10) The Contractor and Owner shall follow and practice all drainage measures and irrigation practices as described in the soils report.
AutoCAD SHX Text
There is a risk of vertical slab movement. This foundation design assumes that the Contractor and Owner have reviewed and accepted the soils report, and accepts the risk of possible vertical movement in the floor slabs.
AutoCAD SHX Text
9)
AutoCAD SHX Text
shall be performed per the Soils Report.
AutoCAD SHX Text
soil engineer. No concrete shall be poured on frozen ground, water, ice,
AutoCAD SHX Text
All concrete foundations shall rest on bearing strata approved by the
AutoCAD SHX Text
or snow. All soil compaction for foundations and slabs and backfilling
AutoCAD SHX Text
2)
AutoCAD SHX Text
grade beam concurrently. No moderately or highly expansive soil shall
AutoCAD SHX Text
3)
AutoCAD SHX Text
Backfill shall be placed against both sides of the foundation wall or
AutoCAD SHX Text
be used as backfill within 3 feet of the foundation walls.
AutoCAD SHX Text
Excavations, foundation bearing strata, retaining wall backfill, and
AutoCAD SHX Text
compacted fill shall be observed and approved by a registered soils engineer.
AutoCAD SHX Text
ducts, etc. relating to mechanical, electrical and architectural work
AutoCAD SHX Text
The contractor shall verify locations, and dimensions of slots, anchors,
AutoCAD SHX Text
before pouring concrete.
AutoCAD SHX Text
1)
AutoCAD SHX Text
5)
AutoCAD SHX Text
Design Loads are as follows:
AutoCAD SHX Text
Flat Roof Snow Load = 30 psf
AutoCAD SHX Text
Ground Snow Load = 20 psf
AutoCAD SHX Text
architect before proceeding with the affected part of the work.
AutoCAD SHX Text
discrepancies shall be brought to the attention of the engineer and
AutoCAD SHX Text
All dimensions and conditions must be verified in the field. Any
AutoCAD SHX Text
Structural drawings shall be used in conjunction with job specifications
AutoCAD SHX Text
drawings for sleeves, depressions, and other details not shown on the
AutoCAD SHX Text
and architectural, mechanical, electrical, and civil drawings. Consult these
AutoCAD SHX Text
1)
AutoCAD SHX Text
2)
AutoCAD SHX Text
structural drawings.
AutoCAD SHX Text
Wind Live Load = per IBC 2015. Vult = 130 mph basic wind speed
AutoCAD SHX Text
#19-1096 dated 11-04-2019 indicating an allowable soil bearing pressure of 1,000 p.s.f.
AutoCAD SHX Text
(20 p.s.f. min.), Exposure C
AutoCAD SHX Text
Plywood walls shall be constructed with all panel edges solidly blocked
AutoCAD SHX Text
with matching 2x members. Nail with 10d @ 4" oc at all panel edges,
AutoCAD SHX Text
10" oc at field. Plywood shall be 1/2" Structural II C-D with exterior
AutoCAD SHX Text
glue or equivalent wafer board product. Span Rating 24/0.
AutoCAD SHX Text
manufacturer and shall be designed for all end reactions and bearing
AutoCAD SHX Text
for mechanical items. Joist hangers shall be supplied by the roof truss
AutoCAD SHX Text
shall indicate all bracing, bridging, openings, header joist, and provisions
AutoCAD SHX Text
Shop drawings shall be submitted for roof trusses. Shop drawings
AutoCAD SHX Text
to fabrication with a seal from a professional engineer from the State
AutoCAD SHX Text
of Colorado. Included in these drawings shall be a plan showing the
AutoCAD SHX Text
Supplier of pre-engineered trussed shall furnish to the architect prior
AutoCAD SHX Text
The design and supply of all truss-to-truss connections shall be the
AutoCAD SHX Text
location of the trusses with the suppliers mark.
AutoCAD SHX Text
responsibility of the truss supplier.
AutoCAD SHX Text
conditions.
AutoCAD SHX Text
10)
AutoCAD SHX Text
12)
AutoCAD SHX Text
11)
AutoCAD SHX Text
9)
AutoCAD SHX Text
Floor sheathing shall be 3/4" tongue and groove plywood (or OSB).
AutoCAD SHX Text
Flooring shall be glued at joists and blocking.
AutoCAD SHX Text
Nailing shall be with 8d screw shank nails, 6" oc at edges and 10" oc
AutoCAD SHX Text
at intermediate members. Span Rating 48/24.
AutoCAD SHX Text
13)
AutoCAD SHX Text
Joist and Rafters.........................................Hem-fir No. 2 grade or better
AutoCAD SHX Text
be nailed together to form a single, composite unit. Use no less than two
AutoCAD SHX Text
All multiple headers, beams, and posts made from framing lumber shall
AutoCAD SHX Text
diameter thru bolts spaced at 24" oc. Bolt holes shall be 1/2" in diameter
AutoCAD SHX Text
and located 2" from the top and bottom of the members. Stagger rows
AutoCAD SHX Text
For built-up LVL members connect multiple members using 2 rows of 1/2"
AutoCAD SHX Text
Provide solid blocking between joists and rafters at supports.
AutoCAD SHX Text
equivalent wafer board product. Nail with 10d at 6" oc at panel edges,
AutoCAD SHX Text
Roof sheathing shall be 1/2" APA rated exterior plywood, or an
AutoCAD SHX Text
both ends of cross-bridging. Space bridging as required by code.
AutoCAD SHX Text
bridging 2" thick by depth of joist. End nail solid bridging to joist. Nail
AutoCAD SHX Text
exceeds 5 with bevel-cut double cross wood bracing, or with solid
AutoCAD SHX Text
Bridge between joists or rafters where nominal depth to thickness ratio
AutoCAD SHX Text
Ledgers........................................................Hem-fir No. 2 grade or better
AutoCAD SHX Text
2x wall studs...............................................Hem-fir No. 2 grade or better
AutoCAD SHX Text
and provide a minimum of 2 bolts at each end of members.
Flexural tension or compression...................2600 psi
AutoCAD SHX Text
LVL members shall have the following allowable stresses:
AutoCAD SHX Text
Modules of Elasticity.....................................1,800,000 psi
AutoCAD SHX Text
Compression perpendicular to the grain.......750 psi
AutoCAD SHX Text
Compression parallel to grain.......................2460 psi
AutoCAD SHX Text
and 12" oc at intermediate members. Span Rating 32/16.
AutoCAD SHX Text
Joists and Rafters........................................By truss-joist or equal
AutoCAD SHX Text
Lumber framing members shall conform to the following grades/species:
AutoCAD SHX Text
All lumber shall be visually graded and have a maximum moisture content
AutoCAD SHX Text
Specification for Stress Grade Lumber and its Fastenings", latest edition,
AutoCAD SHX Text
All wood framing materials shall conform to the "National Design
AutoCAD SHX Text
and to the "Uniform Building Code", latest edition.
AutoCAD SHX Text
8)
AutoCAD SHX Text
7)
AutoCAD SHX Text
rows of 16d at 12" oc.
AutoCAD SHX Text
4)
AutoCAD SHX Text
5)
AutoCAD SHX Text
6)
AutoCAD SHX Text
of 19%.
AutoCAD SHX Text
1)
AutoCAD SHX Text
2)
AutoCAD SHX Text
3)
AutoCAD SHX Text
LOT COVERAGE
AutoCAD SHX Text
SITE SQUARE FOOTAGE: 9690 S,F,
AutoCAD SHX Text
PROPOSED FOOTPRINT COVERAGE:
AutoCAD SHX Text
MAIN HOUSE:1,800 S.F.1,800 S.F.
AutoCAD SHX Text
DETACHED GARAGE: 477 S.F. 477 S.F.
AutoCAD SHX Text
TOTAL:2,277 S.F.2,277 S.F.
AutoCAD SHX Text
PERCENTAGE OF COVERAGE: 23% = 23%max. = OK
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
PLAN -
AutoCAD SHX Text
1
AutoCAD SHX Text
A1.00
AutoCAD SHX Text
SITE
AutoCAD SHX Text
SCALE: 1:10
AutoCAD SHX Text
0
AutoCAD SHX Text
SCALE: 1" =
AutoCAD SHX Text
10
AutoCAD SHX Text
20
AutoCAD SHX Text
10'
AutoCAD SHX Text
ISSUE
AutoCAD SHX Text
SHEET:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DRN. BY:
AutoCAD SHX Text
REVISIONS:
AutoCAD SHX Text
PROJECT NO.
AutoCAD SHX Text
john@jpnarch.com (719) 632-1781 fax
AutoCAD SHX Text
1626 E. Pikes Peak, Colorado Springs, CO 80909 Phone: (719) 632-3384
AutoCAD SHX Text
L. ROSS
AutoCAD SHX Text
1-24-2020
AutoCAD SHX Text
PROPERTY OWNER: DANAH R. MARTIN DANAH R. MARTIN ADDRESS: 1730 SPRUCE LANE, COLORADO SPRINGS1730 SPRUCE LANE, COLORADO SPRINGSCOLORADO, 80906-5722 ASSESSOR # 7502204012 7502204012 ZONING: RS-20000 RS-20000 LOT SIZE: .22AC 9,690 SQUARE FEET .22AC 9,690 SQUARE FEET BUILDING SIZE: PROPOSED ADDITION TO AN EXISTING PROPOSED ADDITION TO AN EXISTING 2 STORY RESIDENCE - 2775 S.F. SOILS REPORT: GEOQUEST, #19-1096 11-04-2019 GEOQUEST, #19-1096 11-04-2019 PLAT NO: 716 716 LEGAL DESCRIPTION: LOT 3 AND ST ADJ BLK 3 DIXON HEIGHTSLOT 3 AND ST ADJ BLK 3 DIXON HEIGHTS
AutoCAD SHX Text
VICINITY MAP
AutoCAD SHX Text
PROJECT DESCRIPTION:
AutoCAD SHX Text
NTS
AutoCAD SHX Text
THE PROJECT CONSISTS OF AN ADDITION AND REMODEL TO AN EXISTING SINGLE FAMILY RESIDENCE LOCATED AT 1730 SPRUCE LN. REFER TO VICINITY MAP FOR PROPERTY LOCATION.
AutoCAD SHX Text
PROJECT SITE
AutoCAD SHX Text
SHEET INDEX
AutoCAD SHX Text
A1.00 - TITLE+SITE PLAN A1.10 - DEMO PLAN - DEMO PLAN A2.00 - FLOOR PLANS A3.00 - ELEVATIONS
parcel 9,400 sf (per EPC Assessor) main house 1,800 sf (per builder) detached garage 480 sf (per EPC Assessor) total lot coverage 2280 sf pct lot coverage 24.25% max allowed lot coverage 23% per BOA-16-002
EL PASO ZONING
Text Box
ADDITION - Denied addition to existing SFD; legal non-conforming lot. Placement of proposed addition exceeds previously approved variances for side yard setback of 11'-8" and maximum lot coverage of 23% (reference BOA162 and ADD1623). In addition, requirements for BOA162 Condition # 1 are not being met. Applicant must contact EPC PCD Planner-Of-The-Day at 719-520-6300 to request additional variances from LDC regulations for RS-20000 zoning district side yard setback and lot coverage. Also request planner to confirm if proposed upper level architectural plan for family/guest requires an "Accessory Living Quarters" affidavit process as well.