Post on 22-Jan-2015
description
Jetse Pettinga Head of ICT Systems Management
Case Study: Putting information at the heart of your business BT 2nd Data Centre
St. Antoniusziekenhuis
Nieuwegein
Oudenrijn
Overvecht
BT 2nd Data Centre 1
BT 2nd Data Centre 2
Blaricum
Nieuwegein
Oudenrijn
Policlinic Houten
Policlinic Vleuterweide
Overvecht
St. Antoniusziekenhuis
Dental Surgery
Utr.-De Meern
BT 2nd Data Centre 3
Blaricum
Nieuwegein
Oudenrijn
Overvecht
Policlinic Houten
Dental Surgery
Utr.-De Meern
Policlinic Vleuterweide
2013
Utrecht
St. Antoniusziekenhuis
BT 2nd Data Centre 4
Blaricum
Nieuwegein
Policlinic Houten
Policlinic
Oudenrijn
Policlinic
Overvecht
Utrecht
2013
St. Antoniusziekenhuis
Dental Surgery
Utr.-De Meern
• 5.500 Employees
• 250 Specialists
• 150 junior Doctors
• 880 Beds
• 550.000 policlinic visits
BT 2nd Data Centre 5
Blaricum
Nieuwegein
Policlinic Houten
Utrecht
3.500 Desktops
600 Servers / 250 Tera Byte
700 Applications
7 * 24 Hours
Policlinic
Oudenrijn
Policlinick
Overvecht
St. Antoniusziekenhuis
Dental Surgery
Utr.-De Meern
•Hospital
- A comprehensive and specialized healthcare
- Top Medical healthcare 7 days a week, 24 hours a day
- Policlinics at 6 locations
- Short waiting lists
- Highly specialized and motivated medical staff and nurses
- The latest treatment techniques and equipment
•Research and Development
•Antonius Academy
What do we offer?
• Ziekenhuis BT 2nd Data Centre 6
Why a second data centre?
• Healthcare process is becoming increasingly reliant of ICT
• Hospital is a 7 x 24 hour business
• Requirements for continuity and availability of ICT services are high
• Laws and regulations
BT 2nd Data Centre 7
• ……. and other institutions
External audits
BT 2nd Data Centre 8
Research NEN7510 February 2010
"Besides the recommendation priority to any of the
identified risks and a plan to implement related measures, a
number of measures in the opinion of TNO have a priority
that would need immediate attention:
"Realize an alternative location for the central computer
room, or reserve capacity as an interim solution within a
commercial datacenter "
Benchmark scenarios EPD - October 2010 "The main improvements at St. Antonius are working with a
continuous improvement in quality-oriented methodology,
provisions for the continuity and contingency of the EHR
system"
Financial Statement Audit "ICT Developments" November 2010 "The Antonius does not have a continuity or disaster recovery and contingency
arrangements for business to continue in case of emergencies. Antonius can
currently only fall back on the backup tapes "
"If by an emergency the systems in Antonius are no longer available, the business
will be hit." The current measures are not sufficient to ensure continuity. The cost to
recreate the environment may be substantially "
"We recommend to ensure that adequate security measures have been taken in the
event of an emergency and periodic testing."
Research NEN7510 February 2010
"Besides the recommendation priority to any of the
identified risks and a plan to implement related measures, a
number of measures in the opinion of TNO have a priority
that would need immediate attention:
"Realize an alternative location for the central computer
room, or reserve capacity as an interim solution within a
commercial datacentre "
Benchmark scenarios EHR - October 2010 "The main improvements at St. Antonius are working with a
continuous improvement in quality-oriented methodology,
provisions for the continuity and contingency of the EHR
system"
Financial Statement Audit "ICT Developments" November 2010 "The Antonius does not have a continuity or disaster recovery and contingency
arrangements for business to continue in case of emergencies. Antonius can
currently only fall back on the backup tapes "
"If by an emergency the systems in Antonius are no longer available, the business
will be hit." The current measures are not sufficient to ensure continuity. The cost to
recreate the environment may be substantially "
"We recommend to ensure that adequate continuity measures have been taken in
the event of an emergency and to test them periodically."
Requirements for external data centre
• National procurement requirements "Shared Server Centre" Santeon (2008 - 2010)
BT 2nd Data Centre 9
Requirements for external data centre
BT 2nd Data Centre 10
1,3 Km
• National procurement requirements "Shared Server Centre" Santeon (2008 - 2010)
• Distance preferably up to 35 km • “…… but at least a Boeing 747 + 10 meters”
Requirements for external data centre
BT 2nd Data Centre 11
1,3 Km
•National procurement requirements "Shared Server Centre" Santeon (2008 - 2010)
• Distance preferably up to 35 km “…… but at least a Boeing 747 + 10 meters”
• Must be monitored and occupied 7 x 24 hours
• Equipped with emergency power, redundant power and cooling
• Redundantly connected with primary data centre with dark fiber
• Maintain our current provider’s fiber ring
• Solution sufficiently scalable to the future
• 24 hours site access by our own IT staff
• Infrastructure only, applications in-house
BT 2nd Data Centre 12
Requirements for external data centre
•National procurement requirements "Shared Server Centre" Santeon (2008 - 2010)
• Distance preferably up to 35 km
• “Telehousing”
Why BT
• Was already on shortlist Santeon (2008-2010)
• Data centre near primary data centre of St. Antonius Hospital
• Good appearance (1st impression facility and people)
• Their offering was the best if you include line cost
• Growth opportunities and continuity into the future
• The offered square meters
BT 2nd Data Centre 13
Technical Infrastructure
BT 2nd Data Centre 14
Overvecht
Oudenrijn
Nieuwegein
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
Managed
1 Gbit Ring
2010
Technical Infrastructure
BT 2nd Data Centre 15
BT Nieuwegein
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
Overvecht
Oudenrijn
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
Managed
1 Gbit Ring
Nieuwegein
2011
Technical Infrastructure
BT 2nd Data Centre 16
BT Nieuwegein
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
Overvecht
Oudenrijn
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
Managed
1 Gbit Ring
Nieuwegein
2011
Technical Infrastructure
BT 2nd Data Centre 17
BT Nieuwegein
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
Overvecht
Oudenrijn
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
Managed
1 Gbit Ring
Nieuwegein
Utrecht (Leidscherijn)
Policlinic
Policlinic 2013
Technical Infrastructure
BT 2nd Data Centre 18
BT Nieuwegein
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
Overvecht
Oudenrijn
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
U ID
1 30 21 10 0SimplexDuplex12
hp ProLiant DL585
Managed
1 Gbit Ring
Nieuwegein
Utrecht (Leidscherijn)
Policlinic
Policlinic
OTV
Overlay Transport Virtualization
(Both Datacentres in the same network)
Fibre
Channel
2013
To Think About
BT 2nd Data Centre 19
• Building your own datacentre is not cheaper
• Power & Cooling (Racks versus Blades versus Location)
• Redundant fiber connections over completely seperated lines
• Take your time and plan it well
Thank You