Single Aisle TECHNICAL TRAINING MANUAL
T1+T2 (CFM 56 / ME) (Lvl 2&3)
APU
8/20/2019 ATA 49 APU
2/238
8/20/2019 ATA 49 APU
3/238
This document must be used for training purposes only
Under no circumstances should this document be used as a reference
It will not be updated.
All rights reserved
No part of this manual may be reproduced in any form,
by photostat, microfilm, retrieval system, or any other means,
without the prior written permission of AIRBUS S.A.S.
8/20/2019 ATA 49 APU
4/238
8/20/2019 ATA 49 APU
5/238
APU
GENERAL
APU Level 2 (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
APU Installation Presentation (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18APU Fuel Feed System D/O (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
HONEYWELL 131-9(A)
APU Drain System Presentation (2) . . . . . . . . . . . . . . . . . . . . . . . . . . 22
APU Basic Description (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
APU Ignition & Starting D/O (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
APU Fuel System D/O (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
APU Oil System D/O (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
APU Air System D/O (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
APU System Management D/O (3) . . . . . . . . . . . . . . . . . . . . . . . . . . 40APU Warnings (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
ECB Interfaces (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
HONEYWELL GTCP 36-300
APU Drain System Presentation (2) . . . . . . . . . . . . . . . . . . . . . . . . . . 72
APU Basic Description (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
APU Ignition & Starting D/O (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
APU Fuel System D/O (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
APU Oil System D/O (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
APU Air System D/O (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
APU System Management D/O (3) . . . . . . . . . . . . . . . . . . . . . . . . . . 90# APU Warnings (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
ECB Interfaces (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
APU Film Presentation (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
APIC
APU Drain System Presentation (2) . . . . . . . . . . . . . . . . . . . . . . . . . 140
APU Basic Description (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
APU Ignition & Starting D/O (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
APU Fuel System D/O (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
APU Oil System D/O (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154
APU Air System D/O (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
APU System Management D/O (3) . . . . . . . . . . . . . . . . . . . . . . . . . 158# APU Warnings (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186
ECB Interfaces (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188
APU Film Presentation (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192
MAINTENANCE PRACTICE
COMPT Access Doors Opening & Closing (2) . . . . . . . . . . . . . . . . 214
APU Removal / Installation (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
TABLE OF CONTENTS Sep 11, 2007
Page 1
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0
8/20/2019 ATA 49 APU
6/238
APU LEVEL 2 (2)
SYSTEM OVERVIEW
The Auxiliary Power Unit (APU) is a constant speed gas turbine engine.
It is located in the unpressurized tail cone. The APU is a self-contained
unit, which enables the aircraft to be independent of external pneumatic
and electrical power sources.
The constant-speed gas turbine engine drives the accessory gearbox and
a load compressor. The APU provides:
- electrical power for the aircraft systems,
- bleed air for engine starting (MES), air conditioning (ECS) and wing
anti ice testing on ground (not GTCP 36-300),
- bleed air for air conditioning and pressurization in flight until the
specified manufacturer limit.
The APU is designed to operate throughout the entire flight envelope.Electrical power is available whenever the APU operates, but bleed air
is shut off above the specified manufacturer limit.
The APU has an air intake flap. The intake flap is open when the APU
master switch is selected ON and closes when the master switch is selected
OFF. When open, it provides air to the APU inlet for combustion and
pneumatic supply.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU LEVEL 2 (2) Sep 17, 2007
Page 2
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49BA000
000001
8/20/2019 ATA 49 APU
7/238
SYSTEM OVERVIEW
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU LEVEL 2 (2) Sep 17, 2007
Page 3
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49BA000
000001
8/20/2019 ATA 49 APU
8/238
APU LEVEL 2 (2)
SERVICING
APU OIL SERVICING
APU oil servicing is accomplished on an "as-needed" basis or after
scheduled oil quantity checks. The oil indicating system shows if the
oil quantity is sufficient or if an oil servicing is necessary.
The oil level information is displayed on the EIS and the Multipurpose
Control & Display Units (MCDUs) in the cockpit on:
- the APU page on the lower ECAM display unit (LOW OIL LEVEL
advisory),
- the APU SERVICE DATA page on the MCDU, indicating APU
OIL Level O.K. or LOW.
NOTE: Note: The advisory appears on the ECAM APU page whenthe oil level has reached the ADD mark on the APU oil tank.
Airbus recommends servicing the APU oil at the next daily
maintenance when the LOW OIL LEVEL message comes on. With
no oil leakage, sufficient oil is available to allow a further 10 hours
of APU operation.
Prior to servicing, shut down the APU and open the APU cowl doors.
Make sure to use the operator approved oil for servicing (operators
may select from the approved list). The oil may be serviced by the
gravity (most common) or pressure fill procedure (optional).
Gravity procedure:
- Open the lock and slowly loosen the oil filler cap to release remaining
pressure from the oil reservoir,
- Check sight glass for level,
- Slowly add oil until the level is at the FULL mark on the sight glass.
Pressure fill procedure:
- Check sight glass for level,
- Connect pressure and overfill lines to APU gearbox,
- Slowly pump oil into the gearbox until the level is at the FULL mark
on the sight glass.
Close and lock the oil filler cap.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU LEVEL 2 (2) Sep 17, 2007
Page 4
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49BA000
000001
8/20/2019 ATA 49 APU
9/238
SERVICING - APU OIL SERVICING
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU LEVEL 2 (2) Sep 17, 2007
Page 5
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49BA000
000001
8/20/2019 ATA 49 APU
10/238
APU LEVEL 2 (2)
SERVICING (continued)
APU COWL DOOR OPENING & CLOSING
The APU cowl doors are secured with three quick-release fasteners
and four shoot bolts. The quick-release fasteners secure the doors
together and the shoot bolts secure the doors to the aircraft structure.
Procedure to open the doors:
- Release the quick-release fasteners,
- Hold the LH door and release the latches of the 2 shoot bolts,
- Open the door and secure it with the telescopic strut,
- Hold the RH door and release the latches of the 2 shoot bolts,
- Open the door and use the control handle to secure the door over
center.
The doors are closed opposite from the opening sequence. The RHdoor is closed and secured first.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU LEVEL 2 (2) Sep 17, 2007
Page 6
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49BA000000001
8/20/2019 ATA 49 APU
11/238
SERVICING - APU COWL DOOR OPENING & CLOSING
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU LEVEL 2 (2) Sep 17, 2007
Page 7
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49BA000000001
8/20/2019 ATA 49 APU
12/238
APU LEVEL 2 (2)
MEL/DEACTIVATION
In case of an APU inlet actuator failure, the APU may be dispatched per
MEL with the inlet OPEN or CLOSED. The APU will only be operational
with the inlet deactivated OPEN (for a maximum of 10 days).
The air inlet actuator is equipped with a manual drive. In case of failure
the manual drive may be used to move the inlet to the required position
prior to deactivation. There are 2 different actuators that may be installed.
One requires 47 turns of the manual drive for one full travel of the inlet.
The other requires 87 turns. Access to the actuator is through an access
door near the APU inlet on the right hand side of the fuselage.
Deactivation procedure:
- get access to the actuator,
- disconnect the actuator electrical connector from the fixed connectoron the frame and install a blanking cap,
- use the manual drive to move the inlet to the required position. Use a
torque wrench to avoid damaging the actuator.
If the inlet is deactivated CLOSED, no further action is needed other than
to placard the APU inoperative. If the inlet is deactivated OPEN, the
following procedure has to be accomplished.
When the inlet is in the OPEN position, a jumper lead needs to be installed
to close the circuit and allow the APU to start. Make a dummy connector
and paint it red for easy identification.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU LEVEL 2 (2) Sep 17, 2007
Page 8
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49BA000000001
8/20/2019 ATA 49 APU
13/238
MEL/DEACTIVATION
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU LEVEL 2 (2) Sep 17, 2007
Page 9
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49BA000000001
8/20/2019 ATA 49 APU
14/238
MEL/DEACTIVATION
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU LEVEL 2 (2) Sep 17, 2007
Page 10
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49BA000000001
8/20/2019 ATA 49 APU
15/238
This Page Intentionally Left Blank
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU LEVEL 2 (2) Sep 17, 2007
Page 11
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49BA000000001
8/20/2019 ATA 49 APU
16/238
APU LEVEL 2 (2)
MAINTENANCE TIPS
The APU fuel supply line is equipped with a drain and vent valve which
enables the line to be purged of air after maintenance. The drain valve islocated in the APU compartment in the fuel supply line to the fuel control.
A switch labeled FUEL VENT PUSH is installed on the APU
compartment forward firewall to allow maintenance to operate the APU
fuel pump and purge the fuel line from the APU compartment. This switch
allows the APU pump to operate and the APU Low Pressure fuel valve
to open without the APU Master Switch ON.
A drain valve adapter tool is connected to the drain valve.
On the front firewall of the APU compartment:
- Push and hold the FUEL VENT pushbutton switch. At the APU fuel
vent and drain valve, a continuous flow of fuel indicates that the APUfuel pump is operating and the line is purged,
- Release the FUEL VENT pushbutton switch. The flow of fuel stops
when the APU fuel pump stops running,
- Disconnect the adapter tool.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU LEVEL 2 (2) Sep 17, 2007
Page 12
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49BA000000001
8/20/2019 ATA 49 APU
17/238
MAINTENANCE TIPS
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU LEVEL 2 (2) Sep 17, 2007
Page 13
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49BA000000001
8/20/2019 ATA 49 APU
18/238
APU LEVEL 2 (2)
MAINTENANCE TIPS (continued)
APU OPERATION WITH COWL DOORS OPEN
If it is necessary to operate the APU for maintenance with the cowls
open, be sure to:
- Make sure the doors are secured in the Open position,
- Be aware of suction at inlet. Small items could be ingested,
- Make sure that proper fire-fighting equipment is available.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU LEVEL 2 (2) Sep 17, 2007
Page 14
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49BA000000001
8/20/2019 ATA 49 APU
19/238
MAINTENANCE TIPS - APU OPERATION WITH COWL DOORS OPEN
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU LEVEL 2 (2) Sep 17, 2007
Page 15
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49BA000000001
8/20/2019 ATA 49 APU
20/238
APU LEVEL 2 (2)
ENVIRONMENTAL PRECAUTIONS
Do not discharge products such as oil, fuel, solvent, lubricant either in
trash bins, soil or into the water network (drains, gutters, rain water, wastewater, etc...).
Sort waste fluids and use specific waste disposal containers.
Each product must be stored in an appropriate and specific cabinet or
room such as a fire-resistant and sealed cupboard.
Avoid use of the APU if APU BLEED air is not necessary. Turn-off
unused ground service equipment (GPU, Air conditioning cart, etc...) if
no work is being done or nobody is present on the aircraft.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU LEVEL 2 (2) Sep 17, 2007
Page 16
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49BA000000001
8/20/2019 ATA 49 APU
21/238
ENVIRONMENTAL PRECAUTIONS
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU LEVEL 2 (2) Sep 17, 2007
Page 17
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49BA000000001
8/20/2019 ATA 49 APU
22/238
APU INSTALLATION PRESENTATION (2)
GENERAL
The Auxiliary Power Unit (APU) is installed in a fireproof COMParTment
(COMPT) located in the fuselage tail cone.
MOUNTS
Seven tie rods attach the APU to the structure brackets on the APU
COMPT ceiling. These tie rods also connect to the APU three-point
mounted suspension system. Vibration isolators are installed between
the APU mount brackets and the tie rods to reduce the transmission of
A/C vibrations and shocks to the APU. The isolators also prevent the
transmission of vibrations from the APU to the A/C structure.
AIR INTAKE FLAP
The air intake system ducts ambient air to the APU plenum chamber. An
air intake flap cuts off the air supply when the APU does not operate. In
case of failure, the air intake flap can be opened or closed manually by
a manual override device.
AIR INTAKE DUCT
The air intake duct, which is composed of a diffuser and elbow, provides
correct airflow to the APU plenum. The air intake duct is attached to the
right access door.
EXHAUST
The exhaust system lets the APU exhaust gas flow into the atmosphere
and muffles the noise from the exhaust. The exhaust muffler thermal
insulation protects the A/C structure.
ACCESS DOORS
Two access doors allow access to the APU COMPT. The access doors
on the bottom of the tail cone open outwards to allow the APU to beinspected, lifted and lowered.
DRAIN SYSTEM
A drain system prevents the collection of fluids in the APU COMPT.
Any fluid that may accumulate in the APU COMPT is delivered to a
drain mast. Some of the fluids are collected in a drain tank in the APU
COMPT, which is emptied through the drain mast when the A/C is above
200 kt.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU INSTALLATION PRESENTATION (2) Sep 17, 2007
Page 18
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49P1000
000001
8/20/2019 ATA 49 APU
23/238
GENERAL ... DRAIN SYSTEM
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU INSTALLATION PRESENTATION (2) Sep 17, 2007
Page 19
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49P1000
000001
8/20/2019 ATA 49 APU
24/238
APU FUEL FEED SYSTEM D/O (3)
GENERAL
The Auxiliary Power Unit (APU) fuel feed system is used to provide fuel
necessary for correct APU operation. This system is composed of:- fuel pump (115V AC, 400Hz, single phase),
- LP valve,
- APU inlet LP switch,
- fuel drain and vent system.
FUEL PUMP
The APU fuel pump is a centrifugal pump driven by a single phase AC
motor. This pump is controlled to run if the APU MASTER SW P/B is
set to ON and the fuel crossfeed line pressure is not sufficient. The fuel
crossfeed line pressure switch controls the operation of the APU fuelpump. The APU fuel pump runs as soon as the pump inlet pressure is
lower than 21.8 psi (1.50 bar). It stops when the pressure is above 23.2
psi (1.60 bar).
FUEL LP VALVE
Two DC motors drive the APU fuel LP valve. This valve is open as long
as the Electronic Control Box (ECB) is powered. When closed, it prevents
pressurization of the APU fuel feed line and flow of fuel into a specific
fire zone. The APU fuel LP valve is automatically closed when:
- the APU MASTER SW P/B has been released out and before ECB isdeenergized,
- the ECB commands a protective shut down in case of abnormal APU
parameters,
- the ECB commands an emergency shut down in case of APU fire or
overheat detection,
- the APU FIRE P/B is released out in the cockpit,
- the APU SHUT OFF P/B has been pressed on the external power control
panel.
APU INLET LP SWITCH
At the inlet connection of the Fuel Control Unit (FCU), a pressure switch
transmits LP information through the ECB to the APU ECAM page. TheFUEL LOw PRessure message is displayed on the APU ECAM page if:
- the APU speed is greater than 7% rpm and the APU is supposed to run,
- the fuel pressure is lower than 15.8 psi (1.01 bar).
The ECB memorizes this information in its BITE memory even if the
pressure increases above 17.3 psi (1.19 bar).
FUEL DRAIN AND VENT SYSTEM
A vent APU fuel line P/B, located on the front firewall allows the APU
fuel feed line to be purged during ground maintenance. As long as the
P/B is held pressed in, the APU fuel LP isolation valve is open and theAPU fuel pump runs. A fuel drain and vent valve is installed in the APU
compartment at the fuel inlet connection to the FCU. It allows fuel to be
drained and air to be bled.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU FUEL FEED SYSTEM D/O (3) Sep 17, 2007
Page 20
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D2000000001
8/20/2019 ATA 49 APU
25/238
GENERAL ... FUEL DRAIN AND VENT SYSTEM
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU FUEL FEED SYSTEM D/O (3) Sep 17, 2007
Page 21
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D2000000001
8/20/2019 ATA 49 APU
26/238
APU DRAIN SYSTEM PRESENTATION (2)
APU DRAIN SYSTEM
A drain system prevents the collection of fluids in the Auxiliary Power
Unit (APU) system and compartment.
FUEL CONTROL UNIT/OIL PUMP SEAL DRAIN
The fuel and oil pump seal drain line is routed via a collector line to the
drain tank. This line drains fuel or oil leaks.
INLET GUIDE VANE ACTUATOR DRAIN
The Inlet Guide Vane (IGV) actuator drain line is routed via the collector
line to the drain tank. This line drains only fuel leaks.
GEARBOX VENT
The oil reservoir has a connection to the ambient air through an air/oil
separator. The gear driven air/oil separator is connected through a gearbox
vent line to the APU exhaust cone.
SURGE CONTROL VALVE DRAIN
The surge control valve fuel is drained into the drain tank by the Fuel
Control Unit (FCU)/IGV actuator common drain line.
LOAD COMPRESSOR CAVITY DRAINTo prevent any ingestion of oil in the bleed system the load compressor
bearing cavities are kept dry by buffering air into the main shaft seals.
An oil leak witness drain is located aft of the seal to collect any oil
leakage. The oil is drained directly overboard through the drain mast.
TURBINE PLENUM DRAIN
A turbine plenum drain orifice is provided to drain fuel that may
accumulate in the combustor following an unsuccessful light-up. Thefuel is drained directly overboard through the drain mast.
EXHAUST MUFFLER DRAIN
The exhaust muffler drain line is routed to the drain mast. This drain line
collects water or cleaning fluid.
APU COMPARTMENT DRAIN
Water coming from rain or condensate humidity, cleaning agents and
any oil and fuel in the compartment, due to leaks or APU servicing, are
drained to the lowest point of the APU door and through the drain mast
overboard.
DRAIN TANK
For venting and evacuation, the drain tank is connected to the drain mast.
Airflow across the drain mast creates a vacuum in the drain line. The
suction effect produced at 200 kts, is sufficient to remove the contents
of the drain tank. A vent line ventilates the drain tank and drain lines.
The APU drain lines are connected to the right access door drain lines
through spring adapter kiss seals.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU DRAIN SYSTEM PRESENTATION (2) Sep 17, 2007
Page 22
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49P2000000001
8/20/2019 ATA 49 APU
27/238
APU DRAIN SYSTEM ... DRAIN TANK
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU DRAIN SYSTEM PRESENTATION (2) Sep 17, 2007
Page 23
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49P2000000001
8/20/2019 ATA 49 APU
28/238
APU BASIC DESCRIPTION (3)
GENERAL
The Auxiliary Power Unit (APU) is of a modular design. The three APU
modules are:- the power section,
- the load compressor,
- the accessory drive gearbox.
ENGINE COMPRESSOR
The compressor is of a single stage centrifugal compressor design. The
main components of the compressor are:
- a single stage centrifugal impeller,
- single stage diffuser vanes,
- axial de-swirl vanes.
COMBUSTION CHAMBER
The combustion chamber is of a reverse flow annular design and is
installed inside the turbine plenum. The main parts of the combustion
chamber are:
- the inner combustion chamber shell,
- the outer combustion chamber shell.
The following components are installed on the combustion chamber:
- an igniter plug,
- 10 dual orifice fuel nozzles.
TURBINE
The turbine assembly drives the engine compressor, the load compressor
and the gear train of the Accessory Gearbox (AGB). The two-stage axial
flow turbine includes:
- a cooled first stage nozzle,
- inserted first stage rotor blades,
- an un cooled second stage stator,
- a dual alloy second stage rotor,
- an annular exhaust diffuser.
LOAD COMPRESSOR
The load compressor is of a single stage centrifugal design. It supplies
bleed air to the pneumatic system. The main components of the load
compressor are:
- the inlet guide vane assembly,
- the load compressor impeller,
- the load compressor diffuser,
- the load compressor scroll.
INLET GUIDE VANES
The Inlet Guide Vanes (IGVs) control the amount of bleed air flow andpressure from the APU load compressor. The 16 IGVs are moved
simultaneously by a gear train operated by an actuator. The IGV actuator
is operated by high-pressure fuel supplied from the Fuel Control Unit
(FCU). The IGV opening angle depends on the bleed air demand for:
- Main Engine Start (MES) system,
- Environmental Control System (ECS).
ACCESSORY GEARBOX
The gearbox transmits the shaft power to the APU accessories and to the
APU generator, which are installed on the gearbox pads. The gearbox isalso the oil reservoir for the APU lubrication system. The components
mounted on the accessory gearbox are:
- the starter motor assembly,
- the cooling air fan assembly,
- the lubrication unit with the oil pump assembly which drives the FCU,
- the AC generator.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU BASIC DESCRIPTION (3) Sep 17, 2007
Page 24
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D100
0000001
8/20/2019 ATA 49 APU
29/238
GENERAL ... ACCESSORY GEARBOX
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU BASIC DESCRIPTION (3) Sep 17, 2007
Page 25
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D100
0000001
8/20/2019 ATA 49 APU
30/238
APU IGNITION & STARTING D/O (3)
STARTER CONTROL
During starting, the electrical starter causes initial rotation of the Auxiliary
Power Unit (APU) shaft when it drives the Accessory Gearbox (AGB).When the APU speed is around 50%, the Electronic Control Box (ECB)
stops the electrical supply to the starter by opening the main start
contactor.
IGNITION CONTROL
The ignition system causes initial light-off of the fuel air mixture. The
ignition system includes an ignition box that energizes an igniter plug.
During starting, the ECB switches the ignition to ON between 7% and
60%. When the APU speed drops below 95% due to a flame-out, the
ECB starts the ignition until the APU reaches again 100% of speed.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU IGNITION & STARTING D/O (3) Sep 17, 2007
Page 26
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D300
0000001
8/20/2019 ATA 49 APU
31/238
STARTER CONTROL & IGNITION CONTROL
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU IGNITION & STARTING D/O (3) Sep 17, 2007
Page 27
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D300
0000001
8/20/2019 ATA 49 APU
32/238
APU FUEL SYSTEM D/O (3)
GENERAL
The fuel system supplies metered fuel to sustain combustion. Part of the
fuel, as muscle pressure, operates the Inlet Guide Vane (IGV) actuatorand the surge control valve actuator. This system is made of:
- Fuel Control Unit (FCU),
- fuel schedule,
- muscle pressure,
- fuel shut-off,
- flow divider and solenoid valve,
- fuel supply,
- fuel drain,
- control,
- monitoring.
FUEL CONTROL UNIT
The FCU has six functions:
- fuel filtering,
- pressure increase,
- fuel metering,
- flow meter control,
- positive fuel shut-off,
- fuel muscle pressure regulation.
The FCU is made of a LP inlet fuel filter, a High Pressure (HP) fuel
pump, a pump relief valve, a HP fuel filter, an actuator pressure regulator
for hydraulic fuel operation, a torque-motor metering valve, a resistive
temperature device, a delta pressure regulator, a flow-meter pressurizing
valve, a fuel-shutoff solenoid valve.
FUEL SCHEDULE
The Electronic Control Box (ECB) controls the fuel-metering valve
through a torque motor.
The ECB:
- schedules fuel flow during start sequence, on-speed operation and
shutdown sequence,
- refers to information on the flowmeter pressurizing valve to correct fuelflow and in relation to the fuel temperature (resistive-temperature device
signal),
- modulates the on-speed fuel schedule to agree with the aircraft demand
for bleed air and electrical power.
MUSCLE PRESSURE
Additionally fuel muscle pressure 250 psig operates the surge control
valve actuator for air release to the exhaust and the load-compressor IGV
actuator. Servo fuel return goes back to the pump inlet.
FUEL SHUT-OFF
The ECB controls the fuel 3-way solenoid valve for positive fuel shut-off.
The valve is controlled open during the start sequence and closed during
the stop sequence. Fuel goes back to the pump inlet.
FLOW DIVIDER AND SOLENOID VALVE
The flow divider supplies fuel in sequence to the primary and secondary
manifolds. It has a usually open fuel solenoid and a check valve. During
cold start or high altitude operation, the ECB energizes the solenoid valve
to close during the first 30% speed of the Auxiliary Power Unit (APU)and all fuel flow is pushed through the primary nozzles for better engine
acceleration.
FUEL SUPPLY
Two fuel manifolds and 10 dual fuel-nozzles supply fuel. Each fuel-nozzle
has a primary and a secondary fuel orifice. When APU start is selected,
the primary fuel orifice is supplied and when the fuel pressure is more
than 125 psig the check valve in the flow divider assembly opens to
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU FUEL SYSTEM D/O (3) Sep 17, 2007
Page 28
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D400
0000001
8/20/2019 ATA 49 APU
33/238
supply the secondary fuel orifice. During on-speed operation, the two
orifices are supplied.
FUEL DRAIN
Drain lines are connected to the FCU seal drain, IGV actuator and surgecontrol valve are routed to one single drain connection, on the APU drain
bracket (FWD R/H side of APU).
CONTROL
The ECB controls the fuel system with several parameters. During
on-speed operation, the ECB uses APU speed, Exhaust Gas Temperature
(EGT) and aircraft demand signals. During start, it uses speed, EGT, air
inlet pressure and temperature sensors (P2 and T2). The ECB operates
the fuel metering valve, the flow divider solenoid valve and fuel shut-off
3-way solenoid valve.
MONITORING
Fuel filter replacement is recommended every 8500 Flight Hours.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU FUEL SYSTEM D/O (3) Sep 17, 2007
Page 29
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D400
0000001
8/20/2019 ATA 49 APU
34/238
GENERAL ... MONITORING
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU FUEL SYSTEM D/O (3) Sep 17, 2007
Page 30
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D400
0000001
8/20/2019 ATA 49 APU
35/238
This Page Intentionally Left Blank
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU FUEL SYSTEM D/O (3) Sep 17, 2007
Page 31
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D400
0000001
8/20/2019 ATA 49 APU
36/238
APU OIL SYSTEM D/O (3)
GENERAL
The oil system of the Auxiliary Power Unit (APU) lubricates and
decreases the temperature of the power section, load compressor, gearboxand AC generator.
This system is made of:
- storage,
- supply,
- scavenge,
- venting,
- control,
- protection,
- monitoring.
STORAGE
The sump of the APU Accessory Gearbox (AGB) is the oil reservoir.
The AGB sump contains 6.26 l (1.65 US gal) of oil. The oil reservoir can
be filled by gravity or by pressure.
The AGB has:
- an oil fill cap for gravity filling,
- optional pressure oil servicing with a pressure fill and overfill port,
- an oil-level sight glass with FULL and ADD marks,
- a magnetic chip detector and oil drain plug installed at the lowest point
of the AGB,
- an oil heater.
SUPPLY
A three-element gerotor pressure pump pulls the oil from the sump. A
pressure-regulating valve and ultimate-relief valve assembly keeps a
constant lube supply pressure for oil supply to the engine and generator
and prevents over-pressurization of the lube system. Pressure-regulated
oil goes through a cooler and a disposable filter. The bypass valve opens
at an oil temperature below 60°C (140 °F) or when there is a differential
pressure between 55 - 60 psi around the oil cooler. The oil is then sent
to the cooling fan splines, the APU spline shaft, the APU supporting
bearings rear and front, the gearbox pinions and the electrical AC
generator.
SCAVENGE
A three-element gerotor scavenge pump and a filter sends oil from the
electrical generator to the sump. The oil from the bearing cavity of the
APU turbine goes back to the sump through a single-element gerotor
scavenge pump. Oil from the gearbox pinions and the APU front bearing
is scavenged by gravity.
VENTING
The oil from the generator is sent against the gearbox wall; this removes
the air, that is mixed with the oil. An air/oil separator removes the oil
particles from the gearbox air. This oil-free air is released in the APU
exhaust.
CONTROL
The Electronic Control Box (ECB) only controls the de-oiling valve in
the oil system. The de-oiling solenoid valve is electrically opened during
APU start to make sure of cold start conditions and to decrease the load
on the pressure pump. The solenoid valve is open during start-up to 60%RPM when:
- the oil sump temperature is below -6.7°C (+20°F),
- or the A/C altitude is above 20,000 ft,
- or the APU fuel temperature is below -12.2°C (+10°F).
The valve is energized open during every APU shutdown between 50%
and 7% speed.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU OIL SYSTEM D/O (3) Sep 17, 2007
Page 32
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D500
0000001
8/20/2019 ATA 49 APU
37/238
PROTECTION
The ECB gives protection to the APU if there is an oil system malfunction.
The ECB monitors oil pressure and oil temperature. If one of the oil
parameters is out of limit, the ECB starts an automatic APU shutdown
without time delay:- gearbox high oil temp threshold: 162.78°C (325°F),
- oil LP: 33 psi.
The ECB also stops the APU if a delta pressure switch at the scavenge
filter or at the lubrication filter shows impending filter clogging.
MONITORING
The oil system is monitored to increase the APU life. The oil sump is
installed with a low-level switch to show maintenance information in the
cockpit. When the level is at the "ADD" mark 4.60 l (1.22 US gal), the
APU can continue to operate for 10 hours maximun. This changes withthe different operating attitudes of the A/C in flight. A magnetic drain
plug, put fully in the APU oil, lets the oil drain from the sump and attracts
ferrous metal particles.
OIL HEATER
The control of the oil heater is independent of the ECB. When the oil
temperature is below 16 °C (61 °F) and the APU master switch is released
out, the heater is supplied with 115VAC.
The oil heater is switched off when the oil temperature increases above
49°C (120 °F) or the master switch is selected ON.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU OIL SYSTEM D/O (3) Sep 17, 2007
Page 33
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D500
0000001
8/20/2019 ATA 49 APU
38/238
GENERAL ... OIL HEATER
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU OIL SYSTEM D/O (3) Sep 17, 2007
Page 34
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D500
0000001
8/20/2019 ATA 49 APU
39/238
This Page Intentionally Left Blank
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU OIL SYSTEM D/O (3) Sep 17, 2007
Page 35
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D5000000001
8/20/2019 ATA 49 APU
40/238
APU AIR SYSTEM D/O (3)
GENERAL
The Auxiliary Power Unit (APU) load compressor supplies the APU
bleed air. The quantity changes with the different bleed air demands of the pneumatic system. This system is made up of:
- bleed supply,
- bleed control,
- surge protection,
- oil cooling,
- compartment cooling,
- oil vent,
- control,
- monitoring.
BLEED SUPPLY
Bleed air supply to the A/C pneumatic system is controlled by a load
control valve. The pneumatically-actuated CLOSE/OPEN butterfly valve,
which allows or stops the bleed airflow from the APU to the A/C users,
is controlled by the Electronic Control Box (ECB) and opens when the
APU BLEED P/BSW is set to the ON position.
BLEED CONTROL
The amount of air required by the pneumatic system and delivered by
the APU load compressor is controlled by the load compressor Inlet GuideVanes (IGVs). The IGVs are moved by a fuel-powered actuator.
SURGE PROTECTION
Load compressor surge protection is ensured by a surge control valve,
which discharges the excess of air in the exhaust. The surge control valve
is hydraulically operated for accurate and fast operation. The hydraulic
fluid is high pressure fuel from the Fuel Control Unit (FCU) 250 to 300
psig.
OIL COOLING
A gearbox-driven fan draws air from the inlet plenum and forces it to
pass through the oil cooler. After leaving the oil cooler, the air isdischarged overboard.
COMPARTMENT COOLING
Air supplied by the fan, driven by one of the gears of the gearbox, is also
used for APU compartment cooling. Cooling air flows through the outlets
located on the cooling fan outlet duct. Natural convection ventilates the
APU compartment through a vent grill in the upper left area of the
compartment when the APU is not in operation.
OIL VENTThe gearbox is vented to the APU exhaust. The air is bled after an air/oil
separator action.
CONTROL
The ECB controls the air system using several parameters from the
following components installed on the APU:
- APU inlet pressure (P2) and temperature (T2) sensors,
- load compressor discharge pressure sensor (PT) and differential pressure
sensor (DP),
- command and feedback signals from the actuators and the valves (IGVactuator, Load Control Valve and Surge Control Valve),
- A/C demands: Main Engine Start (MES) and Environmental Control
System (ECS).
MONITORING
To help maintenance and troubleshooting, the load control valve and the
surge control valve are equipped with visual position indicators.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU AIR SYSTEM D/O (3) Sep 17, 2007
Page 36
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D6000000001
8/20/2019 ATA 49 APU
41/238
The ECB receives feed back signals about the position of the IGVs, the
load control valve and the surge control valve.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU AIR SYSTEM D/O (3) Sep 17, 2007
Page 37
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D6000000001
8/20/2019 ATA 49 APU
42/238
GENERAL ... MONITORING
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU AIR SYSTEM D/O (3) Sep 17, 2007
Page 38
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D6000000001
8/20/2019 ATA 49 APU
43/238
This Page Intentionally Left Blank
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU AIR SYSTEM D/O (3) Sep 17, 2007
Page 39
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D6000000001
8/20/2019 ATA 49 APU
44/238
APU SYSTEM MANAGEMENT D/O (3)
APU START SEQUENCE
Auxiliary Power Unit (APU) normal operation, starting and shutdown,
are initiated from the APU control panel but controlled and monitoredby the ECB.
Following conditions will be controlled and monitored:
- APU start,
- APU on-speed,
- APU normal shutdown,
- APU protective shutdown,
- APU emergency shutdown.
When the MASTER SWitch P/B is set to ON:
- the ON light comes on,
- the Electronic Control Box (ECB) is energized,
- the ECB starts the power-up test,
- the ECB exchanges data with the Data Memory Module,
- the APU LP valve opens,
- the APU fuel pump is energized if fuel system pressure is low,
- the APU air intake flap opens.
- the ECAM APU page comes into view.
When the START P/B is set to ON:
- the ON legend comes on,
- the ECB energizes the back-up start contactor and the start contactor
when these conditions are present: air intake flap open, power-up test
complete, data exchange between data memory module and ECBcomplete,
- the contactors energize the starter motor and causes the APU main shaft
to start to turn,
- the igniter is energized at 7%,
- the de-oil valve opens with the oil/fuel temperature and altitude.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 40
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D7000000001
8/20/2019 ATA 49 APU
45/238
APU START SEQUENCE
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 41
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D7000000001
8/20/2019 ATA 49 APU
46/238
APU START SEQUENCE
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 42
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D7000000001
8/20/2019 ATA 49 APU
47/238
This Page Intentionally Left Blank
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 43
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D7000000001
8/20/2019 ATA 49 APU
48/238
APU SYSTEM MANAGEMENT D/O (3)
APU ACCELERATION SEQUENCE
APU AT 7% RPM
At 7% speed:- the ECB opens the fuel solenoid valve and combustion occurs,
- the Inlet Guide Vanes (IGVs) close,
- Ignition ON.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 44
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D7000000001
8/20/2019 ATA 49 APU
49/238
APU ACCELERATION SEQUENCE - APU AT 7% RPM
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 45
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D7000000001
8/20/2019 ATA 49 APU
50/238
APU SYSTEM MANAGEMENT D/O (3)
APU ACCELERATION SEQUENCE (continued)
APU AT 50% RPM
At 50% speed:- the ECB de-energizes the start contactor, above 20,000 ft at 58%,
and causes the starter motor to stop and continues to increase the speed
of the APU automatically,
- the ECB de-energizes the back-up start contactor.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 46
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D7000000001
8/20/2019 ATA 49 APU
51/238
APU ACCELERATION SEQUENCE - APU AT 50% RPM
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 47
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D70
00000001
8/20/2019 ATA 49 APU
52/238
APU SYSTEM MANAGEMENT D/O (3)
APU ACCELERATION SEQUENCE (continued)
APU AT 60% RPM
At 60% speed:- the ECB de-energizes the ignition unit,
- the ECB de-energizes the de-oil solenoid, if it is open.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 48
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D70
00000001
8/20/2019 ATA 49 APU
53/238
APU ACCELERATION SEQUENCE - APU AT 60% RPM
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 49
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D70
00000001
8/20/2019 ATA 49 APU
54/238
APU SYSTEM MANAGEMENT D/O (3)
APU ACCELERATION SEQUENCE (continued)
APU AT 95% RPM
At 95% speed:- the IGVs move to 22 degrees' open position to prevent overheating,
- the ECB controls and monitors the APU automatically,
- the ON light in the START P/BSW goes off,
- the green AVAIL legend in the START P/BSW comes on.
- the APU generator can operate and APU bleed be switched to ON.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 50
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D70
00000001
8/20/2019 ATA 49 APU
55/238
APU ACCELERATION SEQUENCE - APU AT 95% RPM
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 51
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D70
00000001
8/20/2019 ATA 49 APU
56/238
APU SYSTEM MANAGEMENT D/O (3)
APU ACCELERATION SEQUENCE (continued)
APU AT 100% RPM
At steady state speed, an on-speed governor loop controls the fuelflow to the APU. With APU bleed selected to OFF or in ECS mode
the APU speed is 99%. When in Main Engine Start (MES) mode or
always when the aircraft is in flight, the APU speed is 100%.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 52
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D70
00000001
8/20/2019 ATA 49 APU
57/238
APU ACCELERATION SEQUENCE - APU AT 100% RPM
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 53
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D70
00000001
8/20/2019 ATA 49 APU
58/238
APU SYSTEM MANAGEMENT D/O (3)
APU ON-SPEED
When the APU generator operates, the generator output parameters come
into view on the ECAM system page. When the APU bleed is switchedto ON, bleed parameters are displayed on the ECAM system page. The
ECB opens the Load Control Valve in accordance to the Bleed Monitoring
Computer (BMC) signal coming from the APU Bleed P/B.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 54
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D70
00000001
8/20/2019 ATA 49 APU
59/238
APU ON-SPEED
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 55
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D70
00000001
8/20/2019 ATA 49 APU
60/238
APU SYSTEM MANAGEMENT D/O (3)
APU NORMAL SHUTDOWN
When the MASTER SW is OFF, the ECB closes the IGVs to the minimum
position of 15°, the load control valve closes if it is open, the surge controlvalve opens and the cool-down cycle of the APU starts.
The cool-down cycle lets the APU operate for 60 seconds at a low
stabilized temperature. It starts when the ECB receives the closed signal
from the load control valve. If the load control valve was not in the open
position, the ECB supplies a signal to simulate an overspeed condition,
which causes the fuel solenoid to close and starts the APU shutdown
immediately.
Overspeed test occurs when the cool-down cycle is complete. The ECB
supplies a signal to simulate an overspeed condition, that causes the fuel
solenoid to close, and starts the APU shutdown.
It is possible to command an APU re-start during the shutdown sequence.APU speed must be below 7% before the starter motor is re-engaged.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 56
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D70
00000001
8/20/2019 ATA 49 APU
61/238
APU NORMAL SHUTDOWN
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 57
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D70
00000001
8/20/2019 ATA 49 APU
62/238
APU SYSTEM MANAGEMENT D/O (3)
APU NORMAL SHUTDOWN (continued)
APU AT 95% RPM
At 95% speed, APU "AVAIL" lights go off.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 58
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D7000000001
8/20/2019 ATA 49 APU
63/238
APU NORMAL SHUTDOWN - APU AT 95% RPM
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 59
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D7000000001
8/20/2019 ATA 49 APU
64/238
APU SYSTEM MANAGEMENT D/O (3)
APU NORMAL SHUTDOWN (continued)
APU AT 50% RPM
At 50% speed, the de-oil solenoid valve opens to decrease drag duringthe next start.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 60
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D7000000001
8/20/2019 ATA 49 APU
65/238
APU NORMAL SHUTDOWN - APU AT 50% RPM
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 61
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D7000000001
8/20/2019 ATA 49 APU
66/238
APU SYSTEM MANAGEMENT D/O (3)
APU NORMAL SHUTDOWN (continued)
APU BELOW 7% RPM
At and below 7% speed:- the de-oil solenoid closes,
- the APU fuel LP valve closes,
- the data memory module is updated,
- the air intake flap closes,
- the ECB de-energizes itself.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 62
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D7000000001
8/20/2019 ATA 49 APU
67/238
APU NORMAL SHUTDOWN - APU BELOW 7% RPM
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 63
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D7000000001
8/20/2019 ATA 49 APU
68/238
APU SYSTEM MANAGEMENT D/O (3)
APU PROTECTIVE SHUTDOWN
When the ECB is energized, it controls the APU starting and operating
phases. If an abnormal parameter is found, it starts an immediate shutdownwithout time delay, even if the APU bleed air is in use.
The ECB protective shutdown parameters are:
- overspeed,
- ECB failure,
- underspeed,
- overtemperature,
- loss of speed,
- sensor failure: thermocouples, low oil level and Low Oil Pressure (LOP)
switch failure,
- no flame,
- flap not open,- High Oil Temperature (HOT),
- LOP
- no speed,
- inlet overheat,
- no acceleration,
- clogged oil filter,
- main power stop.
APU EMERGENCY SHUTDOWN
The ECB starts an emergency shutdown when the APU FIRE P/B, in thecockpit, is released out or when the APU SHUT OFF P/B, on the external
power receptacle panel, is pushed. The ECB starts an automatic
emergency shutdown when an APU fire is found on ground. The APU
stops immediately without time delay, even if the APU bleed air system
is in use.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 64
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D7000000001
8/20/2019 ATA 49 APU
69/238
APU PROTECTIVE SHUTDOWN & APU EMERGENCY SHUTDOWN
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 65
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D7000000001
8/20/2019 ATA 49 APU
70/238
APU WARNINGS (3)
EMERGENCY SHUT DOWN
If an EMERgency SHUT DOWN occurs, the single chime sounds, the
MASTER CAUTion and the MASTER SWitch FAULT lights come on.
The failure is shown amber on the EWD associated to indications on the
Auxiliary Power Unit (APU) ECAM page. An EMER SHUT DOWN
occurs when:
- the APU shut-off P/B is pressed on the external power control panel,
- the APU FIRE P/B is released out on the overhead panel,
- the automatic fire extinguishing logic is triggered on ground.
AUTOMATIC SHUT DOWN
If an AUTOmatic SHUT DOWN occurs, the single chime sounds, the
MASTER CAUTion and the MASTER Switch FAULT lights come on.
The failure is shown amber on the EWD associated to indications on the
APU ECAM page. An AUTO SHUT DOWN occurs in case of:
- overspeed,
- overtemperature,
- Low Oil Pressure (LOP),
- High Oil Temperature (HOT),
- no flame,
- no acceleration,
- low acceleration rate,
- deceleration during start sequence,
- surge/reverse flow,- generator high oil temperature,
- loss of DC power,
- underspeed,
- loss off speed,
- sensor failure,
- air intake not open,
- ECB failure.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU WARNINGS (3) Sep 17, 2007
Page 66
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49W1
000000001
8/20/2019 ATA 49 APU
71/238
EMERGENCY SHUT DOWN & AUTOMATIC SHUT DOWN
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU WARNINGS (3) Sep 17, 2007
Page 67
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49W1
000000001
8/20/2019 ATA 49 APU
72/238
ECB INTERFACES (3)
POWER SUPPLY
One of the A/C batteries at the minimum and the A/C DC network,
electrically supply the Electronic Control Box (ECB), through the MAIN
control relay of the Auxiliary Power Unit (APU).
MASTER SWITCH P/B
The APU MASTER SWITCH sends a discrete supply or stop signal to
the ECB. The ECB sends a discrete signal to the FAULT light, when an
automatic shutdown occurs or if there is an emergency shutdown.
AIR INTAKE FLAP
The ECB receives an air intake flap open or closed position signal and
sends a power output to open or close the air intake flap.
START P/B
A discrete input signal from the START P/B starts the starting sequences.
The ECB sends a discrete signal to the ON light during the APU start
sequence. A discrete output signal to the A/C energizes the AVAIL light
in the START P/B when the APU speed is above 95%.
BACK-UP AND MAIN START CONTACTORS
The ECB receives a discrete input from the main start contactor and sends
discrete outputs to the back-up and main start contactors.
EMERGENCY STOP
A discrete input signal from the A/C starts the APU emergency shutdown
logic after the ECB receives this signal.
LGCIU 1
The ECB receives the aircraft on ground discrete input signal from
Landing Gear Control and Interface Unit (LGCIU) 1.
APU FUEL FEED SYSTEM
The ECB receives a discrete signal from the APU low fuel pressure
switch. It sends a discrete signal to the APU fuel LP shut-off valve.
EIU
During engine starts, the ECB receives a Main Engine Start (MES) signal
from Engine Interface Unit (EIU) 1 or 2. This signal causes the ECB to
set the Inlet Guide Vanes (IGVs) to the fully open position if APU bleed
has been selected to ON.
BMC
When the APU BLEED P/B is set to ON, Bleed Monitoring Computer
(BMC) 1 or 2 sends a discrete input to the ECB. This controls the APU
load control valve to open. The BMCs receive a closed-position signal
from the APU load control valve to monitor the pneumatic system and
to show ECAM indications.
TSO/JAR
The ECB receives a discrete input from the TSO/JARconfiguration-programming pin. This open or ground signal finds if the
ECB obeys the Technical Standard Order (TSO) or the Joint Aviation
Requirements (JAR). Concerning the JAR, all System Display (S/D)
circuits are available in flight. This configuration is the standard
configuration. For TSO, only emergency, overspeed and loss of speed
shutdowns, are available in flight.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
ECB INTERFACES (3) Sep 17, 2007
Page 68
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49F1000000004
8/20/2019 ATA 49 APU
73/238
ENVIRONMENTAL CONTROL SYSTEM (ECS)
The ECB receives, via an ARINC 429 bus, an input from the Air
Conditioning System Controller 1 and 2 (ACSC) to control the IGVs
position according to the demand. The ECB sends a discrete output to
the ACSC 1 and 2 to signal that the APU bleed valve is en deliveryposition.
A320/A321 IDENTIFICATION
The ECB receives a discrete input from the A/C signature PIN
PROGramming. This identification pin lets the ECB identify A321
applications for functional differences from those of an A320.
SDAC
The ECB sends to System Data Acquisition Concentrators (SDACs) 1
and 2, through ARINC 429 Data buses, the indications to show on theECAM APU page and shutdown information to start the related warnings.
CFDS
The ECB is a BITE system type-1 computer and connects to the
Centralized Fault Display System (CFDS) through ARINC 429 data
buses.
DMU PART
The Data Management Unit (DMU) part of the Flight Data Interface and
Management Unit (FDIMU) partially keeps APU lifetime data. This
information lets you monitor the engine conditions.
DATA MEMORY MODULE
A data memory module installed on the APU inlet plenum keeps and
interchanges many parameters with the ECB:
- APU serial number,
- APU operating hours and starts,
- APU accumulated hot time,
- APU accumulated shutdowns, etc.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
ECB INTERFACES (3) Sep 17, 2007
Page 69
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49F1000000004
8/20/2019 ATA 49 APU
74/238
POWER SUPPLY ... DATA MEMORY MODULE
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
ECB INTERFACES (3) Sep 17, 2007
Page 70
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49F1000000004
Si l Ai l TECHNICAL TRAINING MANUAL
8/20/2019 ATA 49 APU
75/238
This Page Intentionally Left Blank
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
ECB INTERFACES (3) Sep 17, 2007
Page 71
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49F1000000004
Si l Ai l TECHNICAL TRAINING MANUAL
8/20/2019 ATA 49 APU
76/238
APU DRAIN SYSTEM PRESENTATION (2)
FUEL/OIL PUMP DRAIN
The fuel and oil pump seal drain line is routed via a collector line to the
drain tank. This line drains fuel or oil leaks.
DRAIN PORT AIR CHECK VALVE
An air check valve, mounted on the Fuel Control Unit (FCU) drain line,
prevents air ingestion in the FCU.
GEARBOX VENT
The accessory gearbox is vented to the Auxiliary Power Unit (APU)
exhaust through a vent line. This line vents gearbox air to the APU
exhaust.
IGV ACTUATOR DRAIN
The Inlet Guide Vane (IGV) actuator drain line is routed via a collector
line to the drain tank. This line drains only fuel leaks.
FLOW DIVIDER DRAIN
The fuel flow divider and drain valve drain line is routed via a collector
line to the drain tank. This drain line collects fuel purged from the nozzles
and the manifolds at APU shutdown.
TURBINE PLENUM DRAIN
The turbine plenum drain line is routed alone to the drain mast. This drain
line collects unburned fuel after a failed start attempt.
HEAT SHIELD DRAIN
The heat shield drain line is routed to the drain mast. This drain line
collects fuel, water or air leaks.
EXHAUST COUPLING DRAIN
The exhaust coupling drain line is routed to the drain mast. This drain
line collects fuel, water or air leaks.
DRAIN TANK
For venting and evacuation, the drain tank is connected to the drain mast.
Airflow across the drain mast creates a vacuum in the drain line. The
suction effect produced at 200 kt, is sufficient to remove the contents of
the drain tank. A vent line ventilates the drain tank and drain lines. The
APU drain lines are connected to the right access door drain lines through
spring adapter kiss seals. The drain mast drains any fluid leakage from
the APU through four holes.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU DRAIN SYSTEM PRESENTATION (2) Sep 17, 2007
Page 72
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49P2000000002
Si l Ai l TECHNICAL TRAINING MANUAL
8/20/2019 ATA 49 APU
77/238
FUEL/OIL PUMP DRAIN ... DRAIN TANK
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU DRAIN SYSTEM PRESENTATION (2) Sep 17, 2007
Page 73
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49P2000000002
Si l Ai l TECHNICAL TRAINING MANUAL
8/20/2019 ATA 49 APU
78/238
APU BASIC DESCRIPTION (3)
GENERAL
The Auxiliary Power Unit (APU) is of a modular design. The three APU
modules are:
- the power section,
- the load compressor,
- the Accessory Gearbox (AGB).
POWER SECTION
The compressor is of a single stage centrifugal compressor design. The
main components of the compressor are:
- the inlet plenum,
- the impeller and the diffuser,
- the Inlet Guide Vane (IGV) assembly,
- the compressor hub containment.
COMBUSTION CHAMBER
The combustion chamber is of a reverse flow annular design and is
installed inside the turbine plenum. The main parts of the combustion
chamber are:
- the inner combustion chamber shell,
- the outer combustion chamber shell.
The following components are installed on the combustion chamber:
- the igniter plug,
- the six fuel nozzles.
TURBINE
The turbine assembly drives the compressor, the load compressor and
the gear train of the AGB. The single stage radial inflow turbine includes:
- a cooled nozzle guide vane,
- a rotor,
- a diffuser exhaust pipe including a diffuser nozzle and seven radial
vanes.
LOAD COMPRESSOR
The load compressor is of a single stage centrifugal design. The main
components of the load compressor are:
- the inlet guide vane assembly,
- the load compressor impeller,
- the load compressor diffuser,
- the load compressor scroll.
INLET GUIDE VANES
The IGV assembly controls the amount of air flowing through the APU
load compressor. The 14 IGV' are moved simultaneously by a gear train
operated by a fuel driven actuator actuator.
ACCESSORY GEARBOX
The gearbox transmits the shaft power to the APU accessories and to the
APU generator, which are installed on the gearbox pads. The gearbox is
also the oil reservoir for the APU lubrication system. The components
mounted on the accessory gearbox are:
- the starter motor assembly,
- the cooling air fan assembly,
- the lubrication unit,
- the Fuel Control Unit (FCU),
- the AC generator.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU BASIC DESCRIPTION (3) Sep 17, 2007
Page 74
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D1
000000002
Single Aisle TECHNICAL TRAINING MANUAL
8/20/2019 ATA 49 APU
79/238
GENERAL ... ACCESSORY GEARBOX
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU BASIC DESCRIPTION (3) Sep 17, 2007
Page 75
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D1
000000002
Single Aisle TECHNICAL TRAINING MANUAL
8/20/2019 ATA 49 APU
80/238
APU IGNITION & STARTING D/O (3)
STARTER CONTROL
The starting system rotates and accelerates the Auxiliary Power Unit
(APU) rotor through a clutch and gearbox. When the APU speed is about
50%, the start logic of the Electronic Control Box (ECB) cuts off the
supply to the start contactor, which switches off the starter motor. The
timed acceleration loop of the ECB causes the APU to accelerate to
governed speed.
APU START CONDITIONS
An electric DC motor starts the APU. On ground operation conditions,
the APU is started by the aircraft batteries or aircraft batteries in
combination with Transfomer Rectifier Units (TRUs). A start in flight
is possible up to an altitude of 11900 m (39000 ft.) with the use of
TRUs. A start in flight is possible up to an altitude of 7630 m (25000ft.) with the use of the aircraft batteries only.
For successful APU starting on ground or in flight, both batteries PB
must be switched to the AUTO position according to Airbus
procedures.
IGNITION CONTROL
The ignition system provides initial light-off of the fuel air mixture in
the combustion chamber. The ignition system includes:
- an ignition unit, which produces high voltage electrical energy,
- an ignition lead which delivers electrical energy to an igniter plugscrewed into the combustion chamber.
During starting, the ECB switches on the ignition between 7% and 95%.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU IGNITION & STARTING D/O (3) Sep 17, 2007
Page 76
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D3
000000002
Single Aisle TECHNICAL TRAINING MANUAL
8/20/2019 ATA 49 APU
81/238
STARTER CONTROL & IGNITION CONTROL
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU IGNITION & STARTING D/O (3) Sep 17, 2007
Page 77
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D3
000000002
Single Aisle TECHNICAL TRAINING MANUAL
8/20/2019 ATA 49 APU
82/238
APU FUEL SYSTEM D/O (3)
GENERAL
The Auxiliary Power Unit (APU) fuel system operates fully automatically.
The APU fuel system includes:
- a Fuel Control Unit (FCU) which schedules the fuel flow,
- a flow divider and drain valve assembly which directs the fuel to the
nozzles.
FUEL CONTROL UNIT
The fuel flow into the fuel control unit passes through the inlet fuel filter
to the High-Pressure (HP) fuel pump, and then it goes through the HP
filter to:
- the Inlet Guide Vane (IGV) actuator to position the IGVs,
- the Torque Motor (TM) metering valve for flow control,
- the differential pressure regulator.
The metered fuel goes through the pressurizing valve to the fuel shut-off
solenoid valve. The fuel solenoid valve is normally closed. It is electrically
controlled to be opened by the Electronic Control Box (ECB) when the
speed is above 7% rpm. When the fuel solenoid valve is open, the
pressurizing valve ensures that the appropriate working fuel pressures
are available to the system. The HP fuel pump will produce more fuel
flow than required to support combustion under any given rpm. A
differential pressure-regulating valve bypasses the excess fuel back to
the filter inlet.
FLOW DIVIDER AND DRAIN VALVE ASSEMBLY
The purpose of the flow divider is to direct fuel to the primary and
secondary manifolds. Both manifolds supply duplex fuel nozzles. From
7% rpm, the primary nozzles are supplied with fuel above 7.5 psi.
Secondary nozzles are supplied above 150 psi during acceleration and
running phases.
TIME ACCELERATION RATE SCHEDULE
The time acceleration rate schedule controls the fuel in order to cause
the APU speed to increase at a constant rate without overtemperature. It
controls the fuel TM of the FCU. The ECB protective circuits are set to
shut down the APU if a start is initiated and:
- speed is less than 7% for more than 30 seconds,
- speed is less than 20% for more than 50 seconds,
- speed is less than 50% for more than 70 seconds,
- acceleration rate is below 0.2% per second with Exhaust Gas
Temperature (EGT) above 204°C,
- EGT is below 204°C with speed more than 7% for 15 seconds.
SPEED CONTROL
The ECB controls the speed by means of the fuel TM according to the
bleed air demand from the air conditioning system or for Main Engine
Start (MES). On ground, the ECB maintains the speed at 99% rpm if
APU bleed is switched off, or with bleed air demand from the air
conditioning system and ambient temperature below 25°C, 101% rpm
with bleed air demand from the air conditioning system and ambient
temperature above 30°C, or for MES. In flight, the ECB maintains speed
at 101% rpm.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU FUEL SYSTEM D/O (3) Sep 17, 2007
Page 78
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D4
000000002
Single Aisle TECHNICAL TRAINING MANUAL
8/20/2019 ATA 49 APU
83/238
GENERAL ... SPEED CONTROL
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU FUEL SYSTEM D/O (3) Sep 17, 2007
Page 79
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D4
000000002
Single Aisle TECHNICAL TRAINING MANUAL
8/20/2019 ATA 49 APU
84/238
APU OIL SYSTEM D/O (3)
GENERAL
This system is made up of:
- oil reservoir,
- oil level switch,
- gearbox pressure regulator valve
- lubrication unit (including pressure pump, scavenge pumps, Pressure
Regulating Valve (PRV))
- oil cooler,
- one lubrication filter (mounted on lubrication unit) and one scavenge
filter,
- oil temperature sensor,
- de-oil solenoid valve.
OIL RESERVOIRThe sump of the Auxiliary Power Unit (APU) accessory gearbox is the
oil reservoir. Oil is serviced through either a pressure fill port or a gravity
fill port. The accessory gearbox sump contains 5.7 l (1.5 US gal) of oil.
An APU oil heater is installed on the APU gearbox. When the APU
MaSTeR SWitch is not on, the oil heater is supplied with 115V AC. The
heater is controlled on when the temperature
8/20/2019 ATA 49 APU
85/238
SCAVENGE PUMPS
Two scavenge pumps return the oil to the accessory gearbox. One
scavenge returns the power section rear bearing oil. The other scavenge
pump returns the generator oil through a separate filter. Both pumps form
part of the lubrication module and are driven by the same shaft as the
pressure pump. Oil from the power section forward bearing, gearbox
bearings, gears and starter clutch returns by gravity.
OIL MONITORING
The ECB monitors the oil pressure and oil temperature.
The ECB will shut down the APU if:
- the Low Oil Pressure switch (LOP) senses pressure below 35 psi (2.38
bar),
- the High Oil Temperature switch (HOT) senses temperature above
152°C (305.6°F),
- the generator oil temperature is above 185°C(365°F).
DE-OIL SYSTEM
The de-oiling solenoid valve reduces the oil pressure pump load during
the APU start, especially during the cold start condition when oil has a
high viscosity. The valve is located on the upper right hand side of the
gearbox. A solenoid operates the valve position. The ECB controls the
solenoid in relation to the de-oiling solenoid logic.
The solenoid valve is open when:
- the APU speed is between 0% and 60% and the oil sump temperature
is below -6.7 C (20 F),
- the APU speed is between 95% and 7% during the APU shutdown
sequence,
- the aircraft altitude is more than 30.000 ft.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU OIL SYSTEM D/O (3) Sep 17, 2007
Page 81
Single Aisle TECHNICAL TRAINING MANUAL
U5E07351-u2ST0T0-UM49D5000000002
Single Aisle TECHNICAL TRAINING MANUAL
8/20/2019 ATA 49 APU
86/238
GENERAL ... DE-OIL SYSTEM
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU OIL SYSTEM D/O (3) Sep 17, 2007
Page 82
g
U5E07351-u2ST0T0-UM49D5000000002
Single Aisle TECHNICAL TRAINING MANUAL
8/20/2019 ATA 49 APU
87/238
This Page Intentionally Left Blank
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU OIL SYSTEM D/O (3) Sep 17, 2007
Page 83
g
U5E07351-u2ST0T0-UM49D5000000002
Single Aisle TECHNICAL TRAINING MANUAL
8/20/2019 ATA 49 APU
88/238
APU AIR SYSTEM D/O (3)
GENERAL
The Auxiliary Power Unit (APU) load compressor supplies the APU
bleed air. The quantity of the supplied bleed air changes with the different
bleed air demand from the Environmental Control System (ECS) or if
the main engines are started. This system is made up of:
- Inlet Guide Vanes (IGVs),
- the Electronic Control Box (ECB) which provides information of ECS
load, Main Engine Start (MES) load, Exhaust Gas Temperature (EGT),
generator load,
- bleed (load) valve,
- surge control valve,
- cooling.
INLET GUIDE VANES
Depending on the load demand, the ECB adjusts the speed of the APU
and positions the IGVs to modulate the airflow available from the load
compressor. The IGVs are driven by an actuator operated by fuel pressure,
and controlled by a Torque Motor (TM) signaled from the ECB. During
the start sequence, the IGVs are fully closed below 50% rpm, 10° open
between 50% and 75% rpm and 22° open above 75% rpm. The minimum
open or idle position of the IGVs, when the APU is running, is 22°. The
maximum open position of the IGVs is 88°. Above 23000 ft, the IGVs
assume the idle position and below 21000 ft they will open on demand.
ECS LOAD
In response to the ECS signal coming from the zone controller, the IGV
position may not exceed limits set in the ECB. APU speed is 99% rpm
if ambient temperature is or falls below 25°C (+77°F) or 101% rpm if
temperature is or rises above 30°C (86°F). The IGVs modulate within
limits. The ECS limits are: ECS MIN, ECS COLD, ECS NORMAL, ECS
HOT, memorized by the Erasable Programmable Read Only Memory
(EPROM) which is part of the ECB.
MES LOAD
In response to the MES signal coming from the Engine Interface Units
(EIUs), the ECB sets the IGVs to the fully open position. The IGVs are
fully opened. The APU speed is controlled to 101%. The MES load is
limited by an MES limit set in the ECB and memorized by the EPROM.
EGT
The bleed airflow is reduced as a function of the compressor inlet
temperature and the EGT. The EGT cannot exceed a limit set in the ECB.
T2 is the Load Compressor Inlet Temperature (LCIT). T5 is the EGT.
The EGT limit is set in the ECB and memorized by the EPROM.
NOTE: The APU bleed air system is used for MES and ECS.
GENERATOR LOAD
If the APU load is high and EGT increases to its limit, the ECB reduces
the bleed air load by controlling the IGVs to close. If a generator shock
load occurs, speed decreasing by more than 10% rpm per second, the
IGVs are closed for 3 seconds.
BLEED VALVE
The bleed air delivered by the load compressor is ducted to the aircraft
pneumatic system via the bleed (load) valve. The bleed valve is
electrically controlled and pneumatically operated. Each Bleed Monitoring
Computer (BMC) sends an opening signal to the ECB, which energizes
the bleed load valve solenoid only if the APU speed is greater than 95%
and no shutdown is initiated.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU AIR SYSTEM D/O (3) Sep 17, 2007
Page 84
g
U5E07351-u2ST0T0-UM49D6000000002
Single Aisle TECHNICAL TRAINING MANUAL
8/20/2019 ATA 49 APU
89/238
SURGE CONTROL VALVE
The air delivered by the load compressor may be much more than the air
needed by the pneumatic system. The surge control valve discharges the
excess air into the APU exhaust. The ECB controls the surge valve via
a torque motor. To avoid compressor surge, a calculated airflow is
determined according to the IGV positions. The ECB compares the
compressor airflow rate, measured by using a total pressure transducer
at the load compressor outlet and a Differential Pressure (DELTA P)
transducer, with the calculated airflow. The airflow difference repositions
the surge valve. When the bleed load valve is open, the surge control
valve tends to close. During MES, the surge valve modulates to give a
constant bleed air pressure.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU AIR SYSTEM D/O (3) Sep 17, 2007
Page 85
U5E07351-u2ST0T0-UM49D6000000002
Single Aisle TECHNICAL TRAINING MANUAL
8/20/2019 ATA 49 APU
90/238
GENERAL ... SURGE CONTROL VALVE
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU AIR SYSTEM D/O (3) Sep 17, 2007
Page 86
U5E07351-u2ST0T0-UM49D6000000002
Single Aisle TECHNICAL TRAINING MANUAL
8/20/2019 ATA 49 APU
91/238
This Page Intentionally Left Blank
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU AIR SYSTEM D/O (3) Sep 17, 2007
Page 87
U5E07351-u2ST0T0-UM49D6000000002
Single Aisle TECHNICAL TRAINING MANUAL
8/20/2019 ATA 49 APU
92/238
APU AIR SYSTEM D/O (3)
COOLING
A gearbox driven cooling fan draws the air from the inlet plenum and
forces most of it through the oil cooler. The remaining air is used for
APU compartment ventilation.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU AIR SYSTEM D/O (3) Sep 17, 2007
Page 88
U5E07351-u2ST0T0-UM49D6000000002
Single Aisle TECHNICAL TRAINING MANUAL
8/20/2019 ATA 49 APU
93/238
COOLING
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU AIR SYSTEM D/O (3) Sep 17, 2007
Page 89
U5E07351-u2ST0T0-UM49D6000000002
Single Aisle TECHNICAL TRAINING MANUAL
8/20/2019 ATA 49 APU
94/238
APU SYSTEM MANAGEMENT D/O (3)
RUNNING SEQUENCE - AIR INTAKE FLAP SEQUENCE
When the APU MASTER SWITCH is set to ON, the Electronic Control
Box (ECB) is electrically supplied and initiates a power-up test. The
Auxiliary Power Unit (APU) fuel system is energized and the air intakeflap is controlled to open. The APU fuel LP valve opens and the APU
fuel pump logic is energized. The APU fuel pump will run as long as the
main engine fuel feed line pressure is lower than 23 psi (1.56 bar). The
ECB controls the opening of the air intake flap. When it is fully open, in
20 seconds, the ECB receives a flap open signal.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 90
U5E07351-u2ST0T0-UM49D7000000002
Single Aisle TECHNICAL TRAINING MANUAL
8/20/2019 ATA 49 APU
95/238
RUNNING SEQUENCE - AIR INTAKE FLAP SEQUENCE
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 91
U5E07351-u2ST0T0-UM49D7000000002
Single Aisle TECHNICAL TRAINING MANUAL
8/20/2019 ATA 49 APU
96/238
APU SYSTEM MANAGEMENT D/O (3)
RUNNING SEQUENCE - START SEQUENCE
Then, when the START P/B has been pressed, the ECB initiates the start
sequence by closing the start contactors only if the listed conditions are
met. The start contactors are closed if:- the power-up test is completed,
- the APU speed is less than 7 % rpm,
- no shutdown is initiated.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 92
U5E07351-u2ST0T0-UM49D
7000000002
Single Aisle TECHNICAL TRAINING MANUAL
8/20/2019 ATA 49 APU
97/238
RUNNING SEQUENCE - START SEQUENCE
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 93
U5E07351-u2ST0T0-UM49D
7000000002
Single Aisle TECHNICAL TRAINING MANUAL
8/20/2019 ATA 49 APU
98/238
APU SYSTEM MANAGEMENT D/O (3)
RUNNING SEQUENCE - ACCELERATION SEQUENCE
The APU spool speed is monitored by two identical speed sensors
installed on the gearbox casing. The ECB takes into account the highest
speed signal for APU control and ECAM display. N represents thepercentage of APU rpm.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 94
U5E07351-u2ST0T0-UM49D
7000000002
Single Aisle TECHNICAL TRAINING MANUAL
8/20/2019 ATA 49 APU
99/238
RUNNING SEQUENCE - ACCELERATION SEQUENCE
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 95
U5E07351-u2ST0T0-UM49D
7000000002
Single Aisle TECHNICAL TRAINING MANUAL
8/20/2019 ATA 49 APU
100/238
APU SYSTEM MANAGEMENT D/O (3)
RUNNING SEQUENCE - ACCELERATION SEQUENCE
(continued)
APU AT 7% RPM
At 7%, the ECB energizes the igniter and opens the fuel solenoid
valve on the Fuel Control Unit (FCU). The ECB also sets the correct
metered quantity of fuel for engine light-up. The metered quantity of
fuel is adjusted by the fuel Torque Motor (TM).
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 96
U5E07351-u2ST0T0-UM49D
7000000002
Single Aisle TECHNICAL TRAINING MANUAL
8/20/2019 ATA 49 APU
101/238
RUNNING SEQUENCE - ACCELERATION SEQUENCE - APU AT 7% RPM
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 97
U5E07351-u2ST0T0-UM49D
7000000002
Single Aisle TECHNICAL TRAINING MANUAL
8/20/2019 ATA 49 APU
102/238
APU SYSTEM MANAGEMENT D/O (3)
RUNNING SEQUENCE - ACCELERATION SEQUENCE
(continued)
APU AT 50% RPM
The light-up phase is confirmed by the increase in Exhaust Gas
Temperature (EGT). This temperature is monitored by two sensors,
which send a signal to the ECB. The ECB takes into account the
highest temperature value for APU control and EGT ECAM display.
The EGT increases as the APU accelerates, with starter motor
assistance to 50% rpm where the ECB cuts off the electrical supply
to the start contactors. At 50% rpm, the Inlet Guide Vanes (IGVs)
move to 10° open to avoid compressor surge. Above 50% rpm, the
APU continues to accelerate under its own power to governed speed.
T1+T2 (CFM 56 / ME) (Lvl 2&3)
49 - APU
APU SYSTEM MANAGEMENT D/O (3) Sep 17, 2007
Page 98
U5E07351-u2ST0T0-