Post on 09-Oct-2020
FIL
E N
O. 177-5
82 R
EV. 2
PLAN VIEW
FRONT ELEVATIONSIDE ELEVATION
AIR VENTS
")21(
13
")87
(30
784")21(
13
810
")87
(31
1013
")16
9(2
65
")8
7(3
9 1078
")16
7(4
2
1125
")16
5(4
4
441
")169
(14
369
")83
(17
810
")87
(31
1553
")8
3 (
10
")8
1(6
1
1563 ")2
1(6
1
520
")1615(17
455
")21(1
38 ")21(20
1013
")169(4
116 ")87(39
260
")1611(16
424
")1615(12
329
")41(10
1013")16
9(4
116
")87(39
1129
")167(44
")8
1(3
79
")16
7(2
62
POWER CORD
ON PAGE 2 OF 5
SCANNER (SEE "CAUTION" LABEL)
OPTIONAL CONSUMER BAR CODE
SAFE
SAFE
SEE PAGE 5 OF 5
AND CONSUMER ACCESS DIMENSIONS
FOR VARIOUS FASCIA CONFIGURATIONS
NOTE:
815
")161
(32
SAFE AND HINGES
TP-821475-001A.
PLEASE SEE PLANNING AND SITE PREPARATION GUIDE
BRANCH FOR ADDITIONAL DETAILS AND INFORMATION.
CONSULT WITH DIEBOLD NIXDORF INSTALLATION/SERVICE
") CEN-L SAFE21WITH 13mm (
FRONT LOAD
CS 828 LOBBY CASH RECYCLER
SU
BJE
CT T
O C
HA
NG
E W
ITH
OU
T N
OTIC
E"
"ALL DIM
EN
SIO
NS A
ND D
ESIG
N C
RIT
ERIA
PR
OJE
CTIO
N
THIR
D A
NG
LE
(DIM
EN
SIO
NS I
N I
NC
HE
S)
DIM
EN
SIO
NS I
N M
ILLIM
ET
RE
S
PA
GE 1 O
F 5
CALL 1-800-999-3600L996
TRANSACTION IN PROGRESS
RAPID PROCESSING991 WATTS
BACK ELEVATION SIDE ELEVATION
1
1
4
2
3
AIR VENTS
EXPOSED CONDUIT FOR EXISTING CONSTRUCTION.
NEW CONSTRUCTION OR BOXES CAN BE SURFACE MOUNTED WITH
BOXES CAN BE FLUSH MOUNTED WITH CONCEALED CONDUIT FOR
TO CABLE CONNECTION PLATE.
") RIGID CONDUIT FROM JUNCTION BOX 43CONDUIT OR 19mm (
") LIQUID TIGHT FLEX METAL 43OWNER'S E.C. TO RUN 19mm (
NOTE:
200-240 VAC (±10%) SERVICE, DISCONNECT AT 10 AMPERES
100-127 VAC (+6%, -10%) SERVICE, DISCONNECT AT 20 AMPERES
SIGNAL CABLE RUN CONSTRAINTS
ELECTRICAL EQUIPMENT CABLE RUN.
OF THE SIGNAL CABLE RUN WITH RESPECT TO OTHER POWER AND
THE FOLLOWING CHART ITEMIZES THE PHYSICAL SPACING REQUIREMENTS
AND WILL NOT WITHSTAND AS MUCH STRAIN IN INSTALLATION.
POWER AND LIGHTING CABLE, SIGNAL CABLES HAVE CONDUCTORS AND LIGHT INSULATION
RELATIVE CARE IS REQUIRED WHEN INSTALLING SIGNAL CABLES IN CONDUITS, UNLIKE
TYPE OF ELECTRICAL RUN
LIGHTING FIXTURES
FLUORESCENT, NEON OR INCANDESCENT
ELECTRICAL EQUIPMENT
UNSHIELDED POWER LINE OR
CONDUIT
WITH SIGNAL CABLES IN GROUNDED
POWER LINES IN GROUNDED CONDUIT
BELOW 2 KVA 2-5 KVA ABOVE 5 KVA
127mm (5") 127mm (5") 127mm (5")
127mm (5") 305mm (1'-0") 610mm (2'-0")
")2164mm (2 152mm (6") 305mm (1'-0")
")16330mm (1 76mm (3") 152mm (6")
SIGNAL CABLE INSTALLATION CONSTRAINTS:
POWER REQUIREMENTS:
AIR VENTS
810
")87(31
168
")163(12
310
")85(6
")8
1(3
79
")8
1(41
04
CONDUIT AND JUNCTION BOX REQUIREMENTS
1
2
3
4
200-240 VAC (±10%) AT 60 (±1%) Hz, SINGLE-PHASE
200-240 VAC (±10%) AT 50 (±1%) Hz, SINGLE-PHASE
100-127 VAC (+6%, -10%) AT 60 (±1%) Hz, SINGLE-PHASE
100-127 VAC (+6%, -10%) AT 50 (±1%) Hz, SINGLE-PHASE
MACHINE STATUS
IDLE (NO TRANSACTION)
OR BULK NOTE) IN PROGRESS
TRANSACTION (DISPENSE
315 WATTS
585 WATTS
CONFIGURATION:
80mm THERMAL RECEIPT PRINTER, IDM, 4 HIGH AFD, AND ECRM
PROCESSOR, SVD LCD CONSUMER DISPLAY, MOTORIZED CARD READER, JOURNAL PRINTER,
USAGE
POWER
POWER USAGE AND HEAT OUTPUT:
OUTPUT
HEAT
1075 BTU
1996 BTU
3381 BTU
GROUNDED CONDUIT
SIGNAL CABLES ENCLOSED IN
ELECTRICAL EQUIPMENT WITH
UNSHIELDED POWER LINES OR
OPERATING ENVIRONMENT:SAFE LOCATION
20 TO 55% AT 38º C (100º F)
20 TO 80% AT 32º C (90º F),
RELATIVE HUMIDITY (NON-CONDENSING)
10º C TO 38º C (50º F TO 100º F)
946kg (2,086 LBS.)
154
")43(20
526
")161(6
")43(5
147
")21(3
89
")16
9(1
40
")16
11
(4
119
")4
1(1
32
CAUTION LABEL
SEPARATION FROM OTHER CABLES
SAFE
1129
")167
(44
3
BOX (ALL BY OWNER'S E.C.).
") DEEP JUNCTI0N 81JUNCTION BOX TO 102mm (4") SQ. X 54mm (2
25mm (1") METAL CONDUIT FROM ALARM CONTROL CABINET
(ALL BY OWNER'S E.C.) (SEE POWER REQUIREMENTS).
BOTTOM CONNECTION MUST BE COMPENSATED ACCORDINGLY
RECEPTACLE WITHIN 2210mm (87") OF SIDE CONNECTING PLATE.
") DEEP JUNCTION BOX WITH 81TO 102mm (4") SQ. X 54mm (2
") METAL CONDUIT AND UNSWITCHED ELECTRICAL SUPPLY 4319mm (
SPECIFIC POWER PLUG. THE POWER SUPPLIED MUST BE AS SPECIFIED BELOW.
GROUND IS NOT ACCEPTABLE). THE RECYCLER WILL PROVIDE A POWER CORD WITH A COUNTRY
WIRING TO THE RECEPTACLE MUST INCLUDE A THIRD-WIRE EARTH GROUND (CONDUIT
THE RECYCLER REQUIRES A SINGLE-PHASE, THREE-WIRE UNSWITCHED POWER RECEPTACLE.
MUST TURN OFF THE LINE VOLTAGE AT THE FOLLOWING AMPERAGE.
AT THE ELECTRICAL SERVICE PANEL. THE QUICK-DISCONNECT DEVICE (OR CIRCUIT BREAKER)
SAFETY QUICK-DISCONNECT DEVICE TO BREAK LINE VOLTAGE (SUCH AS A CIRCUIT BREAKER
POWER TO THE RECYCLER IS TO BE A DEDICATED SERVICE AND MUST BE PROTECTED BY A
SHORT-TERM AC POWER FLUCTUATIONS AS OUTLINED IN EN61000-4-11.
POWER CONDITIONING TO PREVENT THE RECYCLER FROM MALFUNCTIONING DUE TO
THE MODULE BULK POWER SUPPLY AND PROCESSOR POWER SUPPLY WILL PROVIDE
LENGTH 2184mm (86") FROM SIDE OF RECYCLER.
SPECIFIC PLUG-IN CONNECTOR SUPPLIED WITH RECYCLER. POWER CORD
OWNER'S E.C. TO SUPPLY COMPATIBLE RECEPTACLE FOR COUNTRY
PROVIDED WITH RECYCLER). LOCATE IN AN EASILY ACCESSIBLE AREA.
CONNECTING PLATE. (LENGTH OF ELECTRICAL POWER CABLE
JUNCTION BOXES MUST BE LOCATED WITHIN 2210mm (87") OF
WEIGHT OF RECYCLER:
FIL
E N
O. 177-5
82 R
EV. 2
SU
BJE
CT T
O C
HA
NG
E W
ITH
OU
T N
OTIC
E"
"ALL DIM
EN
SIO
NS A
ND D
ESIG
N C
RIT
ERIA
PR
OJE
CTIO
N
THIR
D A
NG
LE
(DIM
EN
SIO
NS I
N I
NC
HE
S)
DIM
EN
SIO
NS I
N M
ILLIM
ET
RE
S
PA
GE 2 O
F 5
NOTE:REQUIRED MINIMUM SERVICE AREA
REQUIRED MINIMUM SERVICE AREA
(14")
356
(42")
1066
(56")
1422
")8
7(3
9
1013
(2")
51
2486 ")8
7(9
7
731
")16
9(7
192
")16
13
(28
1150
")8
5(1
9499
")16
5(9
237
")8
5(2
3600
")4
1(4
5
(2")
51 514
(6")
152
")4
1(2
0
306
")83
(48
1229
(14")
356
")161
(12
(14")
356
")87
(31
810
(14")
356
1522
")169
(14
370
")1615
(59
1892
")21
(74
PLAN VIEW - REQUIRED MINIMUM SERVICE AREA
SA
FE
SAFE
BRANCH FOR SPECIAL BUILDING CONDITIONS.
SERVICE TIME. CONSULT WITH DIEBOLD NIXDORF INSTALLATION/SERVICE
THE RECOMMENDED AREA MAY RESULT IN AN INCREASE IN INSTALLATION AND
IMPROVE INSTALLATION AND SERVICE ACCESS. USE OF ANY AREA LESS THAN
SERVICE. DIMENSIONS SHOWN MAY BE INCREASED WHEREVER POSSIBLE TO
SHOWN IS THE REQUIRED MINIMUM SERVICE AREA FOR INSTALLATION AND
MUST ENTER RECYCLER IN THIS AREA
ALL ELECTRICAL AND DATA CABLES
FIL
E N
O. 177-5
82 R
EV. 2
SU
BJE
CT T
O C
HA
NG
E W
ITH
OU
T N
OTIC
E"
"ALL DIM
EN
SIO
NS A
ND D
ESIG
N C
RIT
ERIA
PR
OJE
CTIO
N
THIR
D A
NG
LE
(DIM
EN
SIO
NS I
N I
NC
HE
S)
DIM
EN
SIO
NS I
N M
ILLIM
ET
RE
S
PA
GE 3 O
F 5
FIL
E N
O. 177-5
82 R
EV. 2
ALARM CABLES (SIDE ENTRY)
") DIA. HOLE FOR8129mm (1
(SIDE ENTRY)
AND DATA CABLES
OPENING FOR POWER CORD
POWER CABLE PLATE
NOTES:FOR ADDED SECURITY:
455
")2
1(2
0520
")2
1(1
38
")16
15
(17
")43
(1
45
")169
(28
725 ")169
(1
40
810
")87
(31
110
")16
7(6
163
")8
1(2
9740
")16
5(4
1013 ")8
7(3
9
1 1
11
YOUR INSTALLATION.
ANCHOR BOLTS. USE THE FOLLOWING GUIDELINES TO DETERMINE THE APPROPRIATE METHOD FOR
IT IS RECOMMENDED THAT THE RECYCLER SAFE BE SECURED TO THE FLOOR WITH
ANCHORING THE RECYCLER TO CONCRETE FLOORS:
PLAN/SECTION - SAFE FLOOR1- (4) 25.4mm (1") DIA. FLOOR MOUNTING HOLES
(8")
203
MIN.
(4")
102
MIN.
203mm (8")
MINIMUM HOLE DEPTH
102mm (4")
MINIMUM CONCRETE DEPTH
VIEW "A" VIEW "B"
CABLE ENTRY NOTE:
CABLE ENTRY (SEE NOTE)
ANCHORED. REFER TO VIEW "A" AND "B" FOR ADDITIONAL DETAILS.
EQUIPPED WITH LEGS, THE LEVELING LEGS MUST BE REMOVED BEFORE THE RECYCLER IS
ANCHOR BOLTS MUST BE USED IN ALL AVAILABLE ANCHOR HOLES. IF THE RECYCLER IS
(4") THICK FOR ANCHORING TO BE EFFECTIVE. THERE IS NO LIMIT FOR MAXIMUM THICKNESS.
IS 203mm (8") LONG. CONCRETE FLOORS OR CONCRETE BASES MUST BE A MINIMUM OF 102mm
") ANCHOR BOLT THAT43WHENEVER POSSIBLE. DIEBOLD NIXDORF RECOMMENDS USING A M20 OR 19mm (
IT IS RECOMMENDED THAT THE RECYCLER BE ANCHORED TO CONCRETE FLOORS
SAFE
SA
FE
OF THE SAFE AS VIEWED FROM THE FRONT OF THE RECYCLER.
OPENING. THE CABLE ENTRY OPENING IS ON THE RIGHT SIDE
THE INTERIOR SIDE WALL OF THE SAFE AT THE CABLE ENTRY
SAFE AND THROUGH A RESTRICTOR BRACKET ATTACHED ON
CABLE PLATE ATTACHED TO THE EXTERIOR SIDE WALL OF THE
CABLES ENTERING THE RECYCLER PASS THROUGH THE POWER
THROUGH A CABLE ENTRY OPENING ON THE SIDE OF THE SAFE.
ELECTRICAL AND DATA CABLING ENTERS THE RECYCLER
DIEBOLD NIXDORF PART NUMBER 29-016376-000A, HILTI PART NUMBER 282520).
")-10 X 203mm (8") LONG WEDGE ANCHORS (SUPPLIED BY OWNER'S INSTALLER) 4319mm (
WHEN POSSIBLE AND TO BE SECURED TO THE CONCRETE FLOOR WITH (4)
IN CONCRETE FLOOR (RECOMMENDED DRILLING COMPLETELY THROUGH FLOOR
") DIA. X 203mm (8" MIN.) DEEP HOLES43OWNER'S INSTALLER TO DRILL (4) 19mm (
SU
BJE
CT T
O C
HA
NG
E W
ITH
OU
T N
OTIC
E"
"ALL DIM
EN
SIO
NS A
ND D
ESIG
N C
RIT
ERIA
PR
OJE
CTIO
N
THIR
D A
NG
LE
(DIM
EN
SIO
NS I
N I
NC
HE
S)
DIM
EN
SIO
NS I
N M
ILLIM
ET
RE
S
PA
GE 4 O
F 5
CONSUMER ACCESS DIMENSIONS
HEIGHT - FROM BOTTOM OF SAFE
TOP
FUNCTION
KEY
HEIGHT DEPTH HEIGHT DEPTH HEIGHT DEPTH DEPTHHEIGHT DEPTHHEIGHT DEPTHHEIGHT DEPTHHEIGHT
BAR CODE
SCANNER
DEPTHHEIGHT DEPTHHEIGHT
LCD ECRM
ADVANCED
FUNCTION
DISPENSER
IDMbd
LOWER
CARD
READER
RECEIPT
PRINTER
TOP FUNCTION KEY
LCD
ECRM
ADVANCED FUNCTION DISPENSER
BAR CODE SCANNER
COIN DOOR
CARD READER
IDMbd LOWER
KEYPAD (MIDDLE EPP KEY)
RECEIPT PRINTER
TOP OF TOUCH SCREEN
HEIGHT DEPTH HEIGHT DEPTH
TOP OF
TOUCH
SCREEN
KEYPAD
(MIDDLE EPP
KEY)
COIN
DOOR
")41(2
57
TOP OF TOUCH SCREEN
TOP FUNCTION KEY
LCD
PASSBOOK PRINTER
ECRM
KEYPAD (MIDDLE EPP KEY)
BAR CODE SCANNER
CARD READER
IDMbd UPPER
ADVANCED FUNCTION DISPENSER
RECEIPT PRINTER
HEIGHT - FROM BOTTOM OF SAFE
TOP
FUNCTION
KEY
HEIGHT DEPTH HEIGHT DEPTH HEIGHT DEPTH DEPTHHEIGHT DEPTHHEIGHT DEPTHHEIGHT DEPTHHEIGHT
BAR CODE
SCANNER
DEPTHHEIGHT DEPTHHEIGHT
LCD ECRM
ADVANCED
FUNCTION
DISPENSER
CARD
READER
PASSBOOK
PRINTER
HEIGHT DEPTH HEIGHT DEPTH
TOP OF
TOUCH
SCREEN
KEYPAD
(MIDDLE EPP
KEY)
RECEIPT
PRINTER
IDMbd
UPPER
DEPTHHEIGHT
IDM V
LOWER
IDM V
UPPER
HEIGHT DEPTH
IDM V UPPER
IDM V LOWER
")85(45
1159
")85(8
220
")21(41
1054
")161(7
180
")41(38
973
")161(7
180
")169(33
852
")43(4
120
")169(28
725
")43(
20
")87(34
886
")43(4
120
(38")
966
")21(40
1028
")43(4
120
")43(4
120
")85(42
1083
")85(45
1159
")85(8
220
")21(41
1054
")161(7
180
")41(38
973
")161(7
180
")169(33
852
")43(4
120
")169(28
725
")43(
20
")43(4
120
")43(4
120
")87(35
911
")41(35
895
")21(40
1028
")43(4
120
")81(48
1222
")43(4
120
")81(48
1222
")43(4
120
")87(34
886
")43(4
120
")163(33
843
")163(33
843
")41(2
57
")161(7
180
")81(10
257
")1615(49
1268
")1615(49
1268
")81(10
257
DEPTH - FROM FRONT EDGE OF LOWER DOOR TRIM BEZEL
DEPTH - FROM FRONT EDGE OF LOWER DOOR TRIM BEZEL
HEIGHT - FROM BOTTOM OF SAFE
DEPTH - FROM FRONT EDGE OF LOWER DOOR TRIM BEZEL
FIL
E N
O. 177-5
82 R
EV. 2
SU
BJE
CT T
O C
HA
NG
E W
ITH
OU
T N
OTIC
E"
"ALL DIM
EN
SIO
NS A
ND D
ESIG
N C
RIT
ERIA
PR
OJE
CTIO
N
THIR
D A
NG
LE
(DIM
EN
SIO
NS I
N I
NC
HE
S)
DIM
EN
SIO
NS I
N M
ILLIM
ET
RE
S
PA
GE 5 O
F 5