Post on 15-Jul-2015
SD
1 PARTITION TYPE
GRAPHIC SYMBOLS
WALL MOUNTED SMOKE DETECTOR
EXHAUST VENT
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE REMOVED
NEW CONSTRUCTION
EX
G 6
" V
EN
T. S
TA
CK
EX
G 4
" S
OIL
ST
AC
K
3"2"
RELOCATEW/C
2"
RELOCATELAV
1 1/
2"
BATH 2 POWDER ROOM
4"CO.
4"CO.
3" 2"
RELOCATEW/C
2"
RELOCATELAV
1 1/2"
3"
1 1/
2"
RELOCATESHOWER
MASTER BATH
3"1-1/2"
RELOCATEW/C
2"
RELOCATELAV
1 1/
2"
4"CO.
3"
1 1/
2"
RELOCATESHOWER
1-1/2"
REMOVELAV
1 1/
2"
REMOVEHOT TUB
2"
LAUNDRY
2"
FLOOR DRAIN
GREENHOUSE
EX
G 6
" V
EN
T. S
TA
CK
EX
G 4
" S
OIL
ST
AC
K
PH-F Upper Level
PH-F 36th Flr Main Level
CO.1-1/2"
1 1/
2" RELOCATESINK
KITCHEN
EXIST. HOUSE TRAP
RELOCATEDISHWASHER
CO.1-1/2"
1 1/
2" NEWSINK
GREENHOUSE
Roof
EAST 73RD STREET
37 STORY BUILDING#300BLOCK: 1448LOT: 3OCCUPANCY CLASS: RESCONSTRUCTION CLASS: 1
AREA OFWORK ON36TH FLOOR
ADJACENT 14 STORYBUILDING
ADJACENT 6 STORYBUILDING
100
102.
17
100100
102.
17
153.2551.08
100
51.08
100 25
25
25
EAST 74TH STREET
2ND
AV
EN
UE
NEIGHBORING 2 STORYBUILDING
M
GASMETER
CELLAR
3/4"
RELOCATEGAS RANGE
EXISTINGGAS RISER
APT. 5E
KITCHEN
EXISTINGGAS SHUT-OFFVALVE
36TH FLOOR
Push Side
42 minY
54 min
X24 preferred60 min18 min,
Pull Side
48 min
X Push Side
Pull Side
NOTE: All doors in alcoves shall comply with the clearances for front approaches.
12"
(FIG. 25)(FIG. 25)
Clearance of optional enclosure.
NOTE: Dashed line indicates dimensional
8 min Knee
6 max Toe
17 min Lavatory Depth
9 min
27 m
in
29 m
in
49 m
ax
19 max17 min
clear floor space
30 m
in
48 min
6 max
38 m
in
32 m
ax
24 min
38 m
in
32 m
ax
foot
areacontrol
24 min
6 m
ax38 m
in
48 min
back
6 max
seat
head
back wall side wall
38 m
in
38 m
in
12 min 12 min
32 m
ax
toilet paper
19 m
in
12 18 min
36 max
32 m
ax
clear floor space
18
lav.
min
36 min
56 m
in
48 min
min
clear floor space
lav.
1816-18
36 min
66 m
in
48 min
16-18
Clearance
Clearance
spacefloor
30 m
inclear
60 min
back
foot
head
18 m
in
B. Hinge Side Approaches - SwingingDoors
A. Front Approaches - Swinging Doors
NOTE: y = 48" minimum ifdoor has both a latchand closer.
NOTE: x = 36" minimum if y= 60"; x = 42" minimumif y = 54".
NOTE: x = 12" if doorhas both a closerand latch.
MANEUVERING CLEARANCES AT DOORSCLEAR FLOOR SPACE
AT BATHTUBREINFORCED AREAS FOR GRABS AT BATHTUB
CLEAR FLOOR SPACE AT WATER CLOSETREINFORCED AREAS FOR GRAB BARS AT WATER CLOSET CLEAR FLOOR SPACE AND CLEARANCES AT LAVATORIES
.
.
. .
Y.
.
. .
.
...
..
.
.
Scale:
ConsultantContactAddress
Phonee-mail
ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523
www.wilkinsonarchitects.com
New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561
National Council of Architectural Registration Board #52853
DOB Barcode
ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY 10001212.929.2491Ilya@atozengineers.com
ConsultantContactAddress
Phonee-mail
NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY 11372646-522-0589rhanna@engineer.com
MECHANICAL
STRUCTURAL
As indicated
A-000
GENERAL NOTES / PLOT PLAN
ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021
04/03/2015
BUILDING DEPT. GENERAL NOTES1. SCOPE OF WORK: APPLICATION FILED FOR THE INTERIOR RENOVATION OF EXISTING PENTHOUSE F. NOCHANGE IN USE, OCCUPANCY, OR EGRESS.
2. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE NEW YORK CITY BUILDING CODE, FIREDEPARTMENT REGULATIONS, UTILITY COMPANY REQUIREMENTS, AND THE BEST TRADE PRACTICES.
3. BEFORE COMMENCING WORK, THE CONTRACTOR SHALL FILE ALL REQUIRED CERTIFICATES OFINSURANCE WITH THE DEPARTMENT OF BUILDINGS, OBTAIN ALL REQUIRED PERMITS, AND PAY ALL FEESREQUIRED BY GOVERNING NEW YORK CITY AGENCIES.
4. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE FIELD PRIOR TO COMMENCING WORK,AND SHALL REPORT ANY DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS TO THEARCHITECT.
5. MINOR DETAILS NOT USUALLY SHOWN OR SPECIFIED, BUT NECESSARY FOR PROPER CONSTRUCTION OFANY PART OF THE WORK SHALL BE INCLUDED AS IF THEY WERE INDICATED IN THE DRAWINGS.
6. THE CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES WITH REQUIREMENTS OF LOCALAUTHORITIES AND BUILDING MANAGEMENT.
7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL CONDITIONS AND MATERIALSWITHIN THE PROPOSED CONSTRUCTION AREA. THE CONTRACTOR SHALL DESIGN AND INSTALL ADEQUATESHORING AND BRACING FOR ALL STRUCTURAL OR REMOVAL TASKS. THE CONTRACTOR SHALL HAVE SOLERESPONSIBILITY FOR ANY DAMAGE OR INJURIES CAUSED BY OR DURING THE EXECUTION OF THE WORK.
8. THE CONTRACTOR SHALL LAY OUT HIS OWN WORK, AND SHALL PROVIDE ALL DIMENSIONS REQUIRED FOROTHER TRADES (PLUMBING, ELECTRICAL, ETC.).
9. PLUMBING, HVAC, AND ELECTRICAL WORK SHALL BE PERFORMED BY PERSONS LICENSED IN THEIRTRADES, WHO SHALL ARRANGE FOR AND OBTAIN INSPECTIONS AND REQUIRED SIGN-OFFS.
10. THE CONTRACTOR SHALL DO ALL CUTTING, PATCHING, REPAIRING AS REQUIRED TO PERFORM ALL OFTHE WORK INDICATED ON THE DRAWINGS, AND ALL OTHER WORK THAT MAY BE REQUIRED TO COMPLETETHE JOB.
11. ALL PIPING AND WIRING SHALL BE REMOVED TO A POINT OF CONCEALMENT AND SHALL BE PROPERLYCAPPED OR PLUGGED.
12. THE CONTRACTOR, UPON COMPLETION OF THE WORK, SHALL ARRANGE FOR DEPARTMENT OFBUILDINGS INSPECTIONS AND SIGNOFFS AS REQUIRED
SMOKE/CARBON MONOXIDE DETECTIONDEVICES1. SMOKE/CARBON MONOXIDE DETECTORS OR DEVICES SHALL BE INSTALLED IN ORDINANCE WITH THEHOUSING MAINTENANCE CODE,MULTIPLE DWELLING LAW, THE NEW YORK CITY BUILDING CODE, AND THENEW YORK CITY ELECTRICAL CODE.
2. SMOKE DETECTORS AND CARBON MONOXIDE DETECTORS MAY BE COMBINED PROVIDING THE DEVICESCOMPLY WITH THE PROVISIONS OF TITLE OF THE ADMINISTRATIVE CODE OF THE CITY OF NEW YORK ANDANY APPLICABLE RULES PROMULGATED THEREUNDER.
3. EACH SMOKE/CARBON MONOXIDE DETECTOR SHALL BE INSTALLED IN ACCORDANCE WITH SECTION BC908.7.1 THROUGH 908.7.3.
4. EACH SMOKE/CARBON MONOXIDE DETECTOR SHALL BE INSTALLED OUTSIDE OF EACH SLEEPING ROOM INTHE IMMEDIATE VICINITY OR WITHIN 15'-0" OF THE ENTRANCE TO A SLEEPING ROOM.
5. EACH SMOKE CARBON MONOXIDE DETECTOR SHALL BE OF A TYPE THAT ALLOWS FOR READILY TESTINGOF SUCH DEVICE.
6. DUPLEX UNITS SHALL HAVE A DEVICE LOCATED ON EACH LEVEL IF ONLY ONE MEANS OF EGRESS ISPROVIDED FROM EACH LEVEL.
7. CEILING MOUNTED DEVICES SHALL BE A MINIMUM DISTANCE OF 4" FROM ANY WALL.
8. WALL MOUNTED DEVICES SHALL BE A MINIMUM OF 4" TO A MAXIMUM OF 12" FROM THE CEILING.
9. EACH DWELLING UNIT SHALL BE EQUIPPED WITH AN APPROVED TYPE SMOKE/CARBON MONOXIDEDETECTOR DEVICE.
10. SUCH SMOKE/CARBON MONOXIDE DETECTOR MUST BE EITHER THE IONIZATION OR PHOTO-ELECTRICTYPE.
PLUMBING AND DRAINAGE NOTES1. ALL PLUMBING AND GAS PIPING WORK SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THEREQUIREMENTS OF 2008 NEW YORK CITY PLUMBING CODE.
2. PLUMBING FIXTURES SHALL BE OF TYPE AND MANUFACTURE APPROVED FOR USE IN NEW YORK CITY,AND SHALL BEAR BS&A APPROVAL.
3. ALL GAS-FIRED EQUIPMENT TO BE A.G.A. OR M.E.A. APPROVED.
4. PLUMBING CONTRACTOR TO EXAMINE PROPOSED LAYOUT WITH REGARD TO EXISTING FIELDCONDITIONS, AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN ASSUMED FIELDCONDITIONS AND THOSE ENCOUNTERED DURING CONSTRUCTION. PLUMBING CONTRACTOR SHALLINFORM ARCHITECT OF ANY REVISIONS TO PLAN WHICH SHALL BE NECESSARY, BASED ON CONDITIONSUNCOVERED IN THE FIELD, IN ORDER TO INSTALL ALL FIXTURES, EQUIPMENT AND PIPING IN STRICTACCORDANCE WITH THE REQUIREMENTS OF THE NYC BUILDING CODE.
5. PLUMBING CONTRACTOR SHALL ARRANGE AND OBTAIN INSPECTIONS AND REQUIRED SIGN-OFFS.
NOTE: THIS PLAN IS APPROVED ONLY FOR WORK APPROVED ON THE APPLICATION SPECIFICATIONSHEET. ALL OTHER MATTERS SHOWN ARE NOT TO BE RELIED UPON, OR TO BE CONSIDERED AS EITHERAPPROVED OR IN ACCORDANCE WITH APPLICABLE CODES.
ALL PLUMBING WORK FILED UNDER SEPARATE LAA BY LICENSED PLUMBING. PLUMBING WORK SHOWNAS REFERENCE ONLY.
SITE SAFETYTHIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. THECONTRACTOR HAS THE RESPONSIBILITY FOR THE SUPERINTENDENCE OF CONSTRUCTION PROCESSES.SITE CONDITIONS, OPERATIONS, EQUIPMENT, PERSONNEL, THE MAINTENANCE OF A SAFE PLACE TOWORK AND ANY SAFETY IN, ON, OR AROUND THE SITE OF WORK.
LEAD NOTESTHE OWNER, GENERAL CONTRACTOR, DEMOLITION SUBCONTRACTOR ARE ADVISED THAT THERE IS APOSSIBILITY OF LEAD PAINT HAVING BEEN USED IN THE EXISTING CONSTRUCTION.THE DEMOLITION PORTION OF THE JOB MUST BE PERFORMED ACCORDING TO SAFE WORK PRACTICES(OSHA). INCLUDING WORKER PROTECTION, PREVENTION OF SPREAD OF LEAD DUST AND NOTIFICATION OFTHE PUBLIC AND GOV'T AGENCIES AND PROPER DISPOSAL OF CONTAMINATED REFUSE. AFTER THE DEMO ISPROPERLY FINISHED AND PROPER CLEAN UP IS PERFORMED, IT IS NO LONGER A LEAD ABATEMENT JOB.THE OWNER IS OBLIGED TO COMPLY WITH LOCAL LAW 1 OF 2004. COMPLY WITH ALL NYC LAWS.
SCOPE OF WORK NOTES1. THE SCOPE OF WORK FOR THIS PROJECT REQUIRES THE FILING OF AN ALTERATION TYPE 2 APPLICATION AT THENEW YORK CITY BUILDING DEPARTMENT. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING A PERMIT FOR THISWORK PRIOR TO CONSTRUCTION.
2. CONTRACTOR SHALL MAINTAIN PERMIT UNTIL ALL SIGN-OFFS ARE COMPLETE.
3. ALL CONTRACTORS SHALL BE LICENSED BY THE CITY OF NEW YORK FOR HIS/HER TRADE RESPECTIVELY.
ZONINGCONSTRUCTION CLASSIFICATION
1: FIREPROOF STRUCTURES
CCCUPANCY CLASSIFICATION
RES
SCOPE OF WORK
APPLICATION FILED FOR THE INTERIOR RENOVATION OF EXISTINGAPARTMENT #5E. NO CHANGE IN USE, OCCUPANCY, OR EGRESS.
ENERGY
TO THE BEST OF MY KNOWLEDGE, BELIEF AND PROFESSIONALJUDGEMENT, ALL WORK UNDER THIS APPLICATION IS INCOMPLIANCE WITH NYCECC 2011.
ZONING INFO
BLOCK: 1448LOT: 3ZONE: C1-9 R8BMAP: 8CBOROUGH: MANHATTANADDRESS: 300 EAST 74TH STREET PH-F
NEW YORK, NY 10021
NOTE: NO CHANGE IN BULK AND HEIGHT OF THEBUILDING IS PROPOSED IN THIS APPLICATION
NOTE: NO CHANGE TO USE, EGRESS OROCCUPANCY IS PROPOSED IN THIS APPLICATION
TENENT PROTECTION NOTES1. GENERAL:ALL WORK TO BE COMPLETED IN ACCORDANCE WITH THE NEW YORK BUILDING CODE, ARTICLE 19, ANDREGULATIONS OF ALL OTHER AGENCIES HAVING JURISDICTION. THE BUILDING CONTAINS UNITS THAT WILL BEOCCUPIED DURING CONSTRUCTION.
2. MEANS OF EGRESS:ALL EXISTING MEANS OF EGRESS FOR TENANTS OF THE BUILDING TO BE MAINTAINED CLEAR AND FREE OF ALLOBSTRUCTION, SUCH AS BUILDING MATERIALS, TOOLS, ETC.
3. FIRE SAFETY:A) ALL BUILDING MATERIALS, WHICH ARE STORED AT THE SITE OR ANY AREA OF THE BUILDING, ARE TO BESTORED IN A LOCKED AREA. ACCESS TO THE AREAS TO BE CONTROLLED BY THE OWNER, OR THE GENERALCONTRACTOR.B) ALL MATERIALS TO BE STORED IN AN ORDERLY FASHION.C) ALL FLAMMABLE MATERIALS TO BE KEPT AND TIGHTLY SEALED IN THEIR RESPECTIVE MANUFACTURER'SCONTAINERS. SUCH MATERIALS ARE TO BE KEPT FROM SOURCES OF HEAT.D) ALL FLAMMABLE MATERIALS TO BE USED AND STORED IN AN ADEQUATELY VENTILATED SPACE.E) ALL ELECTRICAL POWER TO BE SHUT-OFF WHERE THERE ARE EXPOSED CONDUIT.F) ALL ELECTRICAL POWER IN THE CONSTRUCTION AREA TO BE SHUT OFF AFTER WORKING HOURS.G) CONTRACTOR. AT ALL TIMES, SHALL ENSURE THERE IS NO NATURAL GAS LEAKAGE IN THE BUILDINGS, OR ANYFLAMMABLE GAS TO BE USED DURING CONSTRUCTION.
4. HEALTH REQUIREMENTS:A). DUST CONTROL: 1) DEBRIS, DIRT, AND DUST TO BE KEPT TO A MINIMUM AND CONFINED TO THE IMMEDIATE CONSTRUCTION AREA,AND SHALL NOT CREATE DUST, DIRT OR OTHER SUCH INCONVENIENCES TO OTHER APARTMENT UNITS WITHINTHE BUILDING. 2) CONTRACTOR SHALL ISOLATE CONSTRUCTION AREA FROM OCCUPIED BUILDING AREA BY MEANS OFTEMPORARY PARTITIONS OR HEAVY WEIGHT DROPCLOTH. 3) DEBRIS, DIRT, AND DUST SHALL BE CLEANED-UP AND CLEARED FROM THE BUILDING SITE PERIODICALLY TOAVOID EXCESSIVE ACCUMULATION.B). DISPOSAL OF CONSTRUCTION DEBRIS: ALL DEBRIS AND PRODUCTS OF DEMOLITION NOT DESIGNATED FORREFUSE SHALL BE REMOVED FROM THE PREMISES AND LEGALLY DISPOSED OF. THE SITE SHALL BE LEFT BROOMCLEAN AT THE END OF EVERY WORKING DAY.C). PEST CONTROL: SHALL CONFORM TO ARTICLE 13 OF THE NYC HOUSING MAINTENANCE CODE WITH REGARDSTO: 1) RODENT AND INSECT ERADICATION; MANDATORY EXTERMINATION` 2) ELIMINATION OF HARBORAGESD). MAINTENANCE OF SANITARY FACILITIES: SHALL CONFORM TO ARTICLE 14 OF THE NYC HOUSING MAINTENANCECODE.E). NOISE CONTROL: ALL WORK SHALL CONFORM TO LOCAL LAW 113/2005.F). LEAD: ALL WORK SHALL CONFORM TO LOCAL LAW 1/2004 WITH REGARDS TO THE HANDLING OF LEAD.G). ASBESTOS: ALL WORK SHALL CONFORM TO THE NYS DEP ASBESTOS CONTROL PROGRAM §1-01 WITHREGARDS TO THE HANDLING OF ASBESTOS.
5. STRUCTURAL SAFETY:NO STRUCTURAL WORK SHALL BE DONE THAT MAY ENDANGER THE OCCUPANTS.
6. NOISE RESTRICTIONS1) CONSTRUCTION OPERATION WILL BE CONFINED TO NORMAL WORKING HOURS: 8:00 AM TO 5:00 PM, MONDAY THRUFRIDAY, EXCEPT LEGAL HOLIDAYS. AFTER HOURS AND WEEKEND WORK BE SPECIAL PERMIT ONLY.2) CONTRACTOR MUST OBTAIN WRITTEN PERMISSION FROM ALL AFFECTED PARTIES TO WORK OUTSIDE OF THEREGULAR HOURS STATED ABOVE.
ELAM RESIDENCE300 EAST 74TH STREET PH-F, NEW YORK, NY 10021
ADA COMPLIANCE - LOCAL LAW 58/87ADA COMPLIANCE- LOCAL LAW 58/87 NOTES
1. ALL WORK TO COMPLY WITH LOCAL LAW 58/87. WORK IN BOTH THE KITCHEN AND THE BATHROOMS TO COMPLYWITH NYC DEPARTMENT OF BUILDINGS POLICY AND PROCEDURES NOTICES: PPN #15/88, PNN #1/92, PPN #3/92
2. NEW DOORWAYS AND FRAMED OPENINGS MUST COMPLY WITH ADA / NYC LOCAL LAW 58 OF 1987 CLEARANCEREQUIREMENTS. NEW DOOR HARDWARE AND THRESHOLDS TO BE ADA-COMPLIANT.
3. NEW ELECTRICAL OUTLETS, TELEPHONE OUTLETS, ETC, TO BE INSTALLED IN COMPLIANCE WITH AMERICANNATIONAL STANDARDS INSTITUTE (ANSI) A117.1 - 1986. NO OULET TO MOUNTED LESS THEN 15" AFF, SWITCHES TOBE MOUNTED NO HIGHER THAN 48" TO TOP OF BOX.
4. REPLACEMENT OF PLUMBING FIXTURES ON EXISTING ROUGHING DOES NOT MANDATE COMPLIANCE WITHHANDICAP ACCESSIBLITY REQUIREMENTS PER LOCAL LAW 58/87.
5. RELOCATION OR NEW FIXTURES INSTALLED TO COMPLY WITH LL58/87
PLUMBING RISER DIAGRAM - NOT TO SCALE
ASBESTOS NOTESIN THE EVENT OF ASBESTOS OR OTHER TOXIC SUBSTANCE EXPOSURE OR THE SUBSTANTIAL RISKTHEREOF, CLIENT WILL HAVE THE DUTY TO INFORM ARCHITECT OF SUCH RISKS KNOWN OR REASONABLYKNOWABLE TO CLIENT. IF ASBESTOS, OR ANY OTHER TOXIC SUBSTANCE, OR RISK TO EXPOSURE THERETOIS DISCOVERED BY THE ARCHITECT DURING WORK ON THE PROJECT, ARCHITECT SHALL, IN HIS SOLEDISCRETION, HAVE THE RIGHT TO SUSPEND WORK ON THE PROJECT. CLIENT SHALL HAVE THE DUTYPROMPTLY TO RETAIN A QUALIFIED EXPERT SAFELY TO REMOVE OR SUPERVISE THE REMOVAL OF SUCHASBESTOS OR OTHER TOXIC SUBSTANCE. CLIENT SHALL INDEMNIFY AND HOLD ARCHITECT, HIS AFFILIATESAND SUBCONTRACTORS, AND THEIR OFFICERS, AGENTS AND EMPLOYEES HARMLESS FROM ANY AND ALLLIABILITY ON THE PART OF OR DAMAGE TO SUCH ENTITIES OR PERSONS, INCLUDING THE COST OF LEGALFEES AND EXPENSES, AS SUCH FEES AND EXPENSES ARE INCURED, WHICH MAY RESULT FROM ASBESTOSOR OTHER TOXIC SUBSTANCE EXPOSURE ON THE PROJECT.
INTERIOR FINISH NOTES1. THE CONTRACTOR SHALL INSPECT ALL SURFACES AND PROVIDE ALL PREPARATORY WORK NECESSARY TO ACHIEVENEW FINISHES.
2. ALL AREAS SHALL BE FINISHED AS PER FINISH PLANS & RELATED NOTES ON CONSTRUCTION PLANS.
3. ON WALL SURFACES SCHEDULED TO RECEIVE PAINT, ALL PAINT SHALL BE APPLIED IN ACCORDANCE WITH THE MFR'SSPECIFICATIONS OR AS INDICATED.
4. ALL PAINTED CLGS. TO MATCH ADJACENT PAINT FINISH OR NEW PAINT FINISH SHALL BE FLAT LATEX U.O.N.
5. ONLY LOW VOC (VOLITILE ORGANIC COMPOUND) PAINT AND FLOOR FINISH MATERIALS WILL BE PERMITTED FOR USE.
PROGRESS INSPECTIONS:THE FOLLOWING SHALL BE SUBJECT TO PROGRESS INSPECTIONS
1. ENERGY CODE COMPLIANCE INSPECTIONS (BC 109.3.5) 2. FINAL INSPECTION (1RCNY-101-10)
SPECIAL INSPECTIONS:THE FOLLOWING SHALL BE SUBJECT TO SPECIAL INSPECTIONS
1. STRUCTURAL STEEL - WELDING (BC 1704.3.1) 2. STRUCTURAL STEEL - HIGH STRENGTH BOLTING (BC 1704.3.3) 3. STRUCTURAL STABILITY - EXISTING BUILDINGS (BC 1704.20.1) 4. FIRE RESISTANT PENETRATIONS AND JOINTS (BC 1704.27)
SHEET INDEXSheet # Sheet Name
A-000 GENERAL NOTES / PLOT PLANA-100 REMOVAL PLANSA-101 CONSTRUCTION PLANSA-102 ROOF PLANSA-103 REFLECTED CEILING PLANSA-104 FLOOR FINISHES PLANSA-201 KITCHEN ENLARGED PLANSA-202 KITCHEN ELEVATIONSA-203 BATHROOM ENLARGED PLANS &
ELEVATIONSA-204 BEDROOM ENLARGED PLANS &
ELEVATIONSA-205 MAIN FLOOR ENLARGED PLANS &
ELEVATIONSA-206 GREENHOUSE ENLARGED PLAN &
ELEVATIONSA-301 GREENHOUSE FRAMING PLANA-302 GREENHOUSE SECTIONSA-303 STAIRWELL PLANS & SECTIONSA-501 STAIR DETAILS IA-502 STAIR DETAILS IIA-503 GREENHOUSE DETAILSA-504 ROOF DETAILSA-505 FLOOR DETAILSA-506 CASEWORK DETAILSA-507 CEILING DETAILSA-600 FIXTURE, APPLIANCE, & DOOR
SCHEDULESA-601 FINISH SCHEDULESM-001 MECHANICAL SYMBOLS & NOTESM-100 MECHANICAL PLANS & SCHEDULESM-200 MECHANICAL DETAILS & SECTIONSM-300 MECHANICAL SPECIFICATIONSE-101 POWER PLANSP-101 PLUMBING PLANS
GAS RISER DIAGRAM - NOT TO SCALE
PLOT PLAN - NOT TO SCALE
ADA COMPLIANCE DIAGRAMS
No. Description Date
N
I. THE CONTRACTOR SHALL PROVIDE THE OWNER WITH THE NAMES AND PHONE NUMBERS OF ALLSUBCONTRACTORS USED DURING THE DEMOLITION (INCLUDING TRASH REMOVAL CONTRACTOR), THEDATES OF THE CONSTRUCTION IN THE TENANT PREMISES, AND COPIES OF ALL REQUIRED INSURANCECERTIFICATES, PRIOR TO THE COMMENCEMENT OF ANY WORK.
II. THE CONTRACTOR SHALL PROVIDE THE OWNER WITH A COPY OF ALL PERMITS BEFORECOMMENCEMENT OF RELEVANT WORK AS WELL AS DISPLAYING ALL PERMITS ON SITE.
III. THE CONTRACTOR SHALL CONSTRUCT DUST TIGHT PARTITIONS PRIOR TO THE COMMENCEMENT OFDEMOLITION AND ARE TO REMAIN IN PLACE UNTIL ALL WORK HAS BEEN COMPLETED AND WRITTENAPPROVAL HAS BEEN RECEIVED FROM THE OWNER. THE CONTRACTOR SHALL BE RESPONSIBLE FORANY AND ALL REPAIRS TO THE SURFACES MARKED OR DAMAGED BY THE PARTITION INSTALLATIONAND SUBSEQUENT REMOVAL, ALL SURFACES ARE TO BE RESTORED TO THEIR ORIGINAL CONDITION.
IV. GENERAL CONTRACTOR TO COOR. W/ OWNER FOR THE HOURS THAT THE DEMO WORK, INCLUDINGDEMOLITION REMOVAL CAN BE DONE. EXCEPTIONS WILL BE MADE ONLY WITH PRIOR APPROVAL FORMTHE LANDLORD.
V. IN THE EVENT THE CONTRACTOR FAILS TO PERFORM THE ABOVE SPECIFIED WORK DEEMEDNECESSARY BY THE OWNER, THE OWNER SHALL COMPLETE SUCH WORK AT CONTRACTOR'S /TENANT'S EXPENSE.
VI. DUST PROTECTION SHALL BE PROVIDED TO THE SPACES ADJACENT TO WORK BEING PERFORMED.CONTRACTOR REMAINS LIABLE FOR DUST AND DIRT INTRUSION INTO ADJOINING SPACE. ALL DUSTPROTECTION WORK TO BE COORDINATE WITH THE OWNER.
VIII. NO FLAMMABLE LIQUIDS OR MATERIALS SHALL BE STORED AT SITE JOB.
IX. AUTHORIZATION MUST BE OBTAIN FROM THE OWNER PRIOR TO COMMENCEMENT OF ANY CUTTINGWELDING WORK. LANDLORD WILL GIVE AUTHORIZATION ONLY AFTER RECEIPTOF PROOF OF ABURNER'S/ WELDER'S PERMIT.
X. THE CONTRACTOR SHALL CONSULT WITH THE OWNER PRIOR TO COMMENCEMENT OF ANY WORKTO DETERMINE WHETHER THERE ARE ANY KNOWN HAZARDOUS SUBSTANCES IN OR NEAR THEPREMISES. IF ANY HAZARDOUS SUBSTANCES IN OR NEAR ARE DISCOVERED DURING CONSTRUCTIONALL WORK IS TO STOP IMMEDIATELY AND NOTIFICATION GIVEN TO THE OWNER.
XI. REMOVE DEMOLISHED MATERIALS, TOOLS AND EQUIPMENT FROM SITE UPON OF COMPLETION OFWORK.
XII. DELIVERY OF ITEMS WILL BE ALLOWED BETWEEN THE HOURS OF 9:00 AM and 4:00 PM. ALLDELIVERIES SHOULD CLEARLY IDENTIFY STORE NAME.
XIII. CONTRACTOR SHALL VERIFY FIELD CONDITIONS AND NOTIFY ARCHITECT OF ALL DISCREPANCIESBEFORE PROCEEDING WITH WORK.
XIV.CEASE OPERATION AND NOTIFY THE OWNER IMMEDIATELY IF SAFETY OF STRUCTURE APPEARS TOBE ENDANGERED. TAKE PRECAUTIONS TO PROPERLY SUPPORT STRUCTURE. DO NOT RESUMEOPERATIONS UNTIL SAFETY IS RESTORED.
XV. THE CONTRACTOR SHALL EMPLOY CLEAN UP PERSONNEL TO MAINTAIN THE WORK AREA IN ANEAT AND ORDERLY MANNER, INCLUDING ANY AREA BEYOND THE DUST TIGHT PARTITIONS WHEREWORK IS OCCURRING, WHERE TRAFFIC HAS OCCURRED WHILE IMPLEMENTING WORK, OR WHERE DUST,DIRT, OR DEBRIS HAS MIGRATED THE PARTITION. THESE PERSONNEL SHOULD BE RESPONSIVE TODIRECTION GIVEN BY THE CONTRACTOR AND BY THE LANDLORD THE LANDLORD WILL BE COORDINATEALL CLEAN UP REQUEST THROUGH THE CONTRACTOR. HOWEVER, WHEN DEEMED NECESSARY, THEOWNER WILL DIRECT CLEAN UP PERSONNEL DIRECTLY AND SUBSEQUENTLY NOTIFY THECONTRACTOR. IN CASES WHERE THE BUILDING'S STAFF MUST CLEAN UP CONTRACTOR'S WORK, THECOST OF SUCH WORK WILL BE BORNE BY THE CONTRACTOR.
XVI.ARRANGE PAY FOR DISCONNECTION, REMOVING AND CAPPING UTILITY SERVICES WITHIN AREASOF DEMOLITION. DISCONNECT AND STUB OFF. NOTIFY THE AFFECTED UTILITY COMPANY AND BUILDINGMANAGER IN ADVANCED AND OBTAIN APPROVAL BEFORE STARTING THIS WORK.
XVII. PLACE MARKERS TO INDICATE LOCATION OF DISCONNECTED SERVICES. IDENTIFY SERVICELINES AND CAPPING LOCATIONS ON PROJECT RECORD DOCUMENTS.
XVIII. PERFORM DEMOLITION IN ACCORDANCE WITH APPLICABLE AUTHORITIES HAVINGJURISDICTION.
XIX.REPAIR ALL DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED, AT NO COST TO THE OWNER.
XX. G.C. TO NOTIFY ASBESTOS INVESTIGATOR OF ANY SUSPICIOUS MATERIAL UNCOVERED DURINGDEMOLITION NOT NORMALLY ACCESSIBLE.
XXI.ALL EXHAUST GRILLES SHALL BE CLOSED AND COVERED TO PREVENT THE SPREAD OF DUST INTOTHE SYSTEM UNTIL CONSTRUCTION IS COMPLETE.
XXIV. ANY DISRUPTION OF THE ELECTRICAL, PLUMBING AND MECHANICAL TO THE BUILDING SHALLBE COORDINATED WITH THE BUILDING SUPER AND MANAGEMENT WITH THE LENGTH OF TIMEDISRUPTION INDICATED.
GENERAL REMOVAL NOTES
-
REMOVAL KEYNOTESNo. Description
-
Scale:
ConsultantContactAddress
Phonee-mail
ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523
www.wilkinsonarchitects.com
New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561
National Council of Architectural Registration Board #52853
DOB Barcode
ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY 10001212.929.2491Ilya@atozengineers.com
ConsultantContactAddress
Phonee-mail
NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY 11372646-522-0589rhanna@engineer.com
MECHANICAL
STRUCTURAL
1/4" = 1'-0"
A-100
REMOVAL PLANS
ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021
04/03/2015
1/4" = 1'-0"1
Penthouse F - 36th Floor - Main LevelRemoval Plan
R1
R12
R1 REMOVE EXISTING NON-STRUCTURAL PARTITION. PATCH CEILINGS, WALLS, AND FLOORS AS REQUIRED WITH MATERIALS TO MATCH EXISTING.
R2 REMOVE EXISTING WALL TILE FINISH AND BACKERBOARD IN BATHROOMS AND KITCHEN.
R3 REMOVE EXISTING DOOR AND FRAME. PATCH CEILINGS, WALLS, AND FLOORS AS REQUIRED WITH MATERIALS TO MATCH EXISTING.
R4 REMOVE EXISTING CASEWORK. PATCH CEILINGS, WALLS, AND FLOORS AS REQUIRED WITH MATERIALS TO MATCH EXISTING.
R5 REMOVE EXISTING COUNTERTOP AND BACKSPLASH.
R6 REMOVE EXISTING FLOOR FINISH DOWN TO SUB-FLOOR.
R7 REMOVE EXISTING RAISED PLATFORM. REMOVE ANY PLUMBING BELOW BACK TO RISERS. CAP AT CONNECTION WITH RISER.
R8 REMOVE EXISTING FANCOIL UNIT AND ENCLOSURE.
R9 REMOVE EXISTING PLUMBING FIXTURE AND ALL ASSOCIATED SUPPLY AND WASTE LINES BACK TO RISER. WELD CAP AT CONNECTION WITH RISER.
R10 REMOVE EXISTING KITCHEN APPLIANCE.
R11 REMOVE FINISH AROUND COLUMN TO EXPOSE STRUCTURAL CONCRETE.
R12 REMOVE EXISTING MANTEL, SURROUND, FLUE ENCLOSURE, AND HEARTH. EXISTING SOLID FUEL FIREBOX AND FLUE TO REMAIN.
R1
R4
R8
R8
R1 R1
R3
R3
R3
R7
R13
R13 REMOVE EXISTING STAIRCASE.
R1
R3 R9
R4
R4
R6
R6
R6R6
R6
R6
R5
R5R9
R10
R14 REMOVE EXISTING ELECTRICAL PANELS. DO NOT INTERFERE OR ALTER ELECTRICAL RISER. SEE E-100 FOR RELOCATION.
R14
R6
1/4" = 1'-0"2 Penthouse F - Upper Level Removal Plan
R6
R1
R1
R3
R2
R2
R3
R9
R18
R15 REMOVE EXISTING WALL FINISHES ABOVE AND BELOW GREENHOUSE GLAZING DOWN TO FRAMING. MAINTAIN EXISTING EXTERIOR FINISH ON SOUTH SIDE OFWALL. SEE CONSTRUCTION KEYNOTE 2 ON SHEET A-101.
R16 REMOVE EXISTING GREENHOUSE GLAZING AND KNEEWALL. PATCH AND REPAIR EXTERIOR WALLS AND FLOORS AS REQUIRED WITH MATERIALS TO MATCH EXISTING.
R16
R16
WALK -INCLOSET
MASTERBEDROOM
MASTERBATHROOM
GREENHOUSE
ROOF TERRACE
EXISTING FLUE ANDCOVERING TO REMAIN
R6
R6
R6
R1
R4
R4
R4
R6
R3
R1
R13
R15
R8
STAIRWELL
R6
R6R9
R3
UP
BALCONY
DINING
LIVINGKITCHEN
FOYERCL
CL
CL
CORRIDOR
BEDROOM
M. BATH
POWDER
R8R4
R4
R6
R17 SALVAGE EXISTING INTERCOM FOR RELOCATION.
R17
R17
R4
R18 DRAIN HOT TUB TO ROOF TERRACE WITH SYPHON PUMP BEFORE REMOVAL. CUT AND REMOVE TUB IN MANAGABLE SECTIONS, THEN REMOVE FRAMING.
R11
LAV WC
WC
LAV
SHOWER
PH-F
GAS RANGE
REF
SINKDW
FP
HOT TUB
SHOWER
WC
LAV
LAV
No. Description Date1 DOB Submission 02/06/2015
N N
NO WORK
R2
TYP
NO WORK
I. ALL CONTRACTORS & THEIR SUB-CONTRACTORS SHALL VISIT, BECOME FAMILIARIZED, & VERIFY ALL EXISTINGCONDITIONS PRIOR TO SUBMITTING A PROPOSAL. SUBMISSION OF A PROPOSAL WILL BE CONSTRUED AS EVIDENCE THATSUCH AN EXAMINATION HAS OCCURED & LATER CLAIMS WILL NOT BE RECOGNIZED FOR EXTRA LABOR, EQUIPMENT ORMATERIALS REQUIRED BECAUSE OF DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN, HAD SUCH ANEXAMINATION BEEN MADE. THIS EXAMINATION IS TO INCLUDE BUT NOT LIMITED TO VERIFYING WEIGHT, STRUCTURALLIMITATIONS, CLEARANCES, & MANEUVERING SPACE ASSOCIATED W/REMOVAL OF LARGE EQUIPMENT FROM BUILDINGPREMISES, OR ANY SUCH FORSEEABLE SPECIAL REQUIREMENTS. CONTRACTOR SHALL INCLUDE A PRICE BREAKDOWN FORSPECIAL REQUIREMENTS DUE TO SITE RESTRICTIONS OR CONDITIONS.
II. ALL CONTRACTORS AND/OR SUB-CONTRACTORS SHALL OBTAIN DEMOLITION AND/OR CONSTRUCTION PERMITS AND / ORAUTHORIZATIONS FROM THE BUILDING DEPARTMENT, ARCHITECT, CLIENT, TENANT, AND / OR ENGINEERS AS REQUIREDPRIOR TO THE COMMENCEMENT OF WORK. A COPY OF SUCH DOCUMENTS SHALL BE FURNISHED TO THE OWNERS AND THEARCHITECT PRIOR TO THE COMMENCEMENT OF WORK.
III. WHILE PERFORMING DUTIES ASSOCIATED WITH THIS CONTRACT ALL CONTRACTORS, SUB-CONTRACTORS, AND THEIRWORKERS SHALL COMPLY WITH ALL OSHA RULES AND REGULATIONS & WITH THE STANDARD RULES AND REGULATIONS SETFORTH BY THE OWNERS.
IV. ALL CONTRACTORS AND THEIR SUB-CONTRACTORS SHALL COORDINATE THEIR WORK WITH OTHER TRADES AND WILLCONFER WITH ARCHITECT.
V. PROTECT ALL WINDOWS AND VENTS FROM DEBRIS AND DUST DURING CONSTRUCTION. KEEP PREMISES CLEAN AND DONOT LET DEBRIS, RUBBISH, OR EXCESS CONSTRUCTION MATERIAL ACCUMULATE OR OBSTRUCT EXITS AND EXITPASSAGEWAYS.
VI. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY ERRORS, OMISSIONS, CONFLICTS OR AMBIGUITIES WITHINAND BETWEEN THE PLANS, DRAWINGS, AND SPECIFICATIONS COMPRISING THESE CONTRACT DOCUMENTS PRIOR TOSUBMITTING HIS BID PROPOSAL. IF SUCH NOTICE IS NOT FURNISHED TO THE ARCHITECT, THE CONTRACTOR SHALL BEDEEMED TO HAVE INSPECTED THE PLANS, DRAWINGS, SPECIFICATIONS AND JOB CONDITIONS AND HAVE FOUND THEM INPROPER FORM FOR EXECUTION.
VII. THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR CONSTRUCTION MEANS, TECHNIQUES, SEQUENCES ORPROCEDURES, OR FOR THE SAFETY PRECAUTIONS IN CONNECTION WITH THE WORK.
VIII. DRAWINGS ARE NOT TO BE SCALED. FOLLOW DIMENSIONS SHOWN.
IX. NO CHANNELING, CUTTING OR CHOPPING OF ANY STRUCTURAL SLAB, ELEMENTS, DEMISING WALLS AND EXTERIORWALLS OR PIPE CHASE / SHAFT ENCLOSURE WALLS SHALL OCCUR DURING THE COURSE OF ANY WORK.
X. NO REMOVAL OF MASONRY BACK-UP MATERIAL AT EXTERIOR OR SHAFT WALLS SHALL OCCUR FOR INSTALLATION OFJUNCTION BOXES, ETC.
XI. ALL FIREPROOFING MUST BE MAINTAINED. ANY FIREPROOFING THAT IS DISTURBED DURING THE COURSE OF THERENOVATION IS TO BE RECONSTITUTED TO CODE COMPLIANT RATINGS.
XII. NO OFFSET OF RISERS (PLUMBING, GAS, ETC) SHALL OCCUR.
XIV.ALL PLUMBING SHALL BE DONE BY A NEW YORK CITY LICENSED PLUMBER AND ALL ELECTRICAL WORK BY A NYCLICENSED ELECTRICIAN IN ACCORDANCE WITH N.Y.C. BUILDING CODES AND REGULATIONS.
XV. PROVIDE NEW BRANCH LINES AT ALL NEW FIXTURES FOR WASTE, VENT AND SUPPLY LINES BACK TO THE RISERS, WITHNEW ACCESSIBLE SHUT-OFF VALVES AT RISER. WASTE LINES MUST BE RE-USED WHERE WHERE CURRENTLY LOCATED INTHE CONCRETE SLAB OR NEW LINES RUN ABOVE THE STRUCTURAL SLAB. INSTALL NEW SUPPLY BALL TYPE STOP VALVESFOR EACH LAV AND TOILET AND NEW BALL SHUT-OFF VALVES FOR THE BATHROOM AS A WHOLE. FIRE RATED ACCESSPANELS ARE REQUIRED AT ALL SHUT-OFF VALVES.
XVI.THE USE OF ELECTRICAL OR AIR HAMMER OR OTHER PNEUMATIC TOOLS ARE NOT PERMITTED TO BE USED DURINGCONSTRUCTION DUE TO THE NOISE FACTOR UNLESS SPECIAL PERMISSION IS GRANTED.
XVII. ALL NECESSARY ELECTRIC, GAS & WATER WORK MUST BE PERFORMED LOCALLY WITHIN THE APARTMENT. ALLNECESSARY SHUTDOWNS SHALL BE COORDINATED WITH THE BUILDING SUPER AND MANAGEMENT. SHUT DOWNS OFSERVICE RISERS TO RELOCATE ELECTRIC PANEL BOXES, SERVICE RISERS OR TO PERFORM PLUMBING WORK WILL NOT BEPERMITTED.
XVIII. PLUMBER TO PROVIDE BACKFLOW PREVENTORS AND BALL VALVES AT ALL PIPE OUT LOCATIONS.
XIX.REPLACE ALL SUPPLY, VENT AND SANITARY LINES BACK TO RISER AT KITCHEN. INSTALL NEW BALL TYPE SHUT-OFFVALVES AT SINK, DISHWASHER AND REFRIGERATOR WATER LINE, AND MASTER SHUT-OFF VALVES FOR KITCHEN AS AWHOLE.
XX. ALL WATER LINES ARE TO BE INSTALLED WITH THERMAL / ACOUSTIC INSULATION TO MINIMIZE SWEATING AND NOISETRANSMISSION, INCLUDING ELBOWS AND FITTINGS.
XXI.ISOLATE COPPER PIPING FROM DISSIMILAR MATERIAL TO PREVENT GALVANIC CORROSION.
XXII. NO PENETRATION THROUGH ANY EXTERIOR WALL IS PROPOSED NOR PERMITTED AS PART OF THIS ALTERATION.
XXIII. GC TO VERIFY THE LOCATION OF ALL EXISTING CONNECTIONS TO THE STACK. BUILDING MANAGEMENT TO INSPECTAND NOTIFY OF OTHER PLUMBING TO BE REPLACED.
XXIV. ALL EXHAUST GRILLES AND DAMPERS MUST BE MAINTAINED, REMAIN ACCESSIBLE AND IN OPERATION. UPONCOMPLETION OF WORK, ALL GRILLES AND DAMPERS ARE TO BE CLEANED.
XXV. GC TO TAKE MEASURES TO INSURE THAT OTHER PORTIONS OF THE BUILDING ARE NOT DAMAGED. ALL EXISTINGCONSTRUCTION ADJACENT TO PUBLIC AREAS OR OTHER APARTMENTS AFFECTED BY THE PROPOSED WORK IS TO BEPATCHED BACK TO IT'S ORIGINAL CONDITION USING MATCHING MATERIALS.
XXVI. NO STORAGE OR WORK IS PERMITTED IN COMMON AREAS AND FIRE STAIRS.
XXVII. PLUMBER MUST CHECK EXISTING WASTE AND VENT LINES TO BE FREE OF OBSTRUCTION.
XXVIII. CEMENT BOARD IS TO BE USED AT ALL SHOWER, TUB ENCLOSURES AND TILED AREAS. MOLD AND MOISTURERESISTANT WALL BOARD AT ALL OTHER DESIGNATED "WET AREAS".
XXIX. FIXTURE PIPING BETWEEN SHUT-OFF VALVE AND THE FAUCET OR APPLIANCE TO BE COPPER TUBING WITH FLAREDENDS AND BRASS BUSHINGS, OR BRASS COMPRESSION FITTINGS. (NO PLASTIC; RUBBER OR BRAIDED STAINLESS STEEL.HIGH PRESSURE "NO BURST" BRAIDED STAINLESS STEEL WILL BE ALLOWED TO HOOK-UP APPLIANCES THAT DO NOT HAVEACCESS AFTER INSTALLATION IF DEMONSTRATED THERE IS NO PRACTICAL ALTERNATIVE.)
XXX. THE CONTRACTOR SHALL MAINTAIN ADEQUATE, CLEARLY IDENTIFIED FIRE EXTINGUISHERS THROUGHOUT THE AREAOF WORK.
XXXI. GC TO PROVIDE A COMPLETE PHOTOGRAPHIC SURVEY OF THE ADJACENT APARTMENTS AND PUBLIC SPACES PRIORTO THE COMMENCEMENT OF ANY WORK TO IDENTIFY PRE-EXISTING CONDITIONS. A COPY OF THE SURVEY SHALL BEDELIVERED TO THE MANAGING AGENT.
XXXII. HOT AND COLD BRANCH LINES MUST BE REPLACED AT THE RISER'S CONNECTIONS.
XXXIII. FOUR-ELBOW SWING MUST BE INSTALLED ON THE HOT WATER BRANCH LINE.
XXXIV. WATTS PRESSURE REDUCING VALVES MODEL U5B-Z3 MUST BE INSTALLED ON THE HOT AND COLD WATER BRANCHLINES.
XXXV. SPRING LOADED CHECK VALVES MUST BE INSTALLED ON THE HOT AND COLD WATER BRANCH LINES.
XXXVI. APOLLO BALL VALVES MUST BE INSTALLED ON THE HOT AND COLD WATER BRANCH LINES.
XXXVII. PLUMBERS ARE REQUIRED TO USE TYPE L COPPER TUBING TO SUPPLY WATER TO TOILETS AND SINKS.
XXXVIII.PLUMBERS ARE PROHIBITIED FROM USING PLASTIC TUBING AND/OR RUBBER HOSES TO SUPPLY WATER TOREFRIGERATORS, DISHWASHERS, WASHING MACHINES, INSTANT HOT WATER MAKERS, TOILETS, SINKS AND WATERFILTERS.
XXXIX. PLUMBERS ARE REQUIRED TO INSTALL McGUIRE VALVES UNDER THE SINKS AND TOILETS. PLASTIC STEM VALVESARE PROHIBITIED.
XXXX. GARBAGE DISPOSALS ARE PROHIBITIED.
XXXXI. REGARDING INSTALLATION OF SHOWER STALLS, THE CONTRACTOR AND PLUMBER ARE REQUIRED TO INSTALL ATWO-INCH DRAIN WITH WEEP HOLES AND P-TRAP. TWO-INCH DRAIN MUST BE CONNECTED TO THE EXISTING STACK.
XXXXII. REGARDING INSTALLATION OF SHOWER STALLS, THE CONTRACTOR AND PLUMBER ARE REQUIRED TO USE A 6GUAGE LEAD PAN THAT RETURNS UP THE WALL A MINIMUM OF 12-INCHES.
XXXXIII. REGARDING INSTALLATION OF SHOWER STALLS, THE CONTRACTOR AND PLUMBER ARE REQUIRED TO APPLY A COATOF "BLACK MAGIC" TO THE TOP PORTION OF THE LEAD PAN. "BLACK MAGIC" EXTENDS THE LIFE OF THE PAN AND PREVENTSTHE LEAD PAN FROM DIRECT CONTACT WITH CEMENT WHICH CORRODES AND DAMAGES THE LEAD PAN.
XXXXIV. WHEN A WOODEN PLATFORM IS CONSTRUCTED TO CREATE A SHOWER STALL, THE CONTRACTOR IS REQUIRED TOUSE A MINIMUM OF 3/4-INCH THICK PLYWOOD.
XXXXVI. CONTRACTORS ARE PROHIBITED FROM DRILLING NAILS AND SCREWS THROUGH ANY PORTION OF THE LEAD PAN.
XXXXVII. REGARDING INSTALLATION OF WASHER AND DRYER UNITS, HOT AND COLD WATER VALVES MUST BE INSTALLED TOTHE SIDE OF EACH MACHINE FOR EASY ACCESS IN THE EVENT THE MACHINE NEEDS TO BE SERVICED.
XXXXVIII. REGARDING INSTALLATION OF WASHER AND DRYER UNITS, ALL FLOORING BENEATH MACHINES MUST BE WATERPROOFED AND SEALED.
XXXXIX. WASHER UNITS MUST BE SET ON VIBRATION ISOLATORS INSTALLED IN A WATERPROOF PAN.
XXXXX. REGARDING INSTALLATION OF WASHER AND DRYER UNITS, A FLOOD STOP KIT MUST BE INSTALLED ON THE HOTAND COLD WATER HOSES.
XXXXXI. REGARDING INSTALLATION OF WASHER AND DRYER UNITS, EASILY ACCESSIBLE BACKFLOW PREVENTORS NEED TOBE INSTALLED ON THE HOT AND COLD WATER BRANCH LINES.
XXXXXII. DRYER UNITS MUST BE VENTLESS TYPE UNITS. VENTED DRYER UNITS ARE PROHIBITED.
GENERAL CONSTRUCTION NOTES
UP
1
3
1
4
1
1
ALIGN
11
ALIGN
5' -
0"
8' -
6 1
/2"
1' -
10
3/4"
9' -
7 1
/4"
3
2
MIN CLEAR3' - 0"
6' -
0 3
/4"
5' -
1"
9' -
0 1
/4"
1' -
8"
VE
RIF
Y IN
FIE
LD
21' -
10"
13' - 2 3/4"VERIFY IN FIELD
9' - 2 1/4"
ALIGN
ALI
GN
A-2053
2
VE
RIF
Y IN
FIE
LD6'
- 1
1 3/
4"V
IF1'
- 1
0"
VERIFY IN FIELD18' - 6"
VIF2' - 10 1/4"
VERIFY IN FIELD7' - 8 1/2"
1
1
SD
SD
EXG
16R
15T
7
A-1013
A-1014
A-1015
4' - 6"
13' - 9 3/4"VERIFY IN FIELD
27' - 0 1/2"
VE
RIF
Y IN
FIE
LD26
' - 6
3/4
"
1
A-505
1
A-505
6
A-505
A-3031
ALIGN
A-2056
5
8
1
3
1
1
UP
16R
4
6
5
17' - 0 1/4"1 3/4"
1' - 11"
15' -
3"
DN
6"11
' - 1
0"
SD
6' -
8" SD
15T
1R 0T
8
2' -
2 1
/4"
1
A-302
MA
TC
H E
XT
EN
TS
OF
EX
G G
RE
EN
HO
US
E
10' -
5 3
/4"
± (V
ER
IFY
IN F
IELD
)
MATCH EXTENTS OF EXISTING GREENHOUSE BEING REMOVED17' - 3 3/4" ± (VERIFY IN FIELD)
4
A-505
A B
1
7
A-505
SD
1
A-506
FC
U-3
FC
U-1
2
CONSTRUCTION KEYNOTESNo. Description
CLE
AR
2' -
8"
MINIMUM1' - 6"
MINIMUM1' - 6" 1' - 6"
3
MINIMUM2' - 0"
MIN
1' -
0"
MIN
IMU
M2'
- 0
"
MINIMUM2' - 0"
MAX1' - 0"
MA
X
1' -
0"
MIN
IMU
M
1' -
6"
WC 4
8" X
56"
LAV 30" X 48"
SHOWER 30" X 48"
18" VERTICALGRAB BAR
WOOD BLOCKING (TYP)CLE
AR
2' -
8"
1
MINIMUM1' - 6"
WC 4
8" X
56"
LAV 30" X 48"
MINIMUM2' - 0"
6"
MIN
IMU
M
1' -
6"
18" VERTICALGRAB BAR
WOOD BLOCKING (TYP)
METAL RUNNER (TYP)
TOP OF FLOOR
5/8" GWB EACH SIDETO U/S OF CEILING
3 5/8 " METAL STUDS(MAY VARY) @ 16" O.C.
U/S OF CEILING
ROOM PARTITION F.H.
5/8" FIRE RATED GWBINTERIOR SIDE ONLY (2LAYERS FOR FIRE RATING)
U/S OF CEILING
ROXUL SAFE 'N'SOUND MINERALWOOL INSULATION
SOLID WOODSTRIP
5/8" GWB EACHSIDE TO U/S OFCEILING
1-1/2" METALSTUDS @ 16" O.C.
U/S OF CEILING
5/8" GWB. EACHSIDE TO U/S OFCEILING
U/S OF CEILING
J - BEAD METAL RUNNER (TYP)TOP OF FLOOR
20 GA METAL STUDS(SIZE VARIES) @ 16" O.C.
HILTI FIRE FOAM CP620J - BEAD
METAL RUNNEREACH SIDE (TYP)
TOP OF FLOOR
SOLID WOOD STRIP
J - BEAD(TY
P)
1FURRED-OUT WALL F.H.
2POCKET DOOR WALL F.H.
3PLUMBING CAVITY F.H.
4
PARTITION WALL TYPE#
EXISTING WALL
VIBRATIONISOLATION PADDING
HILTI FIRE FOAM CP620
WALL CLIPS AS NEEDED
Non Fire RatedSTC: 51-56
Fire RatingSTC Rating
Maintain EXG Fire Rating As Req'dSTC: 40-48
Non Fire RatedSTC: 40-44
Non Fire RatedSTC: 40-48
(SIZE VARIES)AIR SPACE
1/4"
1/4"
(TY
P)
(TY
P)
1/4"
POCKET DOOR CAVITY
1-1/2" METALSTUDS @16" O.C.METAL RUNNEREACH SIDE (TYP)
TOP OF FLOOR
SOLID WOODSTRIP
J - BEAD
1/4"
(TY
P)
CLEAR FLOOR SPACE
ø 5' - 6"
5' - 0"
6' -
7"
EXTENTS OF NEW/EXISTING WET AREA(SEE FLOOR DETAILS ON SHEET A-501)
FLOOR FINISH LEGEND
STONE TILE FLOOR FINISH(SEE FLOOR DETAILS ON SHEET A-501)
HARD WOOD FLOOR FINISH(SEE FLOOR DETAILS ON SHEET A-501)
Graphic Description
Scale:
ConsultantContactAddress
Phonee-mail
ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523
www.wilkinsonarchitects.com
New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561
National Council of Architectural Registration Board #52853
DOB Barcode
ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY 10001212.929.2491Ilya@atozengineers.com
ConsultantContactAddress
Phonee-mail
NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY 11372646-522-0589rhanna@engineer.com
MECHANICAL
STRUCTURAL
As indicated
A-101
CONSTRUCTION PLANS
ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021
04/03/2015
1/4" = 1'-0"1
Penthouse F - 36th Floor - Main LevelConstruction Plan
1/4" = 1'-0"2 Penthouse F - Upper Level Construction Plan
1 NEW RAISED PLATFORM UNDER STAIR. PLATFORM HEIGHT TO MATCH STAIR RISER HEIGHT.PLATFORM FLOOR FINISH TO MATCH STAIR TREAD FINISH. SEE SHEET A-303.
2 REINSULATE EXISTING FRAMING AND FINISH WITH GWB. DO NOT DISTURB OR ALTER EXISTINGEXTERIOR FINISH.
3 NEW DOOR, FRAME, AND HARDWARE. SEE DOOR REFERENCE CHART.
4 NEW KITCHEN CASEWORK. SEE ELEVATIONS ON SHEET A-202.
5 NEW REFRIGERATOR. EXTEND COPPER TUBE WATER SUPPLY TO ICE MAKER. SEE APPLIANCESCHEDULE ON SHEET A-600.
6 NEW DISHWASHER. SEE APPLIANCE SCHEDULE ON SHEET A-600.
7
8
9
NEW STAIRCASE WITH CONTINUOUS 1-3/8" WIDE HANDRAIL INSTALLED 36" HIGH.
10 NEW BUILT-IN STORAGE FURNITURE.
11 NEW WALL HUNG SHELVING UNIT. SEE DETAILS ON SHEET A-506.
12
NEW STONE MANTEL OVER EXISTING FIREPLACE. NO WORK TO FIREPLACE OR EXISTING FLUE.
13 NEW RECIRCULATING HOOD OVER GAS RANGE. SEE APPLIANCE SCHEDULE ON SHEET A-600.
14 NEW WALL MOUNTED TOILET. SEE PLUMBING FIXTURE SCHEDULE ON SHEET A-600.
15 NEW BATHROOM LAVATORY. SEE PLUMBING FIXTURE SCHEDULE ON SHEET A-600.
16
REPLACE PTAC UNIT AND ENCLOSURE. REPLACEMENT UNITS MUST BE CERTIFIED ANDINSTALLED BY A NYC LICENCED PLUMBER. REPLACEMENT ENCLOSURES MUST HAVE SERVICEACCESS PANELS AND INTERNAL DUCT (PAINTED MATTE BLACK) BETWEEN PTAC UNIT AND GRILL.
1
3
3
21
21
EXISTING EXPOSEDCONCRETE COLUMN
MASTERBEDROOM
MASTERBATHROOM
GREENHOUSE
ROOF TERRACE
STAIRWELL
LIVING
DININGKITCHEN
FOYER
CORRIDOR
BEDROOM
POWDER
10
10
EXISTING FLUEAND COVERINGTO REMAIN
17
NEW UNDERCOUNTER WINE STORAGE. SEE APPLIANCE SCHEDULE ON SHEET A-600.18
19 NEW INTEGRATED WINE STORAGE. SEE APPLIANCE SCHEDULE ON SHEET A-600.
20 NEW STACKABLE WASHER/SELF-CONDENSING DRYER. PROVIDE NEW FLOOR DRAIN ANDMETAL PAN MIN 3" CURB W/ WATER SENSOR AND AUTOMATIC SHUT OFF VALVE.
21
NEW ACCESS PANEL TO WATER SUPPLY SHUT OFF FOR AREA INDICATED.22
23
24
25
NEW STAINLESS STEEL UNDERMOUNT KITCHEN SINK. SEE PLUMBING FIXTURE SCHEDULE ONSHEET A-600.
REPLACE GREENHOUSE ENCLOSURE. SEE SHEETS A-301, A-302, AND A-503.NOTE: GREEHOUSE STRUCTURE APPROVED UNDER PRIOR NYC DOB APPLICATION #BH594-85.
NEW SKYLINE TERRACE DOOR AND TILT & TURN CASEMENT WINDOWS WITH FASTENERS @16" O.C. FINISH TO MATCH EXISTING FENESTRATION. SEE SHEETS A-301, A-302, AND A-503.
BALCONY
NEW SHOWER UNIT. SEE PLUMBING FIXTURE SCHEDULE ON SHEET A-600.
PARTITION TYPES
W/D
BATH
NO WORK
NO WORK
CL
2
7
19
26
10
3
REPLACE SKYLIGHT ABOVE(SEE DETAIL SHEET A-504)
8
8
8
8
15
15
11
9
14
13
5
17
10
14
1614
15
24
21
7
(TYP)
6
ENLARGED PLANS FORADA ADAPTABLE USE
1/2" = 1'-0"4 Main Level Bath Enlarged ADA Plan
1/2" = 1'-0"3 Main Level Powder Enlarged ADA Plan
NO WORK
NEW STAINLESS STEEL UNDERMOUNT BAR SINK. SEE PLUMBING FIXTURE SCHEDULE ON SHEETA-600.
22
203
1/2" = 1'-0"5 Main Level Kitchen Enlarged ADA Plan
DOOR REFERENCE CHARTMark Height Width Thickness Comments
1 8' - 0" 2' - 8" 1 1/2" 1ST FLR: POWDER RM2 7' - 10" 4' - 10 1/2" 2" 1ST FLR: BEDROOM3 8' - 0" 2' - 8" 1 1/2" 1ST FLR: BATHROOM4 7' - 10" 4' - 5 3/4" 2" 2ND FLR: MASTER BEDROOM5 8' - 0" 2' - 8" 1 1/2" 2ND FLR: MASTER BATHROOM6 6' - 8" 2' - 6" 2" 2ND FLR: GREENHOUSE7 7' - 9" 2' - 7" 3/8" 1ST FLR: BATH SHOWER8 7' - 8" 2' - 11 1/4" 3/8" 2ND FLR: MASTER BATH SHOWER9 7' - 11" 3' - 0" 1 3/4" 2ND FLR: GREENHOUSE
MAINTAIN CLEARANCETO ACCESS EXISTINGROOF DRAIN. VERIFYLOCATION IN FIELD.
EXISTING BATHROOMVENT EXTENDED TONEW LOCATION.
22
22
(M. BATH)
(GARDEN SINK)
(W/D)
LOWEREDCOUNTERTOP
NOTE: GREEHOUSE STRUCTUREAPPROVED UNDER PRIOR NYC DOBAPPLICATION #BH594-85
NOTE: ALL WALL DIMENSIONS SHOWN ARE FROM FINISH FACE TO FINISH FACE NOTE: ALL WALL DIMENSIONS SHOWN ARE FROM FINISH FACE TO FINISH FACE
REPLACE SKYLIGHT ABOVE(SEE DETAIL SHEET A-504)
23
16
4
12
18
4
4
(TYP)
(TYP)
26
NEW 5/8" SOLARBAN 60 INSULATED GLASS WINDOW UNITS. ALL FINISHES TO MATCH EXISTINGFENESTRATION. SEE SHEET A-505.
25
No. Description Date
NEW CERAMIC TILE WALL FINISH WITH BACKERBOARD IN WASHROOMS.
10
LAV
WC
WC
SHOWER
LAV
3
LAV
SHOWERHALL
WC
SINK
CL
CL
LAV
WC
SHOWERLAV
WC
SINK D/W
REF
F/P
REF
SINK
D/W
NEW GAS RANGE. PROVIDE ACCESSIBLE FIXTURE SHUT OFF VALVE IN KITCHEN. SEEAPPLIANCE SCHEDULE ON SHEET A-600.
REF
PENTHOUSE F
GA
S R
AN
GE
GA
S R
AN
GE
NOT TO SCALE
N N
3
24
CU-1
1
A-302
1
A-504
TYP
1
A-504
TYP
3
A-504
TYP
A B
1
I. ANY ALTERATION TO ROOFING DURING REMOVAL AND CONSTRUCTION MUST BE PERFORMED BYTHE BUILDING'S ROOFING CONTRACTOR (YORK RESTORATION CORP.) TO MAINTAIN WARRANTY.
GENERAL ROOF NOTES
REMOVAL KEYNOTESNo. Description
CONSTRUCTION KEYNOTESNo. Description
Scale:
ConsultantContactAddress
Phonee-mail
ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523
www.wilkinsonarchitects.com
New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561
National Council of Architectural Registration Board #52853
DOB Barcode
ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY 10001212.929.2491Ilya@atozengineers.com
ConsultantContactAddress
Phonee-mail
NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY 11372646-522-0589rhanna@engineer.com
MECHANICAL
STRUCTURAL
1/4" = 1'-0"
A-102
ROOF PLANS
ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021
04/03/2015
1/4" = 1'-0"2
Penthouse F - Upper Level RoofConstruction Plan
1/4" = 1'-0"1
Penthouse F - Upper Level Roof RemovalPlan
EXISTING ROOFDRAIN TO REMAIN(DO NOT DISTURB)
EXISTING FLUE ANDCAP TO REMAIN(DO NOT DISTURB)
EXISTING 4" Ø VENTPIPE TO REMAIN
EXISTING JUNCTIONBOX TO REMAIN
EXISTING FIRE SAFETYRAILING TO REMAIN(DO NOT DISTURB)
SEE DRAWING 3 ON M-100FOR MECHANICAL WORK
No. Description Date
UPPER LEVEL ROOF
D1 REMOVE EXISTING GREENHOUSE INSULATED GLASS ENCLOSURE.
D2 REMOVE PORTION OF EXISTING KNEE WALL DOWN TO HEIGHT OF GREENHOUSE FLOOR SUBSTRATE.
D3 REMOVE EXISTING SKYLIGHT. COORDINATE WITH REPLACEMENT INSTALLATION. SEE GENERAL ROOF NOTE I.
D4 REMOVE EXISTING AIR HANDLER. EXISTING MECHANICAL EQUIPMENT SLAB TO REMAIN. SEE GENERAL ROOF NOTE I.
D5 REMOVE EXISTING DUCTING AND SUPPORTS BETWEEN AIR HANDLER AND ROOF SLEEVE. SEE GENERAL ROOF NOTE I.
D6 REMOVE EXISTING ROOF SLEEVE. COORDINATE WITH ROOF REPAIR WORK TO FILL OPENING. SEE GENERAL GENERAL ROOF NOTE I.
D7 REMOVE EXISTING AIR HANDLER ELECTRICAL WIRING AND REFRIGERANT LINES BACK TO JUNCTION BOX.
UPPER LEVEL ROOF
ROOF TERRACE BELOW ROOF TERRACE BELOWNO WORK NO WORK
GREENHOUSE INSULATEDGLASS ENCLOSURE BELOW
1 NEW AIR HANDLER MOUNTED ON EXISTING EQUIPMENT PAD. SEE MECHANICAL DRAWINGS. SEE GENERAL ROOF NOTE I.
2 NEW TAPERED STEEL ROOF BEAM OF NEW GREENHOUSE ENLOSURE. SEE SHEETS A-502 AND A-503.
3 NEW STRUCTURAL INSULATED PANEL BETWEEN TAPERED ROOF BEAMS TO EXTENTS SHOWN.
4 NEW "THERMALGAL" TRANSLUCENT INSULATED STRUTRURAL POLYCARBONATE (POLYGAL) SHEET BETWEEN TAPERED ROOF BEAMS TO EXTENTS SHOWN.
5 NEW SKYLIGHT AT EXISTING LOCATION. SIZE TO MATCH EXISTING ROOF OPENING. SEE GENERAL ROOF NOTE I.
6
REPAIR ROOF OPENING. FRAME, INSULATE, AND FINISH TO MATCH EXISTING INTERIOR AND EXTERIOR. SEE GENERAL ROOF NOTE I.7
NEW SAFETY RAIL SOURCE SAFETY ROOF SCREEN INSTALLED ON FRAME OF NEW SKYLIGHT OVER STAIRWELL. SEE GENERAL ROOF NOTE I.
D1
D2
D3
D3
D4
D5
D6
D7
1
2
TYP
3
4TYP
5
56
7
PITCH
PITCH
NEW CONTINUNOUS COIL STOCK ROOF GUTTER WITH COPPER RAIN LEADER PITCHED TOWARD EXISTING ROOF DRAIN.8
8
EXISTING TERRACEDEMISING WALL TO REMAIN
EXISTING PARAPETWALL TO REMAIN
(DO NOT DISTURB)
EXISTING METAL SAFETYRAILING TO REMAIN(DO NOT DISTURB)
EXISTING PARAPETWALL TO REMAIN(DO NOT DISTURB)
8
33
3
3
4
3
2
A-507
2
A-507
1
A-507
TYP
TYP
TYP
1
A-507
TYP
1
A-507
TYP
1
A-507
SIM
OPEN TO ABOVE
L-R1 L-R1
L-R1 L-R1
L-R1L-R1
L-R1 L-R1 L-R1
L-R1 L-R1
L-R1 L-R1 L-R1
L-R1
L-R1L-R1
L-R1L-R1
L-R1
EXPOSED UNDERSIDEOF EXISTING FLOOR
SLAB ABOVE
3
A-507
TYP
3
A-507
TYP
3
A-507
TYP
EXPOSED UNDERSIDE OFEXISTING FLOOR SLAB ABOVE
EXPOSED UNDERSIDE OFEXISTING FLOOR SLAB ABOVE
L-R3L-R3
L-R4 L-R4
L-R2
L-R2
L-R2
L-R2 L-R2 L-R2 L-R2
L-R2
L-R2
L-R2 L-R2 L-R2
L-P2 L-P2 L-P2
L-RL1
L-RL1
WALL MOUNTEDSMOKE DETECTORS(MOUNT 6"-12" FROM
CEILING FINISH)
L-RL1
L-R1
L-R2
L-R2
L-R2
L-RL1
L-RL2
L-RL2 L-RL2
3
U/L 3-WAYSWITCH
L-RL1
RAISED PLATORM BELOW
16' -
8"
8' - 6"
9' - 3"
5' -
0"
1' -
8"
L-RL1
L-RL2
L-WM2
L-WM2
L-WM1
L-WM1
3
A-507L-RL2
L-R2 L-R2
CF-3
CF-3
CF-3 CF-3
CF-3
MOTORIZED CEILING SHADE MOTORIZED CEILING SHADE
CF-2
CF-2
ALIGN
CF-1
CF-1
CF-1
CF-1
CF-1
CF-1CF-5
CF-2
CF-1
L-P1
L-R3 L-R3
L-R
6
L-R
6DR
CF-2
L-WM3
RAISED PLATORM BELOW
2
A-507
TYP
WALL MOUNTED SMOKE DETECTOR(MOUNT 6"-12" FROM CEILING FINISH)
A B
1
L-R5 L-R5
L-R5 L-R5
L-R5 L-R5
L-R1 L-R1 L-R4
L-R4 L-R5
L-R5 L-R5
L-R5
L-R5
L-R5
L-P2L-P2
16' - 9"
L-S1
L-S1
L-S1
L-S1
3
OUT TO TERRACE
4
4
4
L-RL2
T
M/L 3 WAY SWITCHL-TL1M/L 3 WAY SWITCH
MASTER BED CUSTOMCASEWORK BELOW
L-RL2
TREADBELOW
L-RL1
EXPOSED UNDERSIDE OFEXISTING SLAB ABOVE
CF-3
STEEL BEAMTYP
4
A-507
CF-1
CF-1
CF-1
CF-1
L-R6
L-R6
L-R6
L-R6
L-R6
L-R6
L-R
6
L-R
6
CF-1
DR
DR
DR
DR
DR
L-R
6
L-R
6
CF-1
CF-1
L-P2
L-WM4 CF-1
CF-6
CASEWORKBELOW
L-S2 L-S2 L-S2 L-S2 L-S2 L-S2 L-S2
L-WM5
4
A-507
TYP
TYP
CF-6CF-6CF-6 CF-6 CF-6 CF-6
L-TL1
WALL MOUNTED SMOKE DETECTOR(MOUNT 6"-12" FROM CEILING FINISH)
4
4
4
L-WM6 L-WM6
SINGLE POLE WALL MOUNTED SWITCH
SYMBOL DESCRIPTION
ELECTRICAL LIGHTING LEGEND
3 WAY WALL MOUNTED SWITCH
4 WAY WALL MOUNTED SWITCH
JAMB MOUNTED DOOR SWITCHDR
1" RECESSED LED
4" RECESSED HALOGEN
4" RECESSED LED (SHOWER)
WALL MOUNTED SCONCE
CEILING MOUNTED TRACK LIGHTING
WALL MOUNTED SURFACE FIXTURE
ROPE LIGHT
CEILING MOUNTED SURFACE FIXTURE
PENDANT MOUNTED LIGHT FIXTURE
CEILING MOUNTED SURFACE FIXTURE
Scale:
ConsultantContactAddress
Phonee-mail
ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523
www.wilkinsonarchitects.com
New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561
National Council of Architectural Registration Board #52853
DOB Barcode
ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY 10001212.929.2491Ilya@atozengineers.com
ConsultantContactAddress
Phonee-mail
NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY 11372646-522-0589rhanna@engineer.com
MECHANICAL
STRUCTURAL
1/4" = 1'-0"
A-103
REFLECTED CEILING PLANS
ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021
04/03/2015
1/4" = 1'-0"1
Penthouse F - 36th Flr - Main LevelReflected Ceiling Plan
1/4" = 1'-0"2
Penthouse F - Upper Level RefelectedCeiling Plan
No. Description Date
LIGHTING FIXTURE SCHEDULEDesig. Cnt Description Housing / Trim Lamp Manufacturer Product ID Location(s)L-P1 1 PENDANT MOUNTED (OWNER PROVIDED) NA INCANDESCENT 1ST FLR: DININGL-P2 3 PENDANT MOUNTED (OWNER PROVIDED) NA T5 Delray Lighting 6311 2MD FLR: STAIRWELLL-R1 23 LOW VOLTAGE HALOGEN TRIMLESS HALOGEN (12OV, 277V, OR 347V) USAI 9004-10-C-FL100-120 1ST FLR: FOYER/LIVING/DINING SOFFITSL-R2 17 LOW VOLTAGE HALOGEN 4" LOW VOLTAGE REMODEL HOUSING MR16 (12V/50W) WAC LIGHTING HR-8401E 1ST FLR: LIVING/DINING & KITCHEN DROP CEILINGL-R3 4 1" LEDme MINI RECESSED ADJUSTABLE SPOT NA / LOW PROFILE TRIM WARM/NEUTRAL LED (3W) WAC LIGHTING HR-LED272R 1ST FLR: POWDER ROOM CEILINGL-R4 4 4" LEDme NEW CONSTRUCTION HOUSING / SHOWER TRIM 6 x WARM/NEUTRAL LED (3W) WAC LIGHTING HR-LED418-N 1ST FLR: BATHROOM SHOWER CEILING 2ND FLR: MASTER BATHROOM SHOWER CEILINGL-R5 12 3.5" TESLA LED NA / DOWNLIGHT TRIM LUXEON S MULTI-CHIP LED (18W) WAC LIGHTING HR-3LED-T718 2ND FLR: STAIRWELL CEILING, HALL CEILING, MASTER BEDROOM DROP CEILINGL-R6 12 1" LEDME MINI RECESSED ADJUSTABLE SPOT NA / LOW PROFILE TRIM WARM/NEUTRAL LED (3W) WAC LIGHTING HR-LED272R 1ST FLR: BEDROOM CLOSET CLG 2ND FLR: W/D CLG, ELEC CLOSET CLG, M. BEDROOM CLOSET CLGL-S1 3 SURFACE MOUNTED (OWNER PROVIDED) 2ND FLR: MASTER BEDROOM DROP CEILINGL-S2 7 SURFACE MOUNTED (OWNER PROVIDED) 2ND FLR: GREENHOUSE BAY CEILINGSL-TL1 1 14' LED TRACK LIGHTING (OWNER PROVIDED) 2ND FLR: MASTER BEDROOM CEILING (WEST)
L-WM1 2 WALL MOUNTED (OWNER PROVIDED) 1ST FLR: POWDER ROOM (BEHIND MIRROR)L-WM2 2 WALL MOUNTED (OWNER PROVIDED) 1ST FLR: BATHROOM (ABOVE MIRROR)L-WM3 1 WALL MOUNTED (OWNER PROVIDED) 1ST FLR STAIRWELL (WALL MOUNTED ABOVE STAIR PLATFORM)L-WM4 1 WALL MOUNTED (OWNER PROVIDED) 2ND FLR: MASTER BATHROOM (WALL MOUNTED W/ MIRROR SURROUND)L-WM5 1 WALL MOUNTED (OWNER PROVIDED) 2ND FLR: MASTER BEDROOM (WALL MOUNTED)L-WM6 2 WALL MOUNTED (OWNER PROVIDED) 2ND FLR: MASTER BEDROOM (WALL MOUNTED)
FF-1
FF-1
FF-1
FF-3
FF-2
FF-2
FF-2
FF-2
FF-6
FF-6
2
A-505
2
A-505
1
A-505
1
A-505
6
A-505
2' -
7 1
/4"
2' -
4 3
/4"
1' - 7" 3' - 4"
A B
1
FF-4FF-4
FF-5
FF-6
FF-5
FF-5
FF-24
A-505
1
A-302
7
A-505
FLOOR FINISH SCHEDULEDESIGNATION SIZE/MATERIAL FINISH MANUFACTURER LOCATION(S)
FF-1 3/8"x12"x24" PORCELAIN FLR TILE MATTE NASCO STONE & TILE
SERIES/COLOR
FUSSION, DARK ANTHRACITE
FF-3
3/8"x6"x24" PORCELAIN FLR TILE MATTE PROVENZAW-AGE, CORTEX NERO
FF-5 3/4" VENEERED PLYWOOD FLOOR SATIN CLEAR TBDEAST INDIAN ROSEWOOD
1ST FLR: FOYER, LIVING, DINING, KITCHEN, BEDROOM, BATHROOM
FF-6 3/4" SOLID WOOD RUBBED MONOCOAT MATTEWALNUT 1ST FLR: STAIR TREADS, KITCHEN CUSTOM CASEWORK
2ND FLR: MASTER BEDROOM, MASTER BATHROOM, GREENHOUSE
2ND FLR: MASTER BATHROOM & SHOWER
FF-2 3/8"x40"x40" PORCELAIN FLR TILE MATTE NASCO STONE & TILEFUSSION, DARK ANTHRACITE 1ST FLR: POWDER RM
FF-4
3/8"x6"x36" PORCELAIN WALL TILE MATTE DALTILEACACIA VALLY, ASH 1ST FLR: BATHROOM SHOWER
TBD
REMARKS
FIELD CUT AS NOTED IN PLAN
Scale:
ConsultantContactAddress
Phonee-mail
ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523
www.wilkinsonarchitects.com
New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561
National Council of Architectural Registration Board #52853
DOB Barcode
ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY 10001212.929.2491Ilya@atozengineers.com
ConsultantContactAddress
Phonee-mail
NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY 11372646-522-0589rhanna@engineer.com
MECHANICAL
STRUCTURAL
As indicated
A-104
FLOOR FINISHES PLANS
ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021
04/03/2015
1/4" = 1'-0"1
Penthouse F - 36th Floor - Main Level FloorFinishes Plan
1/4" = 1'-0"2
Penthouse F - Upper Level Floor FinishesPlan
No. Description Date
FLOOR TILE EXTENDSBENEATH TOE KICK
A-202 4
1
3
-
2
6
A-202
AP-1
-
---
1
A-506
2' - 2"
ALIGN
ALIGN
AP-2
WOOD PANEL
MARINE EDGE SS-1
SS-1
CT-1
CT-1
AP-3
5
A-202
8
A-202 4
1
3
2
- -
ROLL OUT
SH
ELF
PULL OUT
PULL OUT
DRAWER
AP-1
AP-5SINK BASIN
AP-4
AP-3
DRAWERSHELFALIGN
-
---
1
A-506
STEEL ANGLE SUPPORTBENEATH FLOATING CABINETS
COUNTERTOP ABOVE
EXISTING CASTIRON RADIATOR
RECESSED TOE KICK
5
A-202
8
A-202 4
1
3
-
2
6
A-202
FC
U-1
EN
CLO
SU
RE
FC
U-1
UNISTRUT(TYP)
HOOD DUCT
DRAWER
DRAWER
-
---
1
A-506
9' - 3"
L-R1
L-R1
L-R1
L-R1
L-R1
L-R1
L-R1
L-R1
L-R1
GLASS SHELF
GL-1
GL-1
CW-1CW-1
5
A-202
Scale:
ConsultantContactAddress
Phonee-mail
ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523
www.wilkinsonarchitects.com
New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561
National Council of Architectural Registration Board #52853
DOB Barcode
ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY 10001212.929.2491Ilya@atozengineers.com
ConsultantContactAddress
Phonee-mail
NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY 11372646-522-0589rhanna@engineer.com
MECHANICAL
STRUCTURAL
1" = 1'-0"
A-201
KITCHEN ENLARGED PLANS
ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021
04/03/2015
1" = 1'-0"2
Penthouse F - 36th Floor - Main LevelKitchen Enlarged Plan
1" = 1'-0"1
Penthouse F - 36th Floor - Main LevelKitchen Enlarged Plan (Base)
1" = 1'-0"3
Penthouse F - 36th Floor - Main LevelKitchen Enlarged Plan (Upper)
No. Description Date
T ecton ic Cop yright 2007
T ecton ic Cop yright 2007
AP-4 AP-5
AP-2
AP-1
1/2" 2' - 0" 3/4" 2' - 3" 3/4" 2' - 3" 3/4" 2' - 6" 1' - 11 1/2" 5 1/2"
-
---
CW-1 CW-1 CW-1
CW-1CW-1
CW-1
CW-1
GFI
CW-1CT-1 CT-1
5
A-202
EXISTING CAST IRONRADIATOR BEYOND
AUTOMATIC ROLLER SHADE
L-R1 L-R1 L-R1
7 3/
4"11
1/2
"1'
- 3
1/2
"1
1/2"
5' - 10"
EXISTINGCONCRETE
COLUMNEXPOSED
AP-4CW-1
CW-1CW-1
CW-1
EXISTING CAST IRONRADIATOR BEYOND
EQ EQ EQ EQ EQ
CT-1
3' -
0"
2-1/2"x2-1/2"x3/16" STEEL ANGLE
UNISTRUT SUPPORTS (TYP)
L-R1L-R1L-R1
AP-4
1
A-506A-202
6
CW-2 CW-2
CW-2CW-2
CW-2
CW-2
CW-2
4
A-506
CW-1
GL-1 GL-1
SS-1
EXISTING CONCRETECOLUMN EXPOSED
CT-1
6
A-202
AP-1
AP-2
1 1/2" 7 1/2" 2' - 6" 7 1/2" 1 1/2" 2' - 6" 1 1/2"
AP-3
RECIRCULATING HOOD DUCT
GFI GFI
FCU-1 UNIT
EXHAUST DUCTFCU-1 UNIT
CW-1
CW-1
CW-1
SS-1
GFI
CW-1 CW-1
WF-1
SS-1 SS-1
A-2025
CW-1
CW-1 CW-1
CW-1
L-R1 L-R1 L-R1
10 3
/4"
2' -
1 1
/2"
6"
1 1/
2"
FCU-1
HOOD
DU
CT
DUCT DUCT
UNISTRUT
UNISTRUT
AP-2
DRAWER
VE
NT
5" M
IN.
CT-1
TOE KICK VENT
EXISTING CASTIRON RADIATOR
1 1/
2"
1/8" EASED EDGE(TYP)
RECESSED PULL
SHELF
IN FRONT OF RADIATORSHALLOW CABINET ONLY
SHELF
Scale:
ConsultantContactAddress
Phonee-mail
ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523
www.wilkinsonarchitects.com
New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561
National Council of Architectural Registration Board #52853
DOB Barcode
ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY 10001212.929.2491Ilya@atozengineers.com
ConsultantContactAddress
Phonee-mail
NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY 11372646-522-0589rhanna@engineer.com
MECHANICAL
STRUCTURAL
As indicated
A-202
KITCHEN ELEVATIONS
ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021
04/03/2015
1" = 1'-0"1 Kitchen Elevation - North
1" = 1'-0"3 Kitchen Elevation - West
1" = 1'-0"2 Kitchen Elevation - South
1" = 1'-0"4 Kitchen Elevation - East
1" = 1'-0"6 Range/Hood/FCU-1 Section
No. Description Date
1 1/2" = 1'-0"5 Kitchen Recessed Casework Section
A-203
12
13
14
15
SHELF
SH
ELF
FF-4FF-4
PL-7
PL-11
A-20310
7
8
9
FF-1
FF-3
A-203
4
3
2
5
FF-2
FF-2
FF-2
FF-6
CT-3
PL-5
PL-10
MR-1
P-1
MEDICINECABINET
WF-3
WF-3
WF-3CT-3
MR-1
WF-1
A-5056
P-1
WF-3
WF-3GFI
CT-3
L-R4
L-WM2 L-WM2
PL-10
PL-6
SLIDE
WF-1
A-5056
P-1
3
L-R4
WF-3
7
G2
WF-1
FF-1
PL-6
CF-1
WF-3
SLIDE
MIRROR
A-5056
P-2
5
FF-4 FF-4
P-2
MR-1
8 G3
FF-4
TRANSOM WINDOW7' - 8"
MR-1
WF-3
MR-1
A-5056
WF-4
WF-4
SS-1
CT-2
CT-2
G3
P-2 P-2
FF-4
L-WM4
MR-1 MR-1
MR-1
SS-1
CW-3
CW-3
CW-3
WF-4
WF-3
WF-4
MR
-1
L-WM4
WC-1
WF-2
WF-2
CT-3
L-WM1
MR-1
WC-1
WF-2 MR-1
CT-3
L-WM1 L-WM1
P-1
WF-4
PL-10
PL-5CW-3
WF-4WF-4
WF-4
WF-4WF-4WF-4
CT-3
L-WM1MR-1
SLIDE
WF-2
G1
WC-1
WF-4
1
Scale:
ConsultantContactAddress
Phonee-mail
ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523
www.wilkinsonarchitects.com
New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561
National Council of Architectural Registration Board #52853
DOB Barcode
ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY 10001212.929.2491Ilya@atozengineers.com
ConsultantContactAddress
Phonee-mail
NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY 11372646-522-0589rhanna@engineer.com
MECHANICAL
STRUCTURAL
1/2" = 1'-0"
A-203
BATHROOM ENLARGED PLANS &ELEVATIONS
ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021
04/03/2015
1/2" = 1'-0"11
Penthouse F - Upper Level Master BathEnlarged Plan
1/2" = 1'-0"6
Penthouse F - 36th Floor - Main Level BathEnlarged Plan
1/2" = 1'-0"1
Penthouse F - 36th Floor - Main LevelPowder Room Enlarged Plan
1/2" = 1'-0"7 Bathroom Elevation - North
1/2" = 1'-0"8 Bathroom Elevation - East
1/2" = 1'-0"10 Bathroom Elevation - West
1/2" = 1'-0"9 Bathroom Elevation - South
1/2" = 1'-0"12 Master Bath Elevation - North
1/2" = 1'-0"13 Master Bath Elevation - East
1/2" = 1'-0"14 Master Bath Elevation - South
1/2" = 1'-0"15 Master Bath Elevation - West
1/2" = 1'-0"2 Powder Elevation - North
1/2" = 1'-0"3 Powder Elevation - East
1/2" = 1'-0"4 Powder Elevation - South
1/2" = 1'-0"5 Powder Elevation - West
No. Description Date
PL-6
PL-10
A-2045 3
4
2
3' -
0"
3' -
0"
1' -
6"
1' -
4 3
/4"
S/D
C1
P-2
P-2
SLIDE
3
S/D
P-2
P-2
P-2
7"6'
- 6
3/4
"2'
- 4
"
ATUO ROLLER SHADE POCKET BEYOND
PTAC UNIT
EXISTING SLIDING WINDOW
2' - 6" 3' - 5" 2' - 6"
CW-1 CW-1
CW-1
CW-1 CW-1
P-2
P-2
WB-1
8' - 8" 8' - 3" 4' - 4"
1' -
7"
1' -
5"
1' -
6 3
/4"
1' -
6 3
/4"
1' -
8 1
/2"
SLIDE
60" FLAT SCREEN TV
2
3' - 6 3/4"
P-2P-2
P-2
P-2
CW-5
CW-5
CT-5
PTACUNIT
CT-5
L-R2L-R2L-R2
CW-5CW-5
A-204
7
8
9
10
14' -
3"
1' -
0"
4' -
2 3
/4"
1' -
0"
6' -
6"
1' -
0"
2' -
6"
8' - 6" 3' - 0"
5' -
2 3
/4"
6' -
6" A-5067
A-506 6
4
A-507
EXG SLIDING WINDOW
L-TL1
L-WM6 L-WM6
BED FRAMEBY OWNER
P-3
P-3
MASTERCLOSET
P-3
A-5065
A-5074
OPP
L-R5 L-R5 L-S1
SLIDESLIDE
S/D L-WM5
4 5
P-3
P-3
L-TL1
P-3
ACCESS TOW/D SHUTOFFS
MASTERCLOSET
L-R5 L-R5L-S1
A-5074
TYP
A-5074TYP
A-5074 OPP
S/D
C4C4C4
P-3
L-S1 L-S1 L-S1
P-3 P-3 P-3
EXISTING SLIDING WINDOW
L-TL1
EXISTING FLUE & COVER
L-TL1
P-3
P-3
P-3
WB-1
UPHOLSTERED CUSION
PTAC UNIT
CW-3
Scale:
ConsultantContactAddress
Phonee-mail
ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523
www.wilkinsonarchitects.com
New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561
National Council of Architectural Registration Board #52853
DOB Barcode
ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY 10001212.929.2491Ilya@atozengineers.com
ConsultantContactAddress
Phonee-mail
NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY 11372646-522-0589rhanna@engineer.com
MECHANICAL
STRUCTURAL
1/2" = 1'-0"
A-204
BEDROOM ENLARGED PLANS &ELEVATIONS
ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021
04/03/2015
1/2" = 1'-0"1
Penthouse F - 36th Floor - Main LevelBedroom Enlarged Plan
1/2" = 1'-0"4 Bedroom Elevation - South
1/2" = 1'-0"3 Bedroom Elevation - East
1/2" = 1'-0"2 Bedroom Elevation - North
1/2" = 1'-0"5 Bedroom Elevation - West
1/2" = 1'-0"6
Penthouse F - Upper Level Master BedroomEnlarged Plan
1/2" = 1'-0"7 Master Bedroom Elevation - North
1/2" = 1'-0"9 Master Bedroom Elevation - South
1/2" = 1'-0"8 Master Bedroom Elevation - East
1/2" = 1'-0"10 Master Bedroom Elevation - West
No. Description Date
A-2053
2
AP-6
AP-6
P-1
CW-3 MR-1
CW-1
L-R2 L-R2 L-R2
A-5073OPP
AP-6
EXISTINGENTRY DOOR
OUTSIDE CORNEROF POWER RM WALL
WC-2
WC-2WC-2
CW-4
WF-5
WF-5
WF-5
WF-5
WB-1
L-R2L-R2L-R2 L-R2L-R2
A-5073 TYP
1
A-507
EXISTING WOODBURNING FIREPLACE
AND MANTEL
P-1
CW-4PTAC UNIT PTAC UNIT
CW-4 CW-4
P-1
EXISTING SLIDING WINDOW EXISTING SLIDING WINDOW
A-5072
TYP
A-5072
OPP
WB-1 WB-1
L-R1 L-R1 L-R1 L-R1 L-R1L-R2
CT-4 CT-4
WF-6 WF-6
EXISTING SLIDING DOOR
SLIDE
FLUE
L-P1
RACEWAY FORL-P1 WIRING
P-1
L-R1L-R1
A-5072
TYP
A-5072OPP
PTAC ENCLOSURE BEYOND
4
A-303
2
SLIDE
4
A-506
ROLL OUT
ROLL OUT
CW-1CW-2
CW-1
CW-1
P-1
P-1
P-1
P-1
L-P2
EXISTINGCONCRETE
COLUMNEXPOSED
Scale:
ConsultantContactAddress
Phonee-mail
ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523
www.wilkinsonarchitects.com
New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561
National Council of Architectural Registration Board #52853
DOB Barcode
ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY 10001212.929.2491Ilya@atozengineers.com
ConsultantContactAddress
Phonee-mail
NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY 11372646-522-0589rhanna@engineer.com
MECHANICAL
STRUCTURAL
1/2" = 1'-0"
A-205
MAIN FLOOR ENLARGED PLANS &ELEVATIONS
ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021
04/03/2015
1/2" = 1'-0"1
Penthouse F - 36th Floor - Main Level FoyerEnlarged Plan
1/2" = 1'-0"3 Foyer Elevation - West
1/2" = 1'-0"2 Foyer Elevation - South
No. Description Date
1/2" = 1'-0"6 Living/Dining Elevation - West
1/2" = 1'-0"5 Living/Dining Elevation - North
1/2" = 1'-0"8 Living/Dining Elevation - East
A-206
5
4
2
3
FC
U-2
3' - 2 1/4"
2' -
6"
4' -
5"
2' -
6"
2
A-302
6 3/
4"9'
- 1
1"
A B
1
3' - 2" 3' - 2" 3' - 2" 3' - 2" 3' - 2" 11"
PL-9
PL-13
AP-9
CT-3
FF-5
FF-5
CT-3
8 1/
4"
3/4"
8 1/
4"
3/4"
8 1/
4"
3/4"
1' -
5"
AP-10
3' - 8"TRANSOM WINDOW TO MASTER BATHROOM
7' - 8"1' - 10 1/4"
A B
6
W2MR-1
PL-9
WB-1WB-1
P-4
P-4
P-4
ACCESS TO MASTERBATHROOM CLEAN OUT
FCU-2
PL-13
MR-1
1' -
3 1
/2"
MATCH FINISH MATCH FINISHS/D
AP-9
AP-10
2' - 1 1/2"1 1/2"
MR-1
P-4
P-4
CW-1
CW-1
PL-13
PL-9
P-4
CW-1
CT-3
FCU-2
WF-4
1
W2
W2
W2
WB-1
P-4P-4
AB
W1 W1W1 W19
FCU-2
WF-4 WF-4 WF-4 WF-4 WF-4 WF-4 WF-4
STEEL ROOF BEAM(TYP)
STEEL ROOF BEAM(TYP)
CF-6(TYP)
CF-6(TYP)
CF-6(TYP)
Scale:
ConsultantContactAddress
Phonee-mail
ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523
www.wilkinsonarchitects.com
New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561
National Council of Architectural Registration Board #52853
DOB Barcode
ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY 10001212.929.2491Ilya@atozengineers.com
ConsultantContactAddress
Phonee-mail
NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY 11372646-522-0589rhanna@engineer.com
MECHANICAL
STRUCTURAL
3/4" = 1'-0"
A-206
GREENHOUSE ENLARGED PLAN &ELEVATIONS
ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021
04/03/2015 3/4" = 1'-0"
1
Penthouse F - Upper Level GreenhouseEnlarged Plan
3/4" = 1'-0"2 Greenhouse Elevation - North
3/4" = 1'-0"3 Greenhouse Elevation - East
3/4" = 1'-0"4 Greenhouse Elevation - West
3/4" = 1'-0"5 Greenhouse Elevation - South
No. Description Date
P-4
GF
I
FC
U-2
2
A-302
TYP
2' - 3" 2' - 3" 2' - 3" 2' - 3" 2' - 3" 2' - 3" 2' - 3"
HSS 5x5
x1/2
HSS 5x5
x1/2
6" 15' - 9" 6"
3/8"
TH
ICK
TA
PE
RE
D S
TE
EL
BE
AM
(T
YP
OF
8)
3/8"
TH
ICK
TA
PE
RE
D S
TE
EL
BE
AM
(T
YP
OF
8)
A B
1
2' -
0"
10' -
2 1
/2"
1
A-302
17' - 3 3/4"
3/8"
TH
ICK
TA
PE
RE
D S
TE
EL
BE
AM
(T
YP
OF
8)
3/8"
TH
ICK
TA
PE
RE
D S
TE
EL
BE
AM
(T
YP
OF
8)
3/8"
TH
ICK
TA
PE
RE
DS
TE
EL
BE
AM
(T
YP
OF
8)
3/8"
TH
ICK
TA
PE
RE
DS
TE
EL
BE
AM
(T
YP
OF
8)
3/8"
TH
ICK
TA
PE
RE
DS
TE
EL
BE
AM
(T
YP
OF
8)
3/8"
TH
ICK
TA
PE
RE
DS
TE
EL
BE
AM
(T
YP
OF
8)
3/8"
TH
ICK
TA
PE
RE
DS
TE
EL
BE
AM
(T
YP
OF
8)
3/8"
TH
ICK
TA
PE
RE
DS
TE
EL
BE
AM
(T
YP
OF
8)
Scale:
ConsultantContactAddress
Phonee-mail
ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523
www.wilkinsonarchitects.com
New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561
National Council of Architectural Registration Board #52853
DOB Barcode
ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY 10001212.929.2491Ilya@atozengineers.com
ConsultantContactAddress
Phonee-mail
NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY 11372646-522-0589rhanna@engineer.com
MECHANICAL
STRUCTURAL
1" = 1'-0"
A-301
GREENHOUSE FRAMING PLAN
ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021
04/03/2015
No. Description Date
1" = 1'-0"1
Penthouse F - Upper Level GreenhouseEnlarged Framing Plan
EXISTING TERRACE DRAIN(DO NOT DISTURB)
EXISTING ROOF ASSEMBLY
EXISTING SLEEPERS
EXISTING RIGID INSULATION
EXISTING PLYWOOD SUB-FLOOR
NEW BACKERBOARD
NEW STONE TILE FLOORING
EXISTING CMU KNEE WALLMODIFIED IN HEIGHT
EXISTING ROOF MEMBRANENOT TO BE DISTURBED
EXISTING PAVER SYSTEM(NO WORK)
NEW 3/8" STEEL BEAM
INTERIOR EXTERIORGREENHOUSE
EXISTING PARAPET FLASHING CAP TO REMAIN
NEW PLUMBING RUN ABOVESLAB TO EXISTING RISERCONCEALED BENEATH STEP
SOPREMA WATERPROOFING MEMBRANE(COLOR TO BE WHITE)
6-1/2" R-30 SIP PANEL
POLYGAL "THERMOGAL"THERMALLY INSULATEDSTRUCTURAL POLYCARBONATEPANEL (0.31 U VALUE)
NEW SKYLINE TERRACEDOOR (OUTSWING)
3/8" STEEL BEAM
LATICRETE 9235 WATERPROOFINGMEMBRANE APPLIED IN (2) LAYERS WITH
REINFORCEMENT FLEECE IN BETWEEN
A-5033
A-5034
A-5035
A-5032
A-5031
A-5054
TYP
OPEN
EX
IST
ING
OP
EN
ING
EXTENT OF EXISTING GREENHOUSE TO BE REMOVED
SILL FLASHING END DAMAT WALL BEYOND (TYP)
HSS 5X5X1/2 COLUMN INWALL BEYOND
ALUMINUM STOREFRONT SYSTEM
GRACE VYCOR SILL FLASHING
GRACE VYCOR-NER END DAMSILL FLASHING BEYOND
BASF SONOLASTIC 150 EXTERIORCAULK (COLOR TO MATCH EXTERIOR
FINISHES PENDING BOARD APPROVAL)
EXTERIOR SHEATHING
SOLARBAN 60 LOW E INSULATED GLASS
R7.5 CONTINUOUS RIGID INSULATION
ALUMINUM SILL PAN
STUCCO EXTERIOR FINISH
R13 BATT INSULATION
CEMENT BACKERBOARD
LATICRETE 9235 WATERPROOFINGMEMBRANE APPLIED IN (2) LAYERS WITH
REINFORCEMENT FLEECE IN BETWEEN
3/8" STONE TILE
UNMODIFIED THINSET MORTER
5/8" PLYWOOD SUBFLOOR
EXISTING 2" RIGIDINSULATION
EXISTING ROOFASSEMBLY
EXISTING SLEEPERJOISTS
WATERPROOFSEALANT
1/8" THICK WOODFILLER
EXISTING CMU KNEE WALLMODIFIED IN HEIGHT
EXISTING PAVER SYSTEM(NO WORK)
P.T. WOOD BLOCKING
PAN FLASHINGWITH DRIP EDGE
3/8" BACKER RODAND CAULK
QT SCU PERIMETER ISOLATION STRIP
UV BLOCKING WINDOW FILM
5/8" GYPSUMWALL BOARD
SOLID WOOD SILL
SOLID WOOD TRIM
5/8" PLYWOOD
HSS 3x1-1/2x3/8
3/8" STEEL BEAM
3/8" STEEL TABWELDED TO BEAM
6-1/2" R30 SIPS PANEL
ALUMINUM STOREFRONT SYSTEM
ALUMINUM STOREFRONT SYSTEM
BASF SONOLASTIC 150 EXTERIOR CAULK(COLOR TO MATCH EXTERIOR FINISHES
PENDING BOARD APPROVAL)
ALUMINUM SILL PAN
1" THICK AZEK TRIM
BASF SONOLASTIC 150 EXTERIORCAULK (COLOR TO MATCH EXTERIOR
FINISHES PENDING BOARD APPROVAL)
5/8" PLYWOOD
GRACE VYCOR-NER END DAMSILL FLASHING BEYOND
SOLARBAN 60 LOW E INSULATED GLASS
UV BLOCKING WINDOW FILM
BASF SONOLASTIC 150 EXTERIOR CAULK(COLOR TO MATCH EXTERIOR FINISHES
PENDING BOARD APPROVAL)
1" THICK AZEK FACIA3/4" MDF NOTCHEDAROUND STEEL TAB
WHITE SOPREMAWATERPROOF MEMBRANE
COIL STOCK FLASHING WITH DRIP EDGE(MIN 0.05 GAUGE)
EXTERIOR GREEN-HOUSE
A
A
A
BEAM
BEAM
ALUMINUM STOREFRONT SYSTEM
Scale:
ConsultantContactAddress
Phonee-mail
ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523
www.wilkinsonarchitects.com
New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561
National Council of Architectural Registration Board #52853
DOB Barcode
ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY 10001212.929.2491Ilya@atozengineers.com
ConsultantContactAddress
Phonee-mail
NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY 11372646-522-0589rhanna@engineer.com
MECHANICAL
STRUCTURAL
As indicated
A-302
GREENHOUSE SECTIONS
ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021
04/03/2015
No. Description Date
1 1/2" = 1'-0"1 GREENHOUSE SECTION
3" = 1'-0"2 GREENHOUSE WEST WALL F.H. SECTION
A-5012
TYP
12
13
14
15
16
17
A-5022
1
A-502
TYP
L-P1
L-P1
L-P1
SKYLIGHT OPENING
1
A-501
TYP
1
2
3
4
5
6
7
8
9
10
11
ROPE LIGHTL-RL1
A-5058
3/16"x1/4" STEELBAR STOCK (TYP)
1/2"x1-1/2" STEELBAR STOCKHANDRAIL
4
A-303
2
A-501
1
A-501
TYP
1 2 3 4 5 6 7
8
10
9
11
12
13
151617 14
UP
1
A-502
TYP
2
A-502
3
A-303
FF-6(TYP)
CW-1
EXISTING W8 x 13
NEW DOUBLE JOIST
NEW DOUBLE JOIST
EXISTING W8 x 13
EXISTING W8 x 13
EX
IST
ING
W8
x 13
4
A-303
1
A-501
2
A-501
TYP
1
2
3
4
5
6
7
8
1 3/
4"3'
- 1
1 1/
4"2'
- 0
"1'
- 6
"1
3/4"
1' -
2"
1' -
0"
1' -
0"
1' -
0"
2 1/
4"
1' -
8"
ROPE LIGHTL-RL1
1
A-506
2' - 11 1/4"2' - 11"
A-5058
SIM
GL-1
4
A-506
T.O. GLASS SHELF
T.O. GLASS SHELF
T.O. GLASS SHELF
T.O. GLASS SHELF
Scale:
ConsultantContactAddress
Phonee-mail
ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523
www.wilkinsonarchitects.com
New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561
National Council of Architectural Registration Board #52853
DOB Barcode
ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY 10001212.929.2491Ilya@atozengineers.com
ConsultantContactAddress
Phonee-mail
NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY 11372646-522-0589rhanna@engineer.com
MECHANICAL
STRUCTURAL
1" = 1'-0"
A-303
STAIRWELL PLANS & SECTIONS
ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021
04/03/2015 1" = 1'-0"4 STAIRWELL SECTION LOOKING SOUTH
No. Description Date
1" = 1'-0"1
Penthouse F - 36th Floor - Main LevelStairwell Enlarged Plan
1" = 1'-0"2 ROOF FRAMING ABOVE STAIRWELL
1" = 1'-0"3 STAIRWELL SECTION LOOKING NORTH
SELF TAPPING MACHINE SCREWS
BOTTOM OF EXISTING CONCRETE ROOF SLAB
1/2" x 3/16" STEEL SUPPORT TABS
8" x 2" 10 GAUGE UNPUNCHED COLD FORM JOIST (TYP)
5/8" EXPANSION BOLT (BASE PLATE ANDBOLT CONCEALED BEHIND FINISHED GWB)
EXISTING WALL ASSEMBLY
8"
BUILT-UP SOLID WOOD STAIR TREAD3'-3" WIDE (VERIFY IN FIELD)
1 1/
4"3
1/2"
1 1/
4"
SP
LIC
E6"
5/8" TYPE X FIRE RATED GYPSUM WALL BOARD
PLASTIC J-BEAD
1/2" x 3/16" STEEL BARSTOCK WITH BRASS FINISH
WELD (TYP)
1" x 1" x 1/8" STEEL TUBE WELDED TO PLATE
1/2" GYPSUM WALL BOARDWITH PLASTER SKIM COAT
3" x 11" x 1/8" THICK STEEL PLATEFASTENED TO WALL
COUNTERSUNK SQUAREDRIVE BOLTS (TYP)
1/2" x 3/16" STEEL BARSTOCK WITH BRASS FINISH
1/2" x 3/16" STEEL BARSTOCK WITH BRASS FINISH
3/4" 3 1/4" 3 1/4" 3/4"WELDED CONNECTION(FILED DOWN FORSMOOTH FINISH)
5/8" GYPSUM WALL BOARD ENCLOSURE
EXISTING WALL ASSEMBLY
OPEN TO SKYLIGHT ABOVEEXISTING SKYLIGHTWALL ASSEMBLY
BRIDGE JOISTS WITHSTEEL STRAP @ 16" O.C.
SOLID FIRE TREATED WOODBLOCKING BETWEEN HEAVYGAUGE JOISTS
EXISTING CONCRETE ROOF SLAB
EXISTING W8 x 13
6" S
PLI
CE
1/2" x 3/16" STEELSUPPORT TABS
(2) 8" x 2" 10 GAUGE UNPUNCHEDCOLD FORM JOIST (TYP)
5/8" EXPANSION BOLT (BASEPLATE AND BOLT CONCEALEDBEHIND FINISHED GWB)
1/2" x 3/16" STEELBAR STOCK (TYP)
1 1/
4"3
1/2"
1 1/
4"
1" x 1" x 1/8" STEEL TUBE (2 PER TREAD)
ST
AIR
TR
EA
D2
1/2"
TH
ICK
MA
XIM
UM
OP
EN
ING
3"7 51
/128
"
1/2" x 3/16" STEELBAR STOCK (TYP)
8 3/4"
COUNTERSUNK SQUAREDRIVE BOLTS (TYP)
3" x 11" x 1/8" STEELPLATE BEYOND
3" x 11" x 1/8" STEELPLATE BEYOND
Scale:
ConsultantContactAddress
Phonee-mail
ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523
www.wilkinsonarchitects.com
New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561
National Council of Architectural Registration Board #52853
DOB Barcode
ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY 10001212.929.2491Ilya@atozengineers.com
ConsultantContactAddress
Phonee-mail
NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY 11372646-522-0589rhanna@engineer.com
MECHANICAL
STRUCTURAL
6" = 1'-0"
A-501
STAIR DETAILS I
ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021
04/03/2015
No. Description Date
6" = 1'-0"1 STAIR TREAD SUPPORT DETAIL 1
6" = 1'-0"2 STAIR TREAD SUPPORT DETAIL 2
SELF TAPPING MACHINE SCREWS
BOTTOM OF EXISTING CONCRETE ROOF SLAB
1/2" x 3/16" STEEL SUPPORT TABS
8" x 2" 10 GAUGE UNPUNCHED COLD FORM JOIST (TYP)
5/8" EXPANSION BOLT (BASE PLATE ANDBOLT CONCEALED BEHIND FINISHED GWB)
EXISTING WALL ASSEMBLY
8"
BUILT-UP SOLID WOOD STAIR TREAD3'-3" WIDE (VERIFY IN FIELD)
ST
AIR
TR
EA
D2
1/2"
TH
ICK
1 1/
4"3
1/2"
1 1/
4"
SP
LIC
E6"
5/8" TYPE X FIRE RATED GYPSUM WALL BOARD
PLASTIC J-BEAD
1/2" x 3/16" STEEL BAR STOCKWITH BRASS FINISH
WELD (TYP)
1" x 1" x 1/8" STEEL TUBE
1/2" GYPSUM WALL BOARDWITH PLASTER SKIM COAT
COUNTERSUNK SQUAREDRIVE BOLTS (TYP)
1/2" x 3/16" STEEL BARSTOCK WITH BRASS FINISH
1/2" x 3/16" STEEL BARSTOCK WITH BRASS FINISH
3/4" 3 1/4" 3 1/4" 3/4"WELDED CONNECTION(FILED DOWN FOR SMOOTH FINISH)
1/2" x 3/16" STEEL BAR STOCKWITH BRASS FINISH
1/2" x 3/16" STEEL BAR STOCK WEB
1/2" x 3/16" STEEL BAR STOCKFASTENED TO SIDE OF 2NDFLOOR SLAB
1/2"
1"1/
2"6"
WE
BD
IST
AN
CE
VA
RIE
S
1" x 1" x 1/8" STEEL TUBE
1/2" x 3/16" STEELBAR STOCK (TYP)
Scale:
ConsultantContactAddress
Phonee-mail
ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523
www.wilkinsonarchitects.com
New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561
National Council of Architectural Registration Board #52853
DOB Barcode
ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY 10001212.929.2491Ilya@atozengineers.com
ConsultantContactAddress
Phonee-mail
NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY 11372646-522-0589rhanna@engineer.com
MECHANICAL
STRUCTURAL
6" = 1'-0"
A-502
STAIR DETAILS II
ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021
04/03/2015
No. Description Date
6" = 1'-0"1
SUSPENDED STAIR TREAD SUPPORTDETAIL
6" = 1'-0"2
LANDING SUPPORT DETAIL AT UPPERLEVEL FLOOR
SIP PANEL FASTENED TOSTEEL TAB WELDED TOBEAM WITH THRU BOLT
CONTINUOUS STEEL TABBEYOND WELDED TO BEAM
TO SUPPORT SIP PANEL
(2) 2-1/2" 16 GA STEEL STUD HEADER
WHITE SOPREMA WATERPROOF MEMBRANE
SKYLINE 1700 TERRACE DOOR HEAD
6-1/2" R-30 SIP PANEL
3/4" MDF PANEL(NOTCHED AROUND STEEL TAB)
PL4.5X4.5X3/8 STEEL PLATEWELDED TO HSS8X3X3/8 GIRDER
AND BOLTED TO BEAM
FINISHED WOOD FASCIA
STEEL TAB WELDED TO BEAMAND BOLTED TO CHANNEL
HOMOSOTE
BASF SONOLASTIC 150 CAULK (COLOR TO MATCHEXISTING EXTERIOR FINISH PENDING BOARD APPROVAL)
CONTINUOUS 1/4" STEEL PLATEWELDED TO EAVE BEAM
HSS 8X3X3/8 GIRDER
1" AZECK PANEL
1" X 1" STEEL TUBE
3/4" CDX PLYWOOD
BENT COIL STOCK GUTTERPITCHED TO NORTHWEST END
COIL STOCK FLASHING WITHDRIP EDGE (MIN 0.05 GAUGE)
COIL STOCK FLASHING WITHDRIP EDGE (MIN 0.05 GAUGE)
HILTI KWIK-FLEX SELF-DRILLING SCREWS @16" O.C.
BACKER ROD
WOOD BLOCKING
PLASTIC HORSESHOE SHIM AS REQUIREDTO LEVEL/SQUARE NANAWALL SYSTEM
WOOD BLOCKING
EAVE BEAM WELDED TO HSS 8X3X3/8
HSS 5X5X1/2 COLUMN IN WALL BEYOND
WOOD NAILER GLUED TO GIRDER
1/2" AZEK PANEL
EXISTING PAVER SYSTEM (NO WORK)
BASF SONOLASTIC 150 EXTERIOR CAULK(COLOR TO MATCH EXISTING EXTERIORFINISH PENDING BOARD APPROVAL)
CEMENT BACKERBOARD
LATICRETE 9235 WATERPROOFINGMEMBRANE APPLIED IN (2) LAYERS WITH
REINFORCEMENT FLEECE IN BETWEEN
3/8" THICK FLOOR TILE
FLEXIBLE WATERPROOFACOUSTICAL SEALANT
QT SCU PERIMETER ISOLATION STRIP
UNMODIFIED THIN SET MORTER
BACKER ROD
WOOD BLOCKING
EXISTING CMU KNEE WALLMODIFIED IN HEIGHT
NEW PAN FLASHING WITH DRIP EDGE
HILTI KWIK-FLEX SELF-DRILLING SCREWS @16" O.C.
PLASTIC HORSESHOE SHIM AS REQUIREDTO LEVEL/SQUARE NANAWALL SYSTEM
5/8" PLYWOOD SUBFLOOR
EXISTING 2" RIGIDINSULATION
SKYLINE 1700 TERRACE DOOR SILL
EXISTING ROOF ASSEMBLY
EXISTING SLEEPER JOISTS
BASF SONOLASTIC 150 EXTERIOR CAULK(COLOR TO MATCH EXISTING EXTERIORFINISH PENDING BOARD APPROVAL)
HSS 5X5X1/2 COLUMN IN WALL BEYOND
NEW FLASHING END DAM AT WALLBEYOND (TYP. BOTH SIDES)
EXISTING WALL ASSEMBLY
C8X13.7 STEEL CHANNEL BOLTEDWITH EPOXY TO EXISTING MASONRY
3/8" STEEL BEAM
1-1/2" METAL FRAMING BOLTED WITHEXPOXY BACK TO EXISTING MASONRY
5/8" GYPSUM WALL BOARD
5/8" GYPSUM WALL BOARD
STEEL PL4.5X4.5X3/8 WELDED TOC8X13.7 CHANNEL AND BOLTED TO BEAM
ALUMINUM END CAP
POLYGAL 'THERMALGAL' PANEL
CAULK
1-1/2" METAL FRAMINGBOLTED WITH EXPOXY BACKTO EXISTING MASONRY
5/8" GYPSUM WALL BOARD
PLASTIC J-BEAD
WOOD BLOCKING
EXISTING PARAPET CAP FLASHING
EXISTING WALL ASSEMBLY
3/4" MDF PANEL
ALUMINUM CAP PROFILE
GLAZING EPDM
POLYGAL FLASHING CAP
WHITE SOPREMAWATERPROOF MEMBRANE
6-1/2" R-30 SIP PANEL
Scale:
ConsultantContactAddress
Phonee-mail
ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523
www.wilkinsonarchitects.com
New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561
National Council of Architectural Registration Board #52853
DOB Barcode
ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY 10001212.929.2491Ilya@atozengineers.com
ConsultantContactAddress
Phonee-mail
NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY 11372646-522-0589rhanna@engineer.com
MECHANICAL
STRUCTURAL
6" = 1'-0"
A-503
GREENHOUSE DETAILS
ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021
04/03/2015
6" = 1'-0"2 NANAWALL HEAD/GIRDER DETAIL
No. Description Date
6" = 1'-0"1
GREENHOUSE FLOOR DETAIL @NANAWALL RAISED SILL
6" = 1'-0"3 BEAM SEAT DETAIL
6" = 1'-0"4 UPPER POLYGAL PANEL SECTION
6" = 1'-0"5 LOWER POLYGAL SECTION
EXISTING BUILT-UPROOF MEMBRANCE
NOT TO BE DISTURBEDEXISTING ROOF & SKYLIGHTCURB ASSEMBLY
1/2" GYPSUM WALL BOARD
NEW VELUX FIXED CM DOMECURB MOUNTED SKYLIGHT 0.030" ACRYLIC INTERLAYER
WHITE LAMINATED ACRYLIC OUTER DOME
VERIFY DIMENSIONS IN FIELDEXISTING OUTBOUND CURB
A-5042
NEW SAFETY RAIL SOURCESAFETY ROOF SCREEN
FASTENED TO SKYLIGHT FRAMEWITH STEEL CLIPS 12" O.C.
(STAIRWELL SKYLIGHT ONLY)
NEW 1/2" GYPSUM WALL BOARD
NEW CURB FLASHING
CONDENSATE CONTROLGUTTER WITH WEEP HOLES
ALUMINUM SKYLIGHT FRAME
THERMAL BARRIER
EXISTING ROOF FLASHINGDO NOT DISTURB
NEW SAFETY RAIL SOURCESAFETY ROOF SCREEN
FASTENED TO SKYLIGHT FRAMEWITH STEEL CLIPS 12" O.C.
(STAIRWELL SKYLIGHT ONLY)
I. ANY ALTERATION TO ROOFING DURING REMOVAL AND CONSTRUCTION MUST BE PERFORMED BYTHE BUILDING'S ROOFING CONTRACTOR (YORK RESTORATION CORP.) TO MAINTAIN WARRANTY.
GENERAL ROOF NOTES
NEW TYPE X FIRE RATED 5/8" GYPSUM WALLBOARD. TAPE AND FINISH TO MATCH CEILING.
NEW 3-5/8" 20ga METAL RUNNER
(VE
RIF
Y IN
FIE
LD)
EX
IST
ING
RO
OF
ST
RU
CT
UR
E
EXISTING FIRE RATED 5/8"GYPSUM WALL BOARD(VERIFY IN FIELD)
EXISTING FIRE RATED 5/8"GYPSUM WALL BOARD(VERIFY IN FIELD)
NEW 3-5/8" 20ga METAL STUDS @12" O.C.
OVERLAP2" MINIMUM
(TYP ALL AROUND)
EXTEND WATERPROOFING3" PAST OPENING
(VE
RIF
Y IN
FIE
LD)
EX
IST
ING
RO
OF
ST
RU
CT
UR
E
(THICKNESS = EXISTING # OF PLYS + 1 PLY OVERLAP)NEW BUILT-UP ROOFING
FASTEN FRAMING TO EXISTING STRUCTUREWITH SELF TAPING SCREWS (TYP ALL AROUND)
NEW R-38 BATT INSULATION
(VERIFY DIMENSIONS IN FIELD)EXISTING ROOF OPENING
OVERLAP2" MINIMUM
(TYP ALL AROUND)
EXTEND WATERPROOFING3" PAST OPENING
NEW (2) LAYERS OF 3/4" FIRE TREATED CDX PLYWOOD
NEW WATERPROOFING MEMBRANE
Scale:
ConsultantContactAddress
Phonee-mail
ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523
www.wilkinsonarchitects.com
New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561
National Council of Architectural Registration Board #52853
DOB Barcode
ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY 10001212.929.2491Ilya@atozengineers.com
ConsultantContactAddress
Phonee-mail
NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY 11372646-522-0589rhanna@engineer.com
MECHANICAL
STRUCTURAL
As indicated
A-504
ROOF DETAILS
ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021
04/03/2015
No. Description Date
3" = 1'-0"1 SKYLIGHT SECTION
6" = 1'-0"2 SKYLIGHT CURB DETAIL
6" = 1'-0"3 ROOF PATCH DETAIL
3/4" HARDWOOD FINISH FLOORING
5/8" FLOATING FIRE TREATED PLYWOODSUB-FLOOR APPLIES PERPENDICULAR
TO ACOUSTICAL UNDERLAYMENT
QUIETDOWN MAX (4MM) ACOUSTICUNDERLAY WITH TAPED SEAMS
NOTE: FINISHED WOOD FASTNERESMUST NOT PENETRATE ACOUSTICALUNDERLAYMENT IN ANY WAY
1/8"
MAINTAIN 1/8" GAP BETWEENFLOOR ASSEMBLY AND WALL
HOLD 1/2" BASE TRIM 1/8" CLEARABOVE FINISHED FLOOR
ACOUSTICAL SEALANT ATFLOOR PERIMETER
EXISTING SLAB
WALL ASSEMBLY
ACOUSTICAL SEALANT
3/8" PORCELAIN TILE
LEAD SHOWER PAN
LIQUID LATICRETEWATERPROOFINGMEMBRANE # 9235
MUD SET
EXISTING FLOORASSEMBLY
NICKLE / BRONZEADJUSTABLESTRAINER
3/16" PORCELAIN TILE
5/8" BACKERBOARD
LOOSE GRAVEL OR CRUSHED TILE AT WEEP HOLES
FLASHING CLAMP WITH WEEP HOLES
THREADED, CAULKED OR NO-HUB CONNECTION
HE
IGH
T O
F L
EA
DP
AN
AB
OV
EF
INIS
HE
D S
HO
WE
RF
LOO
R
EXISTING WALLASSEMBLY
CONTINUOUS WATERPROOFINGMEMBRANE TO 6" ABOVE SHOWER HEAD
FINISHED FLOORASSEMBLY
CURB6"
EXISTING FLOOR SLAB
EXISTING WALL ASSEMBLY
CEMENT BACKERBOARD
LATICRETE 9235 WATERPROOFINGMEMBRANE APPLIED IN (2) LAYERSWITH REINFORCEMENT FLEECE INBETWEEN
3/8" THICK FLOOR TILE
HONEYWELL RADIANTFLOOR WARMING SYSTEM
MIN
IMU
M A
BO
VE
FIN
ISH
FLO
OR
EX
TE
ND
WA
TE
RP
RO
OF
ING
ME
MB
RA
NE
6"
FLEXIBLE WATERPROOFACOUSTICAL SEALANT
QT scu PERIMETER ISOLATION STRIP
3/16" THICK WALL TILE
UNMODIFIED THIN SET MORTER
LATICRETE 9235 WATERPROOFINGMEMBRANE APPLIED IN (2) LAYERSWITH REINFORCEMENT FLEECE INBETWEEN
SCHLUTER DITRA MEMBRANE
CEMENT BACKERBOARD
QUIETDOWN MAX (4MM)ACOUSTIC UNDERLAYWITH TAPED SEAMS
UNMODIFIED THIN SET MORTAR
3/8" PORCELAIN TILE
6 GAUGE LEAD SHOWER PAN
LATICRETE 9235 WATERPROOFINGMEMBRANE APPLIED IN (2) LAYERS WITHREINFORCEMENT FLEECE IN BETWEEN
MUD SET
EXISTING FLOOR SLAB
LINEAR DRAIN WITH REMOVABLESTAINLESS STEEL PERFORATED GRATE
3/16" PORCELAIN WALL TILE
5/8" BACKERBOARD
HE
IGH
T O
F L
EA
D P
AN
AB
OV
EF
INIS
HE
D S
HO
WE
R F
LOO
R
EXISTING WALLASSEMBLY
LATICRETE 9235 WATERPROOFINGMEMBRANE APPLIED IN (2) LAYERS WITHREINFORCEMENT FLEECE IN BETWEEN.TERMINATE 6" ABOVE SHOWER HEAD.
3/8" PORCELAIN TILE CURB
6"
FLASHING CLAMP WITH WEEP HOLES
THREADED, CAULKED, OR NO-HUB CONNECTION
± 3 1/2"
WA
LL O
PE
NIN
G4"
MIN
IMU
M
EXISTING GWB
5/8" BACKERBOARD
3/4" PLYWOOD
2" x 6" WOODFLOOR JOISTS@12" O.C. (TYP)
2" PVC SANITARY P-TRAP
UNMODIFIED THIN SET MORTAR
6 GAUGE LEAD SHOWER PAN
5/8" BACKERBOARD
WOOD BLOCKING
UNMODIFIED THIN SET MORTAR
3/16" PORCELAIN WALL TILE
A-5053SIM
EXISTING FLOOR SLAB
CEMENT BACKERBOARD
LATICRETE 9235 WATERPROOFINGMEMBRANE APPLIED IN (2) LAYERSWITH REINFORCEMENT FLEECE INBETWEEN
3/8" FLOOR TILE (FF-1/FF-2)WET LOCATIONDRY LOCATION..
HONEYWELL RADIANTFLOOR WARMING SYSTEM
SCHLUTER DITRA MEMBRANE
QUIETDOWN MAX (4MM)ACOUSTIC UNDERLAYWITH TAPED SEAMS
UNMODIFIED THIN SET MORTER
1/8"
MIN
.
EXISTING FLOOR SLAB
CEMENT BACKERBOARD
LATICRETE 9235 WATERPROOFINGMEMBRANE APPLIED IN (2) LAYERSWITH REINFORCEMENT FLEECE INBETWEEN
3/8" FLOOR TILE (FF-1)WET LOCATIONDRY LOCATION
..
SCHLUTER DITRA MEMBRANE
UNMODIFIED THIN SET MORTER
QUIETDOWN MAX (4MM)ACOUSTIC UNDERLAYWITH TAPED SEAMS
EXISTING FLOOR SLAB
CEMENT BACKERBOARD
LATICRETE 9235 WATERPROOFINGMEMBRANE APPLIED IN (2) LAYERSWITH REINFORCEMENT FLEECE INBETWEEN
3/8" FLOOR TILE
CORIAN SADDLE (GLACIER WHITE)
3/4" HARDWOODFLOORING
ACOUSTICAL SEALANTAT FLOOR PERIMETER
HONEYWELL RADIANTFLOOR WARMING SYSTEM
SCHLUTER DITRA MEMBRANE
QUIETDOWN MAX (4MM)ACOUSTIC UNDERLAYWITH TAPED SEAMS
UNMODIFIED THIN SET MORTER
5/8" PLYWOODSUBFLOORING
QT scu ISOLATION STRIP
1/8"
MIN
.
WET LOCATIONDRY LOCATION..
ROPE LIGHT L-RL1
3/4" PLYWOOD
3/4" SOLIDWOOD FINISH
3/4" SOLIDWOOD FINISH
2X6 WOODFRAMING @16"O.C.
EXISTING MAIN LEVELFLOOR ASSEMBLY
Scale:
ConsultantContactAddress
Phonee-mail
ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523
www.wilkinsonarchitects.com
New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561
National Council of Architectural Registration Board #52853
DOB Barcode
ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY 10001212.929.2491Ilya@atozengineers.com
ConsultantContactAddress
Phonee-mail
NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY 11372646-522-0589rhanna@engineer.com
MECHANICAL
STRUCTURAL
As indicated
A-505
FLOOR DETAILS
ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021
04/03/2015
6" = 1'-0"5 WOOD FLOOR SOUNDPROOFING DETAIL
3" = 1'-0"6 SHOWER INSTALLATION DETAIL
6" = 1'-0"3
FLOOR WATERPROOFING DETAIL @WALL
No. Description Date
6" = 1'-0"7 RAISED SHOWER INSTALLATION DETAIL
6" = 1'-0"1
FLOOR WATERPROOFING DETAIL @THRESHOLD (MAIN LEVEL)
6" = 1'-0"2 FLOOR WATERPROOFING DETAIL
6" = 1'-0"4
FLOOR WATERPROOFING DETAIL @THRESHOLD (UPPER LEVEL)
6" = 1'-0"8 STAIR PLATFORM EDGE DETAIL
ROPE LIGHTL-RL1
2"
A-5011
SIM
A-5062
A-5063
STAIRWELL KITCHEN
A-5058SIM
4
A-506
SIM
1/2" SOLID WOOD
(2) LAYERS 3/4" PLYWOOD
METAL LAMINATE
METAL LAMINATE1/2" SOLID GLASS SHELF
1/4" SOLID GLASS BACK PANEL1/4" SOLID GLASSCABINET DOORS
ROPE LIGHT L-RL2
3 1/2" 1" 3 1/2"
STAIRWELL KITCHEN
ROUTE OUT RACEWAYFOR BX WIRE
1/2" SOLID GLASS SHELF(ADJUSTABLE HEIGHT)
1/4" SOLID GLASSCABINET DOORS
1/4" SOLID GLASSBACK PANEL
5/8" GYPSUM BOARD
Z CLIPS 16" O.C.
1/2" MEDIUM DENSITYFIBERBOARD
3/4" PLYWOOD
3-5/8" METAL TRACK
3-5/8" METALSTUDS @16" O.C.
STAIRWELL KITCHEN
1/2" SOLID WOOD
(2) LAYERS 3/4" PLYWOOD
1/8" METAL LAMINATE
METAL LAMINATE
ROPE LIGHT L-RL2
1 3/4" 4" 1 3/4"
3"
EXISTING WALL ASSEMBLY
1/4" SOLID GLASS BACK PANEL
1/2" SOLID GLASS SHELF
METAL LAMINATE
(2) LAYERS 3/4" PLYWOOD
1/2" SOLID WOOD
1/2" THICK GLASS SHELF
1/2" SOLID WOOD
UPHOLSTERED HEADBOARD
5
A-506
1" 11" 2' - 2" 2' - 2" 2' - 2" 11" 1"
1"
1/4"
10"
1/4"
10"
1/4"
10"
1/4"1"3"
2' -
9"
3" 8' - 0" 3"
5
A-506
CW-1
DRAWERDRAWER
DRAWER
DRAWER
MATRESS BY OWNER
BED FRAME BY OWNER
Scale:
ConsultantContactAddress
Phonee-mail
ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523
www.wilkinsonarchitects.com
New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561
National Council of Architectural Registration Board #52853
DOB Barcode
ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY 10001212.929.2491Ilya@atozengineers.com
ConsultantContactAddress
Phonee-mail
NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY 11372646-522-0589rhanna@engineer.com
MECHANICAL
STRUCTURAL
As indicated
A-506
CASEWORK DETAILS
ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021
04/03/2015
No. Description Date
1" = 1'-0"1
KITCHEN/STAIRWELL CUSTOMCASEWORK SECTION
6" = 1'-0"2
KITCHEN/STAIRWELL CUSTOMCASEWORK SECTION - Callout 1
3" = 1'-0"3
KITCHEN/STAIRWELL CUSTOMCASEWORK SECTION - Callout 2
3" = 1'-0"4
KITCHEN/STAIRWELL CUSTOMCASEWORK SIDE SECTION DETAIL
1" = 1'-0"6 Master Bed Front Elevation
1" = 1'-0"7 Master Bed Back Elevation
3" = 1'-0"5 Master Bedroom Custom Casework Section
J-BEAD
1/4" GYPSUM WALL BOARD
PLASTER SKIM COAT
QUICKSET FASTENERS(ALTERNATING ANGLES@10" O.C.)
EXISTING FLOOR SLAB ABOVE
3-5/8" 22 GA METAL TRACK
3-5/8" 22 GA METAL STUDS
3-5/8" 22 GA METAL TRACK
1-1/2" CORSE THREADCOUNTERSUNKSCREWS @10" O.C.
FIRE TREATED WOODBLOCKING BETWEEN STUDS
RECESSED LIGHTING FIXTUREL-R1
SOLID WOOD MOLDING
1/2" MDF PAINTED WHITE
U/S OF EXISTING UPPERLEVEL FLOOR SLAB
1/4" REVEAL PAINED BLACK
1/2" PLYWOOD
EXISTING EXTERIOR WALL
SHADE
ROLER SHADE COVER PANEL
AUTOMATIC ROLER SHADE
SOLID WOOD MOLDING
5/8" GYPSUM BOARD PAINTED
ROPE LIGHT L-R2
3-5/8" 22GA METAL RUNNERS
FIRE TREATED WOODBLOCKING BETWEEN STUDS
PAINTED GYPSUM BOARD
QUICKSET FASTENERS @10"O.C. (ALTERNATING ANGLES)
3-5/8" 22GA METAL STUDS
U/S OF EXISTING EXPOSEDCONCRETE FLOOR SLAB
RECESSED LIGHTINGFIXTURE L-R2
3" 3" DISTANCE VARIES
SCHEDULED ROLLER SHADE POCKET OPENING
1/4" REVEAL PAINTED BLACK
CLEAR "U" CHANNEL
1/4" REVEAL PAINTED BLACK
DISTANCE VARIES
FIRE TREATED WOODBLOCKING BETWEEN STUDS
SOLID WOOD MOLDING
5/8" GYPSUM BOARD PAINTED
ROPE LIGHT L-RL2
1/2" MDF PAINTED WHITE
QUICKSET FASTENERS(ALTERNATING ANGLES@10" O.C.)
3-5/8" 22 GA METAL TRACK
3-5/8" 22 GA METAL STUDS
3-5/8" 22 GA METAL TRACK
FIRE TREATED WOODBLOCKING BETWEENMETAL STUDS
RECESSED LIGHTING FIXTUREL-R2U/S OF EXISTING UPPER
LEVEL FLOOR SLAB
QUICKSET FASTENERS @10" O.C.(ALTERNATING ANGLES)
3-5/8" 22 GA METAL TRACK
3-5/8" 22 GA METAL STUDS
3-5/8" 22 GA METAL TRACK
FIRE TREATED WOOD BLOCKINGBETWEEN METAL STUDS
FIRE TREATED WOODBLOCKING
RECESSED LIGHTINGFIXTURE L-R5
3/4" SOLID WOOD TRIM
3/4" SOLID WOOD TRIM
1/4" REVEAL PAINTED BLACK
Scale:
ConsultantContactAddress
Phonee-mail
ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523
www.wilkinsonarchitects.com
New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561
National Council of Architectural Registration Board #52853
DOB Barcode
ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY 10001212.929.2491Ilya@atozengineers.com
ConsultantContactAddress
Phonee-mail
NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY 11372646-522-0589rhanna@engineer.com
MECHANICAL
STRUCTURAL
6" = 1'-0"
A-507
CEILING DETAILS
ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021
04/03/2015
No. Description Date
6" = 1'-0"2 TYPICAL DROP CEILING DETAIL
6" = 1'-0"1 SHADE POCKET DETAIL
6" = 1'-0"3 TYPICAL SOFFIT DETAIL
6" = 1'-0"4
MASTER BEDROOM DROP CEILINGTYPICAL DETAIL
PLUMBING FIXTURE SCHEDULEDESIGNATION DESCRIPTION MANUFACTURER LOCATION(S)SERIES
PL-1
INTEGRATED STONE SINK WITH OVERFLOW
PL-2
PL-5 N/A
PL-4 S-AG 38
WALL HUNG TOILET WITH SEAT 1ST FLR: POWDER RM, BATHROOM 2ND FLR: MASTER BATHROOM
SHOWER HEAD
PL-6
N/APROVIDED BY OWNER 1ST FLR: KITCHEN COUNTERTOPPL-7
N/APL-8
N/A
LINEAR SHOWER DRAIN
PL-3
PROVIDED BY OWNER
PROVIDED BY OWNER
SITE BUILT
GEBERIT
TBD
INFINITY
DURAVIT
DUOFIX 111.728.00.1
STARCK #220109
TBD
CNT
WALL HUNG TOILET CARRIER WITH ACTIVATOR
UNDERMOUNT STAINLESS STEEL KITCHEN SINK
SINGLE HOLE DECK MOUNTED MASTER LAV
UNDERMOUNT STAINLESS STEEL BAR SINKPL-9
N/APROVIDED BY OWNERFAUCETPL-10
N/APROVIDED BY OWNERFAUCETPL-11
N/APROVIDED BY OWNERFAUCET
2ND FLR: MASTER BATHROOM
2ND FLR: GREENHOUSE
3
3
2
2
1
1
1
1
2
1
1
1ST FLR: POWDER RM, BATHROOM 2ND FLR: MASTER BATHROOM
1ST FLR: POWDER RM
1ST FLR: BATHROOM 2ND FLR: MASTER BATHROOM
1ST FLR: BATHROOM 2ND FLR: MASTER BATHROOM
1ST FLR: POWDER RM, BATHROOM
1ST FLR: KITCHEN
2ND FLR: MASTER BATHROOMPL-12
INTEGRATED CORIAN SINK N/ASITE BUILT1 1ST FLR: BATHROOM VANITY
N/APROVIDED BY OWNERFAUCET1 2ND FLR: GREENHOUSEPL-13
Scale:
ConsultantContactAddress
Phonee-mail
ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523
www.wilkinsonarchitects.com
New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561
National Council of Architectural Registration Board #52853
DOB Barcode
ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY 10001212.929.2491Ilya@atozengineers.com
ConsultantContactAddress
Phonee-mail
NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY 11372646-522-0589rhanna@engineer.com
MECHANICAL
STRUCTURAL
1" = 1'-0"
A-600
FIXTURE, APPLIANCE, & DOORSCHEDULES
ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021
04/03/2015
No. Description Date
LIGHTING FIXTURE SCHEDULEDesig. Cnt Description Housing / Trim Lamp Manufacturer Product ID Location(s)L-P1 1 PENDANT MOUNTED (OWNER PROVIDED) NA INCANDESCENT 1ST FLR: DININGL-P2 3 PENDANT MOUNTED (OWNER PROVIDED) NA T5 Delray Lighting 6311 2MD FLR: STAIRWELLL-R1 23 LOW VOLTAGE HALOGEN TRIMLESS HALOGEN (12OV, 277V, OR 347V) USAI 9004-10-C-FL100-120 1ST FLR: FOYER/LIVING/DINING SOFFITSL-R2 17 LOW VOLTAGE HALOGEN 4" LOW VOLTAGE REMODEL HOUSING MR16 (12V/50W) WAC LIGHTING HR-8401E 1ST FLR: LIVING/DINING & KITCHEN DROP CEILINGL-R3 4 1" LEDme MINI RECESSED ADJUSTABLE SPOT NA / LOW PROFILE TRIM WARM/NEUTRAL LED (3W) WAC LIGHTING HR-LED272R 1ST FLR: POWDER ROOM CEILINGL-R4 4 4" LEDme NEW CONSTRUCTION HOUSING / SHOWER TRIM 6 x WARM/NEUTRAL LED (3W) WAC LIGHTING HR-LED418-N 1ST FLR: BATHROOM SHOWER CEILING 2ND FLR: MASTER BATHROOM SHOWER CEILINGL-R5 12 3.5" TESLA LED NA / DOWNLIGHT TRIM LUXEON S MULTI-CHIP LED (18W) WAC LIGHTING HR-3LED-T718 2ND FLR: STAIRWELL CEILING, HALL CEILING, MASTER BEDROOM DROP CEILINGL-R6 12 1" LEDME MINI RECESSED ADJUSTABLE SPOT NA / LOW PROFILE TRIM WARM/NEUTRAL LED (3W) WAC LIGHTING HR-LED272R 1ST FLR: BEDROOM CLOSET CLG 2ND FLR: W/D CLG, ELEC CLOSET CLG, M. BEDROOM CLOSET CLGL-S1 3 SURFACE MOUNTED (OWNER PROVIDED) 2ND FLR: MASTER BEDROOM DROP CEILINGL-S2 7 SURFACE MOUNTED (OWNER PROVIDED) 2ND FLR: GREENHOUSE BAY CEILINGSL-TL1 1 14' LED TRACK LIGHTING (OWNER PROVIDED) 2ND FLR: MASTER BEDROOM CEILING (WEST)
L-WM1 2 WALL MOUNTED (OWNER PROVIDED) 1ST FLR: POWDER ROOM (BEHIND MIRROR)L-WM2 2 WALL MOUNTED (OWNER PROVIDED) 1ST FLR: BATHROOM (ABOVE MIRROR)L-WM3 1 WALL MOUNTED (OWNER PROVIDED) 1ST FLR STAIRWELL (WALL MOUNTED ABOVE STAIR PLATFORM)L-WM4 1 WALL MOUNTED (OWNER PROVIDED) 2ND FLR: MASTER BATHROOM (WALL MOUNTED W/ MIRROR SURROUND)L-WM5 1 WALL MOUNTED (OWNER PROVIDED) 2ND FLR: MASTER BEDROOM (WALL MOUNTED)L-WM6 2 WALL MOUNTED (OWNER PROVIDED) 2ND FLR: MASTER BEDROOM (WALL MOUNTED)
APPLIANCE SCHEDULEDesig. Description Manufacturer Model Location
AP-1 30" ALL GAS RANGE MIELE HR1124 1ST FLR: KITCHEN RANGE WALLAP-2 30" BUILT-IN WALL CABINET HOOD MIELE DA3480 1ST FLR: KITCHEN RANGE WALLAP-3 30" INTEGRATED O&U REFRIGERATOR/FREEZER SUB ZERO IT-30CI 1ST FLR: KITCHEN RANGE WALLAP-4 24" UNDER COUNTER MICROWAVE W/DRAWER JENN AIR JMD2124WS 1ST FLR: KITCHEN FLOATING BASE CABINETSAP-6 24" UNDER COUNTER WINE STORAGE MIELE KWT4154UG-1 1ST FLR: FOYER/LIVING CUSTOM CASEWORKAP-7 24" COMPACT WASHING MACHINE LG WM1355HW 2ND FLR: W/DAP-8 24" COMPACT ELECTRIC CONDENSING DRYER LG DLEC855W/R 2ND FLR: W/DAP-9 27" INTEGRATED WINE STORAGE SUB ZERO 427RG 2ND FLR: GREENHOUSE CUSTOM CASEWORKAP-10 24" UNDERCOUNTER DISHDRAWER DISHWASHER FISHER & PAYKEL DD24SVT7 2ND FLR: GREENHOUSE CUSTOM CASEWORK
APPLIANCE & FIXTURE NOTESI. GC TO PROVIDE AND INSTALL ALL APPLIANCES LISTED IN SCHEDULE.
II. GC TO PROVIDE ALL SUPPLY AND WASTE PIPING NECESSARY FOR THEINSTALLATION OF ALL PLUMBING FIXTURES AND APPLIANCES AS REQUIRED.
DOOR SCHEDULEMark Description Count Height Width Thickness Finish Frame Type Hardware Location(s)
1 POCKET 1 8' - 0" 2' - 8" 1 1/2" Solid Wood 1ST FLR: POWDER RM2 TOP HUNG SLIDING 1 7' - 10" 4' - 10 1/2" 2" Solid Wood 1ST FLR: BEDROOM3 POCKET 1 8' - 0" 2' - 8" 1 1/2" Solid Wood 1ST FLR: BATHROOM4 TOP HUNG SLIDING 1 7' - 10" 4' - 5 3/4" 2" Solid Wood 2ND FLR: MASTER BEDROOM5 POCKET 1 8' - 0" 2' - 8" 1 1/2" Solid Wood 2ND FLR: MASTER BATHROOM6 SINGLE FLUSH SWING RHR 1 6' - 8" 2' - 6" 2" Solid Wood 2ND FLR: GREENHOUSE7 TEMPERED GLASS OUTSWING 1 7' - 9" 2' - 7" 3/8" Extruded Aluminum Edge 1ST FLR: BATHROOM SHOWER8 TEMPERED GLASS OUTSWING 1 7' - 8" 2' - 11 1/4" 3/8" Extruded Aluminum Edge 2ND FLR: MASTER BATHROOM SHOWER9 SKYLINE 1700 TERRACE OUTSWING 1 7' - 11" 3' - 0" 1 3/4" Hollow Metal 2ND FLR: GREENHOUSE/TERRACE
C1 RECESSED SINGLE FLUSH (RH) 1 6' - 8" 2' - 6" 2" Recessed Wood 1ST FLR: BEDROOM CLOSETC2 RECESSED SINGLE FLUSH (LH) 1 6' - 8" 2' - 4" 1 1/2" Recessed Wood 2ND FLR: WASHER/DRYER CLOSETC3 RECESSED SINGLE FLUSH (RH) 1 6' - 8" 1' - 10" 1 1/2" Recessed Wood 2ND FLR: ELECTRICAL CLOSETC4 CUSTOM DOUBLE WITH GLASS LITES 3 8' - 0" 3' - 10" 2" Solid Wood 2ND FLR: MASTER BEDROOM CLOSET
FLOOR FINISH SCHEDULEDESIGNATION SIZE/MATERIAL FINISH MANUFACTURER LOCATION(S)
FF-1 3/8"x12"x24" PORCELAIN FLR TILE MATTE NASCO STONE & TILE
SERIES/COLOR
FUSSION, DARK ANTHRACITE
FF-3
3/8"x6"x24" PORCELAIN FLR TILE MATTE PROVENZAW-AGE, CORTEX NERO
FF-5 3/4" VENEERED PLYWOOD FLOOR SATIN CLEAR TBDEAST INDIAN ROSEWOOD
1ST FLR: FOYER, LIVING, DINING, KITCHEN, BEDROOM, BATHROOM
FF-6 3/4" SOLID WOOD RUBBED MONOCOAT MATTEWALNUT 1ST FLR: STAIR TREADS, KITCHEN CUSTOM CASEWORK
2ND FLR: MASTER BEDROOM, MASTER BATHROOM, GREENHOUSE
2ND FLR: MASTER BATHROOM & SHOWER
FF-2 3/8"x40"x40" PORCELAIN FLR TILE MATTE NASCO STONE & TILEFUSSION, DARK ANTHRACITE 1ST FLR: POWDER RM
FF-4
3/8"x6"x36" PORCELAIN WALL TILE MATTE DALTILEACACIA VALLY, ASH 1ST FLR: BATHROOM SHOWER
TBD
REMARKS
FIELD CUT AS NOTED IN PLAN
WALL FINISH SCHEDULEDESIGNATION SIZE/MATERIAL FINISH MANUFACTURER LOCATION(S)SERIES/COLOR
WF-1
1/2"x36"x144" CORIAN SHEET FACTORY DUPONTSOLID SURFACE, GLACIER WHITE 1ST FLR: BATHROOM 2ND FLR: MASTER BATHROOM
WF-2
3/8"x6"x36" PORCELAIN WALL TILE MATTE DALTILEACACIA VALLY, ASH 1ST FLR: BATHROOM
WC-1 DYED SILK DEGOURNAYDECORATIVE WALL COVERING KOREAN PEONY
P-3 MATTE BENJAMIN MOOREWATER BASED PAINT TBD
P-4 MATTETBD
WF-4 SATIN CLEAR TBD1/2" VENEERED PLYWOOD EAST INDIAN ROSEWOOD 1ST FLR: POWDER RM 2ND FLR: MASTER BATHROOM
1st Flr: TBD 2nd Flr: TBD
MR-1 GLASS TBDWALL MTD MIRROR SURFACE N/A
BENJAMIN MOOREWATER BASED PAINT 1st Flr: TBD 2nd Flr: TBD
WC-2 MATTE DEGOURNAYPAPER WALL COVERING ROYAL RED 1ST FLR: FOYER
1ST FLR: POWDER RM, BATHROOM 2ND FLR: MASTER BATHROOM
3/8"x40"x40" PORCELAIN WALL TILE MATTE NASCO STONE & TILEFUSSION, DARK ANTHRACITE 1ST FLR: POWDER RM
WF-3
P-1 MATTE BENJAMIN MOOREWATER BASED PAINT TBD
P-2 MATTETBD
1st Flr: TBD 2nd Flr: TBD
BENJAMIN MOOREWATER BASED PAINT 1st Flr: TBD 2nd Flr: TBD
REMARKS
PROVIDED BY OWNER1ST FLR: POWDER RM
PROVIDED BY OWNER
PROVIDED (3) SAMPLES
PROVIDED (3) SAMPLES
PROVIDED (3) SAMPLES
PROVIDED (3) SAMPLES
WB-1 MATTETBD TBDWOOD WALL BASE 2nd Flr: GREENHOUSE
WF-5 SATIN CLEAR TBD1/2" VANEERED MDF QUARTER SAWN WALNUT 1ST FLR: FOYER
CASEWORK FINISH SCHEDULEDESIGNATION SIZE/MATERIAL FINISH MANUFACTURER LOCATION(S)SERIES/COLOR
CT-1
3/4"x36"x144" CORIAN SHEET FACTORY DUPONTSOLID SURFACE, GLACIER WHITE 1ST FLR: BATHROOM VANITY C-TOP 2ND FLR: MASTER BATH VANITY C-TOPCT-2
CW-2 GLOSSY TBD
CW-1 LACQUERED TBD 1ST FLR: KITCHEN/STAIRWELL CUSTOM CASEWORK
3/4" SOLID WOOD WALNUT
1-1/8" SOLID GRANITE HONED SMC STONEABSOLUTE BLACK 1ST FLR: KITCHEN COUNTERTOP
3/4" VENEERED MDF DECORATOR WHITE
CW-3 SATIN CLEAR TBD1/4" VENEERED PLYWOOD EAST INDIAN ROSEWOOD 2ND FLR: MASTER BATHROOM VANITY
1ST FLR: KITCHEN BASE CABINETS
SS-1 BRUSHED TBD1/2" STEEL LAMINATED WOOD STAINLESS STEEL 1ST FLR: KITCHEN RANGE, ADJACENT UPPER/LOWER CASEWORK & C-TOP
GL-1 CLEAR TBD1/2" THICK GLASS N/A 1ST FLR: KITCHEN/STAIRWELL CUSTOM WALL HUNG CABINET/SHELVING
1-1/8" SOLID STONE HONED DUPONTJET MIST 1ST FLR: POWDER RM VANITY COUNTERTOPCT-3
REMARKS
EASED EDGE. RECIEVES (2) COATS OF SEALER
RECIEVES (2) COATS OF SEALER
CW-4 SATIN CLEAR TBD1/2" VENEERED MDF QUARTER SAWN WALNUT 1ST FLR: FOYER, BEDROOM SOLID WOOD EDGING
CW-5 SATIN CLEAR TBD1/2" SPRAY LAQUERED MDF TBD 1ST FLR: LIV/DINING & BDRM PTAC ENCLSR 2ND FLR: M.BDRM PTAC ENCLSR
CT-4 3/4"x36"x144" CORIAN SHEET FACTORY DUPONTSOLID SURFACE, TBD 1ST FLR: LIV/DINING & BDRM PTAC ENCLSR 2ND FLR: M.BDRM PTAC ENCLSR
CT-5 3/4" VENEERED MDF FACTORY TBDTBD 1ST FLR: BEDROOM ENTERTAINMENT CENTER COUNTERTOP & OFFICE DESKTOP
CEILING FINISH SCHEDULEDESIGNATION SIZE/MATERIAL FINISH MANUFACTURER LOCATION(S)SERIES/COLOR
CF-1
VENETIAN PLASTER FACTORY DUPONTWHITE 1ST FLR: LIVING/DINING & KITCHEN DRP CLG 2ND FLR: MASTER BED DRP CLG
CF-2
5/8" GYPSUM BOARD MATTE TBDWHITE 1ST FLR: LIVING/DINING, FOYER, & BEDROOM SOFFITS
CF-5
CF-4 SATIN CLEAR TBD1/2" VENEERED PLYWOOD EAST INDIAN ROSEWOOD 1ST FLR: FOYER/LIVING/DINING/KITCHEN SOFFIT COVE
5/8" MOISTURE RESISTANT GWB MATTE TBDWHITE 1ST FLR: BATHROOM, POWDER RM 2ND FLR: MASTER BATHROOM
CF-3
3/8"x6"x36" PORCELAIN TILE MATTE DALTILEACACIA VALLY, ASH 1ST FLR: BATHROOM SHOWER
CF-6 3/4" MEDIUM DENSITY FIBERBOARD MATTE TBDWHITE 2ND FLR: GREENHOUSE BAY CIELINGS
REMARKS
NOTCH AROUND ROOF BEAM FLANGE
MOUNT ON MOISTURE RESISTANT BACKERBOARD
Scale:
ConsultantContactAddress
Phonee-mail
ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523
www.wilkinsonarchitects.com
New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561
National Council of Architectural Registration Board #52853
DOB Barcode
ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY 10001212.929.2491Ilya@atozengineers.com
ConsultantContactAddress
Phonee-mail
NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY 11372646-522-0589rhanna@engineer.com
MECHANICAL
STRUCTURAL
1" = 1'-0"
A-601
FINISH SCHEDULES
ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021
04/03/2015
No. Description Date
FINISH NOTESI. GC TO PROVIDE SUBMITTALS FOR ALL FINISHES TO BE APPROVED BYOWNER/ARCHITECT
II. ALL STONE TO RECIEVE (2) COATS SEALER
GFI
GF
I
GFI
GF
IG
FI
GF
I
TV
TD
GFI
GF
I
GFI
TV
TD
R
UP
REF.
RANGE
HOODU.C.MICROWAVEGFI
U.C.REF.
GFI GFI
MOTORIZED SHADE(AT CEILING)
MO
TO
RIZ
ED
WIN
DO
WS
HA
DE
(C
EIL
ING
)
U.C.D/W
FCU-1
I
MOTORIZED WINDOWSHADE (CEILING) MOTORIZED WINDOW
SHADE (CEILING)
DN
MOTORIZED SHADE(AT CEILING)
W D
GFI
UP1 Riser
A B
1
I
WP
WP
I
SINGLE WALL MOUNTED RECEPTACLE
SYMBOL DESCRIPTION
ELECTRICAL RECEPTACLE LEGEND
DUPLEX WALL MOUNTED RECEPTACLE
GFI DUPLEX WALL MOUNTED RECEPTACLE
240V WALL MOUNTED RECEPTACLE
CATV WALL MOUNTED RECEPTACLE
TELE/DATA WALL MOUNTED RECEPTACLE
INTERCOM SERVICE
WATERPROOF DUPLEX WALL MOUNTED RECEPTACLEWP
Scale:
ConsultantContactAddress
Phonee-mail
ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523
www.wilkinsonarchitects.com
New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561
National Council of Architectural Registration Board #52853
DOB Barcode
ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY 10001212.929.2491Ilya@atozengineers.com
ConsultantContactAddress
Phonee-mail
NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY 11372646-522-0589rhanna@engineer.com
MECHANICAL
STRUCTURAL
1/4" = 1'-0"
E-101
POWER PLANS
ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021
04/03/2015
1/4" = 1'-0"1
Penthouse F - 36th Floor - Main Level PowerPlan
1/4" = 1'-0"2 Penthouse F - Upper Level Power Plan
ALL ELECTRICAL OUTLETS, FIXTURES, AND RELATED ITEMS BEING INSTALLED IN PUBLIC/PARTY/CHASEWALLS AND/OR CEILINGS MUST BE INSTALLED WITH SOUNDPROOF HOUSINGS AND/OR GASKETING.
GENERAL ELECTRICAL NOTES
No. Description Date
DN
UP
GAS GAS GAS
GA
SG
AS
GA
SG
AS
GA
SG
AS
UP1 Riser
C.O.
A B
1
NEW WASTE LINE
PLUMBING LEGEND
NEW VENT LINE
NEW GAS LINE
NEW CLEAN OUT
WASTE RISER
GAS GAS
C.O.
VENT RISER
RISER SHUTOFF
BRANCH SHUTOFF
Scale:
ConsultantContactAddress
Phonee-mail
ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523
www.wilkinsonarchitects.com
New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561
National Council of Architectural Registration Board #52853
DOB Barcode
ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY 10001212.929.2491Ilya@atozengineers.com
ConsultantContactAddress
Phonee-mail
NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY 11372646-522-0589rhanna@engineer.com
MECHANICAL
STRUCTURAL
1/4" = 1'-0"
P-101
PLUMBING PLANS
ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021
04/03/2015
1/4" = 1'-0"1
Penthouse F - 36th Floor - Main LevelPlumbing Plan
1/4" = 1'-0"2 Penthouse F - Upper Level Plumbing Plan
EXISTING VENT STACK(VERIFY IN FIELD)
EXISTING WASTE STACK(VERIFY IN FIELD)
EXISTING WASTE STACK(VERIFY IN FIELD)
EXISTING 6" VENT STACK(VERIFY IN FIELD)
EXISTING 4" WASTE STACK(VERIFY IN FIELD)
EXISTING 4" VENTTO ROOF
(VERIFY IN FIELD)
W/D
EXISTING RISER SHUTOFF(VERIFY IN FIELD)
NEW FIXTURE SHUTOFF(ACCESS INSIDE B.C.)
No. Description Date