A universal solution for Intelligent Motor Control Centers · Kolkata: +91 33 22275850/51 +91 33...

Post on 29-Jul-2020

0 views 0 download

Transcript of A universal solution for Intelligent Motor Control Centers · Kolkata: +91 33 22275850/51 +91 33...

44, Okhla Industrial Estate, Phase -III, New Delhi -110 020 (INDIA) Phone : +91 11- 66602414, 30883745/54/64 Fax: +91 11- 6660 2413 E-mail: cspc@cselectric.co.in

Branch office

Branch Phone Fax E-mail

Ahmedabad: +91 79 30074534/35/36 +91 79 30074519 cspc.ahmedabad@cselectric.co.in

Bangalore: +91 80 3057 0372/73, 3057 0347 +91 2558 4839 cspc.bangalore@cselectric.co.in

Bhubaneswar: +91 674 2507265 +91 674 2507265 cspc.bhubaneswar@cselectric.co.in

Chennai: +91 44 3918 0531-35 +91 44 39180514 cspc.chennai@cselectric.co.in

Cochin: +91 0484 3071717 +91 0484 3071716 cspc.cochin@cselectric.co.in

Delhi: +91 11 30838822-25 +91 11 30838826 cspc.delhi@cselectric.co.in

Hyderabad: +91 40 3918 2496/97 +91 40 3910 3631 cspc.hyderabad@cselectric.co.in

Kolkata: +91 33 22275850/51 +91 33 2227 5849 cspc.kolkata@cselectric.co.in

Mumbai: +91 22 30487146/47/48 +91 22 2412 6631 cspc.mumbai@cselectric.co.in

Pune: +91 20 30283244/45 +91 20 30283244 cspc.pune@cselectric.co.in

A universal solution for Intelligent Motor Control Centers

C&S Electric Limited

- III

Application:

Unique Features

Water Pumping / Treatment plant , HVAC, Power Plant, Cement Plants, Steel Plant, Chemical & Fertilizer Plants many others that needs intelligent motor control operation.

:

Integrated Solution (Protection, Monitoring, Fault Recording, Sequence & Control Function)

Suitable for Interface with PLC, DCS, Remote Control from SCADA

Current Range – 0.125 A to 1000 A

5 Starting Mode (DOL, Star Delta, F/R, Resistance & Reactance, Soft Starting)

Auto Restart on Voltage Recovery after Inst. Under voltage Condition,

User Point Control Contact for ON/ OFF Delayed operation

Self Supervision & Contactor Supervision

Communication – RS 485 on MODBUS / 4-20mA output (only monitoring)

5 modes for Motor Control Operation (LOP, MCC, AUTO,W/L, REMOTE)

l

l

l

l

l

l

l

l

l

2 3

Easy and convenience installation

It can be checked fault analysis and operated motor by inserting the main unit into panel. It°Øspossible to set current/operating time/various function easily by simple button. And it can be alsocomposed of compact MCC, minimized wiring work, so user can reduce labor cost.

n Load under 0.5A- Set the CT ratio 0.5 or 0.25 in the [6.ctr]- MCT cable penetration increase from 2 times to 4 times- Rated current setting range : 0.25~3A(2 times), 0.125~1.5A (4 times)

Over 60A load- Usage of external CT- CT ratio (1~200) : Maximum 1000A

n

Information

Self-supervision and contactor failure function

Total operation time setting and storage

IMC-III can be checked self-supervision like a memory fault. When the motor starts/stops, that indicates Error.No and turn on Sys.Fail LED by supervising Input/output condition.

It can be stored motor operation time up to 10 years. Continuous operation time can be stored and setting.

Communication functionIts possible to communicate with other system and organize various communication Network by MODBUS/RS-485. And its also possible to communicate with system by Analog current signal(4~20mA). So that makes it possible to interchange by using TD(Transducer).

Digital ampere-meterIt It can be monitored indication of R, S, T current, and load ratings(%) by Bar LED

Fault analysis and Recording

It can be indicated fault cause and fault current value by 7-segment and LED. At the moment of instantaneous stopping of power supply, it can solve the problem. Because of the fault storage.

Wide current setting range : 0.125A~1000A within 1 modelIt can be changed from 0.5~6A to 5~60A by slide S/W, the current can be changed to 0.125Aup to MCT number of the time of penetrating current line.

* External CT : Note p22 (option)* MCT : Molded current transformer(Enclosing with product)

External CT 2 times(0.25~3A) A group " 5.ctr 0.5 setting

4 times(0.125~1.5A) A group " 5.ctr 0.25 setting

Main Characteristic Monitoring & Fault Record

4 5

Ω

µ

_+

x

x x

x

Function Technical Parameters

>

_+

_+

x

x

6 7

Ω

φ

Accessories

ZCT(Zero-phase current transformer)

System Configuration