Reporting Limit 10 ppm *Total CBD = CBD + CBDA x 0.877 N/D - Not Detected, B/LOQ - Below Limit of Quantification

CERTIFICATE OF ANALYSISISO/IEC 17025:2017 ACCREDITATION #103104

Order #: 44073Order Name: Organic CBDMCT OilBatch#: 1092019MCT12Received: 12/17/2019Completed: 12/20/2019

Upstate Elevator Supply Co.388 Pine St. Suite 2Burlington VT, 05401(888) 640-2155info@upstateelevator.com

Sample

0.243% D9-THC

7.017% Total CBD

Cannabinoids TestSHIMADZU INTEGRATED UPLC-PDAGSL SOP 400 PREPARED: 12/17/2019 13:04:18 UPLOADED: 12/18/2019 08:58:11 Cannabinoids LOQ weight(%) mg/gD9-THC 10 PPM 0.243% 2.430THCA 10 PPM N/D N/DCBD 10 PPM 7.004% 70.041CBDA 20 PPM 0.015% 0.151CBDV 20 PPM 0.026% 0.265CBC 10 PPM 0.482% 4.818CBN 10 PPM N/D N/DCBG 10 PPM 0.117% 1.174CBGA 20 PPM N/D N/DD8-THC 10 PPM N/D N/DTHCV 10 PPM N/D N/D

TOTAL D9-THC 0.243% 0.243%TOTAL CBD* 7.017% 70.173TOTAL CANNABINOIDS 7.887% 78.879

Green Scientific Labs uses its best efforts to deliver high quality results and to verify that the data contained therein are based on sound scientific judgment and levels listed are guidelines only and all data wasreported based on standard laboratory procedures and deviations. However Green Scientific Labs makes no warranties or claims to that effect and further shall not be liable for any damage or misrepresentation thatmay result from the use or misuse of the data contained herein in any way. Further, Green Scientific Labs makes no claims regarding representations of the analyzed sample to the larger batch from which it wastaken. Data and information in this report are intended solely for the individual(s) for whom samples were submitted and as part of our strict confidentiality policy, Green Scientific Labs can only discuss results withthe original client of record.

PESTICIDE ANALYSIS:GSL SOP 401 PREPARED: 12/17/2019 12:54:16 UPLOADED: 12/18/2019 15:30:03

N/D = Not Detected, A/LOQ = Above LOQ Level, B/LOQ = Below LOQ Level, B/LOD = Below LOD Level

CERTIFICATE OF ANALYSISISO/IEC 17025:2017 ACCREDITATION #103104

Order #: 44073Order Name: Organic CBDMCT OilBatch#: 1092019MCT12Received: 12/17/2019Completed: 12/20/2019

Upstate Elevator Supply Co.388 Pine St. Suite 2Burlington VT, 05401(888) 640-2155info@upstateelevator.com

GCMS-MS - Shimadzu GCMS-TQ8040

Pesticide Action Level(ppm)

Results(ppm)

LOQ(ppm)

LOD(ppm)

FIPRONIL 0.100 N/D 0.003 0.001

Pesticide Action Level(ppm)

Results(ppm)

LOQ(ppm)

LOD(ppm)

FLUDIOXONIL 0.100 N/D 0.003 0.001

LCMS-MS - Shimadzu LCMS-8060

Pesticide Action Level(ppm)

Results(ppm)

LOQ(ppm)

LOD(ppm)

ABAMECTIN B1A 0.100 N/D 0.005 0.001ACEPHATE 0.100 N/D 0.001 0.001ACEQUINOCYL 0.100 N/D 0.001 0.001ACETAMIPRID 0.100 N/D 0.005 0.001ALDICARB 0.100 N/D 0.005 0.001AZOXYSTROBIN 0.100 N/D 0.001 0.001BIFENAZATE 0.100 N/D 0.005 0.001BIFENTHRIN 3.000 N/D 0.005 0.001BOSCALID 0.100 N/D 0.005 0.001CARBARYL 0.500 N/D 0.003 0.001CARBOFURAN 0.100 N/D 0.001 0.001CHLORANTRANILIPROLE 10.000 N/D 0.005 0.005CHLORPYRIFOS 0.100 N/D 0.001 0.001CLOFENTEZINE 0.100 N/D 0.001 0.001DAMINOZIDE 0.100 N/D 0.005 0.001DIAZANON 0.100 N/D 0.001 0.001DICHLORVOS 0.100 N/D 0.005 0.001DIMETHOATE 0.100 N/D 0.001 0.001DIMETHOMORPH 2.000 N/D 0.005 0.001ETHOPROPHOS 0.100 N/D 0.001 0.001ETOFENPROX 0.100 N/D 0.001 0.001ETOXAZOLE 0.100 N/D 0.010 0.005FENHEXAMID 0.100 N/D 0.005 0.001FENOXYCARB 0.100 N/D 0.005 0.001FENPYROXIMATE 0.100 N/D 0.001 0.001FLONICAMID 0.100 N/D 0.025 0.010HEXYTHIAZOX 0.100 N/D 0.005 0.001IMAZALIL 0.100 N/D 0.005 0.001

Pesticide Action Level(ppm)

Results(ppm)

LOQ(ppm)

LOD(ppm)

IMIDACLOPRID 5.000 N/D 0.005 0.001KRESOXIM-METHYL 0.100 N/D 0.010 0.005MALATHION 0.500 N/D 0.005 0.001METALAXYL 2.000 N/D 0.001 0.001METHIOCARB 0.100 N/D 0.005 0.001METHOMYL 1.000 N/D 0.001 0.001MEVINPHOS 0.100 N/D 0.001 0.001MYCLOBUTANIL 0.100 N/D 0.005 0.001NALED 0.100 N/D 0.005 0.001OXAMYL 0.500 N/D 0.001 0.001PACLOBUTRAZOL 0.100 N/D 0.005 0.001PERMETHRINS 0.500 N/D 0.005 0.001PHOSMET 0.100 N/D 0.005 0.001PIPERONYLBUTOXIDE

3.000 N/D 0.001 0.001

PRALLETHRIN 0.100 N/D 0.005 0.005PROPICONAZOLE 0.100 N/D 0.010 0.005PROPOXUR 0.100 N/D 0.001 0.001PYRETHRINS(PYRETHRIN I)

0.500 N/D 0.005 0.005

PYRIDABEN 0.100 N/D 0.005 0.001SPINETORAM 0.100 N/D 0.001 0.001SPINOSAD 0.100 N/D 0.001 0.001SPIROMESIFEN 0.100 N/D 0.005 0.001SPIROTETRAMAT 0.100 N/D 0.001 0.001SPIROXAMINE 0.100 N/D 0.001 0.001TEBUCONAZOLE 0.100 N/D 0.005 0.001THIACLOPRID 0.100 N/D 0.001 0.001THIAMETHOXAM 5.000 N/D 0.001 0.001TRIFLOXYSTROBIN 0.100 N/D 0.001 0.001

Green Scientific Labs uses its best efforts to deliver high quality results and to verify that the data contained therein are based on sound scientific judgment and levels listed are guidelines only and all data wasreported based on standard laboratory procedures and deviations. However Green Scientific Labs makes no warranties or claims to that effect and further shall not be liable for any damage or misrepresentation thatmay result from the use or misuse of the data contained herein in any way. Further, Green Scientific Labs makes no claims regarding representations of the analyzed sample to the larger batch from which it wastaken. Data and information in this report are intended solely for the individual(s) for whom samples were submitted and as part of our strict confidentiality policy, Green Scientific Labs can only discuss results withthe original client of record.

CERTIFICATE OF ANALYSISISO/IEC 17025:2017 ACCREDITATION #103104

Order #: 44073Order Name: Organic CBDMCT OilBatch#: 1092019MCT12Received: 12/17/2019Completed: 12/20/2019

Upstate Elevator Supply Co.388 Pine St. Suite 2Burlington VT, 05401(888) 640-2155info@upstateelevator.com

Microbial Analysis:PCR - Agilent AriaMX

Microbial Analysis GSL SOP 406 Uploaded: 12/20/2019 17:35:55

Test Test MethodUsed Device Used LOD Allowable Criteria Actual

Result Pass/Fail

STEC E.COLI* USP 61/62† ARIAMX PCR 2 COPIES OF DNA PRESENCE / ABSENTBELOW

LODPASS

SALMONELLA* USP 61/62† ARIAMX PCR 5 COPIES OF DNA PRESENCE / ABSENTBELOW

LODPASS

ASPERGILLUS USP 61/62† ARIAMX PCR ASP_LOD*** PRESENCE / ABSENTBELOW

LODPASS

† USP 61 (enumeration of bacteria TAC, TYM, and ENT/Coliform), USP 62 (identifying specific species E.coli Aspergillus etc) * STEC and Salmonella run as Multiplex *** Flavus = 2 Copies of DNA / Fumigatis = 2 Copies of DNA Niger = 20 Copies of DNA / Terrus = 10 copies of DNA

Green Scientific Labs uses its best efforts to deliver high quality results and to verify that the data contained therein are based on sound scientific judgment and levels listed are guidelines only and all data wasreported based on standard laboratory procedures and deviations. However Green Scientific Labs makes no warranties or claims to that effect and further shall not be liable for any damage or misrepresentation thatmay result from the use or misuse of the data contained herein in any way. Further, Green Scientific Labs makes no claims regarding representations of the analyzed sample to the larger batch from which it wastaken. Data and information in this report are intended solely for the individual(s) for whom samples were submitted and as part of our strict confidentiality policy, Green Scientific Labs can only discuss results withthe original client of record.

CERTIFICATE OF ANALYSISISO/IEC 17025:2017 ACCREDITATION #103104

Order #: 44073Order Name: Organic CBDMCT OilBatch#: 1092019MCT12Received: 12/17/2019Completed: 12/20/2019

Upstate Elevator Supply Co.388 Pine St. Suite 2Burlington VT, 05401(888) 640-2155info@upstateelevator.com

Heavy Metals Analysis:ICP-MS - Shimadzu ICPMS-2030GSL SOP 403 Uploaded: 12/17/2019 19:41:53

Metal Action Level (ppb) Result (ppb)ARSENIC (AS) 200 B/LOQCADMIUM (CD) 200 B/LOQMERCURY (HG) 100 B/LOQLEAD (PB) 500 B/LOQ

Lower Limit of Quantitation (LOQ) is 75 ppb

Green Scientific Labs uses its best efforts to deliver high quality results and to verify that the data contained therein are based on sound scientific judgment and levels listed are guidelines only and all data wasreported based on standard laboratory procedures and deviations. However Green Scientific Labs makes no warranties or claims to that effect and further shall not be liable for any damage or misrepresentation thatmay result from the use or misuse of the data contained herein in any way. Further, Green Scientific Labs makes no claims regarding representations of the analyzed sample to the larger batch from which it wastaken. Data and information in this report are intended solely for the individual(s) for whom samples were submitted and as part of our strict confidentiality policy, Green Scientific Labs can only discuss results withthe original client of record.