Post on 29-May-2020
A
2
Four-wire Signal Conditioners
Two-wire Signal Conditioners
Power Transducers
Indicators
Limit Alarms
Gateway,Remote I/O
Paperless RecordingSystem
PC Recorder
Electronic Actuators& Position Sensors Lightning Surge Protectors
Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1
Mini-M Series
Mini-MW Series
M6 Series
M5-UNIT Series
W5-UNIT Series
M3-UNIT Series
M3S-UNIT Series
Pico-M Series
MX-UNIT Series
M-UNIT Series
W-UNIT Series
K-UNIT Series
F-UNIT Series
H-UNIT Series
10-RACK Series
18-RACK Series
38-RACK Series Rack
-mou
nted
AFour-wire Signal Conditioners
Two-wire Signal Conditioners
Power Transducers
Indicators
Limit Alarms
Gateway,Remote I/O
Paperless RecordingSystem
PC Recorder
Electronic Actuators& Position Sensors
Lightning Surge Protectors
3
Mini-M Series
Mini-MW Series
M6 Series
M5-UNIT Series
W5-UNIT Series
M3-UNIT Series
M3S-UNIT Series
Pico-M Series
MX-UNIT Series
M-UNIT Series
W-UNIT Series
K-UNIT Series
F-UNIT Series
H-UNIT Series
10-RACK Series
18-RACK Series
38-RACK SeriesRack
-mou
nted
Specifications are subject to change without notice.ISP1-1
Four
-wire
Sig
nal C
ondi
tione
rs
Four
-wire
Sig
nal C
ondi
tione
rs
Four-wire Signal Conditioners Product Selection Guide
Four-wire Product Selection Guide
Four-wire Product Selection Guide
mm (inch)
Compact Plug-in Mini-M Series
Compact Plug-in Signal Splitters Mini-MW Series
Ultra-Slim M6 Series
Low Profile M5-UNIT Series
Low Profile Signal Splitters W5-UNIT Series
Thin Profile M3-UNIT Series
Thin Profile M3S-UNIT Series
P.8 P.30 P.38 P.56 P.60 P.64 P.68
Construction Plug-in Plug-in Ultra-slim Terminal block Terminal block Front terminal access Front terminal access
Connection M3 screw terminal M3 screw terminal Tension-clamp, M3 screw terminal Euro terminal M3.5 screw terminal Input: M3.5 screw terminal
Output & power: M3 screw terminal Removable terminal block Removable terminal block
Isolation Three ways Four ways Three / four ways Three ways Four ways Three ways Three / Four ways
Dielectric Strength 2000V AC 2000V AC 2000V AC DC powered: 2000V AC AC powered: 1500V AC 2000V AC DC powered: 1000V AC
AC powered: 1500V AC (M3LU) 2000V AC
Range Selectability Specified when ordering or PC / One-Step Cal programming
Specified when ordering or PC programming
Specified when ordering or PC programming Specified when ordering Specified when ordering or
DIP switch programming PC / One-Step Cal programming Specified when ordering or PC programming
Dual Output – Yes Selected models – Yes – Selected models
Power Input AC / DC AC / DC DC AC / DC AC / DC AC / DC AC / DC (universal)
Operating Temperature -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F) -20 to +55°C (-4 to +131°F) -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F) -25 to +65°C (-13 to +149°F) -10 to +55°C (14 to 131°F)
Mounting Surface or DIN rail Surface or DIN rail DIN rail DIN rail DIN rail DIN rail DIN rail
Dimensions W23 [29.5] × H76 × D124 mm (0.91” [1.16”] × 2.99” × 4.88”)
W29.5 × H89 × D124 mm (1.16” × 3.51” × 4.88”)
M6D/S: W5.9 × H94 × D102 mm (0.23” × 3.70” × 4.02”) M6N: W7.5 × H102 × D102 mm (0.30” × 4.02” × 4.02”)
W25 × H97 × D41 mm (0.98” × 3.82” × 1.61”)
W45 × H97 × D41 mm (1.77” × 3.82” × 1.61”)
W18 × H106 × D110.5 mm (0.71” × 4.17” × 4.35”)
W12 × H106 × D110.5 mm (0.47” × 4.17” × 4.35”)
Standards & Approvals CE / UL / C-UL CE / UL / C-UL CE (UL / C-UL pending) CE CE CE / UL / C-UL (DC powered only) CE
Mini-M Series Mini-MW Series M6 Series M5-UNIT W5-UNIT M3-UNIT M3S-UNIT
Input Loop Powered Isolator M2SN – M6xSN M5SN – – –Universal Input M2XU, M2XUM – – – – M3LU –
DC Input M2XV2, M2LV, M2VS, M2VF, M2VF2, M2VV W2VS, W2VF M6xYV, M6xXV, M6xVS,
M6xWVS M5VS, M5MV, M5VF W5VS, W5FV M3LV M3SYV, M3SXV, M3SVS, M3SWVS
High Current Output – – – – – – –Thermocouple Input M2XT2, M2TS W2TS M6xXT M5TS W5TS M3LT M3SXT
RTD Input M2XR2, M2LR, M2RS, M2RR W2XR, W2RS M6xXR M5RS W5RS M3LR M3SXR, M3SRSPotentiometer Input M2XM2, M2LPM, M2MS W2XM, W2MS M6xXM M5MS W5MS M3LM M3SXM, M3SMS
Current Loop Supply M2D, M2D2, M2DYS, M2DY, M2DL, M2DNY, M2DYH, M2DU
W2DYS, W2DY, W2DNY, W2DYH M6xDY M5DY W5DY M3LDY, M3DY M3SDY
Self-Synch Input – – – – – – –Strain Gauge Input M2LCS – – – W5LCS M3LLC –
AC Input M2TG, M2AC W2TG, W2AC – – – – –PT Input M2PA, M2PE W2PA, W2PE – M5PT – – –CT Input M2CA, M2CE, M2CEC W2CA, W2CE M6xCTC M5CT, M5CTC – – –
Power Transducer – – – – – – –Frequency Input M2XPA3, M2XPA2, M2SP W2SP M6xPA M5PA W5PA M3LPA –Encoder Input M2XRP2 – – – – – –
Frequency Output M2AP W2AP – – – – –Pulse Isolator M2PP W2PP – – – – –Pulse Scaler M2PRU – – – – – –
P/I Transducer M2PV W2PV – – – – –I/P Transducer – – – – – – –
Limit Alarm M2AVS, M2SED, M2AS, M2AS1 – M6xXAS – – – –BCD Transducer – – – – – – –Math Function M2ADS, M2SBS, M2MLS, M2DIS – M6xXF2 – – – –
Ratio/Bias M2REB, M2RTS – – – – – –
Process Function M2XF2, M2FL, M2FLS, M2LMS, M2UDS2, M2UDS – M6xXF1 – – – –
Filter/Lag M2CDS, M2CRS – M6xXF1 – – – –
Hold M2AMS2, M2AMS, M2PHS2, M2PHS – M6xXF3 – – – –
Signal Selector M2SES2, M2SES, M2MNV – M6xXF2 – – – –Signal Generator M2MST – – – – – –Valve Positioner – – – – – – –Control Backup – – – – – – –
Others – – – – – – –
Four-wire Signal Conditioners Product Selection Guide
A
4
Four-wire Signal Conditioners
Two-wire Signal Conditioners
Power Transducers
Indicators
Limit Alarms
Gateway,Remote I/O
Paperless RecordingSystem
PC Recorder
Electronic Actuators& Position Sensors Lightning Surge Protectors
Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1
Mini-M Series
Mini-MW Series
M6 Series
M5-UNIT Series
W5-UNIT Series
M3-UNIT Series
M3S-UNIT Series
Pico-M Series
MX-UNIT Series
M-UNIT Series
W-UNIT Series
K-UNIT Series
F-UNIT Series
H-UNIT Series
10-RACK Series
18-RACK Series
38-RACK Series Rack
-mou
nted
AFour-wire Signal Conditioners
Two-wire Signal Conditioners
Power Transducers
Indicators
Limit Alarms
Gateway,Remote I/O
Paperless RecordingSystem
PC Recorder
Electronic Actuators& Position Sensors
Lightning Surge Protectors
5
Mini-M Series
Mini-MW Series
M6 Series
M5-UNIT Series
W5-UNIT Series
M3-UNIT Series
M3S-UNIT Series
Pico-M Series
MX-UNIT Series
M-UNIT Series
W-UNIT Series
K-UNIT Series
F-UNIT Series
H-UNIT Series
10-RACK Series
18-RACK Series
38-RACK SeriesRack
-mou
nted
Specifications are subject to change without notice.ISP1-1
Four
-wire
Sig
nal C
ondi
tione
rs
Four
-wire
Sig
nal C
ondi
tione
rs
Four-wire Signal Conditioners Product Selection Guide
Four-wire Product Selection Guide
Four-wire Product Selection Guide
mm (inch)
Dual Output Super-mini Signal Conditioners
Pico-M SeriesPlug-in Front Configurable
MX-UNIT SeriesPlug-in
M-UNIT SeriesPlug-in Signal Splitters
W-UNIT SeriesPlug-in
K-UNIT SeriesSpace-saving Plug-in
F-UNIT SeriesSpace-saving Plug-in
H-UNIT Series
Construction Connector on the base Plug-in Plug-in Plug-in Plug-in Plug-in Plug-in
Connection M3.5 screw terminal, DCS M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal
Isolation Four ways Three ways Three ways Four ways Three / four ways Three ways Three ways
Dielectric Strength 1500V AC 2000V AC 2000V AC 2000V AC 2000V AC 1000V AC 500V AC
Range Selectability Specified when ordering or PC programming Front key programming Specified when ordering or
PC / Programming unit programmingSpecified when ordering or
PC / Programming unit programming Specified when ordering Specified when ordering or PC / Programming unit programming
Specified when ordering or PC / Programming unit programming
Dual Output Yes – – Yes Selected models – –
Power Input AC / DC AC / DC AC / DC AC / DC AC / DC AC / DC DC
Operating Temperature 0 to 55°C (32 to 131°F) -5 to +55°C (23 to 131°F) -5 to +60°C (23 to 140°F) -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F)
Mounting Installation Base (Surface) Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail
Dimensions W17.5 × H48 × D75 mm (0.69” × 1.89” × 2.95”)
W50 × H80 × D123 [132] mm (1.97” × 3.15” × 4.84” [5.20”] )
W50 × H80 × D127 [136] mm (1.97” × 3.15” × 5” [5.35”] )
W50 × H80 × D136 mm (1.97” × 3.15” × 5.35”)
W50 × H80 × D123 [132] mm (1.97” × 3.15” × 4.84” [5.20”] )
W26 × H100 × D137 mm (1.02” × 3.94” × 5.39”)
W26 × H93 × D137 mm (1.02” × 3.66” × 5.39”)
Standards & Approvals CE CE CE / UL / C-UL for selected models CE for selected models CE for selected models – –
Pico-M Series MX-UNIT M-UNIT W-UNIT K-UNIT F-UNIT H-UNIT
Input Loop Powered Isolator – – SN – KSN FSN HSNUniversal Input – – JUA – – – –
DC Input M8YV1, M8XV3, M8VS1, M8YS1, M8YC1 MXV, MXF JV, SV, SVF, CV, OT2, OR2 WJV, WVS, WVS2, WVF KYV, KVS, KWVS,
KWVS2, KSF, KV FJV, FVS, FVF, FV HJV, HVS, HVF, HV
High Current Output – – VA, SVA, 99SVA – – – –Thermocouple Input M8XT3, M8TS1 MXT JT, TCS, OTT2, OTR2 WJT, WTS KTS, KWTS FJT, FTS HJT, HTS
RTD Input M8XR3, M8RS1 MXR JR, RB, RBS, DR, DRS, CVRTD WJR, WRS, WRS2 KR, KRS, KWRS, KWRS2 FJR, FR, FRS HJR, HR, HRSPotentiometer Input M8XM3, M8MS1 – JM, PM, PMS, CVR1 WJM, WMS, WMS2 KM, KMS, KWMS, KWMS2 FJM, FM, FMS HJM, HM, HMS
Current Loop Supply M8DY1 – DS, DS-48, JDL, YVD, YVDU, FND, FNDS WDY, WDNY KD, KDY, KWDY, KWDNY,
KWLD FD, FJDL, FDY2, FDL, FDU HD, HJDL, HDY2, HDL, HDU
Self-Synch Input – MXS JS WJS – – –Strain Gauge Input M8LCS MXLC, MXLCF LC, LCS, LC2, LCS2, LCF, MLV – KG, KGS FLC, FLCS –
AC Input – – TG, AC WTG, WAC KTG, KAC FTG, FAC –PT Input M8PT – PT, PTPH, PTAF WPT KP, KPE, KPNA, KPNE FPA, FPE HPA, HPE
CT Input M8CT1, M8CTC – CTH, CTC, CTCS, CTS, CT, CTPH,CTAF WCT KCEC, KC, KCE,
KCNA, KCNE, KCEZ FCA, FCE HC, HCE
Power Transducer – – MUWT, MEWT, MEWTF, MERP, MEPF, MEPA, HZ
WEWT, WERP, WEPF, WEPA, WHZ – – –
Frequency Input M8PA1 MXPA JPA, JPA2, MPAU, JPQ2, EP, SP, JTY2 WJPAD, WJPA, WSP KEP, KSP, KPAU FJPA, FSP HJPA, HSPEncoder Input – – JRP2, JRQ2, RPPD, JARP – – – –
Frequency Output M8AP1 MXAP AP, APU, JAPD, JARP, MTD – KAP, KAPU FAP HAP, HAPUPulse Isolator M8PP1 – PP, PPD, YPD, RPPD, MNS WYPD KMT, KYPD, KWYPD FPP HPPPulse Scaler – – JPR2, PRU, JFR2, PDU, JPS3, JPS2 – KPRU – HPR
P/I Transducer – – PV – – – HPVI/P Transducer – – VP – – – HVP, HVPN
Limit Alarm M8SED1 –AS4V, AS4T, AS4R, AS4M, AS4CT,
AS4LC, MSEF, AS, ASW, ASW2, ASL, ASWL, ASWL2, AYAV, AYDV, ASD1, ASD
– KS2V, KS2TR, KSED, KSE, KS, KS2, KSL, KSL2 FAS, FASD HAS
BCD Transducer – – AD3V, AD2LC, DA3 – – – –Math Function – – JF, JFK, ADS, SBS, MLS, DIS WJF, WJFK, WADS KADS, KSBS, KMLS, KDIS FJF HJF
Ratio/Bias – – REB, REBS, RT, RTS – KB, KBS FRT, FRTS, FRTD –
Process Function – MXF JFX, JFX1, FN, FNS, LM, LMS, UD, UDS, MLG WJFX KX, KN, KNS, KL, KLS, KU, KUS FJFX, FFL, FLM, FLMS, FUD,
FUDS HJFX, HN
Filter/Lag M8CD1 – JFT, JFTS, CD, CDS, CR, CRS WJFT KF, KFS FJFT, FCR, FCRS HJFTHold – – AM, AMS, PH, PHS – KA, KAS, KH, KHS – –
Signal Selector – – SE, SES, MNV – – FSE, FSES –Signal Generator – MXMS MS, MFS, MFS2 – – – –
Valve Positioner – – ABM, MP, MEX-B, MEX-C, MEX-D, MEX-E, MEX-F, MEX-M1 – – – –
Control Backup – MXAB, MXCB JB2, AB2, CB2 – – – –Others – – MDC (Excitation Supply) – – – –
Four-wire Signal Conditioners Product Selection Guide
A
6
Four-wire Signal Conditioners
Two-wire Signal Conditioners
Power Transducers
Indicators
Limit Alarms
Gateway,Remote I/O
Paperless RecordingSystem
PC Recorder
Electronic Actuators& Position Sensors Lightning Surge Protectors
Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1
Mini-M Series
Mini-MW Series
M6 Series
M5-UNIT Series
W5-UNIT Series
M3-UNIT Series
M3S-UNIT Series
Pico-M Series
MX-UNIT Series
M-UNIT Series
W-UNIT Series
K-UNIT Series
F-UNIT Series
H-UNIT Series
10-RACK Series
18-RACK Series
38-RACK Series Rack
-mou
nted
AFour-wire Signal Conditioners
Two-wire Signal Conditioners
Power Transducers
Indicators
Limit Alarms
Gateway,Remote I/O
Paperless RecordingSystem
PC Recorder
Electronic Actuators& Position Sensors
Lightning Surge Protectors
7
Mini-M Series
Mini-MW Series
M6 Series
M5-UNIT Series
W5-UNIT Series
M3-UNIT Series
M3S-UNIT Series
Pico-M Series
MX-UNIT Series
M-UNIT Series
W-UNIT Series
K-UNIT Series
F-UNIT Series
H-UNIT Series
10-RACK Series
18-RACK Series
38-RACK SeriesRack
-mou
nted
Specifications are subject to change without notice.ISP1-1
Four
-wire
Sig
nal C
ondi
tione
rs
Four
-wire
Sig
nal C
ondi
tione
rs
Four-wire Signal Conditioners Product Selection Guide
Four-wire Product Selection Guide
Four-wire Product Selection Guide
mm (inch)
Dual Output 10-RACK Series
DCS Front End 18-RACK Series
Interposing Relays 38-RACK Series
Construction Rack-mounted Rack-mounted Rack-mounted
Connection M3.5 screw terminal, DCS M3.5 screw terminal, DCS M3.5 screw terminal
Isolation Four ways Four ways –
Dielectric Strength 500V AC 1500V AC –
Range Selectability Specified when ordering or PC / Programming unit programming
Specified when ordering or PC / Programming unit programming –
Dual Output Yes Yes –
Power Input AC / DC AC / DC DC
Operating Temperature -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F)
Mounting Standard rack Standard rack Standard rack
Dimensions W25 × H99 × D180 mm (0.98” × 3.90” × 7.09”)
W24 × H110 × D110 mm (0.94” × 4.33” × 4.33”)
W24 × H110 × D110 mm (0.94” × 4.33” × 4.33”)
Standards & Approvals – – –
10-RACK 18-RACK 38-RACK
Input Loop Powered Isolator 10SN 18SNUniversal Input – –
DC Input 10VS4, 10YS, 10YK, 10JV, 10VS, 10VK, 10VF
18YS, 18YK, 18YC, 18JV, 18VS, 18VK
High Current Output – –Thermocouple Input 10JT, 10TS, 10TK 18JT, 18TS, 18TK
RTD Input 10JR, 10JRE, 10RS, 10RK 18JR, 18RS, 18RKPotentiometer Input 10JM, 10MS, 10MK 18JM, 18MS, 18MKCurrent Loop Supply 10D, 10JDL, 10DY, 10DNY, 10DU 18JDL, 18DY, 18JDN, 18DU
Self-Synch Input – –Strain Gauge Input 10LCS, 10LCK –
AC Input 10TG, 10AC 18TG, 18ACPT Input 10PA, 10PE 18PECT Input 10CA, 10CE 18CE
Power Transducer 10EWT, 10ERP, 10EPF, 10EPA, 10EHZ 18WT, 18RP, 18PF, 18PA, 18HZFrequency Input 10JPA, 10SP 18JPAEncoder Input – –
Frequency Output 10AP –Pulse Isolator 10PP 18PPPulse Scaler 10PR 18PR
P/I Transducer 10PV 18PVI/P Transducer 10VP, 10VPN 18VP
Limit Alarm 10AS 18AS2, 18AT, 18ARBCD Transducer – –Math Function 10JF 18JF
Ratio/Bias – –Process Function 10JFX, 10FNS 18JFX, 18JN
Filter/Lag 10JFT –Hold – –
Signal Selector – –Signal Generator – –Valve Positioner – –Control Backup 10ABS –
Others 10BOS 18DI, 18DO, 18APT, 18YVT
Visit M-System Web Site.
Four-wire Signal Conditioners Product Selection Guide
n PC Configurator SoftwareM-System’s PC Configurator programs are packed with advanced features. Not only the I/O ranging, but also linearization, fine calibration, filters, diagnostics are available depending on the signal conditioner’s function. In addition, many configurators are provided with monitoring and simulating functions to help you confirm the module’s proper operation, calibrate it at the field site and commissioning the receiving instrument at the same time.
This type of programming is especially convenient when an identical configuration setting is required for multiple modules. It saves you a considerable time by simply calling a pre-defined setting and downloading it from the PC software.
The PC configuration is available with various signal conditioner series including M2X, M3L, M3SX and M6X Series.
n “One-Step Cal” ConfigurationEven when you do not have a PC at your disposal, a simulator and a multimeter can help you program I/O ranges.
The internal DIP switches are used to configure input and output type. Once the module is configured, precise ranges can be set with the front control buttons using a simulator connected to the input terminals and a multimeter connected to the output terminals as a reference.
For example, suppose that the DIP switches are configured for the J type thermocouple. Turn the power supply to the transmitter on and press MODE button to enter to the Input Calibration Mode. Apply the desired minimum (e.g. 0°C) and maximum (e.g. 400°C) input levels and push the DOWN (zero) and UP (span) respectively to set the input range to 0 to 400°C. Then the output range can be calibrated in a similar manner after moving to the Output Calibration Mode.
The front LED’s colors and flashing patterns help you easily identify the transmitter’s status and confirm the setup actions in each step of Calibration Modes.
“One-Step Cal” configuration is available with the M3L and M2L Series signal conditioners.
n Front Control Buttons with Local DisplayThe MX Series signal conditioners and the AS4 Series limit alarms are provided with two displays on the front face: 4-digit DATA display and 2-digit ITEM display. Using Up/Down buttons, configuration is simple by calling parameters’ ID numbers (ITEM) and choosing values (DATA).
The M7E Series limit alarms are provided with a multi-line LCD display, which shows the parameters and selections in text to guide you through the programming procedure: intuitive, easy programming just like operating your mobile phone. You won’t need to consult the instruction manual.
These displays indicate process values once commissioned at the field site, and the soft-ware’s “programmable” mode can be locked out in order to prevent unwanted changes in the setting.
Configurable Signal Conditioners — Choose your way of configuration.
Basic Setting View Trend Graph View
MODE Button
DOWN Button
UP Button
LCD Display
Mode Button
Set Button
PC ConfiguratorJack
Up Button
Down ButtonITEM No. Display
DATA UP-DOWN Keys
ITEM No. UP-DOWN Keys
DATA Display
ProgrammingError LED
Polarity LED
MX Series Front Panel M7E Series Front Panel
Connect the M3LU to a simulator and a multimeter and to a power source.
SimulatorMultimeter
Power Source
Input Output
M3SX Series
M3L Series Front Panel
B
76
Four-wire Signal Conditioners
Two-wire Signal Conditioners
Power Transducers
Indicators
Limit Alarms
Gateway,Remote I/O
Paperless RecordingSystem
PC Recorder
Electronic Actuators& Position Sensors Lightning Surge Protectors
Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1
Two-wire Product Selection Guide
27-UNIT Series
26-UNIT Series
B6-UNIT Series
B3-UNIT Series
B5-UNIT Series
6-UNIT Series
T-UNIT Series
B-UNIT Series
Two-
wire
Sig
nal C
ondi
tione
rs
Two-wire Signal Conditioners Product Selection Guide BFour-wire Signal Conditioners
Two-wire Signal Conditioners
Power Transducers
Indicators
Limit Alarms
Gateway,Remote I/O
Paperless RecordingSystem
PC Recorder
Electronic Actuators& Position Sensors
Lightning Surge Protectors
77
Two-wire Product Selection Guide
Two-wire Signal Conditioners Product Selection Guide
27-UNIT Series
26-UNIT Series
B6-UNIT Series
B3-UNIT Series
B5-UNIT Series
6-UNIT Series
T-UNIT Series
B-UNIT Series
Two-
wire
Sig
nal C
ondi
tione
rs
Specifications are subject to change without notice.ISP1-1
Head-mount, Programmable 27-UNIT Series
Head-mount 26-UNIT Series
Field-mount B6-UNIT Series
DIN Rail Mount B3-UNIT Series
Low Profile B5-UNIT Series
Hockey-puck Style 6-UNIT Series
Compact Size T-UNIT Series
Space-saving, Plug-in B-UNIT Series
P.78 P.82 P.84 P.86 P.90
Construction Sensor head-mounting Sensor head-mounting Outdoor enclosure (IP65) Front terminal access Terminal block Hockey-puck style Stand-alone; terminal access at the front Plug-in
Connection M3 screw terminal Terminal block M3.5 screw terminal Removable terminal block M3.5 screw terminal M3 screw terminal DIN terminal block M3.5 screw terminal
Isolation Input to output Input to output Input to output to outdoor enclosure Input to output Input to output Input to output Input to output Input to output
Dielectric Strength 1500V AC 1500V AC 1500V AC 2000V AC 2000V AC 500V AC 500V AC 500V AC
Range Selectability PC or HART programming Specified when ordering HART (PC) programmingSpecified when ordering or HART (PC) / PROFIBUS-PA
(PC) / DIP switch programmingSpecified when ordering Specified when ordering or
DIP switch programming Specified when ordering Specified when ordering
Operating Temperature -40 to +85°C (-40 to +185°F)
-40 to +85°C (-40 to +185°F)
-40 to +85°C (-40 to +185°F)
-40 to +85°C(-40 to +185°F)
-40 to +80°C (-40 to +176°F)
-5 to +70°C (23 to 158°F)
-5 to +60°C (23 to 140°F)
-5 to +55°C (23 to 131°F)
Mounting Head mount or Field mount Head mount Field mount DIN rail DIN rail DIN rail
with mounting plate A-31 Surface or DIN rail Surface or DIN rail
Dimensions 44 dia. × 20.7 mm (1.732 dia. × 0.81”)
43.5 dia. × 26.5 mm (1.71 dia. × 1.04”) 110 (4.33”) dia. W18 × H106 × D110.5 mm
(0.71” × 4.17” × 4.35”)W25 × H97 × D41 mm (0.98” × 3.82” × 1.61”)
W76 × H52.5 × D61 mm(2.99” × 2.07” × 2.40”)
W25 × H60 × D70 mm (0.98” × 2.36” × 2.76”)
W26 × H93 × D137 mm (1.02” × 3.66” × 5.39”)
Standards & Approvals CE / ATEX / FM / SIL2 CE / ATEX CE / ATEX / FM / SIL CE / UL / C-UL / ATEX / FM CE – – –
27-UNIT 26-UNIT B6-UNIT B3-UNIT B5-UNIT 6-UNIT T-UNIT B-UNIT
Input Loop Powered Isolator – – – – B5SN 6SN TSN BSN
DC Input – – – B3VS/1 (single channel) B3VS/2 (dual channel) B5VS – TV, TVS BV, BVS
DC Input (programmable) – – – B3FV – 6VS – –
Universal Temperature Input(HART, outdoor enclosure) 27HU-B – B6U-B – – – – –
Universal Temperature Input (HART) 27HU – B6U B3HU – – – –
Universal Temperature Input (PROFIBUS-PA) – – – B3PU – – – –
Universal Temperature Input 27U – – – – – – –Thermocouple Input – 26TS1 – – B5TS 6TS – BT, BTSThermocouple Input
(programmable) 27TS – – B3FT – 6TS1 – –
RTD Input – 26REX, 26R1, 26RS – – B5RS – TR BRRTD Input
(programmable) 27R, 27RS – – B3FR – 6R – –
Potentiometer Input – – – – B5MS 6M TM BMStrain Gauge Input – – – – – 6LC – BLC
Frequency Input – – – – – – – BSPFrequency Input (programmable) – – – B3FP – 6PA – –
Square Root Extractor – – – – – 6FN – –AC Input – – – – – 6AC – –PT Input – – – – – 6PT – BPTCT Input – – – – – 6CT – BCT
P/I Transducer – – – – – – TPV BPV
6BX-E
C
94
Four-wire Signal Conditioners
Two-wire Signal Conditioners
Power Transducers
Indicators
Limit Alarms
Gateway,Remote I/O
Paperless RecordingSystem
PC Recorder
Electronic Actuators& Position Sensors Lightning Surge Protectors
Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1
Power TransducersProduct Selection Guide
LT-UNIT Series
53U / 52U / 51U
LSMT3
LSMT2
K-UNIT Series
CLS Series
Power Transducers Products Selection Guide
L-UNIT Series
Pow
er T
rans
duce
rs
CFour-wire Signal Conditioners
Two-wire Signal Conditioners
Power Transducers
Indicators
Limit Alarms
Gateway,Remote I/O
Paperless RecordingSystem
PC Recorder
Electronic Actuators& Position Sensors
Lightning Surge Protectors
95
Power TransducersProduct Selection Guide
Power Transducers Products Selection Guide
LT-UNIT Series
53U / 52U / 51U
L-UNIT Series
LSMT3
K-UNIT Series
LSMT2
Pow
er T
rans
duce
rs
Specifications are subject to change without notice.ISP1-1
Multi Power Transducer LSMT3
Multi Power Transducer LSMT2
Construction Terminal access at the front Terminal access at the front
Connection Connector type screw terminal block
Input and aux. supply: M4 screw terminal,
Output: M3.5 screw terminal
Dielectric Strength 3700V AC 2000V AC
Auxiliary Power AC / DC (universal) AC / DC
Operating Temperature -10 to +55°C (14 to 131°F)
-10 to +55°C (14 to 131°F)
Mounting DIN rail Surface or DIN rail
Dimensions W105 × H69.1 × D112.5 mm(4.13” × 2.72” × 4.43”)
W120 × H100 × D128 mm(4.72” × 3.94” × 5.04”)
Standars & Approvals CE –
Configuration
Single phase 3-phase / 3-wire balanced / Unbalanced load3-phase / 4-wire balanced / Unbalanced load
••
•
3-phase / 3-wire Single-phase / 2-wireSingle-phase / 3-wire3-phase / 4-wire
••••
Output Analog output, 3 points
Current Voltage
4 – 20mA DC0 – 1mA DC
0 – 10V DC0 – 5V DC1 – 5V DC
Watthours
Multi Power Monitor 53U
P.104
Construction 96-mm square (1/4 DIN size)
Connection;Voltage input Connector type terminal block
Dielectric Strength 2500V AC
Auxiliary Power AC / DC (universal)
Operating Temperature -10 to +55°C (14 to 131°F)
Mounting Panel Flush Mounting
Dimensions W96 × H96 × D115 mm (3.78” × 3.78” × 4.53”)
Degree of protection IP 50 (Front panel)
Standards & Approvals CE
Configuration Single-phase / 2-wire and 3-wire,3-phase / 3-wire and 4-wire
External Interface
Modbus, Do × 1, Di × 14 – 20mA DC × 41 – 5V DC × 44 – 20mA DC × 2, Do × 1, Di × 11 – 5V DC × 2, Do × 1, Di × 14 – 20mA DC × 2, Do × 21 – 5V DC × 2, Do × 2Modbus, Do × 3Do × 4
•••••••••
M4 Screw Connection LT-UNIT Series
M3.5 Screw Connection L-UNIT Series
Plug-in K-UNIT Series
P.96
Construction Terminal access at the front Terminal access at the front Plug-in
Connection M4 screw terminal M3.5 screw terminal M3.5 screw terminal
Dielectric Strength 2000V AC 2000V AC 2000V AC
Auxiliary Power AC / DC AC / DC AC / DC
Self Powered Type Available Available Available
Operating Temperature -10 to +55°C (14 to 131°F)
-10 to +55°C (14 to 131°F)
-10 to +55°C (14 to 131°F)
Mounting Surface or DIN rail Surface or DIN rail Surface or DIN rail
Dimensions W39 [72] × H111 × D143 mm (1.54” [2.83] × 4.37” × 5.63”)
W75 × H80 × D112 mm (2.95” × 3.15” × 4.41”)
W50 [72] × H80 × D123 [132] mm (1.97” [5.20”] × 3.15” × 4.84” [2.83”])
IEC 60688 Yes – –
Standards & Approvals CE – –
LT-UNIT L-UNIT K-UNIT
n PT TransducerAverage – LPNA KP, KPNA
RMS LTPE LPE, LPNE KPE, KPNE2 channels, Average – L2PA, L2PNA –
2 channels, RMS – L2PE, L2PNE –3 channels – L3PK –
n CT TransducerClamp-on Current Sensor;
RMS sensing LTCEC – KCEC
Average – LCNA KC, KCNARMS LTCE, LTCNE LCE, LCNE KCE, KCNE
2 channels, Average – L2CA, L2CNA –2 channels, RMS – L2CE, L2CNE –
3 channels – L3CK –
n PT/CT TransducerAverage – LPCA –
RMS – LPCE –
n Watt / Var / Power Factor / Phase Angle / Frequency / Bidirectional Current Transducer
Watt LTWT, LTWTN LWT, LWTNKEWT, KEWTN,KUWT, KUWTN,KUWE, KUWEN
Var LTRP, LTRPN LRP, LRPN KERP, KERPN,KURE, KUREN
Power Factor LTPF, LTPFN LPF, LPFN KEPF, KEPFNPower Factor
(for unbalanced load) LTPFU, LTPFUN LPFU, LPFUN KEPFU, KEPFUN
Phase Angle(self-powered) LTPA, LTPAN LPA, LPAN KEPA, KEPAN
Phase Angle(for unbalanced load) LTPAU, LTPAUN LPAU, LPAUN KEPAU, KEPAUN
Frequency LTHZ, LTHZN LHZ, LHZN KEHZ, KEHZNBidirectional Current – LCY –
Phase Angle(between two voltages) – LPD –
n ZCT TransmitterZCT
(zero-phase current transformer) – – KCEZ
n Limit AlarmQuad DC Alarm – L4AS –
CLS Series
Clamp-on Current Sensor CLS Series
CLSA / CLSB / CLSC / CLSD / CLSE
P.107
D
110
Bargraph Indicators
Digital Panel Meters
6DV Series
43 Series
Four-wire Signal Conditioners
Two-wire Signal Conditioners
Power Transducers
Indicators
Limit Alarms
Gateway,Remote I/O
Paperless RecordingSystem
PC Recorder
Electronic Actuators& Position Sensors Lightning Surge Protectors
Indi
cato
rs
Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1
D
Bargraph Indicators
Digital Panel Meters
6DV Series
43 Series
Four-wire Signal Conditioners
Two-wire Signal Conditioners
Power Transducers
Indicators
Limit Alarms
Gateway,Remote I/O
Paperless RecordingSystem
PC Recorder
Electronic Actuators& Position Sensors
Lightning Surge Protectors
Indi
cato
rs
111Specifications are subject to change without notice.ISP1-1
Indicators Products Selection Guide
IndicatorsProduct Selection Guide
IndicatorsProduct Selection Guide
Bargraph Indicator 48NV
Bargraph Indicating Alarm Bargraph Indicating Alarmwith 4-digit digital meter
Bargraph Indicating Alarm(Sensor Input)
Bargraph Indicating Alarm with 4-digit digital meter
(Sensor Input)Bargraph Indicator
48SVBargraph Indicating Alarm
49AV2
P.114 P.114 P.114 P.114 P.114
Bargraph 101-segment LED 101-segment LED 101-segment LED 101-segment LED 101-segment LED 51-segment LED 51-segment LED
Scale Length 100 mm (3.96”) long,3.00 mm (.12”) wide
100 mm (3.96”) long,3.00 mm (.12”) wide
100 mm (3.96”) long,3.00 mm (.12”) wide
100 mm (3.96”) long,3.00 mm (.12”) wide
100 mm (3.96”) long,3.00 mm (.12”) wide 50 mm (1.97”) long 89 mm (3.50”) long,
angle 120°
Scale Custom Custom Custom Custom Custom 0 – 100% 0 – 100%
Bar Color Red, Amber, Green, Blue Red, Amber, Green, Blue, Multi-color
Red, Amber, Green, Blue, Multi-color
Red, Amber, Green, Blue, Multi-color
Red, Amber, Green, Blue, Multi-color Red Multi-color
(Red, Orange and Green)
Digital Meter – – 4 digits, Red LED – 4 digits, Red LED – 4 digits, Red LED
Connection M3 screw terminal M3 screw terminal M3 screw terminal M3 screw terminal M3 screw terminal Connector(leadwires soldered) M4 screw terminal
Direct Sensor Input – – – Yes Yes – –
Excitation Supply – Optional Optional – – – –
Alarm Output – 2 or 4 points 2 or 4 points 2 or 4 points 2 or 4 points – 2 or 4 points
Analog Output – Optional Optional – – – –
Power Input AC / DC AC / DC AC / DC AC / DC AC / DC DC AC / DC
Mounting Direction Vertical / Horizontal Vertical / Horizontal Vertical Vertical / Horizontal Vertical Vertical / Horizontal Vertical
Dimensions W36 × H144 × D103 mm(1.42” × 5.67” × 4.06”)
W36 × H144 × D103 mm(1.42” × 5.67” × 4.06”)
W36 × H144 × D103 mm (1.42” × 5.67” × 4.06”)
W36 × H144 × D103 mm(1.42” × 5.67” × 4.06”)
W36 × H144 × D103 mm(1.42” × 5.67” × 4.06”)
W18 × H72 × D118 mm (0.71” × 2.83” × 4.65”)
W96 × H96 × D116 mm (3.78” × 3.78” × 4.61”)
Degree of Protection IP65 front cover IP65 front cover IP65 front cover IP65 front cover IP65 front cover – –
Standards & Approvals CE CE CE CE CE – –
48NV 48NAVx 48NDVx 48NAx 48NDx 48SV 49AV2
n Bargraph IndicatorDC Input 48NV – – – – 48SV –
n Bargraph Indicating AlarmDC Input – 48NAV – – – – –
Transmitter Output – 48NAVA – – – – –2-wire Transmitter Excitation – 48NAVD – – – – –
Thermocouple Input – – – 48NAT – – –RTD Input – – – 48NAR – – –
Potentiometer Input – – – 48NAM – – –
n Bargraph Indicating Alarm (with 4-digit digital meter)DC Input – – 48NDV – – – 49AV2
Transmitter Output – – 48NDVA – – – –2-wire Transmitter Excitation – – 48NDVD – – – –
Thermocouple Input – – – – 48NDT – –RTD Input – – – – 48NDR – –
Potentiometer Input – – – – 48NDM – –
Indicators Products Selection Guide
D
112
Bargraph Indicators
Digital Panel Meters
6DV Series
43 Series
Four-wire Signal Conditioners
Two-wire Signal Conditioners
Power Transducers
Indicators
Limit Alarms
Gateway,Remote I/O
Paperless RecordingSystem
PC Recorder
Electronic Actuators& Position Sensors Lightning Surge Protectors
Indi
cato
rs
Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1
D
Bargraph Indicators
Digital Panel Meters
6DV Series
43 Series
Four-wire Signal Conditioners
Two-wire Signal Conditioners
Power Transducers
Indicators
Limit Alarms
Gateway,Remote I/O
Paperless RecordingSystem
PC Recorder
Electronic Actuators& Position Sensors
Lightning Surge Protectors
Indi
cato
rs
113Specifications are subject to change without notice.ISP1-1
Indicators Products Selection Guide
IndicatorsProduct Selection Guide
IndicatorsProduct Selection Guide
LCD Display 47D Series
LED Display 47L Series
46 Series
43DV1
Loop Powered 6DV/6DVI
Loop Powered 6DV-B/6DVI-B
Loop Powered 43AL
Loop Powered 43AL-B
P.122 P.123 P.132 P.130 P.130 P.132 P.132
Display 5 1/2 digitsRed / Green LCD
4 or 4 1/2 digits Red, Orange, Green, Bluegreen, Blue,
White LED(47LYV: Red/Orange only)
4 digitsRed / Green LED
3 1/2 digitsRed LED
4 digitsRed LED
4 digitsRed LED
3 1/2 digitsRed LED
3 1/2 digitsRed LED
Connection M3 screw terminal / Terminal block / 50-pin connector M3 screw terminal M3 screw terminal Connector
(leadwires soldered) Terminal block Terminal block Terminal block Terminal block
Scaling Yes Yes – Yes 4 – 20mA DC 4 – 20mA DC 4 – 20mA DC 4 – 20mA DC
Direct Sensor Input Yes Yes – – – – – –
Alarm Output Optional, 2 or 4 points Optional, 2 or 4 points Optional, 2 or 4 points – – – – –
BCD Output Optional – Optional – – – – –
Network Interface Optional, RS-485 / Modbus RTU – Optional – – – – –
Analog Output Optional Optional Optional – – – – –
Power Input AC / DC AC / DC AC / DC DC None None None None
Dimensions W96 × H48 × D98.5 mm(3.78” × 1.89” × 3.88”)
W96 × H48 × D98.5 mm(3.78” × 1.89” × 3.88”)
W102.5 × H48 × D104 mm(4.04” × 1.89” × 4.09”)
W48 × H24 × D72 mm(1.89” × 0.94” × 2.83”) 70 (2.76”) dia. 110 (4.33”) dia. W48 × H24 × D40 mm
(1.89” × 0.94” × 1.57”) 110 (4.33”) dia.
Degree of Protection IP66 front panel IP66 front panel – – – – – –
Standards & Approvals – CE – – CE / ATEX / FM CE / ATEX / FM CE / UL CE / ATEX / FM
47D Series 47L Series 46 Series 43DV1 6DV Series 6DV-B Series 43AL 43AL-B
DC Input (indicator only) – 47LYV 46DL2 43DV1 – – 43AL –
DC Input (indicator only / intrinsically safe) – – – – 6DV, 6DVI – – –
DC Input (indicator only / explosion-proof) – – – – – 6DV-B, 6DVI-B – 43AL-B
DC Input 47DV 47LV 46DV2 – – – – –Thermocouple Input 47DT 47LT – – – – – –
RTD Input 47DR 47LR – – – – – –Potentiometer Input 47DM 47LM – – – – – –
AC Input – 47LAC – – – – – –Strain Gauge Input – 47LLC – – – – – –
VT Input – 47LPT – – – – – –CT Input – 47LCT – – – – – –
Frequency Input – 47LPA, 47LHZ, 47LPQ – – – – – –
Indicators Products Selection Guide
E
136
Four-wire Signal Conditioners
Two-wire Signal Conditioners
Power Transducers
Indicators
Limit Alarms
Gateway,Remote I/O
Paperless RecordingSystem
PC Recorder
Electronic Actuators& Position Sensors Lightning Surge Protectors
Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1
Limit Alarms Product Selection Guide
Limit AlarmsProduct Selection Guide
EFour-wire Signal Conditioners
Two-wire Signal Conditioners
Power Transducers
Indicators
Limit Alarms
Gateway,Remote I/O
Paperless RecordingSystem
PC Recorder
Electronic Actuators& Position Sensors
Lightning Surge Protectors
137
Limit Alarms Product Selection Guide
Limit AlarmsProduct Selection Guide
Specifications are subject to change without notice.ISP1-1
Digital Adjustments AS4 Series
LCD Display M7E-UNIT Series
Extra DC Output AE-UNIT Series
Rotary Switch Adj. AL-UNIT Series
Potentiometer Adj. A-UNIT Series
M-PAC Series
Construction Plug-in Plug-in Plug-in Plug-in Plug-in Plug-inConnection M3.5 screw terminal M3 screw terminal M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal
Isolation Input to output to power Input to output to power Input to DC output to relay output to power Input to output to power Input to output to power Input to output to power
Dielectric Strength 2000V AC 2000V AC 2000V AC 2000V AC 2000V AC 1000V AC
Input Range Selectability Front key programming Front control buttons or PC software Specified when ordering Specified when ordering Specified when ordering Specified when ordering
No. of Alarm Point 2, 4 2, 4 2 2 2 1 or 2Relay Form Dual SPDT or Quad NO or NC Dual SPDT or Quad NO or NC SPDT SPDT SPDT SPDT or DPDT
Alarm Setting Front key programming Front control buttons or PC software Thumbwheel switches 10-position rotary switches 270°-turn screwdrivers Three-turn screwdrivers
Alarm Setpoint 0 – 100% 0 – 100% 0 – 99% 0 – 99% 0 – 100% 0 – 100%Deadband (Hysteresis) Adj. FS FS 9% – 1 – 100% 1 – 100%
Latching Output Yes Yes – – – YesSetpoint Accuracy ±0.1% FS ±0.1% FS ±0.5% ±0.5% ±0.5% ±0.2%
Alarm Test – Yes – – – –DC Output – – Yes – – Optional
Power Input AC / DC AC / DC AC / DC AC / DC AC / DC AC / DC
Operating Temperature -5 to +55°C (23 to 131°F)
-5 to +55°C (23 to 131°F)
-5 to +55°C (23 to 131°F)
-5 to +60°C (23 to 140°F)
-5 to +60°C (23 to 140°F)
-5 to +60°C (23 to 140°F)
Mounting Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface (DIN rail available for 11-pin base)
Dimensions W50 × H80 × D132 mm(1.97” × 3.15” × 5.20”)
W29.5 × H83 × D124 mm(1.16” × 3.27” × 4.88”)
W72 × H80 × D132 mm (2.83” × 3.15” × 5.20”)
W50 × H80 × D132 mm (1.97” × 3.15” × 5.20”)
W50 × H80 × D132 mm (1.97” × 3.15” × 5.20”)
W50 × H80 × D132 mm(1.97” × 3.15” × 5.20”)
W80 × H101 × D136 mm (3.15” × 3.98” × 5.35”)
Standards & Approvals CE / UL / C-UL CE – – – –
AS4 Series M7E-UNIT AE-UNIT AL-UNIT A-UNIT M-PAC
DC Input AS4V M7EASV AEV,AEAD (two-input addition) ALV ACV MP1000
Thermocouple Input AS4T – AET ALT ATC MP1200RTD Input AS4R – AER ALR ARB MP1400
Potentiometer Input AS4M – AEM ALM APOT MP1800Two-wire Transmitter – M7EASDY AEDY, AEDN ALDY, ALDN ADY, ADN MP1100Strain Gauge Input AS4LC – – – – –
AC Input – – AETG, AEAC ALTG, ALAC ATG, AAC MP1600PT Input – – AEPT ALPT APTA, APTE –CT Input AS4CT – AECT ALCT ACTA, ACTE –
Frequency Input – – AESP ALSP ASP MP1700Others – – – ALNR (Angle Sensor) ANR (Angle Sensor) –
Front View
L1
L2
L3
L4ALARM
DATA
ITEM
DATAITEM
ITEM No. Display
DATA UP-DOWN KeysITEM No. UP-DOWN Keys
MonitorLEDs
DATA Display
LCD Display
Mode ButtonSet ButtonPC ConfiguratorJack
Up ButtonDown Button Up
Down
Mode
Set
Hysteresis (Deadband)Adj. Thumbwheel SW
Setpoint Adj.Thumbwheel SW
Monitor LED
Monitor LEDHysteresis (Deadband)Adj. Thumbwheel SW
• OUTPUT 2
• OUTPUT 1
Setpoint Adj.Thumbwheel SW
9 99
9 99
Span Adj.Zero Adj.
No.1 SetpointRotary SW (x10%)No.1 SetpointRotary SW (x1%)No.2 SetpointRotary SW (x10%)No.2 SetpointRotary SW (x1%)
No.1 LED
No.2 LED
No.1 LED
No.1 Hysteresis (Deadband) Adj.No.2 Hysteresis (Deadband) Adj.
No.2 LED
No.1 Setpoint Adj.
No.2 Setpoint Adj.
Zero Adj.
Span Adj.No.1 LED
No.1 Hysteresis (Deadband) Adj.No.2 Hysteresis (Deadband) Adj.
No.2 LED
No.1 Setpoint Adj.
No.2 Setpoint Adj.
Zero Adj.
Span Adj.
E
138
Four-wire Signal Conditioners
Two-wire Signal Conditioners
Power Transducers
Indicators
Limit Alarms
Gateway,Remote I/O
Paperless RecordingSystem
PC Recorder
Electronic Actuators& Position Sensors Lightning Surge Protectors
Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1
Limit Alarms Product Selection Guide
Limit AlarmsProduct Selection Guide
EFour-wire Signal Conditioners
Two-wire Signal Conditioners
Power Transducers
Indicators
Limit Alarms
Gateway,Remote I/O
Paperless RecordingSystem
PC Recorder
Electronic Actuators& Position Sensors
Lightning Surge Protectors
139
Limit Alarms Product Selection Guide
Limit AlarmsProduct Selection Guide
Specifications are subject to change without notice.ISP1-1
n Digital Adjustments n Dial/Potentiometer Adjustments n Thumbwheel Switch Adjustments
MSEF M6SXAS, M6NXAS, M6DXAS KSE L4AS ASD1 KSED
Construction Plug-in Ultra-slim Plug-in Discrete box; terminal access at the front Plug-in Plug-in
Connection M3.5 screw terminal Tension-clamp, M3 screw terminal, Euro terminal M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal M3.5 screw terminalIsolation Input to output to power Input to output to power Input to output to power Input to output to power Input to output to power Input to output to power
Dielectric Strength 2000V AC 2000V AC 2000V AC 2000V AC 2000V AC 2000V ACInput Type DC input DC input DC input DC input DC input DC input
Input Range Selectability Front control buttons Specified when ordering or PC programming Specified when ordering Specified when ordering Specified when ordering Specified when ordering
No. of Alarm Point 2 1 1, 2 2, 4 2 2Relay Form SPDT SPDT SPDT SPDT SPDT SPDT
Alarm Setting Front control buttons PC software Dials Single-turn screwdrivers or dials Thumbwheel switches Thumbwheel switchesAlarm Setpoint -14 to +113.5% -2 to +102% -15 to +120% -15 to +115% 0 – 99% 0 – 99%
Deadband (Hysteresis) Adj. 0.5 – 15% 0 – 99.9999% – – 14% –Latching Output Yes – – – Yes –
Setpoint Accuracy ±0.5% ±0.05% FS ±0.3% ±0.3% ±0.5% ±0.5%Alarm Test – Yes – – – –DC Output – – – – – –
Power Input AC / DC DC AC AC / DC AC AC
Operating Temperature -5 to +55°C (23 to 131°F)
-20 to +55°C (-4 to +131°F)
-5 to +55°C (23 to 131°F)
-5 to +55°C (23 to 131°F)
-5 to +60°C (23 to 140°F)
-5 to +55°C (23 to 131°F)
Mounting Surface or DIN rail DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail
Dimensions W50 × H80 × D136 mm (1.97” × 3.15” × 5.35”)
M6D/S: W5.9 × H94 × D102 mm (0.23” × 3.70” × 4.02”)
M6N: W7.5 × H102 × D102 mm (0.30” × 4.02” × 4.02”)
KSE-x1: W50 × H80 × D136 mm (1.97” × 3.15” × 5.35”) KSE-x2: W50 × H80 × D145 mm (1.97” × 3.15” × 5.71”)
W75 × H80 × D112 mm (2.95” × 3.15” × 4.41”)
D126 mm (4.96”) with dial adjustments
W50 × H80 × D132 mm (1.97” × 3.15” × 5.20”)
W50 × H80 × D132 mm(1.97” × 3.15” × 5.20”)
Standards & Approvals CE / UL / C-UL CE CE – CE / UL / C-UL CE / UL / C-UL
Front View
Monitor LED•Output 1
Setpoint Adj.9 9
Setpoint Adj.•Output 2
9 9
Monitor LED
Deadband & Latching Control
Deadband & Latching Control
Hi Monitor LED
Hi Setpoint Adj.
Lo Setpoint Adj.
Lo Monitor LED
9 9
9 9
MODE Selector
Digital Display
DOWN ControlUP Control
L1 MonitorLED
L2 MonitorLED Status Indicator LED
Alarm Monitor LED
Configurator Jack
Power LEDHi Monitor LED
Hi Setpoint Adj. Dial
100
50 %
0
■ KSE-x1
Lo Monitor LED
Hi Setpoint Adj. Dial
Lo Setpoint Adj. Dial
Hi Monitor LED
100
50 %
SET1
0100
50 %
SET20
■ KSE-x2
1 2 3 4
Monitor LED
Setpoint Adj.
■ Dial Adjustments
1 2 3 4
Monitor LED
Setpoint Adj.
■ Screwdriver Adjustments
1 2 3 4
Monitor LED
Setpoint Adj.
■ Dial Adjustments
1 2 3 4
Monitor LED
Setpoint Adj.
■ Screwdriver Adjustments
E
140
Four-wire Signal Conditioners
Two-wire Signal Conditioners
Power Transducers
Indicators
Limit Alarms
Gateway,Remote I/O
Paperless RecordingSystem
PC Recorder
Electronic Actuators& Position Sensors Lightning Surge Protectors
Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1
Limit Alarms Product Selection Guide
Limit AlarmsProduct Selection Guide
n Thumbwheel Switch Adjustments n Deviation Alarm
M2SED M2AS M2AS1 AYDV
Construction Plug-in Plug-in Plug-in Plug-inConnection M3 screw terminal M3 screw terminal M3 screw terminal M3.5 screw terminal
Isolation Input to output to power Input to output to power Input to output to power Input to output to powerDielectric Strength 2000V AC 2000V AC 2000V AC 2000V AC
Input Type DC input DC input DC input DC inputInput Range Selectability Specified when ordering Specified when ordering Specified when ordering Specified when ordering
No. of Alarm Point 2 1 1 2Relay Form SPDT DPDT SPDT SPDT
Alarm Setting Thumbwheel switches Thumbwheel switches Thumbwheel switches Multi-turn screwdriversAlarm Setpoint 0 – 99% 0 – 99% 0 – 99% -50 to +50%
Deadband (Hysteresis) Adj. – FS FS –Latching Output – Yes Yes –
Setpoint Accuracy ±0.5% ±0.5% ±0.5% ±0.5%Alarm Test – – – –DC Output – – – –
Power Input AC / DC AC / DC AC / DC AC / DC
Operating Temperature -5 to +55°C (23 to 131°F)
-5 to +55°C (23 to 131°F)
-5 to +55°C (23 to 131°F)
-5 to +60°C (23 to 140°F)
Mounting Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail
Dimensions W29.5 × H76 × D124 mm (1.16” × 2.99” × 4.88”)
W29.5 × H76 × D124 mm (1.16” × 2.99” × 4.88”)
W23 × H76 × D124 mm (0.91” × 2.99” × 4.88”)
W50 × H80 × D132 mm (1.97” × 3.15” × 5.20”)
Standards & Approvals CE / UL / C-UL CE CE –
Front View Setpoint 1 Adj. & LED
Setpoint 2 Adj. & LED
Setpoint 2 Monitor
Setpoint 1 Monitor
COM.
Output 1 Setpoint Adj.
Output 2 Setpoint Adj.
Output 1 Monitor LED
Output 2 Monitor LED
9 9
9 9
OutputSetpoint Adj.
Deadband Adj.
OutputMonitor LED
Reset Control
9 9
9 9
OutputSetpoint Adj.
Deadband Adj.
OutputMonitor LED
Reset Control
9 9
9 9