Eco flare presentation

Post on 14-Nov-2014

2.719 views 2 download

Tags:

description

 

Transcript of Eco flare presentation

DURABLE LIGHTWEIGHT

MAINTENANCE-FREEGLAZED COMPOSITE SOLAR PANEL

www.umasolar.com

www.umasolar.com

For more than 30 years, UMA Solar has been a preeminent force in the solar industry. As a manufacturer and distributor of the industry’s highest-performing solar products for commercial and residential applications nationwide, UMA Solar continues to meet the nation’s solar needs.

The company offers a full suite of solar products including solar pool heating systems, domestic hot water heating systems, and photovoltaic kits.

UMA Solar’s complete, turnkey solutions for all things solar, have made the company a national leader. Six strategically-located distribution centers and a national network of more than 700 partners ensure constant, continuous and convenient support of UMA Solar’s products.

For more info visit our website:www.umasolar.com

SOMETHING ABOUT USManufacturer and wholesale distributor of solar solutions

PAGE

2

www.umasolar.com

One-stop solar shop featuring the best collectors, components, and accessories at competitive prices.

PRODUCTS

Full suite of tools to support our dealers including direct-mail, press releases, literature, branding, search engine marketing, and more.

Web-based and classroom training sessions help solar newbies to seasoned industry veterans stay informed of the latest installation and designs.

MARKETING TRAINING

Multi-licensed and disciplined, we work with our dealers on their site specific design projects. We utilize the most recent CAD and engineering software.

ENGINEERING

Contests with exotic vacations and prizes, along with promotional accounts available to all dealers, gives you one more reason to continue growing your business.

INCENTIVES

UMA Solar helps you get started, and then keeps you growing with state-of-the-art proprietary tools and resources only available to dealers.

SUPPORT

OUR SERVICESHow we help you grow in the solar business

PAGE

3

www.umasolar.com

VictorEyalChief Executive Officer

OUR TEAM MEMBERSExecutive management team

PAGE

4

RobertZrallackChief Operations Officer

OfirEyalChief Financial Officer

TodEllingtonDirector of Marketing

PaulHurleyProduction Manager

www.umasolar.com

WHY ECO FLARE IS REVOLUTIONARYOverview

PAGE

5

GlazingMultiwall Polycarbonate glazing with additional UV blocking layer for over 20-year clear life. Light weight with extreme impact resistance - 200 times more than glass.

MaterialProprietary polymer formulation; tested in certification labs and proven to be stabilized against the effects of sustained UV radiation, extreme weather conditions, corrosion, scale, salts and seawater. High-pressure and temperature resistance.

AbsorberOver 100 individual polymer riser tubes connected to a proprietary freeze-resistant square manifold header via over-molding injection.

InsulationPolyurethane foam and Polyester coated Aluminum foil

Casing & frameReinforced polymer and Aluminum components are very light weight for easy installation and minimal roof load

Back PlateUV stabilized polypropylene back plate

Freeze EngineeringOnly solar panel that can withstand internal freezing. Can be installed as an open loop system in most applications without any freeze valve or drain-back protection.

www.umasolar.com

Patent pending square manifold header with extreme pressure and temperature resistance can sustain freezing temperatures down to 0oF (-17oC) as well as 175oF (80oC) water temperature under pressure.

PAGE

MANIFOLD HEADERFreeze Resistant

6

www.umasolar.com

HIGH-TEMP STAGNATION PROTECTION

PAGE

7

Tested:+ 7 hours+ 150 PSI+ 176°F

www.umasolar.com

Patented venting mechanism at the collector’s 4 corners open and close the casing structure at preset temperatures to eliminate the risk of overheating damage to the poly absorber.

PAGE

VENTING MECHANISM8

www.umasolar.com

CFD ANALYSIS: VENTING EFFECT

PAGE

9

www.umasolar.com

VENTING EFFECT TESTSPAGE

10

www.umasolar.com

VENTING EFFECT TESTSPAGE

11

230FVents Open Automaticall

y

290FClosed Vents

Typical graph shown: collector inclination 30 degrees

www.umasolar.com

INTERNAL FREEZE TESTSPAGE

12

Internal Freezing Stress Analysis Solid State Freezing Tests

www.umasolar.com

AEROSPACE FREEZE CHAMBER TESTS

PAGE

13

www.umasolar.com

FREEZE CYCLESPAGE

14

Cycles of freeze test (+110°F to –4°F at 90 PSI)

www.umasolar.com

DIMENSIONS AND SPECIFCATIONS

PAGE

Model SLRH-25

Gross area [ft2] 24

Net area [ft2] 21

Length [inch] 85

Width [inch] 40

Height [inch] 3.15

Weight (empty) [lb.] 37

Fluid capacity [gal.] 1.6

Operating pressure [PSI] 75

Test pressure [PSI] 150

Freezing resistance [°F] 0

15

www.umasolar.com

COLLECTOR OUTPUTPAGE

SLRH-25 Units Water temperature

22,400 BTU/dayCool 95oF

5,700 Kcal/day

19,850 BTU/dayMedium 122oF

5,050 Kcal/day

16

www.umasolar.com

HEADER DESIGNPAGE

17

www.umasolar.com

HEADER DESIGNPAGE

18

www.umasolar.com

FINAL HEADER DESIGN PAGE

Patent PendingBurst Pressure: 750 PSI (50 bar)

Freeze Resistance: 0°FOperating Pressure: 75 PSI @

170°F

19

www.umasolar.com

OUTDOOR EXPERIMENT STATION

PAGE

20

www.umasolar.com

WIND & SNOW LOAD EFFECT TESTS

PAGE

Wind Load- Suction (15 PSI) Snow Load (Gravel) of 550 lb.

21

www.umasolar.com

WATER INGRESS TESTSPAGE

4 hrs @ 2.5 GPM rain showers: Water ingress is lower than 2.2 ounces

22

www.umasolar.com

FLOW DISTRIBUTION TESTSPAGE

23

www.umasolar.com

FLOW DISTRIBUTION TESTSPAGE

24

www.umasolar.com

EFFICIENCY COMPARISIONPAGE

CopperCollector

25

www.umasolar.com

SUNNY WINTER DAYPAGE

Temp development in the tanks

60

70

80

90

100

110

120

130

140

08:2

308

:45

09:0

809

:30

09:5

310

:15

10:3

811

:00

11:2

311

:45

12:0

812

:30

12:5

313

:15

13:3

814

:00

14:2

314

:45

15:0

815

:30

Time [h]

Te

mp

[ F ]

Sq.m 3 mod - horizontal tank

Hel.m 3 mod - horizontal tank

Sq.m 4 mod - vertical tank

Metal - vertical tank

26

www.umasolar.com

PRESSURE DROPPAGE

y = 0.0003x2 + 0.041x

0

2

4

6

8

10

12

14

16

18

0 50 100 150 200

Mass flowrate [lit/h]

Pres

sure

dro

p [m

bar]

Recommended working point for forced flow systems

27

www.umasolar.com

SAMPLE INSTALLATIONSPAGE

MexicoSouth AfricaIsrael

28

www.umasolar.com

SAMPLE INSTALLATIONSPAGE

52o C125o F

New Zealand on a partly cloudy day

29

www.umasolar.com

SAMPLE INSTALLATIONSPAGE

University installation: 81 collectors

30

www.umasolar.com

INSTALLATION DIAGRAMPAGE

Hot Household Water

Cold Household Water

Thermosiphon System with Horizontal Storage Tank

Controller

Pump

Hot Household Water

Cold HouseholdWater

Forced Flow System

31

www.umasolar.com

UMA Solar manufactures and distributes the industry’s highest-performing solar products for commercial and residential applications nationwide.

With more than 30 years of experience in the solar industry, UMA Solar offers a turnkey solution for all things solar including commercial preheating, pool heating, domestic hot water heating and photovoltaic kits.

Corporate Office: 950 Sunshine Lane

Altamonte Springs, FL 32714

Phone: 800.79.SOLAR (76527)E-mail: sales@umasolar.comWebsite: www.umasolar.com

PAGE

CONTACT USWe are here to help you grow

32

Social networks:facebook.com/umasolar

twitter.com/umasolar

linkedin.com/umasolar

THANKS FORCOMING

See you soon

www.umasolar.com