the CPETC-E panels, and the recommended cable type for E1 coaxial trunk cable is CPRD. See the following table and figure.
Figure 16 CPRD cable assembly (panel end connector mounted)
The equipping order of the CPETC-E panel in first deliveries is presented in the following table.
Cable type: Filotex ET 267 380
Cable connector: D37 connector body, type FCI DC8W8PA00; or ITT Cannon DCM-8W8P-A197
Coaxial inserts: Rosenberger 55S101-302E2; IMS 307.23.2415.421
A1 A8
DN99257685
ETC car-tridge
From SGC1C-A connector position
To CPETC-E connector position
Multicoaxial front ports in CPETC-E panel through this cable
Corresponding external ET numbers
ETC 0 B 19.1A B 00 00 (4*ET) ET368,ET369,ET370,ET371
ETC 0 B 19.1J B 01 01 (4*ET) ET372,ET373,ET374,ET375
ETC 0 B 19.1R B 02 02 (4*ET) ET376,ET377,ET378,ET379
ETC 0 B 19.1Z B 03 03 (4*ET) ET380,ET381,ET382,ET383
ETC 0 B 20.1A B 04 04 (4*ET) ET256,ET257,ET258,ET259
ETC 0 B 20.1J B 05 05 (4*ET) ET260,ET261,ET262,ET263
ETC 0 B 20.1R B 06 06 (4*ET) ET264,ET265,ET266,ET267
ETC 0 B 20.1Z B 07 07 (4*ET) ET268,ET269,ET270,ET271
Table 31 Unbalanced panel at the BSCC cabinet top in first deliveries
DN70617303Issue 1-0
69
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1 (PCM) unbalanced trunk cable panels (CPETC-Eand CPETC-F)
Id:0900d8058049ecb0
The equipping order of the CPETC-E panel in upgrade deliveries is presented in the fol-lowing table.
5.2.2 Optional cabling cabinet is usedIf more than 48 ET interfaces are needed, the cabling cabinet must be used with the Flexi BSC.
E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F)The following table shows the connector panels in the cabling cabinet.
ETC 0 B 21.1A B 08 08 (4*ET) ET272,ET273,ET274,ET275
ETC 0 B 21.1J B 09 09 (4*ET) ET276,ET277,ET278,ET279
ETC 0 B 21.1R B 10 10 (4*ET) ET280,ET281,ET282,ET283
ETC 0 B 21.1Z B 11 11 (4*ET) ET284,ET285,ET286,ET287
ETC car-tridge
From SGC1C-A connector position
To CPETC-E connector position
Multicoaxial front ports in CPETC-E panel through this cable
Corresponding external ET numbers
Table 31 Unbalanced panel at the BSCC cabinet top in first deliveries (Cont.)
ETC car-tridge
From GT6C-A connector position
To CPETC-E connec-tor position
Multicoaxial front ports in CPETC-E panel through this cable
Corresponding external ET numbers
ETC 0 B 01.1A B 00 00 (4*ET) ET512,ET513,ET514,ET515
ETC 0 B 01.1J B 01 01 (4*ET) ET516,ET517,ET518,ET519
ETC 0 B 01.1R B 02 02 (4*ET) ET520,ET521,ET522,ET523
ETC 0 B 01.1Z B 03 03 (4*ET) ET524,ET525,ET526,ET527
ETC 0 B 02.1A B 04 04 (4*ET) ET528,ET529,ET530,ET531
ETC 0 B 02.1J B 05 05 (4*ET) ET532,ET533,ET534,ET535
ETC 0 B 02.1R B 06 06 (4*ET) ET536,ET537,ET538,ET539
ETC 0 B 02.1Z B 07 07 (4*ET) ET540,ET541,ET542,ET543
ETC 0 B 03.1A B 08 08 (4*ET) ET544,ET545,ET546,ET547
ETC 0 B 03.1J B 09 09 (4*ET) ET548,ET549,ET550,ET551
ETC 0 B 03.1R B 10 10 (4*ET) ET552,ET553,ET554,ET555
ETC 0 B 03.1Z B 11 11 (4*ET) ET556,ET557,ET558,ET559
Table 32 Unbalanced panel at the BSCC cabinet top in upgrade deliveries
Panel number Connector panel
T00 CPETC-E
Table 33 Unbalanced connector panels for the Flexi BSC
70 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d8058049ecb0
E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F)
The unbalanced (asymmetrical) PCM trunk circuit interfaces are cabled by using coaxial cable connectors from the CPETC-E or CPETC-F panels. The recommended cable type for E1 coaxial trunk cables is CPRD. See the following table and figure.
Figure 17 CPRD cable assembly (panel end connector mounted)
Equipping orderThe equipping order in the cabling cabinet in first deliveries is presented in the following table.
0 CPETC-F
1 CPETC-E
2 CPETC-E
3 CPETC-E
4 CPETC-F
Cable type Filotex ET 267 380
Cable connector D37 connector body, type FCI DC8W8PA00; or ITT Cannon DCM-8W8P-A197
Coaxial inserts Rosenberger 55S101-302E2; IMS 307.23.2415.421
Table 34 Recommended cable type for E1 coaxial trunk cables (CPRD)
Panel number Connector panel
Table 33 Unbalanced connector panels for the Flexi BSC (Cont.)
A1 A8
DN99257685
DN70617303Issue 1-0
71
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1 (PCM) unbalanced trunk cable panels (CPETC-Eand CPETC-F)
Id:0900d8058049ecb0
ETC/GTIC index
From SGC1C-A connector position
To panel / connector position
Multicoaxial front ports in unbalanced panel through this cable
Corresponding external ET numbers
ETC 0 B 22.1A Panel 00 / B 00 00 (4*ET) ET256,ET257,ET258,ET259
ETC 0 B 22.1J Panel 00 / B 01 01 (4*ET) ET260,ET261,ET262,ET263
ETC 0 B 22.1R Panel 00 / B 02 02 (4*ET) ET264,ET265,ET266,ET267
ETC 0 B 22.1Z Panel 00 / B 03 03 (4*ET) ET268,ET269,ET270,ET271
ETC 0 B 23.1A Panel 00 / B 04 04 (4*ET) ET304,ET305,ET306,ET307
ETC 0 B 23.1J Panel 00 / B 05 05 (4*ET) ET308,ET309,ET310,ET311
ETC 0 B 23.1R Panel 00 / B 06 06 (4*ET) ET312,ET313,ET314,ET315
ETC 0 B 23.1Z Panel 00 / B 07 07 (4*ET) ET316,ET317,ET318,ET319
ETC 0 B 24.1A Panel 00 / B 08 08 (4*ET) ET320,ET321,ET322,ET323
ETC 0 B 24.1J Panel 00 / B 09 09 (4*ET) ET324,ET325,ET326,ET327
ETC 0 B 24.1R Panel 00 / B 10 10 (4*ET) ET328,ET329,ET330,ET331
ETC 0 B 24.1Z Panel 00 / B 11 11 (4*ET) ET332,ET333,ET334,ET335
ETC 0 B 25.1A Panel 00 / B 12 12 (4*ET) ET336,ET337,ET338,ET339
ETC 0 B 25.1J Panel 00 / B 13 13 (4*ET) ET340,ET341,ET342,ET343
ETC 0 B 25.1R Panel 00 / B 14 14 (4*ET) ET344,ET345,ET346,ET347
ETC 0 B 25.1Z Panel 00 / B 15 15 (4*ET) ET348,ET349,ET350,ET351
ETC 0 B 26.1A Panel 00 / B 16 16 (4*ET) ET352,ET353,ET354,ET355
ETC 0 B 26.1J Panel 00 / B 17 17 (4*ET) ET356,ET357,ET358,ET359
ETC 0 B 26.1R Panel 00 / B 18 18 (4*ET) ET360,ET361,ET362,ET363
ETC 0 B 26.1Z Panel 00 / B 19 19 (4*ET) ET364,ET365,ET366,ET367
ETC 1 B 28.1A Panel 00 / B 20 20 (4*ET) ET640,ET641,ET642,ET643
ETC 1 B 28.1J Panel 00 / B 21 21 (4*ET) ET644,ET645,ET646,ET647
ETC 1 B 28.1R Panel 00 / B 22 22 (4*ET) ET648,ET649,ET650,ET651
ETC 1 B 28.1Z Panel 00 / B 23 23 (4*ET) ET652,ET653,ET654,ET655
ETC 1 B 29.1A Panel 00 / B 24 24 (4*ET) ET624,ET625,ET626,ET627
ETC 1 B 29.1J Panel 00 / B 25 25 (4*ET) ET628,ET629,ET630,ET631
ETC 1 B 29.1R Panel 00 / B 26 26 (4*ET) ET632,ET633,ET634,ET635
ETC 1 B 29.1Z Panel 00 / B 27 27 (4*ET) ET636,ET637,ET638,ET639
ETC 1 B 30.1A Panel 00 / B 28 28 (4*ET) ET512,ET513,ET514,ET515
ETC 1 B 30.1J Panel 00 / B 29 29 (4*ET) ET516,ET517,ET518,ET519
ETC 1 B 30.1R Panel 00 / B 30 30 (4*ET) ET520,ET521,ET522,ET523
ETC 1 B 30.1Z Panel 00 / B 31 31 (4*ET) ET524,ET525,ET526,ET527
Table 35 Unbalanced panels in first deliveries
72 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d8058049ecb0
E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F)
ETC 1 B 31.1A Panel 00 / B 32 32 (4*ET) ET528,ET529,ET530,ET531
ETC 1 B 31.1J Panel 00 / B 33 33 (4*ET) ET532,ET533,ET534,ET535
ETC 1 B 31.1R Panel 00 / B 34 34 (4*ET) ET536,ET537,ET538,ET539
ETC 1 B 31.1Z Panel 00 / B 35 35 (4*ET) ET540,ET541,ET542,ET543
ETC 1 B 32.1A Panel 00 / B 36 36 (4*ET) ET544,ET545,ET546,ET547
ETC 1 B 32.1J Panel 00 / B 37 37 (4*ET) ET548,ET549,ET550,ET551
ETC 1 B 32.1R Panel 00 / B 38 38 (4*ET) ET552,ET553,ET554,ET555
ETC 1 B 32.1Z Panel 00 / B 39 39 (4*ET) ET556,ET557,ET558,ET559
ETC 1 B 33.1A Panel 00 / B 40 40 (4*ET) ET560,ET561,ET562,ET563
ETC 1 B 33.1J Panel 00 / B 41 41 (4*ET) ET564,ET565,ET566,ET567
ETC 1 B 33.1R Panel 00 / B 42 42 (4*ET) ET568,ET569,ET570,ET571
ETC 1 B 33.1Z Panel 00 / B 43 43 (4*ET) ET572,ET573,ET574,ET575
ETC 1 B 34.1A Panel 00 / B 44 44 (4*ET) ET576,ET577,ET578,ET579
ETC 1 B 34.1J Panel 00 / B 45 45 (4*ET) ET580,ET581,ET582,ET583
ETC 1 B 34.1R Panel 00 / B 46 46 (4*ET) ET584,ET585,ET586,ET587
ETC 1 B 34.1Z Panel 00 / B 47 47 (4*ET) ET588,ET589,ET590,ET591
ETC 1 B 35.1A Panel 00 / B 48 48 (4*ET) ET592,ET593,ET594,ET595
ETC 1 B 35.1J Panel 00 / B 49 49 (4*ET) ET596,ET597,ET598,ET599
ETC 1 B 35.1R Panel 00 / B 50 50 (4*ET) ET600,ET601,ET602,ET603
ETC 1 B 35.1Z Panel 00 / B 51 51 (4*ET) ET604,ET605,ET606,ET607
ETC 1 B 36.1A Panel 00 / B 52 52 (4*ET) ET608,ET609,ET610,ET611
ETC 1 B 36.1J Panel 00 / B 53 53 (4*ET) ET612,ET613,ET614,ET615
ETC 1 B 36.1R Panel 00 / B 54 54 (4*ET) ET616,ET617,ET618,ET619
ETC 1 B 36.1Z Panel 00 / B 55 55 (4*ET) ET620,ET621,ET622,ET623
GTIC 0 B 10.1A Panel 00 / B 56 56 (4*ET) ET1392,ET1393,ET1394,ET1395
GTIC 0 B 10.1J Panel 00 / B 57 57 (4*ET) ET1396,ET1397,ET1398,ET1399
GTIC 0 B 10.1R Panel 00 / B 58 58 (4*ET) ET1400,ET1401,ET1402,ET1403
GTIC 0 B 10.1Z Panel 00 / B 59 59 (4*ET) ET1404,ET1405,ET1406,ET1407
GTIC 0 B 11.1A Panel 00 / B 60 60 (4*ET) ET1280,ET1281,ET1282,ET1283
GTIC 0 B 11.1J Panel 00 / B 61 61 (4*ET) ET1284,ET1285,ET1286,ET1287
GTIC 0 B 11.1R Panel 00 / B 62 62 (4*ET) ET1288,ET1289,ET1290,ET1291
GTIC 0 B 11.1Z Panel 00 / B 63 63 (4*ET) ET1292,ET1293,ET1294,ET1295
ETC/GTIC index
From SGC1C-A connector position
To panel / connector position
Multicoaxial front ports in unbalanced panel through this cable
Corresponding external ET numbers
Table 35 Unbalanced panels in first deliveries (Cont.)
DN70617303Issue 1-0
73
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1 (PCM) unbalanced trunk cable panels (CPETC-Eand CPETC-F)
Id:0900d8058049ecb0
GTIC 1 B 10.1A Panel 01 / B 00 00 (4*ET) ET1920,ET1921,ET1922,ET1923
GTIC 1 B 10.1J Panel 01 / B 01 01 (4*ET) ET1924,ET1925,ET1926,ET1927
GTIC 1 B 10.1R Panel 01 / B 02 02 (4*ET) ET1928,ET1929,ET1930,ET1931
GTIC 1 B 10.1Z Panel 01 / B 03 03 (4*ET) ET1932,ET1933,ET1934,ET1935
GTIC 1 B 11.1A Panel 01 / B 04 04 (4*ET) ET1936,ET1937,ET1938,ET1939
GTIC 1 B 11.1J Panel 01 / B 05 05 (4*ET) ET1940,ET1941,ET1942,ET1943
GTIC 1 B 11.1R Panel 01 / B 06 06 (4*ET) ET1944,ET1945,ET1946,ET1947
GTIC 1 B 11.1Z Panel 01 / B 07 07 (4*ET) ET1948,ET1949,ET1950,ET1951
GTIC 1 B 12.1A Panel 01 / B 08 08 (4*ET) ET1952,ET1953,ET1954,ET1955
GTIC 1 B 12.1J Panel 01 / B 09 09 (4*ET) ET1956,ET1957,ET1958,ET1959
GTIC 1 B 12.1R Panel 01 / B 10 10 (4*ET) ET1960,ET1961,ET1962,ET1963
GTIC 1 B 12.1Z Panel 01 / B 11 11 (4*ET) ET1964,ET1965,ET1966,ET1967
GTIC 1 B 13.1A Panel 02 / B 00 00 (4*ET) ET1968,ET1969,ET1970,ET1971
GTIC 1 B 13.1J Panel 02 / B 01 01 (4*ET) ET1972,ET1973,ET1974,ET1975
GTIC 1 B 13.1R Panel 02 / B 02 02 (4*ET) ET1976,ET1977,ET1978,ET1979
GTIC 1 B 13.1Z Panel 02 / B 03 03 (4*ET) ET1980,ET1981,ET1982,ET1983
GTIC 1 B 14.1A Panel 02 / B 04 04 (4*ET) ET1984,ET1985,ET1986,ET1987
GTIC 1 B 14.1J Panel 02 / B 05 05 (4*ET) ET1988,ET1989,ET1990,ET1991
GTIC 1 B 14.1R Panel 02 / B 06 06 (4*ET) ET1992,ET1993,ET1994,ET1995
GTIC 1 B 14.1Z Panel 02 / B 07 07 (4*ET) ET1996,ET1997,ET1998,ET1999
GTIC 1 B 15.1A Panel 02 / B 08 08 (4*ET) ET2000,ET2001,ET2002,ET2003
GTIC 1 B 15.1J Panel 02 / B 09 09 (4*ET) ET2004,ET2005,ET2006,ET2007
GTIC 1 B 15.1R Panel 02 / B 10 10 (4*ET) ET2008,ET2009,ET2010,ET2011
GTIC 1 B 15.1Z Panel 02 / B 11 11 (4*ET) ET2012,ET2013,ET2014,ET2015
GTIC 1 B 16.1A Panel 03 / B 00 00 (4*ET) ET2016,ET2017,ET2018,ET2019
GTIC 1 B 16.1J Panel 03 / B 01 01 (4*ET) ET2020,ET2021,ET2022,ET2023
GTIC 1 B 16.1R Panel 03 / B 02 02 (4*ET) ET2024,ET2025,ET2026,ET2027
GTIC 1 B 16.1Z Panel 03 / B 03 03 (4*ET) ET2028,ET2029,ET2030,ET2031
GTIC 1 B 17.1A Panel 03 / B 04 04 (4*ET) ET2032,ET2033,ET2034,ET2035
GTIC 1 B 17.1J Panel 03 / B 05 05 (4*ET) ET2036,ET2037,ET2038,ET2039
GTIC 1 B 17.1R Panel 03 / B 06 06 (4*ET) ET2040,ET2041,ET2042,ET2043
GTIC 1 B 17.1Z Panel 03 / B 07 07 (4*ET) ET2044,ET2045,ET2046,ET2047
ETC/GTIC index
From SGC1C-A connector position
To panel / connector position
Multicoaxial front ports in unbalanced panel through this cable
Corresponding external ET numbers
Table 35 Unbalanced panels in first deliveries (Cont.)
74 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d8058049ecb0
E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F)
ETC 2 B 19.1A Panel 03 / B 08 08 (4*ET) ET1136,ET1137,ET1138,ET1139
ETC 2 B 19.1J Panel 03 / B 09 09 (4*ET) ET1140,ET1141,ET1142,ET1143
ETC 2 B 19.1R Panel 03 / B 10 10 (4*ET) ET1140,ET1141,ET1142,ET1143
ETC 2 B 19.1Z Panel 03 / B 11 11 (4*ET) ET1140,ET1141,ET1142,ET1143
ETC 2 B 20.1A Panel 04 / B 00 00 (4*ET) ET1024,ET1025,ET1026,ET1027
ETC 2 B 20.1J Panel 04 / B 01 01 (4*ET) ET1028,ET1029,ET1030,ET1031
ETC 2 B 20.1R Panel 04 / B 02 02 (4*ET) ET1032,ET1033,ET1034,ET1035
ETC 2 B 20.1Z Panel 04 / B 03 03 (4*ET) ET1036,ET1037,ET1038,ET1039
ETC 2 B 21.1A Panel 04 / B 04 04 (4*ET) ET1040,ET1041,ET1042,ET1043
ETC 2 B 21.1J Panel 04 / B 05 05 (4*ET) ET1044,ET1045,ET1046,ET1047
ETC 2 B 21.1R Panel 04 / B 06 06 (4*ET) ET1048,ET1049,ET1050,ET1051
ETC 2 B 21.1Z Panel 04 / B 07 07 (4*ET) ET1052,ET1053,ET1054,ET1055
ETC 2 B 22.1A Panel 04 / B 08 08 (4*ET) ET1056,ET1057,ET1058,ET1059
ETC 2 B 22.1J Panel 04 / B 09 09 (4*ET) ET1060,ET1061,ET1062,ET1063
ETC 2 B 22.1R Panel 04 / B 10 10 (4*ET) ET1064,ET1065,ET1066,ET1067
ETC 2 B 22.1Z Panel 04 / B 11 11 (4*ET) ET1068,ET1069,ET1070,ET1071
ETC 2 B 23.1A Panel 04 / B 12 12 (4*ET) ET1072,ET1073,ET1074,ET1075
ETC 2 B 23.1J Panel 04 / B 13 13 (4*ET) ET1076,ET1077,ET1078,ET1079
ETC 2 B 23.1R Panel 04 / B 14 14 (4*ET) ET1080,ET1081,ET1082,ET1083
ETC 2 B 23.1Z Panel 04 / B 15 15 (4*ET) ET1084,ET1085,ET1086,ET1087
ETC 2 B 24.1A Panel 04 / B 16 16 (4*ET) ET1088,ET1089,ET1090,ET1091
ETC 2 B 24.1J Panel 04 / B 17 17 (4*ET) ET1092,ET1093,ET1094,ET1095
ETC 2 B 24.1R Panel 04 / B 18 18 (4*ET) ET1096,ET1097,ET1098,ET1099
ETC 2 B 24.1Z Panel 04 / B 19 19 (4*ET) ET1100,ET1101,ET1102,ET1103
ETC 2 B 25.1A Panel 04 / B 20 20 (4*ET) ET1104,ET1105,ET1106,ET1107
ETC 2 B 25.1J Panel 04 / B 21 21 (4*ET) ET1108,ET1109,ET1110,ET1111
ETC 2 B 25.1R Panel 04 / B 22 22 (4*ET) ET1112,ET1113,ET1114,ET1115
ETC 2 B 25.1Z Panel 04 / B 23 23 (4*ET) ET1116,ET1117,ET1118,ET1119
ETC 2 B 26.1A Panel 04 / B 24 24 (4*ET) ET1120,ET1121,ET1122,ET1123
ETC 2 B 26.1J Panel 04 / B 25 25 (4*ET) ET1124,ET1125,ET1126,ET1127
ETC 2 B 26.1R Panel 04 / B 26 26 (4*ET) ET1128,ET1129,ET1130,ET1131
ETC 2 B 26.1Z Panel 04 / B 27 27 (4*ET) ET1132,ET1133,ET1134,ET1135
ETC/GTIC index
From SGC1C-A connector position
To panel / connector position
Multicoaxial front ports in unbalanced panel through this cable
Corresponding external ET numbers
Table 35 Unbalanced panels in first deliveries (Cont.)
DN70617303Issue 1-0
75
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1 (PCM) unbalanced trunk cable panels (CPETC-Eand CPETC-F)
Id:0900d8058049ecb0
ETC 3 B 28.1A Panel 04 / B 28 28 (4*ET) ET896,ET897,ET898,ET899
ETC 3 B 28.1J Panel 04 / B 29 29 (4*ET) ET900,ET901,ET902,ET903
ETC 3 B 28.1R Panel 04 / B 30 30 (4*ET) ET904,ET905,ET906,ET907
ETC 3 B 28.1Z Panel 04 / B 31 31 (4*ET) ET908,ET909,ET910,ET911
ETC 3 B 29.1A Panel 04 / B 32 32 (4*ET) ET880,ET881,ET882,ET883
ETC 3 B 29.1J Panel 04 / B 33 33 (4*ET) ET884,ET885,ET886,ET887
ETC 3 B 29.1R Panel 04 / B 34 34 (4*ET) ET888,ET889,ET890,ET891
ETC 3 B 29.1Z Panel 04 / B 35 35 (4*ET) ET892,ET893,ET894,ET895
ETC 3 B 30.1A Panel 04 / B 36 36 (4*ET) ET768,ET769,ET770,ET771
ETC 3 B 30.1J Panel 04 / B 37 37 (4*ET) ET772,ET773,ET774,ET775
ETC 3 B 30.1R Panel 04 / B 38 38 (4*ET) ET776,ET777,ET778,ET779
ETC 3 B 30.1Z Panel 04 / B 39 39 (4*ET) ET780,ET781,ET782,ET783
ETC 3 B 31.1A Panel 04 / B 40 40 (4*ET) ET784,ET785,ET786,ET787
ETC 3 B 31.1J Panel 04 / B 41 41 (4*ET) ET788,ET789,ET790,ET791
ETC 3 B 31.1R Panel 04 / B 42 42 (4*ET) ET792,ET793,ET794,ET795
ETC 3 B 31.1Z Panel 04 / B 43 43 (4*ET) ET796,ET797,ET798,ET799
ETC 3 B 32.1A Panel 04 / B 44 44 (4*ET) ET800,ET801,ET802,ET803
ETC 3 B 32.1J Panel 04 / B 45 45 (4*ET) ET804,ET805,ET806,ET807
ETC 3 B 32.1R Panel 04 / B 46 46 (4*ET) ET808,ET809,ET810,ET811
ETC 3 B 32.1Z Panel 04 / B 47 47 (4*ET) ET812,ET813,ET814,ET815
ETC 3 B 33.1A Panel 04 / B 48 48 (4*ET) ET816,ET817,ET818,ET819
ETC 3 B 33.1J Panel 04 / B 49 49 (4*ET) ET820,ET821,ET822,ET823
ETC 3 B 33.1R Panel 04 / B 50 50 (4*ET) ET824,ET825,ET826,ET827
ETC 3 B 33.1Z Panel 04 / B 51 51 (4*ET) ET828,ET829,ET830,ET831
ETC 3 B 34.1A Panel 04 / B 52 52 (4*ET) ET832,ET833,ET834,ET835
ETC 3 B 34.1J Panel 04 / B 53 53 (4*ET) ET836,ET837,ET838,ET839
ETC 3 B 34.1R Panel 04 / B 54 54 (4*ET) ET840,ET841,ET842,ET843
ETC 3 B 34.1Z Panel 04 / B 55 55 (4*ET) ET844,ET845,ET846,ET847
ETC 3 B 35.1A Panel 04 / B 56 56 (4*ET) ET848,ET849,ET850,ET851
ETC 3 B 35.1J Panel 04 / B 57 57 (4*ET) ET852,ET853,ET854,ET855
ETC 3 B 35.1R Panel 04 / B 58 58 (4*ET) ET856,ET857,ET858,ET859
ETC 3 B 35.1Z Panel 04 / B 59 59 (4*ET) ET860,ET861,ET862,ET863
ETC 3 B 36.1A Panel 04 / B 60 60 (4*ET) ET864,ET865,ET866,ET867
ETC/GTIC index
From SGC1C-A connector position
To panel / connector position
Multicoaxial front ports in unbalanced panel through this cable
Corresponding external ET numbers
Table 35 Unbalanced panels in first deliveries (Cont.)
76 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d8058049ecb0
E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F)
The equipping order in the cabling cabinet in upgrade deliveries is presented in the fol-lowing table.
ETC 3 B 36.1J Panel 04 / B 61 61 (4*ET) ET868,ET869,ET870,ET871
ETC 3 B 36.1R Panel 04 / B 62 62 (4*ET) ET872,ET873,ET874,ET875
ETC 3 B 36.1Z Panel 04 / B 63 63 (4*ET) ET876,ET877,ET878,ET879
GTIC 0 B 12.1A Panel T00 / B 00 00 (4*ET) ET1296,ET1297,ET1298,ET1299
GTIC 0 B 12.1J Panel T00 / B 01 01 (4*ET) ET1300,ET1301,ET1302,ET1303
GTIC 0 B 12.1R Panel T00 / B 02 02 (4*ET) ET1304,ET1305,ET1306,ET1307
GTIC 0 B 12.1Z Panel T00 / B 03 03 (4*ET) ET1308,ET1309,ET1310,ET1311
GTIC 0 B 13.1A Panel T00 / B 04 04 (4*ET) ET1312,ET1313,ET1314,ET1315
GTIC 0 B 13.1J Panel T00 / B 05 05 (4*ET) ET1316,ET1317,ET1318,ET1319
GTIC 0 B 13.1R Panel T00 / B 06 06 (4*ET) ET1320,ET1321,ET1322,ET1323
GTIC 0 B 13.1Z Panel T00 / B 07 07 (4*ET) ET1324,ET1325,ET1326,ET1327
GTIC 0 B 14.1A Panel T00 / B 08 08 (4*ET) ET1328,ET1329,ET1330,ET1331
GTIC 0 B 14.1J Panel T00 / B 09 09 (4*ET) ET1332,ET1333,ET1334,ET1335
GTIC 0 B 14.1R Panel T00 / B 10 10 (4*ET) ET1336,ET1337,ET1338,ET1339
GTIC 0 B 14.1Z Panel T00 / B 11 11 (4*ET) ET1340,ET1341,ET1342,ET1343
ETC/GTIC index
From SGC1C-A connector position
To panel / connector position
Multicoaxial front ports in unbalanced panel through this cable
Corresponding external ET numbers
Table 35 Unbalanced panels in first deliveries (Cont.)
ETC/GTIC cartridge
From GT4C-A connector position
To panel / connector position
Multicoaxial front ports in CPETC-E panel through this cable
Corresponding external ET numbers
ETC 0 B 04.1A Panel 04 / B 56 56 (4*ET) ET560,ET561,ET562,ET563
ETC 0 B 04.1J Panel 04 / B 57 57 (4*ET) ET564,ET565,ET566,ET567
ETC 0 B 04.1R Panel 04 / B 58 58 (4*ET) ET568,ET569,ET570,ET571
ETC 0 B 04.1Z Panel 04 / B 59 59 (4*ET) ET572,ET573,ET574,ET575
ETC 1 B 01.1A Panel 04 / B 60 60 (4*ET) ET576,ET577,ET578,ET579
ETC 1 B 01.1J Panel 04 / B 61 61 (4*ET) ET580,ET581,ET582,ET583
ETC 1 B 01.1R Panel 04 / B 62 62 (4*ET) ET584,ET585,ET586,ET587
ETC 1 B 01.1Z Panel 04 / B 63 63 (4*ET) ET588,ET589,ET590,ET591
ETC 1 B 02.1A Panel 04 / B 48 48 (4*ET) ET592,ET593,ET594,ET595
ETC 1 B 02.1J Panel 04 / B 49 49 (4*ET) ET596,ET597,ET598,ET599
Table 36 Unbalanced panels in upgrade deliveries
DN70617303Issue 1-0
77
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1 (PCM) unbalanced trunk cable panels (CPETC-Eand CPETC-F)
Id:0900d8058049ecb0
ETC 1 B 02.1R Panel 04 / B 50 50 (4*ET) ET600,ET601,ET602,ET603
ETC 1 B 02.1Z Panel 04 / B 51 51 (4*ET) ET604,ET605,ET606,ET607
ETC 1 B 03.1A Panel 04 / B 52 52 (4*ET) ET608,ET609,ET610,ET611
ETC 1 B 03.1J Panel 04 / B 53 53 (4*ET) ET612,ET613,ET614,ET615
ETC 1 B 03.1R Panel 04 / B 54 54 (4*ET) ET616,ET617,ET618,ET619
ETC 1 B 03.1Z Panel 04 / B 55 55 (4*ET) ET620,ET621,ET622,ET623
ETC 1 B 04.1A Panel 04 / B 40 40 (4*ET) ET624,ET625,ET626,ET627
ETC 1 B 04.1J Panel 04 / B 41 41 (4*ET) ET628,ET629,ET630,ET631
ETC 1 B 04.1R Panel 04 / B 42 42 (4*ET) ET632,ET633,ET634,ET635
ETC 1 B 04.1Z Panel 04 / B 43 43 (4*ET) ET636,ET637,ET638,ET639
GTIC 0 / ETC 5
B 01.1A (GTIC 0) / B03.1A (ETC 5) Panel 04 / B 44 44 (4*ET) ET904,ET905,ET906,ET907
GTIC 0 / ETC 5
B 01.1J (GTIC 0) / B03.1J (ETC 5) Panel 04 / B 45 45 (4*ET) ET908,ET909,ET910,ET911
GTIC 0 / ETC 5
B 01.1R (GTIC 0) / B03.1R (ETC 5) Panel 04 / B 46 46 (4*ET) ET912,ET913,ET914,ET915
GTIC 0 / ETC 5
B 01.1Z (GTIC 0) / B03.1Z (ETC 5) Panel 04 / B 47 47 (4*ET) ET916,ET917,ET918,ET919
GTIC 0 / ETC 5
B 02.1A (GTIC 0) / B04.1A (ETC 5) Panel 04 / B 32 32 (4*ET) ET920,ET921,ET922,ET923
GTIC 0 / ETC 5
B 02.1J (GTIC 0) / B04.1J (ETC 5) Panel 04 / B 33 33 (4*ET) ET924,ET925,ET926,ET927
GTIC 0 / ETC 5
B 02.1R (GTIC 0) / B04.1R (ETC 5) Panel 04 / B 34 34 (4*ET) ET928,ET929,ET930,ET931
GTIC 0 / ETC 5
B 02.1Z (GTIC 0) / B04.1Z (ETC 5) Panel 04 / B 35 35 (4*ET) ET932,ET933,ET934,ET935
GTIC 0 / ETC 5
B 03.1A (GTIC 0) / B05.1A (ETC 5) Panel 04 / B 36 36 (4*ET) ET936,ET937,ET938,ET939
GTIC 0 / ETC 5
B 03.1J (GTIC 0) / B05.1J (ETC 5) Panel 04 / B 37 37 (4*ET) ET940,ET941,ET942,ET943
GTIC 0 / ETC 5
B 03.1R (GTIC 0) / B05.1R (ETC 5) Panel 04 / B 38 38 (4*ET) ET944,ET945,ET946,ET947
GTIC 0 / ETC 5
B 03.1Z (GTIC 0) / B05.1Z (ETC 5) Panel 04 / B 39 39 (4*ET) ET948,ET949,ET950,ET951
GTIC 0 / ETC 5
B 04.1A (GTIC 0) / B06.1A (ETC 5) Panel 04 / B 24 24 (4*ET) ET816,ET817,ET818,ET819
GTIC 0 / ETC 5
B 04.1J (GTIC 0) / B06.1J (ETC 5) Panel 04 / B 25 25 (4*ET) ET820,ET821,ET822,ET823
ETC/GTIC cartridge
From GT4C-A connector position
To panel / connector position
Multicoaxial front ports in CPETC-E panel through this cable
Corresponding external ET numbers
Table 36 Unbalanced panels in upgrade deliveries (Cont.)
78 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d8058049ecb0
E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F)
GTIC 0 / ETC 5
B 04.1R (GTIC 0) / B06.1R (ETC 5) Panel 04 / B 26 26 (4*ET) ET824,ET825,ET826,ET827
GTIC 0 / ETC 5
B 04.1Z (GTIC 0) / B06.1Z (ETC 5) Panel 04 / B 27 27 (4*ET) ETET828,ET829,ET830,ET831
GTIC 0 / ETC 5
B 05.1A (GTIC 0) / B07.1A (ETC 5) Panel 04 / B 28 28 (4*ET)
ET1072,ET1073,ET1074,ET1075
GTIC 0 / ETC 5
B 05.1J (GTIC 0) / B07.1J (ETC 5) Panel 04 / B 29 29 (4*ET)
ET1076,ET1077,ET1078,ET1079
GTIC 0 / ETC 5
B 05.1R (GTIC 0) / B07.1R (ETC 5) Panel 04 / B 30 30 (4*ET)
ET1080,ET1081,ET1082,ET1083
GTIC 0 / ETC 5
B 05.1Z (GTIC 0) / B07.1Z (ETC 5) Panel 04 / B 31 31 (4*ET)
ET1084,ET1085,ET1086,ET1087
GTIC 0 / ETC 5
B 06.1A (GTIC 0) / B08.1A (ETC 5) Panel 04 / B 16 16 (4*ET)
ET1328,ET1329,ET1330,ET1331
GTIC 0 / ETC 5
B 06.1J (GTIC 0) / B08.1J (ETC 5) Panel 04 / B 17 17 (4*ET)
ET1332,ET1333,ET1334,ET1335
GTIC 0 / ETC 5
B 06.1R (GTIC 0) / B08.1R (ETC 5) Panel 04 / B 18 18 (4*ET)
ET1336,ET1337,ET1338,ET1339
GTIC 0 / ETC 5
B 06.1Z (GTIC 0) / B08.1Z (ETC 5) Panel 04 / B 19 19 (4*ET)
ET1340,ET1341,ET1342,ET1343
GTIC 0 B 07.1A Panel 04 / B 20 20 (4*ET)ET1792,ET1793,ET1794,ET1795
GTIC 0 B 07.1J Panel 04 / B 21 21 (4*ET)ET1796,ET1797,ET1798,ET1799
GTIC 0 B 07.1R Panel 04 / B 22 22 (4*ET)ET1800,ET1801,ET1802,ET1803
GTIC 0 B 07.1Z Panel 04 / B 23 23 (4*ET)ET1804,ET1805,ET1806,ET1807
GTIC 0 B 08.1A Panel 04 / B 08 08 (4*ET)ET1808,ET1809,ET1810,ET1811
GTIC 0 B 08.1J Panel 04 / B 09 09 (4*ET)ET1812,ET1813,ET1814,ET1815
GTIC 0 B 08.1R Panel 04 / B 10 10 (4*ET)ET1816,ET1817,ET1818,ET1819
GTIC 0 B 08.1Z Panel 04 / B 11 11 (4*ET)ET1820,ET1821,ET1822,ET1823
GTIC 1 B 01.1A Panel 04 / B 12 12 (4*ET)ET1408,ET1409,ET1410,ET1411
GTIC 1 B 01.1J Panel 04 / B 13 13 (4*ET)ET1412,ET1413,ET1414,ET1415
ETC/GTIC cartridge
From GT4C-A connector position
To panel / connector position
Multicoaxial front ports in CPETC-E panel through this cable
Corresponding external ET numbers
Table 36 Unbalanced panels in upgrade deliveries (Cont.)
DN70617303Issue 1-0
79
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1 (PCM) unbalanced trunk cable panels (CPETC-Eand CPETC-F)
Id:0900d8058049ecb0
GTIC 1 B 01.1R Panel 04 / B 14 14 (4*ET)ET1416,ET1417,ET1418,ET1419
GTIC 1 B 01.1Z Panel 04 / B 15 15 (4*ET)ET1420,ET1421,ET1422,ET1423
GTIC 1 B 02.1A Panel 04 / B 00 00 (4*ET)ET1424,ET1425,ET1426,ET1427
GTIC 1 B 02.1J Panel 04 / B 01 01 (4*ET)ET1428,ET1429,ET1430,ET1431
GTIC 1 B 02.1R Panel 04 / B 02 02 (4*ET)ET1432,ET1433,ET1434,ET1435
GTIC 1 B 02.1Z Panel 04 / B 03 03 (4*ET)ET1436,ET1437,ET1438,ET1439
GTIC 1 B 03.1A Panel 04 / B 04 04 (4*ET)ET1440,ET1441,ET1442,ET1443
GTIC 1 B 03.1J Panel 04 / B 05 05 (4*ET)ET1444,ET1445,ET1446,ET1447
GTIC 1 B 03.1R Panel 04 / B 06 06 (4*ET)ET1448,ET1449,ET1450,ET1451
GTIC 1 B 03.1Z Panel 04 / B 07 07 (4*ET)ET1452,ET1453,ET1454,ET1455
GTIC 1 B 04.1A Panel 03 / B 10 10 (4*ET)ET1456,ET1457,ET1458,ET1459
GTIC 1 B 04.1J Panel 03 / B 11 11 (4*ET)ET1460,ET1461,ET1462,ET1463
GTIC 1 B 04.1R Panel 03 / B 08 08 (4*ET)ET1464,ET1465,ET1466,ET1467
GTIC 1 B 04.1Z Panel 03 / B 09 09 (4*ET)ET1468,ET1469,ET1470,ET1471
GTIC 1 B 05.1A Panel 03 / B 06 06 (4*ET)ET1472,ET1473,ET1474,ET1475
GTIC 1 B 05.1J Panel 03 / B 07 07 (4*ET)ET1476,ET1477,ET1478,ET1479
GTIC 1 B 05.1R Panel 03 / B 04 04 (4*ET)ET1480,ET1481,ET1482,ET1483
GTIC 1 B 05.1Z Panel 03 / B 05 05 (4*ET)ET1484,ET1485,ET1486,ET1487
GTIC 1 B 06.1A Panel 03 / B 02 02 (4*ET)ET1488,ET1489,ET1490,ET1491
GTIC 1 B 06.1J Panel 03 / B 03 03 (4*ET)ET1492,ET1493,ET1494,ET1495
ETC/GTIC cartridge
From GT4C-A connector position
To panel / connector position
Multicoaxial front ports in CPETC-E panel through this cable
Corresponding external ET numbers
Table 36 Unbalanced panels in upgrade deliveries (Cont.)
80 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d8058049ecb0
E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F)
GTIC 1 B 06.1R Panel 03 / B 00 00 (4*ET)ET1496,ET1497,ET1498,ET1499
GTIC 1 B 06.1Z Panel 03 / B 01 01 (4*ET)ET1500,ET1501,ET1502,ET1503
GTIC 1 B 07.1A Panel 02 / B 10 10 (4*ET)ET1504,ET1505,ET1506,ET1507
GTIC 1 B 07.1J Panel 02 / B 11 11 (4*ET)ET1508,ET1509,ET1510,ET1511
GTIC 1 B 07.1R Panel 02 / B 08 08 (4*ET)ET1512,ET1513,ET1514,ET1515
GTIC 1 B 07.1Z Panel 02 / B 09 09 (4*ET)ET1516,ET1517,ET1518,ET1519
GTIC 1 B 08.1A Panel 02 / B 06 06 (4*ET)ET1520,ET1521,ET1522,ET1523
GTIC 1 B 08.1J Panel 02 / B 07 07 (4*ET)ET1524,ET1525,ET1526,ET1527
GTIC 1 B 08.1R Panel 02 / B 04 04 (4*ET)ET1528,ET1529,ET1530,ET1531
GTIC 1 B 08.1Z Panel 02 / B 05 05 (4*ET)ET1532,ET1533,ET1534,ET1535
ETC 2 B 01.1A Panel 02 / B 02 02 (4*ET)ET1344,ET1345,ET1346,ET1347
ETC 2 B 01.1J Panel 02 / B 03 03 (4*ET)ET1348,ET1349,ET1350,ET1351
ETC 2 B 01.1R Panel 02 / B 00 00 (4*ET)ET1352,ET1353,ET1354,ET1355
ETC 2 B 01.1Z Panel 02 / B 01 01 (4*ET)ET1356,ET1357,ET1358,ET1359
ETC 2 B 02.1A Panel 01 / B 10 10 (4*ET)ET1360,ET1361,ET1362,ET1363
ETC 2 B 02.1J Panel 01 / B 11 11 (4*ET)ET1364,ET1365,ET1366,ET1367
ETC 2 B 02.1R Panel 01 / B 08 08 (4*ET)ET1368,ET1369,ET1370,ET1371
ETC 2 B 02.1Z Panel 01 / B 09 09 (4*ET)ET1372,ET1373,ET1374,ET1375
ETC 2 B 03.1A Panel 01 / B 06 06 (4*ET)ET1376,ET1377,ET1378,ET1379
ETC/GTIC cartridge
From GT4C-A connector position
To panel / connector position
Multicoaxial front ports in CPETC-E panel through this cable
Corresponding external ET numbers
Table 36 Unbalanced panels in upgrade deliveries (Cont.)
DN70617303Issue 1-0
81
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1 (PCM) unbalanced trunk cable panels (CPETC-Eand CPETC-F)
Id:0900d8058049ecb0
ETC 2 B 03.1J Panel 01 / B 07 07 (4*ET)ET1380,ET1381,ET1382,ET1383
ETC 2 B 03.1R Panel 01 / B 04 04 (4*ET)ET1384,ET1385,ET1386,ET1387
ETC 2 B 03.1Z Panel 01 / B 05 05 (4*ET)ET1388,ET1389,ET1390,ET1391
ETC 2 B 04.1A Panel 01 / B 02 02 (4*ET)ET1392,ET1393,ET1394,ET1395
ETC 2 B 04.1J Panel 01 / B 03 03 (4*ET)ET1396,ET1397,ET1398,ET1399
ETC 2 B 04.1R Panel 01 / B 00 00 (4*ET)ET1400,ET1401,ET1402,ET1403
ETC 2 B 04.1Z Panel 01 / B 01 01 (4*ET)ET1404,ET1405,ET1406,ET1407
ETC 2 B 05.1A Panel 00 / B 56 56 (4*ET)ET1600,ET1601,ET1602,ET1603
ETC 2 B 05.1J Panel 00 / B 57 57 (4*ET)ET1604,ET1605,ET1606,ET1607
ETC 2 B 05.1R Panel 00 / B 58 58 (4*ET)ET1608,ET1609,ET1610,ET1611
ETC 2 B 05.1Z Panel 00 / B 59 59 (4*ET)ET1612,ET1613,ET1614,ET1615
ETC 2 B 06.1A Panel 00 / B 60 60 (4*ET)ET1616,ET1617,ET1618,ET1619
ETC 2 B 06.1J Panel 00 / B 61 61 (4*ET)ET1620,ET1621,ET1622,ET1623
ETC 2 B 06.1R Panel 00 / B 62 62 (4*ET)ET1624,ET1625,ET1626,ET1627
ETC 2 B 06.1Z Panel 00 / B 63 63 (4*ET)ET1628,ET1629,ET1630,ET1631
ETC 2 B 07.1A Panel 00 / B 48 48 (4*ET)ET1632,ET1633,ET1634,ET1635
ETC 2 B 07.1J Panel 00 / B 49 49 (4*ET)ET1636,ET1637,ET1638,ET1639
ETC 2 B 07.1R Panel 00 / B 50 50 (4*ET)ET1640,ET1641,ET1642,ET1643
ETC 2 B 07.1Z Panel 00 / B 51 51 (4*ET)ET1644,ET1645,ET1646,ET1647
ETC 2 B 08.1A Panel 00 / B 52 52 (4*ET)ET1648,ET1649,ET1650,ET1651
ETC/GTIC cartridge
From GT4C-A connector position
To panel / connector position
Multicoaxial front ports in CPETC-E panel through this cable
Corresponding external ET numbers
Table 36 Unbalanced panels in upgrade deliveries (Cont.)
82 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d8058049ecb0
E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F)
ETC 2 B 08.1J Panel 00 / B 53 53 (4*ET)ET1652,ET1653,ET1654,ET1655
ETC 2 B 08.1R Panel 00 / B 54 54 (4*ET)ET1656,ET1657,ET1658,ET1659
ETC 2 B 08.1Z Panel 00 / B 55 55 (4*ET)ET1660,ET1661,ET1662,ET1663
ETC 3 B 01.1A Panel 00 / B 40 40 (4*ET)ET1664,ET1665,ET1666,ET1667
ETC 3 B 01.1J Panel 00 / B 41 41 (4*ET)ET1668,ET1669,ET1670,ET1671
ETC 3 B 01.1R Panel 00 / B 42 42 (4*ET)ET1672,ET1673,ET1674,ET1675
ETC 3 B 01.1Z Panel 00 / B 43 43 (4*ET)ET1676,ET1677,ET1678,ET1679
ETC 3 B 02.1A Panel 00 / B 44 44 (4*ET)ET1680,ET1681,ET1682,ET1683
ETC 3 B 02.1J Panel 00 / B 45 45 (4*ET)ET1684,ET1685,ET1686,ET1687
ETC 3 B 02.1R Panel 00 / B 46 46 (4*ET)ET1688,ET1689,ET1690,ET1691
ETC 3 B 02.1Z Panel 00 / B 47 47 (4*ET)ET1692,ET1693,ET1694,ET1695
ETC 3 B 03.1A Panel 00 / B 32 32 (4*ET)ET1696,ET1697,ET1698,ET1699
ETC 3 B 03.1J Panel 00 / B 33 33 (4*ET)ET1700,ET1701,ET1702,ET1703
ETC 3 B 03.1R Panel 00 / B 34 34 (4*ET)ET1704,ET1705,ET1706,ET1707
ETC 3 B 03.1Z Panel 00 / B 35 35 (4*ET)ET1708,ET1709,ET1710,ET1711
ETC 3 B 04.1A Panel 00 / B 36 36 (4*ET)ET1712,ET1713,ET1714,ET1715
ETC 3 B 04.1J Panel 00 / B 37 37 (4*ET)ET1716,ET1717,ET1718,ET1719
ETC 3 B 04.1R Panel 00 / B 38 38 (4*ET)ET1720,ET1721,ET1722,ET1723
ETC 3 B 04.1Z Panel 00 / B 39 39 (4*ET)ET1724,ET1725,ET1726,ET1727
ETC 3 B 05.1A Panel 00 / B 24 24 (4*ET)ET1728,ET1729,ET1730,ET1731
ETC/GTIC cartridge
From GT4C-A connector position
To panel / connector position
Multicoaxial front ports in CPETC-E panel through this cable
Corresponding external ET numbers
Table 36 Unbalanced panels in upgrade deliveries (Cont.)
DN70617303Issue 1-0
83
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1 (PCM) unbalanced trunk cable panels (CPETC-Eand CPETC-F)
Id:0900d8058049ecb0
ETC 3 B 05.1J Panel 00 / B 25 25 (4*ET)ET1732,ET1733,ET1734,ET1735
ETC 3 B 05.1R Panel 00 / B 26 26 (4*ET)ET1736,ET1737,ET1738,ET1739
ETC 3 B 05.1Z Panel 00 / B 27 27 (4*ET)ET1740,ET1741,ET1742,ET1743
ETC 3 B 06.1A Panel 00 / B 28 28 (4*ET)ET1744,ET1745,ET1746,ET1747
ETC 3 B 06.1J Panel 00 / B 29 29 (4*ET)ET1748,ET1749,ET1750,ET1751
ETC 3 B 06.1R Panel 00 / B 30 30 (4*ET)ET1752,ET1753,ET1754,ET1755
ETC 3 B 06.1Z Panel 00 / B 31 31 (4*ET)ET1756,ET1757,ET1758,ET1759
ETC 3 B 07.1A Panel 00 / B 16 16 (4*ET)ET1760,ET1761,ET1762,ET1763
ETC 3 B 07.1J Panel 00 / B 17 17 (4*ET)ET1764,ET1765,ET1766,ET1767
ETC 3 B 07.1R Panel 00 / B 18 18 (4*ET)ET1768,ET1769,ET1770,ET1771
ETC 3 B 07.1Z Panel 00 / B 19 19 (4*ET)ET1772,ET1773,ET1774,ET1775
ETC 3 B 08.1A Panel 00 / B 20 20 (4*ET)ET1776,ET1777,ET1778,ET1779
ETC 3 B 08.1J Panel 00 / B 21 21 (4*ET)ET1780,ET1781,ET1782,ET1783
ETC 3 B 08.1R Panel 00 / B 22 22 (4*ET)ET1784,ET1785,ET1786,ET1787
ETC 3 B 08.1Z Panel 00 / B 23 23 (4*ET)ET1788,ET1789,ET1790,ET1791
ETC 4 B 01.1A Panel 00 / B 08 08 (4*ET)ET1920,ET1921,ET1922,ET1923
ETC 4 B 01.1J Panel 00 / B 09 09 (4*ET)ET1924,ET1925,ET1926,ET1927
ETC 4 B 01.1R Panel 00 / B 10 10 (4*ET)ET1928,ET1929,ET1930,ET1931
ETC 4 B 01.1Z Panel 00 / B 11 11 (4*ET)ET1932,ET1933,ET1934,ET1935
ETC 4 B 02.1A Panel 00 / B 12 12 (4*ET)ET1936,ET1937,ET1938,ET1939
ETC/GTIC cartridge
From GT4C-A connector position
To panel / connector position
Multicoaxial front ports in CPETC-E panel through this cable
Corresponding external ET numbers
Table 36 Unbalanced panels in upgrade deliveries (Cont.)
84 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d8058049ecb0
E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F)
5.3 TCSM3iTwo installation options of the third-generation Transcoder Submultiplexer are available: the TCSM3i for stand-alone installation option and the TCSM3i for combined BSC/TCSM installation option. The TCSM3i for stand-alone installation option always has a cabling cabinet, but the TCSM3i for combined BSC/TCSM installation option does not have a cabling cabinet.
5.3.1 TCSM3i for stand-alone installation optionIn the TCSM3i for stand-alone installation option, the cabling cabinet is always mounted to the TCSA cabinet. Balanced cabling panel is default, whereas the unbalanced is optional and must be ordered separately.
E1 (PCM) unbalanced trunk cable panel (CPETC-F)The unbalanced connector panels for the TCSM3i are shown in the following table.
ETC 4 B 02.1J Panel 00 / B 13 13 (4*ET)ET1940,ET1941,ET1942,ET1943
ETC 4 B 02.1R Panel 00 / B 14 14 (4*ET)ET1944,ET1945,ET1946,ET1947
ETC 4 B 02.1Z Panel 00 / B 15 15 (4*ET)ET1948,ET1949,ET1950,ET1951
ETC 4 B 03.1A Panel 00 / B 00 00 (4*ET)ET1952,ET1953,ET1954,ET1955
ETC 4 B 03.1J Panel 00 / B 01 01 (4*ET)ET1956,ET1957,ET1958,ET1959
ETC 4 B 03.1R Panel 00 / B 02 02 (4*ET)ET1960,ET1961,ET1962,ET1963
ETC 4 B 03.1Z Panel 00 / B 03 03 (4*ET)ET1964,ET1965,ET1966,ET1967
ETC 4 B 04.1A Panel 00 / B 04 04 (4*ET)ET1968,ET1969,ET1970,ET1971
ETC 4 B 04.1J Panel 00 / B 05 05 (4*ET)ET1972,ET1973,ET1974,ET1975
ETC 4 B 04.1R Panel 00 / B 06 06 (4*ET)ET1976,ET1977,ET1978,ET1979
ETC 4 B 04.1Z Panel 00 / B 07 07 (4*ET)ET1980,ET1981,ET1982,ET1983
ETC/GTIC cartridge
From GT4C-A connector position
To panel / connector position
Multicoaxial front ports in CPETC-E panel through this cable
Corresponding external ET numbers
Table 36 Unbalanced panels in upgrade deliveries (Cont.)
DN70617303Issue 1-0
85
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1 (PCM) unbalanced trunk cable panels (CPETC-Eand CPETC-F)
Id:0900d8058049ecb0
Recommended cable type for E1 coaxial trunk cables is CPRD. See the following table and figure.
Figure 18 CPRD cable assembly (panel end connector mounted)
Equipping orderThe cabling cabinet is used with the TCSM3i for stand-alone installation option.
The D-connector in the unbalanced panels is shown in the following figure and the equipping order in the cabling cabinet is presented in the following table.
Panel number
Connector panel
0 CPETC-F
1 CPBP
2 CPBP
3 CPBP
4 CPETC-F
Table 37 Unbalanced connector panels for the TCSM3i
Cable type Filotex ET 267 380
Cable connector D37 connector body, type FCI DC8W8PA00; or ITT Cannon DCM-8W8P-A197
Coaxial inserts Rosenberger 55S101-302E2; IMS 307.23.2415.421
Table 38 Recommended cable type for E1 coaxial trunk cables (CPRD)
A1 A8
DN99257685
86 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d8058049ecb0
E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F)
DN70617303Issue 1-0
87
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1 (PCM) unbalanced trunk cable panels (CPETC-Eand CPETC-F)
Id:0900d8058049ecb0
Figure 19 D-connector
ETC car-tridge
From GT4C-A connector position
To panel / connector position
Multicoaxial front ports in CPETC-F panel through this cable
Coaxial insert pairs of the Multicoaxial front ports used by
ETC 0 B 01.1A Panel 0 / B 00 00 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 01
ETC 0 B 01.1J Panel 0 / B 01 01 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 02
ETC 0 B 01.1R Panel 0 / B 02 02 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 03
ETC 0 B 01.1Z Panel 0 / B 03 03 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 04
ETC 1 B 01.1A Panel 0 / B 04 04 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 05
ETC 1 B 01.1J Panel 0 / B 05 05 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 06
ETC 1 B 01.1R Panel 0 / B 06 06 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 07
ETC 1 B 01.1Z Panel 0 / B 07 07 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 08
ETC 2 B 01.1A Panel 0 / B 08 08 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 09
ETC 2 B 01.1J Panel 0 / B 09 09 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 10
ETC 2 B 01.1R Panel 0 / B 10 10 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 11
ETC 2 B 01.1Z Panel 0 / B 11 11 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 12
ETC 1 B 02.1A Panel 0 / B12 12 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 13
ETC 1 B 02.1J Panel 0 / B13 13 (4*ET) A-interf. PCM1-4/ TR3 in TC2C0 slot 14
ETC 1 B 02.1R Panel 0 / B14 14 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 15
ETC 1 B 02.1Z Panel 0 / B15 15 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 16
ETC 0 B 02.1A Panel 0 / B16 16 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 01
ETC 0 B 02.1J Panel 0 / B17 17 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 02
ETC 0 B 02.1R Panel 0 / B18 18 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 03
ETC 0 B 02.1Z Panel 0 / B19 19 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 04
ETC 1 B 03.1A Panel 0 / B20 20 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 05
ETC 1 B 03.1J Panel 0 / B21 21 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 06
ETC 1 B 03.1R Panel 0 / B22 22 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 07
ETC 1 B 03.1Z Panel 0 / B23 23 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 08
ETC 2 B 02.1A Panel 0 / B24 24 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 09
ETC 2 B 02.1J Panel 0 / B25 25 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 10
ETC 2 B 02.1R Panel 0 / B26 26 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 11
ETC 2 B 02.1Z Panel 0 / B27 27 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 12
ETC 1 B 04.1A Panel 0 / B28 28 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 13
ETC 1 B 04.1J Panel 0 / B29 29 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 14
ETC 1 B 04.1R Panel 0 / B30 30 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 15
Table 39 Unbalanced panels in cabling cabinet - A-interface
88 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d8058049ecb0
E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F)
ETC 1 B 04.1Z Panel 0 / B31 31 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 16
ETC 0 B 03.1A Panel 0 / B32 32 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 01
ETC 0 B 03.1J Panel 0 / B33 33 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 02
ETC 0 B 03.1R Panel 0 / B34 34 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 03
ETC 0 B 03.1Z Panel 0 / B35 35 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 04
ETC 1 B 05.1A Panel 0 / B36 36 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 05
ETC 1 B 05.1J Panel 0 / B37 37 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 06
ETC 1 B 05.1R Panel 0 / B38 38 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 07
ETC 1 B 05.1Z Panel 0 / B39 39 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 08
ETC 2 B 03.1A Panel 0 / B40 40 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 09
ETC 2 B 03.1J Panel 0 / B41 41 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 10
ETC 2 B 03.1R Panel 0 / B42 42 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 11
ETC 2 B 03.1Z Panel 0 / B43 43 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 12
ETC 1 B 06.1A Panel 0 / B44 44 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 13
ETC 1 B 06.1J Panel 0 / B45 45 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 14
ETC 1 B 06.1R Panel 0 / B46 46 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 15
ETC 1 B 06.1Z Panel 0 / B47 47 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 16
ETC 0 B 04.1A Panel 0 / B48 48 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 01
ETC 0 B 04.1J Panel 0 / B49 49 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 02
ETC 0 B 04.1R Panel 0 / B50 50 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 03
ETC 0 B 04.1Z Panel 0 / B51 51 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 04
ETC 1 B 07.1A Panel 0 / B52 52 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 05
ETC 1 B 07.1J Panel 0 / B53 53 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 06
ETC 1 B 07.1R Panel 0 / B54 54 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 07
ETC 1 B 07.1Z Panel 0 / B55 55 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 08
ETC 2 B 04.1A Panel 0 / B56 56 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 09
ETC 2 B 04.1J Panel 0 / B57 57 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 10
ETC 2 B 04.1R Panel 0 / B58 58 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 11
ETC 2 B 04.1Z Panel 0 / B59 59 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 12
ETC 1 B 08.1A Panel 0 / B60 60 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 13
ETC 1 B 08.1J Panel 0 / B61 61 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 14
ETC 1 B 08.1R Panel 0 / B62 62 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 15
ETC 1 B 08.1Z Panel 0 / B63 63 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 16
ETC car-tridge
From GT4C-A connector position
To panel / connector position
Multicoaxial front ports in CPETC-F panel through this cable
Coaxial insert pairs of the Multicoaxial front ports used by
Table 39 Unbalanced panels in cabling cabinet - A-interface (Cont.)
DN70617303Issue 1-0
89
Connector Panels and External Cables in Flexi BSC and TCSM3i
E1 (PCM) unbalanced trunk cable panels (CPETC-Eand CPETC-F)
Id:0900d8058049ecb0
ETC 0 B 05.1A Panel 4 / B00 00 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 01
ETC 0 B 05.1J Panel 4 / B01 01 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 02
ETC 0 B 05.1R Panel 4 / B02 02 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 03
ETC 0 B 05.1Z Panel 4 / B03 03 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 04
ETC 2 B 05.1A Panel 4 / B04 04 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 05
ETC 2 B 05.1J Panel 4 / B05 05 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 06
ETC 2 B 05.1R Panel 4 / B06 06 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 07
ETC 2 B 05.1Z Panel 4 / B07 07 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 08
ETC 0 B 06.1A Panel 4 / B08 08 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 09
ETC 0 B 06.1J Panel 4 / B09 09 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 10
ETC 0 B 06.1R Panel 4 / B10 10 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 11
ETC 0 B 06.1Z Panel 4 / B11 11 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 12
ETC 2 B 06.1A Panel 4 / B12 12 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 13
ETC 2 B 06.1J Panel 4 / B13 13 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 14
ETC 2 B 06.1R Panel 4 / B14 14 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 15
ETC 2 B 06.1Z Panel 4 / B15 15 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 16
ETC 0 B 07.1A Panel 4 / B16 16 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 01
ETC 0 B 07.1J Panel 4 / B17 17 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 02
ETC 0 B 07.1R Panel 4 / B18 18 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 03
ETC 0 B 07.1Z Panel 4 / B19 19 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 04
ETC 2 B 07.1A Panel 4 / B20 20 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 05
ETC 2 B 07.1J Panel 4 / B21 21 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 06
ETC 2 B 07.1R Panel 4 / B22 22 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 07
ETC 2 B 07.1Z Panel 4 / B23 23 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 08
ETC 0 B 08.1A Panel 4 / B24 24 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 09
ETC 0 B 08.1J Panel 4 / B25 25 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 10
ETC 0 B 08.1R Panel 4 / B26 26 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 11
ETC 0 B 08.1Z Panel 4 / B27 27 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 12
ETC 2 B 08.1A Panel 4 / B28 28 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 13
ETC 2 B 08.1J Panel 4 / B29 29 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 14
ETC 2 B 08.1R Panel 4 / B30 30 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 15
ETC 2 B 08.1Z Panel 4 / B31 31 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 16
ETC car-tridge
From GT4C-A connector position
To panel / connector position
Multicoaxial front ports in CPETC-F panel through this cable
Coaxial insert pairs of the Multicoaxial front ports used by
Table 39 Unbalanced panels in cabling cabinet - A-interface (Cont.)
90 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d8058049ecb0
E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F)
5.3.2 TCSM3i for combined BSC/TCSM installation optionThe cabling cabinet is not used with the TCSA cabinet in the TCSM3i for combined BSC/TCSM installation option. Instead, the optical cabling from the front connectors of the ETS2 plug-in units is routed out of the cabinet through the CPGO at the cabinet top.
From car-tridge
TR3 unit slot From ET16 slot and con-nector position
ET panel / front ports through this cable
TC2C 0 01, 02, 03, 04 B 17.1A Panel 4 / 32 (4*ET)
TC2C 0 05, 06, 07, 08 B 17.1J Panel 4 / 33 (4*ET)
TC2C 0 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 34 (4*ET)
TC2C 0 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 35 (4*ET)
TC2C 1 01, 02, 03, 04 B 17.1A Panel 4 / 36 (4*ET)
TC2C 1 05, 06, 07, 08 B 17.1J Panel 4 / 37 (4*ET)
TC2C 1 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 38 (4*ET)
TC2C 1 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 39 (4*ET)
TC2C 2 01, 02, 03, 04 B 17.1A Panel 4 / 40 (4*ET)
TC2C 2 05, 06, 07, 08 B 17.1J Panel 4 / 41 (4*ET)
TC2C 2 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 42 (4*ET)
TC2C 2 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 43 (4*ET)
TC2C 3 01, 02, 03, 04 B 17.1A Panel 4 / 44 (4*ET)
TC2C 3 05, 06, 07, 08 B 17.1J Panel 4 / 45 (4*ET)
TC2C 3 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 46 (4*ET)
TC2C 3 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 47 (4*ET)
TC2C 4 01, 02, 03, 04 B 17.1A Panel 4 / 48 (4*ET)
TC2C 4 05, 06, 07, 08 B 17.1J Panel 4 / 49 (4*ET)
TC2C 4 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 50 (4*ET)
TC2C 4 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 51 (4*ET)
TC2C 5 01, 02, 03, 04 B 17.1A Panel 4 / 52 (4*ET)
TC2C 5 05, 06, 07, 08 B 17.1J Panel 4 / 53 (4*ET)
TC2C 5 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 54 (4*ET)
TC2C 5 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 55 (4*ET)
Notes
*) Connector positions B 17.1R and B 17.1Z are default positions when the TC2C cartridge is used for transcoder connections of one BSC.
Connector positions B 18.1A and B 18.1J are in use when the TC2C cartridge is used for transcoder connections of two BSCs (one half of the TC2C cartridge for one BSC and the other half for the other BSC).
Table 40 Unbalanced panels in cabling cabinet - Ater-interface
DN70617303Issue 1-0
91
Connector Panels and External Cables in Flexi BSC and TCSM3i
Roof panel with LAN, LPT/VDU, and synchronisationand alarm interfaces (CPRJ45-A)
Id:0900d805804ab823
6 Roof panel with LAN, LPT/VDU, and synchro-nisation and alarm interfaces (CPRJ45-A)The CPRJ45-A panel is located in the middle hole at the BSCC cabinet top and it can be installed without the RACP adapter. The CPRJ45-A provides interfaces for 100 Mbit/s and 1 Gbit/s LAN uplinks, LPTs and VDUs, incoming external synchronisation signals, and inputs and outputs for external alarms.
Figure 20 Panel CPRJ45-A with LAN, alarm, LPT/VDU, and synchronisation inter-faces - seen from the front of the cabinet
The various interfaces are presented in the following sections:
• LAN interfaces • External alarm cabling • LPT/VDU interfaces • External synchronisation cabling
6.1 LAN interfacesBoth 1000Base-Sx LAN interfaces (ports 04 to 07, 12 to 15) for 1 Gbit/s uplinks and 10/100/1000Base-T/Tx LAN interfaces (ports 00 to 03, 08 to 11) for 10/100 Mbit/s and 1 Gbit/s copper uplinks in CPRJ45-A panel are used.
For more information, see
• 1 Gbit/s optical uplink LAN cables
LAN INTERFACES
LPT/VDU INTERFACESEXT SYNC ININTERFACES EXT AL INTERFACES
DN0626528
06 07
14 15
00
Tx Rx Tx Rx
01
08 09
02
10
03
11
18 19
22 23
ASYMM 1CLS 0,1
28
ASYMM 0CLS 0,1
20
EXT AL OUTPUT
CURRENT-CONTROLLEDAL INPUTS
LPT 0 VDU 0SYMM 0CLS 0, 1
VDU 1 VDU 2 VDU 2 LPT 2
B A
10/100/1000Base-T/Tx uplinks 1000Base-Sx uplinks
16
(V.24)
17
(V.24)
24
(V.24)
27
(V.11)
Tx RxTx Rx
Tx Rx Tx RxTx RxTx Rx
12 13
0504
24
(V.24)
26
(V.11)
SYMM 1CLS 0, 1
EXT AL INPUT
21
CL
AS
S1
LA
SE
RP
RO
DU
CT
IEC
/EN
60825
-1
92 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804ab823
Roof panel with LAN, LPT/VDU, and synchronisation and alarm interfaces (CPRJ45-A)
• 10/100 Mbit/s / 1 Gbit/s copper uplink LAN cables
6.1.1 1 Gbit/s optical uplink LAN cablesThe Duplex LC connectors (04-07 and 12-15) in the connector panel CPRJ45-A are reserved for 1 Gbit/s optical uplink LAN cables. The optical uplink LAN interfaces in the CPRJ45-A panel are cabled to the front connectors of Ethernet Switch plug-in units using CLCS cables.
The following figure presents optical LC connectors.
Figure 21 Optical LC connectors, straight type
The following table presents the main characteristics of the optical cables and connec-tors.
The cables and the connectors should meet the requirements of the UL 1459 standard or the National Electrical Code ANSI/NFPA No.70 and the requirements of the FCC Part 68.
6.1.2 10/100 Mbit/s / 1 Gbit/s copper uplink LAN cablesThe RJ45 connectors (00 to 03 and 08 to 11) in the connector panel CPRJ45-A are reserved for 10/100 Mbit/s / 1 Gbit/s copper uplink LAN cabling. The uplink LAN inter-faces in the CPRJ45-A panel are cabled to the front connectors of Ethernet Switch plug-in units.
The cable types available for external 10/100 Mbits/1Gbits uplink cabling are the follow-ing:
• CNIX (cross-connected cable); connector type RJ45 modular connector (8-pole) • CNI (straight-connected cable); connector type RJ45 modular connector (8-pole)
The pin configuration in 10/100 Mbit/s use of the CNIX cable connector is presented in the following table.
Fibre cable mate-rial:
62.5/125 µm multimode fibre
Straight connec-tors:
Duplex LC, according to GR-326 , IEC 60874
30 5
DN70631285
Dustcaps to LCconnectors
B
Connector 1 Connector 2
Signal at CPRJ45
Colour Remarks
1 3 TX+ Orange/White Transmit (Tx)
2 6 TX- Orange Transmit (Tx)
Table 41 CNIX cable connector, pin configuration in 10/100 Mbit/s use (cross-con-nected cable)
DN70617303Issue 1-0
93
Connector Panels and External Cables in Flexi BSC and TCSM3i
Roof panel with LAN, LPT/VDU, and synchronisationand alarm interfaces (CPRJ45-A)
Id:0900d805804ab823
The pin configuration in 1 Gbit/s use of the CNIX cable connector is presented in the fol-lowing table.
The pin configuration in 10/100 Mbit/s use of the CNI cable connector is presented in the following table.
3 1 RX+ White/Green Receive (Rx)
6 2 RX- Green Receive (Rx)
4 7 Blue
5 8 White/Blue
7 4 White/Brown
8 5 Brown
Connector 1
Connector 2
Signal at CPRJ45
Colour Remarks
1 3 BI_DA+ Orange/White Transmit (Tx)
2 6 BI_DA- Orange Transmit (Tx)
3 1 BI_DB+ White/Green Receive (Rx)
6 2 BI_DB- Green Receive (Rx)
4 7 BI_DC+ Blue
5 8 BI_DC- White/Blue
7 4 BI_DD+ White/Brown
8 5 BI_DD- Brown
Table 42 CNIX cable connector, pin configuration in 1 Gbit/s use (cross-connected cable)
Connector 1, 2 Signal at CPRJ45-A
Colour Remarks
1 RX+ Orange/White Receive positive (Rx)
2 RX- Orange Receive negative (Rx)
3 TX+ White/Green Transmit positive (Tx)
4 Blue
5 White/Blue
Table 43 CNI cable connector, pin configuration in 10/100 Mbit/s use (straight-con-nected cable)
Connector 1 Connector 2
Signal at CPRJ45
Colour Remarks
Table 41 CNIX cable connector, pin configuration in 10/100 Mbit/s use (cross-con-nected cable) (Cont.)
94 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804ab823
Roof panel with LAN, LPT/VDU, and synchronisation and alarm interfaces (CPRJ45-A)
The pin configuration in 1 Gbit/s use of the CNI cable connector is presented in the fol-lowing table.
The main characteristics of 10/100 Mbit/s /1 Gbit/s copper LAN cables are presented in the following table.
The LAN interfaces complying with the IEEE 802.3 standard for Ethernet serial inter-faces are of 10 Base-T and 100 Base-TX.
For more information, see Requirement specifications for external cables of M98 mechanics BSC3i and TCSM3i equipment.
6 TX- Green Transmit negative (Tx)
7 White/Brown
8 Brown
Connector 1, 2 Signal at CPRJ45-A
Colour Remarks
1 BI_DB+ Orange/White Bi-rectional positive
2 BI_DB- Orange Bi-rectional negative
3 BI_DA+ White/Green Bi-rectional positive
4 BI_DD+ Blue Bi-rectional positive
5 BI_DD- White/Blue Bi-rectional negative
6 BI_DA- Green Bi-rectional negative
7 BI_DC+ White/Brown Bi-rectional positive
8 BI_DC- Brown Bi-rectional negative
Table 44 CNI cable connector, pin configuration in 1 Gbit/s use (straight-connected cable)
Cable type: 4 pairs, twisted, shielded (S-FTP), Cat. 5 E or better, AWG24/26
Cable connector: Shielded RJ45 modular connector (8-pole), Cat. 5 E or better
Table 45 Recommended cable types for LAN cables (CNI and CNIX)
Connector 1, 2 Signal at CPRJ45-A
Colour Remarks
Table 43 CNI cable connector, pin configuration in 10/100 Mbit/s use (straight-con-nected cable) (Cont.)
DN70617303Issue 1-0
95
Connector Panels and External Cables in Flexi BSC and TCSM3i
Roof panel with LAN, LPT/VDU, and synchronisationand alarm interfaces (CPRJ45-A)
Id:0900d805804ab823
6.2 External alarm cablingThe CPRJ45-A panel accommodates two D25 connectors, one (21) for external alarm inputs and one (22) for external alarm outputs. There is also one D9 connector (23) for voltage and current-controlled alarm inputs. The CPRJ45-A is located in the middle hole at the equipment cabinet top.
The external alarm cabling connectors are shown in the following table.
External alarm output signals - CNDE cableExternal Alarm output signals at the CPRJ45-A panel and configurations of CNDE cable with D25 connectors are presented in the following table.
Connector Cable, Connector Cable type
21 CYR, 25-pin D-connector, male. Other end has no connector
Milliflex3 SH AWG26/15 pairs
22 CNDE, two 25-pin D-connec-tors, male. Other end only par-tially connected
Milliflex3 SH AWG26/15 pairs
23 CYV 9-pin D-connector, male. Other end has no connector
Milliflex3 SH AWG26/8 pairs
Table 46 External alarm cabling connectors in the CPRJ45-A panel
Pin Alarms CNDE CNDE CNDC
CPRJ45-A panel, connec-tor 22
Connector 22 (EXT AL OUTPUT
Connector 1 Colour Connector 2
1 AEO0 1 Blue/White 1 (EXAU-A)
2 AEO1 2 White/Blue 3 (EXAU-A)
3 AEO2 3 Orange/White
5 (EXAU-A)
4 AEO3 4 White/Orange
7 (EXAU-A)
5 AEO4 5 Green/White 9 (EXAU-A)
6 AEO5 6 White/Green 11 (EXAU-A)
7 AEO6 7 Brown/White 13 (EXAU-A)
8 AEO7 8 White/Brown 15 (EXAU-A)
9 AEO8 9 Grey/White 17 (EXAU-A)
10 AEO9 10 White/Grey 19 (EXAU-A)
11 AE10 11 Blue/Yellow 21 (EXAU-A)
12 AE11 12 Yellow/Blue 23 (EXAU-A)
13 AE12 13 Orange/Yel-low
nc
Table 47 Alarm signals at the CPRJ45-A panel and pin configuration of CNDE cable with D25 connectors
96 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804ab823
Roof panel with LAN, LPT/VDU, and synchronisation and alarm interfaces (CPRJ45-A)
Alarms AEO0-AEO11 are connected directly to the EXAU-A with cable CNDE. All alarms AEO0-AEO15 can be connected to the cross connection (DDF) with cable CNDE (the other cable end, connector 2, cut off).
Four lengths of CNDE cable are available (ID codes presented):
• 5 m: C106809 • 10 m: C106819 • 20 m: C108435
14 AE13 14 Yel-low/Orange
nc
15 AE14 15 Green/Yellow nc
16 AE15 16 Yellow/Green nc
17 - 17 Brow/Yellow nc
18 - 18 Yellow/Brown nc
19 - 19 Grey/Yellow nc
20 - 20 Yellow/Grey nc
21 - 21 Blue/Violet nc
22 - 22 Violet/Blue nc
23 - 23 Orange/Vio-let
nc
24 - 24 Vio-let/Orange
nc
25 GND 25 Green/Violet 2, 4, 6, 8, 10, 12, 14, 16, 18, 20, 22, 24, 25
- - nc Violet/Green nc
- - nc Brow/Violet nc
- - nc Violet/Brown nc
- - nc Grey/Violet nc
- - nc Violet/Grey nc
- - 25 Connector hood
Screen wire Connector hood
Hood GND Connector hood
Cable shield Connector hood
Notes
AEO = External alarm output signal
GND = Ground signal
Pin Alarms CNDE CNDE CNDC
CPRJ45-A panel, connec-tor 22
Connector 22 (EXT AL OUTPUT
Connector 1 Colour Connector 2
Table 47 Alarm signals at the CPRJ45-A panel and pin configuration of CNDE cable with D25 connectors (Cont.)
DN70617303Issue 1-0
97
Connector Panels and External Cables in Flexi BSC and TCSM3i
Roof panel with LAN, LPT/VDU, and synchronisationand alarm interfaces (CPRJ45-A)
Id:0900d805804ab823
• 50 m: C107185
Voltage controlled external alarm inputs - alarm cable CYR
Pin; Alarms; Alarm cable CYR;
Alarm cable CYR;
CPRJ45-A panel, connec-tor 21
Connector 21 (Voltage and current-controlled EXT AL INPUT)
Pin in Connector 1
Colour
1 AEI0 1 Blue/White
2 AEI1 2 White/Blue
3 AEI2 3 Orange/White
4 AEI3 4 White/Orange
5 AEI4 5 Green/White
6 AEI5 6 White/Green
7 AEI6 7 Brown/White
8 AEI7 8 White/Brown
9 AEI8 9 Grey/White
10 AEI9 10 White/Grey
11 AEI10 11 Blue/Yellow
12 AEI11 12 Yellow/Blue
13 AEI12 13 Orange/Yellow
14 AEI13 14 Yellow/Orange
15 AEI14 15 Green/Yellow
16 AEI15 16 Yellow/Green
17 AEI16 17 Brown/Yellow
18 AEI17 18 Yellow/Brown
19 AEI18 19 Grey/Yellow
20 AEI19 20 Yellow/Grey
21 AEI20 21 Blue/Purple
22 AEI21 22 Purple/Blue
23 AEI22 23 Orange/Purple
24 AEI23 24 Purple/Orange
25 GND 25 Green/Violet
- - nc Violet/Green
- - nc Brown/Violet
- - nc Violet/Brown
- - nc Grey/Violet
Table 48 Signals on panel connector 21 (Voltage and current-controlled AL inputs, AEIx)
98 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804ab823
Roof panel with LAN, LPT/VDU, and synchronisation and alarm interfaces (CPRJ45-A)
Voltage controlled external alarm input signals are connected from MDF to CPRJ45-A panel using CYR cable. Three lengths are available (CS codes presented):
• 35 m: CS73131.35 • 50 m: CS73131.50 • 70 m: CS73131.70
24 external voltage controlled alarm inputs can be connected to Flexi BSC using the CYR cable.
Current-controlled external alarm inputs
- - nc Violet/Grey
- - 25 Connector hood
Screen wire
Hood GND Connector hood Cable shield
Note
AEI = Voltage controlled external alarm input signal
Pin; Alarms; Alarm cable CYV;
Alarm cable CYV;
CPRJ45-A panel, connec-tor 23
Connector 23 (Voltage and current-controlled EXT AL INPUT)
Pin in Connector 1
Colour
1 ALS0 1 Blue/White
2 ALS1 2 White/Blue
3 ALS2 3 Orange/White
4 ALS3 4 White/Orange
5 ALS4 5 Green/White
6 ALS5 6 White/Green
7 - 7 Brown/White
8 - 8 White/Brown
9 GND 9 Grey/White
- - nc White/Grey
- - nc Blue/Yellow
Table 49 Signals on panel connector 23 (current-controlled ALS inputs)
Pin; Alarms; Alarm cable CYR;
Alarm cable CYR;
CPRJ45-A panel, connec-tor 21
Connector 21 (Voltage and current-controlled EXT AL INPUT)
Pin in Connector 1
Colour
Table 48 Signals on panel connector 21 (Voltage and current-controlled AL inputs, AEIx) (Cont.)
DN70617303Issue 1-0
99
Connector Panels and External Cables in Flexi BSC and TCSM3i
Roof panel with LAN, LPT/VDU, and synchronisationand alarm interfaces (CPRJ45-A)
Id:0900d805804ab823
Current-controlled external alarm input signals are connected from MDF to CPRJ45-A panel by using the CYV cable.
One length of the cable is available (ID code presented): 20 m (C72239).
Six external current-controlled alarm inputs can be connected to the Flexi BSC by using the CYV cable.
Connections to external alarm unit EXAU-AA special lamp panel (External Alarm Unit EXAU-A) can be employed for the indication of alarms.
Indicator lights have been connected to six incoming alarms of EXAU-A. In the EXAU-A, a buzzer that can be connected to any alarm is available.
Using CNDE cable, the EXAU-A can be directly connected to D25-connector 22 of the CPRJ45-A panel or through the digital distribution frame (DDF or cross connection) that connects the alarm cables coming from the network element. When the alarms are routed through the digital distribution frame (DDF) the CNDE cable is cut and the wires are connected to the cross connection.
The complete CNDE cable is available in lengths 5, 10, 20 and 50 m. The maximum distance between the EXAU-A panel and the network element equipment it is connected to is 200 m (650ft.).
General requirements for external alarm cable CNDE are presented in the following table.
- - nc Yellow/Blue
- - nc Orange/Yellow
- - nc Yellow/Orange
- - nc Green/Yellow
- - nc Yellow/Green
- - 9 Connector hood Screen wire
Hood GND Connector hood Cable shield
Note
ALS = current-controlled external alarm input signal
Cable type: 12 pairs, twisted, shielded, cross section 0.4 mm2, Milliflex3 SH AWG26/8 pairs
Cable connector: 25-pin D connector (male/female)
Table 50 General requirements for external alarm cable CNDE
Pin; Alarms; Alarm cable CYV;
Alarm cable CYV;
CPRJ45-A panel, connec-tor 23
Connector 23 (Voltage and current-controlled EXT AL INPUT)
Pin in Connector 1
Colour
Table 49 Signals on panel connector 23 (current-controlled ALS inputs) (Cont.)
100 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804ab823
Roof panel with LAN, LPT/VDU, and synchronisation and alarm interfaces (CPRJ45-A)
The EXAU-A has also a second D25 connector which makes is possible to chain several alarm units so that the alarms can be displayed on more than one unit. See figure Instal-lation of the EXAU-A; mounting on the wall, cabling, and setting the buzzer jumpers.
Figure 22 Installation of the EXAU-A; mounting on the wall, cabling, and setting the buzzer jumpers
The colours of the alarm signals are shown in the following table.
Colour Position Signal Alarm
Red (1) Uppermost (AL00) Alarm 1
Yellow (2) (AL01) Alarm 2
Green (3) (AL02) Alarm 3
Red (4) (AL03) Alarm 4
Yellow (5) (AL04) Alarm 5
Blue (6) Lowermost (AL05) Alarm 6
140
134
DN068749
CAUTION 48V
J1
GND
1AL00 -
2AL01 -
3AL02 -
4AL03 -
5AL04 -
6AL05 -
7
8
ON
BUZZER SELECTSW1
Alarm 1AL00Alarm 2AL01Alarm 3AL02Alarm 4AL03Alarm 5AL04Alarm 6AL05 Test
Buzzer Reset
Silent Mode
2
3
3
2
5
SW1
J1F1
SW2
LS1
4
1
6
Base
PCB
PCB
Cover
DN70617303Issue 1-0
101
Connector Panels and External Cables in Flexi BSC and TCSM3i
Roof panel with LAN, LPT/VDU, and synchronisationand alarm interfaces (CPRJ45-A)
Id:0900d805804ab823
6.3 VDU/LPT peripheral cabling (LPT/VDU interfaces)The CPRJ45-A panel accommodates six RJ45 connectors for the following VDU and LPT interfaces:
• port 16 for LPT 0 (V.24) • port 17 for VDU 0 (V.24) • ports 24 and 25 for VDU1 (V.24) and VDU2 (V.24) • ports 26 and 27 for VDU2 (V.11) and LPT2 (V.11).
Each connector provides access to one interface of visual display unit / PC or printer provided by the OMU (SERO-B). Pin configurations for connectors (16 and 17, and 24 to 27) providing the VDU/LPT interfaces are listed in Table V.24/V.11 cable connector in the CPRJ45-A panel, pin configuration.
The VDU can be connected to the CPRJ45-A panel by using the CNM cable, which is a CNI-type cable provided with an RJ45 connector and a D9 connector. The LPT printer can be connected to the CPRJ45-A panel using the CNP cable, which is a CNI-type cable provided with an RJ45 connector and a D25 connector. See the following figure.
Pin Signal (V.24) Signal (V.11) Colour
1 DTR TxD+ Orange/White
2 TxD TxD- White/Orange
3 GND RxD+ Green/White
4 GND Blue/White
5 RxD White/Blue
6 DSR RxD- Green/White
7 CTS Brown/White
8 RTS White/Brown
Table 51 V.24/V.11 cable connector in the CPRJ45-A panel, pin configuration
102 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804ab823
Roof panel with LAN, LPT/VDU, and synchronisation and alarm interfaces (CPRJ45-A)
Figure 23 Peripheral cables; CNM for VDU and CNP for LPT
Recommended cable types for V.24/V.11 cables (CNI) are shown in the following table.
The cable and the connector meet the requirements of the UL 1459 standard or the National Electrical Code ANSI/NFPA No.70. The connector also meets the require-ments of the FCC Part 68.
Pos. numberConn. RJ45F
Pos. numberConn. DB25M
Wire colour
1 (DTR)
2 (TxD)
3 (GND)
4 (GND)
5 (RxD)
6 (DSR)
7 (CTS)
8 (RTS)
6 (DSR)
3 (RxD)
2 (TxD)
20 (DTR)
4 (RTS)
5 (CTS)
Conn. hood Conn. hood
Pos. numberConn. RJ45F
Pos. numberConn. DE9FWire colour
1 (DTR)
2 (TxD)
3 (GND)
4 (GND)
5 (RxD)
6 (DSR)
7 (CTS)
8 (RTS)
orange/white
orange
blue
white/blue
green
white/brown
brown
6 (DSR)
2 RxD
3 (TxD)
4 (DTR)
7 (RTS)
8 (CTS)
Conn. hood shield Conn. hood
white/green
orange/white
orange
blue
white/blue
green
white/brown
brown
shield
white/green
1 (GND)1 (GND)
5 (signal GND) 7 (signal GND)
DN02237579
A
A
C
C
VIEW A-A
RJ45F(female)
VIEW C-C
RJ45F(female)
CMN-cable
CNP-cable
L
L
12
1DE9F
(female)
VIEW B-B
BB
DB25M(male)
32
1 1
2
3
POSITION NUMBER 1
UNC-40 male locking screws
USE CABLE OUTLETOPTIMISING BUSHING
VIEW D-D
1
D D
CONNECTION CNM-cable CONNECTION CNP-cable
Cable type 4 pairs, twisted, shielded (S-FTP), Cat. 5 E, AWG24/26
Cable connector Shielded RJ45 modular connector (8-pole), Cat. 5 E.
Table 52 Recommended cable types for V.24/V.11 cables (CNI)
DN70617303Issue 1-0
103
Connector Panels and External Cables in Flexi BSC and TCSM3i
Roof panel with LAN, LPT/VDU, and synchronisationand alarm interfaces (CPRJ45-A)
Id:0900d805804ab823
6.4 External synchronisation cabling (EXT SYNC interfaces)The CPRJ45-A panel accommodates two RJ45 connectors (18 SYMM0 and 19 SYMM1) for balanced (symmetric) synchronisation interfaces, and two BNC connectors (20 ASYMM0 and 28 ASYMM1) for coaxial, unbalanced interfaces.
Balanced (symmetric)The pin configuration for connectors 18 (SYMM0 CLS 0,1) and 19 (SYMM1 CLS 0,1), and colours for CNI cable connector are presented in the following table.
Recommended cable types for balanced synchronisation cable (CNI) are shown in the following table.
Pin Connector 18 (SYMM0CLS 0,1)
Connector 19 (SYMM1CLS 0,1)
Colour (CNI) Remarks
1 FS1A FS2A Orange/White Wire A of external fre-quency standard FS1 or FS2
2 FS1B FS2B White/Orange Wire B of external fre-quency standard FS1 or FS2
3 - - Green/White
Blue/White
White/Blue
Green/White
7 - - Brown/White
8 - - White/Brown
Connector hood
RSG1 RSG2 Ground signal
Notes
FS1A = Wire A of external frequency standard FS1
FS1B = Wire B of external frequency standard FS1
FS2A = Wire A of external frequency standard FS2
FS2B = Wire B of external frequency standard FS2
RSG1 = Ground signal
RSG2 = Ground signal
Table 53 The pin configuration for connectors 18 and 19
Cable type: 4 pairs, twisted, shielded (S-FTP), Cat. 5 E, AWG24/26
Cable connector: Shielded RJ45 modular connector (8-pole), Cat. 5 E.
Table 54 Recommended cable types for synchronisation cables (CNI)
104 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804ab823
Roof panel with LAN, LPT/VDU, and synchronisation and alarm interfaces (CPRJ45-A)
Unbalanced (asymmetric)The pin configuration for connectors 20 and 28 is shown in the following table.
Pin Signal / Connector 20 / ASYMM0 CLS0,1
Signal / Connector 28 / ASYMM1 CLS0,1
Centre wire FS1A FS2A
Cable sheath FS1B FS2B
Table 55 Pin configuration for connectors 20 and 28
DN70617303Issue 1-0
105
Connector Panels and External Cables in Flexi BSC and TCSM3i
Cabling panel with grounding outlets (CPGO)
Id:0900d8058048f55e
7 Cabling panel with grounding outlets (CPGO)The cabling panel with grounding outlets (CPGO) is installed at site at the BSCC cabinet top of the Flexi BSC. The CPGO is used for STM-1/OC-3 trunk cables and GigE Ethernet interface cables.
Figure 24 CPGO
The cables and the connectors meet the requirements of the UL 1459 standard or the National Electrical Code ANSI/NFPA No.70 as well as the requirements of the FCC Part 68.
Figure 25 Optical LC connectors, straight type
Main characteristics of optical cables and connectors are shown in the following tables.
For more information on the optical cables, see Requirement specifications for external cables of M98 mechanics Flexi BSC product family and TCSM3i.
Fibre cable material: 9/125 um singlemode fibre
Straight or angle connectors: Duplex LC, according to GR-326, IEC 60874
Table 56 Main characteristics of optical singlemode cables and connectors
Fibre cable material: 62.5/125 um multimode fibre
Straight or angle connectors: Duplex LC, according to GR-326, IEC 60874
Table 57 Main characteristics of optical multimode cables and connectors
CPGO
DN0626582
30 5
DN70631285
Dustcaps to LCconnectors
B
106 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804f3fcb
Requirement specifications for external cables of M98 mechanics Flexi BSC and TCSM3i
8 Requirement specifications for external cables of M98 mechanics Flexi BSC and TCSM3i
8.1 General requirements for connectors and cable materialsConnectors:
• Connectors and hoods of the connectors must be shielded • 1.25 mm, or 50 microinches (0.75 mm or 30 microinches, if 1.25 mm is not available)
gold plating on the contacts • UL94 V-0 materials
Cable material:
• Shielded construction, screening effectiveness > 60 dB at 1GHz • AWG 26 conductors • Continuous pair twisting on the twisted pair cables • Operating temperature 0 to 80°C • VW-1 materials
Optional:
• Halogen free materials (IEC 332-1 or IEC 332-3) • Grey colour (RAL 7036, if available)
8.2 Requirements for specified coaxial cable assemblies
8.2.1 E1 coaxial unbalanced PCM cable assembly
Cable:
• Multicoaxial cable (8 coax) with common braid • Impedance 75 ± 3 Ω • Maximum attenuation < 9dB/100 m at 10 MHz • Nominal capacitance: < 66 pF/m • Conductor resistance: < 365 Ω/km
Connectors:
• Coaxial connectors: SMB/50 Ω/straight type
8.2.2 Unbalanced (coaxial) external synchronisation cable assembly (CKB)
Cable:
• Coaxial (BT 3002) • Impedance 75 Ω ± 4 Ω • Attenuation: 4.4 dB/100 m at 5 MHz
DN70617303Issue 1-0
107
Connector Panels and External Cables in Flexi BSC and TCSM3i
Requirement specifications for external cables of M98mechanics Flexi BSC and TCSM3i
Id:0900d805804f3fcb
• Capacitance: < 66 pF/m
Connectors:
• BNC type
8.3 Requirements for specified twisted pair cable assemblies
8.3.1 10 Base-T /100 Base-TX / 1000Base-T/TX LAN cable assemblies (CNI and cross-connected LAN cable)
Cable:
• S-FTP • Category 5 E • Meets EIA/TIA 568-A standard
Connectors:
• RJ45
8.3.2 T1 (E1) balanced PCM cable assembly (CNIS)
Cable:
• Nominal impedance: 100 ± 15 Ω • Attenuation: < 4 dB/100 m at 1 MHz • Resistance: Maximum 151 Ω/km at 20°C • Crosstalk attenuation: > 70 dB at 150 kHz
Connectors:
• Shielded 8-pole plug RJ45
8.3.3 E1 balanced PCM cable assembly (CNIB)
Cable:
• Nominal impedance: 120 ± 15 Ω • Attenuation: < 4 dB/100 m at 1 MHz • Resistance: Maximum 151 Ω/km at 20°C • Crosstalk attenuation: > 70 dB at 150 kHz
Connectors:
• Shielded 8-pole plug RJ45
8.3.4 E1 balanced PCM cable assembly (CNIA)
Cable:
• Nominal impedance: 120 ± 15 Ω • Attenuation: < 4 dB/100 m at 1 MHz • Resistance: Maximum 151 Ω/km at 20°C
108 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804f3fcb
Requirement specifications for external cables of M98 mechanics Flexi BSC and TCSM3i
• Crosstalk attenuation: > 70 dB at 150 kHz
Connectors:
• Shielded 8-pole plug RJ45
8.3.5 Current and voltage-controlled alarm cable assembly (CNDC)
Cable:
• See General requirements
Connectors:
• 25-pin D-subminiature connector at both ends of the cable
8.3.6 Alarm cable (CNDE)
Cable:
• 10-pair • double shielded (foil and copper braid) • halogen-free jacket • differential impedance 100 Ω • AWG 26 conductors
Connectors:
• 25-pole male D-connectors
8.3.7 Alarm cable (CYV)
Cable:
• Milliflex3 SH AWG26/4 pairs
Connectors:
• male 9-pin D-connector at one end of the cable
8.3.8 Alarm cable (CYR)
Cable:
• See General requirements
Connectors:
• 25-pin D-subminiature connector at one end of the cable
8.3.9 Electrical performance requirements for X.25 cable assemblies
Cable:
• Linear resistance of the conductor: 151 Ω/km, maximum 20 °C • Nominal impedance: 100 ± 15 Ω • Attenuation: < 4 dB/100 m at 1 MHz
DN70617303Issue 1-0
109
Connector Panels and External Cables in Flexi BSC and TCSM3i
Requirement specifications for external cables of M98mechanics Flexi BSC and TCSM3i
Id:0900d805804f3fcb
• Capacitance between cores: 60 pF/m nominal • Phase delay time: 5.4 ms/km at 1 MHz • Crosstalk attenuation: > 50 dB at 150 kHz
V.24 cable assemblies (CLSC)Connectors:
• 25-pin D-subminiature connector • 2HM connector
V.35 cable assembly (CLRD) - S11.5Connectors:
• V.35 connector • D25 connector
V.35 cable assembly (CLRC)- S10 and S11Connectors:
• V.35 connector • 2HM connector
X.21 cable assemblies (CLTC)Connectors:
• 15-pin D-subminiature connector • 2 Hard Metric connector
8.3.10 Electrical performance requirements for optical LC cable assem-blies (multimode cable)
Fibre cable material
• 62,5/125 µm multi mode fibre • RoHS-compliance according to EU-directive • Attenuation 3.8 dB/km maximum at 850 nm wavelength, according to IEC 60793-1-
C1 • Duplex type • Halogen free material, according to IEC 60754-1 • Flammability UL VW-1 listed or UL94V-0 rated material • Fibre cables must be provided with a common secondary overall jacket, which is not
permitted to glide too loosely along fibre cables • Shape of cable jacket, circular, elliptical jacket can be used, if circular material is not
available • Cable outer diameter 6.6mm maximum • Minimum bending radius during installation 65 mm and in service 43mm, according
to IEC 60794-1-2E11A or similar standard • Crush resistance (briefly) > 500 N/cm, according to IEC 60794-1-E3
Crush resistance (continuous) > 100 N/cm • Orange jacket color, if orange is not available, gray color can be used • Operating temperature from 0 to 70°C
110 DN70617303Issue 1-0
Connector Panels and External Cables in Flexi BSCand TCSM3i
Id:0900d805804f3fcb
Requirement specifications for external cables of M98 mechanics Flexi BSC and TCSM3i
Connector 1 and connector 2
• TIA/EIA 604-10A • All requirements are for one connector • Duplex LC, according to GR-326 and IEC 60874 • RoHS-compliance according to EU-directive • Mating durability for 200 reconnects, insertion loss change < 0.2 dB • Insertion loss 0.5 dB maximum • SPC finish • Return loss > 20 dB • Flammability UL94V-0 • Zirconia ferrule • Beige color • Dust caps included • Operating temperature from 0 to 70°C • Efficiency of strain relief > 80N/termination
Cable support for LC connector 1
• Flammability UL94 V-0 • Straight flexible boot • RoHS-compliance according to EU-directive • Cable boot color gray/beige • Efficiency of strain relief > 50N/boot
Cable support for LC connector 2
• Flammability UL94 V-0 • 90° angle boot • RoHS-compliance according to EU-directive • Maximum installation length 70 mm • Cable boot color gray/beige • Efficiency of strain relief: > 20N/boot • Design should allow rotation of cable support
8.3.11 Electrical performance requirements for optical LC cable assem-blies (singlemode cable)
Cable material:
• 9/125 µm single mode fibre • RoHS-compliance according to EU-directive • Cut-off wavelength < 1260 nm, according to IEC 60793-1-C7B • Attenuation (buffered fiber):
= 0,50 dB/km at 1310 nm wavelengths, according to IEC 60793-1-C10 = 0,40 dB/km at 1550 nm wavelengths, according to IEC 60793-1-C10
• Cable must fulfill ITU-T G.652 for interface type STM-1 optical (ITU-T G.957, table 1) • Cable must fulfill ATM 155 Mb/s o Duplex type • Duplex type • Halogen free material, IEC 60754-1
DN70617303Issue 1-0
111
Connector Panels and External Cables in Flexi BSC and TCSM3i
Requirement specifications for external cables of M98mechanics Flexi BSC and TCSM3i
Id:0900d805804f3fcb
• Flammability UL VW-1 or UL94V-0 rated cable material • Fibre cables must be provided with a common secondary overall jacket, which is not
permitted to glide too loosely along fibre cables • Shape of cable jacket circular, elliptical jacket can be used, if the circular material is
not available • Cable outer diameter 6.6 mm maximum • Minimum bending radius during installation, 65 mm and in service 43 mm, according
to IEC 60794-1-2E11A or similar standard • Crush resistance (briefly) > 500 N/cm, according to IEC 60794-1-E3
Crush resistance (continuous) > 100 N/cm • Yellow jacket color • Operating temperature from 0 to 70°C
Connector 1 and connector 2
• All requirements are for one connector • Duplex LC, according to GR-326 and IEC 60874 • RoHS-compliance according to EU-directive • Mating durability for 200 reconnects, insertion loss change < 0.2 dB • Insertion loss < 0.3 dB • SPC finish • Return loss > 45 dB • Flammability UL94V-0 • Zirconia ferrule • Blue color • Dust caps included • Operating temperature from 0 to 70°C • Efficiency of strain relief > 80N
Cable supports for LC connector 1
• Flammability UL94V-0 • Straight flexible boot • RoHS-compliance according to EU-directive • Cable boot color gray/beige • Efficiency of strain relief > 50N/boot
Cable supports for LC connector 2
• Flammability UL94V-0 • 90° angle boot • RoHS-compliance according to EU-directive • Maximum installation length 70 mm • Cable boot color gray/beige • Efficiency of strain relief > 20N/boot • Design should allow rotation of cable support