INSTALLATION INSTRUCTIONSCovering frame model numbers:
Frameless Edge Cool Wall
RVS-1FEK Riva Studio 1RVS-2FEK Riva Studio 2 RVS-3FEK Riva Studio 3
RVS-1FCWK Riva Studio 1RVS-2FCWK Riva Studio 2RVS-3FCWK Riva Studio 3
1. GENERAL1.1 These instructions are supplementary to, and must be read
in conjunction with, the Installation Instructions (PM274 for Riva Studio) supplied with the fire.
1.2 Allow for the connection of the following: - Electrical services (for fan installation) using the opening
in the outside of the chimney breast for access. - The Outside Air kit (optional) - Convection Ducting kit (Optional) - The flue system
2. SECURING THE FRAME TO THE FIRE
The fitting of the frame requires 2 people
2.1 To attach the frame: •Lineuptheframewiththeholesontheappliancebody,
Diagram 1.
1
PR8408
Cool Wall
PR8406
Frameless Edge
2.2 Secure the frame to the appliance body using the screws and nuts provided:
Studio 1 - 5x Screws and nuts Studio 2 - 6x Screws and nuts Studio 3 - 8x Screws and nuts (See Diagram 2).
2
PR8795
Cool Wall
PR8794
Frameless Edge
2.3 Build the studwork or brick masonry chimney breast to support the cassette, Diagram 3 & 4. Fit non combustible board to studwork/frame/masonry to finish flush with the front edge of the flange.
This should be done in conjunction with the section on installation of the Edge kit in the Riva Studio Cassette Manual for Installation and Use (Stovax No. PM274).
3
PR8413
PR8411
Frameless Edge
Cool Wall
3
4
PR8412
Heat resistant plaster
Non combustible plasterboard
Flange
2.4 Apply heat resistant plaster to the board cut to the dimensions stated in the Studio Instruction manual (Stovax Part No. PM274).
2.5 To finish this installation: •Re-installtheinnerbox
Frameless Edge & Cool Wall Frames
4
1.2 Fitting of the frame must be carried out after the appliance has been fully installed and commissioning tests completed.
1.3 To fix the brackets see PM274 Installation Instructions. There are multiple brackets to secure the top and bottom of
the frame, see Diagram 2 and table below.
2
PR8480
Top Brackets
Bottom Brackets
Nuts Screws Washers
Studio 1 2 3 7 7 2
Studio 2 3 3 9 9 3
Studio 3 4 4 12 12 4
2. SECURING FRAME TO THE FIRE
The fitting of the frame requires 2 people
2.1 To attach the frame: •Lowerthebottomfixingangleontothebottombrackets
and then slot the top brackets under the top brackets attached to the appliance flange, Diagram 3
3
PR8359
1
2
2.2 Secure the frame to the brackets behind the top of the frame, Diagram 4 & 5
The door must be open or removed (see PM274) to tighten the screws.
USER INSTRUCTIONS
1. CLEANING THE FRAME
Only clean the frame when it is cold.
The painted surfaces of the Flat Steel frame should be cleaned using a damp cloth and buffed with a lint free duster.
INSTALLATION INSTRUCTIONS
Covering the following models:
Model Studio 1 Studio 2 Studio 3
Bauhaus RVS-1FB/RVS1FBP
RVS-2FB/RVS2FBP
RVS-3FB/RVS3FBP
Verve RVS-1FV* RVS-2FV* RVS-3FV*
Flat Steel RVS-1FST* RVS-2FST* RVS-3FST*
Glass RVS-1FGB* RVS-2FGB* RVS-3FGB*
Profil RVS-1FPRO4 RVS-2FPRO4 RVS-3FPRO4
*NOTE: Adding a suffix of HT to these codes allows shipping to a country where packaging must conform to ISPM15.
1. GENERAL
1.1 These instructions are supplementary to, and must be read in conjunction with, the Installation Instructions (PM274 for Riva Studio) supplied with the fire.
Glass Frame Note: Warning - the edges and corners of this product can be
easily damaged during installation. Leave the protective edging on during handling and only remove when fully installed.
Before fitting the frame please ensure correct fixing brackets are attached to the outer box flange.
1
PR8509
Bauhaus, Verve, Flat Steel, Glass & Profil Frames
Bauhaus, Verve, Flat Steel,Glass & Profil Frames
5
5
PR8365
Bottom Bracket
Fix Brackets to Studio flange
See fixing kit lists for the number of brackets used for each model.
4
PR8364Use 4mm Hex Key
See fixing kit lists for the number of brackets used for each model.
Frame Fixing Kits
Image/Description/Code Studio 1
Studio 2
Studio 3
M6 Nut - M06NUTO5 6 8
M6 x 12 Countersunk Screw - M0612CSKSOC
5 6 8
Frameless Edge & Cool Wall Frames Fixing Kit
Image/Description/Code Studio 1
Studio 2
Studio 3
M6 x 16 Button Head Screw - M0616BUTH 2 3 4
M6 Nut - M06NUTO
7 8 8
M6 Washer - M0614WASH
2 2 N/A
M6 x 12 Countersunk Screw - M0612CSKSOC 5 6 8
Top Frame Fixing bracket - MEC8672 2 3 N/A
Top Frame Fixing bracket - MEC8444 N/A N/A 4
Top Frame Fixing bracket - RA502112 2 2 N/A
Frame Fixing bracket - RA502106 3 3 4
Verve Frame Fixing Kit
Continued over...
StovaxLtd,FalconRoad,SowtonIndustrialEstate,Exeter,Devon,EnglandEX27LFTel: (01392) 474011 Fax: (01392) 219932 E-mail: info@stovax.com www.stovax.com
Image/Description/Code Studio 1
Studio 2
Studio 3
M6 x 16 Button Head Screw - M0616BUTH 2 3 4
M6 Nut - M06NUTO
7 9 12
M6 Washer - M0614WASH
2 3 4
M6 x 12 Countersunk Screw - M0612CSKSOC 5 6 8
Top Frame Fixing bracket - MEC8434 2 3
4(Steel
& Glass)
Top Frame Fixing bracket - MEC8444 N/A N/A
4(ProfilOnly)
Top Frame Fixing bracket - RA502099
2 3 N/A
Top Frame Fixing bracket - RA502112 N/A N/A 4
Frame Fixing bracket - RA502106 3 3 N/A
Frame Fixing bracket - RA502122 N/A N/A 4
Steel, Glass & Profil Frame Fixing Kit
Image/Description/Code Studio 1
Studio 2
Studio 3
M6 x 16 Button Head Screw - M0616BUTH 2 3 4
M6 Nut - M06NUTO
5 6 8
Top Frame Fixing bracket - MEC8434 2 3 N/A
Top Frame Fixing bracket - MEC8444 N/A N/A 4
M6 x 12 Countersunk Screw - M0612CSKSOC 5 6 8
Frame Fixing bracket - RA502399
3 3 N/A
Frame Fixing bracket - RA502106 N/A N/A 4
Bauhaus Frame Fixing Kit
Frame Fixing Kits