CARDIOVIT CS-200 Office - Kotisivukone · 2 SCHILLER’s CARDIOVIT CS-200 Offi ce is a powerful...

Post on 21-Jan-2019

216 views 0 download

Transcript of CARDIOVIT CS-200 Office - Kotisivukone · 2 SCHILLER’s CARDIOVIT CS-200 Offi ce is a powerful...

DESIGN

ED

AN

D M

AN U F A C T U R E D

I N S

WIT

ZE

RLA

ND

DESIGN

ED

AN

D M

A N U F A C T U R E D I N

SW

ITZ

ER

LAND

LT Book für inhouse-Druck

Extra Light für Offset-Druck

Exercise testing with maximum freedom

CARDIOVIT CS-200 Office

Omistaja
Stamp

2

SCHILLER’s CARDIOVIT CS-200 Offi ce is a powerful combination of the MS-12 blue, which is a compact, wireless 12-channel ECG amplifi er, and a sophisticated software.

Scalable solutionIrrespective of the size of your practice or hospital, there is no room for compromise when it comes to the quality of diagnostic data. Therefore, the CS-200 Offi ce is individ-ually scalable and expandable.

Maximum fl exibility with standard formatsSCHILLER uses industry-standard commu-nication proto cols, including GDT, HL7, HL7 aECG, DICOM and DICOM Modality Worklist to integrate CS-200 Offi ce into your enviroment and fulfi l the requirements of your daily workfl ows.

12-channel full disclosure

Online auto-matic arrhythmia detection and classifi cation

On-screen wizard

The on-screen wizard guides the new user from fi rst to last stage, one step at a time, highlighting the next available func-tion. Optionally enabled or disabled.

Dynamic test protocol

Let the system suggest the best exercise protocol, based on patient’s age, body weight and questionnaire.

Automatic and immediate arrhythmia detection

Arrhythmia events are detected immediately and classifi ed as they occur during the exercise, and are displayed in red colour in a separate screen area.

CARDIOVIT

CS-200 Office

On-screen R-R meas-urements

Select from different QTc formulas

3

Free to move with wireless ECGWith the introduction of the wireless acquisition module MS-12 blue, SCHILLER provides a new solution that greatly simplifi es ECG acquisition.

• Free to operate in any environment, even in confi ned spaces. Never worry again about cable length!

• Motion artefacts are minimised by eliminating the analogue cable connection.

Clinicians will now be able to focus on what matters the most: patient care and ECG signal quality.

Small …The MS-12 blue weighs only 115 g (batteries included) and fi ts in one hand.

• Easy to move from one room to the other or from bed to bed.

• Sits comfortably on the bed or patient’s body during ECG acquisition.

• Extremely lightweight patient cable minimises motion artefacts and ensures optimal ECG quality.

… but powerful!State-of-the-art technology provides effi cient power management and best performance.

• One battery charge guarantees continuous opera-tion for more than 36 hours.

• With the power-saving mode of the CS-200 Offi ce application, it is even possible to operate the MS-12 blue for more than a week with one battery charge only!

• Operating costs are thus greatly reduced.

Resting ECG

Online exercise

Exercise ECG, offl ine view

MS-12 blueAveraged complex of all 12 leads

Editable interpretation fi eld

Auto STmax during exercise

Editable table of parameters

Easy patient hook-up

With the integrated ECG display, it is easier than ever to check battery status, electrode contact and signal quality during patient hook-up, right at the patient’s bedside.

• Patients can be prepared wherever convenient, inside or outside the ECG room.

• Excellent solution for patients in isolated rooms.

Imagine the possibilities of an acquisition device with ECG display and lead-check capability, independent of any workstation!

AsiaSCHILLER Asia-Pacific / Malaysia52200 Kuala Lumpur, MalaysiaPhone +603 6272 3033Fax +603 6272 2030sales@schiller.com.mywww.schiller-asia.com

AustriaSCHILLER Handelsgesellschaft m.b.H.A-4040 LinzPhone +43 732 709 90 Fax +43 732 757 000sales@schiller.atwww.schiller.at

ChinaAlfred Schiller Medical Equipment Co. Ltd.100015 Beijing, ChinaPhone +86-10-84565453info@schillermedical.comwww.schillermedical.cn

FranceSCHILLER Médical S.A.S.F-67162 Wissembourg/CedexPhone +33 3 88 63 36 00Fax +33 3 88 94 12 82info@schiller.frwww.schiller-medical.com

France (distribution France)SCHILLER France S.A.S.F-77600 Bussy St GeorgesPhone +33 1 64 66 50 00Fax +33 1 64 66 50 10infoschiller@schiller-france.frwww.schiller-france.com

GermanySCHILLER Medizintechnik GmbHD-85622 Feldkirchen b. MünchenPhone +49 89 62 99 81-0Fax +49 89 609 50 90info@schillermed.dewww.schillermed.de

HungarySCHILLER Diamed Ltd.H-1141 BudapestPhone +36 (1) 383-4780 / 460-9491Fax +36 (1) 383-4778sales@schiller.atwww.schiller-hungary.hu

IndiaSCHILLER Healthcare India Pvt. Ltd.Mumbai - 400 001, IndiaPhone +91 22 6152 3333/ 2920 9141Fax +91 22 2920 9142sales@schillerindia.comwww.schillerindia.com

Croatia Schiller medicinski instrumenti d.o.o.10000 ZagrebPhone +385 1 309 66 59Fax +385 1 309 66 60info@schillerzg.hrwww.schiller.ch

Latin AmericaSCHILLER Latin America, Inc.Doral, Florida 33172Phone +1 954 673 0358Fax +1 786 845 06 02sales@schillerla.chwww.schillerla.ch

PolandSCHILLER Poland Sp. z o.o.PL-02-729 WarszawaPhone +48 22 8432089Fax +48 22 8432089schiller@schiller.plwww.schiller.pl

Russia & C.I.S.SCHILLER AG Rep. office125124 Moscow, RussiaPhone +7 (495) 970 11 33Fax +7 (495) 970 11 33mail@schiller-ag.comwww.schiller-cis.com

Serbia SCHILLER d.o.o.11010 BeogradPhone +381 11 39 79 508Fax +381 11 39 79 518info@schiller.rswww.schiller.rs

Slovenia SCHILLER d.o.o.2310 Slovenska BistricaPhone +386 2 843 00 56Fax +386 2 843 00 57info@schiller.siwww.schiller.si

SpainSCHILLER ESPAÑA, S.A.E-28230-Las Rozas/MadridPhone +34 91 713 01 76Fax +34 91 355 79 33schiller@schiller.eswww.schiller.es

SwitzerlandSCHILLER-Reomed AGCH-8953 DietikonPhone +41 44 744 30 00Fax +41 44 740 37 10sales@schiller-reomed.chwww.schiller-reomed.ch

TurkeySCHILLER TÜRKIYEOkmeydani-Sisli – IstanbulPhone +90 212 210 8681 (pbx)Fax +90 212 210 8684sales@schiller-turkiye.comwww.schiller-turkiye.com

USASCHILLER America Inc.Doral, Florida 33172Phone +1 786 845 0620Fax +1 786 845 06 02sales@schilleramerica.comwww.schilleramerica.com

DESIGN

ED

AN

D M

AN U F A C T U R E D

I N S

WIT

ZE

R

LAND

DESIGN

ED

AN

D M

A N U F A C T U R E D I N

SW

ITZ

ER

LAND

LT Book für inhouse-Druck

Extra Light für Offset-Druck

Headquarters: SCHILLER AG, Altgasse 68, CH-6341 Baar, Switzerland, Phone +41 41 766 42 42, Fax +41 41 761 08 80, sales@schiller.ch, www.schiller.ch

Art

icle

no

.: 2.

5006

76 *2.500676*

09

/14,

EN

Omistaja
Stamp