Post on 23-Aug-2020
© ABB Inc. June 6, 2011 | Slide 1
AWEA Windpower 2011
MV Wind Converter ProductsTop 10 Reasons
© ABB Inc. June 6, 2011 | Slide 2
Speaker name: Arnd BeckerSpeaker title: Business Development ManagerCompany name: ABB Inc.
In booth theater presentationsMV Wind Converter Products – Top 10 Reasons
© ABB Inc. June 6, 2011 | Slide 3
MV Wind Converter Products
© ABB Group June 6, 2011 | Slide 4
Top Reasons for MV Wind- Maximum Energy to the Grid
Typical efficiency for whole electrical drive train (DD with PMSG)
~98% converter efficiency incl. all auxiliaries & filters partial load efficiency >95% already at 10% of rated power
Best MTTR by remote access and special repair concept
© ABB Group June 6, 2011 | Slide 5
Top Reasons for MV Wind- Maximum Generator Control
Generator operation at optimum active and reactive power
Rotor positioning mode (on-site needed for service)
Generator test run (hall test needed for pre-heating, over-speed)
Total over-speed voltage suppression (field weakening)
Active drive train damping leads to lean design of mechanicaldrive train components
© ABB Group June 6, 2011 | Slide 6
Top Reasons for MV Wind- Easy cabling and lowest losses
Easy and quick cabling by the Pfisterer© P3 MV PLUG System
I2R losses significantly lower (>factor 20) compared to 690V system maximum system efficiency
© ABB Group June 6, 2011 | Slide 7
Top Reasons for MV Wind- Full Drive Train Decoupling
Full decoupling of mechanical turbine from the electrical grid
Power dissipation resistors for smooth FRT
Active drive train damping lean design of mechanical components
© ABB Group June 6, 2011 | Slide 8
Top Reasons for MV Wind- Full Grid Code Compliance
Integrated Statcom functionality
Three-level switching topology
Control algorithm harmonic elimination
Start & stop at zero breaker current
Immediate restart after grid failures
© ABB Group June 6, 2011 | Slide 9
Door interlock system connected to DC-link voltage
Remote operated generator breaker incl. manually operated grounding switch
Fuseless design for minimized replacement even after severe component failures firing through concept
Controlled short circuit current distribution incl. transformer design
Top Reasons for MV Wind- Advanced Safety and Repair Concept
© ABB Group June 6, 2011 | Slide 10
Top Reasons for MV Wind- AC 800PEC High End Controller
3-level control strategy
Integrated monitoring & diagnostic tools event-recorder
Operational flexibility by implemented thermal model of main components
Full remote access (to go on-site only once!)
Immediate restart after grid failureblack start capability
Very Fast Applications
(VHDL)
Fast Applications
(MATLAB/Simulink)
Slow Appllications
(ABB Control Builder)
CycleTime
1 ms
100us
25ns
TASK LEVEL
Very Fast Applications
(VHDL)
Fast Applications
(MATLAB/Simulink)
Slow Appllications
(ABB Control Builder)
CycleTime
1 ms
100us
25ns
TASK LEVEL
© ABB Group June 6, 2011 | Slide 11
Power modules, Cooling Unit, all filters, brake chopper (incl. resistor),generator breaker
Various layouts available: face-2-face, back-2-back, I-shape, T-shape
Electrical section in tower less tower head weight / smallerfoundation
Top Reasons for MV Wind- Modular Design - All on one Level
© ABB Group June 6, 2011 | Slide 12
Top Reasons for MV Wind- System Know-how and Global Footprint of ABB
Advanced protection concept includes transformer, switch gear and whole drive train concept
Inclusion of further components into scope of supply
Maximum customer support due to world-wide presence
© ABB Group June 6, 2011 | Slide 13
Top Reasons for MV Wind- Strong Service Organization
ABB Commissioner©: Remote access tool with advanced monitoring and component lifetime calculation assures that your service people know what happens on-site, at all times
Maximum serviceability by customer training concept, lifecycle management, and installed base management
© ABB Group June 6, 2011 | Slide 14
PCS 6000 – Maximum Energy to the Grid
grid filter
PM Gen
dv/dt filter Generator-side converter Grid-side converter
DC link with voltage limiting
unitBreaker
Pre-charging UnitAux. Equipment
(heaters, fans, …) Cooling Unit
M
M
Converter Controller
Turbine Braking Resistor
AC 800 PEC S800 I/OVery Fast I/O
Wind
Par
k Grid
Industrial PC
PCS 6000 MV Full-Power ConverterPrinciple single line diagram
Water Cooling Unit
dv/dt-Filter
Gen.-SideConverter
DC-Link,Chopper
Grid-SideConverter
Grid Filter
Main components:
Optional components:
Generator-breaker
Soft-start unit, anti-condens.
function
Extended resistors for smooth FRT