EGAS Emissions Gas Analysis SystemsTurnkey analysis system: easy-to-use and suited for continuous and simultaneous measurements of THC, CH4, NmHC, NO/NOX, CO, CO2, O2, CO2 EGR and NH3

One System Measures All Engine Emissions The EGAS System benefits from leading edge metrology and a new modular design that offers reduced and simplified maintenance. Packed with features the EGAS is designed to measure all emissions from all combustion engines regardless of fuel type.

State-of-the-art Design The EGAS system has been designed with ease and functionality in mind; the front access panels ensure remote control of the system and its adjoining components. It is equipped with a separate mobile sampling trolley with built-in sample pump. Additionally, the EGAS features user-friendly networking technology for analyser control & host interface.

Rule 1065 & Diesel 2007 Compliant Offering raw or dilute analysis, the EGAS system unique measurement levels combined with high quality components and design technology ensure complete legislation compliance.

KEYBENEFITS• Positive pressure sample - no

dilution from system leaks

• Heated inlet filter on primary

sample line

• Open architecture for integration

of various analyser types

• Open architecture for integration

of various analyser types

The series 2M analysers are ultra-compact and capable of fast and accurate measurement

“ “NOx THC CO CO2 O2

GASESANALYSED

TECHNICALSPECIFICATIONGENERAL • Hang-up checker - used to check for hydrocarbon hang-

up in the sample lines

• Heated sample line; 10 meters + 3 meters

• Heated sample pump

• Back-flushing filter function

• Heated stainless steel filter

• Remote display & control

UTILITIES • Compressed air for back purge

• H2/ He (40/60%) for HFID

• N2 (100%) for zero gas

• O2 (100%)

• Air for HFID

OPERATING CONDITIONS • Ambient temperature: 5 to 35oC

• Relative humidity: max 80%

• Power supply: 250v/50/60Hz or 115V/60Hz

• Nominal power consumption: 3.2 kVA

DIMENSIONS Analyser cabinet

• 19” rack cabinet

• Dimensions: 1,360mm (H) x 600mm (W) x 800mm (D)

4’6” (H) x 2’0” (W) x 2’8” (D)

• Weight: 150kg / 330lbs

Samping trolley

• Dimensions: 1,000mm (H) x 540mm (W) x 420mm (D)

3’1” (H) x 1’9” (W) x 1’5” (D)

• Weight: 70kg / 154lbs

11 Ark Royal Way, Lairdside Technology Park, Tranmere, Wirral, CH41 9HTT: +44(0)151 666 8300 F: +44(0)151 666 8329 E: sales@a1-cbiss.com W: www.a1-cbiss.com Buy Online: shop.a1-cbiss.com

Cert No. 996ISO 9001

MODEL GRAPHITE 52M TOPAZE 32M MIR 2M

Compound THC (option CH4) NO or NOx (option NO2) CO, CO2, O2

Principle Heated FID Heated CLD NDIR & paramagnetic

Linearity <1% from 10 to 90% of F.S. <1% from 10 to 90% of F.S. <1% from 10 to 90% of F.S.

Lower Detectable Limit 0.05ppm (10ppm range) 0.1 ppm (10ppm range) <2% of F.S.

Response time (T90 sec) <1.5 s <2 s <2 s

Zero drift <2% / 7 days <1% / 7 days <1% / day

Span drift <1% / 7 days <1% / 7 days <1% / 7 days

Span gases C3H8 or CH4 NO or NOx CO, CO2, O2

ANALYSERS

RANGES GRAPHITE 52M TOPAZE 32M MIR 2M

THC 0-10/30,000 ppm

NO or NOx 0-10/10,000 ppm

CO 0-500/10,000 ppm

CO2 0-1/20%

O2 0-5/25%

ANALYSERRANGES