An installation guide to slab edge insulation that meets ...

Post on 02-Dec-2021

4 views 0 download

Transcript of An installation guide to slab edge insulation that meets ...

1 | P a g e

An installation guide to slab edge insulation that meets the mandatory 2018 IECC code requirements C402.2.4 and R402.2.10. The blue below represents R-10 insulation.

1 2

2 | P a g e

An installation guide to slab edge insulation that meets the mandatory 2018 IECC code requirements C402.2.4 and R402.2.10. The blue below represents R-10 insulation.

3 4

TRIM BOARD (bsmt finish)

5”

8”

Note: Consult with your structural engineer regarding reducing width of stem wall to 5”.

3 | P a g e

An installation guide to slab edge insulation that meets the mandatory 2018 IECC code requirements C402.2.4 and R402.2.10. The blue below represents R-10 insulation.

Protective flashing to cover insulation

Min 10” below grade

5 6

4 | P a g e

An installation guide to slab edge insulation that meets the mandatory 2018 IECC code requirements C402.2.4 and R402.2.10. The blue below represents R-10 insulation.

7

Protective flashing to cover insulation

5 | P a g e

An installation guide to slab edge insulation that meets the mandatory 2018 IECC code requirements C402.2.4 and R402.2.10. The blue below represents R-10 insulation.

Drawings directly above: Insulation does not meet minimum code requirement.

R402.2.10 Slab-on-grade floors. …the insulation shall extend downward from the top of the slab on the outside or inside of the foundation wall.