UP

2

A3.2

2

A3.0

1

A3.2

2

A3.1

1

A3.1

1

A3.0

A

B

RESIDENCE INN

COURTYARD

S "B" S S S S S S S S S S "C"

S "F"

HKS "D"

Q-Q Q-Q Q-Q Q-Q

Q-Q_ACCESS

S "A"

S "A"

S "A"

2 BR

S "A"

STAIR

LOBBYELEV

ELEC

R324

R522

SC5

R523

R500

R528

ELEV 01

ELEV 01

572 568 566 564 562 560 556 554 552 550 548

571

546

563 561 559 555

553

544

542

540

541

539

3'-5"

4'-234"

CORR

1. FEC DENOTES FIRE EXTINGUISHER CABINETS, SEMI-RECESSED. RUN5/8" THICK FIRE RATED TYPE "X" GYPSUM WALL BOARD BEHIND CABINETCONT. TYPICAL - REFER TO DETAIL 1/A8.8 - REFER TO ENLARGED PLANSFOR EXTINGUISHER LOCATIONS WITHIN SPACES. NCFC section 906.12. FF&E PROVIDED BY OWNER. (RECEIVED, STORED, & INSTALLED BYCONTRACTOR).3. H.I. DENOTES GUEST ROOMS EQUIPPED FOR THE HEARING IMPAIRED.(AUDIO, VISUAL, & TELECOMMUNICATORS)4. C.R. DENOTES "TESA" ELECTRONIC CARD READER DOOR HARDWARE.5. F.D. DENOTES FLOOR DRAIN.6. REFER TO SHEETS A9.1, A9.2 & A9.3 FOR DOOR, WINDOW, & FINISHSCHEDULES.7. REFER TO 11 SERIES FOR REFLECTED CEILING PLANS.8. REQUIRED RATED WALLS & SMOKE PARTITIONS TO BE EFFECTIVELY &PERMANENTLY IDENTIFIED W/ SIGNS OR STENCILING. SUCHIDENTIFICATION SHALL BE PROVIDED ABOVE DECORATIVE CEILINGS & INCONCEALED SPACES. SUGGESTED WORDING "FIRE AND SMOKE BARRIER -PROTECT ALL OPENINGS"9. PROVIDE CORNER GUARDS ON ALL OUTSIDE CORNERS IN CORRIDORS &BACK OF HOUSE AREAS ONLY - CORNER GUARDS SHALL EXTEND FROMTOP OF BASE TO BOTTOM OF CEILING - TYP.10. ALL WOOD AGAINST C.M.U. MUST BE PRESSURE TREATED11. ALL DIMENSIONS ARE FACE OF STUD TO FACE OF STUD UNLESSSTATED OTHERWISE.12. ALL DIMENSIONS, ELEVATIONS, AND ANY OTHER CONDITIONS OF ANYEXISTING STRUCTURES OF OTHER FEATURES SHALL BE VERIFIED BY THEGC AND ANY DISCREPANCIES WITH THE CONTRACT DRAWINGS REPORTEDTO THE ARCHITECT AND ENGINEER BEFORE PROCEEDING WITH THEAFFECTED PART OF THE WORK. DURING THE CONSTRUCTION PROCESS,IT SHALL BE SOLELY THE CONTRACTOR'S RESPONSIBILITY TO MAINTAINTHE INTEGRITY OF THE EXISTING STRUCTURE AND PROTECT FROMDAMAGING ANY PORTIONS THAT ARE TO REMAIN.13. PERIODIC SITE OBSERVATION BY THE RBA GROUP IS SOLELY FOR THEPURPOSE OF DETERMINING IF THE WORK OF THE CONTRACTOR ISPROCEEDING IN ACCORDANCE WITH THE ARCHITECTURAL CONTRACTDOCUMENTS AND IS NOT EXHAUSTIVE OR CONTINUOUS TO CHECK THEQUALITY OR QUANTITY OF WORK.14. THE CONTRACTOR SHALL SUBMIT FINAL ELEVATOR SHOP DRAWINGSSHOWING ALL LOADS PRIOR TO THE FABRICATION OF THE SUPPORTINGSTRUCTURE.15. THE CONTRACTOR SHALL VERIFY ALL MECHANICAL EQUIPMENTWEIGHTS, LOCATIONS AND ASSOCIATED OPENINGS WITH THEMECHANICAL CONTRACTOR AND SUBMIT SUCH INFORMATION PRIOR TOFABRICATION OF THE SUPPORTING STRUCTURE.16. THE GENERAL CONTRACTOR SHALL REVIEW AND STAMP ALL SHOPDRAWINGS BEFORE SUBMITTING FOR REVIEW. SHOP DRAWINGS SHALLBE SUBMITTED TO THE ARCHITECT AND/OR ENGINEER AND HAVE THEENGINEER'S SHOP DRAWING STAMP AFFIXED PRIOR TO FABRICATION.FABRICATION AND ERECTION SHALL BE FROM REVIEWED SHOPDRAWINGS.17. A RECORD SET OF APPROVED SHOP DRAWINGS SHALL BE KEPT INTHE FIELD BY THE GC.18. THE USE OF ELECTRONIC FILES OR REPRODUCTIONS OF THESECONTRACT DOCUMENTS BY ANY CONTRACTOR, SUBCONTRACTOR,ERECTOR, FABRICATOR, OR MATERIAL SUPPLIER IN LIEU OFPREPARATION OF SHOP DRAWINGS SIGNIFIES THEIR ACCEPTANCE OF ALLINFORMATION SHOWN HEREON AS CORRECT, AND OBLIGATESTHEMSELVES TO ANY JOB EXPENSE, REAL OR IMPLIED, ARISING DUE TOANY ERRORS THAT MAY OCCUR HEREON.19. SPECIAL INSPECTIONS AND TESTING (CHAPTER 17)

A. ALL TESTS AND INSPECTIONS SHALL BE PERFORMED BY ANINDEPENDENT TESTING AND INSPECTION AGENCY. THE SPECIALINSPECTOR FROM THIS TESTING AGENCY SHALL OBSERVE THE WORKFOR CONFORMANCE TO THE DESIGN DRAWINGS AND SPECIFICATIONS.

B. THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTSTO THE BUILDING OFFICIAL, THE ENGINEER OR ARCHITECT OF RECORD,AND ALL OTHER DESIGNATED INDIVIDUALS. ALL DISCREPANCIES SHALLBE BROUGHT TO THE ATTENTION OF THE CONTRACTOR FORCORRECTION, THEN, IF NOT CORRECTED, TO THE PROPER DESIGNAUTHORITY AND TO THE BUILDING OFFICIAL.

C. THE SPECIAL INSPECTOR SHALL SUBMIT A FINAL SIGNEDREPORT STATING WHETHER THE WORK REQUIRING SPECIAL INSPECTIONWAS, TO THE BEST OF THE INSPECTOR'S KNOWLEDGE, IN CONFORMANCEWITH THE APPROVED DESIGN DRAWINGS, SPECIFICATIONS, SOILSREPORT AND APPLICABLE WORKMANSHIP PROVISIONS OF THEAFOREMENTIONED BUILDING CODE.

GENERAL NOTES FIRE RATING KEY

DENOTES 2-HOUR RATED WALLS

DENOTES 2-HOUR RATED WALLS CMU WALLS

DENOTES EXTENT OF 2-HOUR RATED STEELSTRUCTURE TO BE ACHIEVED THROUGH SPRAYAPPLIED FIRE PROOFING OR GWB PER U.L.ASSEMBLIES AS SHOWN ON SHEETS A0.10 - A0.14

ROOM TYPE1ST FLR 2ND FLR 3RD FLR 4TH FLR

KING

KING ACCESSIBLE ROLL-INQUEEN-QUEEN (Q-Q)

COURTYARD

QUEEN - QUEEN ACCESSIBLE ROLL-IN

ONE BEDROOM QUEEN-QUEEN

STUDIORESIDENCE INN

TWO BEDROOM ACCESSIBLE

TWO BEDROOM

5TH FLR

KING ACCESSIBLE

QUEEN-QUEEN ACCESSIBLE ROLL-IN

QUEEN - QUEEN ACCESSIBLE

QUEEN-QUEEN ACCESSIBLE

170

KING AKING B

ROOM NUMBERS

KING CKING D

STUDIO ASTUDIO BSTUDIO CSTUDIO DSTUDIO ESTUDIO FSTUDIO G ACCESSIBLE ROLL-INONE BEDROOM QUEEN

ONE BEDROOM QUEEN-QUEEN A

TWO BEDROOM ATWO BEDROOM B

172

171

169, 167, 165

168

166, 164

163, 161

162

272

271

269, 267, 265

270, 268, 266, 264, 262, 260,258, 256, 254, 252, 250

263, 261, 259, 257, 255

253

248246

239, 240, 242, 244

241

201 - 208, 233, 234

209 - 220, 222, 224

226

228

230

232

235

236, 238

237

372

371369, 367, 365

370, 368, 366, 364, 362, 360,358, 356, 354, 352, 350

363, 361, 359, 357, 355

353

348346

341

301 - 308, 333, 334

309 - 320, 322, 324

326

328

330

332335, 337

336,338

471

472

469, 467, 465

470, 468, 466, 464, 462, 460,458, 456, 454, 452, 450

463, 461, 459, 457, 455453

448446

441

401 - 408, 428, 433, 434

409 - 420, 422, 424

426430

432435, 437

436, 438

571

572

569, 567, 565

570, 568, 566, 564, 562, 560,558, 556, 554, 552, 550

563, 561, 559, 557, 555

553

548546

541

501 - 508, 533, 534

509 - 520, 522, 524

526

528

530

532535, 537

536, 538

339, 340, 342, 344 439, 440, 442, 444 539, 540, 542, 544

ENLARGED PLAN

1/A5.501/A5.501/A5.501/A5.513/A5.51

1/A5.521/A5.53

1/A5.54

1/A5.551/A5.56

1/A5.60

1/A5.611/A5.62

3/A5.624/A5.62

DETAIL/SHEET

1/A5.631/A5.641/A5.65

1/A5.661/A5.671/A5.681/A5.691/A5.691/A5.701/A5.711/A5.721/A5.73

ALL

DES

IGN

S, D

RA

WIN

GS

AN

D S

PEC

IFIC

ATI

ON

S D

EPIC

TED

ON

TH

IS S

HEE

T A

RE

TH

E P

RO

PER

TY O

F T

HE

R B

A G

RO

UP,

IN

C.

A

NY

UN

AU

THO

RIZ

ED

USE

OR

REP

RO

DU

CTI

ON

IS

SU

BJE

CT

TO

LEG

AL

PR

OSE

CU

TIO

N.

POSS

ESSI

ON

IN

AN

Y F

OR

M C

ON

STIT

UTE

S A

CC

EPTA

NC

E O

F T

HES

E C

ON

DIT

ION

S.

C

OPY

RIG

HT

201

3

DRAWN BY

CHECKED BY

PROJECT DATE

PROJECT NUMBER

DATEREVISION

DRAWN BY

CHECKED BY

PROJECT DATE

PROJECT NUMBER

dateREVISION

no. comment

1 4 1 4 - A S . T R Y O N S TC H A R L O T T E , N C 2 8 2 0 3T E L :: 7 0 4 . 3 4 4 . 9 0 9 8

COURTYARD &RESIDENCE INN

by MARRIOTTRALEIGH, NC

ISSUE DATE: 07.18.13

ZDS

CA

07.18.13

13-1468

FOR CONSTRUCTION

OWNER SET #7FRANCHISE SET #2BID SET #2BUILDING DEPT #1FIRE MARSHAL #0HEALTH DEPT #2

1234567

SREE Hotels5113 Piper Station Drive, Suite 300

Charlotte, NC 28277

07.18.2013

FIFTH FLOORDIMENSION PLAN -

SIDE A

A2.50