Certificate of AnalysisLIMONCELLO CBD 550MG CLOUD TINCTUREHarvest/Lot ID: # HMLCV55099Batch#: LCV55099
Page 1 of 4
Highmerica LLC.9500 nw 79 ave HialeahFlorida, United States 330163055025985highmericacbd@gmail.com
SAMPLE:DA90910019-006Sample is BELOW 0.3% THCRetail Product Size : 30 ml
Total Weight: 30 mlOrdered: 09/09/19 Sampled:09/09/19
Completed: 09/13/19 Expires: 09/13/20
Image Safety
Pesticides - PassedMicrobials - NOT TestedMycotoxins - NOT TestedHeavy Metals - PassedTerpenes - NOT TestedResidual-Solvents - NOT TestedFilth - NOT TestedWater Activity - NOT TestedMoisture - NOT Tested
Cannabinoids
0.00%Total THC
2.769%Total CBD
CannabinoidsAnalyte Weight(%) mg/gD9-THC ND ND
THCA ND ND
CBD 2.769 27.690
CBDA ND ND
CBN ND ND
CBDV ND ND
D8-THC ND ND
THCV ND ND
CBG ND ND
CBGA ND ND
CBC ND ND
TOTAL THC ND ND
TOTAL CBD 2.769 27.690
ND ND2.769
ND ND ND ND ND ND ND ND ND2.769
D9-THC THCa CBD CBDa CBN CBDV D8-THC THCV CBG CBGa CBC Total THC Total CBD
4131 SW 47th AVENUE SUITE1408DAVIE, FL 333141-954-368-7664info@eviolabsfl.com ___________________
Jorge SegredoLab Director
State License # n/aISO Accreditation #97164
This report shall not be reproduced, unless in its entirety, without written approval from EVIO Labs. This report is an EVIO Labs certification. The results relate only to the material or product analyzed.Test results are confidential unless explicitly waived otherwise. Void after 1 year from test end date. Cannabinoid content of batch material may vary depending on sampling error. IC=In-control QCparameter, NC=Non-controlled QC parameter, ND=Not Detected, NA=Not Analyzed, ppm=Parts Per Million, ppb=Parts Per Billion. Limit of Detection (LoD) and Limit Of Quantitation (LoQ) are termsused to describe the smallest concentration that can be reliably measured by an analytical procedure. RPD=Reproducibility of two measurements. Action Levels are State determined thresholds forhuman safety for consumption and/or inhalation.
Certificate of AnalysisLIMONCELLO CBD 550MG CLOUD TINCTUREHarvest/Lot ID: # HMLCV55099Batch#: LCV55099
Page 2 of 4
Highmerica LLC.9500 nw 79 ave HialeahFlorida, United States 330163055025985highmericacbd@gmail.com
SAMPLE:DA90910019-006Sample is BELOW 0.3% THCRetail Product Size : 30 ml
Total Weight: 30 mlOrdered: 09/09/19 Sampled:09/09/19
Completed: 09/13/19 Expires: 09/13/20
Pesticides LOQ Action Level Units ResultDIMETHOATE 0.01 0.05 ppm NDABAMECTIN B1A 0.02 0.1 ppm NDPENTACHLORONITROBENZENE 0.01 0.2 ppm NDMETHYL PARATHION 0.05 0.2 ppm NDCYFLUTHRIN 0.05 1 ppm NDCIS-PERMETHRIN 0.05 0.1 ppm NDACEPHATE 0.01 0.1 ppm NDDIMETHOMORPH 0.005 0.05 ppm NDETHOPROPHOS 0.01 0.05 ppm NDACEQUINOCYL 0.05 0.1 ppm NDACETAMIPRID 0.01 0.05 ppm NDETOFENPROX 0.01 0.05 ppm NDALDICARB 0.02 0.05 ppm NDETOXAZOLE 0.01 0.05 ppm NDAZOXYSTROBIN 0.01 0.05 ppm NDFENHEXAMID 0.01 0.1 ppm NDBIFENAZATE 0.01 0.1 ppm NDFENOXYCARB 0.01 0.05 ppm NDFENPYROXIMATE 0.01 0.5 ppm NDBIFENTHRIN 0.01 0.1 ppm NDCARBARYL 0.01 ppm NDFIPRONIL 0.02 0.05 ppm NDFLONICAMID 0.01 0.4 ppm NDCARBOFURAN 0.01 ppm NDCHLORANTRANILIPROLE 0.01 ppm NDFLUDIOXONIL 0.01 0.1 ppm NDHEXYTHIAZOX 0.01 0.25 ppm NDCHLORFENAPYR 0.01 0.05 ppm NDIMAZALIL 0.01 0.05 ppm NDCHLORPYRIFOS 0.01 0.1 ppm NDIMIDACLOPRID 0.01 0.1 ppm NDCLOFENTEZINE 0.01 0.2 ppm NDKRESOXIM-METHYL 0.01 0.1 ppm ND
Pesticides LOQ ActionLevel
Units Result
COUMAPHOS 0.005 0.05 ppm NDMALATHION 0.01 0.05 ppm NDCYPERMETHRIN 0.02 0.5 ppm NDDAMINOZIDE 0.02 0.5 ppm NDMETALAXYL 0.01 0.05 ppm NDDICHLORVOS 0.05 0.1 ppm NDMETHIOCARB 0.01 0.05 ppm NDMETHOMYL 0.01 0.1 ppm NDDIAZANON 0.01 0.05 ppm NDMEVINPHOS 0.01 0.05 ppm NDMYCLOBUTANIL 0.01 0.1 ppm NDNALED 0.01 0.25 ppm NDOXAMYL 0.01 0.25 ppm NDPACLOBUTRAZOL 0.01 0.05 ppm NDTRANS-PERMETHRIN 0.05 0.1 ppm NDPHOSMET 0.01 0.1 ppm NDPIPERONYL BUTOXIDE 0.01 3 ppm NDPRALLETHRIN 0.05 0.1 ppm NDPROPICONAZOLE 0.01 0.1 ppm NDPROPOXUR 0.01 0.1 ppm NDPYRETHRIN I 0.01 0.5 ppm NDPYRIDABEN 0.01 0.2 ppm NDSPINOSAD (SPINOSYN A) 0.01 0.1 ppm NDSPINOSAD (SPINOSYN D) 0.01 0.1 ppm NDSPIROMESIFEN 0.01 0.1 ppm NDSPIROTETRAMAT 0.02 0.1 ppm NDSPIROXAMINE 0.01 0.05 ppm NDTEBUCONAZOLE 0.01 0.05 ppm NDTHIACLOPRID 0.01 0.05 ppm NDTHIAMETHOXAM 0.01 0.05 ppm NDTRIFLOXYSTROBIN 0.01 0.1 ppm ND
4131 SW 47th AVENUE SUITE1408DAVIE, FL 333141-954-368-7664info@eviolabsfl.com ___________________
Jorge SegredoLab Director
State License # n/aISO Accreditation #97164
This report shall not be reproduced, unless in its entirety, without written approval from EVIO Labs. This report is an EVIO Labs certification. The results relate only to the material or product analyzed.Test results are confidential unless explicitly waived otherwise. Void after 1 year from test end date. Cannabinoid content of batch material may vary depending on sampling error. IC=In-control QCparameter, NC=Non-controlled QC parameter, ND=Not Detected, NA=Not Analyzed, ppm=Parts Per Million, ppb=Parts Per Billion. Limit of Detection (LoD) and Limit Of Quantitation (LoQ) are termsused to describe the smallest concentration that can be reliably measured by an analytical procedure. RPD=Reproducibility of two measurements. Action Levels are State determined thresholds forhuman safety for consumption and/or inhalation.
Certificate of AnalysisLIMONCELLO CBD 550MG CLOUD TINCTUREHarvest/Lot ID: # HMLCV55099Batch#: LCV55099
Page 3 of 4
Highmerica LLC.9500 nw 79 ave HialeahFlorida, United States 330163055025985highmericacbd@gmail.com
SAMPLE:DA90910019-006Sample is BELOW 0.3% THCRetail Product Size : 30 ml
Total Weight: 30 mlOrdered: 09/09/19 Sampled:09/09/19
Completed: 09/13/19 Expires: 09/13/20
Cannabinoid Profile Test Result-Analysis Method :SOP.T.40.020, SOP.T.30.050 Analytical Batch:DA006206
Reagent LOT ID Dilution Consumables Id091019.R06 40 76124-662091019.R01 SFN-BX-1025
Reagent LOT ID Dilution Consumables Id090619.R04 849C4-849AK090619.R03 840C6-840H
Full spectrum cannabinoid analysis utilizing High Performance Liquid Chromatography with UV detection (HPLC-UV). (Method: SOP.T.30.050 for sample prep and Shimadzu High Sensitivity MethodSOP.T.40.020 for analysis. LOQ for all cannabinoids is 1 mg/L).
4131 SW 47th AVENUE SUITE1408DAVIE, FL 333141-954-368-7664info@eviolabsfl.com ___________________
Jorge SegredoLab Director
State License # n/aISO Accreditation #97164
This report shall not be reproduced, unless in its entirety, without written approval from EVIO Labs. This report is an EVIO Labs certification. The results relate only to the material or product analyzed.Test results are confidential unless explicitly waived otherwise. Void after 1 year from test end date. Cannabinoid content of batch material may vary depending on sampling error. IC=In-control QCparameter, NC=Non-controlled QC parameter, ND=Not Detected, NA=Not Analyzed, ppm=Parts Per Million, ppb=Parts Per Billion. Limit of Detection (LoD) and Limit Of Quantitation (LoQ) are termsused to describe the smallest concentration that can be reliably measured by an analytical procedure. RPD=Reproducibility of two measurements. Action Levels are State determined thresholds forhuman safety for consumption and/or inhalation.
Certificate of AnalysisLIMONCELLO CBD 550MG CLOUD TINCTUREHarvest/Lot ID: # HMLCV55099Batch#: LCV55099
Page 4 of 4
Highmerica LLC.9500 nw 79 ave HialeahFlorida, United States 330163055025985highmericacbd@gmail.com
SAMPLE:DA90910019-006Sample is BELOW 0.3% THCRetail Product Size : 30 ml
Total Weight: 30 mlOrdered: 09/09/19 Sampled:09/09/19
Completed: 09/13/19 Expires: 09/13/20
Pesticide Analysis-Analysis Method:SOP.T.30.065, SOP.T.40.065 Analytical Batch :DA006221Reagent LOT/ID Dilution Consumables ID
10
Reagent LOT/ID Dilution Consumables ID
Pesticide screen is performed using LC-MS which can screen down to below single digit ppb concentrations for regulated Pesticides. Currently we analyze for 57 Pesticides. (Method: SOP.T.30.065 SamplePreparation for Pesticides Analysis via LCMSMS and SOP.T40.065 Procedure for Pesticide Quantification Using LCMS).Heavy Metals Analysis-Analysis-Method:SOP.T.40.050, SOP.T.30.052 Analytical Batch: DA006209Reagent LOT/ID Dilution Consumables ID
50
Reagent LOT/ID Dilution Consumables ID
Heavy Metals screening is performed using ICP-MS (Inductively Coupled Plasma – Mass Spectrometer) which can screen down to below single digit ppb concentrations for regulated heavy metals usingMethod SOP.T.30.052 Sample Preparation for Heavy Metals Analysis via ICP-MS and SOP.T.40.050 Heavy Metals Analysis via ICP-MS.Metal Result Action-LevelARSENIC ND 0.2CADMIUM ND 0.2LEAD ND 0.5MERCURY ND 0.1
Abbreviation:ppm=Parts Per Million
4131 SW 47th AVENUE SUITE1408DAVIE, FL 333141-954-368-7664info@eviolabsfl.com ___________________
Jorge SegredoLab Director
State License # n/aISO Accreditation #97164
This report shall not be reproduced, unless in its entirety, without written approval from EVIO Labs. This report is an EVIO Labs certification. The results relate only to the material or product analyzed.Test results are confidential unless explicitly waived otherwise. Void after 1 year from test end date. Cannabinoid content of batch material may vary depending on sampling error. IC=In-control QCparameter, NC=Non-controlled QC parameter, ND=Not Detected, NA=Not Analyzed, ppm=Parts Per Million, ppb=Parts Per Billion. Limit of Detection (LoD) and Limit Of Quantitation (LoQ) are termsused to describe the smallest concentration that can be reliably measured by an analytical procedure. RPD=Reproducibility of two measurements. Action Levels are State determined thresholds forhuman safety for consumption and/or inhalation.