Post on 15-Dec-2020
Version date: Apr. 03, 2013 Version 1.5.1 Page 1 of 59
Approved Components List Mechanical Components
For the Manufacture Of Engine, Transmission, Chassis, Foundry
Of the Volkswagen Group
"Technology-Specific Part"
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 2 of 59
Change history
Version Date Type of change Chapter
0.0 Jan 01, 2007 First edition
0.1 Aug. 01, 2008
• Site of Hanover foundry added • Contact for AUDI and VW Motor Polska was changed • Gear pump BG 13 added • Information about filling coupling added • New accumulator series: 4X; preload pressure 2 bar; • Accumulator size 2.5 l added; types corrected • Spool variants for directional valve size 6 added • Spool variants for directional valve size 10 added • Explanation of code letters added
Cover page 2 4.1.1.1.1 4.1.2.1 4.1.9 4.2.1.1.1 4.2.1.1.2 4.3.1
1.2 Aug. 03, 2009
• Renaming of release list: "Aggregatefertigungen Fahrwerk, Getriebe, Motor" (Unit manufacturing of chassis, gear, motor"
• Enlargement Wolfsburg site • Addition/change of tel. no. of M. Bödecker and M. Hierling
New contact in Czech Republic and Poland • Reference to chapter 6 added • New filter product range • Correction of text • New filter product range • Change in electr. plug-in connection on directional valves of
"…K33L“ in "…K72L“ • Update of series, type key and data sheet number • Change in electr. plug-in connection on directional valves of
"…K33L“ in "…K72L“ • Update of series, type key and data sheet number • Change in electr. plug-in connection on directional valves of
"…K33L“ in "…K72L“ • Addition of component release for use with HFC fluids
Cover page Cover page 2 3 4.1.4 4.1.2.1 4.1.6 4.1.3 4.1.9.3 4.2.1 4.2.2.1.3.1 4.2.3.1.2.3 6
1.3 July 01, 2010
Layout revised and table of contents corrected • Filling coupling and filling circuit added, material no. added • Change of air filter • Text added • Addition of duplex switch filter
all 4.1.2.1 4.1.3; 6.1.3 4.1.5 4.1.5.3
1.4 July 01, 2012
• Complete revision (layout, update of component series, technical and editorial corrections,
Significant changes: • Solenoids for directional valves with reduced electric power
consumption obligatory • El. motors according to "IE2" up to 5.5 kW with plug-in
connection • "NBR" sealing material preferred • Filter component series updated, new clogging indicator • Diaphragm type accumulator for clamping applications added
all
1.5 Jan. 01, 2013 • Material number corrected 3.2.1.1.1.1
1.5.1 April 03, 2013 • Change of designation for double check valves • Change of designation for single check valves
3.2.2.1.3.1 5.2.3.1.3.2
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 3 of 59
Table of contents
Change history ................................................................................................................................. 2
1 Contacts ............................................................................................................................ 6
2 Notes ................................................................................................................................. 7
3 Overview ........................................................................................................................... 8 3.1 Pump station with tank and accessories .......................................................................... 8 3.1.1 Pumps ............................................................................................................................... 8 3.1.1.1 Fixed displacement pumps (gear pumps) ........................................................................ 8 3.1.1.2 Variable displacement pumps ........................................................................................... 8 3.1.1.2.1 Vane pumps ..................................................................................................................... 8 3.1.1.2.2 Axial piston pumps ........................................................................................................... 8 3.1.2 Tanks and small power units ............................................................................................ 9 3.1.2.1 Tanks 100 to 1000 l (DIN-24339, type BN, cover type A) ................................................ 9 3.1.2.2 Small power units (complete power units) ........................................................................ 9 3.1.2.3 Filling: .............................................................................................................................. 10 3.1.2.4 Pump start-up and pump safety block ............................................................................ 10 3.1.2.4.1 Solenoid with reduced electric power consumption (8 Watts) ....................................... 10 3.1.2.4.2 With standard solenoid (30 Watts) and cubic connector ............................................... 10 3.1.3 Breather .......................................................................................................................... 11 3.1.4 Pressure measurement and indicating devices .............................................................. 11 3.1.4.1 Mechanical instruments .................................................................................................. 11 3.1.4.2 Electronic instruments .................................................................................................... 11 3.1.5 Filters .............................................................................................................................. 12 3.1.5.1 Maintenance indicator (electronic switching element) .................................................... 12 3.1.5.2 Single filter ...................................................................................................................... 12 3.1.5.2.1 Inline filter in return flow or bypass circuit: Nominal pressure 50 bar (with bypass) ...... 12 3.1.5.2.2 Inline filter in main flow (without bypass) ....................................................................... 12 3.1.5.3 Duplex switch filter .......................................................................................................... 13 3.1.5.3.1 Duplex switch filter in return flow or bypass – nominal pressure 50 bar (with bypass) . 13 3.1.5.3.2 Duplex switch filter in main flow (without bypass) ......................................................... 13 3.1.6 Oil-water heat exchangers .............................................................................................. 14 3.1.7 Thermostat ...................................................................................................................... 14 3.1.8 Accumulators .................................................................................................................. 14 3.1.8.1 Diaphragm type accumulator .......................................................................................... 14 3.1.8.2 Blader-type accumulator ................................................................................................. 14 3.1.8.3 Accumulator shut-off block (with electrical unloading) .................................................... 14 3.1.8.4 Accumulator charging valve ............................................................................................ 14 3.1.8.5 Isolator valve with test connection .................................................................................. 14 3.2 Control devices ............................................................................................................... 15 3.2.1 Directional valves ............................................................................................................ 15 3.2.1.1 Spool valves – direct operated ....................................................................................... 15 3.2.1.1.1 Size 6 – solenoid with reduced electric power consumption (8 Watts) ......................... 15 3.2.1.1.2 Size 6 – with standard solenoid (30 Watts) and cubic connector .................................. 17 3.2.1.1.3 Size 10 – with reduced electric power consumption (8 Watts) ...................................... 19 3.2.1.1.4 Size 10 with standard solenoid (30 Watts) and cubic connector ................................... 19 3.2.1.2 Spool valves – pilot operated .......................................................................................... 20 3.2.1.2.1 Size 10 – with standard solenoid (30 Watts) and cubic connector ................................ 20 3.2.1.2.2 Size 16 (pmax 280 bar) – with standard solenoid (30 Watts) and cubic connector ......... 20 3.2.1.2.3 Size 22/25 – with standard solenoid (30 Watts) and cubic connector ........................... 20 3.2.1.2.4 Size 32 – with standard solenoid (30 Watts) and cubic connector ................................ 21 3.2.1.3 Size 6 seat valves – with standard solenoid (30 Watts) and cubic connector ................ 21 3.2.2 Isolator valves ................................................................................................................. 21 3.2.2.1 Check valves ................................................................................................................... 21 3.2.2.1.1 Inline valves ................................................................................................................... 21 3.2.2.1.2 Subplate mounted valves .............................................................................................. 21 3.2.2.1.3 Sandwich plate valves ................................................................................................... 22
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 4 of 59
3.2.3 Pressure valves .............................................................................................................. 23 3.2.3.1 Pressure relief valves ..................................................................................................... 23 3.2.3.1.1 Direct operated .............................................................................................................. 23 3.2.3.1.2 Pilot operated ................................................................................................................. 25 3.2.3.2 Pressure reducing valves ............................................................................................... 26 3.2.3.2.1 Direct operated .............................................................................................................. 26 3.2.3.2.2 Pilot operated ................................................................................................................. 28 3.2.3.2.3 Pressure sequencing valves .......................................................................................... 29 3.2.4 Flow control valves ......................................................................................................... 29 3.2.4.1 Throttle valves ................................................................................................................. 29 3.2.4.1.1 Pipe fitting ...................................................................................................................... 29 3.2.4.2 Throttle check valves ...................................................................................................... 29 3.2.4.2.1 Pipe fitting ...................................................................................................................... 29 3.2.4.2.2 Sandwich plate valves ................................................................................................... 30 3.2.4.3 Flow control valves ......................................................................................................... 30 3.2.4.3.1 Subplate mounted valves .............................................................................................. 30 3.2.4.3.2 Sandwich plate valves ................................................................................................... 30 3.2.4.3.3 Screw-in cartridge valves ............................................................................................... 31 3.3 Cylinders ......................................................................................................................... 31 3.3.1 Tie rod cylinders .............................................................................................................. 31 3.4 Accessories ..................................................................................................................... 31 3.4.1 Adapter and cover plates ................................................................................................ 31 3.4.1.1 Adapter for mating connector ......................................................................................... 31 3.4.1.2 Cover plates .................................................................................................................... 31
4 Data sheets ..................................................................................................................... 32 4.1 Small power units............................................................................................................ 32 4.1.1 ABSKG-40AL9/VGF2-006/90L/1NT/VW-PT Order no. R901 339 394........................... 32 4.1.2 ABSKG-40AL9/VGF2-006/100L/1NT/VW-PT Order no. R901 339 393......................... 33 4.1.3 ABSKG-40AL9/VGF2-011/100L/1NT/VW-PT Order no. R901 339 392......................... 34 4.1.4 ABSKG-40AL9/VGF2-11/132M/1NT/VW-PT Order no. R901 339 391.......................... 35 4.1.5 ABSKG-60AL9/VGF2-16/112M/1NT/VW-PT Order no. R901 339 390.......................... 36 4.1.6 ABSKG-60AL9/VGF2-16/132M/1NT/VW-PT Order no. R901 339 389.......................... 37 4.1.7 ABSKG-60AL9/HV7-10-4/100L/1NT/VW-PT Order no. R901 339 388 .......................... 38 4.1.8 ABSKG-60AL9/HV7-10-4/132S/1NT/VW-PT Order no.. R901 339 387 ........................ 39
5 Systems with flame-resistant hydraulic fluids of the HFC group .................................... 40 5.1 Pump station with tank and accessories ........................................................................ 41 5.1.1 Pumps ............................................................................................................................. 41 5.1.1.1 Fixed displacement pumps – internal gear pumps ......................................................... 41 5.1.1.2 Variable displacement pumps – axial piston pumps ....................................................... 41 5.1.2 Reservoir ......................................................................................................................... 41 5.1.2.1 Reservoir 100 to 1000 l (DIN-24339, type BN, cover type A) ......................................... 41 5.1.3 Air Breather ..................................................................................................................... 41 5.1.4 Pressure measurement and indicating devices .............................................................. 41 5.1.5 Filters .............................................................................................................................. 42 5.1.5.1 Clogging indicator ........................................................................................................... 42 5.1.5.2 Inline filter in return flow .................................................................................................. 42 5.1.5.2.1 Filter bowl can be unscrewed to the bottom: Standard pressure rating 250 bar ........... 42 5.1.5.2.2 Filter bowl can be unscrewed to the top: Standard pressure rating 100 bar ................. 43 5.1.5.2.3 Filter bowl can be unscrewed to the top: Standard pressure rating 250 bar ................. 43 5.1.5.3 Inline filter in bypass circuit ............................................................................................. 43 5.1.5.3.1 Filter bowl can be unscrewed to the bottom: Standard pressure rating 250 bar ........... 43 5.1.5.3.2 Filter bowl can be unscrewed to the top: Standard pressure rating 100 bar ................. 43 5.1.5.3.3 Filter bowl can be unscrewed to the top: Standard pressure rating 250 bar ................. 43 5.1.5.4 Inline filter in main flow ................................................................................................... 44 5.1.5.4.1 Medium pressure standard pressure rating 250 bar ...................................................... 44 5.1.5.4.2 High pressure standard pressure rating 400 bar ........................................................... 44 5.1.5.5 Replacement elements ................................................................................................... 45 5.1.5.5.1 Pressure differential resistance (collapse pressure) 30 bar .......................................... 45
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 5 of 59
5.1.5.5.2 Pressure differential resistance (collapse pressure) 330 bar ........................................ 45 5.1.6 Oil-water heat exchangers .............................................................................................. 46 5.1.7 Thermostat ...................................................................................................................... 46 5.1.8 Accumulators .................................................................................................................. 46 5.1.8.1 Accumulator tank ............................................................................................................ 46 5.1.8.2 Accumulator shut-off block (with manual unloading) ...................................................... 46 5.1.8.3 Isolator valve with test connection .................................................................................. 46 5.2 Control devices ............................................................................................................... 47 5.2.1.1 Spool valves – direct operated ....................................................................................... 47 5.2.1.1.1 Size 6 ............................................................................................................................. 47 5.2.1.1.2 Size 10 ........................................................................................................................... 47 5.2.1.2 Spool valves – pilot operated .......................................................................................... 48 5.2.1.2.1 Size 16 (pmax 280 bar) .................................................................................................... 48 5.2.1.2.2 Sizes 25 and 32 ............................................................................................................. 48 5.2.1.3 Poppet valves (350 bar, leakage oil-free) ....................................................................... 48 5.2.2 2-way cartridge valves .................................................................................................... 49 5.2.2.1 Cartridge valves .............................................................................................................. 49 5.2.2.2 Control cover ................................................................................................................... 49 5.2.3 Isolator valves ................................................................................................................. 50 5.2.3.1 Check valves ................................................................................................................... 50 5.2.3.1.1 Pipe installation .............................................................................................................. 50 5.2.3.1.2 Plate cartridge valves (angle valves) ............................................................................. 50 5.2.3.1.3 Sandwich plate valves ................................................................................................... 50 5.2.3.2 Check valves – hydraulically pilot operated .................................................................... 51 5.2.3.2.1 Pipe installation .............................................................................................................. 51 5.2.3.2.2 Subplate mounting ......................................................................................................... 51 5.2.3.2.3 Sandwich plate design ................................................................................................... 51 5.2.4 Pressure valves .............................................................................................................. 52 5.2.4.1 Pressure relief valves ..................................................................................................... 52 5.2.4.1.1 Direct operated .............................................................................................................. 52 5.2.4.1.2 Pilot operated ................................................................................................................. 53 5.2.4.2 Pressure reducing valves ............................................................................................... 54 5.2.4.2.1 Direct operated .............................................................................................................. 54 5.2.4.2.2 Pilot operated ................................................................................................................. 55 5.2.5 Flow control valves ......................................................................................................... 56 5.2.5.1 Throttle valves ................................................................................................................. 56 5.2.5.1.1 Pipe fitting ...................................................................................................................... 56 5.2.5.2 Throttle check valves ...................................................................................................... 56 5.2.5.2.1 Pipe fitting ...................................................................................................................... 56 5.2.5.2.2 Sandwich plate valves ................................................................................................... 56 5.2.5.3 Flow control valves ......................................................................................................... 57 5.2.5.3.1 Subplate mounted valves .............................................................................................. 57 5.2.5.3.2 Screw-in cartridge valves ............................................................................................... 57 5.3 Proportional and servo valves ........................................................................................ 58 5.3.1 Directional valves ............................................................................................................ 58 5.3.1.1 Spool valves .................................................................................................................... 58 5.3.1.2 High-response cartridge valve 2-way and 3-way version ............................................. 58 5.3.2 Pressure valves: Pressure relief valves .......................................................................... 58 5.3.3 Flow control valves: 2-way proportional throttle valve for block installation ................... 58 5.4 Cylinders ......................................................................................................................... 59 5.4.1 Tie rod cylinders .............................................................................................................. 59 5.5 Accessories ..................................................................................................................... 59 5.5.1 Cover plates .................................................................................................................... 59
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 6 of 59
1 Contacts
Central Bosch Rexroth Hydraulics contact:
Bosch Rexroth AG Johannes E. Gebauer Global Account Management Technology Support for Hydraulics Zum Eisengießer 1 97816 Lohr Tel. +49 (0) 9352-18-1071 Fax +49 (0) 711-811-5171021 E-mail: johannes.gebauer@boschrexroth.de
Bosch Rexroth Hydraulics contact for Volkswagen AG and Volkswagen Sachsen GmbH:
Bosch Rexroth AG Stefan Bödecker Regionalzentrum Nord – Geschäftsbereich Hydraulik Walsroder Strasse 93 30853 Hannover-Langenhagen Tel. +49 (0) 5361-89354-857-537 Fax +49 (0) 511-726657-93 E-mail: stefan.boedecker@boschrexroth.de
Bosch Rexroth Hydraulics contact for AUDI AG:
Bosch Rexroth AG Hans-Jürgen Hierling Regionalzentrum Süd – Geschäftsbereich Hydraulik Landshuter Alle 8-10 80637 München Tel. +49 (0 )89-12714-323 Fax +49 (0) 89-12714-390 E-mail: hans-juergen.hierling@boschrexroth.de
Bosch Rexroth Hydraulics contact for Škoda Auto:
Roman Jaroš Škoda Auto Bosch Rexroth spol.s.r.o. Plant M4 Tezebni 2 CZ 293 60 Mladá Boleslav CZ-627 00 Brno Tel. +420 (0) 728 819 600 Fax +420 (0) 5-48 126-106 E-mail: roman.jaros@boschrexroth.cz
Bosch Rexroth Hydraulics contact for Volkswagen Motor Polska:
Bosch Rexroth SP.z.o.o. Slawomir Sokólski Ul Wymyslowskiego 3 55-080 Nowa Wies Wroclawska Tel. +48 (0) 71 364 - 73 22 Fax +48 (0) 71 364 - 73 24 E-mail: slawomir.sokolski@boschrexroth.pl
Bosch Rexroth Hydraulics service hotline
Mon. – Fri., 07:00 a.m to 05:00 p.m: +49 (0) 93 52 / 18 - 46 66 outside of office opening hours: +49 (0) 1 73 / 3 63 60 36
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 7 of 59
2 Notes The following table (chapters 3 and 4) lists all components that may be used when designing mineral-oil hydraulic systems (used medium: HLP-D) for the plants of the VOLKSWAGEN group specified on page 1. When using HFC fluids (reference oil "Ultrasafe 620" by Petrofer) the provisions and specification in chapter 6 must be complied with.
The use of components that are not listed in this table requires a written special authorization. A special authorization is not required if the component is not an active functional element. This includes: Steel components, assembly parts, subplates, cover plates and sandwich plates without hydraulic function, orifice inserts, individual, standard and serial control blocks, manifolds (e.g. type HSR) and stacking systems (e. g. type IH20) and card holders for amplifier cards.
The Global Account Management, division DC-IA/SFA11, of Bosch Rexroth AG is responsible for the creation and maintenance of this document. It was compiled in cooperation with Volkswagen AG.
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 8 of 59
3 Overview All components with locking functions are marked with a lock "“ symbol. All components that are used have to be free of chromium VI. Carry out all labels in the planning language and in the language at the plant´s location.
3.1 Pump station with tank and accessories
3.1.1 Pumps
3.1.1.1 Fixed displacement pumps (gear pumps)
Designation (type) Techn. data Order number (manufacturer) Data sheet
PGF2-2X/006RE01VE4 210 bar; 9.4 l/min with n=1450 R900 932 265
10 213
PGF2-2X/011RE01VE4 210 bar; 16 l/min with n=1450 R900 932 271 PGF2-2X/013RE20VE4 210 bar; 19.3 l/min with n=1450 R900 943 181 PGF2-2X/016RE20VE4 210 bar; 23.2 l/min with n=1450 R900 932 193 PGF3-3X/025RE07VE4 210 bar; 36.8 l/min with n=1450 R900 932 088 PGF3-3X/032RE07VE4 210 bar; 47.1 l/min with n=1450 R900 932 112 PGF3-3X/040RE07VE4 210 bar; 58.7 l/min with n=1450 R900 932 111 PGH5-3X/063RE11VE4 250 bar; 92.8 l/min with n=1450 R901 147 122
10 227 PGH5-3X/080RE11VE4 250 bar; 116.9 l/min with n=1450 R901 147 123 PGH5-3X/100RE11VE4 250 bar; 143.8 l/min with n=1450 R901 147 124 http://www.boschrexroth.com/various/utilities/mediadirectory/index.jsp?publication=NET&pagesize=50&search_action=submit?& search_query= 3.1.1.2 Variable displacement pumps 3.1.1.2.1 Vane pumps
Designation (type) Techn. data Order number (manufacturer) Data sheet
PV7-1X/10-14RE01MC3-16 160 bar; 21 l/min with n=1450 R900 598 753
10 515
PV7-1X/16-20RE01MC3-16 160 bar; 29 l/min with n=1450 R900 592 237 PV7-1X/25-30RE01MC3-16 160 bar; 43.5 l/min with n=1450; R900 586 235 PV7-1X/40-45RE37MC3-16 160 bar; 66 l/min with n=1450 R900 590 087 PV7-1X/63-71RE07MC3-16 160 bar; 108 l/min with n=1450 R900 511 215 PV7-1X/100-118RE07MC3-16 160 bar; 171 l/min with n=1450 R900 511 215 3.1.1.2.2 Axial piston pumps
Designation (type) Techn. data Order number (manufacturer) Data sheet
A10VSO18DFR1/31R-PPA12N00SO155 280 bar; 27 l/min with n=1450 R910 966 386
92 711
A10VSO28DFR1/31R-PPA12N00SO155 280 bar; 42 l/min with n=1450 R910 969 498 A10VSO45DFR1/31R-PPA12N00SO155 280 bar; 68 l/min with n=1450 R910 921 747 A10VSO71DFR1/31R-PPA12N00SO155 280 bar; 107 l/min with n=1450 R910 985 257 A10VSO100DFR1/31R-PPA12N00SO155 280 bar; 150 l/min with n=1450 R910 966 342 A10VSO28DFLR/31R-PPA12N00 Power controller specification required XXXX XXX XXX A10VSO45DFLR/31R-PPA12N00 Power controller specification required XXXX XXX XXX A10VSO71DFLR/31R-PPA12N00 Power controller specification required XXXX XXX XXX A10VSO100DFLR/31R-PPA12N00 Power controller specification required XXXX XXX XXX A10VSO140DFLR/31R-PPA12N00 Power controller specification required XXXX XXX XXX
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 9 of 59
3.1.2 Tanks and small power units
3.1.2.1 Tanks 100 to 1000 l (DIN-24339, type BN, cover type A)
Nominal tank volume [liters] 100 160 250 400 630 800 1000
R90
1 16
2 67
8
R90
1 16
2 67
9
R90
1 16
2 68
0
R90
1 16
2 68
1
R90
1 16
2 68
2
R90
1 16
2 68
3
R90
1 16
2 68
4
Order no. Denomination 1 1 1 2 R900 543 908 Closure AB40-19/324A-AL/M-6 1 1 1 2 R900 320 727 Closure AB40-19/449A-AL/M 2 2 2 R900 007 824 Oil level indicator AB31-21/127 1 1 1 1 1 1 2 R900 002 424 Pug screw G1-A3C-NBR 143.21 1 1 1 1 1 1 1 R901 201 071 Ball valve ABZAK-G-025-
040/2LMM3D/V/N 1 1 1 1 1 1 1
R900 762 370 Level sensor LK7022 + E43001 1 1 1 1 1 1 1 R900 026 428 Label AB31-21/MIN 1 1 1 1 1 1 1 R900 026 429 Label AB31-21/MAX 1 1 1 1 1 1 1 R901 278 209 Thermostat TT3050+E35030+TR7432 1 1 1 1 1 1 1 R900 241 093 Label AB30-11/yellow-100 ltr.+ oil grade + VW
no. 1
R900 241 092 Label AB30-11/yellow-160 ltr. + oil grade + VW no.
1
R900 241 091 Label AB30-11/yellow-250 ltr. + oil grade + VW no.
1
R900 241 090 Label AB30-11/yellow-400 ltr. + oil grade + VW no.
1
R900 241 088 Label AB30-11/yellow-630 ltr. + oil grade + VW no.
1
R900 241 087 Label AB30-11/yellow-800 ltr. + oil grade + VW no.
1
R900 241 076 Label AB30-11/yellow-1000 ltr. + oil grade + VW no.
1
3.1.2.2 Small power units (complete power units)
- El. motors up to 5.5. kW have to be equipped with a plug-in connection (plug-in connectors on terminal box)
- Installation drawings: See chapter 4 - Filling coupling as described in chapter 3.1.2.1 but with orifice Ø 3 mm in the tank line
Designation (type) Techn. data
Order number (manufacturer) Data sheet
ABSKG-40AL9/VGF2-006/90L/1NT/VW-PT 9.4 l/min; up to 75 bar; 1.5 kW R901 339 394
51 013
ABSKG-40AL9/VGF2-006/100L/1NT/VW-PT 9.4 l/min; up to 160 bar; 3 kW R901 339 393 ABSKG-40AL9/VGF2-011/100L/1NT/VW-PT 16 l/min; up to 100 bar; 3 kW R901 339 392 ABSKG-40AL9/VGF2-11/132M/1NT/VW-PT 16 l/min; up to 175 bar; 5.5 kW R901 339 391 ABSKG-60AL9/VGF2-16/112M/1NT/VW-PT 23.2 l/min; up to 80 bar; 4 kW R901 339 390 ABSKG-60AL9/VGF2-16/132M/1NT/VW-PT 23.2 l/min; up to 175 bar; 7,5 kW R901 339 389 ABSKG-60AL9/HV7-10-4/100L/1NT/VW-PT up to 21 l/min; up to 69 bar; 3 kW R901 339 388 ABSKG-60AL9/HV7-10-4/132S/1NT/VW-PT up to 21 l/min; up to 126 bar; 5.5 kW R901 339 387
Material number for accessory set (without tank) according to the following table
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 10 of 59
3.1.2.3 Filling: - Filling couplings have to be used in any case. - If an inline filter is installed in the return flow, the filling nipple is to be modified so as to ensure filling via the
filter. Designation (type) Techn. data
Order number (manufacturer) Data sheet
Coupling plug MD-012-2-WR033-19-1 R900 068 245 Make Walther Dust protection cap MD-012-5-74 KU R900 030 420
For the Salzgitter plant, a filling circuit with additional filling level sensor is required:
Base plate G3/4 G534/01 R900 467 259 48 054
Sandwich plate HSZ10A079-3X/M00 R900 537 265 48 052
Adapter plate HSE10B06A001-31/M00 R900 303 948 48 045
Directional valve 4WE6D6X/EG24N9K72L SO407 R901 235 380 23 178-00
In systems where (upon approval by the responsible technical department of the final customer) standard solenoids (30 Watts) are employed, the directional valve type 4WE6D6X/EG24N9K4, order no. R900 561 274 are to be used.
Designation (type) Techn. data Order number (manufacturer) Data sheet
Filling level sensor (optional) LK1222 R901 120 129 Make: ifm Filling level sensor (optional) LK8122 R901 076 785 Make: ifm
3.1.2.4 Pump start-up and pump safety block 3.1.2.4.1 Solenoid with reduced electric power consumption (8 Watts)
NOTE: Place notice on mounting plate. DC24V; circular plug-in connector M12x1 according to IEC 61076-2-101 m. LED; concealed manual override Pump start-up and pump safety blocks are available in version "SO803"! (Pilot valve with reduced electric power consumption – 8 Watts)
3.1.2.4.2 With standard solenoid (30 Watts) and cubic connector
May only be used after approval by the responsible technical department of the final customer! DC24V; plug-in connector design A according to EN175301-803 m. LED; concealed manual override
Designation (type) Techn. data Order number (manufacturer) Data sheet
DBAW15BF2-2X/100U6EG24N9K4 Pump safety block Upon request
25 891
DBAW30BH2-2X/100Z6EG24N9K4 Pump safety block R900 978 920 DBAW15BF3-2X/100U6EG24N9K4 Pump safety block R900 964 599 DBAW25BH2-2X/200-6EG24N9K4 Pump safety block R900 969 376 DBAW30BH2-2X/200-6EG24N9K4 Pump safety block R900 955 670 DBAW30BH3-2X/200-6EG24N9K4 Pump safety block R900 954 831 DBAW30BH2-2X/315-6EG24N9K4 Pump safety block; R900 957 485 DBAW30BH3-2X/315-6EG24N9K4 Pump safety block; R901 194 365
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 11 of 59
3.1.3 Breather
- with clogging indicator - filling protection
Designation (type) Techn. data Order number Data sheet
Air breather filter PI0125 SM-L/UM-OS Mounting 6 x M5, hole circle Ø 73 mm R901 064 797 see Mahle
3.1.4 Pressure measurement and indicating devices
3.1.4.1 Mechanical instruments
Designation (type) Techn. data Order number (manufacturer) Data sheet
MS4A2X/ Indication up to 315 bar, 6 connections R900 421 643
50 034 MSL2A2X/180 Indication up to 180 bar; 6 connections; leak-free R900 386 956
MSL2A2X/315 Indication up to 315 bar; 6 connections; leak-free R900 393 896
AB42-15/10-100AM1 Pressure control unit with pressure gauge R901 064 994 AB42-15
AB42-15/10-200AM1 Pressure control unit with pressure gauge R900 827 581 AB42-15
3.1.4.2 Electronic instruments
(Selection analogous to IFM)
Designation (type) Techn. data Order number (manufacturer) Data sheet
HEDE10A12X/100K41G24/1/V DC24V;M12x1, digit. display, 1 switch, 1 analogue up to 100 bar R901 022 831
30 276 HEDE10A12X/250K41G24/1/V DC24V;M12x1, digit. display, 1 switch, 1 analogue up to 250 bar R901 022 922
HEDE10A12X/400K41G24/1/V DC24V;M12x1, digit. display, 1 switch, 1 analogue up to 400 bar R901 022 978
HEDE10A12X/100K41G24/2/V DC24V;M12x1, digit. display, 2 switches, up to 100 bar
R901 023 071
30 278 HEDE10A12X/250K41G24/2/V DC24V;M12x1, digit. display, 2 switches, up to 250 bar
R901 023 091
HEDE10A12X/400K41G24/2/V DC24V;M12x1, digit. display, 2 switches, up to 400 bar
R901 023 142
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 12 of 59
3.1.5 Filters
The installation of duplex switch filters may be required (according to plant-specific specifications) (only use switching point "100 %" for maintenance indicator). Refer to: Chapter 3.1.5.3
3.1.5.1 Maintenance indicator (electronic switching element)
Designation (type) Techn. data Order number (manufacturer) Data sheet
WE-2SP-M12x1 M12x1, 75 %, 100 % R928 028 410 51 450 3.1.5.2 Single filter 3.1.5.2.1 Inline filter in return flow or bypass circuit: Nominal pressure 50 bar (with bypass)
Designation (type) Techn. data Order number (manufacturer) Data sheet
50LEN0160-H10XLA00-V2,2-M-R6 up to 100 l/min, cleanliness class 17/15/11 R928 051 125
51 447
50LEN0250-H10XLA00-V2,2-M-R6 up to 150 l/min, cleanliness class 17/15/11 R928 051 204 50LEN0400-H10XLA00-V2,2-M-R6 up to 175 l/min, cleanliness class 17/15/11 R928 051 284 50LEN0160-H3XLA00-V2,2-M-R6 up to 48 l/min, cleanliness class 14/12/09 R928 051 152 50LEN0250-H3XLA00-V2,2-M-R6 up to 95 l/min, cleanliness class 14/12/09 R928 051 232 50LEN0400-H3XLA00-V2,2-M-R6 up to 125 l/min, cleanliness class 14/12/09 R928 051 312 3.1.5.2.2 Inline filter in main flow (without bypass)
3.1.5.2.2.1 Medium pressure: Nominal pressure 250 bar
Designation (type) Techn. data Order number (manufacturer) Data sheet
245LEN0100H10XLB00-V5,0-M-R4 up to 83 l/min, cleanliness class 17/15/11 R928 030 546
51 421
245LEN0160H10XLB00-V5,0-M-R6 up to 165 l/min, cleanliness class 17/15/11 R928 030 549 245LEN0250H10XLB00-V5,0-M-R6 up to 210 l/min, cleanliness class 17/15/11 R928 030 550 245LEN0400H10XLB00-V5,0-M-R6 up to 230 l/min, cleanliness class 17/15/11 R928 030 551 245LEN0100H3XLB00-V5,0-M-R4 up to 40 l/min, cleanliness class 14/12/09 R928 030 034 245LEN0160H3XLB00-V5,0-M-R6 up to 92 l/min, cleanliness class 14/12/09 R928 030 037 245LEN0250H3XLB00-V5,0-M-R6 up to 142 l/min, cleanliness class 14/12/09 R928 030 038 245LEN0400H3XLB00-V5,0-M-R6 up to 165 l/min, cleanliness class 14/12/09 R928 030 039
3.1.5.2.2.2 High pressure: Nominal pressure 350 bar
Designation (type) Techn. data Order number (manufacturer) Data sheet
350LEN0100H10XLB00-V5,0-M-R4 up to 78 l/min, cleanliness class 17/15/11 R928 033 546
51 422
350LEN0160H10XLB00-V5,0-M-R6 up to 155 l/min, cleanliness class 17/15/11 R928 033 549 350LEN0250H10XLB00-V5,0-M-R6 up to 250 l/min, cleanliness class 17/15/11 R928 033 550 350LEN0400H10XLB00-V5,0-M-R6 up to 350 l/min, cleanliness class 17/15/11 R928 033 551 350LEN0100H3XLB00-V5,0-M-R4 up to 43 l/min, cleanliness class 14/12/09 R928 033 034 350LEN0160H3XLB00-V5,0-M-R6 up to 90 l/min, cleanliness class 14/12/09 R928 033 037 350LEN0250H3XLB00-V5,0-M-R6 up to 160 l/min, cleanliness class 14/12/09 R928 033 038 350LEN0400H3XLB00-V5,0-M-R6 up to 230 l/min, cleanliness class 14/12/09 R928 033 039
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 13 of 59
3.1.5.3 Duplex switch filter 3.1.5.3.1 Duplex switch filter in return flow or bypass – nominal pressure 50 bar (with bypass)
Designation (type) Techn. data
Order number (manufacturer) Data sheet
50LDN0100-H10XLA00-V2,2-M-R4 up to 29 l/min, cleanliness class 17/15/11 R928 039 374
51 453
50LDN0160-H10XLA00-V2,2-M-R6 up to 81 l/min, cleanliness class 17/15/11 R928 039 358 50LDN0250-H10XLA00-V2,2-M-R6 up to 102 l/min, cleanliness class 17/15/11 R928 039 360 50LDN0400-H10XLA00-V2,2-M-R6 up to 122 l/min, cleanliness class 17/15/11 R928 039 362 50LDN0100-H3XLA00-V2,2-M-R4 up to 15 l/min, cleanliness class 14/12/09 R928 039 375 50LDN0160-H3XLA00-V2,2-M-R6 up to 38 l/min, cleanliness class 14/12/09 R928 039 359 50LDN0250-H3XLA00-V2,2-M-R6 up to 56 l/min, cleanliness class 14/12/09 R928 039 361 50LDN0400-H3XLA00-V2,2-M-R6 up to 78 l/min, cleanliness class 14/12/09 R928 039 363 3.1.5.3.2 Duplex switch filter in main flow (without bypass)
3.1.5.3.2.1 Nominal pressure 50 bar
Designation (type) Techn. data
Order number (manufacturer) Data sheet
50LDN0100-H10XLB00-V2,2-M-R4 up to 29 l/min, cleanliness class 17/15/11 R928 051 425
51 453
50LDN0160-H10XLB00-V2,2-M-R6 up to 81 l/min, cleanliness class 17/15/11 R928 049 976 50LDN0250-H10XLB00-V2,2-M-R6 up to 102 l/min, cleanliness class 17/15/11 R928 049 978 50LDN0400-H10XLB00-V2,2-M-R6 up to 122 l/min, cleanliness class 17/15/11 R928 049 981 50LDN0100-H3XLB00-V2,2-M-R4 up to 15 l/min, cleanliness class 14/12/09 R928 051 427 50LDN0160-H3XLB00-V2,2-M-R6 up to 38 l/min, cleanliness class 14/12/09 R928 051 428 50LDN0250-H3XLB00-V2,2-M-R6 up to 56 l/min, cleanliness class 14/12/09 R928 051 429 50LDN0400-H3XLB00-V2,2-M-R6 up to 78 l/min, cleanliness class 14/12/09 R928 051 431
3.1.5.3.2.2 Nominal pressure 160 bar
Designation (type) Techn. data
Order number (manufacturer) Data sheet
150LDN0100-H10XLB00-V5,0-M-R4 up to 42 l/min, cleanliness class 17/15/11 R928 048 673
51 446
150LDN0160-H10XLB00-V5,0-M-R6 up to 118 l/min, cleanliness class 17/15/11 R928 041 756 150LDN0250-H10XLB00-V5,0-M-R6 up to 148 l/min, cleanliness class 17/15/11 R928 044 799 150LDN0400-H10XLB00-V5,0-M-R6 up to 172 l/min, cleanliness class 14/12/09 R928 046 724 150LDN0100-H3XLB00-V5,0-M-R4 up to 23 l/min, cleanliness class 14/12/09 R928 051 432 150LDN0160-H3XLB00-V5,0-M-R6 up to 58 l/min, cleanliness class 14/12/09 R928 051 433
150LDN0250-H3XLB00-V5,0-M-R6 up to 84 l/min, cleanliness class 14/12/09 R928 051 345 150LDN0400-H3XLB00-V5,0-M-R6 up to 115 l/min, cleanliness class 14/12/09 R928 046 729
3.1.5.3.2.3 Nominal pressure 400 bar
Designation (type) Techn. data
Order number (manufacturer) Data sheet
400LDN0100-H10XLB00-V5,0-M-R2 up to 38 l/min, cleanliness class 17/15/11 R928 038 550
51 429
400LDN0160-H10XLB00-V5,0-M-S6 up to 157 l/min, cleanliness class 17/15/11 R928 039 283 400LDN0250-H10XLB00-V5,0-M-S6 up to 195 l/min, cleanliness class 17/15/11 R928 039 284 400LDN0400-H10XLB00-V5,0-M-S6 up to 230 l/min, cleanliness class 17/15/11 R928 038 551 400LDN0100-H3XLB00-V5,0-M-R2 up to 25 l/min, cleanliness class 14/12/09 R928 039 413 400LDN0160-H3XLB00-V5,0-M-S6 up to 80 l/min, cleanliness class 14/12/09 R928 039 417 400LDN0250-H3XLB00-V5,0-M-S6 up to 110 l/min, cleanliness class 14/12/09 R928 039 418 400LDN0400-H3XLB00-V5,0-M-S6 up to 150 l/min, cleanliness class 14/12/09 R928 039 419
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 14 of 59
3.1.6 Oil-water heat exchangers
Designation (type) Techn. data Order number (manufacturer) Data sheet
Heat exchanger AB32-12/00-K-006-22 4 kW (18 l/min); up to 10 bar R900 028 816 AB 32-12
3.1.7 Thermostat Attention: Already included in assembly kit for reservoirs according to chapt. 4.1.2.1!
Designation (type) Techn. data Order number (manufacturer) Data sheet
Thermostat TT3050*E35030+TR7432 2 x normally open/normally closed contacts, programmable R901 278 209 by IFM
3.1.8 Accumulators
3.1.8.1 Diaphragm type accumulator
Designation (type) Techn. data Order number (manufacturer) Data sheet
HAD1,0-200-1X/2G04E-1N111-BA 1 liter R901 164 367 50 150 3.1.8.2 Blader-type accumulator
Accumulators of the type "HAB...-350-4X/..." are not permitted!
Designation (type) Techn. data Order number (manufacturer) Data sheet
HAB10-330-4X/2G09G-2N111-CE- 10 liters R901 195 139 50 170 HAB20-330-4X/2G09G-2N111-CE- 20 liters R901 195 141
HAB35-330-4X/2G09G-2N111-CE- 35 liters R901 195 143 3.1.8.3 Accumulator shut-off block (with electrical unloading)
Designation (type) Techn. data Order number (manufacturer) Data sheet
ABZSS10E-3X/330E/S10G24K4V Pressure relief valve sealed at 330 bar R900 709 606
50 131 ABZSS10E-3X/330E/S12G24K4V Pressure relief valve sealed at 330 bar R900 709 607 ABZSS20E-3X/330E/S13G24K4V Pressure relief valve sealed at 330 bar R900 709 636 ABZSS30E-3X/330E/S309G24K4V Pressure relief valve sealed at 330 bar R900 709 657
ADAPTER K4 ON M12X1 for ABZSS..E (electrically actuated accumulator draining)
R901 034 223 ---
3.1.8.4 Accumulator charging valve
Designation (type) Techn. data Order number (manufacturer) Data sheet
DA6VA2A5X/50FSM up to 50 bar; up to 30 l/min; var. switching diff. R901 224 225
26 405 DA6VA2A5X/100FSM up to 100 bar; up to 30 l/min; var. switching diff. R901 224 217
DA6VA2A5X/200FSM up to 200 bar; up to 30 l/min; var. switching diff. R901 224 218
3.1.8.5 Isolator valve with test connection
Designation (type) Techn. data Order number (manufacturer) Data sheet
Isolator valve AB42-02/AMR-PA for safety block; up to 400 bar; G1/2 R900 015 297 AB 42-02
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 15 of 59
3.2 Control devices
3.2.1 Directional valves
3.2.1.1 Spool valves – direct operated 3.2.1.1.1 Size 6 – solenoid with reduced electric power consumption (8 Watts)
NOTE: Place notice on mounting plate. DC24V; circular plug-in connector M12x1 according to IEC 61076-2-101 w. LED; concealed manual override Standard Designation (type) Techn. data
Order number (manufacturer) Data sheet
3WE6A6X/EG24N9K72L SO407
R901 241 328
23 178-00
3WE6B6X/EG24N9K72L SO407
R901 241 330
4WE6C6X/EG24N9K72L SO407
R901 241 335
4WE6D6X/EG24N9K72L SO407
R901 235 380
4WE6D46-6X/OFEG24N9K72L SO407
R901 235 381
4WE6E6X/EG24N9K72L SO407
R901 235 382
4WE6G6X/EG24N9K72L SO407
R901 241 337
4WE6H6X/EG24N9K72L SO407
R901 241 338
4WE6HA6X/EG24N9K72L SO407
R901 241 345
4WE6J6X/EG24N9K72L SO407
R901 235 379
4WE6M6X/EG24N9K72L SO407
R901 241 348
4WE6Q6X/EG24N9K72L SO407
R901 235 367
4WE6U6X/EG24N9K72L SO407
R901 241 349
4WE6Y6X/EG24N9K72L SO407
R901 241 350
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 16 of 59
3.2.1.1.1.1 Smoothly switching
Designation (type) Techn. data Order number (manufacturer) Data sheet
4WE6D73-6X/EG24N9K72L SO407
Upon request
23 178-00
4WE6D73-6X/OFEG24N9K72L SO407
R901 262 594
4WE6E73-6X/EG24N9K72L SO407
Upon request
4WE6G73-6X/EG24N9K72L SO407
Upon request
4WE6H73-6X/EG24N9K72L SO407
Upon request
4WE6J73-6X/EG24N9K72L SO407
R901 235 389
4WE6U73-6X/EG24N9K72L SO407
Upon request
4WE6W73-6X/EG24N9K72L SO407
R901 243 071
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 17 of 59
3.2.1.1.2 Size 6 – with standard solenoid (30 Watts) and cubic connector May only be used after approval by the responsible technical department of the final customer! DC24V; plug-in connector design A according to EN175301-803 w. LED, (must be ordered separately); concealed manual override Standard Designation (type) Techn. data
Order number (manufacturer) Data sheet
3WE6A6X/EG24N9K4
R900 561 180
23 178
3WE6B6X/EG24N9K4
R900 561 270
4WE6C6X/EG24N9K4
R900 561 272
4WE6D6X/EG24N9K4
R900 561 274
4WE6D6X/OFEG24N9K4
R900 567 512
4WE6E6X/EG24N9K4
R900 561 278
4WE6G6X/EG24N9K4
R900 561 282
4WE6H6X/EG24N9K4
R900 561 286
4WE6HA6X/EG24N9K4
R900 549 534
4WE6J6X/EG24N9K4
R900 561 288
4WE6M6X/EG24N9K4
R900 577 475
4WE6Q6X/EG24N9K4
R900 561 292
4WE6U6X/EG24N9K4
R900 572 785
4WE6Y6X/EG24N9K4
R900 561 276
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 18 of 59
3.2.1.1.2.1 Smoothly switching
Designation (type) Techn. data Order number (manufacturer) Data sheet
4WE6D73-6X/EG24N9K4/A12
R900 546 257
23 178
4WE6D73-6X/OFEG24N9K4/A12
R900 567 066
4WE6E73-6X/EG24N9K4/A12
R900 567 095
4WE6G73-6X/EG24N9K4/A12
R900 572 783
4WE6H73-6X/EG24N9K4/A12
R900 906 660
4WE6J73-6X/EG24N9K4/A12
R900 567 997
4WE6U73-6X/EG24N9K4/A12
R900 977 181
4WE6W73-6X/EG24N9K4/A12
R900 567 269
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 19 of 59
3.2.1.1.3 Size 10 – with reduced electric power consumption (8 Watts) NOTE: Place notice on mounting plate. DC24V; circular plug-in connector M12x1 according to IEC 61076-2-101 w. LED; concealed manual override Size 10 directional valves are available as pilot operated valves. "SO803“ (Pilot valve with reduced electric power consumption – 8 Watts)
3.2.1.1.4 Size 10 with standard solenoid (30 Watts) and cubic connector May only be used after approval by the responsible technical department of the final customer! DC24V; plug-in connector design A according to EN175301-803 w. LED (must be ordered separately); concealed manual override
3.2.1.1.4.1 Standard
Designation (type) Techn. data Order number (manufacturer) Data sheet
3WE10A3X/OFCG24N9K4
Upon request
23 327
4WE10D3X/CG24N9K4
R900 589 933
4WE10D3X/OFCG24N9K4
R900 591 664
4WE10E3X/CG24N9K4
R900 588 201
4WE10HA3X/CG24N9K4
R900 598 662
4WE10J3X/CG24N9K4
R900 589 988
4WE10Q3X/CG24N9K4
R900 591 325
3.2.1.1.4.2 Smoothly switching
Designation (type) Techn. data Order number (manufacturer) Data sheet
4WE10D73-3X/CG24N9K4/A12
R900 528 033
23 183
4WE10D73-3X/OFCG24N9K4/A12
R900 563 418
4WE10E73-3X/CG24N9K4/A12
R900 563 418
4WE10H73-3X/CG24N9K4/A12
R900 912 742
4WE10J73-3X/CG24N9K4/A12
R900 560 858
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 20 of 59
3.2.1.2 Spool valves – pilot operated
Directional valves of the sizes 10 / 16 / 25 / 32 are also available as pilot operated valves. "SO803“ (Pilot valve with reduced electric power consumption – 8 Watts)
3.2.1.2.1 Size 10 – with standard solenoid (30 Watts) and cubic connector
May only be used after approval by the responsible technical department of the final customer! DC24V; plug-in connector design A according to EN175301-803 w. LED, (must be ordered separately); concealed manual override Designation (type) Techn. data
Order number (manufacturer) Data sheet
4WEH10E4X/6EG24N9K4
R900 928 168
24 751 4WEH10Q4X/6EG24N9ETS2K4
R900 710 131
4WEH10Q4X/6EG24N9K4
R900 924 732
3.2.1.2.2 Size 16 (pmax 280 bar) – with standard solenoid (30 Watts) and cubic connector
May only be used after approval by the responsible technical department of the final customer! DC24V; plug-in connector design A according to EN175301-803 w. LED, (must be ordered separately); concealed manual override Designation (type) Techn. data
Order number (manufacturer) Data sheet
4WEH16D7X/6EG24N9ETK4/B10
R900 924 874
24 751
4WEH16HD7X/OF6EG24N9ETK4/B10
R900 966 327
4WEH16E7X/6EG24N9ETK4/B10
R900 923 971
4WEH16J7X/6EG24N9ETK4/B10
R900 930 431
4WEH16Q7X/6EG24N9K4
R900 924 733
3.2.1.2.3 Size 22/25 – with standard solenoid (30 Watts) and cubic connector
May only be used after approval by the responsible technical department of the final customer! DC24V; plug-in connector design A according to EN175301-803 w. LED, (must be ordered separately); concealed manual override
4WEH22R7X/6EG24N9ES2K4/B10
R900 956 553
24 751
H-WEH25D6X/6EG24N9ETK4/B10D3
Upon request
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 21 of 59
3.2.1.2.4 Size 32 – with standard solenoid (30 Watts) and cubic connector
May only be used after approval by the responsible technical department of the final customer! DC24V; plug-in connector design A according to EN175301-803 w. LED, (must be ordered separately); concealed manual override
4WEH32R6X/6EG24N9ES2K4/B10
R900 976 198 24 751
3.2.1.3 Size 6 seat valves – with standard solenoid (30 Watts) and cubic connector
leak-free – operating pressure up to 350 bar, May only be used after approval by the responsible technical department of the final customer! DC24V; plug-in connector design A according to EN175301-803 w. LED, (must be ordered separately); concealed manual override
M-3SED6CK1X/350CG24N9K4
R900 052 392
22 049
M-3SED6UK1X/350CG24N9K4/B18
R900 224 607
3.2.2 Isolator valves
3.2.2.1 Check valves 3.2.2.1.1 Inline valves
Designation (type) Techn. data Order number (manufacturer) Data sheet
S6A1.0/ up to 315 bar; up to 18 l/min; 1 bar spring R900 422 881
20 375
S8A1.0/ up to 315 bar; up to 36 l/min; 1 bar spring R900 422 886
S10A1.0/ up to 315 bar; up to 60 l/min; 1 bar spring R900 420 531
S15A0.0/ up to 315 bar; up to 150 l/min; without spring R900 420 536
S15A1.0/ up to 315 bar; up to 150 l/min; 1 bar spring R900 420 537
S15A5.0/ up to 315 bar; up to 150 l/min; 5 bar spring R900 446 477
S20A1.0/ up to 315 bar; up to 180 l/min; 1 bar spring R900 420 525
S20A5.0/ up to 315 bar; up to 180 l/min; 5 bar spring R900 446 369
S25A1.0/ up to 315 bar; up to 350 l/min; 1 bar spring R900 420 511
S30A1.0/ up to 315 bar; up to 450 l/min; 1 bar spring R900 420 519
S30A5.0/ up to 315 bar; up to 450 l/min; 5 bar spring R900 446 709
3.2.2.1.2 Subplate mounted valves
Designation (type) Techn. data Order number (manufacturer) Data sheet
SL10GA1-4X/ up to 315 bar; up to 150 l/min; with pre-opening + leakage oil connection R900 483 370
21 468
SL10GB1-4X/100 up to 315 bar; up to 150 l/min; without pre-opening + leakage oil connection R900 451 135
SL20GA1-4X/ up to 315 bar; up to 350 l/min; with pre-opening + leakage oil connection R900 587 554
SL30GA1-4X/ up to 315 bar; up to 550 l/min; with pre-opening + leakage oil connection R900 587 556
SV10GA1-4X/ up to 315 bar; up to 150 l/min; with pre-opening R900 483 368
SV20GA1-4X/ up to 315 bar; up to 350 l/min; with pre-opening R900 587 550
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 22 of 59
3.2.2.1.3 Sandwich plate valves
3.2.2.1.3.1 Size 6
Designation (type) Techn. data Order number (manufacturer) Data sheet
Z1S6F05-4X/N up to 315 bar; up to 40 l/min; check valve in P+T; spring 0.5 bar: Upon request
21 534
Z1S6F30-4X/N up to 315 bar; up to 40 l/min; check valve in P+T; spring 3 bar: Upon request
Z1S6P05-4X/N up to 315 bar; up to 40 l/min; check valve in P; spring 0.5 bar: R901 152 381
Z1S6P30-4X/N up to 315 bar; up to 40 l/min; check valve in P; spring 3 bar: Upon request
Z1S6T05-4X/N up to 315 bar; up to 40 l/min; check valve in T; spring 0.5 bar: R901 312 739
Z1S6T30-4X/N up to 315 bar; up to 40 l/min; check valve in T; spring 3 bar: R901 152 370
Z2S6-1-6X/ up to 315 bar; up to 60 l/min; in channels A+B; spring 1.5 bar R900 347 495
21 548 Z2S6A1-6X/ up to 315 bar; up to 60 l/min; in channel A; spring 1.5 bar R900 347 498
Z2S6B1-6X/ up to 315 bar; up to 60 l/min; in channel B; spring 1.5 bar R900 347 501
3.2.2.1.3.2 Size 10
Designation (type) Techn. data Order number (manufacturer) Data sheet
Z1S10P05-1-4X/N up to 315 bar; up to 100 l/min; check valve in P; spring 0.5 bar: R901 285 818
21 537 Z1S10P30-1-4X/N up to 315 bar; up to 100 l/min; check valve in
P; spring 3 bar: Upon request
Z1S10TA05-2TB9-4X/N up to 315 bar; up to 100 l/min; check valve in T; spring 0.5 bar: R901 274 777
Z1S10TA30-2TB9-4X/N up to 315 bar; up to 100 l/min; check valve in T;spring 3 bar: Upon request
Z2S10-1-3X/ up to 315 bar; up to 120 l/min; in channels A+B; spring 1.5 bar R900 407 394
21 553 Z2S10A1-3X/ up to 315 bar; up to 120 l/min; in channel A; spring 1.5 bar R900 407 424
Z2S10B1-3X/ up to 315 bar; up to 120 l/min; in channel B; spring 1.5 bar R900 407 434
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 23 of 59
3.2.3 Pressure valves
3.2.3.1 Pressure relief valves 3.2.3.1.1 Direct operated
3.2.3.1.1.1 Subplate mounted valves Size 6
Designation (type) Techn. data Order number (manufacturer) Data sheet
DBDS6P1X/25 up to 25 bar; up to 50 l/min R900 429 411
25 402
DBDS6P1X/50 up to 50 bar; up to 50 l/min R900423 732 DBDS6P1X/100 up to 100 bar; up to 50 l/min R900 423 728 DBDS6P1X/200 up to 200 bar; up to 50 l/min R900 423 729 DBDA6P1X/25 up to 25 bar; up to 50 l/min R900 432 567 DBDA6P1X/50 up to 50 bar; up to 50 l/min R900 428 300 DBDA6P1X/100 up to 100 bar; up to 50 l/min R900 425 084 DBDA6P1X/200 up to 200 bar; up to 50 l/min R900 430 459
Size 10
Designation (type) Techn. data Order number (manufacturer) Data sheet
DBDS10P1X/25 up to 25 bar; up to 120 l/min R900 426 905
25 402
DBDS10P1X/50 up to 50 bar; up to 120 l/min R900 425 661 DBDS10P1X/100 up to 100 bar; up to 120 l/min R900 424 155 DBDS10P1X/200 up to 200 bar; up to 120 l/min R900 424 157 DBDA10P1X/25 up to 25 bar; up to 120 l/min R900 431 570 DBDA10P1X/50 up to 50 bar; up to 120 l/min R900 428 389 DBDA10P1X/100 up to 100 bar; up to 120 l/min R900 423 867 DBDA10P1X/200 up to 200 bar; up to 120 l/min R900 425 968 Size 20
Designation (type) Techn. data Order number (manufacturer) Data sheet
DBDS20P1X/25 up to 25 bar; up to 250 l/min R900 430 311
25 402
DBDS20P1X/50 up to 50 bar; up to 250 l/min R900 424 272 DBDS20P1X/100 up to 100 bar; up to 250 l/min R900 424 274 DBDS20P1X/200 up to 200 bar; up to 250 l/min R900 424 277 DBDA20P1X/25 up to 25 bar; up to 250 l/min R900 432 406 DBDA20P1X/50 up to 50 bar; up to 250 l/min R900 433 349 DBDA20P1X/100 up to 100 bar; up to 250 l/min R900 460 259 DBDA20P1X/200 up to 200 bar; up to 250 l/min R900 469 245
3.2.3.1.1.2 Screw-in cartridge valves Size 6
Designation (type) Techn. data Order number (manufacturer) Data sheet
DBDS6K1X/50 up to 50 bar; up to 50 l/min; R900 423 727
25 402
DBDS6K1X/100 up to 100 bar; up to 50 l/min; R900 423 723 DBDS6K1X/200 up to 200 bar; up to 50 l/min; R900 423 724 DBDS6K1X/315 up to 315 bar; up to 50 l/min; R900 423 725 DBDA6K1X/50 up to 50 bar; up to 50 l/min; R900 425 083 DBDA6K1X/100 up to 100 bar; up to 50 l/min; R900 425 080 DBDA6K1X/200 up to 200 bar; up to 50 l/min; R900 425 081 DBDA6K1X/315 up to 315 bar; up to 50 l/min; R900 425 082
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 24 of 59
Size 10 Designation (type) Techn. data
Order number (manufacturer) Data sheet
DBDS10K1X/50 up to 50 bar; up to 120 l/min; R900 424 153
25 402
DBDS10K1X/100 up to 100 bar; up to 120 l/min; R900 424 147 DBDS10K1X/200 up to 200 bar; up to 120 l/min; R900 424 149 DBDS10K1X/315 up to 315 bar; up to 120 l/min; R900 424 150 DBDA10K1X/50 up to 50 bar; up to 120 l/min; R900 425 966 DBDA10K1X/100 up to 100 bar; up to 120 l/min; R900 425 161 DBDA10K1X/200 up to 200 bar; up to 120 l/min; R900 425 162 Size 20
Designation (type) Techn. data Order number (manufacturer) Data sheet
DBDS20K1X/50 up to 50 bar; up to 250 l/min; R900 424 205
25 402
DBDS20K1X/100 up to 100 bar; up to 250 l/min; R900 424 267 DBDS20K1X/200 up to 200 bar; up to 250 l/min; R900 423 269 DBDS20K1X/315 up to 315 bar; up to 250 l/min; R900 424 271 DBDA20K1X/50 up to 50 bar; up to 250 l/min; R900 423 873 DBDA20K1X/100 up to 100 bar; up to 250 l/min; R900 423 871 DBDA20K1X/200 up to 200 bar; up to 250 l/min; R900 430 334 DBDA20K1X/315 up to 315 bar; up to 250 l/min; R900 423 872
3.2.3.1.1.3 Valves for threaded connection Size 6
Designation (type) Techn. data Order number (manufacturer) Data sheet
DBDS6G1X/50 up to 50 bar; up to 50 l/min; R900 423 722
25 402
DBDS6G1X/100 up to 100 bar; up to 50 l/min; R900 423 717 DBDS6G1X/200 up to 200 bar; up to 50 l/min; R900 423 719 DBDS6G1X/315 up to 315 bar; up to 50 l/min; R900 423 720 DBDA6G1X/50 up to 50 bar; up to 50 l/min; R900 424 177 DBDA6G1X/100 up to 100 bar; up to 50 l/min; R900 425 076 DBDA6G1X/200 up to 200 bar; up to 50 l/min; R900 426 477 DBDA6G1X/315 up to 315 bar; up to 50 l/min; R900 426 478 Size 10
Designation (type) Techn. data Order number (manufacturer) Data sheet
DBDS10G1X/50 up to 50 bar; up to 120 l/min; R900 424 745
25 402
DBDS10G1X/100 up to 100 bar; up to 120 l/min; R900 424 738 DBDS10G1X/200 up to 200 bar; up to 120 l/min; R900 424 140 DBDS10G1X/315 up to 315 bar; up to 120 l/min; R900 424 742 DBDA10G1X/50 up to 50 bar; up to 120 l/min; R900 425 160 DBDA10G1X/100 up to 100 bar; up to 120 l/min; R900 456 860 DBDA10G1X/200 up to 200 bar; up to 120 l/min; R900 423 866 DBDA10G1X/315 up to 315 bar; up to 120 l/min; R900 424 176 Size 20
Designation (type) Techn. data Order number (manufacturer) Data sheet
DBDS20G1X/50 up to 50 bar; up to 250 l/min; R900 424 276
25 402
DBDS20G1X/100 up to 100 bar; up to 250 l/min; R900 424 170 DBDS20G1X/200 up to 200 bar; up to 250 l/min; R900 424 172 DBDA20G1X/50 up to 50 bar; up to 250 l/min; R900 423 870 DBDA20G1X/100 up to 100 bar; up to 250 l/min; R900 436 044 DBDA20G1X/200 up to 200 bar; up to 250 l/min; R900 438 012
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 25 of 59
3.2.3.1.1.4 Sandwich plate valves Size 6
Designation (type) Techn. data Order number (manufacturer) Data sheet
ZDB6VA2-4X/50 up to 50 bar; up to 60 l/min; in channel A R900 431 678
25 751
ZDB6VB2-4X/50 up to 50 bar; up to 60 l/min; in channel B R900 430 645 ZDB6VP2-4X/50 up to 50 bar; up to 60 l/min; in channel P R900 432 804 ZDB6VA2-4X/100 up to 100 bar; up to 60 l/min; in channel A R900 437 441 ZDB6VB2-4X/100 up to 100 bar; up to 60 l/min; in channel B R900 431 401 ZDB6VP2-4X/100 up to 100 bar; up to 60 l/min; in channel P R900 423 274 ZDB6VA2-4X/200 up to 200 bar; up to 60 l/min; in channel A R900 426 329 ZDB6VB2-4X/200 up to 200 bar; up to 60 l/min; in channel B R900 429 509 ZDB6VP2-4X/200 up to 200 bar; up to 60 l/min; in channel P R900 428 339 HSZ06A100-3X/S025M00 Sandwich plate with pressure relief function P->T R900 936 130 48 050 ZDB6VA3-4X/50 up to 50 bar; up to 60 l/min; in channel A R900 425 683
25 751
ZDB6VB3-4X/50 up to 50 bar; up to 60 l/min; in channel B R900 438 971 ZDB6VP3-4X/50 up to 50 bar; up to 60 l/min; in channel P R900 432 112 ZDB6VA3-4X/100 up to 100 bar; up to 60 l/min; in channel A R900 428 435 ZDB6VB3-4X/100 up to 100 bar; up to 60 l/min; in channel B R900 431 167 ZDB6VP3-4X/100 up to 100 bar; up to 60 l/min; in channel P R900 460 711 ZDB6VA3-4X/200 up to 200 bar; up to 60 l/min; in channel A R900 438 967 ZDB6VB3-4X/200 up to 200 bar; up to 60 l/min; in channel B R900 465 884 ZDB6VP3-4X/200 up to 200 bar; up to 60 l/min; in channel P R900 422 089 Size 10 ZDB10VA2-4X/50 up to 50 bar; up to 100 l/min; in channel A R900 432 106
25 761
ZDB10VB2-4X/50 up to 50 bar; up to 100 l/min; in channel B R900 967 525 ZDB10VP2-4X/50 up to 50 bar; up to 100 l/min; in channel P R900 440 098 ZDB10VA2-4X/100 up to 100 bar; up to 100 l/min; in channel A R900 427 434 ZDB10VB2-4X/100 up to 100 bar; up to 100 l/min; in channel B R900 422 073 ZDB10VP2-4X/100 up to 100 bar; up to 100 l/min; in channel P R900 431 065 ZDB10VA2-4X/200 up to 200 bar; up to 100 l/min; in channel A R900 421 265 ZDB10VB2-4X/200 up to 200 bar; up to 100 l/min; in channel B R900 422 261 ZDB10VP2-4X/200 up to 200 bar; up to 100 l/min; in channel P R900 428 468 HSZ10A100-3X/M00 Sandwich plate with pressure relief function P->T R900 526 220 48 052 ZDB10VA3-4X/50 up to 50 bar; up to 100 l/min; in channel A R900 425 958
25 761
ZDB10VB3-4X/50 up to 50 bar; up to 100 l/min; in channel B Upon request ZDB10VP3-4X/50 up to 50 bar; up to 100 l/min; in channel P R900 460 358 ZDB10VA3-4X/100 up to 100 bar; up to 100 l/min; in channel A R900 906 981 ZDB10VB3-4X/100 up to 100 bar; up to 100 l/min; in channel B R900 580 968 ZDB10VP3-4X/100 up to 100 bar; up to 100 l/min; in channel P R900 522 880 ZDB10VA3-4X/200 up to 200 bar; up to 100 l/min; in channel A R900 449 071 ZDB10VB3-4X/200 up to 200 bar; up to 100 l/min; in channel B Upon request ZDB10VP3-4X/200 up to 200 bar; up to 100 l/min; in channel P R900 439 335 3.2.3.1.2 Pilot operated
3.2.3.1.2.1 Subplate mounted valves Size 20
Designation (type) Techn. data Order number (manufacturer) Data sheet
DB20-2-5X/200XY up to 200 bar; up to 500 l/min; R900 500 218
25 802 DB20-2-5X/50 up to 50 bar; up to 500 l/min; R900 597 212 DB30-2-5X/50 up to 50 bar; up to 650 l/min; R900 593 564 DB20-3-5X/200XY up to 200 bar; up to 500 l/min; R900 566 474 DB20-3-5X/50 up to 50 bar; up to 500 l/min; R900 502 708 Size 30
Designation (type) Techn. data Order number (manufacturer) Data sheet
DB30-3-5X/50 up to 50 bar; up to 650 l/min; R900 520 557 25 802
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 26 of 59
3.2.3.1.2.2 Screw-in cartridge valves Size 6
Designation (type) Techn. data Order number (manufacturer) Data sheet
DB6K2-4X/50Y up to 50 bar; up to 100 l/min; R900 425 998
25 731
DB6K2-4X/100Y up to 100 bar; up to 100 l/min; R900 408 060 DB6K2-4X/200Y up to 200 bar; up to 100 l/min; R900 422 238 DB6K3-4X/50Y up to 50 bar; up to 100 l/min; R900 424 557 DB6K3-4X/100Y up to 100 bar; up to 100 l/min; R900 426 666 DB6K3-4X/200Y up to 200 bar; up to 100 l/min; R900 424 552
Size 10 Designation (type) Techn. data
Order number (manufacturer) Data sheet
DB10K2-4X/50Y up to 50 bar; up to 100 l/min; R900 408 654
25 731 DB10K2-4X/100Y up to 100 bar; up to 100 l/min; R900 430 681 DB10K2-4X/200Y up to 200 bar; up to 100 l/min; R900 481 084 DB10K3-4X/50Y up to 50 bar; up to 100 l/min; R900 427 508 DB10K3-4X/100Y up to 100 bar; up to 100 l/min; R900 580 081 DB10K3-4X/200Y up to 200 bar; up to 100 l/min; R900 440 572
Size 20 Designation (type) Techn. data
Order number (manufacturer) Data sheet
DB20K2-1X/100XY up to 100 bar; up to 300 l/min; R900 470 297
25 818 DB20K2-1X/200XY up to 200 bar; up to 300 l/min; R900 470 298 DB20K3-1X/100XY up to 100 bar; up to 300 l/min; R900 402 736 DB20K3-1X/200XY up to 200 bar; up to 300 l/min; R900 493 310
3.2.3.1.2.3 Switchable – solenoid with reduced electric power consumption NOTE: Place notice on mounting plate. DC24V; circular plug-in connector M12x1 according to IEC 61076-2-101 w. LED; concealed manual override
Designation (type) Techn. data Order number (manufacturer) Data sheet
DBW10B2-5X/50-6EG24N9K72L SO803 up to 50 bar; up to 250 l/min; switchable Upon request 25 802 DBW10B3-5X/50-6EG24N9K72L SO803 up to 50 bar; up to 250 l/min; switchable Upon request
3.2.3.1.2.4 Switchable – with standard solenoid (30 Watts) May only be used after approval by the responsible technical department of the final customer! DC24V; plug-in connector design A according to EN175301-803 w. LED, (must be ordered separately); concealed manual override
Designation (type) Techn. data Order number (manufacturer) Data sheet
DBW10B2-5X/50-6EG24N9K4 up to 50 bar; up to 250 l/min; switchable R900 921 748 25 802 DBW10B3-5X/50-6EG24N9K4 up to 50 bar; up to 250 l/min; switchable R900 908 998 3.2.3.2 Pressure reducing valves 3.2.3.2.1 Direct operated 3.2.3.2.1.1 Subplate mounted valves Size 6
Designation (type) Techn. data Order number (manufacturer) Data sheet
DR6DP2-5X/25Y up to 25 bar; up to 60 l/min; with check v. R900 465 254
26 564
DR6DP2-5X/75YM up to 75 bar; up to 60 l/min; without check v. R900 450 964 DR6DP2-5X/75Y up to 75 bar; up to 60 l/min; with check v. R900 413 241 DR6DP2-5X/150Y up to 150 bar; up to 60 l/min; with check v. R900 413 242 DR6DP2-5X/210Y up to 210 bar; up to 60 l/min; with check v. R900 413 243 DR6DP3-5X/25Y up to 25 bar; up to 60 l/min; with check v. R900 479 794 DR6DP3-5X/75Y up to 75 bar; up to 60 l/min; with check v. R900 469 279 DR6DP3-5X/75YM up to 75 bar; up to 60 l/min; without check v. R900 472 420 DR6DP3-5X/150Y up to 150 bar; up to 60 l/min; with check v. R900 479 809 DR6DP3-5X/210Y up to 210 bar; up to 60 l/min; with check v. R900 478 697
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 27 of 59
Size 10
Designation (type) Techn. data Order number (manufacturer) Data sheet
DR10DP2-4X/75Y up to 75 bar; up to 80 l/min; with check v. R900 500 471
26 580 DR10DP2-4X/210Y up to 210 bar; up to 80 l/min; with check v. R900 594 125 DR10DP3-4X/75Y up to 75 bar; up to 80 l/min; with check v. R900 502 655 DR10DP3-4X/210Y up to 210 bar; up to 80 l/min; with check v. R900 500 903
3.2.3.2.1.2 Sandwich plate valves
Size 6
Designation (type) Techn. data Order number (manufacturer) Data sheet
ZDR6DA2-4X/25YM up to 25 bar; up to 50 l/min; in channel A; without check v. R900 448 079
26 570
ZDR6DA2-4X/25Y up to 25 bar; up to 50 l/min; in channel A; with check v. R900 410 808 ZDR6DA2-4X/75YM up to 75 bar; up to 50 l/min; in channel A; without check v. R900 410 815 ZDR6DA2-4X/75Y up to 75 bar; up to 50 l/min; in channel A; with check v. R900 410 813 ZDR6DA2-4X/150YM up to 150 bar; up to 80 l/min; in channel A; without check v. R900 445 958 ZDR6DA2-4X/150Y up to 150 bar; up to 50 l/min; in channel A; with check v. R900 410 849 ZDR6DA2-4X/210YM up to 210 bar; up to 50 l/min; in channel A; without check v. R900 423 213 ZDR6DA2-4X/210Y up to 210 bar; up to 50 l/min; in channel A; with check v. R900 410 855 ZDR6DB2-4X/25YM up to 25 bar; up to 50 l/min; in channel B; without check v. R900 449 839 ZDR6DB2-4X/75YM up to 75 bar; up to 50 l/min; in channel B; without check v. R900 431 771 ZDR6DB2-4X/150YM up to 150 bar; up to 50 l/min; in channel B; without check v. R900 431 172 ZDR6DB2-4X/210YM up to 210 bar; up to 50 l/min; in channel B; without check v. R900 463 269 ZDR6DP2-4X/25YM up to 25 bar; up to 50 l/min; in channel P; without check v. R900 483 785 ZDR6DP2-4X/75YM up to 75 bar; up to 50 l/min; in channel P; without check v. R900 483 786 ZDR6DP2-4X/150YM up to 150 bar; up to 50 l/min; in channel P; without check v. R900 483 787 ZDR6DP2-4X/210YM up to 210 bar; up to 50 l/min; in channel P; without check v. R900 483 788 ZDR6DA3-4X/25YM up to 25 bar; up to 50 l/min; in channel A; without check v. R900 455 586 ZDR6DA3-4X/25Y up to 25 bar; up to 50 l/min; in channel A; with check v. R900 448 490 ZDR6DA3-4X/75YM up to 75 bar; up to 50 l/min; in channel A; without check v. R900 421 983 ZDR6DA3-4X/75Y up to 75 bar; up to 50 l/min; in channel A; with check v. R900 410 864 ZDR6DA3-4X/150YM up to 150 bar; up to 80 l/min; in channel A; without check v. R900 477 431 ZDR6DA3-4X/150Y up to 150 bar; up to 50 l/min; in channel A; with check v. R900 445 998 ZDR6DA3-4X/210YM up to 210 bar; up to 50 l/min; in channel A; without check v. R900 479 783 ZDR6DA3-4X/210Y up to 210 bar; up to 50 l/min; in channel A; with check v. R900 424 371 ZDR6DB3-4X/25YM up to 25 bar; up to 50 l/min; in channel B; without check v. R900 425 957 ZDR6DB3-4X/75YM up to 75 bar; up to 50 l/min; in channel B; without check v. R900 432 119 ZDR6DB3-4X/150YM up to 150 bar; up to 50 l/min; in channel B; without check v. R900428 322 ZDR6DB3-4X/210YM up to 210 bar; up to 50 l/min; in channel B; without check v. R900 512 864 ZDR6DP3-4X/25YM up to 25 bar; up to 50 l/min; in channel P; without check v. R900 476 274 ZDR6DP3-4X/75YM up to 75 bar; up to 50 l/min; in channel P; without check v. R900 410 865 ZDR6DP3-4X/150YM up to 150 bar; up to 50 l/min; in channel P; without check v. R900 473 199 ZDR6DP3-4X/210YM up to 210 bar; up to 50 l/min; in channel P; without check v. R900 481 115
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 28 of 59
Size 10
Designation (type) Techn. data Order number (manufacturer) Data sheet
ZDR10DA2-5X/25YM up to 25 bar; up to 80 l/min; in channel A; without check v. R900 422 337
26 585
ZDR10DA2-5X/25Y up to 25 bar; up to 80 l/min; in channel A; with check v. R900 407 334 ZDR10DA2-5X/75YM up to 75 bar; up to 80 l/min; in channel A; without check v. R900 494 714 ZDR10DA2-5X/75Y up to 75 bar; up to 80 l/min; in channel A; with check v. R900 438 008 ZDR10DA2-5X/150YM up to 150 bar; up to 80 l/min; in channel A; without check v. R900 406 225 ZDR10DA2-5X/150Y up to 150 bar; up to 80 l/min; in channel A; with check v. R900 410 884 ZDR10DA2-5X/210YM up to 210 bar; up to 80 l/min; in channel A; without check v. R900 428 474 ZDR10DA5-5X/210Y up to 210 bar; up to 80 l/min; in channel A; with check v. R900 406 651 ZDR10DB2-5X/25YM up to 25 bar; up to 80 l/min; in channel B; without check v. R900 426 202 ZDR10DB2-5X/75YM up to 75 bar; up to 80 l/min; in channel B; without check v. R900 431 509 ZDR10DB2-5X/150YM up to 150 bar; up to 80 l/min; in channel B; without check v. R900 408 340 ZDR10DB2-5X/210YM up to 210 bar; up to 80 l/min; in channel B; without check v. R900 443 484 ZDR10DP2-5X/25YM up to 25 bar; up to 80 l/min; in channel P; without check v. R900 410 899 ZDR10DP2-5-5X/75YM up to 75 bar; up to 80 l/min; in channel P; without check v. R900 410 875 ZDR10DP2-5X/150YM up to 150 bar; up to 80 l/min; in channel P; without check v. R900 410 880 ZDR10DP2-5X/210YM up to 210 bar; up to 80 l/min; in channel P; without check v. R900 410 876 ZDR10DA3-5X/25YM up to 25 bar; up to 80 l/min; in channel A; without check v. R900 477 791 ZDR10DA3-5X/25Y up to 25 bar; up to 80 l/min; in channel A; with check valve R900 406 335 ZDR10DA3-5X/75YM up to 75 bar; up to 80 l/min; in channel A; without check v. R900 426 703 ZDR10DA3-5X/75Y up to 75 bar; up to 80 l/min; in channel A; with check v. R900 411 259 ZDR10DA3-5X/150YM up to 150 bar; up to 80 l/min; in channel A; without check v. R900 464 178 ZDR10DA3-5X/150Y up to 150 bar; up to 80 l/min; in channel A; with check v. R900 429 570 ZDR10DA3-5X/210YM up to 210 bar; up to 80 l/min; in channel A; without check v. R900 440 715 ZDR10DA3-5X/210Y up to 210 bar; up to 80 l/min; in channel A; with check v. R900 409 515 ZDR10DB3-5X/25YM up to 25 bar; up to 80 l/min; in channel B; without check v. R900 431 392 ZDR10DB3-5X/75YM up to 75 bar; up to 80 l/min; in channel B; without check v. R900 472 027 ZDR10DB3-5X/150YM up to 150 bar; up to 80 l/min; in channel B; without check v. R900 471 974 ZDR10DB3-5X/210YM up to 210 bar; up to 80 l/min; in channel B; without check v. R900 519 131 ZDR10DP3-5X/25YM up to 25 bar; up to 80 l/min; in channel P; without check v. R900 481 806 ZDR10DP3-5X/75YM up to 75 bar; up to 80 l/min; in channel P; without check v. R900 411 255 ZDR10DP3-5X/150YM up to 150 bar; up to 80 l/min; in channel P; without check v. R900 493 965 ZDR10DP3-5X/210YM up to 210 bar; up to 80 l/min; in channel P; without check v. R900 401 090 3.2.3.2.2 Pilot operated Size 10
Designation (type) Techn. data Order number (manufacturer) Data sheet
DR10-5-5X/50YM up to 50 bar; up to 150 l/min; without check v. R900 598 359
26 892 DR10-5-5X/200YM up to 200 bar; up to 150 l/min; without check v. R900 598 358 DR10-6-5X/50YM up to 50 bar; up to 150 l/min; without check v. R900 501 378 DR10-6-5X/200YM up to 200 bar; up to 150 l/min; without check v. R900 506 981 Size 20
Designation (type) Techn. data Order number (manufacturer) Data sheet
DR20-5-5X/200YM up to 200 bar; up to 300 l/min; without check v. R900 597 233 26 892 DR20-6-5X/200YM up to 200 bar; up to 300 l/min; without check v. R900 599 017
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 29 of 59
3.2.3.2.3 Pressure sequencing valves Size 6
Designation (type) Techn. data Order number (manufacturer) Data sheet
DZ6DP2-5X/75YM up to 75 bar; up to 60 l/min; without check valve R900 485 007
26 076
DZ6DP2-5X/150YM up to 150 bar; up to 60 l/min; without check valve R900 407 721 DZ6DP2-5X/210YM up to 210 bar; up to 60 l/min; without check valve R900 481 316 DZ6DP3-5X/75YM up to 75 bar; up to 60 l/min; without check valve R900 478 933 DZ6DP3-5X/150YM up to 150 bar; up to 60 l/min; without check valve R900 400 921 DZ6DP3-5X/210YM up to 210 bar; up to 60 l/min; without check valve R900 525 378 Size 10
Designation (type) Techn. data Order number (manufacturer) Data sheet
DZ10DP2-4X/75YM up to 75 bar; up to 80 l/min; without check valve R900 500 987
26 099
DZ10DP2-4X/150YM up to 150 bar; up to 80 l/min; without check valve R900 505 068 DZ10DP2-4X/210Y up to 210 bar; up to 80 l/min; with check valve R900 599 686 DZ10DP3-4X/75YM up to 75 bar; up to 80 l/min; without check valve R900 501 591 DZ10DP3-4X/150YM up to 150 bar; up to 80 l/min; without check valve R900 503 118 DZ10DP3-4X/210Y up to 210 bar; up to 80 l/min; with check valve R900 956 907
3.2.4 Flow control valves
3.2.4.1 Throttle valves 3.2.4.1.1 Pipe fitting
Designation (type) Techn. data Order number (manufacturer) Data sheet
MG6G1X/ up to 315 bar; up to 15 l/min; G1/4; Upon request
27 219
MG8G1X/ up to 315 bar; up to 30 l/min; G3/8; Upon request MG10G1X/ up to 315 bar; up to 50 l/min; G1/2; Upon request MG15G1X/ up to 315 bar; up to 125 l/min; G3/4; R9001 255 443 MG20G1X/ up to 315 bar; up to 200 l/min; G1; Upon request MG25G1X/ up to 315 bar; up to 300 l/min; G1 1/4; Upon request MG30G1X/ up to 315 bar; up to 400 l/min; G1 1/2; R901 196 137 3.2.4.2 Throttle check valves 3.2.4.2.1 Pipe fitting
Designation (type) Techn. data Order number (manufacturer) Data sheet
MK6G1X/ up to 315 bar; up to 15 l/min; G1/4; Upon request
27 219
MK8G1X/ up to 315 bar; up to 30 l/min; G3/8; Upon request MK10G1X/ up to 315 bar; up to 50 l/min; G1/2; Upon request MK15G1X/ up to 315 bar; up to 125 l/min; G3/4; Upon request MK20G1X/ up to 315 bar; up to 200 l/min; G1; Upon request MK25G1X/ up to 315 bar; up to 300 l/min; G1 1/4; Upon request MK30G1X/ up to 315 bar; up to 400 l/min; G1 1/2; Upon request DRV-06-1-1X/ up to 350 bar; up to 20 l/min; G1/8; Upon request
32 502
DRV-08-1-1X/ up to 350 bar; up to 50 l/min; G1/4; Upon request DRV-10-1-1X/ up to 350 bar; up to 60 l/min; G3/8; Upon request DRV-12-1-1X/ up to 350 bar; up to 90 l/min; G1/2; Upon request DRV-16-1-1X/ up to 350 bar; up to 180 l/min; G3/4; Upon request DRV-20-1-1X/ up to 350 bar; up to 300 l/min; G1; Upon request
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 30 of 59
3.2.4.2.2 Sandwich plate valves Size 6
Designation (type) Techn. data Order number (manufacturer) Data sheet
Z2FS6A2-4X/2Q up to 315 bar; up to 80 l/min; in channel A; discharge throttle. R900 427 254
27 506
Z2FS6B2-4X/2Q up to 315 bar; up to 80 l/min; in channel B; discharge throttle. R900 423 224
Z2FS6-2-4X/2Q up to 315 bar; up to 80 l/min; in channel A+B R900 481 622
Z2FS6A3-4X/2Q up to 315 bar; up to 80 l/min; in channel A; discharge throttle. Upon request
Z2FS6B3-4X/2Q up to 315 bar; up to 80 l/min; in channel B; discharge throttle. Upon request
Z2FS6-3-4X/2Q up to 315 bar; up to 80 l/min; in channel A+B R900 434 395 Sizes 10 and 16
Designation (type) Techn. data Order number (manufacturer) Data sheet
Z2FS10-5-3X/ up to 315 bar; up to 160 l/min; in channel A+B R900 989 095
27 518 Z2FS10A5-3X/S2 up to 315 bar; up to 160 l/min; in channel A; discharge
throttle. R900 571 890
Z2FS10B5-3X/S2 up to 315 bar; up to 160 l/min; in channel B; discharge throttle. R900 989 106
Z2FS16-3X/S2 up to 350 bar; up to 250 l/min; in channel A+B R900 457 256
3.2.4.3 Flow control valves 3.2.4.3.1 Subplate mounted valves Size 6
Designation (type) Techn. data Order number (manufacturer) Data sheet
2FRM6B36-3X/1,5QM up to 315 bar; up to 1.5 l/min; without check valve Upon request
28 163
2FRM6B36-3X/1,5QR up to 315 bar; up to 1.5 l/min; with check valve Upon request 2FRM6B36-3X/3QM up to 315 bar; up to 3 l/min; without check valve Upon request 2FRM6B36-3X/3QR up to 315 bar; up to 3 l/min; with check valve Upon request 2FRM6B36-3X/6QM up to 315 bar; up to 6 l/min; without check valve Upon request 2FRM6B36-3X/6QR up to 315 bar; up to 6 l/min; with check valve Upon request Size 10
Designation (type) Techn. data Order number (manufacturer) Data sheet
2FRM10-3X/25LB up to 315 bar; up to 25 l/min; R900 423 256 28 389 2FRM10-3X/50LB up to 315 bar; up to 50 l/min; R900 423 261 3.2.4.3.2 Sandwich plate valves
Designation (type) Techn. data Order number (manufacturer) Data sheet
Z2FRM6AB2-2X/6QR up to 315 bar, up to 6 l/min, in channel A, with check valve Upon request
28 164
Z2FRM6AB2-2X/32QR up to 315 bar, up to 32 l/min, in channel A, with check valve Upon request Z2FRM6BB2-2X/6QR up to 315 bar, up to 6 l/min, in channel B, with check valve Upon request Z2FRM6BB2-2X/32QR up to 315 bar, up to 32 l/min, in channel B, with check valve Upon request Z2FRM6CB2-2X/6QR up to 315 bar, up to 6 l/min, in channel A+B, with check v. Upon request Z2FRM6CB2-2X/32QR up to 315 bar, up to 32 l/min, in channel A+B, with check valve Upon request Z2FRM6TB2-2X/6QR up to 315 bar, up to 6 l/min, in channel T, with check valve Upon request Z2FRM6TB2-2X/32QR up to 315 bar, up to 32 l/min, in channel T, with check valve Upon request
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 31 of 59
3.2.4.3.3 Screw-in cartridge valves Size 6
Designation (type) Techn. data Order number (manufacturer) Data sheet
2FRM6K2-1X/6QR up to 315 bar; up to 6 l/min; R901 249 167 28 155 2FRM6K2-1X/32QR up to 315 bar; up to 32 l/min; Upon request Size 10
Designation (type) Techn. data Order number (manufacturer) Data sheet
2FRM10K2-1X/60QR up to 315 bar; up to 60 l/min; Upon request 28 155
3.3 Cylinders
3.3.1 Tie rod cylinders
Piston rod with square, with drain port if required Designation (type) Techn. data
Order number (manufacturer) Data sheet
CDT3....F1X/...H…E…B… 160 bar; Pistons 25-200 mm; rods 12-140 mm XXXX XXX XXX
17 039 CGT3....F1X/...H…E…B… 160 bar;
Pistons 25-200 mm; rods 12-140 mm XXXX XXX XXX
H = Piston rod hardened and hard chromium-plated E = End position cushioning adjustable on both sides B = with leakage oil connection (only for concealed cylinders)
3.4 Accessories
3.4.1 Adapter and cover plates
3.4.1.1 Adapter for mating connector Designation (type) Techn. data
Order number (manufacturer) Data sheet
Adapter K4 on M12x1 For ABZSS..E (electr. operated accumulator discharging)
R901 034 223 ---
3.4.1.2 Cover plates
Designation (type) Techn. data Order number (manufacturer) Data sheet
HSA06A077-3X/G24K4M01/J31 up to 315 bar; as cover plate with porting pattern A06 R900 968 382 ---
HSA06A064-3X/M00 Cover plate with pressure relief function P-T R900 579 914 ---
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 32 of 59
4 Data sheets
4.1 Small power units
4.1.1 ABSKG-40AL9/VGF2-006/90L/1NT/VW-PT Order no. R901 339 394
consisting of:
T pos Denomination Type Order no.
0.10 Tank ABZBR- 40/09-B 1 A/M R901 028 367
0.12 OIL LEVEL INDICATOR AB31-21/127T R900 013 663
0.14 BREATHER PI0125 SM-L/UM-OS R901 064 797
0.16 FLOAT SWITCH LK7022 L=264 R900 245 162
0.17 THERMOMETER TR7432+TT3050+E35030 R901 278 209
0.30 PUMP PGF2-2X/006RE01VE4 R900 932 265
0.33 EL. MOTOR MOT-EC-ET2-B5-90L-4-5CA-1,5-A3T-SIE R901 310 109
0.34 COUPLING AB33-22/KD 19-20/24-98 R900 325 768
0.35 BELL HOUSING AC PBR 80B-4H/ A200/110 -1X/DH-AL R900 025 974
0.50 HY PRESSURE CONTROL UNIT AB42-15/10-100AM1 R901 064 994
0.60 COUPLING PLUG MD-012-2-WR021-19-1 R900 034 668
0.61 DUST PROTECTION CAP MD-012-5-74 KU R900 030 420
0.62 ORIFICE 3.0 / 17.9 X 1.5 -ST R900 739 428
Side view drawn without
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 33 of 59
4.1.2 ABSKG-40AL9/VGF2-006/100L/1NT/VW-PT Order no. R901 339 393
consisting of:
T pos Denomination Type Order no.
0.10 Tank ABZBR- 40/09-B 1 A/M R901 028 367
0.12 OIL LEVEL INDICATOR AB31-21/127T R900 013 663
0.14 BREATHER PI0125 SM-L/UM-OS R901 064 797
0.16 FLOAT SWITCH LK7022 L=264 R900 245 162
0.17 THERMOMETER TR7432+TT3050+E35030 R901 278 209
0.30 PUMP PGF2-2X/006RE01VE4 R900 932 265
0.33 EL. MOTOR MOT-EC-ET2-B5-100L-4-5CA-3-A3T-SIE R901 309 954
0.34 COUPLING AB33-22/KD24-20/28-98 R900 325 769
0.35 BELL HOUSING AC PBR 80B-4H/ A250/124 -1X/DH-AL R900 025 980
0.50 HY PRESSURE CONTROL UNIT AB42-15/10-200AM1 R901 064 995
0.60 COUPLING PLUG MD-012-2-WR021-19-1 R900 034 668
0.61 DUST PROTECTION CAP MD-012-5-74 KU R900 030 420
0.62 ORIFICE 3.0 / 17.9 X 1.5 -ST R900 739 428
Side view drawn without
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 34 of 59
4.1.3 ABSKG-40AL9/VGF2-011/100L/1NT/VW-PT Order no. R901 339 392
consisting of:
T pos Denomination Type Order no.
0.10 Tank ABZBR- 40/09-B 1 A/M R901 028 367
0.12 OIL LEVEL INDICATOR AB31-21/127T R900 013 663
0.14 BREATHER PI0125 SM-L/UM-OS R901 064 797
0.16 FLOAT SWITCH LK7022 L=264 R900 245 162
0.17 THERMOMETER TR7432+TT3050+E35030 R901 278 209
0.30 PUMP PGF2-2X/011RE01VE4 R900 932 271
0.33 EL. MOTOR MOT-EC-ET2-B5-100L-4-5CA-3-A3T-SIE R901 309 954
0.34 COUPLING AB33-22/KD24-20/28-98 R900 325 769
0.35 BELL HOUSING AC PBR 80B-4H/ A250/124 -1X/DH-AL R900 025 980
0.50 HY PRESSURE CONTROL UNIT AB42-15/10-100AM1 R901 064 994
0.60 COUPLING PLUG MD-012-2-WR021-19-1 R900 034 668
0.61 DUST PROTECTION CAP MD-012-5-74 KU R900 030 420
0.62 ORIFICE 3.0 / 17.9 X 1.5 -ST R900 739 428
Side view drawn without
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 35 of 59
4.1.4 ABSKG-40AL9/VGF2-11/132M/1NT/VW-PT Order no. R901 339 391
consisting of:
T pos Denomination Type Order no.
0.10 Tank ABZBR- 40/09-B 1 A/M R901 028 367
0.12 OIL LEVEL INDICATOR AB31-21/127T R900 013 663
0.14 BREATHER PI0125 SM-L/UM-OS R901 064 797
0.16 FLOAT SWITCH LK7022 L=264 R900 245 162
0.17 THERMOMETER TR7432+TT3050+E35030 R901 278 209
0.30 PUMP PGF2-2X/011RE01VE4 R900 932 271
0.33 EL. MOTOR MOT-EC-ET2-B5-132S-4-5SF-5,5-A3T-SIE R901 341 837
0.34 COUPLING AB33-22/KD28-20/38 R900 541 507
0.35 BELL HOUSING AC PBR 80B-4H/ A300/144 -1X/DH-AL R900 025 987
0.50 HY PRESSURE CONTROL UNIT AB42-15/10-200AM1 R901 064 995
0.60 COUPLING PLUG MD-012-2-WR021-19-1 R900 034 668
0.61 DUST PROTECTION CAP MD-012-5-74 KU R900 030 420
0.62 ORIFICE 3.0 / 17.9 X 1.5 -ST R900 739 428
Side view drawn without
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 36 of 59
4.1.5 ABSKG-60AL9/VGF2-16/112M/1NT/VW-PT Order no. R901 339 390
consisting of:
T pos Denomination Type Order no.
0.10 Tank ABZBR- 60/09-B 1 A/M R901 029 093
0.12 OIL LEVEL INDICATOR AB31-21/127T R900 013 663
0.14 BREATHER PI0125 SM-L/UM-OS R901 064 797
0.16 FLOAT SWITCH LK7022 L=264 R900 245 162
0.17 THERMOMETER TR7432+TT3050+E35030 R901 278 209
0.30 PUMP PGF2-2X/016RE20VE4 R900 932 193
0.33 EL. MOTOR MOT-EC-ET2-B5-112M-4-5SF-4-A4T-SIE R901 309 846
0.34 COUPLING AB33-22/KD24-20/28-98 R900 325 769
0.35 BELL HOUSING AC PBR 80B-4H/ A250/124 -1X/DH-AL R900 025 980
0.50 HY PRESSURE CONTROL UNIT AB42-15/10-100AM1 R901 064 994
0.60 COUPLING PLUG MD-012-2-WR021-19-1 R900 034 668
0.61 DUST PROTECTION CAP MD-012-5-74 KU R900 030 420
0.62 ORIFICE 3.0 / 17.9 X 1.5 -ST R900 739 428
Side view drawn without
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 37 of 59
4.1.6 ABSKG-60AL9/VGF2-16/132M/1NT/VW-PT Order no. R901 339 389
consisting of:
T pos Denomination Type Order no.
0.10 Tank ABZBR- 60/09-B 1 A/M R901 029 093
0.12 OIL LEVEL INDICATOR AB31-21/127T R900 013 663
0.14 BREATHER PI0125 SM-L/UM-OS R901 064 797
0.16 FLOAT SWITCH LK7022 L=264 R900 245 162
0.17 THERMOMETER TR7432+TT3050+E35030 R901 278 209
0.30 PUMP PGF2-2X/016RE20VE4 R900 932 193
0.33 EL. MOTOR MOT-EC-ET2-B5-132M-4-5CB-7,5-A3T-SIE R901 304 948
0.34 COUPLING AB33-22/KD28-20/38 R900 541 507
0.35 BELL HOUSING AC PBR 80B-4H/ A300/144 -1X/DH-AL R900 025 987
0.50 HY PRESSURE CONTROL UNIT AB42-15/10-200AM1 R901 064 995
0.60 COUPLING PLUG MD-012-2-WR021-19-1 R900 034 668
0.61 DUST PROTECTION CAP MD-012-5-74 KU R900 030 420
0.62 ORIFICE 3.0 / 17.9 X 1.5 -ST R900 739 428
Side view drawn without
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 38 of 59
4.1.7 ABSKG-60AL9/HV7-10-4/100L/1NT/VW-PT Order no. R901 339 388
consisting of:
T pos Denomination Type Order no.
0.10 Tank ABZBR- 60/09-B 1 A/M R901 029 093
0.12 OIL LEVEL INDICATOR AB31-21/127T R900 013 663
0.14 BREATHER PI0125 SM-L/UM-OS R901 064 797
0.16 FLOAT SWITCH LK7022 L=264 R900 245 162
0.17 THERMOMETER TR7432+TT3050+E35030 R901 278 209
0.30 PUMP PV7-1X/10-14RE01MC3-16 R900 598753
0.33 EL. MOTOR MOT-EC-ET2-B5-100L-4-5CA-3-A3T-SIE R901 309 954
0.34 COUPLING AB33-22/KD24-20/28-98 R900 325 769
0.35 BELL HOUSING AC PBR 80B-4H/ A250/124 -1X/DH-AL R900 025 980
0.36 PUMP BASE AB33-33/PTFL 250 R900 025 968
0.40 HOSE AB23-14/2SN-16/XXX R900 273 465
0.41 CHECK VALVE RHD 18 PL0,5 R900 015 404
0.42 HOSE AB23-14/2SN-10/XXX R900 829 145
0.50 HY PRESSURE CONTROL UNIT AB42-15/10-050AM1 R901 064 993
0.60 COUPLING PLUG MD-012-2-WR021-19-1 R900 034 668
0.61 DUST PROTECTION CAP MD-012-5-74 KU R900 030 420
0.62 ORIFICE 3.0 / 17.9 X 1.5 -ST R900 739 428
Side view drawn without
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx Version 1.5.1 / Apr. 03, 2013 Page 39 of 59
4.1.8 ABSKG-60AL9/HV7-10-4/132S/1NT/VW-PT Order no.. R901 339 387
consisting of:
T pos Denomination Type Order no.
0.10 Tank ABZBR- 60/09-B 1 A/M R901 029 093
0.12 OIL LEVEL INDICATOR AB31-21/127T R900 013 663
0.14 BREATHER PI0125 SM-L/UM-OS R901 064 797
0.16 FLOAT SWITCH LK7022 L=264 R900 245 162
0.17 THERMOMETER TR7432+TT3050+E35030 R901 278 209
0.30 PUMP PV7-1X/10-14RE01MC3-16 R900 598753
0.33 EL. MOTOR MOT-EC-ET2-B5-132S-4-5SF-5,5-A3T-SIE R901 341 837
0.34 COUPLING AB33-22/KD28-20/38 R900 541 507
0.35 BELL HOUSING AC PBR 80B-4H/ A300/144 -1X/DH-AL R900 025 987
0.36 PUMP BASE AB33-33/PTFL 300 R900 025 969
0.40 HOSE AB: HOSE AB23-14/2SN-16/XXX R900 273 465
0.41 CHECK VALVE RHD 18 PL0,5 R900 015 404
0.42 HOSE AB: HOSE AB23-14/2SN-10/XXX R900 829 145
0.50 HY PRESSURE CONTROL UNIT AB42-15/10-200AM1 R901 064 995
0.60 COUPLING PLUG MD-012-2-WR021-19-1 R900 034 668
0.61 DUST PROTECTION CAP MD-012-5-74 KU R900 030 420
0.62 ORIFICE 3.0 / 17.9 X 1.5 -ST R900 739 428
Side view drawn without
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx HFC Version 1.5.1 / Apr. 03, 2013 Page 40 of 59
5 Systems with flame-resistant hydraulic fluids of the HFC group
General information on the use of HFC fluids
The characteristics of hydraulic fluids of the HFC group (water glycol, reference oil "Ultrasafe 620 VW Kassel") according to DIN EN ISO 12922 or VDMA 24317 differ from mineral oil in a few important aspects. When designing and manufacturing the hydraulic systems their particularities must be taken into account. • The optimum operating temperature is +40 °C.
The lower operating temperature must be taken into consideration with respect to the thermal efficiency. Operating temperatures above 60 °C are not admissible!
• The maximum admissible operating pressure is 210 bar. • The density of the HFC fluid is (at 15 °C) approximately 20 % greater than that of mineral oil.
Therefore, the suction lines must have greater dimensions. • The air release capacity of water glycol is significantly lower. This must be taken into account
when dimensioning the system in order to prevent cavitation and erosion. • To ensure a trouble-free operation of the hydraulic system, the fluid should be monitored
(according to the manufacturer's specifications). • Since the HFC hydraulic fluid has a lower dirt separation capacity than mineral oil it is crucial
that all solid and liquid foreign substances in this fluid are continuously monitored. Contamination with other fluids (including other HFC fluids) must be prevented in any case.
• It is to be ensured that the devices and pipelines of the hydraulic system do not run empty and
generate air cushions when the machine is at standstill. Extended standstill times are to be avoided.
• The following metal materials or their alloys must not be used: zinc, aluminum, cadmium,
magnesium. • The following non-metal materials are unsuitable:
FKM seals and materials based on polyurethane PU (Vulkollan or Hydrofit), polyamide (PA), asbestos and leather.
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx HFC Version 1.5.1 / Apr. 03, 2013 Page 41 of 59
5.1 Pump station with tank and accessories
5.1.1 Pumps
5.1.1.1 Fixed displacement pumps – internal gear pumps Designation (type) Techn. data
Order number (manufacturer) Data sheet
PGH4-2X/020RE11WE4 175 bar; 28.9 l/min with n=1450 (max) R901 180 578
10 223
PGH4-2X/032RE11WE4 175 bar; 46.9 l/min with n=1450 (max) R901 062 758 PGH5-2X/063RE11WE4 175 bar; 92.8 l/min with n=1450 (max) Upon request PGH5-2X/100RE11WE4 175 bar; 143.8 l/min with n=1450 (max) R901 023 782 PGH5-2X/125RE11WE4 175 bar; 179.8 l/min with n=1450 (max) R901 154 927 PGH5-2X/200RE07WE4 100 bar; 287.7 l/min with n=1450 (max) Upon request PGH5-2X/250RE07WE4 70 bar; 359.6 l/min with n=1450 (max) R900 721 268 5.1.1.2 Variable displacement pumps – axial piston pumps
min. pressure at suction port: > 1 bar absolute
Designation (type) Techn. data Order number (manufacturer) Data sheet
AE-A10VSO18DFR1/31R-PPA12N00 280 bar; 27 l/min with n=1450 R910 939 599
92 711
AE-A10VSO28DFR1/31R-PPA12N00 280 bar; 42 l/min with n=1450 R910 914 036 AE-A10VSO45DFR1/31R-PPA12N00 280 bar; 68 l/min with n=1450 R910 916 405 AE-A10VSO71DFR1/31R-PPA12N00 280 bar; 107 l/min with n=1450 R910 948 634 AE-A10VSO100DFR1/31R-PPA12N00 280 bar; 150 l/min with n=1450 R910 929 637 AE-A10VSO140DFR1/31R-PPA12N00 280 bar; 150 l/min with n=1450 max. Upon request AE-A10VSO28DFLR/31R-PPA12N00 Power controller specification required XXXX XXX XXX AE-A10VSO45DFLR/31R-PPA12N00 Power controller specification required XXXX XXX XXX AE-A10VSO71DFLR/31R-PPA12N00 Power controller specification required XXXX XXX XXX AE-A10VSO100DFLR/31R-PPA12N00 Power controller specification required XXXX XXX XXX AE-A10VSO140DFLR/31R-PPA12N00 Power controller specification required XXXX XXX XXX
5.1.2 Reservoir
5.1.2.1 Reservoir 100 to 1000 l (DIN-24339, type BN, cover type A) Stainless steel reservoirs – structural design according to AB10217 The following filling coupling is to be used:
MD-019-2-WR033-01-1 with dust protection cap MD-019-5-01-1 (stainless steel version)
5.1.3 Air Breather
Designation (type) Techn. data Order number (manufacturer) Data sheet
Air filter PI0125 SM-L/UM-OS Mounting 6 x M5, hole circle Ø 73 mm R901 064 797 see Mahle
5.1.4 Pressure measurement and indicating devices
Designation (type) Techn. data Order number (manufacturer) Data sheet
AB42-15/10-100AM1 Pressure control unit with pressure gauge R901 064 994
AB42-15 AB42-15/10-200AM1 Pressure control unit with pressure
gauge R900 827 581
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx HFC Version 1.5.1 / Apr. 03, 2013 Page 42 of 59
5.1.5 Filters
All filter types according to DIN 24550. If used and designed properly and according to the criteria below, the service life of the filter element is 6 months or 3000 operating hours. The installation of duplex switch filters may be necessary (according to works-specific instructions). Duplex filters must be approved by VW.
5.1.5.1 Clogging indicator - Electric maintenance indicator - 3 LED displays: green: pressure differential <75 % yellow: pressure differential> 75 % red: pressure differential = 100 %
Designation (type) Techn. data Order number (manufacturer) Data sheet
WE-2SP-M12x1 M12x1, 75 %, 100 % R928 028 410 51 450
5.1.5.2 Inline filter in return flow - Single filter with bypass (cracking pressure 3.5 bar) - Optical maintenance indicator with switching pressure 2.2 bar
5.1.5.2.1 Filter bowl can be unscrewed to the bottom: Standard pressure rating 250 bar
Designation (type) Max. flow for initial Δp≤ 0.5 bar
Oil cleanliness classes according to
ISO 4406
Order number (manufacturer) Data sheet
245LEN0100-H10XLA00-V2,2-M-R3 32 l/min 17 / 14 / 10 R928 018 984
51 421
245LEN0160-H10XLA00-V2,2- M-R6 68 l/min 17 / 14 / 10 R928 018 985 245LEN0250-H10XLA00-V2,2- M-R6 96 l/min 17 / 14 / 10 R928 018 986 245LEN0100-H3XLA00-V2,2- M-R3 16 l/min 13 / 10 / 8 R928 018 980 245LEN0160-H3XLA00-V2,2- M-R6 36 l/min 13 / 10 / 8 R928 018 982 245LEN0250-H3XLA00-V2,2- M-R6 56 l/min 13 / 10 / 8 R928 018 983
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx HFC Version 1.5.1 / Apr. 03, 2013 Page 43 of 59
5.1.5.2.2 Filter bowl can be unscrewed to the top: Standard pressure rating 100 bar
Designation (type) Max. flow for initial Δp≤ 0.5 bar
Oil cleanliness classes according to
ISO 4406
Order number (manufacturer) Data sheet
100 FLEN 0250 H10XL-A00-07V2.2-S0M00 96 l/min 17 / 14 / 10 R928 018 977
51 402
100 FLEN 0400 H10XL-A00-07V2.2-S0M00 108 l/min 17 / 14 / 10 R928 018 978 100 FLEN 0630 H10XL-A00-07V2.2-S0M00 414 l/min 17 / 14 / 10 R928 018 979 100 FLEN 1000 H10XL-A00-07V2.2-S0M00 464 l/min 17 / 14 / 10 R928 018 988 100 FLEN 0250 H3XL-A00-07V2.2-S0M00 56 l/min 13 / 10 / 8 R928 018 972 100 FLEN 0400 H3XL-A00-07V2.2-S0M00 68 l/min 13 / 10 / 8 R928 018 973 100 FLEN 0630 H3XL-A00-07V2.2-S0M00 184 l/min 13 / 10 / 8 R928 018 974 100 FLEN 1000 H3XL-A00-07V2.2-S0M00 207 l/min 13 / 10 / 8 R928 018 987 5.1.5.2.3 Filter bowl can be unscrewed to the top: Standard pressure rating 250 bar
Designation (type) Max. flow for initial Δp≤ 0.5 bar
Oil cleanliness classes according to
ISO 4406
Order number (manufacturer) Data sheet
445LEN0400-H10XLA00-V5,0-M-R6-V3-9 108 l/min 17 / 14 / 10 R928 051 526 51 423 445LEN0400-H3XLA00-V5,0-M-R6-V3-9 68 l/min 13 / 10 / 8 R928 0515 25 5.1.5.3 Inline filter in bypass circuit
- Single filter with bypass (cracking pressure 3.5 bar) - Optical maintenance indicator with switching pressure 2.2 bar
5.1.5.3.1 Filter bowl can be unscrewed to the bottom: Standard pressure rating 250 bar
Designation (type) Max. flow for initial Δp≤ 0.5 bar
Oil cleanliness classes according to
ISO 4406
Order number (manufacturer) Data sheet
245LEN0100-H3XLA00-V2,2- M-R3 20 l/min 13 / 10 / 8 R928 018 980 51 421 245LEN0160-H3XLA00-V2,2- M-R6 45 l/min 13 / 10 / 8 R928 018 982
245LEN0250-H3XLA00-V2,2- M-R6 70 l/min 13 / 10 / 8 R928 018 983 5.1.5.3.2 Filter bowl can be unscrewed to the top: Standard pressure rating 100 bar
Designation (type) Max. flow for initial Δp≤ 0.5 bar
Oil cleanliness classes according to
ISO 4406
Order number (manufacturer) Data sheet
100 FLEN 0250 H3XL-A00-07V2.2-S0M00 70 l/min 13 / 10 / 8 R928 018 972
51 402 100 FLEN 0400 H3XL-A00-07V2.2-S0M00 85 l/min 13 / 10 / 8 R928 018 973 100 FLEN 0630 H3XL-A00-07V2.2-S0M00 231 l/min 13 / 10 / 8 R928 018 974 100 FLEN 1000 H3XL-A00-07V2.2-S0M00 259 l/min 13 / 10 / 8 R928 018 987 5.1.5.3.3 Filter bowl can be unscrewed to the top: Standard pressure rating 250 bar
Designation (type) Max. flow for initial Δp≤ 0.5 bar
Oil cleanliness classes according to
ISO 4406
Order number (manufacturer) Data sheet
445LEN0400-H3XLA00-V5,0-M-R6-V3-9 85 l/min ISO 13/10/8 R928 051 525 51 423
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx HFC Version 1.5.1 / Apr. 03, 2013 Page 44 of 59
5.1.5.4 Inline filter in main flow - Single filter without bypass - Optical maintenance indicator with switching pressure 5 bar
5.1.5.4.1 Medium pressure standard pressure rating 250 bar
5.1.5.4.1.1 Filter bowl can be unscrewed to the bottom
Designation (type) Max. flow for initial Δp≤ 1 bar
Oil cleanliness classes according to
ISO 4406
Order number (manufacturer) Data sheet
245LEN0100-H10XLB00-V5.0--M-R3 44 l/min 17 / 14 / 10 R928 019 005
51 421
245LEN0160-H10XLB00-V5.0--M-R6 100 l/min 17 / 14 / 10 R928 019 006 245LEN0250-H10XLB00-V5.0--M-R6 144 l/min 17 / 14 / 10 R928 019 007 245LEN0100-H3XLB00-V5.0--M-R3 28 l/min 13 / 10 / 8 R928 019 002 245LEN0160-H3XLB00-V5.0--M-R6 56 l/min 13 / 10 / 8 R928 019 003 245LEN0250-H3XLB00-V5.0-M-R6 96 l/min 13 / 10 / 8 R928 019 004
5.1.5.4.1.2 Filter bowl can be unscrewed to the top -Maintenance indicator flanged to the side - Draining bore in the WO flange surface
Designation (type) Max. flow for initial Δp≤ 1 bar
Oil cleanliness classes according to
ISO 4406
Order number (manufacturer) Data sheet
445LEN0630-H3XLB00-V5,0-M-R8-V3-9 176 l/min 13 / 10 / 8 R928 051 524 51 423 445LEN0400-H3XLB00-V5,0-M-R6-V3-9 144 l/min 13 / 10 / 8 R928 051 523 5.1.5.4.2 High pressure standard pressure rating 400 bar
5.1.5.4.2.1 Filter bowl can be unscrewed to the bottom
Designation (type) Max. flow for initial Δp≤ 1 bar
Oil cleanliness classes according to
ISO 4406
Order number (manufacturer) Data sheet
445LEN0100-H10XLB00-V5,0-M-R3 44 l/min 17 / 14 / 10 R928 043 916
51 423
445LEN0160-H10XLB00-V5,0-M-R6 100 l/min 17 / 14 / 10 R928 043 839 445LEN0250-H10XLB00-V5,0-M-R6 144 l/min 17 / 14 / 10 R928 043 840 445LEN0100-H3XLB00-V5,0-M-R3 24 l/min 13 / 10 / 8 R928 043 308 445LEN0160-H3XLB00-V5,0-M-R6 64 l/min 13 / 10 / 8 R928 043 231 445LEN0250-H3XLB00-V5,0-M-R6 96 l/min 13 / 10 / 8 R928 043 232
5.1.5.4.2.2 Filter bowl can be unscrewed to the top -Maintenance indicator flanged to the side - Draining bore in the WO flange surface
Designation (type) Max. flow for initial Δp≤ 1 bar
Oil cleanliness classes according to
ISO 4406
Order number (manufacturer) Data sheet
445LEN0400-H10XLB00-V5,0-M-R6-V3-9 176 l/min 17 / 14 / 10 Upon request
51 423 445LEN0630-H10XLB00-V5,0-M-R6-V3-9 252 l/min 17 / 14 / 10 Upon request 445LEN0400-H3XLB00-V5,0-M-R6-V3-9 144 l/min 13 / 10 / 8 Upon request 445LEN0630-H3XLB00-V5,0-M-R6-V3-9 192 l/min 13 / 10 / 8 Upon request
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx HFC Version 1.5.1 / Apr. 03, 2013 Page 45 of 59
5.1.5.5 Replacement elements - For all pressure ratings - Pleated filter elements
5.1.5.5.1 Pressure differential resistance (collapse pressure) 30 bar
Designation (type) Order number (manufacturer) Data sheet
1.0160 H10XL-A00-0-M-0 ISO 17/14/10 R928 013 315
51 420
1.0250 H10XL-A00-0-M-0 ISO 17/14/10 R928 013 351 1.0400 H10XL-A00-0-M-0 ISO 17/14/10 R928 013 387 1.0630 H10XL-A00-0-M-0 ISO 17/14/10 R928 013 423 1.1000 H10XL-A00-0-M-0 ISO 17/14/10 R928 013 459 2.0100 H10XL-A00-0-M-0 ISO 17/14/10 R928 014 179 2.0160 H10XL-A00-0-M-0 ISO 17/14/10 R928 014 233 2.0250 H10XL-A00-0-M-0 ISO 17/14/10 R928 014 287 2.0400 H10XL-A00-0-M-0 ISO 17/14/10 R928 014 341 2.0630 H10XL-A00-0-M-0 ISO 17/14/10 R928 014 395 1.0160 H3XL-A00-0-M-0 ISO 13/10/8 R928 013 313 1.0250 H3XL-A00-0-M-0 ISO 13/10/8 R928 013 349 1.0400 H3XL-A00-0-M-0 ISO 13/10/8 R928 013 385 1.0630 H3XL-A00-0-M-0 ISO 13/10/8 R928 013 421 1.1000 H3XL-A00-0-M-0 ISO 13/10/8 R928 013 457 2.0100 H3XL-A00-0-M-0 ISO 13/10/8 R928 014 177 2.0160 H3XL-A00-0-M-0 ISO 13/10/8 R928 014 231 2.0250 H3XL-A00-0-M-0 ISO 13/10/8 R928 014 285 2.0400 H3XL-A00-0-M-0 ISO 13/10/8 R928 014 339 2.0630 H3XL-A00-0-M-0 ISO 13/10/8 R928 014 393 5.1.5.5.2 Pressure differential resistance (collapse pressure) 330 bar
Designation (type) Order number (manufacturer) Data sheet
2.0100 H10XL-B00-0-M-0 ISO 17/14/10 R928 014 188
51 420
2.0160 H10XL-B00-0-M-0 ISO 17/14/10 R928 014 242 2.0250 H10XL-B00-0-M-0 ISO 17/14/10 R928 014 296 2.0400 H10XL-B00-0-M-0 ISO 17/14/10 R928 014 350 2.0630 H10XL-B00-0-M-0 ISO 17/14/10 R928 014 404 2.0100 H3XL-B00-0-M-0 ISO 13/10/8 R928 014 186 2.0160 H3XL-B00-0-M-0 ISO 13/10/8 R928 014 240 2.0250 H3XL-B00-0-M-0 ISO 13/10/8 R928 014 294 2.0400 H3XL-B00-0-M-0 ISO 13/10/8 R928 014 348 2.0630 H3XL-B00-0-M-0 ISO 13/10/8 R928 014 402
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx HFC Version 1.5.1 / Apr. 03, 2013 Page 46 of 59
5.1.6 Oil-water heat exchangers
Designation (type) Techn. data Order number (manufacturer) Data sheet
Heat exchanger AB32-12/00-K-006-22 4 kW (18 l/min); up to 10 bar R900 028 816 AB 32-12
5.1.7 Thermostat
Designation (type) Techn. data Order number
(manufacturer) Data sheet
Thermostat TT3050*E35030+TR7432 2 x normally open/normally closed contacts, programmable R901 278 209 by IFM
5.1.8 Accumulators
5.1.8.1 Accumulator tank Accumulators of the type "HAB...-350-4X/..." are not permitted!
Designation (type) Techn. data Order number (manufacturer) Data sheet
HAB10-330-4X/2G09G-2N111-CE 10 liters R901 195 139 50 170 HAB20-330-4X/2G09G-2N111-CE 20 liters R901 195 141
HAB35-330-4X/2G09G-2N111-CE 35 liters R901 195 143
5.1.8.2 Accumulator shut-off block (with manual unloading)
Designation (type) Techn. data Order number (manufacturer) Data sheet
DSV10M0.0/0 S105 G ¾ without pressure relief valve (see separate table) R900 014 956
AB 42-07 DSV10M0.0/0 S107 G1 ¼ without pressure relief valve (see separate table) R900 014 957
DSV10M0.0/0 S109 G2 without pressure relief valve (see separate table) R900 014 958
5.1.8.3 Isolator valve with test connection
Designation (type) Techn. data Order number (manufacturer) Data sheet
Isolator valve AB42-02/AMR-PA for safety block; up to 400 bar; G1/2 R900 015 297 AB 42-02
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx HFC Version 1.5.1 / Apr. 03, 2013 Page 47 of 59
5.2 Control devices
Directional valves (DC24V; K4, with LED; concealed manual override) 5.2.1.1 Spool valves – direct operated 5.2.1.1.1 Size 6
Designation (type) Techn. data Order number (manufacturer) Data sheet
3WE6A6X/EG24N9K4QMBG24
R900 907 012
23 178
4WE6C6X/EG24N9K4
R900 561 272
4WE6D6X/EG24N9K4
R900 561 274
4WE6D6X/EG24N9K4QMBG24
R900 910 413
4WE6D6X/OFEG24N9K4
R900 567 512
4WE6E6X/EG24N9K4
R900 561 278
4WE6J6X/EG24N9K4
R900 561 288
4WE6Y6X/EG24N9K4
R900 561 276
4WE6Y6X/EG24N9K4QMAG24
R900 923 204
5.2.1.1.2 Size 10
Designation (type) Techn. data Order number (manufacturer) Data sheet
3WE10A3X/OFCG24N9K4/MH
R901 241 218
23 327
4WE10D3X/CG24N9K4/MH
R900 908 126
4WE10E3X/CG24N9K4/MH
R900 908 127
4WE10J3X/CG24N9K4/MH
R900 908 125
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx HFC Version 1.5.1 / Apr. 03, 2013 Page 48 of 59
5.2.1.2 Spool valves – pilot operated 5.2.1.2.1 Size 16 (pmax 280 bar)
Designation (type) Techn. data Order number (manufacturer) Data sheet
4WEH16D7X/6EG24N9ETK4/B10
R900 924 874
24 751
4WEH16E7X/6EG24N9ETK4/B10
R900 923 971
4WEH16W7X/6EG24N9ETK4/B10
R901 045 630
4WEH16Y7X/6EG24N9ETK4/B10
R900 248 848
5.2.1.2.2 Sizes 25 and 32
Designation (type) Techn. data Order number (manufacturer) Data sheet
H-4WEH25E6X/6EG24N9ETK4/B10D3
R900 952 126
24 751 H-4WEH25W6X/6EG24N9ETK4/B10D3
R900 929 750
4WEH32E6X/6EG24N9ES2K4/B10
R900 701 440
5.2.1.3 Poppet valves (350 bar, leakage oil-free)
Designation (type) Techn. data Order number (manufacturer) Data sheet
M-3SEW6C3X/420MG24N9K4
R900 566 273
22 058 M-4SEW6D3X/420MG24N9K4
R900 566 293
M-3SEW6U3X/420MG24N9K4
R900 566 283
M-3SEW10C1X/420MG24N9K4
R900 075 565
22 075
M-3SEW10U1X/420MG24N9K4
R900 075 563
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx HFC Version 1.5.1 / Apr. 03, 2013 Page 49 of 59
5.2.2 2-way cartridge valves
5.2.2.1 Cartridge valves
Designation (type) Techn. data Order number (manufacturer) Data sheet
LC16A..E7X/… without damping nose XXXX XXX XXX
21 010
LC16A..D7X/… with damping nose XXXX XXX XXX LC25A..E7X/… without damping nose XXXX XXX XXX LC25A..D7X/… with damping nose XXXX XXX XXX LC32A..E7X/… without damping nose XXXX XXX XXX LC32A..D7X/… with damping nose XXXX XXX XXX LC40A..E7X/… without damping nose XXXX XXX XXX LC40A..D7X/… with damping nose XXXX XXX XXX LC50A..E7X/… without damping nose XXXX XXX XXX LC50A..D7X/… with damping nose XXXX XXX XXX LC63A..E7X/… without damping nose XXXX XXX XXX LC63A..D7X/… with damping nose XXXX XXX XXX LC80A..E6X/… without damping nose XXXX XXX XXX LC80A..D6X/… with damping nose XXXX XXX XXX LC100A..E6X/… without damping nose XXXX XXX XXX LC100A..D6X/… with damping nose XXXX XXX XXX LC125A..E2X/… without damping nose XXXX XXX XXX LC125A..D2X/… with damping nose XXXX XXX XXX 5.2.2.2 Control cover
Designation (type) Techn. data Order number (manufacturer) Data sheet
LFA16D7X/… standard cover XXXX XXX XXX
21 010
LFA16GWB-7X/… with shuttle valve, for directional valve set-up XXXX XXX XXX LFA16H2-7X/… with stroke limitation XXXX XXX XXX LFA16WEA-7X/… for directional valve set-up XXXX XXX XXX LFA16WEB-7X/… for directional valve set-up XXXX XXX XXX LFA25D7X/… standard cover XXXX XXX XXX LFA25G7X/… with shuttle valve XXXX XXX XXX LFA25GWB-7X/… with shuttle valve, for directional valve set-up XXXX XXX XXX LFA25H2-7X/… with stroke limitation XXXX XXX XXX LFA25KWA-7X/… with shuttle valve, for directional valve set-up XXXX XXX XXX LFA25WEA-7X/… for directional valve set-up XXXX XXX XXX LFA25WEMA-7X/… for directional valve set-up + additional port XXXX XXX XXX LFA32D7X/… standard cover XXXX XXX XXX LFA32D19-7X/… for leakage oil-free spool sealing XXXX XXX XXX LFA32EWMA-7X/CA40DQMG24 with limit switch R900 619 603 LFA32GWB-7X/… with shuttle valve, for directional valve set-up XXXX XXX XXX LFA32H3-7X/… with stroke limitation XXXX XXX XXX LFA32WEA-7X/… for directional valve set-up XXXX XXX XXX LFA32WEMA-7X/… for directional valve set-up + additional port XXXX XXX XXX LFA40D7X/… standard cover XXXX XXX XXX LFA40H2-7X/… with stroke limitation XXXX XXX XXX LFA50GWA-7X/… with shuttle valve, for directional valve set-up XXXX XXX XXX LFA50H2-7X/… with stroke limitation XXXX XXX XXX LFA50WEB-7X/… for directional valve set-up XXXX XXX XXX LFA63D-7X/… standard cover XXXX XXX XXX LFA80D-7X/… standard cover XXXX XXX XXX LFA100D-6X/… standard cover XXXX XXX XXX LFA100WEA-6X/… for directional valve set-up XXXX XXX XXX LFA125D-2X/… standard cover XXXX XXX XXX
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx HFC Version 1.5.1 / Apr. 03, 2013 Page 50 of 59
5.2.3 Isolator valves
5.2.3.1 Check valves 5.2.3.1.1 Pipe installation
Designation (type) Techn. data Order number (manufacturer) Data sheet
S6A1.0/ up to 315 bar; up to 18 l/min; 1 bar spring R900 422 881
20 375
S8A1.0/ up to 315 bar; up to 36 l/min; 1 bar spring R900 422 886 S10A1.0/ up to 315 bar; up to 60 l/min; 1 bar spring R900 420 531 S15A0.0/ up to 315 bar; up to 150 l/min; without spring R900 420 536 S15A1.0/ up to 315 bar; up to 150 l/min; 1 bar spring R900 420 537 S15A3.0/ up to 315 bar; up to 150 l/min; 3 bar spring R900 420 521 S15A5.0/ up to 315 bar; up to 150 l/min; 5 bar spring R900 446 477 S20A1.0/ up to 315 bar; up to 180 l/min; 1 bar spring R900 420 525 S20A5.0/ up to 315 bar; up to 180 l/min; 5 bar spring R900 446 369 S25A1.0/ up to 315 bar; up to 350 l/min; 1 bar spring R900 420 511 S30A1.0/ up to 315 bar; up to 450 l/min; 1 bar spring R900 420 519 S30A5.0/ up to 315 bar; up to 450 l/min; 5 bar spring R900 446 709 S52F2-1X/ up to 315 bar; up to 1200 l/min; 5 bar spring R900 446 709 20 392 5.2.3.1.2 Plate cartridge valves (angle valves)
Designation (type) Techn. data Order number (manufacturer) Data sheet
M-SR08 KE05-1X/ up to 315 bar; up to 35 l/min; 0.5 bar spring R900 346 083
20 380
M-SR10 KE05-1X/ up to 315 bar; up to 50 l/min; 0.5 bar spring R900 344 549 M-SR20 KE05-1X/ up to 315 bar; up to 200 l/min; 0.5 bar spring R900 340 979 M-SR25 KE05-1X/ up to 315 bar; up to 300 l/min; 0.5 bar spring R900 344 778 M-SR25 KE50-1X/SO11 up to 315 bar; up to 300 l/min; 5 bar spring R900 926 052 M-SR30 KE05-1X/ up to 315 bar; up to 400 l/min; 0.5 bar spring R900 344 919 M-SR30 KE30-1X/ up to 315 bar; up to 400 l/min; 0.5 bar spring R900 345 961 M-SR30 KE50-1X/SO11 up to 315 bar; up to 400 l/min; 0.5 bar spring R900 923 676 M-SR52 KE05-1X/ up to 315 bar; up to 1200 l/min; 0.5 bar spring R900 306 740 20 395 5.2.3.1.3 Sandwich plate valves
5.2.3.1.3.1 Size 6
Designation (type) Techn. data Order number (manufacturer) Data sheet
Z1S6P15-4X/N up to 315 bar; up to 40 l/min; check valve in P; spring 0.5 bar: R901 219 725
21 534 Z1S6T15-4X/N up to 315 bar; up to 40 l/min; check valve in T;
spring 0.5 bar: ---
5.2.3.1.3.2 Size 10
Designation (type) Techn. data Order number (manufacturer) Data sheet
Z1S10P05-1-4X/N up to 315 bar; up to 100 l/min; check valve in P; spring 0.5 bar: R901 285 818
21 537 Z1S10T05-1-4X/N up to 315 bar; up to 100 l/min; check valve in T;
spring 0.5 bar: Upon request
5.2.3.1.3.3 Size 16
Designation (type) Techn. data Order number (manufacturer) Data sheet
Z1S16P1-1X/ R900 550 413 48 054 Z1S16T1-1X/ Upon request
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx HFC Version 1.5.1 / Apr. 03, 2013 Page 51 of 59
5.2.3.1.3.4 Size 22
Designation (type) Techn. data Order number (manufacturer) Data sheet
Z1S22P1-1X/ R900 523 050 48 056 Z1S22T1-1X/ R900 926 565 5.2.3.2 Check valves – hydraulically pilot operated 5.2.3.2.1 Pipe installation
Designation (type) Techn. data Order number (manufacturer) Data sheet
SL10GA1-4X/ up to 315 bar; up to 150 l/min; with pre-opening + leakage oil connection R900 483 370
21 468
SL10GB1-4X/100 up to 315 bar; up to 150 l/min; without pre-opening + leakage oil connection R900 451 135
SL20GA1-4X/ up to 315 bar; up to 350 l/min; with pre-opening + leakage oil connection R900 587 554
SL30GA1-4X/ up to 315 bar; up to 550 l/min; with pre-opening + leakage oil connection R900 587 556
SV10GA1-4X/ up to 315 bar; up to 150 l/min; with pre-opening R900 483 368
SV20GA1-4X/ up to 315 bar; up to 350 l/min; with pre-opening R900 587 550 5.2.3.2.2 Subplate mounting
Designation (type) Techn. data Order number (manufacturer) Data sheet
SV30PA1-4X/ up to 315 bar; up to 350 l/min; with pre-opening R900 587 558 21 468
5.2.3.2.3 Sandwich plate design
Designation (type) Techn. data Order number (manufacturer) Data sheet
Z2S6-1-6X/ up to 315 bar; up to 40 l/min; check valve in A and B; spring 1.5 bar:
R900 347 495 21 548
Z2S10-1-3X/ up to 315 bar; up to 100 l/min; check valve in A and B; spring 1.5 bar:
R900 407 394 21 553
Z2S16-1-5X/ up to 315 bar; up to 300 l/min; check valve in A and B; spring 3 bar:
R900 407 394 21 558
Z2S22-1-5X/ up to 315 bar; up to 450 l/min; check valve in A and B; spring 3 bar:
R900 407 394 21 564
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx HFC Version 1.5.1 / Apr. 03, 2013 Page 52 of 59
5.2.4 Pressure valves
5.2.4.1 Pressure relief valves 5.2.4.1.1 Direct operated
5.2.4.1.1.1 Subplate mounted valves Size 6
Designation (type) Techn. data Order number (manufacturer) Data sheet
DBDS6P1X/50 up to 50 bar; up to 50 l/min R900423 732
25 402 DBDS6P1X/100 up to 100 bar; up to 50 l/min R900 423 728 DBDS6P1X/200 up to 200 bar; up to 50 l/min R900 423 729 DBDS6P1X/315 up to 315 bar; up to 50 l/min; R900 423 730
Size 10
Designation (type) Techn. data Order number (manufacturer) Data sheet
DBDS10P1X/50 up to 50 bar; up to 120 l/min R900 425 661
25 402 DBDS10P1X/100 up to 100 bar; up to 120 l/min R900 424 155 DBDS10P1X/200 up to 200 bar; up to 120 l/min R900 424 157 DBDS10P1X/315 up to 315 bar; up to 120 l/min R900 424 158 Size 20
Designation (type) Techn. data Order number (manufacturer) Data sheet
DBDS20P1X/50 up to 50 bar; up to 250 l/min R900 424 272
25 402 DBDS20P1X/100 up to 100 bar; up to 250 l/min R900 424 274 DBDS20P1X/200 up to 200 bar; up to 250 l/min R900 424 277 DBDS20P1X/315 up to 315 bar; up to 250 l/min R900 424 278
5.2.4.1.1.2 Screw-in cartridge valves Size 6
Designation (type) Techn. data Order number (manufacturer) Data sheet
DBDS6K1X/50 up to 50 bar; up to 50 l/min; R900 423 727
25 402 DBDS6K1X/100 up to 100 bar; up to 50 l/min; R900 423 723 DBDS6K1X/200 up to 200 bar; up to 50 l/min; R900 423 724 DBDS6K1X/315 up to 315 bar; up to 50 l/min; R900 423 725 Size 10
Designation (type) Techn. data Order number (manufacturer) Data sheet
DBDS10K1X/50 up to 50 bar; up to 120 l/min; R900 424 153
25 402 DBDS10K1X/100 up to 100 bar; up to 120 l/min; R900 424 147 DBDS10K1X/200 up to 200 bar; up to 120 l/min; R900 424 149 DBDS10K1X/315 up to 315 bar; up to 120 l/min; R900 424 150 Size 20
Designation (type) Techn. data Order number (manufacturer) Data sheet
DBDS20K1X/50 up to 50 bar; up to 250 l/min; R900 424 205
25 402 DBDS20K1X/100 up to 100 bar; up to 250 l/min; R900 424 267 DBDS20K1X/200 up to 200 bar; up to 250 l/min; R900 423 269 DBDS20K1X/315 up to 315 bar; up to 250 l/min; R900 424 271
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx HFC Version 1.5.1 / Apr. 03, 2013 Page 53 of 59
5.2.4.1.1.3 Valves for threaded connection Size 6
Designation (type) Techn. data Order number (manufacturer) Data sheet
DBDS6G1X/50 up to 50 bar; up to 50 l/min; R900 423 722
25 402 DBDS6G1X/100 up to 100 bar; up to 50 l/min; R900 423 717 DBDS6G1X/200 up to 200 bar; up to 50 l/min; R900 423 719 DBDS6G1X/315 up to 315 bar; up to 50 l/min; R900 423 720 Size 10
Designation (type) Techn. data Order number (manufacturer) Data sheet
DBDS10G1X/50 up to 50 bar; up to 120 l/min; R900 424 745
25 402 DBDS10G1X/100 up to 100 bar; up to 120 l/min; R900 424 738 DBDS10G1X/200 up to 200 bar; up to 120 l/min; R900 424 140 DBDS10G1X/315 up to 315 bar; up to 120 l/min; R900 424 742 Size 20
Designation (type) Techn. data Order number (manufacturer) Data sheet
DBDS20G1X/50 up to 50 bar; up to 250 l/min; R900 424 276
25 402 DBDS20G1X/100 up to 100 bar; up to 250 l/min; R900 424 170 DBDS20G1X/200 up to 200 bar; up to 250 l/min; R900 424 172 DBDS20G1X/315 up to 315 bar; up to 250 l/min; R900 424 174
5.2.4.1.1.4 Sandwich plate valves Size 6
Designation (type) Techn. data Order number (manufacturer) Data sheet
HSZ06A100-3X/S025M00 Sandwich plate with pressure relief function P->T R900 936 130 48 050
ZDBT-XA2-1X/160 Sandwich plate with pressure relief function A->T 0811 104 120
25 724 ZDBT-XP2-1X/160 Sandwich plate with pressure relief function P->T 0811 104 112
ZDBT-XP2-1X/315 Sandwich plate with pressure relief function P->T 0811 104 113
Size 10
Designation (type) Techn. data Order number (manufacturer) Data sheet
HSZ10A100-3X/M00 Sandwich plate with pressure relief function P->T R900 526 220 48 052
5.2.4.1.2 Pilot operated
5.2.4.1.2.1 Subplate mounted valves Size 20
Designation (type) Techn. data Order number (manufacturer) Data sheet
DB20-2-5X/200XY up to 200 bar; up to 500 l/min; R900 500 218 25 802 DB20-2-5X/50 up to 50 bar; up to 500 l/min; R900 597 212 Size 30
Designation (type) Techn. data Order number (manufacturer) Data sheet
DB30-2N5X/200E up to 200 bar; up to 650 l/min; R900 769 503 25 802 DB30-2N5X/210E up to 210 bar; up to 650 l/min; R900 769 505
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx HFC Version 1.5.1 / Apr. 03, 2013 Page 54 of 59
5.2.4.1.2.2 Screw-in cartridge valves Size 10
Designation (type) Techn. data Order number (manufacturer) Data sheet
DB10K2-4X/50Y up to 50 bar; up to 100 l/min; R900 408 654 25 731 DB10K2-4X/100Y up to 100 bar; up to 100 l/min; R900 430 681
DB10K2-4X/200Y up to 200 bar; up to 100 l/min; R900 481 084
5.2.4.1.2.3 2-way cartridge valves Cartridge valve
Designation (type) Techn. data Order number (manufacturer) Data sheet
LC16DB20E7X/ R900 912 531
21 050
LC16DB40E7X/ R900 912 532 LC25DB40D7X/ R900 912 555 LC32DB20D7X/ R900 912 556 LC32DB20E7X/ R900 912 543 LC32DB40E7X/ R900 910 773 LC32DB40E7X/004 leakage oil-free R900 919 236 LC32DB50E7X/ R900 947 666 LC402DB20D7X/ R900 928 821 LC40DB20E7X/ R900 938 012 LC40DB40E7X/ R900 927 969 LC40DB40E7X/-104 leakage oil-free R900 947 917 Control cover
Designation (type) Techn. data Order number (manufacturer) Data sheet
LFA16DB2-7X/… pressure limitation XXXX XXX XXX
21 050
LFA16DBWD1-7X/… pressure limitation with shut-off XXXX XXX XXX LFA32DAWB2-7X/… pressure limitation with shut-off XXXX XXX XXX LFA32DB2-7X/… pressure limitation XXXX XXX XXX LFA32DBE-7X/… proportional pressure limitation XXXX XXX XXX LFA32DBEM-7X/… proportional pressure limitation XXXX XXX XXX LFA32DBW-7X/… pressure limitation with shut-off XXXX XXX XXX LFA32DR2-7X/… pressure reduction XXXX XXX XXX LFA40DB2-7X/… pressure limitation XXXX XXX XXX LFA40DBW2-7X/… pressure limitation with shut-off XXXX XXX XXX LFA40DR2-7X/… pressure reduction XXXX XXX XXX 5.2.4.2 Pressure reducing valves 5.2.4.2.1 Direct operated
5.2.4.2.1.1 Subplate mounted valves
Size 6
Designation (type) Techn. data Order number (manufacturer) Data sheet
DR6DP2-5X/150Y up to 150 bar; up to 60 l/min; with check v. R900 413 242 26 564 DR6DP2-5X/210YM up to 210 bar; up to 60 l/min; without check v. R900 455 316
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx HFC Version 1.5.1 / Apr. 03, 2013 Page 55 of 59
Size 10
Designation (type) Techn. data Order number (manufacturer) Data sheet
DR10DP2-4X/75Y up to 75 bar; up to 80 l/min; with check v. R900 500 471 26 580 DR10DP2-4X/210Y up to 210 bar; up to 80 l/min; with check v. R900 594 125
5.2.4.2.1.2 Sandwich plate valves
Size 6
Designation (type) Techn. data Order number (manufacturer) Data sheet
ZDR6DA2-4X/150YM up to 150 bar; up to 80 l/min; in channel A; without check v. R900 445 958
26 570
ZDR6DA2-4X/150Y up to 150 bar; up to 50 l/min; in channel A; with check v. R900 410 849 ZDR6DA2-4X/210YM up to 210 bar; up to 50 l/min; in channel A; without check v. R900 423 213 ZDR6DA2-4X/210Y up to 210 bar; up to 50 l/min; in channel A; with check v. R900 410 855 ZDR6DB2-4X/150YM up to 150 bar; up to 50 l/min; in channel B; without check v. R900 431 172 ZDR6DB2-4X/210YM up to 210 bar; up to 50 l/min; in channel B; without check v. R900 463 269 ZDR6DP2-4X/150YM up to 150 bar; up to 50 l/min; in channel P; without check v. R900 483 787 ZDR6DP2-4X/210YM up to 210 bar; up to 50 l/min; in channel P; without check v. R900 483 788
Size 10
Designation (type) Techn. data Order number (manufacturer) Data sheet
ZDR10DA2-5X/150YM up to 150 bar; up to 80 l/min; in channel A; without check v. R900 406 225
26 585
ZDR10DA2-5X/150Y up to 150 bar; up to 80 l/min; in channel A; with check v. R900 410 884 ZDR10DA2-5X/210YM up to 210 bar; up to 80 l/min; in channel A; without check v. R900 428 474 ZDR10DA5-5X/210Y up to 210 bar; up to 80 l/min; in channel A; with check v. R900 406 651 ZDR10DB2-5X/150YM up to 150 bar; up to 80 l/min; in channel B; without check v. R900 408 340 ZDR10DB2-5X/210YM up to 210 bar; up to 80 l/min; in channel B; without check v. R900 443 484 ZDR10DP2-5X/150YM up to 150 bar; up to 80 l/min; in channel P; without check v. R900 410 880 ZDR10DP2-5X/210YM up to 210 bar; up to 80 l/min; in channel P; without check v. R900 410 876 5.2.4.2.2 Pilot operated Size 10
Designation (type) Techn. data Order number (manufacturer) Data sheet
DR10-5-5X/200YM up to 200 bar; up to 150 l/min; without check v. R900 598 358 26 892 Size 20
Designation (type) Techn. data Order number (manufacturer) Data sheet
DR20-5-5X/200YM up to 200 bar; up to 300 l/min; without check v. R900 597 233 26 892
5.2.4.2.2.1 2-way cartridge valves Cartridge valve: See chapter 6.2.4.1.2.3 Control cover
Designation (type) Techn. data Order number (manufacturer) Data sheet
LFA32DR2-7X/… pressure reduction XXXX XXX XXX 21 050 LFA40DR2-7X/… pressure reduction XXXX XXX XXX
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx HFC Version 1.5.1 / Apr. 03, 2013 Page 56 of 59
5.2.5 Flow control valves
5.2.5.1 Throttle valves 5.2.5.1.1 Pipe fitting
Designation (type) Techn. data Order number (manufacturer) Data sheet
MG6G1X/V up to 315 bar; up to 15 l/min; G1/4; R900 437 338
27 219
MG8G1X/V up to 315 bar; up to 30 l/min; G3/8; R900 438 885 MG10G1X/V up to 315 bar; up to 50 l/min; G1/2; R900 422 145 MG15G1X/V up to 315 bar; up to 125 l/min; G3/4; R900 437 653 MG20G1X/V up to 315 bar; up to 200 l/min; G1; R900 422 150 MG25G1X/V up to 315 bar; up to 300 l/min; G1 1/4; R900 413 979 MG30G1X/V up to 315 bar; up to 400 l/min; G1 1/2; R900 422 453 5.2.5.2 Throttle check valves 5.2.5.2.1 Pipe fitting
Designation (type) Techn. data Order number (manufacturer) Data sheet
MK6G1X/V up to 315 bar; up to 15 l/min; G1/4; R900 423 340
27 219
MK8G1X/V up to 315 bar; up to 30 l/min; G3/8; R900 423 343 MK10G1X/V up to 315 bar; up to 50 l/min; G1/2; R900 424 579 MK15G1X/V up to 315 bar; up to 125 l/min; G3/4; R900 423 326 MK20G1X/V up to 315 bar; up to 200 l/min; G1; R900 423 328 MK25G1X/V up to 315 bar; up to 300 l/min; G1 1/4; R900 423 330 MK30G1X/V up to 315 bar; up to 400 l/min; G1 1/2; R900 423 333 5.2.5.2.2 Sandwich plate valves Size 6
Designation (type) Techn. data Order number (manufacturer) Data sheet
Z2FS6A2-4X/2Q up to 315 bar; up to 80 l/min; in channel A; discharge throttle. R900 440 565
27 506 Z2FS6B2-4X/2Q up to 315 bar; up to 80 l/min; in channel B; discharge throttle. R900 423 224
Z2FS6-2-4X/2Q up to 315 bar; up to 80 l/min; in channel A+B R900 481 622 Size 10
Designation (type) Techn. data Order number (manufacturer) Data sheet
Z2FS10-5-3X/ up to 315 bar; up to 160 l/min; in channel A+B R900 989 095
27 518 Z2FS10A5-3X/S2 up to 315 bar; up to 160 l/min; in channel A; discharge throttle. R900 571 890
Z2FS10B5-3X/S2 up to 315 bar; up to 160 l/min; in channel B; discharge throttle. R900 989 106
Size 16
Designation (type) Techn. data Order number (manufacturer) Data sheet
Z2FS16A8-3X/S2 up to 350 bar; up to 250 l/min; in channel A Upon request 27 526 Z2FS16-3X/S2 up to 350 bar; up to 250 l/min; in channel
A+B Upon request
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx HFC Version 1.5.1 / Apr. 03, 2013 Page 57 of 59
5.2.5.3 Flow control valves 5.2.5.3.1 Subplate mounted valves Size 6
Designation (type) Techn. data Order number (manufacturer) Data sheet
2FRM6A76-3X/32QR up to 315 bar; up to 32 l/min; with check valve Upon request 28 163 Size 10
Designation (type) Techn. data Order number (manufacturer) Data sheet
2FRM10-3X/25LB up to 315 bar; up to 25 l/min; Upon request 28 389 2FRM10-3X/50LB up to 315 bar; up to 50 l/min; Upon request 5.2.5.3.2 Screw-in cartridge valves Size 6
Designation (type) Techn. data Order number (manufacturer) Data sheet
2FRM6K2-1X/6QR up to 315 bar; up to 6 l/min; Upon request 28 155 2FRM6K2-1X/32QR up to 315 bar; up to 32 l/min; Upon request Size 10
Designation (type) Techn. data Order number (manufacturer) Data sheet
2FRM10K2-1X/60QR up to 315 bar; up to 60 l/min; Upon request 28 155
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx HFC Version 1.5.1 / Apr. 03, 2013 Page 58 of 59
5.3 Proportional and servo valves
Preferably, components with integrated electronics are to be used. If this is not possible, the respective control electronics must be added.
5.3.1 Directional valves
5.3.1.1 Spool valves Designation (type) Techn. data Order number
(manufacturer) Data sheet
4WRKE10…3X/6EG24…K31/…D3M up to 350 bar; with integrated electronics XXXX XXX XXX
29 075 4WRKE16…3X/6EG24…K31/…D3M up to 350 bar; with integrated electronics XXXX XXX XXX 4WRKE25…3X/6EG24…K31/…D3M up to 350 bar; with integrated electronics XXXX XXX XXX 4WRKE35…3X/6EG24…K31/…D3M up to 350 bar; with integrated electronics XXXX XXX XXX 4WRLE16…Z.SJ-3XH/G24:K0/A1M P,A,B up to 350 bar; with integrated electronics XXXX XXX XXX 29 089 4WRPE6…SJ-2X/G24K0.M up to 315 bar; with integrated electronics XXXX XXX XXX
29 025 4WRPE10… SJ-2X/G24K0.M up to 315 bar; with integrated electronics XXXX XXX XXX 4WRVE25…-2XH/G24.K0/B5M P,A,B up to 350 bar; with integrated electronics XXXX XXX XXX 29 077 4WRZ10…-7X/...M up to 350 bar; without integrated electronics XXXX XXX XXX 29 115 5.3.1.2 High-response cartridge valve 2-way and 3-way version
Designation (type) Techn. data Order number
(manufacturer) Data sheet
2WRCE32S…-3X/PG24K31/… up to 420 bar, 2-way cartridge valve XXXX XXX XXX
29 137
2WRCE40S…-3X/PG24K31/… up to 420 bar, 2-way cartridge valve XXXX XXX XXX 2WRCE63K…-1X/SG15/M… up to 420 bar, 2-way cartridge valve XXXX XXX XXX 2WRCE80K…-1X/SG15/M… up to 420 bar, 2-way cartridge valve XXXX XXX XXX 2WRCE100K…-1X/SG15/M… up to 420 bar, 2-way cartridge valve XXXX XXX XXX 3WRCE63L…-1X/SG15/M … up to 420 bar, 3-way cartridge valve XXXX XXX XXX 3WRCE80L…-1X/SG15/M… up to 420 bar, 3-way cartridge valve XXXX XXX XXX
5.3.2 Pressure valves: Pressure relief valves
Designation (type) Techn. data Order number (manufacturer) Data sheet
DBET-6X/…G24K4…SO33 up to 420 bar; without integrated electronics Upon request 29 162 DBETE-6X/…G24K31…SO33 up to 420 bar; with integrated electronics Upon request DBETR-1X/…G24K4M up to 350 bar; without integrated electronics Upon request 29 166 (Z)DBEE6…-1X/…G24NK31M up to 315 bar; with integrated electronics Upon request 29 158
5.3.3 Flow control valves: 2-way proportional throttle valve for block installation
Designation (type) Techn. data Order number (manufacturer) Data sheet
FES40CA-3X/…K4…M up to 315 bar; without integrated electronics XXXX XXX XXX 29 209 FESE40CA-3X/…K0…M up to 315 bar; with integrated electronics XXXX XXX XXX
Bosch_Rexroth_AG_Freigabeliste_VW_Agg_Hydraulik_20130403_en.docx HFC Version 1.5.1 / Apr. 03, 2013 Page 59 of 59
5.4 Cylinders
5.4.1 Tie rod cylinders
Piston rod with square, with drain port if required Designation (type) Techn. data
Order number (manufacturer) Data sheet
CDT3....F1X/...H…E…TB… 160 bar; Pistons 25-200 mm; rods 12-140 mm XXXX XXX XXX
17 039 CGT3....F1X/...H…E…TB… 160 bar;
Pistons 25-200 mm; rods 12-140 mm XXXX XXX XXX
H = Piston rod hardened and hard chromium-plated E = End position cushioning adjustable on both sides B = with leakage oil connection (only for concealed cylinders)
5.5 Accessories
5.5.1 Cover plates
Designation (type) Techn. data
Order number (manufacturer) Data sheet
HSA06A001-3X/M00 up to 315 bar; as cover plate with porting pattern A06 R900 316 232 48 042
HSA06A064-3X/M00 Cover plate with pressure relief function P-T R900 579 914 ---
Notes: