Practical,Code-CompliantDetailingforMid-RiseWoodStructuresDetailingConsiderationsforMidRiseWoodFrameBuildings

“TheWoodProductsCouncil”isaRegisteredProviderwithTheAmericanInstituteofArchitectsContinuingEducationSystems(AIA/CES),Provider#G516.

Credit(s)earnedoncompletionofthiscoursewillbereportedtoAIACESforAIAmembers.CertificatesofCompletionforbothAIAmembersandnon-AIAmembersareavailableuponrequest.

ThiscourseisregisteredwithAIACESforcontinuingprofessionaleducation.Assuch,itdoesnotincludecontentthatmaybedeemedorconstruedtobeanapprovalorendorsementbytheAIAofanymaterialofconstructionoranymethodormannerofhandling,using,distributing,ordealinginanymaterialorproduct.________________________________Questionsrelatedtospecificmaterials,methods,andserviceswillbeaddressedattheconclusionofthispresentation.

CourseDescription

Withanincreaseinmid-risewood-framebuildings,moredesignersareseekinginformationoncode-compliantandconstructibledetailing.Manyareunsureofthecode’srequirementsfordetails,specificallyattheintersectionofratedassembliesandwherestructureandfireprotectionmeet.Thispresentationwillfocusoncommondetailingissuesandareasofmisunderstanding—includingfire-resistanceratingcontinuity,allowableusesofwoodframinginshaftandfirewalls,andfiresafetyprinciplesassociatedwiththeintersectionoftworatedassemblies.Mid-risewood-frameopportunitiesandcode-specifiedbuildingsizeswillalsobereviewed,followedbydiscussionofdetailingcoderequirements,codecompliance,andrationaleforapprovalwithanemphasisonconstructabilityandpracticality.

LearningObjectives

1. Discussallowableconstructiontypes,occupancies,andbuildingheightsandareasforwood-framemid-riseconstructionpertheInternationalBuildingCode.

2. Examineavarietyoffloor-to-exteriorwalldetailsforuseinwood-frame,TypeIIIconstructionanddiscusscodecompliancepathsandapprovalrationaleforeach.

3. Discusscode-permittedshaftwallandfirewallconstructionmaterialsandfire-resistancerequirements,andreviewcommondetailsforeach.

4. Considercodeprovisionsforcorridorandbalconyfire-resistanceprotection,andidentifydetailsthataccommodatetheserequirementswhilemaximizingwooduse.

Outline

• Mid-RiseConstructionTypes&LifeSafetyReview• StructuralDesign&DetailingConsiderations• ShrinkageConsiderations&Detailing• AcousticRequirements&Detailing• FireResistiveRequirementsandDetailing

Mid-RiseConstructionTypes

Materials ProtectedElements

LessProtectedElements

UnprotectedElements

Non-Combustible IA,IIA IB IIB

Combustible - - -

Mixed Systems IIIA IIIB -

HeavyTimber - IV -

AnyMaterials VA - VB

ICCBuildingValuationData

80

90

100

110

120

130

140

150

160

IA IB IIA IIB IIIA IIIB VA VB

$pe

rSqu

areF

oot

IBCConstruction Type

InternationalCodeCouncil,August2015DataR-2Occupancy

PrimaryStructuralWoodFramingAllowed

IBCBuildingSizeLimits

Construction TypeAllowableLimit

IIIA IIIB VA VB

Stories 4 4 3 2Height(ft) 65 55 50 40BuildingArea/Story(ft2) 24k 16k 12k 7kTotalBuildingArea*(ft2) 72k 48k 36k 14k

IBC2012Table503TabularValues

Residential(R1,R2,andR4)Occupancies

*Assumingmaxstoriesbuilt

IBCBuildingSizeLimits

WithNFPA13Sprinklers:IBCgivesanallowableHeightsandAreaIncrease

IIIATabularHeightLimits IncreasedLimits

NFPA13

IBCBuildingSizeLimitswithSprinkler

TypeIIIAConstructionAllowableLimit

Table503

Stories 4Height(ft) 65BuildingArea/Story(ft2) 24kTotalBuildingArea*(ft2) 72k

Residential(R1,R2,andR4)Occupancies

*AssumingmaxstoriesbuiltperIBC506.4

503

NPFA13

58524k72k

504.2IBC2012Section

NPFA13

58572k216k506.3

Frontage**

58590k270k506.2

**Maximumfrontageincreasepossible

StellaApartmentsLocation:MarinaDelRay,CA244Apts.,650Ksf total(2bldgs)TypeIIIAandVAconstructionPanelizedwoodframingsaved1-2monthsconstructiontimeand$200,000

CaseStudy:StellaApartments

Architect:DesignARC.LosAngeles,CAPhotos:LawrenceAnderson,www.lawrenceanderson.net

Outline

• Mid-RiseConstructionTypes&LifeSafetyReview• StructuralDesign&DetailingConsiderations• ShrinkageConsiderations&Detailing• AcousticRequirements&Detailing• FireResistiveRequirementsandDetailing

Structural• Directbearing/noadd’l

hardware• Mayrequireloadtransfer

blockingforconcentratedloadsfromabove

• Wallsoleplateandfloorsheathingcrushingmayneedtobeconsidered

Constructability• Framingcanbecompletedbefore

drywallandinsulationareinstalled

• Commonlengthstuds

PlatformFraming

Semi-balloonFraming

Structural• Additionalhardware/nodirect

bearing• Noloadtransferblockingreq’dRatedAssemblies• Mayaccommodatecontinuity

inexteriorwallsinTypeIIIconstruction

Constructability• Framingcanbecompleted

beforedrywallandinsulationareinstalled

• Customlengthstuds• Canhelpminimizebuilding

shrinkage

ShearWallFramingConsiderations

TypicalFloorPlanShearWallLayoutIndicateswoodsheathedshearwall

ShearWallFramingConsiderations

• Typicalfloorplanresultsinshortersolidwallsections,offsetwalls,needformorecollectors,struts

• Shorterwalls=higherconcentratedloads• Higherconcentratedloads=tighternailing,largerholddowns&

endposts,possiblydoublesidedsheathing• Coderequirementsforwallheighttowidthratiosmustbemet• Accumulatedloadsfurtherconcentrateforcesinlowerlevel

walls

ShearWallFramingConsiderations

• Shearwallcomponentscanaffectotherbuildingfeatures

• EndPosts:Morewoodinwall=lessinsulation

• Sheathingoninteriorwallsaffectwallfinishes,acoustics

• Holddowns,endposts,blockingcanaffectin-wallutilities

• OpeningsinwallsforMEPcanaffectshearwallstrength

ShearWallConfigurationOptions

SolidorSegmentedWalls

PerforatedWallsForceTransferAround

OpeningsWalls

ShearWallHoldDownOptions

StandardHoldDownInstallation StrapHoldDown

Installation

……

……

……

Continuous Rod - Automatic Tensioning Systems

DiaphragmConsiderations

TypicalFloorPlanDiaphragmLayout

Open

DiaphragmConsiderations

• Typicalfloorplanresultsindiaphragmoffsets,re-entrantcorners,discontinuities,openings

• Diaphragmopenings,discontinuities=higherconcentrated,localizedloads

• Higherconcentratedloads=tighternailing,largerchord&strutloads,mayrequireblockeddiaphragm

• Coderequirementsfordiaphragmlengthtowidthratiosmustbemet

ShearWalltoPodiumSlabInterface

• AmplificationofseismicforcesisrequiredforelementssupportingdiscontinuouswallsperASCE7-1012.3.3.3

• Overstrength factorof3(maybereducedto2.5perfootnotegofTable12.2-1)isrequired

• AttachmenttoconcreteslabmustalsoconformtoACI318AppendixD

• TypicallywillbetransitioningfromASDforwooddesigntoLRFDforconcretedesign

• Holddownattachmentstoconcreteoptions:embeddednutsorplates,sleevesthroughslab,weldedstuds&reinforcing

PTSolePlatevs FRTContinuity

IntypeIIIconstructionwithFRTstuds,whathappenswherethesoleplateisincontactwithconcrete?

• FRTWisrequired• PTwoodisrequiredFRTcontainsabout10xboratecompoundfoundinPT(borateiswatersoluble)Canspecifyaproducttestedtodoboth

Outline

• Mid-RiseConstructionTypes&LifeSafetyReview• StructuralDesign&DetailingConsiderations• ShrinkageConsiderations&Detailing• Concepts• Calculations• Recommendations

• AcousticRequirements&Detailing• FireResistiveRequirementsandDetailing

IBC2012onShrinkage2304.3.3Shrinkage.Woodwallsandbearingpartitionsshallnotsupportmorethantwofloorsandaroofunlessananalysissatisfactorytothebuildingofficialshowsthatshrinkageofthewoodframingwillnothaveadverseeffectsonthestructureoranyplumbing,electricalormechanicalsystems,orotherequipmentinstalledthereinduetoexcessiveshrinkageordifferentialmovementscausedbyshrinkage.Theanalysisshallalsoshowthattheroofdrainagesystemandtheforegoingsystemsorequipmentwillnotbeadverselyaffectedor,asanalternative,suchsystemsshallbedesignedtoaccommodatethedifferentialshrinkageormovements.

KeyFactorsInfluencingShrinkage

• Pre-constructionmoisturecontent(MC)• In-serviceequilibriummoisturecontent(EMC)• Cumulativethicknessofcross-grainwood

contributingtoshrinkage

Woodspecieshasrelativelylittleimpactsincemostspeciesusedincommercialconstructionhavesimilarshrinkageproperties.

Moisturechangescausedimensionalchangesperpendiculartograin

Growingtreeisfilledwithwater

Aswooddries,itshrinksperp.tograin

BasicWoodShrinkageTheory

Image:WoodHandbook,WoodasanEngineeringMaterial,USDAForestService,ForestProductsLaboratory,2010

Wider&Thicker--- NOTTaller

ShrinkageinlumberexpectedACROSSthegrain.Longitudinalshrinkageisnegligible.

BasicWoodShrinkageTheory

BasicWoodShrinkageTheory

ZoneofMovementShrinkageoccursprimarilyinhorizontalmembers• Wallplates• Floor/rimjoists

Beawareofcumulativeshrinkage.

Pre-ConstructionMoistureContent

Mi=19%Mi=28%

MinimizeConstructionMoistureAccumulation

1. Minimizestorageofmaterialonsitewhererainandstandingwatercanincreasemoisturecontent.

2. Keepunusedframingmaterialcovered3. Inspectpre-builtwallpanelspriortoinstallationforproper

materialandqualityofmechanicalfasteners.4. “Dry-in”thestructureasquicklyaspossible.5. Immediatelyremoveanystandingwaterfromfloorframing

afterrainshowers.6. EnsurethatinstalledlumberMCisloweredto19%or

calculatedmaxMCbeforeinstallingfinishes&insulation

In-serviceAverageEMCinJuly

34

Map courtesy of US Forest Products Laboratory

In-serviceAverageEMCinJanuary

35

Map courtesy of US Forest Products Laboratory

ComprehensiveShrinkageEstimation

ForachangeinMCbetween 6%and14%theshrinkageformulais:

( )[ ]iFTi MMCDS −=

CalculatingShrinkage

S=shrinkage(ininches)

Di =initialdimension(ininches)

CT /CR=dimensionchangecoefficient,tangential/radialdirection

CT =0.00319forDouglasFir-LarchCT =0.00323forHem-FirCT =0.00263forSpruce-Pine-FirCT =0.00263forSouthernPine

MF =finalmoisturecontent(percent)

Mi =initialmoisturecontent(percent)

ComprehensiveShrinkageEstimation

ForMCoutside therangeof6to14%:

( )

iT

iFi

MS

MMDS

+−

−=

30)100(30

CalculatingShrinkage

S=shrinkage(ininches)

Di =initialdimension(ininches)

ST /SR=tangential/radialshrinkage(%)fromgreentoovendry

MF =finalmoisturecontent(percent)

Mi =initialmoisturecontent(percent)

CalculatingShrinkage– Resources

WoodHandbook:www.fpl.fs.fed.us• Chapter13– CT,CR• Chapter4– ST,SR

ExampleShrinkageCalculation

Assume:S-DrylumberFind:ShrinkageinPlates&FloorJoist

ShrinkageZone:2x4UpperPlate2x12FloorJoist4x4LowerPlate16.25”Total

QuickShrinkageEstimation:

AgainassumingtheinitialMC(Mi)is19percentandthefinalMC(MF)is12percent

Ourapproximatedshrinkageis:

ForDougFirLarch:

ForS-P-ForSouthernPine:

S =CDi MF −Mi( ) = 0.00319×16.25 12−19( ) = −0.36inch

ExampleShrinkageCalculation

S =CDi MF −Mi( ) = 0.00263×16.25 12−19( ) = −0.3inch

MinimizingShrinkage

Semi-balloonframing• incorporatesfloorframing

hangingfromtopplates• Eliminatestangential

shrinkageinzoneofmovement

• Floorframingdoesn’tcontributetooverallbuildingshrinkage

Non-standardstudlengthsandincreasedhardwarerequirementsarearesult.

ExampleShrinkageCalculationAssume:S-DrylumberFind:Shrinkagein2x4UpperPlate&4x4LowerPlate

ShrinkageZone:2x4UpperPlate4x4LowerPlate5”Total

QuickShrinkageEstimation:

AgainassumingtheinitialMC(Mi)is19percentandthefinalMC(MF)is12percent

Ourapproximatedshrinkageis:ForDougFirLarch:

ForSouthernPine:

S =CDi MF −Mi( ) = 0.00319×5 12−19( ) = −0.11inch

ExampleShrinkageCalculation

S =CDi MF −Mi( ) = 0.00263×5 12−19( ) = −0.09inch

DifferentialMovement

Movementbetweenwoodframeelementsandothermaterialsthat…

• donotshrinkatall

• shrinkmuchless

• expand

Shrinkage&FinishConsiderations

Largeexpansesofinteriorandexteriordrywall,panelingandsidingneedtobelookedatspecifically.

Employexpansionjointandslip-typedetailing.

Attentiontointeractionofstructural(load-bearing)andnon-structuralelementsisnecessary

Shrinkage&MEPConsiderations

FullycompresswallframingbycompletingalldeadloadpotentialPRIORtomechanicalinstallations.

Avoidrigidverticalpipinginmechanicalandplumbingsystems.Flexiblemembersallowforshrinkagebetweenfloors.

MEPConsiderations

Verticalventstacksshouldbeinstalledaftercompletionofframing.

Ventstacksrequirespecialattentionandmustbedesignedtoallowforverticalmovementduetoshrinkagebetweenfloors.

MEPJointOptions

AvarietyofexpansionorslipjointconnectorsareavailablewhichaddressthisissueandallowverticalmovementinMEPitemsduetobuildingshrinkageand/orthermalchangewithoutcausingdamagetothem

BrickFaçade:Solution1- PlainUnreinforcedBrick-h>30’

Allowsforverticalshrinkageofwoodframing

VeneermustbedesignedperACI530section2.2asplainunreinforcedmasonry

Anchors/tiestobespacedamaximumof32”o.c.horiz.And18”o.c.vert.(exceptseismic)

Requiressteellintelatopenings

Jointsmustallowforalldifferentialmovement(lateraldriftandvertical shrinkageofwoodFramingEtc.).WeightofbrickmustnotbesupportedbywoodFraming

Woodbackerstuds

Brickgoesintoflexurewhenwallstudsdeflect

DesignmustbeinstrictconformancewithACI530section6.2.1-Alt.designmethod(engineered)

Designtosection2.2(ASD)or3.2.2(strength)unreinforcedmasonry

Brickveneermustbeselfsupportingandnotsupportedoffofthewoodframing

BrickFaçade:Solution2- StructuralReinforcedBrick

BrickunitsaresimilartoCMU’swhereverticalandhorizontalreinforcingcanbeinstalled• Veneerspansfloortofloor

withouttransferringloadstowalls.

• Loadsaredumpeddirectlyintofloordiaphragms

• Steellintelsoveropeningsarenotrequired

• Intermediateanchors/tiesarenotrequired

• Wallspansvert.&horiz.Betweenspacedanchors

Reinf.horizontalbondbeamorlintelunitsoveropenings

Spacedanchorsmustallowforalldifferentialmovement(lateraldrift,vertical shrinkageofwoodFraming,etc.).WeightofbrickmustnotbesupportedbywoodFraming

Woodbackerstuds

Reinforcementreducesexpansionandcracking

Anchors/tiesaretieddirectly intofloordiaphragms

Veneeractsascompleteunit,notasindividualSegments.Supportsselfweightplusout-of-planeloads

#3or#4rebar (typ.)

Heavieranchorsarenotaspronetofiredamage

4”nom.orgreater

FaçadeConsiderations- Resourceswww.woodworks.org

FaçadeConsiderations- Resources

BrickIndustryAssociation–www.gobrick.com

DoorandWindowConsiderations

Sealantjointsizedtoallowshrinkageofwoodframeandexpansionofbrick(typically¼”to½”perfloor)

DoorandWindowConsiderations

FlashingandCounterFlashingDetailedtoProvideVerticalFlashingSlipJointtoAccommodateMovement

Source:FPInnovations

DoorandWindowConsiderations

Gapunderflashingallowsverticalmovement

Source:CENews,Feb2014

DoorandWindowConsiderations

Source:CENews,Feb2014

ShrinkageEffectsonStructuralComponents

Strapholddownscanbucklewithtoomuchaccumulatedmovement.

Anchortypeholdownsshouldre-tightenedbeforeinstallingfinishes.

Threadedrodholdownswithshrinkagecompensatingdevicesworkwellfor4storiesandabovewithstackingunits.

Shrinkage&DeckConsiderations

WhitePaper:Multi-StoryWood-FrameShrinkageEffectsonExteriorDeckDrainage:ACaseStudybyZenoMartin,WoodDesignFocusFall2010

ShrinkageMitigatingDetailingTips

Bestpracticestomitigatedistresstofinishesarisingfromcumulativedifferentialmovement:• Beacutelyawareofthefactthattherewillbedifferentialmovement• Addressitindetailingandspecifications• Considerwheredistresswilloccur• Providedetailstorelieveoravoidit

Architects:CooperCarry&ThePrestonPartnershipPhoto:AerialPhotographyInc.

ShrinkageResources– www.wwpa.com

Outline

• Mid-RiseConstructionTypes&LifeSafetyReview• StructuralDesign&DetailingConsiderations• ShrinkageConsiderations&Detailing• AcousticRequirements&Detailing• FireResistiveRequirementsandDetailing

BuildingAcousticsOverview

Air-bornesound:• SoundTransmissionClass

(STC)Measureshoweffectivelyanassemblyisolatesair-bornesoundandreducesthelevelthatpassesfromonesidetotheother

Structure-bornesound:• ImpactInsulationClass

(IIC)Evaluateshoweffectivelyanassemblyblocksimpactsoundfrompassingthroughit

AcousticalCodeRequirements

IBCSection1207:

Min.STCof50(45iffieldtested)for:• AllWalls,Partitions,andFloor/CeilingAssemblies

whichseparateadjacentdwellingunitsoradwellingunitfromanadjacentpublicarea

Min.IICof50(45iffieldtested)for:• AllFloor/CeilingAssemblieswhichseparate

adjacentdwellingunitsoradwellingunitfromanadjacentpublicarea

AcousticalIsolationBetweenUnits

ClassDesignation Airborne SoundIsolation(STC)

FloorCeilingImpactIsolation(IIC)

EntryLevel 50 50

MarketRate 55 55

Luxury 60 60

Exterior-to-Unit

SingleFamily

LandUseCategory ExteriorDay/NightNoiseLevels(Ldn,dBA)

MultiFamily

Motel,Hotels

OutsideUse

55 60 65 70 75 80

NormallyAcceptable

Conditionally Acceptable

NormallyUnacceptable

ClearlyUnacceptable

StateofCaliforniaGeneralPlanGuidelines,1987

Retail-to-Unit

TypicalFloor-CeilingDetailAlthoughcommonbetweenrestaurantsorbarsandtheapartments above,theconfigurationshowninthisdetailmayleadtonoisecomplaints byapartmentoccupants.

RatedAssemblies

OneofManyPerformanceGoals

UniversityofWashingtonStudentHousingSeattle,WAArchitect:MahlumThisfive-building projectincludes astrategiccombination ofstaggeredanddouble studwallstominimizesoundtransmission. Photo:BenjaminBenschneider

AcousticallyRatedAssemblies

ManyavailablefreeonlineSTC&IICratedassemblycharts(USG,GP,others)

AcousticallyRatedAssemblies

AirTightandInsulated

Examplesofineffectiveandeffectiveinstallation

PhotoDr.EnergySaver

ElectricalBoxes– AvoidFlankingPaths

Walls– DoubleStud

STC63PartyWallImage:tmsoundproofing.com

Walls– StaggeredandSingleStud

Afterdoublestudconstruction,thenextbestsolutionsarestaggeredandsinglestud.

Photos:RootGraphics(l);ArchWoodProtection

AcousticalDetailing

ImprovementFactor:Sheathing

Effectofsheathing placement onacoustical performance

ImprovementFactor:Insulation

Themostcost-effectiveacousticalimprovementtoasoundinsulationsystemistheadditionofbattinsulationoranyopencellfoamsystemtothestudorjointcavity.

PhotoDreamstime

ImprovementFactor:ResilientChannels

Metalchannelsfoundinwoodframing

Acoustical‘puckisolator’walldetail(isometricview)

ImprovementFactor:ResilientChannels

Properresilientchannelandfastenerinstallationiskeytotheperformanceofthesystem

Floor-CeilingSystems

AcousticalDetailing

Effectivefloor-ceilingoptionincludes:• Gypcreteorlight-weightconcrete• Impact isolationmatt• Tongueandgroovesubfloor(gluedandscrewedtothe joist)• Joistsystem(with6inchesofbattinsulation)• Resilient channelorpucksystem(resilient system)• Twolayersof5/8-inchtype“X”gypsumboard

ImpactIsolation

Impact IsolationProgression inWood-FrameFloors/Ceilings (SectionView)

Forclarity,battinsulationinthejoistcavityisnotshown

AdditionalAcousticsBestPractices

• Avoidcreatingflankingpaths• Isolatemechanicalsystemsbetweenunits• Sealopeningsinassemblies(whereairflows,sound

flows)• Avoidaligningdoorsonoppositesidesofcommon

hallways

Doorways– AvoidFlankingPaths

Avoidaligningdoorsonoppositesidesofcommonhallways

HVAC– AvoidFlankingPaths

Isolatemechanicalsystemsbetweenunits

AdditionalConsiderations

CrescentTerminusAtlanta,GAThree-building, five-storymixed-usecomplexwithresort-style amenities

PhotoCrescentCommunities

Outline

• Mid-RiseConstructionTypes&LifeSafetyReview• StructuralDesign&DetailingConsiderations• ShrinkageConsiderations&Detailing• AcousticRequirements&Detailing• FireResistiveRequirementsandDetailing

• ExteriorWalls• FloortoWallDetailing• InteriorWalls• ShaftWalls• Corridors&Balconies

Key Differences in Fire Ratings for Construction Types

IIIA IIIB VA

Exterior (bearing) wall framing FRT FRT non-FRT

Exterior wall fire rating 2 hr 2 hr 1 hr

Interior bearing wall fire rating 1 hr 0 hr 1 hr

Interior non-bearing wall fire rating 0 hr 0 hr 0 hr

Floor assembly fire rating 1 hr 0 hr 1 hr

Fire wall rating 3 hr 3 hr 2 hr

FireResistanceRatings

IBCTables601&706.4Note:FRT=FireRetardantTreated

FirePerformanceCo

mbu

stibility FireResistance

FlameSpreadClassificaiton

Fire-ResistanceRatedWallAssemblies

FireConfinement StructuralPerformance

Fire-ResistanceRating:Theperiodoftimeabuildingelement,componentorassemblymaintainstheabilitytoconfineafire,continuestoperformagivenstructuralfunction,orboth,asdeterminedbythetests,orthemethodsbasedontests,prescribedinSection703.Tested underastandardizedtestfireexposureforagivendurationto:

1. Preventthepassage offlameandtemperature risefromonesidetotheother

2. Continue toprovideverticalstructuralsupportwhenexposed tofireandelevatedtemperatures

Fire-ResistanceRatedWallAssemblies

There arefive basictypesoffire-resistanceratedwallassemblies:• LightFrameBearingWalls(IBC704.4.1)• ExteriorWalls(IBC705)

• FireWallorPartyWall(IBC706)• FireBarrier(IBC707)• FirePartition(IBC708)

LightFrameBearingWalls(IBC704.4.1)

Kingstuds,jackstuds,andboundaryelementsmayhavefire-resistanceratingprovidedbymembraneinloadbearingwall

Typ.BearingWallOpeningFraming

ExteriorWalls- FSD

Basicassumptionisthatfiresbeginattheinteriorandratedwallassembliesarenotrequiredfrom theexteriorunlessclosetoanotherstructure.

Interior

Exterior

FireProtectiononInsideofBuilding

ExteriorWalls(IBC705)705.5 FireResistanceRatings:Exteriorwallsshallbefire-resistanceratedinaccordancewithTables601and602andthissection.Therequiredfire-resistanceratingofexteriorwallswithafireseparationdistanceofgreaterthan10feet(3048mm)shallberatedforexposuretofirefromtheinside.Therequiredfire-resistanceratingofexteriorwallswithafireseparationdistanceoflessthanorequalto10feet(3048mm)shallberatedforexposuretofirefrombothsides.

Interior

Exterior

X<10’

LotLine

Table 601&602

ExteriorWallFireResistance

ExteriorWall– Bearingvs.NonBearing

Nonloading-bearingexteriorwallsmayhavelowerfireresistanceratingrequirementsthanbearingwallsincertainsituations.IBCChapter2definesloadbearingwallsas:

ExteriorWallFireRatings

• Usingtheprovisionsofsection705.5andTables601and602couldresultinrequiringa1houror2hourratingontheinsidefaceofexteriorwalls,whilenoratingisrequiredontheexteriorfaceofexteriorwalls.

• Howdowespecifysuchanasymmetricassembly?

• Thisiswhereprescriptivecodemethodologybeginstobreakdown:proceduraldatadoesnotalignwithrequirements.Mostbuildingjurisdictionsunderstandthatthisisadeficiencyofthesystemandwillrecognizeonetestedassemblyfortheoutsideandasecondfortheinside.

2"HOUR EXTERIOR WALL

FRAMING AT 16" O.C.. MIN. 2 X 4

1 LAYER 5/8" FIBERGLASS MAT GYPSUM SHEATHING

STRUCTURAL WOOD PANEL(S)

WHERE REQUIRED FOR SHEAR

2"HOUR RATING PER UL DESIGN NO. U371

EXTERIOR CEMENT PLASTER, MIN. THICKNESS

3/4" TO FACE OF LATH

MIN. 3" THICK MINERAL

WOOL BATT INSULATION

2 LAYERS 5/8" TYPE 'X' GYPSUM

BOARD AT INTERIOR CONDITIONS

EXTERIOR CEMENT PLASTER OVER FIBERGLASS MAT GYPSUM

SHEATHING AT EXTERIOR CONDITIONS

ExteriorWalls- Asymmetry

Commonissueswithtestedassemblies:

• AssemblyAsymmetry-separateassembliesforeachside

ExteriorWalls– 1HRInt.0HRExt.

ExteriorWalls– 1HRInt.0HRExt.

ExteriorWalls– 2HRInt.0HRExt.

ExteriorWalls– 2HRInt.0HRExt.

ExteriorWalls– 2HRInt.1HRExt.

ChoosingFireRatedAssembliesCommontestedassemblies(ASTME119)perIBC703.2:• ULListings• GypsumCatalog• ProprietaryManufacturerTests• IndustryDocuments:suchasAWC’sDCA3

AlternateMethodsperIBC703.3• PrescriptivedesignsperIBC721.1• CalculatedFireResistanceperIBC

722• Fire-resistancedesignsdocumented

insources• Engineeringanalysisbasedona

comparison• Fire-resistancedesignscertifiedby

anapprovedagency

ExteriorWalls– StructuralStability

705.6StructuralStability:ThewallshallextendtotheheightrequiredbySection705.11andshallhavesufficientstructuralstabilitysuchthatitwillremaininplaceforthedurationoftimeindicatedbytherequiredfire-resistancerating.Whereexteriorwallshaveaminimumfireseparationdistanceofnotlessthan30feet(9144mm),interiorstructuralelementswhichbracetheexteriorwallbutwhicharenotlocatedwithintheplaneoftheexteriorwallshallhavetheminimumfire-resistanceratingrequiredinTable601forthatstructuralelement.Structuralelementswhichbracetheexteriorwallbutarelocatedoutsideoftheexteriorwallorwithintheplaneoftheexteriorwallshallhavetheminimumfire-resistanceratingrequiredinTables601and602fortheexteriorwall.

ExteriorWalls– VerticalOffsets

NolessthanSameratingaswallabove

Exteriorwall

Exteriorwall

Thereisnorequirementforanexteriorwalltoextendtothefoundationinasteppedbuilding.

Posts,beamsorwalls,thatsupportaratedexteriorwallmustbefire–resistanceratednotlessthantheratingofthesupportedwall(IBC704.1)

ExteriorWalls– AdditionofWSP

CanincludeWSPinassemblieswhichweretestedwithoutthem:

• ESR2586• AWC’sDCA4

• GypsumAssociationManual

GAFireResistanceDesignManualitem23inSection1oftheGeneralExplanatoryNotes:"Whennotspecifiedasacomponentofafire- resistanceratedwallorpartitionsystem,woodstructuralpanelsshallbepermittedtobeaddedtooneorbothsides.”

ESR2586:

ExteriorWalls– UsingFRTStuds

“Woodstudwallsmaycontainfire-retardant-treatedstudsaswellasuntreatedwoodstuds.Theuseoffire-retardant-treatedplywood(woodstructuralpanels)maybeusedinDesignsthatcontainuseofuntreatedplywoodwhenallotherspecifiedattributesareequivalenttothewoodstructuralpanelusedintheDesign.”

Outline

• Mid-RiseConstructionTypes&LifeSafetyReview• StructuralDesign&DetailingConsiderations• ShrinkageConsiderations&Detailing• AcousticRequirements&Detailing• FireResistiveRequirementsandDetailing

• ExteriorWalls• FloortoWallDetailing• InteriorWalls• ShaftWalls• Corridors&Balconies

Key Differences in Fire Ratings for Construction Types

IIIA IIIB VA

Exterior (bearing) wall framing FRT FRT non-FRT

Exterior wall fire rating 2 hr 2 hr 1 hr

Floor assembly fire rating 1 hr 0 hr 1 hr

Fire wall rating 3 hr 3 hr 2 hr

IntersectionofAssemblies- Ratings

IBCTables601&706.4Note:FRT=FireRetardantTreated

IntersectionofTestedAssemblies2Ho

urW

all

IntersectionofTestedAssemblies

1HourFloor

IntersectionofTestedAssemblies• Manyoptionsareavailableforfireresistance

testedfloorassembliesandwallassemblies• Notestedintersectiondetailsexist• Wemustunderstandtheintent ofthecode,

providearationalethatmeetsthecode’sintent,andutilizeavailableinformationandtestingresults

2HourWall

1HourFloor

2HourWall

TypeIIIExteriorWalls– FRT

TypeIIIandIVConstruction- IBCSection602.3:Fire-retardant-treatedwoodframingcomplyingwithSection2303.2shallbepermittedwithinexteriorwallassembliesofa2-hourratingorless

WhatdoesthisFRTWrequirementinclude?• WallFraming(Studs&Plates)– Yes• WallSheathing– YesFloorsheathing?RimJoist?FloorJoists?Everythingintheplaneofthewall?Oronlywallframing?

ExteriorWalls– IntersectingFloors

SomejurisdictionsinterprettheallowanceofFRTframing inexteriorwallsoftypeIIIconstructionasnotincludingFRTwallsheathing.TheinclusionofwallsheathingisintendedintheallowanceofFRTframing.

Severalcodechangeproposalsareinplacewhichclarifythis

ExteriorWalls– IntersectingFloors

Pleasenotethatthefollowingdetailsareexamplesofwhatwehaveseenusedonprojectsanddonotnecessarilyrepresentdetailsthatwillbeacceptedandapplicableinalljurisdictionsandtoallprojects.

Thesedetailsarenotintendedasrecommendationsforuniversallyaccepteddetails.Localproductavailabilityandmanufacturerspecificationsshouldalsobeconsideredforeachproject.

TheArchitectofRecordandEngineerofRecordshouldverifyacceptanceofthedetailsusedontheirprojectwithallprovisionsofthebuildingcode,includinglocalamendments,withthelocalAuthorityHavingJurisdiction.

ExteriorWalls– IntersectingFloors

UntreatedorFRT

FRTWood

LegendFloorsheathing

FRTsheathing

Rationalefordetailapproval:• Intersectionofratedassemblies

(wall&floor)consideredsufficient

TypeIIIConstruction– 2HRWall,1HRFloorTypicalPlatformFraming

Rimjoist

Considerations:• Shrinkageof

rim,plates,joists

• Protectionofrimforfire

FloorJoistOptions:• SolidSawn• Trusses• I-Joists

ExteriorWalls– IntersectingFloors

UntreatedorFRT

FRTWood

LegendFloorsheathing

FRTsheathing

Rationalefordetailapproval:• Membranesonbothsideofwallprovidefire

resistanceviatheirapprovedassembly;atfloorcavity,ceilingprovides1hour,1layerofblockingprovides2nd hr throughcharcalculations

TypeIIIConstruction– 2HRWall,1HRFloorTypicalPlatformFraming

Rimjoist

Blockingbetweenfloorjoists

Considerations:• Shrinkagein

rim,floorjoists,wallplates

FloorJoistOptions:• SolidSawn• Trusses• I-Joists

ExteriorWalls– IntersectingFloors

UntreatedorFRT

FRTWood

LegendFloorsheathing

FRTsheathing

Rationalefordetailapproval:• Membranesonbothsideofwallprovidefire

resistanceviatheirapprovedassembly;atfloorcavity2layersofblockingprovide2hrprotectionthroughcharcalculations

TypeIIIConstruction– 2HRWall,1HRFloorTypicalPlatformFraming

Rimjoist

Blockingbetweenfloorjoists

Considerations:• Shrinkagein

rim,floorjoists,wallplates

FloorJoistOptions:• SolidSawn• Trusses• I-Joists

ExteriorWalls– IntersectingFloors

UntreatedorFRT

FRTWood

Legend

FloorsheathingFRTsheathing

SolidWood/GlulamRimSection

Joisthanger

TypeIIIConstruction– 2HRWall,1HRFloorModifiedPlatformFraming

Rationalefordetailapproval:• Membranesonbothsideofwallprovidefire

resistanceviatheirapprovedassembly;atfloorcavity4xrimprovides2hr protectionthroughcharcalculations

Considerations:• Shrinkagein

rim,floorjoists,wallplates

FloorJoistOptions:• SolidSawn• Trusses• I-Joists

CalculatedFireResistanceofWood

ForExposedWoodMembers:IBC722.1ReferencesAWC’sNDSChapter16(AWC’sTR10isadesignaidtoNDSChapter16)

EquationsforCalculatingFireEndurance• Assumptions• Nominalassumedcharrate=1.5”/hr.• Usesultimatestrengthfordesigncheck

• Structurallyspanningmembers:reducedsectioncheckedforcapacityvs.demand

Source:AWC’sTR10

CHARSLOWSWITHTIME-NONLINEAR

βeff = Effectivecharrate(in/hr),adjustedforexposuretime,t

βn = Nominalcharrate(in/hr),linearcharratebasedona1-hourexposure(1.5”/hr.)

t = Exposuretime(hrs)

187.0

2.1t

neff

ββ =

ACCOUNTSFORNON-CHARREDSTRENGTHRED’N

EquationsforCalculatingFireEndurance

ExteriorWalls– IntersectingFloors

Floorsheathing

FloorJoistOptions• DeepI-joist• HungParallel

ChordTruss

FRTsheathing

SolidWood/Glula

mRimSection

Joisthanger

TypeIIIConstruction– 2HRWall,1HRFloorModifiedPlatformFraming

UntreatedorFRT

FRTWood

Legend

Rationalefordetailapproval:• Membranesonbothside

ofwallprovidefireresistanceviatheirapprovedassembly;atfloorcavity4xrimprovides2hr protectionthroughcharcalculations

Untreated

ExteriorWalls– IntersectingFloors

Floorsheathing

FRTsheathing

Joisthanger

UntreatedorFRT

FRTWood

LegendTypeIIIConstruction– 2HRWall,1HRFloor

Semi-BalloonFraming

Rationalefordetailapproval:• Intersectionofrated

assemblies(wall&floor)consideredsufficient

UntreatedFloorJoistOptions:• SolidSawn• Trusses• I-Joists

Blocking

ExteriorWalls– IntersectingFloors

Floorsheathing

FRTsheathing

Blocking Joisthanger

UntreatedorFRT

FRTWood

LegendTypeIIIConstruction– 2HRWall,1HRFloorSemi-BalloonFramingw/Add’l FireProtection

Rationalefordetailapproval:• Ceilingmembrane

provides1hr protection;Blockinginwallprovides2nd hr throughcharcalculations

UntreatedFloorJoistOptions:• SolidSawn• Trusses• I-Joists

ExteriorWalls– IntersectingFloors

Floorsheathing

FRTsheathing

Blocking

TopflangeJoisthanger

2xblocking UntreatedorFRT

FRTWood

LegendTypeIIIConstruction– 2HRWall,1HRFloorSemi-BalloonFramingw/Add’l FireProtection

Rationalefordetailapproval:• Ceilingmembrane

provides1hr protection;Blockingbetweenjoistsprovides2nd hr throughcharcalculations

UntreatedFloorJoistOptions:• SolidSawn• Trusses• I-Joists

ExteriorWalls– IntersectingFloors

Floorsheathing

FRTsheathing

Blocking

TopflangeJoisthanger

UntreatedorFRT

FRTWood

LegendTypeIIIConstruction– 2HRWall,1HRFloorSemi-BalloonFramingw/Add’l FireProtection

Rationalefordetailapproval:• Ceilingmembrane

provides1hr protection;1layerofwallmembraneprovides2nd hr

UntreatedFloorJoistOptions:• SolidSawn• Trusses• I-Joists

ExteriorWalls– IntersectingFloors

Floorsheathing

FRTsheathing

Blocking

TopflangeJoisthanger

UntreatedorFRT

FRTWood

LegendTypeIIIConstruction– 2HRWall,1HRFloorSemi-BalloonFramingw/Add’l FireProtection

Rationalefordetailapproval:• 1layerofwallmembrane

provides1hr protection;blockingbetweenjoistsprovides2nd hr throughcharcalculations

Blocking

UntreatedFloorJoistOptions:• SolidSawn• Trusses• I-Joists

ExteriorWalls– IntersectingFloors

Floorsheathing

FRTsheathing

TopflangeJoisthangerapprovedtospan2layersGWB

UntreatedorFRT

FRTWood

LegendTypeIIIConstruction– 2HRWall,1HRFloorSemi-BalloonFramingw/Add’l FireProtection

Rationalefordetailapproval:• Membranesonbothside

ofwallprovidefireresistanceviatheirapprovedassembly

UntreatedFloorJoistOptions:• SolidSawn• Trusses• I-Joists

OverGypsumHangers

CommonlycalledFireWallorDrywallHangers

OverGypsumHangers

TopFlangeHangers&FaceMountHangersAvailable

ExteriorWalls– IntersectingFloors

Point#1ofInterpretation:Continuityof2hfirerating•

•Floorsheathing

FRTsheathing

Ledger(depthvaries)

TopflangeJoisthangerBlocking

UntreatedorFRT

FRTWood

LegendTypeIIIConstruction– 2HRWall,1HRFloor

Semi-BalloonFramingw/Ledger

Rationalefordetailapproval:• Membranesonbothsideof

wallprovidefireresistanceviatheirapprovedassembly;atfloorceilingmembraneprovides1hr;blockingprovides2nd hr&maintainsFRTcontinuity

Thisdetailisoftenusedwithabalcony– ledgeristhru-bolted

UntreatedFloorJoistOptions:• SolidSawn• Trusses• I-Joists

Point#1ofInterpretation:Continuityof2hfirerating•

•Floorsheathing

FRTsheathing

Blocking

(2)2xflatblockingUntreatedorFRT

FRTWood

Legend

TypeIIIConstruction– 2HRWall,1HRFloorPlatformFramingw/TopChordBearing

Shouldspecifytrusswebholdback(3/4”

min.)toallowgypsuminstallation

ExteriorWalls– IntersectingFloors

Rationalefordetailapproval:• Membraneson

bothsideofwallprovidefireresistanceviatheirapprovedassembly;atfloorcavityceilingmembraneprovides1hr;1layerofwallmembraneprovides2nd hr

Untreated

Point#1ofInterpretation:Continuityof2hfirerating•

•Floorsheathing

FRTsheathing

Blocking

(2)2xflatblocking

TypeIIIConstruction– 2HRWall,1HRFloorPlatformFramingw/TopChordBearing

Shouldspecifytrusswebholdback(3/4”

min.)toallowgypsuminstallation

ExteriorWalls– IntersectingFloors

Rationalefordetailapproval:• Membraneson

bothsideofwallprovidefireresistanceviatheirapprovedassembly;atfloorcavityblockinginwallprovides1hr;1layerofwallmembraneprovides2nd hr

UntreatedorFRT

FRTWood

Legend

Untreated

Point#1ofInterpretation:Continuityof2hfirerating•

•Floorsheathing

FRTsheathing

Blocking

TypeIIIConstruction– 2HRWall,1HRFloorPlatformFramingw/TopChordBearing

ExteriorWalls– IntersectingFloors

Rationalefordetailapproval:• Membraneson

bothsideofwallprovidefireresistanceviatheirapprovedassembly;atfloorcavityblockinginwallprovides1hr;1layerofwallmembraneprovides2nd hr

UntreatedorFRT

FRTWood

Legend

Untreated

Topflangetrusshanger

Point#1ofInterpretation:Continuityof2hfirerating•

Floorsheathing

FRTsheathing

(2)2xflatblocking

ExteriorWalls– IntersectingFloorsTypeIIIConstruction– 2HRWall,1HRFloorPlatformFramingw/TopChordBearing

Shouldspecifytrusswebholdback(1-

1/2”min.)toallowgypsuminstallation

Rationalefordetailapproval:• Membranes

onbothsideofwallprovidefireresistanceviatheirapprovedassembly

UntreatedorFRT

FRTWood

Legend

Untreated

Point#1ofInterpretation:Continuityof2hfirerating•

•Floorsheathing

FRTsheathing

Blocking

2xrimUntreatedorFRT

FRTWood

Legend

ExteriorWalls– IntersectingFloorsTypeIIIConstruction– 2HRWall,1HRFloorPlatformFramingw/TopChordBearing

Shouldspecifytrusswebholdback(1-

1/2”min.)toallowgypsuminstallation

Rationalefordetailapproval:• Membranes

onbothsideofwallprovidefireresistanceviatheirapprovedassembly

Notereducedtrussbearinglength

Untreated

ExteriorWalls– IntersectingFloors

ExteriorWalls– IntersectingFloors

Gapsbtwnendoftrussmembersandwalltoallowgypsuminstallafter

Floorsheathing

FRTsheathing

(2)2xflatblocking

ExteriorWalls– IntersectingFloorsTypeIIIConstruction– 2HRWall,1HRFloor

PlatformFramingw/TopChordBearing/Ledger

Shouldspecifytrusswebholdbackto

allowledgerinstallation (2)2xledger

Rationalefordetailapproval:• Membraneson

bothsideofwallprovidefireresistanceviatheirapprovedassembly;attopchords,ledger&sheathingprovidecontinuity

UntreatedorFRT

FRTWood

Legend

Untreated

Sheathing

Floorsheathing

FRTsheathing

ExteriorWalls– IntersectingFloorsTypeIIIConstruction– 2HRWall,1HRFloorPlatformFramingw/TopChordBearing

UntreatedorFRT

FRTWood

Legend

Untreated

Rationalefordetailapproval:• Intersectionof

ratedassemblies(wall&floor)consideredsufficient

2xribbon

Floorsheathing

FRTsheathing

ExteriorWalls– IntersectingFloorsTypeIIIConstruction– 2HRWall,1HRFloorPlatformFramingw/TopChordBearing

UntreatedorFRT

FRTWood

Legend

Untreated

Rationalefordetailapproval:• Membraneson

bothsideofwallprovidefireresistanceviatheirapprovedassembly;atfloorcavityblockinginwallprovides1hr;ceilingprovides2nd hr

Blockingbetweenfloortrusses

2xribbon

Floorsheathing

FRTsheathing

ExteriorWalls– IntersectingFloorsTypeIIIConstruction– 2HRWall,1HRFloorPlatformFramingw/TopChordBearing

Rationalefordetailapproval:• Membranes

onbothsideofwallprovidefireresistanceviatheirapprovedassembly

InfillWallFramingBetweenTrusses

WallGypsumExtendstoUndersideofFloorSheathingBetweenTrusses

UntreatedorFRT

FRTWood

Legend

Untreated

ExteriorWalls– IntersectingFloors

ExteriorWalls– Bearingvs.Non-Bearing

Non-bearingExteriorWalls

PerimeterStructuralBeams

Utilizationofstructuralbeamsin-boardordirectlyoverexteriorwallscanmakewallsnon-bearingandreducerequiredfireresistanceratingto1HRor0HR(IBCTable602)Note:Beams&Columnswillmostlikelybeconsidered“PrimaryStructuralFrame”&requireindividualencasementperIBC704

FloorFraming

PerimeterStructuralColumns

ExteriorWalls– Bearingvs.Non-Bearing

Ifframingparalleltolongexteriorwallsispossible,minimizesareaofloadbearingexteriorwalls

TypeIIIConstructionDetailExamples

Whatisbeingenforcedinjurisdictionsyouareworkingin?

Outline

• Mid-RiseConstructionTypes&LifeSafetyReview• StructuralDesign&DetailingConsiderations• ShrinkageConsiderations&Detailing• AcousticRequirements&Detailing• FireResistiveRequirementsandDetailing

• ExteriorWalls• FloortoWallDetailing• InteriorWalls• ShaftWalls• Corridors&Balconies

InteriorFire-RatedWalls:Differences

Firewalls

• BuildingSeparation

• Openingsareprotected

• Continuousfromfoundationto/throughroof

• Structuralstability

FireBarrier

• Shafts,OccupancySeparation

• Continuousfromfloorthroughconcealedspace

FirePartition:

• DwellingUnitSeparation;Corridors

• Openingsareprotected

• Mayterminateatafireratedfloor/celiling/roofassembly

FireWalls– Ratings&Materials

IBC706.3– Firewallsshallbeofanyapprovednon-combustiblematerials.

Exception:BuildingsofTypeVconstruction

FireWalls– Ratings&Materials

OpportunityforWoodFramedFireWalls:• PermittedintypeVConstruction• FireWallsintypeVConstructionofA,B,E,Rand

severalotheroccupanciesmaybe2hourFireWallsintypeIIIandIVconstructionarerequiredtobeconstructedofnon-combustiblematerials• Opportunityforwoodframebearingwallsoneach

sideoffirewalltomeetstructuralstabilityrequirements

FireWalls– StructuralStability

706.2StructuralStability:Firewallsshallhavesufficientstructuralstabilityunderfireconditionstoallowcollapseofconstructiononeithersidewithoutcollapseofthewallforthedurationoftimeindicatedbytherequiredfire-resistanceratingorshallbeconstructedasdoublefirewallsinaccordancewithNFPA221.

2HourFireWallAssembly

2"HOUR DOUBLE STUD WALL

2 X FRAMING AT 16" O.C.

2"HOUR RATING PER GA FILE NO. WP 3820

WOOD STRUCTURAL PANELS WHEREREQUIRED FOR SHEAR

RESILIENT DRAFT STOPS ATMAX. 10' O.C. HORIZONTAL

2 LAYERS 5/8" TYPE 'X' GYPSUMBOARD EACH SIDE

BATT INSULATION AS REQUIRED FOR THERMAL/ACOUSTICALPERFORMANCE

AIR

GAP

0' "

1"

ConstructionType:• V

2HourFireWallAssembly

ConstructionType:• V

2HourFireWallAssembly

ConstructionTypes:• III• IV• V

AlsoseeULU336

2HourFireWallAssembly

2"HOUR FIRE WALL ASSEMBLY

2 1/2" METAL STUDS AT 24" O.C.

2 LAYERS 5/8" TYPE 'X' GYP. BD. ON EACH SIDE OF METAL STUDS

WOOD STRUCTURAL PANELS WHERE REQUIRED FOR SHEAR

2"HOUR RATING PER GA FILE NO. WP 1548

WOOD STUD WALLS ON EITHERSIDE OF FIRE WALL

AIR

GA

P

0' "

1"

AIR

GA

P

0' "

1"

INTERIOR OR EXTERIOR FINISH AS REQUIRED

BATT INSULATION (OPTIONAL)

CAD&RevitDetails:www.woodworks.org

ConstructionTypes:• III• IV• V

GAWP1548ULU411

2HourFireWallAssembly

2"HOUR FIRE WALL AT FLOOR/CEILING

2"HR. ASSEMBLY: 2 1/2" METALSTUDS WITH 2 LAYERS 5/8" TYPE 'X'

GYP. BD. EACH SIDE

CONTINUOUS STRUCTURAL WOODPANELS " USE FIRE"TREATED PANELS

THROUGH WALL CAVITY¹

¹CONSULT LOCAL JURISDICTION HAVING AUTHORITY FOR ACCEPTANCE OF FIRE"TREATED WOODPANELS RUNNING THROUGH 2"HOUR ASSEMBLY IN THIS APPLICATION.

RIM JOIST WITH SOLID BLOCKING

2"HOUR FIRE CAULKING

1" AIR GAP

RESILIENT CHANNELS

2 X 4 STUD WALL EACH SIDE, WITHSTRUCTURAL WOOD PANELS AS

REQUIRED FOR SHEAR AND 1 LAYER5/8" TYPE 'X' GYP. BD.

SAWN LUMBER FRAMING WITH WOOD PANEL DIAPHRAGM RUNNING THROUGH FIRE WALL

CAD&RevitDetails:www.woodworks.org

ConstructionTypes:• III• IV• V

GAWP1548ULU411

2HourFireWallAssembly

ConstructionTypes:• III• IV• V

Caninstallwoodbearingwalloneachsideof2hourwall

3HourFireWallAssembly

3"HOUR FIRE WALL ASSEMBLY

1 5/8" METAL STUDS AT 24" O.C. MAX.

3 LAYERS 1/2" TYPE 'X' GYP. BD. ON EACH SIDE OF METAL STUDS

WOOD STRUCTURAL PANELS WHERE REQUIRED FOR SHEAR

3 HOURS PER UL DESIGN NO. U435

WOOD STUD WALLS ON EITHERSIDE OF FIRE WALL

AIR

GAP

0' "

1"

AIR

GAP

0' "

1"

INTERIOR OR EXTERIOR FINISH AS REQUIRED

BATT INSULATION (OPTIONAL)

ConstructionTypes:• III• IV• V

3HourFireWallAssembly

• (2)1”TypeXGypsum• 2”HStuds• 2”mineralfiberinsulation

eachside

ConstructionTypes:• III• IV• V

Couldinstallwoodbearingwalloneachsideof3hourwall

3HourFireWallAssembly

Couldinstallwoodbearingwalloneachsideof3hourwall

FireWalls– SeismicDiaphragmContinuity

CAD&RevitDetails:www.woodworks.org

3"HOUR FIRE WALL AT FLOOR/CEILING

3"HR. ASSEMBLY: 1 5/8" METALSTUDS WITH 3 LAYERS 1/2" TYPE 'X'

GYP. BD. EACH SIDE

3"HOUR FIRE CAULKING

1" AIR GAP

RESILIENT CHANNELS

2 X 4 STUD WALL EACH SIDE, WITHSTRUCTURAL WOOD PANELS AS

REQUIRED FOR SHEAR AND 1 LAYER5/8" TYPE 'X' GYP. BD.

CONTINUOUS 13 1/2" WIDE 14 GA. GALV.SHT. METAL

CONTINUOUS 16 GA. TRACK TOP ANDBOTTOM

FIRE SAFING

CONTINUOUS 16 GA. COMP. CHANNEL

WOOD TRUSS FRAMING WITHOUT WOOD PANEL DIAPHRAGM RUNNING THROUGH FIRE WALL3"HOUR FIRE WALL AT FLOOR/CEILING

3"HR. ASSEMBLY: 1 5/8" METALSTUDS WITH 3 LAYERS 1/2" TYPE 'X'

GYP. BD. EACH SIDE

CONTINUOUS STRUCTURAL WOODPANELS " USE FIRE"TREATED PANELS

THROUGH WALL CAVITY¹

¹CONSULT LOCAL JURISDICTION HAVING AUTHORITY FOR ACCEPTANCE OF FIRE"TREATED WOODPANELS RUNNING THROUGH 3"HOUR ASSEMBLY IN THIS APPLICATION.

RIM JOIST WITH SOLID BLOCKING

3"HOUR FIRE CAULKING

1" AIR GAP

RESILIENT CHANNELS

2 X 4 STUD WALL EACH SIDE, WITHSTRUCTURAL WOOD PANELS AS

REQUIRED FOR SHEAR AND 1 LAYER5/8" TYPE 'X' GYP. BD.

I"JOIST FRAMING WITH WOOD PANEL DIAPHRAGM RUNNING THROUGH FIRE WALL

FireWalls– SeismicDiaphragmContinuity

FireBarriers– IBC707

Commonlyusedin:• Shaftenclosures• Interiorexitstairway• Exitstairwayenclosures• Exitpassageways• Incidentaluses• Separatedoccupancies• FireAreas

2012IBCCode&Commentary

FireBarrierExample

FireBarriers– IBC707FireBarriers:§ Maybeconstructedwithanymaterialspermittedbythe

constructiontype§ FireResistanceRatings:• ShaftEnclosures:IBC713.4

• 2Hr whenconnecting4storiesormore,1hr ifless• SeparatedOccupancies:IBCTable508.4• FireAreas:IBCTable707.3.10

FireBarriers– IBC707

707.5:Continuity:Firebarriersshallextendfromthetopofthefoundationorfloor/ceilingassemblybelowtotheundersideofthefloororroofsheathing,slabordeckaboveandshallbesecurelyattachedthereto.Suchfirebarriersshallbecontinuousthroughconcealedspace,suchasthespaceaboveasuspendedceiling

707.5.1SupportingConstruction:Thesupportingconstructionforafirebarriershallbeprotectedtoaffordtherequiredfire-resistanceratingofthefirebarriersupported.Hollowverticalspaceswithinafirebarriershallbefireblocked inaccordancewithSection718.2ateveryfloorlevel.

Otherrequirementsforopenings,penetrations,joints

FireBarriers– IBC707

CommonDetailingMethod:FireBarrier&membraneextendtoundersideoffloordeckabove

FirePartitions– IBC708

Commonlyusedtoseparate:• Dwellingorsleeping

unitsinsamebldg.• Tenantspacesinmalls• CorridorwallsMinimum1hr ratingexcept:• Somecorridors• Separatedwellingunits

inVBandIIB

2012IBCCode&Commentary

FirePartitionExample

FirePartitions– IBC708FirePartitions:§ Maybeconstructedwithanymaterialspermittedbythe

constructiontype§ 708.3FireResistanceRatings:• Firepartitionsshallhaveafire-resistanceratingofnotless

than1hour.Exceptions:1.Corridorwallspermittedtohavea1/2 hourfire-resistanceratingbyTable1018.1.2.DwellingunitandsleepingunitseparationsinbuildingsofTypeIIB,IIIBandVBconstructionshallhavefire-resistanceratingsofnotlessthan1/2 hourinbuildingsequippedthroughoutwithanautomaticsprinklersysteminaccordancewithSection903.3.1.1.

FirePartitions– IBC708708.4Continuity.Firepartitionsshallextendfromthetopofthefoundationorfloor/ceilingassemblybelowtotheundersideofthefloororroofsheathing,slabordeckaboveortothefire-resistance-ratedfloor/ceilingorroof/ceilingassemblyabove,andshallbesecurelyattachedthereto.Incombustibleconstructionwherethefirepartitionsarenotrequiredtobecontinuoustothesheathing,deckorslab,thespacebetweentheceilingandthesheathing,deckorslababoveshallbefireblocked ordraftstopped inaccordancewithSection718.2and718.3atthepartitionline.Thesupportingconstructionshallbesupportedtoaffordtherequiredfire-resistanceratingofthewallsupported,exceptfor...wallsseparatingdwellingunits,wallsseparatingsleepingunits,andcorridorwalls,inbuildingsofTypeIIB,IIIBandVBconstruction.

FirePartitions– IBC707

CommonDetailingMethod:FirePartition&membranestopatundersideofratedfloor/ceilingwithfireblocking/draftstopping ifrequired

Outline

• Mid-RiseConstructionTypes&LifeSafetyReview• StructuralDesign&DetailingConsiderations• ShrinkageConsiderations&Detailing• AcousticRequirements&Detailing• FireResistiveRequirementsandDetailing

• ExteriorWalls• FloortoWallDetailing• InteriorWalls• ShaftWalls• Corridors&Balconies

Detailing:ShaftWallsvs.ExteriorWalls

IBC713.2:ShaftWallsshallbeconstructedasFireBarriers

KeyDifferencesbetweenExteriorWallsandShaftWalls(FireBarriers)• Continuity• SupportingConstruction• FireResistanceRatings• ConstructionMaterials

Detailing:ShaftWallsvs.ExteriorWalls

ShaftWallRequirements:

707.5:FireBarrierContinuity:• Mustextendfromtopofthefoundationorfloor/ceiling

assemblybelowtotheundersideofthefloororroofsheathing

• Throughconcealedspaces

707.5.1:SupportingConstruction:• Thesupportingconstructionfora

firebarriershallbeprotectedtoaffordtherequiredfire-resistanceratingofthefirebarriersupported.

Detailing:ShaftWallsvs.ExteriorWalls

ShaftWallRequirements:

713.4Fire-ResistanceRating:• 2hours(4storiesormore)• 1hour(lessthan4stories)• Numberofconnectedstoriesincludesbasementbutnot

mezzanine• Fireratingshallnotbelessthanfloorassemblypenetrated,

butneednotexceed2hours

707.2:ConstructionMaterials:• Anypermittedbyconstructiontype• FRTWnotrequiredforshaftwallsintypesIII,IV,V

Detailing:ShaftWallsvs.ExteriorWalls

Howdoweachievetheserequirements?

Continuity:Thegeneralrequirementsin707.5werenotwrittenwithplatformconstructioninmind...theywereattemptingtoprecludelargeopenconcealedspacestoprovideacontinuousbarrierbetweenoneportionofthebuildingandanother

Manyjurisdictionshaverecognizedthatcontinuityofthefirebarrier’sfireprotectioncanbemaintainedevenifthewallframing doesnotextendtotheundersideofthedeckingabove

Detailing:ShaftWallsvs.ExteriorWalls

SupportingConstruction:Musthavesamefireresistanceratingasfirebarrierbeingsupported

Detailing:ShaftWallsvs.ExteriorWalls

SupportingConstruction:Inplatformandsemi-balloonframeconstruction,ifwehavea2hourshaftwallanda1hourfloor,howdoweachievethis?Ifweareabletodemonstratethewall’s2hourcontinuity,shouldnotneedtoconsiderthefloor“supportingconstruction”?

1HourFloor

2HourWall

Detailing:ShaftWallsvs.ExteriorWalls

TypesofShafts:• Elevator• Stair• Mechanical

Somepointsofshaftwallconstructionapplytoanytypeofshaft.Someareuniquetoeachtypeofshaft.

ShaftWalls

ShaftWalls

MasonryShaftWalls

MasonryShaftWalls

MasonryShaftWalls

MasonryShaftWalls

Mixingmasonryshaftwallswithwoodfloorframingcancreateseveralissues:• Masonryshaftwallscanbecomepartofbuilding’s

lateralforceresistingsystem,increasingseismicforcesandaddingmass

• Differentialshrinkagebetweenwoodandmasonry

• Bestpracticesincludeseismicallyisolatingmasonryshaftwalls,onlytiewoodfloortomasonryshaftwhererequired(i.e.atelevatordoorthreshold)

MasonryShaftWalls

CMUshaftwall

MasonryShaftWallDetail

Floorframingandwoodbearingwalls

MasonryShaftWalls

CMUshaftwall

MasonryShaftWallDetail

Floorbeam,joists&sheathing

ShaftWallMaterialChoice

Whydoweintroducenewmaterialsforourshaftwalls?Theycanbeframedwithwood!

WoodFramedShaftWalls

WoodFramedShaftWalls

Usingwoodframedshaftwallscan:• Eliminatelateralloadconsiderationsassociatedwithattaching

wooddiaphragmstoconcreteormasonryshaftwalls(SDPWS4.1.5)

• Eliminatedifferentialshrinkageatfloortowalltransition• Eliminatedifferentconstructiontradesinbuildingduring

construction• Reducecosts• Improveschedule

ShaftWallDetails

WoodDesignFocus:Volume22,Issue3bySmith

Rimjoist

Floorjoists

2layers5/8”thk.Type“X”GWBeachsidefor2hr.rating(ULU301)

2xstudsDbl.rowofsolidblockingtocontinuefirerating

WSPsht’gasrequired

Concretetopping

Considerations:• Shrinkageinrim&floorjoist• Acoustics

Rationalefordetailapproval:• Membraneson

bothsideofwallprovidefireresistanceviatheirapprovedassembly;atfloorcavity2layersofblockingprovide2hrprotectionthroughcharcalculations

ShaftSide

FloorSide

ShaftWallDetails

Rationalefordetailapproval:• Membranesonbothsidesofwallprovidefire

resistanceviatheirapprovedassemblyandarecontinuous.FRTfloorsheathingcanbeinsuranceforminimalpenetrationofmembrane.

ShaftSide FloorSide

ShaftWallsw/Shaftliner

Rationalefordetailapproval:• Shaftlinerassemblyprovidesfireresistance

independentofframingmaterialoneitherside.

ShaftSide FloorSide

Floorsidewallprovidestypicalfloorsupport

Shaftliner inH-studsattachedtowallwithclips

Shaftsidewallprovidesshaftframing(stair,elevatorrail)support

ShaftWallsw/HStuds&Shaftliner

Source:GeorgiaPacific

Source:USGypsum

ShaftWallsw/HStuds&Shaftliner

SingleWallOption

Source:ULU375DoubleWallOption

ShaftWallsw/HStuds&Shaftliner

HStudAttachmentClips

ExampleShaftliner ClipAttachment ScheduleperULU375SystemNo. SystemHeight

LimitationAttachment ClipSchedule

1 23ft 10ft o.c.2 44ft Baseto20 ft:5ft o.c.

20ft to44ft:10ft o.c.3 66ft Baseto22ft:3’-4”o.c.

22ft to42ft:5ft o.c.42ft to66ft:10ft o.c.

AttachmentClips:Aluminumorsteelangles,usually14– 16gauge,2”widewith2”to2-1/2”longlegs.AttachestowallframingandH-studs

H-StudSource:Clarkdietrich

ShaftWallsw/ShaftlinerCanalsoutilizewoodframedshaftwallson3sidesandCHstudswithshaftliner on4th side

ShaftWallsw/CHorCTStuds2hourwallswithC-HStuds,shaftliner,and

gypsumpanels

ShaftWallsw/CHorCTStuds

ShaftWallsw/CHorCTStuds

Somewallmanufacturerswilllistatotalsystemheightlimitation.Ifthisisnotarequirementofthetestedassembly(i.e.ULorsim.requirement)canalsoperformastructuralanalysisofthewalls,especiallywhenstackingmultiplestories,toverifyadequacy

Source:Clarkdietrich

StairwayShaftEnclosures&FramingWoodFramedWallon

3SidesofShaft

CHStudsw/Shaftlineron4th SideofShaft

ElevatorShaftWalls

ElevatorShaftWalls

WoodFramedElevatorShaftWall

WoodFramedElevatorRailSupports

WoodFramedElevatorRailSupports

WoodFramedElevatorRailDetails

ElevatorShaftWall

WoodDesignFocus:Volume22,Issue3bySmith

Rimjoist

Floorjoists

2layers5/8”thk.Type“X”GWBeachsidefor2hr.rating

Doublestudwall Dbl.rowofsolidblockingtocontinuefirerating

Concretetopping

Nailerplate

WSPsht’gasrequired

Elevatorguiderailsandsupportbracketwithslottedholes

Galvanizedmetalspacer

Considerations:• Shrinkage• Improvedacoustical

performancewithdoublewall

Rationalefordetailapproval:• Membraneson

bothsideofwallprovidefireresistanceviatheirapprovedassembly.2layersof2xblockinginfloorcavitycontinueprotection

ShaftSide FloorSide

Considerations:• Shrinkageinrim&floorjoist/differentialshrinkage• Doublewallprovidesimprovedacoustics

ElevatorShaftWall

Floorjoists

2layers5/8”thk.Type“X”GWBeachsidefor2hr.rating

Doublestudwall

Concretetopping

Nailerplate

WSPsht’g asrequired

Elevatorguiderailsandsupportbracketwithslottedholes

Galvanizedmetalspacer

Rationalefordetailapproval:• Membraneson

bothsideofwallprovidefireresistanceviatheirapprovedassemblyTopflangejoist

hangerapprovedtospan2layersGWB

ShaftSide FloorSide

StairShaftWalls

StairShaftWalls

StairwayShaftEnclosures&Framing

ExteriorBearingWall

IntermediateLandingFramingElev.=94’-8”

CorridorFramingElev.=100’-0”

Floo

rFraming

Elev.=100

’-0”

IndicatesDownwardStairTravelPath

LandingFramingElev.=100’-0”

Floo

rFraming

Elev.=100

’-0” Structural

Beam

ShaftWalls

WoodFramedStairShaftWalls

WoodFramedStairShaftWalls

WoodFramedStairShaftWalls

StairwayShaftEnclosures&Framing

TypicalFloorjoist

StairFraming(Landing&Stringers)

Attachmentofstairframingtoshaftwallthroughgypsum,typically2layers

Shaftwall

Stair&FloorCommonWallDetail

Rationalefordetailapproval:• 2layersofwallmembrane

provide2hr protection

StairwayShaftEnclosures&Framing

TypicalFloorjoist

Shaftwall

Stair&FloorCommonWallDetail

Rationalefordetailapproval:• Membranesonbothsideof

wallprovidefireresistanceviatheirapprovedassembly

IntermediateStairLanding

FramingAttachledgertoeachshaftwallstudwithfasteners(woodscrews,lagscrews)designedtoaccountforgypsum

StairShaftSide

FloorSide

StairwayShaftEnclosures&Framing

StairFraming(Landing&Stringers) Attachmentofstair

framingtoshaftwallthroughgypsum,typically2layers

Shaftwall

Consider“Hinge”atwallplatesforout-of-planewind&seismicloadsduetolackofadjacentfloor:• SpanPlates

Horizontally(nojoints)• Installadditional

member(rim)tospanhorizontally

StairExteriorWallDetail

Rationalefordetailapproval:• 2layersofwallmembrane

provide2hr protection

StairwayShaftEnclosures&Framing

IntermediateStairLanding

WhenStairShaftWallisExteriorWall

WallPlatesatTypicalFloorElevation– CreatesPotential“Hinge”

StairwayShaftEnclosures&Framing

IntermediateStairLanding

Framing Attachledgertoeachshaftwallstudwithfastenersdesignedtoaccountforgypsum

Shaftwall

StairExteriorWallDetail

Rationalefordetailapproval:• Membranesonbothsideof

wallprovidefireresistanceviatheirapprovedassembly

StairShaftSide

ExteriorSideConsider“Hinge”atwallplatesforout-of-planewind&seismicloadsduetolackofadjacentfloor:• Spanplateshorizontally• Installadditional

member(rim)tospanhorizontally

StairwayShaftEnclosures&Framing

StairwayShaftEnclosures&Framing

StairwayShaftEnclosures&Framing

StairwayShaftEnclosures&Framing

IntermediateStairLanding

Framing Attachledgertoeachshaftwallstudwithfastenersdesignedtoaccountforgypsum

Shaftwall

StairExteriorWallDetail

Rationalefordetailapproval:• Membranesonbothsideof

wallprovidefireresistanceviatheirapprovedassembly

StairShaftSide

ExteriorSideConsider“Hinge”atwallplatesforout-of-planewind&seismicloadsduetolackofadjacentfloor:• Installadditional

member(rim)tospanhorizontally

StairwayShaftEnclosures&Framing

StairwayShaftEnclosures&Framing

IntermediateStairLanding

ExteriorWallPlateElevationsShiftedDowntoIntermediate

LandingElevation

• EliminatesHingeEffect• AvoidsInterferencewith

LandingWindows

WhenStairShaftWallisExteriorWall

StairwayShaftEnclosures&Framing

IntermediateStairLanding

Framing Attachledgertoeachshaftwallstudwithfasteners(woodscrews,lagscrews)designedtoaccountforgypsum

Shaftwall Wallplateelevationsshiftedtointermediatelandingelevationatstairshafts

StairExteriorWallDetail

Rationalefordetailapproval:• Membranesonbothsideof

wallprovidefireresistanceviatheirapprovedassembly

StairShaftSide

ExteriorSide

StairwayShaftEnclosures&Framing

IntermediateStairLanding

Framing

Topflangejoisthangerapprovedtospan2layersGWB

ShaftwallWallplateelevationsshiftedtointermediatelandingelevationatstairshafts

StairExteriorWallDetail

Rationalefordetailapproval:• Membranesonbothsideof

wallprovidefireresistanceviatheirapprovedassembly

StairShaftSide

ExteriorSide

StairwayShaftEnclosures&Framing

StairLandingFraming

Attachledgertostudswithfasteners(woodscrews,lagscrews)designedtoaccountfor1layerofgypsum

Shaftwall Blockinginshaftwallbetweenstuds

Wallplatesattypicalfloorelevation

LedgerInterruptsOneLayerofShaft

WallGypsum

StairWallDetail

Rationalefordetailapproval:• Membranesonbothsideof

wallprovidefireresistanceviatheirapprovedassembly;atfloorcavity,blockinginwallprovides2nd hr

StairShaftSide

ExteriorSide

StairwayShaftEnclosures&Framing

StairLandingFraming Attachledgertoblocking

withfasteners(woodscrews,lagscrews)

Shaftwall2layersofblockinginshaftwallbetweenstudstoprovide2hoursprotection&ledgerfastenerattachment

Wallplatesattypicalfloorelevation

StairWallDetail

Rationalefordetailapproval:• Membranesonbothsideof

wallprovidefireresistanceviatheirapprovedassembly;atfloorcavity2layersofblockinginwallprovide2hr protection

StairShaftSide

ExteriorSide

StairwayShaftEnclosures&Framing

IntermediateStairLanding

Framing

Shaftwall Wallplateelevationsshiftedtointermediatelandingelevationatstairshafts

StairExteriorWallDetail

Rationalefordetailapproval:• Membranesonbothsideof

wallprovidefireresistanceviatheirapprovedassembly

StairShaftSide

ExteriorSide

Installspanningbeamjustinboardofshaftwall -onlypenetratewallatendofbeamlocations–requiresintermediateheightposts

FloorBm

StairwayShaftEnclosures&Framing

Wallplateelevationsshiftedtointermediatelandingelevationatstairshafts

StairExteriorWallDetail

Rationalefordetailapproval:• Membranesonbothsideof

wallprovidefireresistanceviatheirapprovedassembly

StairShaftSideExteriorSide

Shaftwall

IntermediateLandingFloorSheathingmayStopatLandingWallifLandingWallisAdequatelyBraced

Landingandstairframingsupportedonindependent

bearingwalls– shouldconsiderlateralbracingof

independentwalls

IntermediateStairLanding

Framing

StairwayShaftEnclosures&Framing

StairFraming(Landing&Stringers)

Landingandstairframingsupportedonindependentbearingwalls– shouldconsiderlateralbracingofindependentwalls

Shaftwall

Wallplatesattypicalfloorelevation

Rationalefordetailapproval:• Membranesonbothsideof

wallprovidefireresistanceviatheirapprovedassembly

StairWallDetail

StairShaftSide ExteriorSide

StairwayShaftEnclosures&Framing

ExteriorBearingWall

LandingFramingElev.=94’-8”

CorridorFramingElev.=100’-0”

Floo

rFraming

Elev.=100

’-0”

IndicatesDownwardStairTravelPath

LandingFramingElev.=100’-0”

Floo

rFraming

Elev.=100

’-0”

IntermediateLandingBeamConcentratedLoad

StairwayShaftEnclosures&Framing

IntermediateStairLanding

Framing

Shaftwall

StairExteriorWallDetail

Rationalefordetailapproval:• Membranesonbothsideof

wallprovidefireresistanceviatheirapprovedassembly;atfloorcavitybeamoversizedtoprovide2hourcharprotection

StairShaftSide

ExteriorSide

IntermediateLandingBeamExtendsintoShaftWall– OversizetoProvide2HourFireProtectionUsingCalculatedCharRates

StairwayShaftEnclosures&Framing

2Hr protectionprovidedall

aroundbeamvia.blocking

Beambearsdirectlyonaxiallyloadedpost–shrinkageconcernsareminimized

Outline

• Mid-RiseConstructionTypes&LifeSafetyReview• StructuralDesign&DetailingConsiderations• ShrinkageConsiderations&Detailing• AcousticRequirements&Detailing• FireResistiveRequirementsandDetailing

• ExteriorWalls• FloortoWallDetailing• InteriorWalls• ShaftWalls• Corridors&Balconies

Corridors– FireResistanceRatings

CheckrequirementsofIBCTables601and1018.1forCorridorWallandFloor/CeilingFire-ResistanceRatings

Corridors– FireResistanceRatings

CorridorWalls

IBC1018.1:Corridorwallsrequiredtobefire-resistanceratedshallcomplywithSection708forfirepartitions.

708.3Fire-resistancerating.Firepartitionsshallhaveafire-resistanceratingofnotlessthan1hour.

Exception:Corridorwallspermittedtohavea1/2hourfire-resistanceratingbyTable1018.1(appliestoRoccupancieswithsprinklersystems)

CorridorWalls708.4Continuity.Firepartitionsshallextendfromthetopofthefoundationorfloor/ceilingassemblybelowtotheundersideofthefloororroofsheathing,slabordeckaboveortothefire-resistance-ratedfloor/ceilingorroof/ceilingassemblyabove,andshallbesecurelyattachedthereto.Exceptions:2.Wheretheroom-sidefire-resistance-ratedmembraneofthecorridoriscarriedthroughtotheundersideofthefloororroofsheathing,deckorslabofafire-resistance-ratedfloororroofabove,theceilingofthecorridorshallbepermittedtobeprotectedbytheuseofceilingmaterialsasrequiredfora1-hourfire-resistance-ratedfloororroofsystem.3.Wherethecorridorceilingisconstructedasrequiredforthecorridorwalls,thewallsshallbepermittedtoterminateattheuppermembraneofsuchceilingassembly.

CorridorWalls– 708.4Exception2

CorridorWalls– 708.4Exception3

• 1”gypsumunderlayment• 19/32”WSP• 3½”FiberglassBatt• 2x10joists@24“oc• Resilientchannel• 5/8”Type-XGyp

Corridors- 1hrFloor

ULL502GAFC5104

Corridordecking

Floorsheathing

Joisthangerifjoistsperpendiculartowall

Corridors- 1hrFloor

Untreated

FRTWood

Legend

Thinnerframingwithdroppedceilingallowsmainmechanicallinestorunincorridor

Balconies– IBC1406.3

BalconiesofcombustibleconstructionandnotFRTshallbe:• Ratedinaccordancew/Table601forfloors• OrbeofTypeIV• Andshallnotexceed50%ofbldgperimeterExceptions• BalconiesinTypeIII,IVandVcanbeoftypeV

constandshallnothavefireresistanceratingifsprinklerprotectionprovided

• Untreatedwoodispermittedforrailsandguardrails

Balconies– IBC1406.3

So….ForTypeIIIorVbalconyoptionsare:

1. Non-combustible– nosprinklers/nofirerating2. FRT– nofiresprinklers/nofirerating3. TypeIV– nofiresprinklers/nofirerating4. Nontreated– firesprinkler/nofirerating5. Nontreated– fireratedper601&602/nosprinkler

Balconies– ExteriorWallPenetration

FloorsheathingFRTdecking

TopflangeJoisthangerapprovedtospan2layersGWB

Cantileverbeam

Cantileverknifeplatesupport

Exteriorveneerasoccurs

Caulking,sealantsvaporbarriers,and flashingnotshownforclarity

Questions?

ThisconcludesTheAmericanInstituteofArchitectsContinuingEducationSystemsCourse

Visitwww.woodworks.org formoreeducationalmaterials,casestudies,designexamples,aprojectgallery,andmore

ThispresentationisprotectedbyUSandInternationalCopyrightlaws.

Reproduction,distribution,displayanduseofthepresentationwithoutwrittenpermission

ofthespeakerisprohibited.

©TheWoodProductsCouncil2016

CopyrightMaterials