Post on 05-Jan-2016
description
AirPlus!
Standard SystemStandard SystemStandard Fluid De/Anti-icing
Deicing Fluidat 40 gpm
Deicing Fluidat 40 gpm
GLOBALAirPlus!GLOBAL
AirPlus!GLOBAL
AirPlus!TM
Fluid Injection
6 gpm700 mph6 gpm700 mph
30-90%
Reduction!30-90%
Reduction!
GLOBALAirPlus!GLOBAL
AirPlus! TM
Fluid “over” Air
Fluid Over Air with
Fluid Injection
Fluid Over Air with
Fluid Injection
GLOBALAirPlus!GLOBAL
AirPlus! TM
GLOBALAirPlus!
Air Source is a supercharger used in marine applications.
Located under cab for maximum efficiency
1. Type I/IV Spray Nozzle - 40 gpm Type I adjustable spray nozzle. 20 gpm Type IV adjustable spray nozzle. Adjustable from stream to fan.
2. Type I Spray Nozzle - 20 gpm spray nozzle straight stream for deicing up to 25 feet.
3. Air-Plus with Fluid Injection - Forced air can be used alone, with with fluid injection, Forced air with Deicing fluid or Forced Air with Fluid Injection and Deicing Fluid.
1
2
3
3-Barrel Nozzle Forced Air Deicing System
GLOBAL’s AirPlus!
Deicing System
• Utilizes Forced Air– To remove loose accumulations
• With or without fluid
• Most often will be followed by– Heated Deicing Fluid– Or, Cold Anti-Icing Fluid
• Significantly reduces glycol consumption
GLOBAL’s AirPlus!
Deicing System• Four methods
– Forced Air – Forced Air, plus Fluid Injection– Fluid Over Forced Air– Fluid Only
• Protected under license for:– use of Williams, “Plurity of Fluid” Patent– use of USAF, “Air Nozzle & Systems” Patent
GLOBAL’s AirPlus!
Deicing System• Researched by Wright Labs at Wright Patterson Air Force Base
• Access to U.S.A.F. scientists & facilities• Discovered that correct Air
– Velocity- breaks coverage loose– Volume- moves coverage away
• The key is in the delivery nozzle design• USAF patented a
– sub-sonic, axisymmetrical, non-convergent, non flared, perfectly choked nozzle
GLOBAL’s AirPlus!
Deicing System• Provides Forced Air
– Speed of 800+ mph– 1,350 cfm– 11 psi
• Nozzle Diameter of 2 inches
• Air Source is a “continuos duty” rated blower
• Located at enclosed cab for max efficiency
• Approved by Boeing & USAF
Nozzle Up/Down & Rotation Controls
Boom Operation & Cab Rotation Controls
Air SourceAir Supply Tube
Fluid Injection System
Deice/anti-ice fluid nozzle
SpotlightEntry Platform
Front Entry Door
Floodlights
GLOBAL’s AirPlus! Deicing System
DATE - February 23, 2007
FLIGHT A/C MODETRUCK
#15TRUCK
#14TOTAL
GALLONS
% SAVINGS
2327 EMB HIGH FLOW 40GPM 31 35 66 -2453 EMB LOW FLOW 20GPM 18 17 35 53.03%
2514 EMBAirPlus WITH FLUID
INJECTION 9GPM 4 3 7 89.39%
2253 EMB
AirPlus with FLUID INJECTION 9GPM and LOW FLOW 20GPM 24 21 45 31.82%
CLEVELAND HOPKINS INTERNATIONAL AIRPORTWeather - 31F / Light Snow
Trucks - Global Ultimate 2200 - Single Operator with AirPlus
Global AirPlus deicers in operation with AeroMag/Contego at CLE