DynaPulseNon-invasive Blood pressure and Hemodynamic Monitoring

Example Applications: Cardiac Rhythm & Hypertension

Managements

www.dynapulse.com

Pulse Metric USA

Cardiac Rhythm Management:Pulse waveform of each measurement

identifies cardiac rhythm……

Normal

Every Time A Blood Pressure Measurement is Taken…

Arrhythmia

Pulse Waveform is Displayed for Each Measurement ……

The adoption of DynaPulse technology by physicianswill result in more patients with arrhythmias

being identified and referred to the electro-physiologist and significantly improve the

Cardiac Rhythm Management.

Managing 140/90 Borderline Hypertension with DynaPulse

Case-1 had blood pressure of 140/91 with higher cardiac output (CO=8.42 vs. 4.25) and lower systemic vascular resistance (SVR=1016 vs. 2053), suggested case-1 use beta-blocker for treatment.

 

Case-2: Had blood pressure of 142/91, but with lower brachial artery distensibility (BAD=4.49 vs. 6.46) and compliance (BAC=0.047 vs. 0.123), which indicated Case-2 had stiffer peripheral arterials and vessel-dilating drug ACEI was suggested.

Hypertension Management:Hemodynamic values provide beyond Systolic/Diastolic for managing hypertension……

Case 1 (140/91 mmHg) Case 2 (142/91 mmHg)

Hypertension Management:Hemodynamic values provide beyond Systolic/Diastolic formanaging hypertension……

Case 1 (140/91) Case 2 (142/91)

Hemodynamics in HypertensionHemodynamic values provide beyond Systolic/Diastolic for managing hypertension……

Hypertension Management:Hemodynamic values provide beyond Systolic/Diastolic formanaging hypertension……

Case 1 (140/91) ”Beta-Blocker…for high CO…”

Case 2 (142/91) ”ACEI…for high SVR and low SVC, BAC & BAD…”

Advanced Clinical Applications:24 Hour Ambulatory Blood Pressure

& Hemodynamic Monitoring…24-hr ABP monitoring(ABPM) can Identify Dipper, non-Dipper & over-Dipper…

It’s more predictive thanoffice BP measurements.

24-hr Hemodynamic profiling provides unique and advancedclinical applications…

24 Hour Ambulatory Blood Pressure Monitoring (ABPM)

ABPM is ideal for

I. Clinical evaluations of:

• White Coat HPTN • Essential HPTN • Heart disease/HPTN • Renal disease/HPTN

II. Clinical studies on:

• HPTN drugs & effectiveness• Stroke/CAD/CHF & HPTN• Diabetes & HPTN• Obesity & HPTN• Genetics & HPTN• Pregnancy & HPTN• Occupation/Stress & HPTN

ABPM is reimbursable nationwide for Hypertension (HPTN) evaluations since 2003 via ICD-9 codes and CPT codes.

The AdvantageThe Advantage

Brachial Artery

Compliance

Cardiac OutputSystemic Vascular Resistance

LV dP/dt

DynaPulse is the only technology that

acquires blood pressures, central

and peripheral hemodynamic

values

Simultaneously.

                     

 

24-HourABPM

The Easy-To-UseThe Easy-To-UseHemodynamic ProfileHemodynamic Profile

DynaPulse is the only technology that acquires blood pressures, central and

peripheral hemodynamic values Simultaneously.

                     

 

The Clinically Proven TechnologyThe Clinically Proven Technology

DynaPulse is the only technology that acquires

blood pressures, central and peripheral hemodynamic

values Simultaneously.

                     

 

Pulse Dynamics e-book describes the physics of

DynaPulse technology, and summarizes its clinical validation & application studies since 1995.

Whose Using It:Whose Using It:

Parke Davis

Whose Using It:Whose Using It: