Post on 14-Feb-2017
ACCESSORIESCARDIOLOGY2 0 1 3 / 2 0 1 4
Fighting Disease with Electronics
www.nihonkohden.net2 www.nihonkohden.net2
Dear Customer,
For more than 60 years NIHON KOHDEN has been one of Japan’s leading players in medical technology development and manufacturing and has subsidiaries and representative o� ces in Europe, the US, as well as in the Middle and Far East.
“Fighting Disease with Electronics“ – our corporate philosophy – refl ects the high standards we have set ourselves in combating disease by developing medical systems, contributing to higher quality of life for patients.
Our large product range of accessories and consumables is known for its outstanding quality, ease of use and reliability. Please note, that only the use of original NIHON KOHDEN approved accessories and consumables guarantee optimal examination results and make an important contribution towards ensuring that your device will continue to function impeccably and reliably even in years to come, while preserving the device’s features and functional capabilities.
As your partner in cardiology, NIHON KOHDEN provides only tested and approved product solutions from standard vital signs parameter such as ECG, SpO2 , NIBP or Temperature to specifi c parameters like Capnography or IBP Measurement. Our commitment to ensure continually highest quality allows you the best care of your patients and enhances your ECG, AED/TRN and Defi brillator performances.
NIHON KOHDEN invites you to discover the quality and features of our complete accessories and consumables portfolio in this
catalogue. Call today for more information or order directly!
Best regards,
NIHON KOHDEN EUROPE GmbH
Kristin Baar
Product Manager Accessories & Consumables
Introduction
Introduction
www.nihonkohden.net3 www.nihonkohden.net3
Accessories & Consumables Cardiology
Content
User Guide 6
Product Innovation & Smart Cable TM Technology 7
Highest Safety and Quality Standards 8
Quick Guide Electrocardiographs, Defi brillators, AED/TRN 9
1 ECG Measurement 10
Typical Arrhythmia Waveforms 11
1.1 ECG Cables 12
1.1.11.1.21.1.31.1.4
ECG 10-Lead CableECG 12/15-Lead CableECG Veterinary 5-Lead CableAdditional Cable Accessories
13141515
1.2 ECG Electrodes 16
1.2.11.2.21.2.31.2.41.2.51.2.6
Clip Electrodes Chest & Plate ElectrodesTab ElectrodesECG Electrodes for AdultsECG Electrodes for Children, Infants & NeonatesECG Electrode Adapter
171819202121
1.4 ECG Batteries 22
1.5 ECG Paper 24
1.6 Additional ECG Accessories 27
2 Accessories for Defi brillators 30
2.1 Defi brillator Batteries & Battery Charger 31
2.2 Defi brillator Paper 33
2.3 Defi brillator Bags 35
www.nihonkohden.net4 www.nihonkohden.net4
2.4 Disposable Defi brillator Pads 37
2.4.12.4.2
Disposable Pads with NIHON KOHDEN ConnectorDisposable Pads with R2 Connector
3839
2.5 Paddle Electrodes 40
2.5.12.5.22.5.3
Internal Paddle Electrode with Discharge Button for Series TEC-8300Internal Paddle Electrode with Discharge Button for TEC-5500/7700Neonate Paddle Adapter for TEC-5500/7700
414242
2.6 ECG Measurement 43
Typical Arrhythmia Waveforms 44
2.6.1 ECG Cables 45
2.6.1.1 ECG Cables for TEC-8300 46
2.6.1.1.12.6.1.1.2
ECG 3/6-Lead CablesECG 10-Lead Cables
4748
2.6.1.2 ECG Cables for TEC-5500 & TEC-7700 49
2.6.1.2.12.6.1.2.22.6.1.2.3
ECG 3-Lead CablesECG 5-Lead CablesFurther Defi brillator Connection Cables
505152
2.7 ECG Electrodes for Defi brillators 53
2.7.12.7.2
ECG Electrodes for AdultsECG Electrodes for Children, Infants & Neonates
5455
2.8 SpO2 Measurement 56
2.8.1 SpO2 Cables 57
2.8.2 SpO2 Probes 59
2.8.2.12.8.2.22.8.2.2.12.8.2.2.22.8.2.2.32.8.2.2.4
Reusable SpO2 ProbesDisposable SpO2 ProbesDisposable SpO2 Probes 24 pcs/box - cable length: 0.8 mDisposable SpO2 Probes 24 pcs/box - cable length: 1.6 mDisposable SpO2 Probes 5 pcs/box - cable length: 0.8 mDisposable SpO2 Probes 5 pcs/box - cable length: 1.6 m
616363646466
Content
www.nihonkohden.net5 www.nihonkohden.net5
2.9 ETCO2 Measurement (Capnography) 68
ETCO2 Selection Guide 69
ETCO2 Measurement Overview 70
2.9.1 ETCO2 Mainstream 71
2.9.1.12.9.1.22.9.1.3
Intubated Expired ETCO2
Intubated Expired and Inspired ETCO2 - “Opening a New Era in Capnography“Intubated and Non-Intubated Expired ETCO2 CapOne - “Opening a New Era in Capnography“
727374
2.10 Temperature Measurement 76
2.10.12.10.2
Standard Temperature MeasurementMeasurement of 2 Additional Temperatures
7777
2.11 NIBP Measurement (Non-invasive Blood Pressure) 78
2.11.12.11.22.11.32.11.3.12.11.3.2
NIBP Air HosesReusable NIBP Cu� s - NEW YAWARA CUFF 2Disposable NIBP Cu� sDisposable NIBP Cu� s for Infants & ChildrenDisposable NIBP Cu� s for Adults
7980828283
2.12 IBP Measurement (Invasive Blood Pressure) 84
2.12.12.12.2
IBP Transducer Cable with Direct ConnectionIBP Transducer Cable with Adapter Cable K952
8586
2.13 Portable CPR 88
2.14 Additional Defi brillator Accessories 90
3 Accessories for AED & Training Unit 92
3.13.2
Accessories for AED UnitsAccessories for AED Training Unit TRN-2100K
9696
Accessory Order Form 97
Index as per Supply Code 98
Index as per Model Code 100
Content
www.nihonkohden.net6 www.nihonkohden.net6
Care of Environment NIHON KOHDEN is making every possible e� ort to ensure that the actions of the company and its employees contribute to
preserving the environment. In order to conserve paper resources, we decided a more environment friendly approach which allows
us to update the catalogue more frequently in the future. Therefore the new accessories and consumables catalogue was designed
for view on your computer. It allows you to zoom pictures in order to see more details of the product. If you need indeed certain
chapters in print version, you can easily select and print them.
Find the right accessories in the catalogue You do not know exactly which article you need for your examination?
Following this user guide you will fi nd the content of this catalogue which is organized into parameter categories. In a particular
category you will see a list of accessories and consumables with corresponding supply codes, model codes, descriptions and
pictures. If you are not sure if one of the listed products will fi t to your requirements, please contact us or one of our regional
representatives.
You already know the article that you need for your examination?
In the index of the catalogue , from page 98 to page 99, the articles are listed alphabetically as per supply code; page 100, the products are
listed alphabetically as per model code. They will help you to fi nd directly the according product page.
If you are using the PDF version, simply use the “search function” of this by entering the description, supply or model code.
Or just click on the related chapter on the left side of the document.
Order informationTo order NIHON KOHDEN accessories and consumables or to get more information, please refer to the indicated regional
NIHON KOHDEN representatives below.
For your convenience, we have a printable order form at the end of this catalogue so that you can fax in your order directly or
mail/e-mail it to us. Please make sure to fi ll out all requested information as well as the required supply code and according
quantity. Please check the general terms and conditions including delivery time, payment and general warranty with your
responsible regional NIHON KOHDEN representatives:
User Guide
For Germany, Austria, Switzerland and BeneluxNIHON KOHDEN EUROPE GmbH, Vertrieb Deutschland Albert-Einstein-Ring 9, 14532 Kleinmachnow, DeutschlandFax: +49 (0) 33203/573-19, E-Mail: bestellung@nke.de For Spain and Portugal NIHON KOHDEN IBERICA S.L. C/Ulises, 75A, 28043 Madrid, SpainFax: +34 91 300 46 76, E-Mail: info@nkib.esFor United KingdomNIHON KOHDEN UNITED KINGDOM Ltd. Tolworth Tower – 19th Floor, Ewell Road, Surbiton, Surrey KT6 7EL, United KingdomFax: +44 (0) 20 83 90 46 75, E-Mail: mail@nihonkohden.co.uk
For France NIHON KOHDEN FRANCE SARL 8, rue François Delage, 94230 Cachan, FranceFax: +33 (0) 1 49 08 93 32, E-Mail: info@nkfrance.frFor Italy NIHON KOHDEN ITALIA S.r.l. Via Fratelli Bronzetti, 28, 24124 Bergamo, ItalyFax: +39 (0) 35-232546, E-Mail: info@nkitaly.com For all other European Countries, Russia, Turkey and Israel NIHON KOHDEN EUROPE GmbHRai� eisenstraße 10, 61191 Rosbach v. d. H., GermanyFax: +49 (0) 6003/827-599, E-Mail: info@nke.de
User Guide
www.nihonkohden.net7 www.nihonkohden.net7 Product Innovation & Smart Cable™ Technology
With NIHON KOHDEN Smart Cable Technology, you will get complete mo-dular fl exibility at a signifi cantly reduced cost and without all of the incon-venience associated with traditional modular systems. Smart CableTM technology miniaturizes circuits found in traditional modules and em-beds that circuitry into the cable. When you plug a Smart CableTM into a MULTI connector, it automatically detects the type of parameter and starts measuring.
Smart Connector Technology is available for the following parameters:
NIHON KOHDEN - Smart Cable™ Technology A Cost-E� ective Solution to Modular Monitoring
Synthesized 18-lead ECG - Identify Invisible Ischemia -A New Technology for More Informative ECG Exam
What is Synthesized ECG ?
Synthesized 18-lead ECG uses the 12-lead ECG waveforms to mathematically derive the waveforms of the right chest leads (V3R, V4R, V5R)
and back leads (V7, V8, V9). The measurement procedure is the same as the standard 12-lead ECG but more information can be obtained.
18-lead synthesized ECG is expected to be useful in detecting right side and posterior infarction.
The most common ECG exam is the standard 12-lead ECG. It is simple to measure, has low burden on the body, and observing the heart from these 12 directions provides a lot of information which has a wide range of clinical applications.
However, some areas, especially pathological change in the right ventricle and the posterior wall cannot be observed from the 12-lead ECG. In order to actually measure the right chest (V3R, V4R, V5R) and back (V7, V8, V9) areas, it is necessary to use di� erent elec-trode positions than the standard 12-lead ECG. In particular, electrodes must also be attached to the patient’s back so that normal suction cup electrodes cannot be used. Also, the pati-ent must be turned over in some cases and in an emergency it is often di� cult to use back electrodes. This complicates the exam pro-cedure. Synthesized 18-lead ECG uses the 12-lead ECG waveforms to mathematically derive the waveforms of the right chest leads (V3R, V4R, V5R) and back leads (V7, V8, V9).
Standard 12-lead ECG Synthesized 18-lead ECGSynthesized right side leads (V3R-V5R) andsynthesized back leads (V7-V9) are added
V1 V2 V3
V4
V5
V6syn-V5R
syn-V7
syn-V4R
syn-V3RV1 V2 V3
V4
V5
V6
syn-V8syn-V9
Version 08/2013; Subject to change without notice
Parameter Series TEC-8300 BSM-1700 PVM-2700 BSM-3000 BSM-6000 BSM-9100 BSM-2300
initial SW initial SW SW-V.03-30 SW V.04-12 SW V.04-12 SW-V.13-05 SW V.04-31
Flo Trac (APCO) – – – –
BISx Bispectral Index –with YJ-671P
–with YJ-671P with YJ-230P
BISx remarks – – – –via JA-69xP (DAU) via AUX port only
Dual SpO₂ (Second SpO2) – –via JA-69xP (DAU) –
IBP (Invasive Blood Pressure)only PVM-2703
CO (Cardiac Output) – – –EtCO₂ (Capnography)
with PVM-2703TEMP (Temperature) – – – –RESP (Respiration) – – – – –FiO₂ (Fraction of inspired oxygen) – – – – –
= Available – = N/A Defi brillator Patient Monitors
Current Products Older Products
www.nihonkohden.net8 www.nihonkohden.net8
Highest Safety and Quality Standards Comprehensive quality assurance systems ensure that each of the more than 4,000 NIHON KOHDEN sta� members makes his/her contribution towards development, manufacture, marketing and customer services such that maximum product quality is guaranteed.
NIHON KOHDEN is certifi ed according to ISO 9001, ISO 13485 and ISO 14001.
NIHON KOHDEN designs and manufactures medical equipment in conformity with the standards of IEC 60601-1 (Medical Electrical Equipment: General Requirements for Safety).
NIHON KOHDEN products have earned a reputation for quality and long life. One reason is that all export products and major components are manufactured in our own ISO 9001 and IEC 13485 certifi ed factories.
In 1984, NIHON KOHDEN implemented a comprehensive companywide quality system, IQC – Integrated Quality Control. Under this system, quality begins at the earliest stage of every product’s life. Our IQC applies to the entire manufacturing process, from the planning stage through product development, design, parts procurement, production, inspection, storage, sales, distribution and after-sales support. IQC also involves nearly every employee.
Our rigid test procedures are structured to exceed the provisions of the GMP, Good Manufacturing Practice, codes enforced by the US Food and Drug Administration. NIHON KOHDEN also has 130 in-house quality control inspection sta� to ensure that standards are implemented and maintained in every department of the company.
IQC extends beyond production and into sales and support at each subsidiary. This sta� is responsible for ongoing contact with customers to determine their needs and making sure that these changing requirements are refl ected in new products. Service engineers are responsible for communicating any problem that may arise in the use of NIHON KOHDEN products, and assuring the customers of NIHON KOHDEN’s commitment to their satisfaction.
In 1995, NIHON KOHDEN received ISO 9001 certifi cation, the international standard for quality systems. In addition, NIHON KOHDEN’s four manufacturing facilities in Japan are the fi rst factories in the medical equipment industry to be certifi ed by the CSA, Canadian Standards Association, under their category certifi cation system. Most products sent to North America carry the CSA label.
Quality improvement is and always has been an ongoing process for NIHON KOHDEN.
Convince yourself of our expertise and the high quality of our products and services! Order directly!
Highest Safety and Quality Standards
www.nihonkohden.net9 www.nihonkohden.net9 Quick Guide NIHON KOHDEN
ECG-2350 ECG-2550 ECG-1500/1550 ECG-1150 ECG-1250 ECG-1350
ECG-1950 ECG-9620 ECG-9320 ECG-9130/9132 ECG-9110 ECG-9020/9022
ECG-9010 ECG-8830 ECG-8820/8823 ECG-8420/8450 ECG-8350/8370 ECG-8330/8340
ECG-8240/8270 ECG-8110 ECG-6851
ELEC
TRO
CARD
IOG
RAPH
S
TEC-8321/8322/8332/ TEC-5521/5531 TEC-7721/7731 TEC-7621/7631 TEC-7511/7521/7531 TEC-7100/7200/7300 8342/8352
TEC-6100 TEC-2202/2203
DEF
IBRI
LLAT
ORS
Quick GuideElectrocardiographs, Defi brillators, AED/TRN
AED
/TRN
AED-2100 AED-2150/2151/2152 TRN-2100 TRN-2150
0
500
1000
1500
2000
2500
3000
Without ec1 With ec1
Number of false alarms
NIHON KOHDEN’s ec1 arrhythmia analysis provides superior elimination of false
alarms. ec1 has been evaluated with worlds standard arrhythmia databases as well as
NIHON KOHDEN’s ECG database, with a result of 80% reduction of false alarms.
Highly accurate ec1 arrhythmia analysis
ECG Measurement
Tachy
V. Rhythm
VPC Run
VT
Ext. Tachy
VF
www.nihonkohden.net11
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Cardiology › Typical Arrhythmia Waveforms
Lead C1
C2
C3
C4
C5
C6
Typical Arrhythmia Waveforms
Heart Anatomy
Nihon Kohden products which detect arrhythmia
Electrocardiographs / Defillibrators / Bedside Monitors
Diagnostic ECG Electrode Placement Cardiac Conduction SytemR and L electrodes should be placed just below the right and left clavicle. N and F electrodes should be placed on the lower edge of the rib cage, or at the level of the umbilicus at the mid-clavicular line.
Electrode PlacementFourth intercostal space at the right border of the sternum
Fourth intercostal space at the right border of the sternum
Midway between locations C2 and C4
At the mid-clavicular line in the fifth intercostal space
At the anterior axillary line on the same horizontal level as C4
At the mid-axillary line on the same horizontal level as C4 and C5
1. Inferior vena cava2. Superior vena cava3. Right atrium4. Tricuspid valve5. Right ventricle6. Pulmonary valve7. Pulmonary artery8. Pulmonary vein9. Left atrium10. Mitral valve11. Left ventricle12. Aortic valve13. Coronary artery 14. Aorta15. Brachiocephalic artery16. Left common carotid artery17. Left subclavian artery18. Descending aorta
SA nodeThe sinoatrial (SA) node generates a wave of electrical excitation.The excitation travels through the internodal pathways to the atria and the atrial muscles contract. This is recorded as the P-wave.The excitation travels to theatrioventricular (AV) node.The excitation then travels through the bundle of His and down through the right and left bundle branches.The excitation terminates at the Purkinje fibers in the ventricles and the ventricular muscles contract. This is the depolarization and is recorded as the QRS complex.The ventricular muscles relax. This is the repolarization and is recorded as the T- wave.
1
2
3
45
6
78
9
10
1112
13
14
15 16 17
18
778
C1 C2C3
F
C4 C5C6
N
R L
1 2
2
3
4
5
5
1
2
3
4
5
6
AV node
Rightbundlebranch
Purkinjefibers
Purkinjefibers
His bundle
Ventricles
Leftbundlebranch
Atria
Premature Ventricular Contractions (PVC)
• Premature contractions • Bizarre and wide QRS complexes • Full compensatory pause • Frequent PVCs are serious
• Fast pulse rate greater than 100 bpm • 3 or more irregular beats • Needs emergency treatment and countershock • May progress to
Ventricular Tachycardia (VT)
Multi- focal PVC Ventricular Fibrillation (VF)
• Multi form PVCs • Bizarre and wide QRS complexes • No discernable P-waves, R-waves, P-R rythm or QRS complexes • Needs emergency treatment and countershock
12
Short run PVC Second-degree atrioventricular (AV) block, Mobitz type II
• Sudden absence of QRS complexes (P-waves observed) • May progress to cardiac arrest • Possibillity of Adams-Stokes syndrome • Occasionally needs pacing
P P P
• Consecutive PVCs • May progress to ventricular tachycardia
Premature Supraventricular Contractions(Premature Atrial Contractions (PAC)) Atrial Fibrillation (AF)
• Narrow QRS (excluding aberrant ventriular conduction) • Ectopic focus higher than His-bundle • Non-compensatory pause
• Slight ripples on the baseline • Irregular R-R intervals • Inverted QRS complexes • Non-compensatory pause
P P
123.456
-------------
-------------
-------------------
-------------------
--------------------------
--------------------------
R-on-T PVC Third-degree (complete) atrioventricular (AV) block
• Independent development of P-waves and QRS complexes • Possibility of bradycardia • Possibility of Adams-Stokes syndrome • Needs pacing
• PVC on summit of T-wave • Bizarre and wide QRS complexes
P P P P P PP P P P P
P
Q S
T
R
ECG Cables
ECG 12/15-Lead Cable
ECG Veterinary 5-Lead Cable
Additional Cable Accessories
ECG 10-Lead Cable
www.nihonkohden.net13
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Electrocardiographs > ECG Cables
ECG 10-Lead CableSupply CodeK081
ModelBJ-902D
Description10-Lead ECG Patient Cable, 4 mm banana plug (IEC), limb 3.4 m/chest 2.9 mFor current products: ECG-1150/1250/1350/2350Packing unit: 1 pcs
K082 BJ-903D 10-Lead ECG Patient Cable, snap (IEC), limb 3.4 m/chest 2.9 mFor current products: ECG-1150/1250/1350/2350Packing unit: 1 pcs
K079 BJ-901D 10-Lead ECG Patient Cable, 3 mm banana plug (IEC), limb 1.2 m/chest 0.7 mFor current products: ECG-1150/1250/1350/2350Packing unit: 1 pcs
K093C BR-912D 10-Lead ECG Patient Cable, 4 mm banana plug (IEC), for input-box JC-901D, for resting ECG, limb 1.2 m/chest 0.7 mFor current products: ECG-1550Packing unit: 1 pcs
K093D BR-913D 10-Lead ECG Patient Cable, clip (IEC), for input-box JC-901D, for resting ECG, limb 1.2 m/chest 0.7 mFor current products: ECG-1550Packing unit: 1 pcs
K093F BR-913E 10-Lead ECG Patient Cable, clip (IEC), for input-box JC-901D, for stress test, limb/chest 0.6 mFor current products: ECG-1550Packing unit: 1 pcs
K096A 490933 Connection Cable for Patient Input-Box JC-901D, cable length: 2.0 mFor current products: ECG-1550Packing unit: 1 pcs
K096B 669269 Connection Cable for Patient Input-Box JC-901D, cable length: 5.0 mFor current products: ECG-1550Packing unit: 1 pcs
www.nihonkohden.net14
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Electrocardiographs > ECG Cables
ECG 12/15-Lead CableSupply CodeK093L
ModelBR-921D
Description15-Lead ECG Patient Cable, 3 mm banana plug (IEC), for input-box JC-901D, for stress test, limb/chest 1.2 mFor current products: ECG-1550Packing unit: 1 pcs
KB010 BR-202D 12-Lead Set (Electrode Leads: R,L,F,N,C1,C2,C3,C4,C5,C6), 4 mm banana plugFor current products: ECG-2550Packing unit: 1 pcs
KB012 BR-202D XYZ-Lead Set, 4 mm banana plugFor current products: ECG-2550Packing unit: 1 pcs
K118 Slide Clipper for ChestFor current products: ECG-2550Packing unit: 1 pcs
K119 Slide Clipper for LimbFor current products: ECG-2550Packing unit: 1 pcs
Supply Code Model Chest Lead Label Color Cable Length Cable Color For current products
Packing unit
KB01A BR-202D C1 redKB02A BR-202D C2 yellowKB03A BR-202D C3 greenKB04A BR-202D C4 brownKB05A BR-202D C5 blackKB06A BR-202D C6 violetKB07A BR-202D CX1KB08A BR-202D CX2KB09A BR-202D CX3KB10C red KB11C yellowKB12D green 1.4 mKB13B
1.0 mKB13D 1.4 mKB14B yellowKB15B redKB16B blueKB17B orangeKB18B brownKB19C white 1.2 m
white
white
ECG-2550
0.7 m
grey1.2 m
1.0 m white
1 pcs
black
www.nihonkohden.net15
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Electrocardiographs > ECG Cables
ECG Veterinary 5-Lead CableSupply Code K098
Model BJ-904D
Description 5-Lead Veterinary ECG Connection Cable, 3 mm banana plug (IEC) For current products: ECG-1950Packing unit: 1 pcs
Additional Cable AccessoriesSupply Code K097
ModelBM-901D
Description Adapter for ECG Vacuum Equipment with 15 PIN Sub-D Connector to input-box JC-901DFor current products: ECG-1500/1550Packing unit: 1 pcs
It is important to prepare the skin before attaching the electrodes
by cleaning it and removing chest hair. After this please attach
the lead wire to the electrodes before placing them on the skin.
This avoids pain to the patient. Secure the lead wire to the skin
(stress loop) preventing moving of the lead wire and therefore
noise on the ECG signal.
Standard Electrodes Placements
ECG Electrodes
Three electrodes Ten electrodes
Chest & Plate Electrodes
Tab Electrodes
Clip Electrodes
ECG Electrodes for Adults,Children, Infants & Neonates
ECG Electrode Adapter
www.nihonkohden.net17
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
FactsThe NIHON KOHDEN Fastclip ECG Electrodes allow a fl exible application for routine work and emergency on every paediatric and adult patient thanks to a simple adjustability of the clip pressure (clip size). A more comfortable handling is guaranteed due to di� erent con-nectors for any existing adapter type, a big contact area for reliable ECG measurements and easier cleaning after the measurement because of less asperity of the clip. In addition to this IEC colored label sets are delivered with NIHON KOHDEN Fastclip ECG Electrodes.
By following the next steps, optimized derivations can be realized with NIHON KOHDEN Fastclip ECG Electrodes:
1.) Clean the according skin areas with alcohol in order to remove traces of dirt and oil on the skin.2.) Apply a thin layer of CardioCream F010 on the cleaned skin areas and on the electrode part.3.) Clip the electrode on the wrist or ankle. Adjust the electrode positon by sliding the electrode part according to the thickness of the limb.
Supply Code H068A
Description Fastclip ECG Electrode, 3 mm, child/adult, blue, adjustable sizeFor current products: all ECG/EEGPacking unit: 4 pcs
H068B Fastclip ECG Electrode, 4 mm, child/adult, blue, adjustable sizeFor current products: all ECG/EEGPacking unit: 4 pcs
H072 Veterinary Clip Electrode, 3 mm, cable length: 0.3 m, for K098For current products: ECG-1950/9022Packing unit: 5 pcs
Any of tip, clip and snap type connector is available. Less asperity easy cleaning.
Three types of connectors available Easy cleaning
Opens more widly*, and roundform brings easy to grip. (*compared to the previous model)
Easy to handle
Contact pressure and position of elec-trodes section can be adjusted accor-ding to patients΄ conditions.
Adjustability
Tip SnapClipPrevious model New model
Raised dotsTrench shape
strongmiddle
weak
spring
wide
narrow
Electrocardiographs > ECG Electrodes
Clip Electrodes
www.nihonkohden.net18
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Chest & Plate ElectrodesSupply Code H041A
Model 6144-000427
Description Chest Suction Electrode, 3 mm, adult, size: 20 mm dia, grey rubber ballPacking unit: 3 pcs
H043A 6144-011852 Chest Suction Electrode, 4 mm, adult, size: 20 mm dia, grey rubber ballPacking unit: 3 pcs
H044A NC-124D Chest Suction Electrode Tako, 4 mm, child, size: 14 mm dia, pink octopus rubber ballPacking unit: 3 pcs
H044B NC-124D Chest Suction Electrode Kuma, 4 mm, child, size: 14 mm dia, blue bear rubber ball Packing unit: 3 pcs
H049 Grey Rubber Ball Set for Adult Suction Electrode H043APacking unit: 3 pcs
H052A Pink Octopus Rubber Ball Set for Children Suction Electrode H044APacking unit: 3 pcs
H052B Blue Bear Rubber Ball Set for Children Suction Electrode H044BPacking unit: 3 pcs
Electrocardiographs > ECG Electrodes
www.nihonkohden.net19
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Supply Code NKD-Z715
Description Plate Electrode, adult, size: 30 mm dia, suitable limb electrode straps, for NKD-Z722 Packing unit: 1 pcs
NKD-Z722 Rubber Strap, chest, size: 135 cm x 7 cm, black, 5 rows of holes, for plate electrode NKD-Z715Packing unit: 1 pcs
NKD-Z723 Attachment Button for Rubber Strap NKD-Z722Packing unit: 1 pcs
Tab ElectrodesSupply Code NKD-ECG/TAB1
Description ECG Tab Electrode Normal, Ag/AgCl, child/adult, radiolucent (X-ray, MRI), size: 26 x 34 mm, bio-solid gel, backing material: graphite, for resting ECGPacking unit: 500 pcs
NKD-ECG/TAB2 ECG Tab Electrode Small, Ag/AgCl, child, radiolucent (X-ray, MRI), size: 13 x 34 mm, bio-solid gel, backing material: graphite, for resting ECGPacking unit: 500 pcs
NKD-H/ADAPTER2 ECG Tab Electrode Clamps for NKD-ECG/TAB1 & NKD-ECG/TAB2, 4 mm banana plugPacking unit: 10 pcs
Electrocardiographs > ECG Electrodes
www.nihonkohden.net20
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
ECG Electrodes for AdultsNIHON KOHDEN VITRODE Disposable ECG Electrodes –
The result of over 30 years experience in disposable electrode manufacturing.
The ECG electrodes are the most important portions of the ECG/arrhythmia monitoring system. It is through these electrodes that the electrical signals are conducted from the patient and into the monitoring system. If the electrodes are left in place for an extended period of time (over 48 hours), or they are reused once they are removed, they do not adhere to the patient’s skin and they cause “noisy’’ ECG signals because of the poor conduction. In addition, the patient’s movement causes the electrodes to lose conducting capabilities intermittently, and this leads to a “wandering’’ ECG waveform and muscle artifact. The standard monitoring practice is to change these electrodes at least every 48 hours. Please contact us for individual offer based on your annual volume! Use the possibility of call orders!
Supply Code G203
ModelL-150
Description ECG Electrode Vitrode L, Ag/AgCl, adult, size: 35 mm dia, foam tape, solid gel, general usePacking unit: 5 x 30 pcs
G204 C-150 ECG Electrode Vitrode C, Ag/AgCl, adult, size: 47 mm dia, breathable cottony softcloth with an elastic quality for tension, solid gelPacking unit: 5 x 30 pcs
G207 L-150X ECG Electrode Vitrode L, Ag/AgCl, adult, size: 35 mm dia, radiolucent (X-ray), foam tape, solid gelPacking unit: 5 x 30 pcs
G210D F-150M ECG Electrode Vitrode F, Ag/AgCl, adult, size M: 25 x 45 mm, cotton tape especially for sensitive skin, adhesive gelPacking unit: 3 x 50 pcs
G236 M-150 ECG Electrode Vitrode M, Ag/AgCl, child/adult, size: 40 mm dia, foam tape, highbrid gel, for stress testPacking unit: 5 x 30 pcs
G250 J-150 ECG Electrode Vitrode J, Ag/AgCl, adult, size: 40 mm dia, foam tape, solid gel, excellent adhesion even on sweaty skinPacking unit: 5 x 30 pcs
Electrocardiographs > ECG Electrodes
www.nihonkohden.net21
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
ECG Electrodes for Children, Infants & NeonatesSupply Code G210C
ModelF-150S
Description ECG Electrode Vitrode F, Ag/AgCl, neonate/child, size S: 18 x 36 mm, cotton tape especially for sensitive skin, adhesive gelPacking unit: 3 x 50 pcs
ECG Electrode AdapterSupply Code N-00
Description Snap Adapter for Disposable ECG Electrodes, 4 mm dia plug to clip connectorPacking unit: 5 pcs
N-08 Clip Adapter for Disposable ECG Electrodes, 4 mm dia plug to snap connectorPacking unit: 10 pcs
Electrocardiographs > ECG Electrodes
ECG Batteries
www.nihonkohden.net23
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
ECG BatteriesSupply Code X065
Model NKB-301V
Description Battery Pack, 12V, 2800 mAh, nickel-metal hydride (NiMH), rechargeableFor current products: ECG-1350/2350/TEC-5500/7700Packing unit: 1 pcs
X071 SB-901D Battery Pack, 12V, 1950 mAh, nickel-metal hydride (NiMH), rechargeableFor current products: ECG-1150/1250/1950Packing unit: 1 pcs
X073 SB-150D Battery Pack, 12V, 3600 mAh, nickel-metal hydride (NiMH), rechargeableFor current products: ECG-1500/1550Packing unit: 1 pcs
X078 SB-201D Battery Pack, 14.4V, 3400 mAh, nickel-metal hydride (NiMH), rechargeableFor current products: ECG-2550Packing unit: 1 pcs
X040 LCS-2012NK Battery Pack, 12V, 2000 mAh, lead-acid, rechargeableFor old products: ECG-6000/OEC-8110Packing unit: 1 pcs
X041A LCT-1912ANK Battery Pack, 12V, 1900 mAh, lead-acid, rechargeableFor old products: ECG-9022/9132Packing unit: 1 pcs
X041B LC-S2912NK Battery Pack, 12V, 2900 mAh, lead-acid, rechargeableFor old products: ECG-9320/TEC-7500Packing unit: 1 pcs
Electrocardiographs > ECG Batteries
ECG Paper
www.nihonkohden.net25
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
ECG PaperSupply Code A052
Model FQW210-10-295
Description Thermal Paper, Z-fold, 210 mm x 100 m (page 295 mm), 339 pages, with queue mark/perforationFor old products: ECG-9320Packing unit: 10 pcs
A053 FQW210-30-295 Thermal Paper, Z-fold, 210 mm x 300 m (page 295 mm), 1017 pages, without grid, with queue mark/perforationFor current products: ECG-2550/1550 | For old products: ECG-9320Packing unit: 1 pcs
A128 RQS50-3 Thermal Paper, roll, 50 mm x 30 m, orange gridFor current products: TEC-8300For old products: ECG-6651/TEC-7100/7200/7300Packing unit: 10 pcs
A129 RQS63-3 Thermal Paper, roll, 63 mm x 30 m, with grid, without queue mark/perforationFor old products: ECG-1150Packing unit: 10 pcs
NKD-210-10/295 Thermal Paper, Z-fold, 210 mm x 100 m (page 295 mm), 339 pages, without grid, with queue mark/perforation, equivalent to A052 & NKD-210-10AFor old products: ECG-9320/old MEBPacking unit: 10 pcs
NKD-210-5-295 Thermal Paper, Z-fold, 210 mm x 50 m (page 295 mm), 169 pages, without grid, equivalent to A053For current products: ECG-2550/1550 | For old products: ECG-9320 Packing unit: 10 pcs
NKD-A054 Thermal Paper, Z-fold, 210 mm x 30 m (page 140 mm), 214 pages, without grid, with queue mark/perforationFor current products: ECG-1350/2350 | For old products: ECG-9132Packing unit: 10 pcs
NKD-A730 Thermal Paper, Z-fold, 110 mm x 20 m (page 140 mm), 143 pages, without grid, with queue mark/perforationFor current products: ECG-1250/1950 | For old products: ECG-9022Packing unit: 10 pcs
Electrocardiographs > ECG Paper
www.nihonkohden.net26
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Supply Code NKD-63
Description Thermal Paper, Z-fold, 63 mm x 30 m (page 75 mm), 400 pages, with grid, without queue mark/perforationFor old products: ECG-9620Packing unit: 10 pcs
NKD-A129 Thermal Paper, roll, 63 mm x 30 m, with grid, without queue mark/perforation, equivalent to A129For current products: ECG-1150 | For old products: ECG-9620Packing unit: 10 pcs
NKD-145-2,5 Thermal Paper, Z-fold, 145 mm x 25 m (page 100 mm), 85 pages, orange grid, equivalent to A036BFor old products: ECG-8400Packing unit: 10 pcs
NKD-145-6A300 Thermal Paper, roll, 145 mm x 60 m (page 300 mm), 200 pages, orange grid, equivalent to A132 but without queue mark/perforationFor old products: ECG-8821Packing unit: 10 pcs
NKD-A134A Thermal Paper, roll, 210 mm x 30 m, without grid/queue mark/perforationFor old products: ECG-9110/9130/9132Packing unit: 10 pcs
Electrocardiographs > ECG Paper
Additional ECG Accessories
www.nihonkohden.net28
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Additional ECG AccessoriesSupply Code F010
Model Z-101BC
Description “CardioCream” ECG Electrode Paste, 100 g tubePacking unit: 2 pcs
NKD-G711 Electrode Spray Gyrolux, skin preparation for use of suction vacuum pumps, 250 ml bottlePacking unit: 1 pcs
NKD-SD1GB Memory SD Card 1 GBPacking unit: 1 pcs
Y011 404617 Thermal Head Cleaner PenFor current products: all ECG/TEC/old MEB/EEG/allBSM/PVM/OPV/WEPPacking unit: 1 pcs
NKD-BAG Carrying Bag for ECG & AccessoriesFor current products: ECG-1150/1250/1350/1950/2350Packing unit: 1 pcs
NKD-L936 Power Cable, Schuko plug, cable length: 2.0 mPacking unit: 1 pcs
NKD-POWERLINE Multiple Power Socket (4 slots), medical certifi cationPacking unit: 1 pcs
Electrocardiographs > Additional ECG Accessories
www.nihonkohden.net29
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Supply Code K117A
Description Connection Cable for Input Box, cable length: 2.0 mFor current products: ECG-2550Packing unit: 1 pcs
K117B Connection Cable for Input Box, cable length: 5.0 mFor current products: ECG-2550Packing unit: 1 pcs
K117C Connection Cable for Input Box, cable length: 10.0 mFor current products: ECG-2550Packing unit: 1 pcs
Electrocardiographs > Additional ECG Accessories
Accessories for Defi brillators
Defi brillator Batteries & Battery Charger
www.nihonkohden.net32
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Defi brillators > Defi brillator Batteries & Battery Charger
Defi brillator Batteries & Battery ChargerSupply CodeX065
ModelNKB-301V
DescriptionBattery Pack, 12V, 2800 mAh, nickel-metal hydride (NiMH), rechargeableFor current products: TEC-5500/7700/ECG-1350 Packing unit: 1 pcs
X077 SB-831V Battery Pack, 14.4V, 6300 mAh, lithium-ion battery, rechargeableFor current products: TEC-8300Packing unit: 1 pcs
X041 LCT-1912NK-1 Battery Pack, 12V, 1900 mAh, lead-acid, rechargeableFor old products: TEC-7100/7200Packing unit: 1 pcs
X041B LC-S2912NK Battery Pack, 12V, 2900 mAh, lead-acid, rechargeableFor old products: ECG-9320/TEC-7500Packing unit: 1 pcs
X060A NKB-102V Battery Pack, 12V, 1700 mAh, nickel-cadmium (NiCd), rechargeableFor old products: TEC-8200Packing unit: 1 pcs
SB-801V External Dual Battery Charger, for 2x battery X077For current products: TEC-8300Packing unit: 1 pcs
SC-831V AC/DC Module for Series TEC-8300KFor current products: TEC-8300Packing unit: 1 pcs
SB-551V External Dual Battery Charger, for 2x battery X065For current products: TEC-5500/7700Packing unit: 1 pcs
Defi brillator Paper
www.nihonkohden.net34
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Defi brillators > Defi brillator Paper
Defi brillator PaperSupply CodeA128
ModelRQS50-3
DescriptionThermal Paper, roll, 50 mm x 30 m, orange gridFor current products: TEC-8300 | For old products: ECG-6651/TEC-7100/7200/7300Packing unit: 10 pcs
A222 FQS50-3-100 Thermal Paper, Z-fold, 50 mm x 30 m (page 100 mm), 300 pages, orange gridFor current products: TEC-7700Packing unit: 10 pcs
A226 FQS50-2-100 Thermal Paper, Z-fold, 50 mm x 20 m (page 100 mm), 200 pages, orange gridFor current products: TEC-5500/BSM-2300/3000Packing unit: 10 pcs
A238 PS50-2 Thermal Paper, roll, 50 mm x 20 m, orange grid, without queue mark/perforationFor old products: TEC-6600Packing unit: 10 pcs
NKD-A226 Thermal Paper, Z-fold, 50 mm x 20 m (page 100 mm), 200 pages, orange gridFor current products: TEC-5500Packing unit: 10 pcs
Defi brillator Bags
www.nihonkohden.net36
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Defi brillators > Defi brillator Bags
Defi brillator BagsSupply CodeNKD-DEFIBAG83
DescriptionSoftbag for Series TEC-8300K incl. Warning Sign Label Please indicate the specifi ed abbreviation letter for the required language when ordering: English (K), German (G), French (F), Italian (R), Spanish (E), Turkish (TR) or Russian (RU)! For current products: TEC-8300Packing unit: 1 pcs
NKD-STRAP83 Shoulder Strap for Series TEC-8300K SoftbagFor current products: TEC-8300Packing unit: 1 pcs
NKD-DEFIBAG2 Carrying Bag 2 with 2 Additional Attached Accessory BagsFor current products: TEC-7700Packing unit: 1 pcs
NKD-DEFIBAG3 Carrying Bag 3 with 1 Additional Attached Accessory BagFor current products: TEC-5500Packing unit: 1 pcs
NKD-DEFIBAG6 Accessory BagFor current products: TEC-5500/7700Packing unit: 1 pcs
Disposable Defi brillator Pads
Disposable Pads with NIHON KOHDEN Connector
Disposable Pads with R2 Connector
www.nihonkohden.net38
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Defi brillators > Disposable Defi brillator Pads
Disposable Pads with NIHON KOHDEN ConnectorSupply CodeH312
ModelP-513
DescriptionDefi brillation Pads with Outside Connector, infant (< 10 kg), for use with adapter cable JC-765V/K342B, weight: 80 g ± 10 g, size: 73 mm ± 8 mm x 110 mm ± 11 mm, conductive surface: 48.40 cm2 ± 10%, cable length: 1.5 mFor current products: TEC-5500/7700/8300Packing unit: 1 pair
H327 P-511 Defi brillation Pads with Outside Connector, child/adult (> 10 kg), for use with adapter cable JC-765V/K342B, weight: 90 g ± 15 g, size: 108 mm ± 10 mm x 159 mm ± 10 mm, conductive surface: 99 cm2 ± 10%, cable length: 1.5 mFor current products: TEC-5500/7700/8300Packing unit: 1 pair
K342B JC-865V Adapter Cable for Disposable Defi brillator Pads H312/H327/H324A, cable length: 3.5 mFor current products: TEC-8300Packing unit: 1 pcs
JC-765V Adapter Cable for Disposable Pads H312/H327/H324A, cable length: 3.5 mFor current products: TEC-5500/7700Packing unit: 1 pcs
Y206A AX-250V AED Cable Testing Unit for NIHON KOHDEN-Pads with Adapter Cable JC-765V/K342BFor current products: TEC-5500/7700/8300Packing unit: 1 pcs
www.nihonkohden.net39
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Defi brillators > Disposable Defi brillator Pads
Disposable Pads with R2 ConnectorSupply CodeNKD-H405
Model DescriptionDefi brillator Pads with Outside R2 Connector, adult, for use with adapter cable JC-755V/K342A, size: 159.93 cm², conductive surface: 114.75 cm², cable length: 1.28 mFor current products: TEC-5500/7700/8300Packing unit: 1 pair
NKD-H406 Defi brillator Pads with Outside R2 Connector, child, for use with adapter cable JC-755V/K342A, size: 78.13 cm², conductive surface: 53.80 cm², cable length: 1.28 mFor current products: TEC-5500/7700/8300Packing unit: 1 pair
K342A JC-855V Adapter Cable for Disposable Defi brillator Pads NKD-H405/NKD-H406 with R2 Connector, cable length: 3.5 mFor current products: TEC-8300Packing unit: 1 pcs
JC-755V Adapter Cable for Disposable Defi brillator Pads NKD-H405/NKD-H406 with R2 Connector, cable length: 3.5 mFor current products: TEC-5500/7700Packing unit: 1 pcs
Y206B AX-251V AED Cable Testing Unit for R2 Pads with Adapter Cable JC-755V/K342AFor current products: TEC-5500/7700/8300Packing unit: 1 pcs
Paddle Electrodes
Internal Paddle Electrode
Neonate Paddle Adapter
www.nihonkohden.net41
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Defi brillators > Paddle Electrodes
Internal Paddle Electrode with Discharge Button for Series TEC-8300
Supply CodeND-893V
DescriptionInternal Paddle Electrode with Discharge Button, including handle & electrode, size: 35 mm diaFor current products: TEC-8300Packing unit: 1 pair
ND-894V Internal Paddle Electrode with Discharge Button, including handle & electrode, size: 45 mm diaFor current products: TEC-8300Packing unit: 1 pair
ND-895V Internal Paddle Electrode with Discharge Button, including handle & electrode, size: 55 mm diaFor current products: TEC-8300Packing unit: 1 pair
ND-896V Internal Paddle Electrode with Discharge Button, including handle & electrode, size: 65 mm diaFor current products: TEC-8300Packing unit: 1 pair
ND-897V Internal Paddle Electrode with Discharge Button, including handle & electrode, size: 75 mm diaFor current products: TEC-8300Packing unit: 1 pair
www.nihonkohden.net42
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Defi brillators > Disposable Defi brillator Pads
Internal Paddle Electrode with Discharge Button for TEC-5500/7700
Supply CodeND-593V
DescriptionInternal Paddle Electrode with Discharge Button, including handle & electrode, size: 35 mm diaFor current products: TEC-5500/7700Packing unit: 1 pair
ND-594V Internal Paddle Electrode with Discharge Button, including handle & electrode, size: 45 mm diaFor current products: TEC-5500/7700Packing unit: 1 pair
ND-595V Internal Paddle Electrode with Discharge Button, including handle & electrode, size: 55 mm diaFor current products: TEC-5500/7700Packing unit: 1 pair
ND-596V Internal Paddle Electrode with Discharge Button, including handle & electrode, size: 65 mm diaFor current products: TEC-5500/7700Packing unit: 1 pair
ND-597V Internal Paddle Electrode with Discharge Button, including handle & electrode, size: 75 mm diaFor current products: TEC-5500/7700Packing unit: 1 pair
Neonate Paddle Adapter for TEC-5500/7700Supply CodeND-612V
DescriptionPaddle Adapter, neonate, size: 44 mm diaFor current products: TEC-5500/7700Packing unit: 1 pair
NIHON KOHDEN’s ec1 arrhythmia analysis provides superior elimination of false
alarms. ec1 has been evaluated with worlds standard arrhythmia databases as well as
NIHON KOHDEN’s ECG database, with a result of 80% reduction of false alarms.
Some functions are limited on series TEC-8300K. Contact your NIHON KOHDEN repre-
sentative for details.
Highly accurate ec1 arrhythmia analysis
ECG Measurement
0
500
1000
1500
2000
2500
3000
Without ec1 With ec1
Number of false alarms
Tachy
V. Rhythm
VPC Run
VT
Ext. Tachy
VF
www.nihonkohden.net44
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Lead C1
C2
C3
C4
C5
C6
Typical Arrhythmia Waveforms
Heart Anatomy
Nihon Kohden products which detect arrhythmia
Electrocardiographs / Defillibrators / Bedside Monitors
Diagnostic ECG Electrode Placement Cardiac Conduction SytemR and L electrodes should be placed just below the right and left clavicle. N and F electrodes should be placed on the lower edge of the rib cage, or at the level of the umbilicus at the mid-clavicular line.
Electrode PlacementFourth intercostal space at the right border of the sternum
Fourth intercostal space at the right border of the sternum
Midway between locations C2 and C4
At the mid-clavicular line in the fifth intercostal space
At the anterior axillary line on the same horizontal level as C4
At the mid-axillary line on the same horizontal level as C4 and C5
1. Inferior vena cava2. Superior vena cava3. Right atrium4. Tricuspid valve5. Right ventricle6. Pulmonary valve7. Pulmonary artery8. Pulmonary vein9. Left atrium10. Mitral valve11. Left ventricle12. Aortic valve13. Coronary artery 14. Aorta15. Brachiocephalic artery16. Left common carotid artery17. Left subclavian artery18. Descending aorta
SA nodeThe sinoatrial (SA) node generates a wave of electrical excitation.The excitation travels through the internodal pathways to the atria and the atrial muscles contract. This is recorded as the P-wave.The excitation travels to theatrioventricular (AV) node.The excitation then travels through the bundle of His and down through the right and left bundle branches.The excitation terminates at the Purkinje fibers in the ventricles and the ventricular muscles contract. This is the depolarization and is recorded as the QRS complex.The ventricular muscles relax. This is the repolarization and is recorded as the T- wave.
1
2
3
45
6
78
9
10
1112
13
14
15 16 17
18
778
C1 C2C3
F
C4 C5C6
N
R L
1 2
2
3
4
5
5
1
2
3
4
5
6
AV node
Rightbundlebranch
Purkinjefibers
Purkinjefibers
His bundle
Ventricles
Leftbundlebranch
Atria
Premature Ventricular Contractions (PVC)
• Premature contractions • Bizarre and wide QRS complexes • Full compensatory pause • Frequent PVCs are serious
• Fast pulse rate greater than 100 bpm • 3 or more irregular beats • Needs emergency treatment and countershock • May progress to
Ventricular Tachycardia (VT)
Multi- focal PVC Ventricular Fibrillation (VF)
• Multi form PVCs • Bizarre and wide QRS complexes • No discernable P-waves, R-waves, P-R rythm or QRS complexes • Needs emergency treatment and countershock
12
Short run PVC Second-degree atrioventricular (AV) block, Mobitz type II
• Sudden absence of QRS complexes (P-waves observed) • May progress to cardiac arrest • Possibillity of Adams-Stokes syndrome • Occasionally needs pacing
P P P
• Consecutive PVCs • May progress to ventricular tachycardia
Premature Supraventricular Contractions(Premature Atrial Contractions (PAC)) Atrial Fibrillation (AF)
• Narrow QRS (excluding aberrant ventriular conduction) • Ectopic focus higher than His-bundle • Non-compensatory pause
• Slight ripples on the baseline • Irregular R-R intervals • Inverted QRS complexes • Non-compensatory pause
P P
123.456
-------------
-------------
-------------------
-------------------
--------------------------
--------------------------
R-on-T PVC Third-degree (complete) atrioventricular (AV) block
• Independent development of P-waves and QRS complexes • Possibility of bradycardia • Possibility of Adams-Stokes syndrome • Needs pacing
• PVC on summit of T-wave • Bizarre and wide QRS complexes
P P P P P PP P P P P
P
Q S
T
R
Cardiology › Typical Arrhythmia Waveforms
ECG Cables
ECG Cables for TEC-8300
ECG 3/6-Lead Cables
ECG 10-Lead Cables
www.nihonkohden.net47
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Defi brillators > ECG Measurement
ECG 3/6-Lead Cables
V4V4 V5
6-lead ECG measurementPowerful ECG measurement96 % of an ischaemia change can be detected by 6 electrodes (II, V4, V5)
ST Change Detection Report• Only with I lead symbol 33%• Only with V5 lead symbol 75%
• II + V5 lead symbol 80%• II + V5 + V4 lead symbol 96%More accurate ischaemia detection
Supply Code6124-039432
Model DescriptionConnection Cable Cover for DIN Type Electrodes for K922For current products: TEC-8300/all BSM/PVM; ZS-910/920/930/940/530PG;ZM-920/930/940PGPacking unit: 1 pcs
K120 NA-0003 Electrode Lead Tube for K911/K910AFor current products: TEC-8300/5500/7700/all BSM/PVM; ZS-910/920/930/940/530PG; ZM-920/930/940PGPacking unit: 5 pcs
K910A BR-913P 3-Lead ECG Electrode Cable, clip, cable length: 0.8 m TEC-55/7700: for connection to defi brillators L153 is required BSM/PVM/TEC-8300: for connection to monitors K922 is requiredFor current products: TEC-8300/5500/7700/all BSM/PVM; ZS-910/920/930/940/530PG; ZM-920/930/940PGPacking unit: 1 pcs
K911 BR-903P 3-Lead ECG Electrode Cable, snap, cable length: 0.8 mTEC-55/7700: for connection to defi brillators L153 is requiredBSM/PVM/TEC-8300: for connection to monitors K922 is requiredFor current products: TEC-8300/5500/7700/all BSM/PVM; ZS-910/920/930/940/530PG; ZM-920/930/940PGPacking unit: 1 pcs
K913A BR-906V 6-Lead ECG Electrode Cable, clip, cable length: 0.6 mFor current products: TEC-8300/all BSM/PVM; ZS-910/920/930/940/530PG; ZM-920/930/940PGPacking unit: 1 pcs
K912 BR-906P 6-Lead ECG Electrode Cable, clip, cable length: 0.8m requires K922For current products: TEC-8300/all BSM/PVM; ZM-920/930/940PGPacking unit: 1 pcs
www.nihonkohden.net48
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Defi brillators > ECG Measurement
Supply CodeK915
ModelBR-916P
Description6-Lead ECG Electrode Cable, snap, cable length: 0.8m,requires K922For current products: all BSM/PVM/TEC-8300; ZM-920/930/940PGPacking unit: 1 pcs
K922 JC-906P 3/6-Lead ECG Connection Cable for K910A/K911/K912/K915 to patient monitors/defi brillator, cable length: 3.0 mFor current products: TEC-8300/all BSM/PVM; ZS-910/920/930/940/530PG; ZM-920/930/940PGPacking unit: 1 pcs
ECG 10-Lead CablesSupply CodeK901
ModelBJ-900P
Description 10-Lead ECG Patient Cable (12 channel ECG), clip, cable length: 3.8 m, incl. patient electrode lead & connection cableFor current products: BSM-1700/3000/5100/6000/9100/TEC-8300Packing unit: 1 pcs
K354 BJ-831V 10-Lead ECG Patient Cable (12 channel ECG), clip, cable length: 2.5 mFor current products: TEC-8300Packing unit: 1 pcs
ECG Cables for TEC-5500 & TEC-7700
ECG 3-Lead Cables
ECG 5-Lead Cables
Additional Defi brillator Connection Cables
www.nihonkohden.net50
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Defi brillators > ECG Measurement
ECG 3-Lead CablesSupply CodeK120
ModelNA-0003
DescriptionElectrode Lead Tube, for K911/K910AFor current products: TEC-5500/7700/8300/all BSM/PVM; ZS-910/920/930/940/530PG; ZM-920/930/940PGPacking unit: 5 pcs
K910A BR-913P 3-Lead ECG Electrode Cable, clip, cable length: 0.8 mTEC-5500/7700: for connection to defi brillators L153 is requiredBSM/PVM/TEC-8300: for connection to monitors K922 is requiredFor current products: TEC-5500/7700/8300/all BSM/PVM; ZS-910/920/930/940/530PG; ZM-920/930/940PGPacking unit: 1 pcs
K911 BR-903P 3-Lead ECG Electrode Cable, snap, cable length: 0.8 mTEC-5500/7700: for connection to defi brillators L153 is requiredBSM/PVM/TEC-8300: for connection to monitors K922 is requiredFor current products: TEC-5500/7700/8300/all BSM/PVM; ZS-910/920/930/940/530PG; ZM-920/930/940PGPacking unit: 1 pcs
K225 BR-018P 3-Lead ECG Connection Cable (IEC), clip, cable length: 0.8 m, for use with L152For current products: TEC-5500/7700Packing unit: 1 pcs
K226 BR-019P 3-Lead ECG Connection Cable (IEC), snap, cable length: 0.8 m, for use with L152For current products: TEC-5500/7700Packing unit: 1 pcs
K336 JC-005P Connection Cable (IEC), cable length: 3.0 m, for ECG Electrode LeadK225/K226/K227/K228For current products: TEC-5500/7700Packing unit: 1 pcs
K352A BC-763VA 3-Lead ECG Connection Cable (AHA), snap, cable length: 3.5 mFor current products: TEC-5500/7700Packing unit: 1 pcs
K353A BC-763V 3-Lead ECG Connection Cable (IEC), snap, cable length: 3.5 mFor current products: TEC-5500/7700Packing unit: 1 pcs
www.nihonkohden.net51
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Defi brillators > ECG Measurement
ECG 5-Lead CablesSupply CodeK227
ModelBR-020P
Description5-Lead ECG Connection Cable (IEC), clip, cable length: 0.8 m, for use with L152For current products: TEC-5500/7700Packing unit: 1 pcs
K228 BR-021P 5-Lead ECG Connection Cable (IEC), snap, cable length: 0.8 m, for use with L152For current products: TEC-5500/7700Packing unit: 1 pcs
K336 JC-005P Connection Cable (IEC), cable length: 3.0 m, for ECG Electrode LeadK225/K226/K227/K228For old products: TEC-8250/8251Packing unit: 1 pcs
K352B BC-765VA 5-Lead ECG Connection Cable (AHA), clip, cable length: 3.5 mFor current products: TEC-5500/7700Packing unit: 1 pcs
K353B BC-765V 5-Lead ECG Connection Cable (IEC), clip, cable length: 3.5 mFor current products: TEC-5500/7700Packing unit: 1 pcs
www.nihonkohden.net52
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Defi brillators > ECG Measurement
Further Defi brillator Connection CablesSupply CodeK232
ModelBR-002P
Description3-Lead ECG Connection Cable (IEC), clip, cable length: 0.8 mFor old products: TEC-7000Packing unit: 1 pcs
K350A BC-753V 3-Lead ECG Connection Cable (IEC), clip, cable length: 3.5 mFor old products: TEC-7500Packing unit: 1 pcs
K234 BR-004P 5-Lead ECG Connection Cable (IEC), clip, cable length: 0.8 mFor old products: TEC-7000Packing unit: 1 pcs
K332 JC-002P Connection Cable (IEC) for ECG Electrode Lead K234, cable length: 3.0mFor old products: TEC-7000Packing unit: 1 pcs
K351A BC-755V 5-Lead ECG Connection Cable (IEC), clip, cable length: 3.5 mFor old products: TEC-7500Packing unit: 1 pcs
L151 JC-761V External ECG Input Cable, connection to patient monitors, cable length: 2.9 mFor current products: TEC-5500/7700Packing unit: 1 pcs
L152 JC-762V External Defi brillator Connection Cable, cable length: 3.0 m, for ECG Electrode Lead K225/K226/K227/K228For current products: TEC-5500/7700Packing unit: 1 pcs
L153 JC-763V External Defi brillator Connection Cable, cable length: 3.0 m, for ECG Electrode Lead K910A/K911For current products: TEC-5500/7700Packing unit: 1 pcs
NIHON KOHDEN Vitrode Disposable ECG Electrodes –
The result of over 30 years experience in disposable electrode manufacturing.
The ECG electrodes are the most important portions of the ECG/arrhythmia monitoring system. It is through these electrodes that
the electrical signals are conducted from the patient and into the monitoring system. If the electrodes are left in place for an exten-
ded period of time (over 48 hours), or they are reused once they are removed, they do not adhere to the patient’s skin and they cause
“noisy’’ ECG signals because of the poor conduction. In addition, the patient’s movement causes the electrodes to lose conducting
capabilities intermittently, and this leads to a “wandering’’ ECG waveform and muscle artifact. The standard monitoring practice is
to change these electrodes at least every 48 hours.
Please contact us for individual o� er based on your annual volume! Use the possibility of call orders!
ECG Electrodes for Defi brillators
Standard Electrodes PlacementsIt is important to prepare the skin before attaching
the electrodes by cleaning it and removing chest
hair. After this please attach the lead wire to the
electrodes before placing them on the skin. This
avoids pain to the patient. Secure the lead wire to
the skin (stress loop) preventing moving of the
lead wire and therefore noise on the ECG signal.
ECG Electrodes for Adults
ECG Electrodes for Children,Infants & Neonates
Three electrodes Ten electrodesSix electrodes
www.nihonkohden.net54
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
ECG Electrodes for AdultsSupply CodeG203
ModelL-150
DescriptionECG Electrode Vitrode L, Ag/AgCl, adult, size: 35 mm dia, foam tape, solid gel, general usePacking unit: 5 x 30 pcs
G204 C-150 ECG Electrode Vitrode C, Ag/AgCl, adult, size: 47 mm dia, breathable cottony soft-cloth with an elastic quality for tension, solid gelPacking unit: 5 x 30 pcs
G207 L-150X ECG Electrode Vitrode L, Ag/AgCl, adult, size: 35 mm dia, radiolucent (X-ray), foam tape, solid gelPacking unit: 5 x 30 pcs
G210D F-150M ECG Electrode Vitrode F, Ag/AgCl, adult, size M: 25 x 45 mm, cotton tape especially for sensitive skin, adhesive gelPacking unit: 3 x 50 pcs
G250 J-150 ECG Electrode Vitrode J, Ag/AgCl, adult, size: 40 mm dia, foam tape, solid gel, excellent adhesion even on sweaty skinPacking unit: 5 x 30 pcs
G272A V-09OM3 ECG Electrode Vitrode V, Ag/AgCl, child/adult, size: 25 x 45 mm, cable length: 1.0 m, radiolucent (X-ray), hydrogel, foam & cotton tape, 3 pre-wired electrodes with 1.5 mm touch proof connectorPacking unit: 30 x 3 pcs
G272B V-040M4 ECG Electrode Vitrode V, Ag/AgCl, child/adult, size: 25 x 45 mm, cable length: 1.0 m, radiolucent (X-ray), hydrogel, foam & cotton tape, 4 pre-wired electrodes with 1.5 mm touch proof connector for limb leadsPacking unit: 10 x 4 pcs
Defi brillators > ECG Measurement
www.nihonkohden.net55
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Defi brillators > ECG Measurement
Supply CodeG272C
ModelV-06OM6
DescriptionECG Electrode Vitrode V, Ag/AgCl, child/adult, size: 25 x 45 mm, cable length: 1.0 m, radiolucent (X-ray), hydrogel, foam & cotton tape, 6 pre-wired electrodes with 1.5 mm touch proof connector for chest leadsPacking unit: 10 x 6 pcs
G278A V-09IO3 ECG Electrode Vitrode V, Ag/AgCl, child/adult, size: 25 x 45 mm, cable length: 1.5 m, radiolucent (X-ray), foam tape, 3 pre-wired electrodes with 1.5 mm touch proof connectorPacking unit: 30 x 3 pcs
ECG Electrodes for Children, Infants & NeonatesSupply CodeG210C
ModelF-150S
DescriptionECG Electrode Vitrode F, Ag/AgCl, neonate/child, size S: 18 x 36 mm, cotton tape especially for sensitive skin, adhesive gelPacking unit: 3 x 50 pcs
G271A V-120S3 ECG Electrode Vitrode V, Ag/AgCl, neonate/infant, without motif print, size: 20 mm dia, cable length: 0.6 m, radiolucent (X-ray), foam & cotton tape, 3 pre-wired electrodes with 1.5 mm touch proof connectorPacking unit: 40 x 3 pcs
A Pulse Oximeter is a non-invasive device used to percutaneously measure oxygen saturation
in the blood by use of a clip-on fi nger probe. Pulse oximeter works with the integration of a
probe placed onto patient’s fi ngertip or toe, obtains signals from the probe and the main
device calculates oxygen saturation in the body.
Oxygen saturation measured by a Pulse Oximeter is SpO2. “P” stands for “pulse”, and the
measurement principle is based on beat-by-beat changes in blood volume. In general, arteri-
al oxygen saturation measured by spectroscopic analysis is called “SaO2”, and oxygen satura-
tion measured by pulse oximeter is called “SpO2”.
The method for determination of arterial oxygen saturation, based on the photoelectric ple-
thysmography, was conceptualised and implemented in 1972 by the Japanese bio-engineer
Takuo Aoyagi (NIHON KOHDEN Corporation). This idea came about while using an ear den-
sitometer for recording dilution curves for dyes (pigments). The fi rst commercial oximeter
“OLV-5100” was presented by NIHON KOHDEN back in 1975.
Dr. Aoyagi’s innovative technology, pulse oximetry, has rapidly spread worldwide and become essential in critical care. In
2002, Dr. Aoyagi was awarded the Medal of Honor in Japan, in recognition of his great contribution to clinical medicine.
The NIHON KOHDEN SpO₂ Sensors of the BluPRO® Series are at the cutting edge of this progressive technology.
SpO₂ Measurement
Disposable
SpO2 Cables
www.nihonkohden.net58
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Defi brillators > SpO2 Measurement
SpO2 CablesSupply CodeK931
ModelJL-900P
DescriptionSpO2 Connection Cable, cable length: 2.5 m, rectangular connectorFor current products: TEC-8300/all BSM/PVM/PSG-1100Packing unit: 1 pcs
Y095A JL-550T2 SpO2 Connection Cable, cable length: 2.5 m, round connectorFor current products: TEC-5500/7700/JE-912A/921A/921AGPacking unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
NoteSpO2 measurement starts when the SpO2 connection cable and SpO2 probe are connected to the device, and the SpO2 probe is attached to the patient.
When not measuring SpO2, disconnect the SpO2 connection cable from the device. Otherwise, noise from the probe sensor may interfere and incorrect data is displayed on the screen.
Reusable SpO2 Probes
Disposable SpO2 Probes
BluPRO® SpO₂ Probes – A Unique Sensing Technology
Reliability and high quality of our probes provide a continuous accurate and safe monitoring with highest patient
comfort. The comfortable, sure fi tting and lightweight characteristic reduces the e� ect of hand movement for
highly reliable SpO2 measurement.
This ensures patient safety, reduces the costs of care and increases therefore clinical e� ciency and cost
e� ectiveness. NIHON KOHDEN BluPRO® SpO2 Probes are comfortable, durable, accurate and needs-oriented.
Note that accurate and safe measurement is assured only when you use probes, connection cords and parts manu-
factured by NIHON KOHDEN. Some probes in the market may advertise as „compatible with NIHON KOHDEN
probes.“ We strongly recommend you to avoid these probes as a correct measurement cannot be guaranteed on
NIHON KOHDEN devices. NIHON KOHDEN is not responsible for problems caused by using other manufacturer’s probes.
Please contact us for an individual o� er based on your annual volume! Use the possibility of call orders!
SpO₂ Probes
www.nihonkohden.net60 www.nihonkohden.net60 Defi brillators > SpO₂ Measurement
SpO₂ Probes
Low birth weight
Neonate Infant Child Adult
2 kg 3 kg1000 g 30 kg10 kg 20 kg 40 kg 50 kg
Dis
posa
ble
Reus
able
P204F (TL-272T3)
P203C (TL-273T)
P203D (TL-274T)
P204C (TL-273T)
P204D (TL-274T)
P228A (TL-051S)
P229A (TL-061S)
P225F (TL-201T)
P204G (TL-273T3)
P204H (TL-274T3)
P228B (TL-052S)
P229B (TL-062S)
P225H (TL-201T1)
P225G (TL-220T)
P203G (TL-273T3)
P203H (TL-274T3)
P204B (TL-272T)
P203E (TL-271T3)
P203A (TL-271T)
P204E (TL-271T3)
P203F (TL-272T3)
P204A (TL-271T)
P203B (TL-272T)
Supply Code (Model)
Cable length (m)
Packing unit
1.6
0.8
0.8
0.8
0.8
0.8
0.8
1.6
1.6
1.6
1.6
1.6
0.6
1.6
1.6
1.6
0.8
1.6
0.8
1.6
1.6
0.8
0.8
24
5
5
5
24
5
24
5
24
5
P310C (TL-630T3) 1.6
P311C (TL-631T3) 1.6
1
www.nihonkohden.net61
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Defi brillators > SpO2 Measurement
Reusable SpO2 Probes
FactsNIHON KOHDEN reusable SpO2 fi nger-clips probes have parallel mounted upper and lower sensor shells, thus, providing an exact alignment of the op-tical sensor components and markedly enhanced comfort during long-term attachment. In addition, fl exible lateral fl aps shield the measuring signals from the external light, thus resulting to minimize the interference by additional artifi cial light sources! Bright LEDs provide more accurate measure-ment even for thicker fi ngers or dark skin tones. The fi nger-clip reusable probe is the most popular type of SpO2 probes. Instead of the typical hinge near the fi nger tip, P225F/P225H have a unique sure fi tting and comfortable mechanism using two sliding pieces for the front and back of the fi nger with two rubber fl aps along both sides of the fi nger. When you press the button, the two halves of the probe slide directly open, parallel to each other. No additional fi xation tape is needed. For a stable and comfortable measurement P225F/P225H, always keep the light emitters and detector aligned. NIHON KOHDEN provides unique reusable SpO2 probes.
Supply CodeP225F
ModelTL-201T
DescriptionSpO2 BluPRO® Finger-Clip Probe, child/adult (> 20 kg) finger, cable length: 1.6 m, reusableFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 1 pcs
P225H TL-201T1 SpO2 BluPRO® Finger-Clip Probe, child/adult (> 20 kg) finger, cable length: 0.6 m, reusableFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 1 pcs
FactsThe multi-site probe P225G can be used for neonatal feet as well as adult fi ngers as its curved contact surface is designed to fi t on di� erent attachment sites. The light emitter and detector are separate which allows especially an accurate alignment of the LED on the infant/neonatal instep. A unique sliding adjuster gives the best fi t on the attachment site secured by taping.
Supply CodeP225G
ModelTL-220T
Description SpO2 BluPRO® Multi-Site Probe, neonate (< 3 kg) instep,child/adult ( > 3 kg) fi nger/toe, cable length: 1.6 m, reusableFor current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PGPacking unit: 1 pcs
Reusable, but always clean – NIHON KOHDEN washable probes.
The reusable probes of the BluPRO® series are durable and washable, so you can clean them under running water or even immerse them in a soapy alkaline or disinfectant solution (glutaraldehyde solution 2.0 % or hydrochloric alkyl diaminoethylene glycine 0.5 %)! P225F / P225H P225G
Durable, washable, demand-oriented!P310C / P311C
www.nihonkohden.net62
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Facts Our special designed fi nger-tip probes, P310C and P311C, fi t immediately on the fi nger and are perfect for long-term measurement. A less covered fi nger area and cushioned materials lead to decrease pressure to the attachment site. The 3D molding attachment ensures a comfortable fi t. In combination with the soft and lightweight design the patient stress or discomfort is reduced and the probes can be remained up to 8 hours to one attachment site. A stable measurement is assured by gentle fi xation tapes P263 or P267 that avoid the falling o� of the probes and reduce artifact from cable movement.Reusable but with the comfort of a disposable probe, P310C and P311C are also applicable for sleep studies, for patients that are often bending their fi ngers or obese patients.
Supply CodeP310C
ModelTL-630T3
Description SpO2 BluPRO® Finger-Tip Probe L, child/adult (> 50 kg) fi nger, cable length: 1.6 m, long-term use, reusableFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 1 pcs
P311C TL-631T3 SpO2 BluPRO® Finger-Tip Probe M, child/adult (> 20 kg) fi nger, cable length: 1.6 m, long-term use, reusableFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 1 pcs
P263 Disposable Probe Cable Fixing Tape for P310C/P311C, size: 15 x 130 mmFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 3 x 30 pcs
P267 YS-093P2 Disposable Probe Fastener Tape for P310C/P311C,size: 15 x 140 mmFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 30 pcs
Defi brillators > SpO2 Measurement
www.nihonkohden.net63
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Disposable SpO2 Probes NIHON KOHDEN disposable probes, from neonate to adult sizes, place special emphasis on the exact positioning of the LEDs and detector. For this reason the two optical components are designed separately and can thus be brought into precise alignment with each other by the user. All probes have breathable material and can be remained up to 8 hours on one attachment site. Paediatric probes have a cute cartoon character printed on the tape to reassure children.
Self-adhesive, soft and thin tape provides a secure fi t. The special design allows an easy application to the attachment site. To get the most comfortable fi t, please bend the probe before attaching, do not strongly pull the attachment tape when attaching and do not push the tip of the fi nger with the attachment tape.
Disposable SpO2 Probes 24 pcs/box – cable length: 0.8 m
Supply CodeP203A
ModelTL-271T
Description SpO2 BluPRO® Probe, adult (> 30 kg) fi nger/toe, cable length: 0.8 mFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 24 pcs
P203B TL-272T SpO2 BluPRO® Probe, child (10 – 50 kg) fi nger/toe, cable length: 0.8 mFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 24 pcs
P203C TL-273T SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 40 kg) fi nger/toe, cable length: 0.8 m, disposableFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 24 pcs
P203D TL-274T SpO2 BluPRO® Probe, infant (3 – 20 kg) fi nger/toe, cable length: 0.8 mFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 24 pcs
Defi brillators > SpO2 Measurement
www.nihonkohden.net64
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Disposable SpO2 Probes 24 pcs/box – cable length: 1.6 m
Supply CodeP203E
ModelTL-271T3
Description SpO2 BluPRO® Probe, adult (> 30 kg) fi nger/toe, cable length: 1.6 mFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 24 pcs
P203F TL-272T3 SpO2 BluPRO® Probe, child ( 10 – 50 kg) fi nger/toe, cable length: 1.6 mFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 24 pcs
P203G TL-273T3 SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 40 kg) fi nger/toe, cable length: 1.6 mFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 24 pcs
P203H TL-274T3 SpO2 BluPRO® Probe, infant (3 – 20 kg) fi nger/toe, cable length: 1.6 mFor current products:all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 24 pcs
Disposable SpO2 Probes 5 pcs/box – cable length: 0.8 m
Supply CodeP204A
ModelTL-271T
Description SpO2 BluPRO® Probe, adult (> 30 kg) fi nger/toe, cable length: 0.8 mFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 5 pcs
P204B TL-272T SpO2 BluPRO® Probe, child (10 – 50 kg) fi nger/toe, cable length: 0.8 mFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 5 pcs
Defi brillators > SpO2 Measurement
www.nihonkohden.net65
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Supply CodeP204C
ModelTL-273T
Description SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 40 kg) fi nger/toe, cable length: 0.8 mFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 5 pcs
P204D TL-274T SpO2 BluPRO® Probe, infant ( 3 –20 kg) fi nger/toe, cable length: 0.8 m For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 5 pcs
FactsAbsolutely cost-e� ective, the series P228 and P229 are intended for long-term measurement on a single patient. The probes do not need to be replaced with a new one before 96 hours by changing the attachment site every 8 hours. So your running costs can be reduced!The light emitter and detector are covered by sponge and the entire attachment site has a fl at surface. This reduces the risk of skin burn and irritation. Since the probe itself is not self-adhesive, you can easily remove and attach the probe to change the attached fi nger. For fi xation, wrap the probe around the fi nger with attachment tape P259.
Supply CodeP228A
ModelTL-051S
Description SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 50 kg) fi nger, cable length: 0.8 mFor current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PGPacking unit: 5 pcs
P229A TL-061S SpO2 BluPRO® Probe, infant/child (3 – 15 kg) toe, child (15 – 50 kg) fi nger, cable length: 0.8 mFor current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PGPacking unit: 5 pcs
P259 COTTONY Tape for fi xing disposable SpO2 ProbesFor current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PGPacking unit: 20 pcs
Defi brillators > SpO2 Measurement
www.nihonkohden.net66
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Disposable SpO2 Probes 5 pcs/box – cable length: 1.6 m
Supply CodeP204E
ModelTL-271T3
DescriptionSpO2 BluPRO® Probe, adult (> 30 kg) fi nger/toe, cable length: 1.6 mFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 5 pcs
P204F TL-272T3 SpO2 BluPRO® Probe, child (10 – 50 kg) fi nger/toe, cable length: 1.6 mFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 5 pcs
P204G TL-273T3 SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 40 kg) fi nger/toe, cable length: 1.6 mFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 5 pcs
P204H TL-274T3 SpO2 BluPRO® Probe, infant (3 – 20 kg) fi nger/toe, cable length: 1.6 mFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 5 pcs
Defi brillators > SpO2 Measurement
www.nihonkohden.net67
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
FactsAbsolutely cost-e� ective, the series P228 and P229 are intended for long-term measurement on a single patient. The probes do not need to be replaced with a new one before 96 hours by changing the attachment site every 8 hours. So your running costs can be reduced! The light emitter and detector are covered by sponge and the entire attachment site has a fl at surface. This reduces the risk of skin burn and irritation. Since the probe itself is not self-adhesive, you can easily remove and attach the probe to change the attached fi nger. For fi xation, wrap the probe around the fi nger with attachment tape P259.
Supply CodeP228B
ModelTL-052S
Description SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 50 kg) fi nger, cable length: 1.6 m, disposableFor current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PGPacking unit: 5 pcs
P229B TL-062S SpO2 BluPRO® Probe, infant/child (3 – 15 kg) toe, child (15 – 50 kg) fi nger, cable length: 1.6 m, disposableFor current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PGPacking unit: 5 pcs
P259 COTTONY Tape for fi xing disposable SpO2 Probes, disposableFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 20 pcs
Handling of the probe a� ects measurement accuracy and patient safetyFor the proper placement of the probe on the fi nger, it is advisable that the light emitter and detector are placed just opposite to each other. When using a fi nger clip probe, it is necessary to ensure that the probe covers the fi nger properly, otherwise some portion of the light never passes through the body tissues and may reach the light-receiving part directly, leading to incorrect measurement results.
The more distant the light emitter and detector gets, the weaker the transmitted light intensity becomes. Additionally, a thinner body part tends to have small amount of blood, which makes it di� cult to extract the arterial blood signal component. The most suitable thickness of the probe site is about 10 mm.
Too loose probes may interfere with alignment of LEDs and detector, come o� easily by body movement, cause larger motion artifacts or be e� ected by venous pulse.
Too tight probes may cause venous pulsation, cause skin injuries such as burn and necrosis or unstable measurement because of a lower pulsatile signal.
Defi brillators > SpO2 Measurement
Reasons to measure ETCO₂ (the level of carbon dioxide in the air exhaled from the body –
normal value is about 38 mm Hg): Capnography helps to detect life-threatening problems in:
• Airway
• Breathing
• Circulation and
• Metabolism
Capnography is a fast and reliable help to determinate respiratory di� culties, wrong connections of airway
adapters, leaks in the ventilator circuit due to its placement in the respiratory circuit. An early detection by
capnography might help to avoid inadequate oxygen supply of the body.
ETCO2 Measurement (Capnography)
www.nihonkohden.net69 www.nihonkohden.net69 Defi brillators > ETCO2 Measurement
ETCO2 Measurement (Capnography)The necessity of monitoring ETCO2 is recognized by various health care associations guidelines:
Canadian Anesthesia Society (CAS)Guidelines for Sedation – January, 2012
Anesthesia Patient Safety Foundation (APSF)Monitoring with Use of Post-op Opioids – August, 2011
American Society for Anesthesiologists (ASA)Standards for Basic Anesthetic Monitoring – July, 2011
Association of Anaesthetists of Great Britain & Ireland (AAGBI) The use of capnography outside the operating theatre – May, 2011
American Association of Respiratory Care (AARC) CPG for Capnography/Capnometry During Mechanical Ventilation – April, 2011
British Royal College of AnesthetistsAirway Recommendation (NAP4) – March, 2011
European Resuscitation Council (ERC)Guidelines for Resuscitation – November, 2010
American Heart Association (AHA)Resuscitation Guideline – November, 2010
Suck in
Sampling tube
Sidestream Method
In a sidestream system, a gas
sample is removed from the
patient’s airway and delivered
to a distant sensor.
Measurement values delayed.
Not possible with
NIHON KOHDEN defi brillators.
Capnometer
CO2 Sensor
CO2 Sensor
Mainstream Method
In a mainstream system, the
sensor is located directly in
the patient’s breathing circuit.
Real time measurement values.
Capnometer
Is CO2 the only gas to measure?
Is the patient a neonate?
Is the patient intubated?
Mainstream measurement
Yes
Yes
Yes
Yes
No
No
Multi-gas measurement
Please use NIHON KOHDENpatient monitors!
CO2 sensor kit P907 (TG-920P) & P908 (TG-921T3)
Both intubated & non-intubated
Emergency
Is a humidifi er or nebulizer used?
CO2 sensor kit P909 (TG-970P)
R805 (YG-211T) Airway adapter adult (> 7 kg)
CO2 sensor kit P909 (TG-970P)
R805 (YG-211T) Airway adapter adult (> 7 kg)
CO2 sensor kit P903 (TG-900P)R801 (YG-101T) Airway adapter adult, (> 10 kg)
With nebulizer
No
Intubated
R804 (YG-111T) Airway adapter (> 7 kg)
Non-intubated
No
V921 (YG-120T) Nasal adapter (> 10 kg)
V922 (YG-121T) Nasal/Oral adapter (>10 kg)
V923 (YG-122T) Nasal/Oral adapter with O₂ supply tube adapter (> 10 kg)
NKD-02-Cap Oxygen cannula
No measurement possible
No
Start ETCO2 Selection Guide
Normal capnograph and ETCO2 waveform
ETCO2 shows clinical and technical problems
ETCO2 Measurement OverviewThe best way to observe the patient‘s respitatory condition
Normal range: steep rising and fl at expiratory phase Hyperventilation Hypoventilation
mmHg
PaCO2 level
ETCO2
45
35
Hypoventilation Increasing CO Malignant high fever Pain of light anesthesia
Normal range
HyperventilationDecreasing COPulmonary embolismDeep anesthesia
Trend
· Downward · Upward
Disconnection in breathing circuitAsphyxiaVentilator stop
HyperventilationDecreasing COPulmonary embolism Temperature decrease
Partial obstruction ofbreathing circuit
Sudden disappearance of CO2 waveform
HypoventilationTemperature increaseMalignant high fever
40
40
40
40
Breathing circuit abnormality Respiratory abnormality
Sudden decrease of CO2 Gentle expiratory phase
· Breathing circuit abnormality · Obstructive defect, bronchial spasm ETCO2=PaCO2
40 40
Sudden decrease of CO2 toward zero Gentle expiratory phase
· Ventilation disconnection · Rebreathing
40 40
Zero CO2 or very low CO2 Cumulative irregular respiratory waveform
· Esophageal intubation · Spontaneous breathing
40 40
CO2monitor
Bloodcirculation
BreathingAirway
MetabolismPulmonary circulation
Gas exchange
Connector Ventilator
Respiratory Circuit
Fresh gasCO2 absorber
Conditions refl ected by ETCO25 phases of the capnograph
Beginning ofexhalation
Start exhalationof CO2 in alveoliof the lung
Plateau of CO2 in alveoli of the lung
Inhalation phase
End of exhalation
ETCO2 and PaCO2 show ventilation and pulmonary blood fl ow condition
46 mmHg 46 mmHg
40 mmHg ( PaCO2)
40 mmHg ( ETCO2)
40 40 404640
40
43 mmHg ( PaCO2)
20 mmHg ( ETCO2)
40 mmHg ( PaCO2)
Normal ventilation Abnormal ventilation and normal pulmonary blood fl ow
Normal ventilation and abnormal pulmonary
blood fl ow
46 mmHg 46 mmHg 46 mmHg 46 mmHg
40 mmHg ( ETCO2)
Early detection of trouble in breathing or ventilation equipment
Inadequateventilation Kink Disconnection
Apnea Obstruction
Esophageal intubation
Leak
Malfunction
Indequategas fl ow
CO2 Measurement is useful in many hospital sites
ER ICU SedationPSG
Nihon Kohden Unique Sensing Technology
40 40 040
ETCO2 Mainstream
Application Fields of Airway Adapters for Intubated Patients
Application Fields of Nasal Adapters for Non-Intubated Patients
Emergency / Pre-hospital Care
• Detection of endotracheal tube displacement• Control of CPR effi cacy• ROSC detection (Return of Spontaneous Circulation)• Oxygenation management• Airway circuit management • Keeping ICP appropriate by checking ETCO2 level (i.e. patients with craniocerebral injury – CCI) • Detection of respiratory distress (occlusion, connection leak, accidental extubation, ventilator trouble etc.)• Detection of poor pulmonary perfusion• Apnea monitor• Detection of eff ectiveness of treatment
Transport / Pre-hospital Care
• Detection of changes in respiratory status (over- or underventilation of trauma / shock victims; COPD patients)• Detection of respiratory depression of sedated patients or anaesthesia without intubation• Spot-checking of ETCO2 level & respiration rate of critically ill non-intubated patients• Detection of eff ectiveness of treatment
www.nihonkohden.net72
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Intubated Expired ETCO2
Supply CodeP906
ModelTG-901T3
DescriptionCO2 Sensor Kit for Intubated Patients, semi-quantitative measurement, incl. CO2 sensor and CO2 adapter, expiratory CO2, cable length: 3.0 m For Airway Adapters: R801For current products: TEC-5500/7700Packing unit: 1 pcs
P903 TG-900P CO2 Sensor Kit for Intubated Patients, semi-quantitative measurement, incl. P922A/K981, expiratory CO2, cable length: 3.0 m For Airway Adapters: R801For current products: all BSM/PVM-2703/OLG-2800/TEC-8300Packing unit: 1 pcs
P922A TG-101T CO2 Sensor for Expiratory CO2 for Intubated Patients, part of CO2 Sensor Kit P903, cable length: 1.0 m, requires Adapter Cable: K981For current products: all BSM/PVM-2703/OLG-2800/TEC-8300Packing unit: 1 pcs
K981 JG-900P CO2 Adapter Cable for P922A/P903, cable length: 2.0 mFor current products: all BSM/PVM-2703/OLG-2800/TEC-8300Packing unit: 1 pcs
R801 YG-101T Airway Adapter for P903/P906/P922A, intubated, semi-quantitative method, child/adult (>10 kg), dead space: 5 mlFor current products: all BSM/PVM-2703/OLG-2800/TEC-8300Packing unit: 50 pcs
Defi brillators > ETCO2 Measurement
www.nihonkohden.net73
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Intubated Expired and Inspired ETCO2 “Opening a New Era in Capnography“
Facts
NIHON KOHDEN CO2 Sensor Sensation - P909 World‘s smallest and lightest mainstream ETCO2 sensor (quantitative method) with only 4 g (±2 g). This avoids tube pressures and increases patient comfort. Especially for this reason as well as the dead space of approximately 1 ml it is perfectly suited to the most sensible intubated patients – neonates in critical care (application on neonates only with patient monitors). Besides this P909 can be also applied to children and adults. Easy and simple handling is guaranteed by its waterproofness (IPX7 standard) and our Smart CableTM Technology so that no additional module is needed. Just plug in and start a continuous measurement after only 10 seconds warm-up time. Those features make the P909 an unbeatable help for daily work routine in OR, ER, ICU or Ward.
Supply CodeP909
ModelTG-970P
Descriptioncap-ONE CO2 Sensor Kit for Intubated Patients, quantitative measurement, incl. P924/K987, size: 8 x 13 x 35 mm, cable length: 3.5 mFor Airway Adapters: R805For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100Packing unit: 1 pcs
P924 TG-221T cap-ONE CO2 Sensor for Intubated Patiens, part of CO2 Sensor Kit P909, cable length: 3.0 mFor current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100Packing unit: 1 pcs
K987 JG-970P cap-ONE CO2 Adapter Cable for P909/P924, cable length: 0.5 mFor current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100Packing unit: 1 pcs
R805 YG-211T Airway Adapter for P909, intubated, quantitative method, adult (> 7 kg), dead space: 4 mLFor current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100Packing unit: 30 pcs
Defi brillators > ETCO2 Measurement (Capnography)
www.nihonkohden.net74
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Intubated and Non-Intubated Expired ETCO2 “Opening a New Era in Capnography“FactsNIHON KOHDEN cap-ONE–when every breath counts!World’s fi rst wearable mainstream ETCO2 sensor P907 (semi-quantitative method) for intubated and non-intubated patients which is applicable for children and adults.Unique oral-nasal airway adapters catch oral as well as nasal expired CO2 – this increases accuracy. The cap-ONE is not only small but has also a mini-weight of only 4 g. This avoids tube pressures and increases patient comfort. Easy and simple handling is guaranteed by our Smart CableTM Technology so that no additional module is needed, just plug in and start measuring after only 5 seconds. A continuous, stable and accurate measurement is ensured due to no lag time and no need to change tubes because of occlusions. Its waterproofness and outstanding shock resistance are an unbeatable advan-tage in daily work routine. Those features make the cap-ONE P907 an excellent measurement tool in OR, ICU, Recovery Room, PACU, Transport, ER, Cardiac Catheter Laboratory, GI Endoscopy, Pain Management, Abdominal Operation, Obstetric/Orthopedic/Eye Surgery, Plastic or Dental Surgery.
Supply CodeP908
ModelTG-921T3
Descriptioncap-ONE CO2 Sensor Kit for Intubated/Non-Intubated Patients, semi-quantitative measurement, incl. CO2 sensor and CO2 Adapter, size: 11 x 11 x 40 mm, cable length: 3.5 mFor Airway Adapters: Intubated patients: R804Non-Intubated patients: V921/V922/V923For current products: all EEG/TEC-5500/7700; EEG-1200/9100/9200 with JE-921A/921AGPacking unit: 1 pcs
P907 TG-920P cap-ONE CO2 Sensor Kit for Intubated/Non-Intubated Patients, semi-quantitative measurement, incl.P923/K984, size: 11 x 11 x 40 mm, cable length: 3.5 mFor Airway Adapters: Intubated patients: R804Non-Intubated patients: V921/V922/V923For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100Packing unit: 1 pcs
P923 TG-121T cap-ONE CO2 Sensor for Intubated/Non-Intubated Patients, part of CO2 Sensor Kit P907/P908, cable length: 1.5 mRequires Adapter Cable: K984For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100Packing unit: 1 pcs
K984 JG-920P cap-ONE CO2 Adapter Cable for P923/P907, cable length: 2.0 mFor current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100Packing unit: 1 pcs
Defi brillators > ETCO2 Measurement (Capnography)
www.nihonkohden.net75
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Supply CodeR804
ModelYG-111T
DescriptionAirway Adapter for P907/P908/P923, intubated, child/adult (> 7 kg), dead space: 4 mLFor current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100Packing unit: 30 pcs
V921 YG-120T CO2 Nasal Adapter for Nasal Breathing, non-intubated, child/adult (> 10kg)For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/EEG/PSG-1100Packing unit: 30 pcs
V922 YG-121T CO2 Nasal Adapter for Nasal/Oral Breathing, non-intubated, child/adult (> 10 kg)For current products:all BSM/PVM-2703/OLG-2800/TEC-8300/EEG/PSG-1100Packing unit: 30 pcs
V923 YG-122T CO2 Nasal Adapter for Nasal/Oral Breathing with Oxygen Cannula Holder,non-intubated, child/adult (> 10kg)For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/EEG/PSG-1100Packing unit: 30 pcs
NKD-O2-CAP Oxygen Cannula for Nasal Adapter V923 for P907/P908For current products: all BSM/PMV-2703/OLG-2800/TEC-8300/EEGPacking unit: 50 pcs
NKD-CO2GAS Calibration Gas for CO2 Measurement Please store the gas below 50°C!For current products: all BSM/TEC-8300Packing unit: 1 pcs
NKD-VENTIL3 CO2 Gas ValveFor current products: all BSM/TEC-8300Packing unit: 1 pcs
Defi brillators > ETCO2 Measurement (Capnography)
Temperature Measurement
StandardTemperature
Measurement of 2 Additional Temperatures
www.nihonkohden.net77
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Defi brillators > Temperature Measurement
Standard Temperature Measurement
Supply CodeNKD-P240A
ModelYSI-401
DescriptionOesophagus/Rectum Thermistor Probe, adult, 6.3 mm jack connector, size: 4 mm dia, length: 3.5 mFor current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs
NKD-P241A YSI-402 Oesophagus/Rectum Thermistor Probe, neonate/child, 6.3 mm jack connector, size: 3.3 mm dia, length: 3.5 mFor current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs
NKD-P242B YSI-409B Body Surface Temperature Probe, 6.3 mm jack connector, disk size: 9.5 mm dia, cable length: 3.5 mFor current products: all BSM/PVM-2703/TEC-8300/MEB-9200/MEB-2300Packing unit: 1 pcs
NKD-P249 ZM: S616 Temperature Probe Cover for NKD-P240A/241AFor current products: all BSM/PVM-2703/TEC-8300Packing unit: 10 pcs
Tempheart Adhesive Pads, to fi x temperature probes, size: 1.5 cm diaFor current products: all BSM/PVM-2703/TEC-8300/MEB-9200/MEB-2300Packing unit: 100 pcs
Mini-Tempheart Adhesive Pads, to fi x temperature probes, size: 1.13 cm diaFor current products: all BSM/PVM-2703/TEC-8300/MEB-9200/MEB-2300Packing unit: 100 pcs
Measurement of 2 Additional Temperatures
Supply CodeK961
ModelJT-900P
DescriptionTemperature Connection Cable for NKD-P241/242x, cable length: 0.3 mFor current products: BSM-5100/6000/9100/ TEC-8300Packing unit: 1 pcs
NKD-TEMPHEARTS4009
NKD-TEMPHEARTS4012
NIBP Air Hoses
Disposable NIBP Cu� s
Reusable NIBP Cu� s – NEW YAWARA CUFF 2
Blood pressure (BP) is the pressure exerted by circulating blood against the artery walls. During each heartbeat, the blood
pressure varies between a maximum (systolic) and a minimum (diastolic) pressure. The variation indicates the condition
of the pumping function of the heart as an important vital sign.
A non-invasive indirect method to measure the blood pressure is the oscillometric blood pressure measurement. This me-
thod is using an infl ated blood pressure cu� which is applied to the patient’s arm or thigh. The blood pressure is detected
by partial occlusion of the artery by the cu� . The so called Korotko� sound is generated by the distension of the arterial
wall with each cardiac impulse. Systolic and diastolic blood pressures are determined by an algorithmic interpretation of
the device based on the mean arterial pressure and changing amplitude of the Korotko� sounds.
For a proper non-invasive measurement it is important to use the correct cu� size due to the fact that a cu� too small will
lead to faulty high pressure, while a large cu� can lead to wrong low pressure readings.
NIBP Measurement (Non-Invasive Blood Pressure)
www.nihonkohden.net79
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Defi brillators > NIBP Measurement (Non-invasive Blood Pressure)
NIBP Air Hoses
Supply CodeS901
ModelYN-900P
DescriptionChild/Adult NIBP Air Hose, cable length: 1.5 mFor current products: all BSM/PVM/TEC-7700/8300Packing unit: 1 pcs
S902 YN-901P Child/Adult NIBP Air Hose, cable length: 3.5 mFor current products: all BSM/PVM/TEC-7700/8300Packing unit: 1 pcs
S903 YN-990P NIBP Air Hose Extension Cable, cable length: 1.5 mFor current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 1 pcs
www.nihonkohden.net80
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Defi brillators > NIBP Measurement (Non-invasive Blood Pressure)
Reusable NIBP Cu� s – NEW YAWARA CUFF 2
Facts The trade name YAWARA CUFF comes from the Japanese word, YAWARAKAI, whichmeans soft in touch.YAWARA CUFF 2 is available in 6 sizes. The exterior size-scale quickly helps inselecting the proper cu� size, from infant to large adult or thigh.The velcro part of the cu� is divided into two high quality velcro types. This helpsto fi x the cu� on the arm with the fi rst velcro part whereas you can completelyadjust the cu� with the second velcro part.YAWARA CUFF 2 uses a soft and smooth cloth together with a bu� er sheet to reduce the risk of subcutaneous bleeding. The fabric is hypoallergic and allows the skin to breathe. Furthermore, the material of the cloth can be easily wiped clean.A wider opening of the cu� cover allows very easy removal of the bladder forcleaning.The watertight connector cap keeps out liquid during cleaning the bladder. Thereis a nylon fi bre inside the air tube for kink-free tube. There is a nylon fi bre inside the air tube preventing kinking and incidents associated with tube kinking. YAWARA CUFF 2, a new generation of NIBP cu� s.
Kink-free tubeEasy to clean with watertight connection cap
Indicator of appropriate range of attachment site
Easy handling of an infl ation bagWith a wide slit, it is easy to remove and replace the infl ation bladder.
YAWARA CUFF 2 has a kink-free tube. The tube will not kinked - even if bent through a 180-degree angle.
YAWARA CUFF 2 has a watertight connector cap, which prevents fl uid from entering the tube (and bladder) during cleaning.
With a clear indication of PROPER SIZE printed on the cu� , you can see at a glance if the cu� size is correct for your patient.
Reducing internal bleedingIf wrinkles are formed as below, part of the measuring site may be trapped in the valley portions of the wrinkles, which could cause internal bleeding. YAWARA CUFF 2 has a cushion between an infl ation bag and skin to avoid these wrinkles and reduces internal bleeding.
cushion
wrinklesinfl ation bag
• Soft and gentalon the skin• Highly accurate• Easy to use
www.nihonkohden.net81
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Defi brillators > NIBP Measurement (Non-invasive Blood Pressure)
Supply CodeS951A
ModelYP-710T
DescriptionInfant NIBP YAWARA CUFF 2, width: 5 cm, arm-circumference: 8 to 13 cm, latex-freeFor current products: BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 1 pcs
S951B YP-711T Child NIBP YAWARA CUFF 2, width: 7 cm, arm-circumference: 13 to 19 cm, latex-freeFor current products: BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 1 pcs
S951C YP-712T Adult Small NIBP YAWARA CUFF 2, width: 10 cm, arm-circumference: 19 to 23 cm, latex-freeFor current products: BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 1 pcs
S951D YP-713T Adult NIBP YAWARA CUFF 2, width: 13 cm, arm-circumference: 23 to 33 cm, latex-freeFor current products: BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 1 pcs
S951E YP-714T Adult Large NIBP YAWARA CUFF 2, width: 16 cm, arm-circumference: 33 to 45 cm, latex-freeFor current products: BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 1 pcs
S951F YP-715T Adult Thigh NIBP YAWARA CUFF 2, width: 19 cm, thigh-circumference: 45 to 55 cm, latex-freeFor current products: BSM/PVM/TEC-77/8300; ZS/ZM-940PGPacking unit: 1 pcs
www.nihonkohden.net82
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Defi brillators > NIBP Measurement (Non-invasive Blood Pressure)
Disposable NIBP Cu� sDisposable NIBP Cu� s for Infants & Children
Supply CodeNKD-NIBP/K2
Description Disposable NIBP Cu� Trial Kit for ChildrenSet contains:3 cu� s of NKD-S947A4 cu� s of NKD-S947B3 cu� s of NKD-S947CFor current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 1 set
NKD-S947A Infant NIBP Cu� , width: 6 cm, arm-circumference: 8 to 14 cm, color: blue, latex-freeFor current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 20 pcs
NKD-S947B Child NIBP Cu� , width: 8 cm, arm-circumference: 13 to 20 cm, color: green, latex-freeFor current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 20 pcs
NKD-S947C Small Adult NIBP Cu� , width: 10 cm, arm-circumference: 18 to 26 cm, color: orange, latex-freeFor current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 20 pcs D
www.nihonkohden.net83
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Defi brillators > NIBP Measurement (Non-invasive Blood Pressure)
Disposable NIBP Cu� s for Adults
Supply CodeNKD-NIBP/K3
Description Disposable NIBP Cu� Trial Kit for AdultsSet contains:1 cu� of NKD-S947C4 cu� s of NKD-S947D3 cu� s of NKD-S947F2 cu� s of NKD-S947HFor current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 1 set
NKD-S947C Small Adult NIBP Cu� , width: 10 cm, arm-circumference: 18 to 26 cm, color: orange, latex-freeFor current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 20 pcs
NKD-S947D Adult NIBP Cu� , width: 14 cm, arm-circumference: 26 to 35 cm, color: blue, latex-freeFor current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 20 pcs
NKD-S947E Adult Long NIBP Cu� , width: 15 cm, arm-circumference: 29 to 38 cm, color: red, latex-freeFor current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 20 pcs
NKD-S947F Large Adult NIBP Cu� , width: 17 cm, arm-circumference: 32 to 42 cm, color: green, latex-free, disposableFor current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 20 pcs
NKD-S947G Large Adult Long NIBP Cu� , width: 18 cm, arm-circumference: 35 to 44 cm, color: orange, latex-freeFor current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 20 pcs
NKD-S947H Adult Thigh NIBP Cu� , width: 20 cm, arm-circumference: 42 to 50 cm, color: blue, latex-freeFor current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 20 pcs
Blood pressure (BP) is the pressure exerted by circulating blood against the artery walls. During each heartbeat, the
blood pressure varies between a maximum (systolic) and a minimum (diastolic) pressure. The variation indicates the
condition of the pumping function of the heart as an important vital sign.
A direct method to measure the blood pressure is the invasive blood measurement using catheters inserted into the
blood vessels, fi lled with saline solution and measure the pressure electrically with a connected transducer.
IBP Measurement (Invasive Blood Pressure)
Transducer Cable with Direct Connection
IBP Transducer Cable with Adapter Cable K952
www.nihonkohden.net85
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Defi brillators > IBP Measurement (Invasive Blood Pressure)
IBP Transducer Cable with Direct Connection
Supply CodeK951
ModelJP-900P
DescriptionIBP Connection Cable for Becton Dickinson Transducers, cable length: 3.5 mFor current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs
K952 JP-910P For current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs
K957 JP-960P For current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs
L901 JP-920P For current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs
L902 JP-921P For current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs
www.nihonkohden.net86
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Defi brillators > IBP Measurement (Invasive Blood Pressure)
IBP Transducer Cable with Adapter Cable K952
Supply CodeNKD-5203201
DescriptionIBP Connection Cable for B. Braun Transducers, cable length: 3.0 m, requires K952For current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs
NKD-BDP178NK1 IBP Connection Cable Set for Codan Transducers, incl. adapter cable with1 Pressure Connection, contact board Xtrans BDC901 and holding plate B180090, cable length: 0.5 m, requires K952Applicable for Codan Transducers: Series xTrans: DPT-9003, DPT-9009, DPT-9300, DPT-9990For current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 set
NKD-BDP178NK4 IBP Connection Cable for Codan Transducers with 4 Pressure Connections, cable length: 0.5 m, requires K952Applicable for Codan Transducers: Series xTrans: DPT-9003, DPT-9009, DPT-9300, DPT-9990For current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs
NKD-BDPT-1078 IBP Connection Cable for Codan Transducers with 1 Pressure Connection, cable length: 3.5 m, requires K952Applicable for Codan Transducers: Series xTrans: DPT-6000For current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs
NKD-IBP/LOGICAL IBP Connection Cable for Medex Transducers with 1 Pressure Connection, cable length: 4.0 m, requires K952Applicable for Medex Transducers: Series LogicalFor current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs
NKD-IBP/LOGICAL2 IBP Connection Cable for Medex Transducers with 2 Pressure Connections, cable length: 4.0 m, requires K952Applicable for Medex Transducers: Series LogicalFor current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs
www.nihonkohden.net87
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Defi brillators > IBP Measurement (Invasive Blood Pressure)
Supply CodeNKD-IBP/LOGICAL3
DescriptionFor current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs
NKD-IBP/LOGICAL4 For current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs
NKD-IBP/NOVATRANS For current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs
NKD-IBP/TRANSPAC IBP Connection Cable for TRANSPAC Transducers with 1 Pressure Connection, cable length: ca. 4.5 m, requires K952Applicable for Abbott Transducers: Transpac IT, Transpac IVFor current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs
NKD-IBP/TRANSTAR For current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs
NKD-IBP/UTAH plusFor current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs
NKD-IBP/UTAH2 For current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs
www.nihonkohden.net88
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Enhancement of patient status due to optimized quality and effectiveness of chest compression (detectable with ETCO2 value)
For inexperienced users, for fi rst aid trainings, in hospitals, airports and aircrafts/trains and/or for rescue operations.
• Applicable to adults and children from 8 years!
• 10 hours non-stop operation (acoustic warning) or up to 5 years stand-by time!
• Available in 17 different languages!
(stock: German, English, Italian, French, Spanish; on request: Danish, Finnish, Dutch, Hungarian, Czech, Norwegian, Polish, Portuguese, Russian, Swedish, Hebrew, Croatian)
Portable CPR – For use by anyone! Reusable, portable and smart – a simple and fast emergency aid tool for chest compression!
Ideal tool for professionals and inexperienced users due to continuous real time feedback during chest compression
NKD-CPR
Perfecting of chest compression effectiveness (ideal compression depth 4 - 5 cm, 100 compressions/minute) complies with current ERC Guidelines
Continuous acoustic and visual real time feedback for compression frequence and depth during chest compression (metronome/verbal directions/light-emitting diodes)
Only a few steps may help save a life:
• Stay calm!
• Check the responsiveness/consciousness of the person with cardiac arrest (victim)!
• Call to an emergency doctor! / Call for help!
• If available, use an AED (defi brillator for inexperienced users with verbal directions / visual aid) and a Pocket CPR!
• Check the breathing of the concerned person (victim) and free the airway if necessary!
• Start chest compression (30 x) and perform rescue breathing to the victim (2 x)!
• Continue with chest compressions and rescue breaths in a ratio of 30:2 (30 chest compressions, 2 rescue breaths) until the appearance of the emergency doctor!
Defi brillators > Portable CPR
www.nihonkohden.net89
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Defi brillators > Portable CPR
Portable CPR
Supply CodeNKD-CPR
DescriptionPortable CPR Please indicate your language when ordering! Available languages on stock : German, English, French, Italian, SpanishAvailable languages on request: Danish, Finnish, Dutch, Hungarian, Czech, Norwegian, Polish, Russian, Swedish, Hebrew, CroatianPacking unit: 1 pcs
NKD-SIPADS Disposable Silicone Pads for Portable CPR, 3 mm self-adhesive silicone pads for optimal placement of the Portable CPR on patient�s chestPacking unit: 5 pcs
NKD-STPADS Disposable Sticky Pads for Portable CPR, thin self-adhesive pads for optimal placement of the Portable CPR on patient�s chestPacking unit: 50 pcs
NKD-CPR/COVER Silicone Cover for Portable CPRPacking unit: 1 pcs
Additional Defi brillator Accessories
www.nihonkohden.net91
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Defi brillators > Additional Defi brillator Accessories
Additional Defi brillator Accessories
Supply CodeF015
ModelZ-101EA
Description“Gelaid” Defi brillator Contact Gel, 100 g tubeFor current products: all TECPacking unit: 5 pcs
NKD-JJ221V R2 Adapter Cable for Laerdal/Ambu Training Doll, requires R2Adapter cable JC-755V/K342AFor current products: TEC-5500/7700/8300Packing unit: 1 pcs
NKD-L936 Power Cable, Schuko plug, cable length: 2.0 mPacking unit: 1 pcs
NKD-POWERLINE Multiple Power Socket (4 slots), medical certifi cationFor current products: all TECPacking unit: 1 pcs
NKD-SD1GB Memory SD Card 1 GBPacking unit: 1 pcs
Y011 404617 Thermal Head Cleaner PenFor current products: all ECG/TEC/old MEB/EEG/all BSM/PVM/OPV/WEPPacking unit: 1 pcs
Acc essories for AED & Training Unit
Don�t let premature death claim the lives around youSudden Cardiac Arrest (SCA) is among the leading causes of death in the world. In SCA, the heart suddenly and unexpectedly stops functioning. When this happens, the heart is no longer able to pump blood to the rest of the body. This usually results in death if not treated within minutes.
Heavy chest pains, nausea and weakness are common symptoms of SCA. More often than not, the victim also feels an impending sense of doom refl ecting their predicament.
SCA can strike anytime and any place, and can happen to anyone.
Don�t let SCA claim lives prematurely when something can be done about it.
ACT NOW!Give every life a chance to live.
www.nihonkohden.net94
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
A strong Chain of Survival improves chance of survival
The “Chain of Survival” is a proven approach to the early treatment of sudden cardiac arrest, heart attack, stroke and any other emergency. It consists of four crucial links:
EARLY ACCESSto get help
EARLY CPRto buy time
EARLY ACLSto stabilize
EARLY DEFIBRILLATIONto restart heart
1. Early Access - to activate the Emergency Medical Services (EMS).
2. Early Cardiopulmonary Resuscitation (CPR) – to slow the rate of deterioration
of the brain and heart, and buy time to enable defi brillation.
3. Early Defi brillation – to restore to a normal heart rhythm.
4. Early Advanced Cardiac Life Support (ACLS) – to stabilise the patient.
Any delay in any of these links could potentially be fatal or decrease the chance of survival.
Most people who die of heart attacks experience irregular heartbeats known as ventricular fi brillation (VF); a condition where the heart stops circulation of blood. lf left untreated, the victim will die within minutes. By far, defi brillation (electric shock) is the only known treat-ment to revert a troubled heart from VF to its normal rhythm.
Defi brillators > Accessories for AED & Training Unit
www.nihonkohden.net95
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Importance of AED in the Chain of Survival
Automated External Defi brillator or AED is perhaps the most important link in the chain to improve the SCA victim‘s survival chances.
An AED is a device that is used to diagnose and treat potentially life thre-atening abnormal heart rhythms by providing the means to apply con-trolled electrical shocks (known as defi brillation shocks) to the heart in an attempt to stop these abnormal rhythms, thereby allowing the heart to establish again an e� ective rhythm.
It will also provide guidance by simple and clear vocal instructions to the rescuer during the rescue sequence.
Studies have shown that the time to fi rst defi brillation shock is the most crucial factor in determining survival rates for SCA*. When an AED is available, it should always be applied to the SCA victim at the earliest.
Survival rate (after 1 month)
Rehabilitation rate (after 1 month)
50,0%
0,5%
10,0%
15,0%
20,0%
25,0%
30,0%
35,0%
40,0%
45,0%
0
9,8%
43,8%
38,2%
5,6% Non use AEDUse AED
For over 90% of SCA cases, death usually occurs if without intervention. However, as many as 30-50% would likely survive if AED and CPR was administered within fi rst 5 minutes of collapse. Survival chance can be signifi cantly increased with early defi brillation.
* Report of Japan FDMA (Fire and Disaster Management Agency/2008)
For every minute of delay in giving CPR and defi brillation following collapse, the survival rate decreases by 7–10%. So, why let tragedies happen where there is prevention available now? The result of not having an AED may well be another fatal case.
Defi brillators > Accessories for AED & Training Unit
www.nihonkohden.net96
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or
between di� erent applications to prevent or reduce the risk of cross infections!
Defi brillators > Accessories for AED & Training Unit
Accessories for AED Units
Supply CodeH324A
ModelP-530K
DescriptionDefi brillation Pads, child/adult, for use with adapter cable JC-765V/K342B, weight: 85 g ± 15 g), size: 109 mm x 15 mm (± 10 mm),conductive surface: 86.68 cm2 (±10%), cable length: 1.5 mFor current products: AED-21xxPacking unit: 1 pair
SB-210VK X212A 2-Years Standby Battery for all devices until SN: 5000For current products: AED-21xxPacking unit: 1 pcs
SB-212VK X216A 2-Years Standby Battery for all devices starting from SN: 5001For current products: AED-21xxPacking unit: 1 pcs
SB-214VK X217A 4-Years Standby Battery for all devices starting from SN: 5001For current products: AED-21xxPacking unit: 1 pcs
Y184A YC-210V AED Carrying Bag. AED usage is possible without taking out from the bag!For current products: AED-21xxPacking unit: 1 pcs
Accessories for AED Training Unit TRN-2100K
Supply CodeH326
DescriptionTraining Pads, child/adultFor current products: TRN-2100KPacking unit: 1 pair
Y262B Replacement Stickers for TRN-2100K Training PadsFor current products: TRN-2100KPacking unit: 10 pcs
ACCESSORY ORDER FORMFor your convenience we have a printable order form so that you can fax in your order directly or mail/e-mail it to us. Please make sure to fi ll out all the information requested below!
Hospital/Practice
Contact Person Department
Customer Code Address
ZIP City
Phone Fax
ACCESSORY ORDER FORM
Standard 3 Days 2 Days Overnight
Monthly, please contact me for more details Other
Supply Code Description Required Quantity Price each in EUR / £ Price Total in EUR / £
Send in your order today! For Germany, Austria, Switzerland and BeneluxFax: +49 (0) 33203/573-19, E-Mail: bestellung@nke.de For Spain and Portugal Fax: +34 91 300 46 76, E-Mail: info@nkib.es For United KingdomFax: +44 (0) 20 83 90 46 75, E-Mail: mail@nihonkohden.co.uk
For France Fax: +33 (0) 1 49 08 93 32, E-Mail: info@nkfrance.frFor Italy Fax: +39 (0) 35-232546, E-Mail: info@nkitaly.com For all other European Countries, Russia, Turkey and Israel Fax: +49 (0) 6003/827-599, E-Mail: info@nke.de
www.nihonkohden.net
www.nihonkohden.net98 www.nihonkohden.net98
6124-039432 47
A052 25
A053 25
A128 25, 34
A129 25
A222 34
A226 34
A238 34
F010 28
F015 91
G203 20, 54
G204 20, 54
G207 20, 54
G210C 21, 55
G210D 20 ,54
G236 20
G250 20, 54
G271A 55
G272A 54
G272B 54
G272C 55
G278A 55
H041A 18
H043A 18
H044A 18
H044B 18
H049 18
H052A 18
H052B 18
H068A 17
H068B 17
H072 17
H312 38
H324A 96
H326 96
H327 38
JC-755V 39
JC-765V 38
K079 13
K081 13
K082 13
K093C 13
K093D 13
K093F 13
K093L 14
K096A 13
K096B 13
K097 15
K098 15
K117A 29
K117B 29
K117C 29
K118 14
K119 14
K120 47, 50
K225 50
K226 50
K227 51
K228 51
K232 52
K234 52
K332 52
K336 50, 51
K342A 39
K342B 38
K350A 52
K351A 52
K352A 50
K352B 51
K353A 50
K353B 51
K354 48
K901 48
K910A 47, 50
K910A 47, 50
K911 47, 50
K912 47
K913A 47
K915 48
K922 48
K931 58
K951 85
K952 85
K957 85
K961 77
K981 72
K984 74
K987 73
KB01A 14
KB02A 14
KB03A 14
KB04A 14
KB05A 14
KB06A 14
KB07A 14
KB08A 14
KB09A 14
KB010 14
KB012 14
KB10C 14
KB11C 14
KB12D 14
KB13B 14
KB13D 14
KB14B 14
KB15B 14
KB16B 14
KB17B 14
KB18B 14
KB19C 14
L151 52
L152 52
L153 52
L901 85
L902 85
N-00 21
N-08 21
ND-593V 42
ND-594V 42
ND-595V 42
ND-596V 42
ND-597V 42
ND-612V 42
ND-893V 41
ND-894V 41
ND-895V 41
ND-896V 41
ND-897V 41
NKD-145-2,5 26
NKD-145-6A300 26
NKD-210-10/295 25
NKD-210-5-295 25
NKD-5203201 86
NKD-63 26
NKD-A054 25
NKD-A129 26
NKD-A134A 26
NKD-A226 34
NKD-A730 25
NKD-BAG 28
NKD-BDP178NK1 86
NKD-BDP178NK4 86
NKD-BDPT-1078 86
NKD-CO2GAS 75
Index as per Supply Code
Index as per Supply Code
Supply Code page Supply Code page Supply Code page Supply Code page
www.nihonkohden.net99 www.nihonkohden.net99
NKD-CPR 89
NKD-CPR/COVER 89
NKD-DEFIBAG2 36
NKD-DEFIBAG3 36
NKD-DEFIBAG6 36
NKD-DEFIBAG83 36
NKD-ECG/TAB1 19
NKD-ECG/TAB2 19
NKD-G711 28
NKD-H/ADAPTER2 19
NKD-H405 39
NKD-H406 39
NKD-IBP/LOGICAL 86
NKD-IBP/LOGICAL2 86
NKD-IBP/LOGICAL3 87
NKD-IBP/LOGICAL4 87
NKD-IBP/NOVATRANS 87
NKD-IBP/TRANSPAC 87
NKD-IBP/TRANSTAR 87
NKD-IBP/UTAH 87
NKD-IBP/UTAH2 87
NKD-JJ221V 91
NKD-L936 28, 91
NKD-NIBP/K2 82
NKD-NIBP/K3 83
NKD-O2-CAP 75
NKD-P240A 77
NKD-P241A 77
NKD-P242B 77
NKD-P249 77
NKD-POWERLINE 28, 91
NKD-S947A 82
NKD-S947B 82
NKD-S947C 82, 83
NKD-S947D 83
NKD-S947E 83
NKD-S947F 83
NKD-S947G 83
NKD-S947H 83
NKD-SD1GB 28, 91
NKD-SIPADS 89
NKD-STPADS 89
NKD-STRAP83 36
NKD-TEMPHEARTS4009 77
NKD-TEMPHEARTS4012 77
NKD-VENTIL3 75
NKD-Z715 19
NKD-Z722 19
NKD-Z723 19
P203A 63
P203B 63
P203C 63
P203D 63
P203E 64
P203F 64
P203G 64
P203H 64
P204A 64
P204B 64
P204C 65
P204D 65
P204E 66
P204F 66
P204G 66
P204H 66
P225F 61
P225G 61
P225H 61
P228A 65
P228B 67
P229A 65
P229B 67
P259 65, 67
P263 62
P267 62
P310C 62
P311C 62
P903 72
P906 72
P907 74
P908 74
P909 73
P922A 72
P923 74
P924 73
R801 72
R804 75
R805 73
S901 79
S902 79
S903 79
S951A 81
S951B 81
S951C 81
S951D 81
S951E 81
S951F 81
SB-210VK 96
SB-212VK 96
SB-214VK 96
SB-551V 32
SB-801V 32
SC-831V 32
V921 75
V922 75
V923 75
X040 23
X041 32
X041A 23
X041B 23, 32
X060A 32
X065 23, 32
X071 23
X073 23
X077 32
X078 23
Y011 28, 91
Y095A 58
Y184A 96
Y206A 38
Y206B 39
Y262B 96
Index as per Supply Code
Index as per Supply Code
Supply Code page Supply Code page Supply Code page Supply Code page
www.nihonkohden.net100 www.nihonkohden.net100 Index as per Model Code
Index as per Model Code
404617 28, 91
490933 13
6144-000427 18
6144-011852 18
669269 13
AX-250V 38
AX-251V 39
BC-753V 52
BC-755V 52
BC-763V 50
BC-763VA 50
BC-765V 51
BC-765VA 51
BJ-831V 48
BJ-900P 48
BJ-901D 13
BJ-902D 13
BJ-903D 13
BJ-904D 15
BM-901D 15
BR-002P 52
BR-004P 52
BR-018P 50
BR-019P 50
BR-020P 51
BR-021P 51
BR-202D 14
BR-903P 47, 50
BR-906P 47
BR-906V 47
BR-912D 13
BR-913D 13
BR-913E 13
BR-913P 47, 50
BR-916P 48
BR-921D 14
C-150 20, 54
F-150M 20, 54
F-150S 21, 55
FQS50-2-100 34
FQS50-3-100 34
FQW210-10-295 25
FQW210-30-295 25
J-150 20, 54
JC-002P 52
JC-005P 50, 51
JC-761V 52
JC-762V 52
JC-763V 52
JC-855V 39
JC-865V 38
JC-906P 48
JG-900P 72
JG-920P 74
JG-970P 73
JL-550T2 58
JL-900P 58
JP-900P 85
JP-910P 85
JP-920P 85
JP-921P 85
JP-960P 85
JT-900P 77
L-150 20, 54
L-150X 20, 54
LC-S2912NK 23, 32
LCS-2012NK 23
LCT-1912ANK 23
LCT-1912NK-1 32
M-150 20
NA-0003 47
NA-0003 50
NC-124D 18
NKB-102V 32
NKB-301V 23, 32
P-511 38
P-513 38
P-530K 96
PS50-2 34
RQS50-3 25, 34
RQS63-3 25
SB-150D 23
SB-201D 23
SB-831V 32
SB-901D 23
TG-101T 72
TG-121T 74
TG-221T 73
TG-900P 72
TG-901T3 72
TG-920P 74
TG-921T3 74
TG-970P 73
TL-051S 65
TL-052S 67
TL-061S 65
TL-062S 67
TL-201T 61
TL-201T1 61
TL-220T 61
TL-271T 63, 64
TL-271T3 64, 66
TL-272T 63, 64
TL-272T3 64, 66
TL-273T 63, 65
TL-273T3 64, 66
TL-274T 63, 65
TL-274T3 64, 66
TL-630T3 62
TL-631T3 62
V-040M4 54
V-06OM6 55
V-09IO3 55
V-09OM3 54
V-120S3 55
X212A 96
X216A 96
X217A 96
YC-210V 96
YG-101T 72
YG-111T 75
YG-120T 75
YG-121T 75
YG-122T 75
YG-211T 73
YN-900P 79
YN-901P 79
YN-990P 79
YP-710T 81
YP-711T 81
YP-712T 81
YP-713T 81
YP-714T 81
YP-715T 81
YS-093P2 62
YSI-401 77
YSI-402 77
YSI-409B 77
Z-101BC 28
Z-101EA 91
ZM: S616 77
Model Code page Model Code page Model Code page Model Code page
For Germany, Austria, Switzerland and BeneluxNIHON KOHDEN EUROPE GmbH, Vertrieb Deutschland Albert-Einstein-Ring 9, 14532 Kleinmachnow, DeutschlandFax: +49 (0) 33203/573-19, E-Mail: bestellung@nke.de For Spain and Portugal NIHON KOHDEN IBERICA S.L. C/Ulises, 75A, 28043 Madrid, SpainFax: +34 91 300 46 76, E-Mail: info@nkib.es For United KingdomNIHON KOHDEN UNITED KINGDOM Ltd. Tolworth Tower – 19th Floor, Ewell Road, Surbiton, Surrey KT6 7EL, United KingdomFax: +44 (0) 20 83 90 46 75, E-Mail: mail@nihonkohden.co.uk
For France NIHON KOHDEN FRANCE SARL 8, rue François Delage, 94230 Cachan, FranceFax: +33 (0) 1 49 08 93 32, E-Mail: info@nkfrance.frFor Italy NIHON KOHDEN ITALIA S.r.l. Via Fratelli Bronzetti, 28, 24124 Bergamo, ItalyFax: +39 (0) 35-232546, E-Mail: info@nkitaly.com For all other European Countries, Russia, Turkey and Israel NIHON KOHDEN EUROPE GmbHRai� eisenstraße 10, 61191 Rosbach v. d. H., GermanyFax: +49 (0) 6003/827-599, E-Mail: info@nke.de
NKE-BRZ-K/A