DOM Two Dimensional Scanning using testDAQ Hiroko Miyamoto T. Noda Faculty of Science Department of...

Post on 29-Jan-2016

213 views 0 download

Tags:

Transcript of DOM Two Dimensional Scanning using testDAQ Hiroko Miyamoto T. Noda Faculty of Science Department of...

DOM Two Dimensional ScanDOM Two Dimensional Scanningning

using testDAQusing testDAQ

Hiroko MiyamotoHiroko MiyamotoT. NodaT. Noda

Faculty of Science

Department of Physics

Chiba University

Reminder: We did 2D scan for bare PMTs

• CE uniformity : Some tube to tube differences

• Gain uniformity: Almost universal behavior

Implementedby ROMEO

New: 2D scan for DOMs

CE uniformity / Gain uniformity:

• Present: Rely on Geant4 MC + the bare PMT calibration data to predict DOM acceptance. The complex structure of DOM has not been implemented in the MC.

• Easier and more reliable to MEASURE it directly!

2D Scanning System for DOM

Harness

wire

DOM 2D Scanning System

SetupLight Source:• NICHA 375nm UV-LED• 100-200 PEs / shot, fired 1.6kHz by pulser

2D scanning system• Spot size: ~1cm with the collimator• Scan 4 in ~5cm intervals from point to point• Do “testDAQ” ( ‘ready’ and ’go’) at each point.

DOM• Virgo, Rev4• Unsealed DOM, room temperature, ~1atm• TestDAQ : taking data with ~4PE threshold, 1e+07Gain

Analysis Method(preliminary)

(using the java program written by Chris W.)

• Calculate the photoelectron number with domcal Calibration (J.Braun?).

• Use the average of ~3,000 samples for each point of the DOM surface.

Results(preliminary…)

Harness Harness

top topcenter

Harness Harness

top topcenter

Results(preliminary…)

HarnessHarness

top topcenter

Results(preliminary…)

top topcenter

~25cm

HarnessHarness

Forward region

Backward region

Backward region

Results(preliminary…)

HarnessHarness

top topcenter

Results(preliminary…)

top topcenter HarnessHarness

Results(preliminary…)

top topcenter HarnessHarness

~25cm

Results(preliminary…)

Summary(Preliminary…)

• Took a first data of DOM photon CE map (along 1 axis).

• “effective” diameter of photon detection area is approximately 25 cm, which is consistent with the PMT cathode area we had measured previously.

• Photons hitting from backside of DOM do not produce measurable signals. To map out this region, we must improve our triggering : currently internal trigger with 4 PE threshold.

Issues to be resolved

• It would be better to trigger DOM EXTERNALY for taking non-biased data – Internal trigger with 4PE threshold may cause bias in scanning backside of DOM sphere.

• Domcal charge estimation may contain some errors in the estimation of the total charge (photoelectron #) of each channels.

• Need to figure out a way to turn off and on data taking without recycling HV power.

Outlook

• 4 measurement and map the CE on the whole DOM surface to be implemented by the detector MC simulation.

• Produce the standard-EYE DOM scanned by this method.

Near future plan

• Absolute calibration of DOM by scattered light from N2 laser : We did for bare PMTs

It would be nicer if external trigger available